EZ5 MIB Catalog

ARISTA-LOGMGR-MIB

2024-09-30

Download ARISTA-LOGMGR-MIB.txt Open ARISTA-LOGMGR-MIB.txt in a new tab

The MIB module for managing logging manager statistics on Arista devices.

TABLES (1)

Tables (1)

NameOID
aristaLogForwardingStatsTable1.3.6.1.4.1.30065.3.39.1.1

END OF TOC

Table details

aristaLogForwardingStatsTable

1.3.6.1.4.1.30065.3.39.1.1

Index: aristaLogForwardingStatsIpAddrType · aristaLogForwardingStatsIpAddr · aristaLogForwardingStatsPort

A table that contains log forwarding statistics for each syslog server.

aristaLogForwardingStatsIpAddrType

1.3.6.1.4.1.30065.3.39.1.1.1.1

InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address. unknown(0) An unknown address type. This value MUST be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below. ipv4(1) An IPv4 address as defined by the InetAddressIPv4 textual convention. ipv6(2) An IPv6 address as defined by the InetAddressIPv6 textual convention. ipv4z(3) A non-global IPv4 address including a zone index as defined by the InetAddressIPv4z textual convention. ipv6z(4) A non-global IPv6 address including a zone index as defined by the InetAddressIPv6z textual convention. dns(16) A DNS domain name as defined by the InetAddressDNS textual convention. Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType. To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation. Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32

Logging host IP address family.

aristaLogForwardingStatsIpAddr

1.3.6.1.4.1.30065.3.39.1.1.1.2

InetAddressDenotes a generic Internet address. An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row. The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error. When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING

Logging host IP address.

aristaLogForwardingStatsPort

1.3.6.1.4.1.30065.3.39.1.1.1.3

Unsigned32 (1..65535)

Logging host port number.

aristaLogForwardingStatsProtocol

1.3.6.1.4.1.30065.3.39.1.1.1.4

AristaLogProtocol0 = udp1 = tcp2 = tlsThe protocol used for logging. · Integer32

The protocol used for sending logs to the logging host.

aristaLogForwardingStatsLastRefreshed

1.3.6.1.4.1.30065.3.39.1.1.1.5

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

Timestamp indicating when this entry's statistics were last updated.

aristaLogForwardingStatsBytesSent

1.3.6.1.4.1.30065.3.39.1.1.1.6

Counter64 (0..18446744073709551615)

Total number of bytes sent to the logging host.

aristaLogForwardingStatsProcessed

1.3.6.1.4.1.30065.3.39.1.1.1.7

Counter64 (0..18446744073709551615)

Total number of log messages that were processed for forwarding to the logging host. This count is the sum of the number of messages that were successfully forwarded and the number of messages that were unsuccessfully forwarded (see aristaLogForwardingStatsFailed).

aristaLogForwardingStatsFailed

1.3.6.1.4.1.30065.3.39.1.1.1.8

Counter64 (0..18446744073709551615)

Total number of log messages that were unsuccessfully forwarded to the logging host.

aristaLogForwardingStatsSuspended

1.3.6.1.4.1.30065.3.39.1.1.1.9

Counter64 (0..18446744073709551615)

Total number of times log forwarding was suspended.

aristaLogForwardingStatsSuspendedDuration

1.3.6.1.4.1.30065.3.39.1.1.1.10

Counter64 (0..18446744073709551615)

Total number of seconds log forwarding was suspended.

aristaLogForwardingStatsResumed

1.3.6.1.4.1.30065.3.39.1.1.1.11

Counter64 (0..18446744073709551615)

Total number of times log forwarding was resumed.

↑ To TOC