CISCO-CAT6K-CROSSBAR-MIB

2013-09-16

The Catalyst 6000 Crossbar MIB provides instrumentation for configuration and operation of the crossbar switching fabric module, and additional functionalities for switching bus and internal bus, etc.

Download CISCO-CAT6K-CROSSBAR-MIB.txt Open CISCO-CAT6K-CROSSBAR-MIB.txt in a new tab

SCALARS (39) · TABLES (8) · TRAPS (8)

Scalars (39)

NameOID
cc6kxbarFallbackMode1.3.6.1.4.1.9.9.217.1.1.1
cc6kxbarBusOnlyModeAllowed1.3.6.1.4.1.9.9.217.1.1.2
cc6kxbarTruncatedModeAllowed1.3.6.1.4.1.9.9.217.1.1.3
cc6kxbarMinFabricPresent1.3.6.1.4.1.9.9.217.1.1.4
cc6kxbarTruncatedModeOper1.3.6.1.4.1.9.9.217.1.1.6
cc6kxbarDcefOnlyModeAllowed1.3.6.1.4.1.9.9.217.1.1.7
cc6kxbarForceBusMode1.3.6.1.4.1.9.9.217.1.1.8
cc6kxbarBusOnlyModeOper1.3.6.1.4.1.9.9.217.1.1.9
cc6kxbarFabricActiveSlot1.3.6.1.4.1.9.9.217.1.2.1
cc6kxbarFabricBackupSlot1.3.6.1.4.1.9.9.217.1.2.2
cc6kxbarSwBusSwitchingStatus1.3.6.1.4.1.9.9.217.1.4.1
cc6kxbarSwBusFailureDuration1.3.6.1.4.1.9.9.217.1.4.2
cc6kxbarSwBusNotifEnable1.3.6.1.4.1.9.9.217.1.4.3
cc6kxbarSwBusUtilization1.3.6.1.4.1.9.9.217.1.4.4
cc6kxbarSwBusPeakUtilization1.3.6.1.4.1.9.9.217.1.4.5
cc6kxbarSwBusPeakTimeUtil1.3.6.1.4.1.9.9.217.1.4.6
cc6kxbarIntBusNotifEnable1.3.6.1.4.1.9.9.217.1.5.1
cc6kxbarFlowCtrlNotifEnable1.3.6.1.4.1.9.9.217.1.6.1
cc6kxbarFlowCtrlBusFIFOThrMode1.3.6.1.4.1.9.9.217.1.6.2
cc6kxbarFlowCtrlBusFIFOThrValue1.3.6.1.4.1.9.9.217.1.6.3
cc6kxbarFlowCtrlBusFIFOTransTime1.3.6.1.4.1.9.9.217.1.6.4
cc6kxbarSysCapPfcOperMode1.3.6.1.4.1.9.9.217.1.7.1
cc6kxbarErrRcvryThreshLink1.3.6.1.4.1.9.9.217.1.8.1
cc6kxbarErrRcvryThreshPersLink1.3.6.1.4.1.9.9.217.1.8.2
cc6kxbarErrRcvrySwitchoverEnable1.3.6.1.4.1.9.9.217.1.8.3
cc6kxbarErrRcvryPersLinkResync1.3.6.1.4.1.9.9.217.1.8.4
cc6kxbarErrRcvryChResyncCount1.3.6.1.4.1.9.9.217.1.8.5
cc6kxbarErrRcvryChResyncInterval1.3.6.1.4.1.9.9.217.1.8.6
cc6kxbarTMSwBusUtilEnable1.3.6.1.4.1.9.9.217.1.9.1.1
cc6kxbarTMSwBusUtilInterval1.3.6.1.4.1.9.9.217.1.9.1.2
cc6kxbarTMSwBusUtilThreshold1.3.6.1.4.1.9.9.217.1.9.1.3
cc6kxbarTMSwBusUtilLogCount1.3.6.1.4.1.9.9.217.1.9.1.4
cc6kxbarTMSwBusUtilLastLogTime1.3.6.1.4.1.9.9.217.1.9.1.5
cc6kxbarTMSwBusUtilLogInterval1.3.6.1.4.1.9.9.217.1.9.1.6
cc6kxbarTMSwBusUtilUtilization1.3.6.1.4.1.9.9.217.1.9.1.7
cc6kxbarTMSwBusUtilNotifEnable1.3.6.1.4.1.9.9.217.1.9.1.8
cc6kxbarTMChUtilLogInterval1.3.6.1.4.1.9.9.217.1.9.2.2
cc6kxbarTMChUtilUtilization1.3.6.1.4.1.9.9.217.1.9.2.3
cc6kxbarTMChUtilNotifEnable1.3.6.1.4.1.9.9.217.1.9.2.4

Tables (8)

NameOID
cc6kxbarLcdBannerTable1.3.6.1.4.1.9.9.217.1.1.5
cc6kxbarModuleModeTable1.3.6.1.4.1.9.9.217.1.2.3
cc6kxbarModuleChannelTable1.3.6.1.4.1.9.9.217.1.2.4
cc6kxbarStatisticsTable1.3.6.1.4.1.9.9.217.1.3.1
cc6kxbarErrorTable1.3.6.1.4.1.9.9.217.1.3.2
cc6kxbarIntBusCRCErrTable1.3.6.1.4.1.9.9.217.1.5.2
cc6kxbarSysCapSwitchResTable1.3.6.1.4.1.9.9.217.1.7.2
cc6kxbarTMChUtilTable1.3.6.1.4.1.9.9.217.1.9.2.1

Traps (8)

NameOID
cc6kxbarSwBusStatusChangeNotif1.3.6.1.4.1.9.9.217.0.1
cc6kxbarIntBusCRCErrExcdNotif1.3.6.1.4.1.9.9.217.0.2
cc6kxbarIntBusCRCErrRcvrdNotif1.3.6.1.4.1.9.9.217.0.3
cc6kxbarFlowCtrlBusThrExcdNotif1.3.6.1.4.1.9.9.217.0.4
cc6kxbarTMSwBusUtilAboveNotif1.3.6.1.4.1.9.9.217.0.5
cc6kxbarTMSwBusUtilBelowNotif1.3.6.1.4.1.9.9.217.0.6
cc6kxbarTMChUtilAboveNotif1.3.6.1.4.1.9.9.217.0.7
cc6kxbarTMChUtilBelowNotif1.3.6.1.4.1.9.9.217.0.8

END OF TOC

Scalar details

cc6kxbarFallbackMode

1.3.6.1.4.1.9.9.217.1.1.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

cc6kxbarFallbackMode controls system fallback to bus-mode after loss of switching fabric module. 'true' - When the last fabric card is removed system will adjust the supervisor and line cards switching mode automatically without resetting the system. With this feature enabled, the switch might lose traffic while it's changing the switching mode. 'false' - All the ports in the system will be disabled when the last fabric card is removed.

cc6kxbarBusOnlyModeAllowed

1.3.6.1.4.1.9.9.217.1.1.2

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates whether bus mode is administratively enabled on the device or not.

cc6kxbarTruncatedModeAllowed

1.3.6.1.4.1.9.9.217.1.1.3

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates whether truncated mode is administratively enabled on the device or not.

cc6kxbarMinFabricPresent

1.3.6.1.4.1.9.9.217.1.1.4

Unsigned32

This object indicates the minimum number of switching fabric capable modules to be present in the system, for any switching fabric capable module to be in 'crossbarmode' indicated by cc6kxbarModuleModeSwitchingMode, when cc6kxbarTruncatedModeOper is 'false'.

cc6kxbarTruncatedModeOper

1.3.6.1.4.1.9.9.217.1.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates if the truncated mode is operationally enabled on the device or not. 'true' - With the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for all the fabric capable modules. 'false'- With the cc6kxbarMinFabricPresent fabric capable modules and the fabric module present in the system, cc6kxbarModuleModeSwitchingMode will be 'crossbarmode' for fabric capable modules.

cc6kxbarDcefOnlyModeAllowed

1.3.6.1.4.1.9.9.217.1.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates whether the dcef mode is enabled on the standby supervisor or not. 'true' - Setting cc6kxbarDcefOnlyModeAllowed to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the active modules to 'dcefmode'. With the active fabric module present in the system, with the switch being in stateful switchover mode, with all the cards that has no distributed Cisco Express forwarding switching support being powered down and on some platforms with standby supervisor ports being shutdown, changing cc6kxbarDcefOnlyModeAllowed to 'true' will make the standby supervisor module reloaded and booted up as distributed forwarding module. 'false'- Setting cc6kxbarDcefOnlyModeAllowed to 'false' makes the cc6kxbarModuleModeSwitchingMode of the standby supervisor module to the default value. Changing cc6kxbarDcefOnlyModeAllowed to 'false' will make the standby supervisor reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode.

cc6kxbarForceBusMode

1.3.6.1.4.1.9.9.217.1.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates whether some affected modules are forced to be in 'busmode' or not. 'true' - Setting cc6kxbarForceBusMode to 'true' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to 'busmode'. Changing the cc6kxbarForceBusMode to 'true' will make all the affected modules reloaded and booted up as non fabric capable modules. 'false'- Setting cc6kxbarForceBusMode to 'false' makes the cc6kxbarModuleModeSwitchingMode of all the affected modules to the default value. Changing cc6kxbarForceBusMode to 'false' will make all the affected modules reloaded and booted up with the default cc6kxbarModuleModeSwitchingMode.

cc6kxbarBusOnlyModeOper

1.3.6.1.4.1.9.9.217.1.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates if the bus mode is operationally enabled on the device or not. 'true' - Modules are allowed to run in 'busmode'. 'false' - None of the modules are allowed to run in 'busmode' i.e., All the non-fabric capable modules will be powered off. Absence of fabric module results in all the fabric capable modules being powered off.

cc6kxbarFabricActiveSlot

1.3.6.1.4.1.9.9.217.1.2.1

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

cc6kxbarFabricActiveSlot indicates the slot number of the active switching fabric module. A value of zero indicates that the active switching fabric module is either powered down or not present in the chassis.

cc6kxbarFabricBackupSlot

1.3.6.1.4.1.9.9.217.1.2.2

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

cc6kxbarFabricBackupSlot indicates the slot number of the backup switching fabric module. A value of zero indicates that the backup switching fabric module is either powered down or not present in the chassis.

cc6kxbarSwBusSwitchingStatus

1.3.6.1.4.1.9.9.217.1.4.1

INTEGER1 = normal2 = stalled3 = isolated · Integer32

Indicates the current switching status of the switching bus on the system. normal -- the switching bus is under normal packet switching operation. stalled -- the switching bus has stopped packet switching but is still attached to the system, i.e., the switching bus is stalled. isolated -- the switching bus has stopped packet switching and is detached from the system, i.e., the switching bus is isolated. The object is only instantiated on systems which support switching bus switching detection feature.

cc6kxbarSwBusFailureDuration

1.3.6.1.4.1.9.9.217.1.4.2

Unsigned32 · seconds

Indicates the failure duration of the switching bus since the switching bus has transitioned out of the normal(1) state as monitored by cc6kxbarSwBusSwitchingStatus. If the object value of cc6kxbarSwBusSwitchingStatus is normal(1), then the object value of cc6kxbarSwBusFailureDuration should be zero. The object is only instantiated on systems which support switching bus switching detection feature.

cc6kxbarSwBusNotifEnable

1.3.6.1.4.1.9.9.217.1.4.3

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates whether or not the notification cc6kxbarSwBusStatusChangeNotif should be generated when there is change in the switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus. The object is only instantiated on systems which support switching bus switching detection feature.

cc6kxbarSwBusUtilization

1.3.6.1.4.1.9.9.217.1.4.4

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Indicates the percentage of bandwidth utilization of the switching bus.

cc6kxbarSwBusPeakUtilization

1.3.6.1.4.1.9.9.217.1.4.5

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Indicates the peak percentage value of bandwidth utilization of the switching bus since the system started.

cc6kxbarSwBusPeakTimeUtil

1.3.6.1.4.1.9.9.217.1.4.6

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Indicates the time at which the peak percentage value of bandwidth utilization of the switching bus value occurred.

cc6kxbarIntBusNotifEnable

1.3.6.1.4.1.9.9.217.1.5.1

BITS

Indicates whether the generation of a specified notification for internal bus is enabled or not. If a bit corresponding to a notification is set to 1, then that notification can be generated. intBusCRCErrExcd -- the cc6kxbarIntBusCRCErrExcdNotif notification. intBusCRCErrRcvrd -- the cc6kxbarIntBusCRCErrRcvrdNotif notification.

cc6kxbarFlowCtrlNotifEnable

1.3.6.1.4.1.9.9.217.1.6.1

BITS

Specifies whether the generation of a specified notification for flow control feature is enabled or not. If a bit corresponding to a notification is set to one, then that notification can be generated. busThreshExcd -- the cc6kxbarFlowCtrlBusThrExcdNotif notification.

cc6kxbarFlowCtrlBusFIFOThrMode

1.3.6.1.4.1.9.9.217.1.6.2

INTEGER1 = off2 = on3 = auto · Integer32

Specifies the mode configuration of the system bus flow control FIFO threshold. off -- the flow control FIFO threshold is set to the original value defined by the system. on -- the flow control FIFO threshold is set to the lower value defined by the system. auto -- the system starts monitoring the system bus flow control FIFO threshold and will change the flow control FIFO threshold from the original value to the lower value when the system detects the first occurrence of the threshold exceeding on a physical entity (such as a module) over the system allowed limit.

cc6kxbarFlowCtrlBusFIFOThrValue

1.3.6.1.4.1.9.9.217.1.6.3

INTEGER1 = original2 = lower · Integer32

Indicates the current value of the system bus flow control FIFO threshold, whether it is the original value or the lower value.

cc6kxbarFlowCtrlBusFIFOTransTime

1.3.6.1.4.1.9.9.217.1.6.4

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

Indicates the value of sysUpTime at the time that the system bus flow control FIFO threshold is transitioned to lower value when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'lower'. This object will take on the value of zero when the object value of cc6kxbarFlowCtrlBusFIFOThrValue is 'original'.

cc6kxbarSysCapPfcOperMode

1.3.6.1.4.1.9.9.217.1.7.1

INTEGER1 = unknown2 = pfc3a3 = pfc3b4 = pfc3bxl5 = pfc3cst16 = pfc3cxlst17 = pfc3c8 = pfc3cxl9 = pfc410 = pfc4xl11 = pfc4xxl12 = pfc4lite · Integer32

Indicates the operating mode of the policy feature card (PFC). unknown -- unknown. pfc3a -- Policy feature card 3A. pfc3b -- Policy feature card 3B. pfc3bxl -- Policy feature card 3B XL. pfc3cst1 -- Policy feature card 3C ST1. pfc3cxlst1 -- Policy feature card 3C XL ST1. pfc3c -- Policy feature card 3C. pfc3cxl -- Policy feature card 3C XL. pfc4 -- Policy feature card 4. pfc4xl -- Policy feature card 4 XL. pfc4xxl -- Policy feature card 4 XXL. pfc4lite -- Policy feature card 4 Lite.

1.3.6.1.4.1.9.9.217.1.8.1

Unsigned32 (1..4294967295)

Specifies the threshold on fabric link errors occurring in a channel for the fabric error recovery feature.

1.3.6.1.4.1.9.9.217.1.8.2

Unsigned32 (1..4294967295)

Specifies the threshold on persistent fabric link errors occurring in a channel for the fabric error recovery feature.

cc6kxbarErrRcvrySwitchoverEnable

1.3.6.1.4.1.9.9.217.1.8.3

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Specifies whether the switchover to the standby fabric module is enabled or not on the detection of excessive fabric link errors occurring in a channel for the fabric error recovery feature.

cc6kxbarErrRcvryPersLinkResync

1.3.6.1.4.1.9.9.217.1.8.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Specifies whether the system will resync the channel or not on the detection of excessive persistent fabric link errors in a channel for the fabric error recovery feature.

cc6kxbarErrRcvryChResyncCount

1.3.6.1.4.1.9.9.217.1.8.5

Unsigned32 (1..4294967295)

Specifies the consecutive number of times of channel resync within the time interval as specified by cc6kxbarErrRcvryChResyncInterval, over which the channel resync is considered as failure for the fabric error recovery feature.

cc6kxbarErrRcvryChResyncInterval

1.3.6.1.4.1.9.9.217.1.8.6

Unsigned32 (1..4294967295) · milliseconds

Specifies the time interval for the consecutive counting of channel resync for the fabric error recovery feature.

cc6kxbarTMSwBusUtilEnable

1.3.6.1.4.1.9.9.217.1.9.1.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Specifies whether the traffic monitor feature is enabled on the switching bus or not.

cc6kxbarTMSwBusUtilInterval

1.3.6.1.4.1.9.9.217.1.9.1.2

Unsigned32 (1..4294967295) · seconds

Specifies the interval at the end of which the switching bus traffic utilization is compared against cc6kxbarTMSwBusUtilThreshold.

cc6kxbarTMSwBusUtilThreshold

1.3.6.1.4.1.9.9.217.1.9.1.3

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Specifies the threshold of the switching bus traffic utilization.

cc6kxbarTMSwBusUtilLogCount

1.3.6.1.4.1.9.9.217.1.9.1.4

Counter32

Indicates the number of times the following events are logged for the switching bus: 1. the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). 2. the switching bus traffic utilization has fallen below the configured threshold.

cc6kxbarTMSwBusUtilLastLogTime

1.3.6.1.4.1.9.9.217.1.9.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Indicates the last logging time of the events as counted in cc6kxbarTMSwBusUtilLogCount. This object will contain 0-1-1,00:00:00.0 when the value of cc6kxbarTMSwBusUtilLogCount is zero.

cc6kxbarTMSwBusUtilLogInterval

1.3.6.1.4.1.9.9.217.1.9.1.6

Unsigned32 (1..4294967295) · seconds

Specifies the logging interval if the switching bus traffic utilization keeps staying above the cc6kxbarTMSwBusUtilThreshold.

cc6kxbarTMSwBusUtilUtilization

1.3.6.1.4.1.9.9.217.1.9.1.7

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

The switching bus traffic utilization included in the notification currently being sent.

cc6kxbarTMSwBusUtilNotifEnable

1.3.6.1.4.1.9.9.217.1.9.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Specifies whether the generation of c6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMSwBusUtilAboveNotif and c6kxbarTMSwBusUtilBelowNotif notifications is disabled.

cc6kxbarTMChUtilLogInterval

1.3.6.1.4.1.9.9.217.1.9.2.2

Unsigned32 (1..4294967295) · seconds

Specifies the logging interval if the traffic utilization for a fabric channel on a given traffic direction keeps staying above its corresponding cc6kxbarTMChUtilThreshold.

cc6kxbarTMChUtilUtilization

1.3.6.1.4.1.9.9.217.1.9.2.3

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

The traffic utilization on a fabric channel for a given traffic direction included in the notification currently being sent.

cc6kxbarTMChUtilNotifEnable

1.3.6.1.4.1.9.9.217.1.9.2.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Specifies whether the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled or not. When this object is 'true', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is enabled. When this object is 'false', the generation of cc6kxbarTMChUtilAboveNotif and cc6kxbarTMChUtilBelowNotif notifications is disabled.

Table details

cc6kxbarLcdBannerTable

1.3.6.1.4.1.9.9.217.1.1.5

Index: cc6kxbarLcdBannerIndex

cc6kxbarLcdBannerTable configures the Lcd banner of the fabric module.

cc6kxbarLcdBannerIndex

1.3.6.1.4.1.9.9.217.1.1.5.1.1

Unsigned32

Object which specifies a unique entry in the table.

cc6kxbarLcdBannerBanner

1.3.6.1.4.1.9.9.217.1.1.5.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

Message that would be displayed on the fabric card LCD. The size of cc6kxbarLcdBannerBanner should be less than or equal to the cc6kxbarLcdBannerMaxSize value.

cc6kxbarLcdBannerMaxSize

1.3.6.1.4.1.9.9.217.1.1.5.1.3

Unsigned32

Maximum size of the associated cc6kxbarLcdBannerBanner object.

cc6kxbarModuleModeTable

1.3.6.1.4.1.9.9.217.1.2.3

Index: cc6kxbarModuleModeModule

cc6kxbarModuleModeTable indicates the switching mode of each module in the system.

cc6kxbarModuleModeModule

1.3.6.1.4.1.9.9.217.1.2.3.1.1

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

The module slot number.

cc6kxbarModuleModeSwitchingMode

1.3.6.1.4.1.9.9.217.1.2.3.1.2

INTEGER1 = busmode2 = crossbarmode3 = dcefmode · Integer32

cc6kxbarModuleModeSwitchingMode indicates switching mode of the cc6kxbarModuleModeModule. 'busmode' - Modules in this mode don't use fabric. Backplane is used for both lookup and data forwarding. 'crossbarmode' - Modules in this mode use backplane for forwarding decision and fabric for data forwarding 'dcefmode' - Modules in this mode use fabric for data forwarding and local forwarding is enabled.

cc6kxbarModuleChannelTable

1.3.6.1.4.1.9.9.217.1.2.4

Index: cc6kxbarModuleChannelModule · cc6kxbarModuleChannelChannel

cc6kxbarModuleChannelTable shows the operational status of fabric channels. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero.

cc6kxbarModuleChannelModule

1.3.6.1.4.1.9.9.217.1.2.4.1.1

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

The module slot number.

cc6kxbarModuleChannelChannel

1.3.6.1.4.1.9.9.217.1.2.4.1.2

FabricChannelNumberFabric channel number. · Unsigned32 · hint d

Fabric channel number of the cc6kxbarModuleChannelModule.

cc6kxbarModuleChannelModStatus

1.3.6.1.4.1.9.9.217.1.2.4.1.3

ChannelStatus1 = ok2 = syncError3 = heartbeatError4 = crcError5 = bufferError6 = timeoutError7 = unusedStatus of the Channel. · Integer32

The status of the fabric channel at the cc6kxbarModuleChannelModule.

cc6kxbarModuleChannelFabStatus

1.3.6.1.4.1.9.9.217.1.2.4.1.4

ChannelStatus1 = ok2 = syncError3 = heartbeatError4 = crcError5 = bufferError6 = timeoutError7 = unusedStatus of the Channel. · Integer32

The status of the fabric channel at the cc6kxbarFabricActiveSlot.

cc6kxbarModuleChannelSpeed

1.3.6.1.4.1.9.9.217.1.2.4.1.5

Gauge32

The speed in mega bits per second of the cc6kxbarModuleChannelChannel for cc6kxbarModuleChannelModule.

cc6kxbarStatisticsTable

1.3.6.1.4.1.9.9.217.1.3.1

Index: cc6kxbarStatisticsModule · cc6kxbarStatisticsChannel

cc6kxbarStatisticsTable gives the fabric channel counters and utilization information. This table will be instantiated when cc6kxbarFabricActiveSlot has a valid value other than zero.

cc6kxbarStatisticsModule

1.3.6.1.4.1.9.9.217.1.3.1.1.1

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

The module slot number.

cc6kxbarStatisticsChannel

1.3.6.1.4.1.9.9.217.1.3.1.1.2

FabricChannelNumberFabric channel number. · Unsigned32 · hint d

Fabric channel number associated with the cc6kxbarStatisticsModule.

cc6kxbarStatisticsInErrors

1.3.6.1.4.1.9.9.217.1.3.1.1.3

Counter32

The total number of error packets received on cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized.

cc6kxbarStatisticsOutErrors

1.3.6.1.4.1.9.9.217.1.3.1.1.4

Counter32

The total number of error packets transmitted on cc6kxbarStatisticsModule through the cc6kxbarStatisticsChannel since this entry was last initialized.

cc6kxbarStatisticsOutDropped

1.3.6.1.4.1.9.9.217.1.3.1.1.5

Counter32

The total number of dropped packets transmitted on the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule since this entry was last initialized.

cc6kxbarStatisticsInUtil

1.3.6.1.4.1.9.9.217.1.3.1.1.6

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Input utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.

cc6kxbarStatisticsOutUtil

1.3.6.1.4.1.9.9.217.1.3.1.1.7

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Output utilization of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.

cc6kxbarStatisticsPeakInUtil

1.3.6.1.4.1.9.9.217.1.3.1.1.8

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Indicates the peak value of cc6kxbarStatisticsInUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.

cc6kxbarStatisticsPeakTmInUtil

1.3.6.1.4.1.9.9.217.1.3.1.1.9

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakInUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakInUtil is '0'.

cc6kxbarStatisticsPeakOutUtil

1.3.6.1.4.1.9.9.217.1.3.1.1.10

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Indicates the peak value of cc6kxbarStatisticsOutUtil of the cc6kxbarStatisticsChannel for cc6kxbarStatisticsModule.

cc6kxbarStatisticsPeakTmOutUtil

1.3.6.1.4.1.9.9.217.1.3.1.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Indicates the time of most recent change in the corresponding instance value of cc6kxbarStatisticsPeakOutUtil. This object contains value 0x0000010100000000 when the corresponding instance value of cc6kxbarStatisticsPeakOutUtil is '0'.

cc6kxbarStatisticsLbusDrops

1.3.6.1.4.1.9.9.217.1.3.1.1.12

Counter32

This object indicates the number of packets that have been deterministically dropped due to the threshold on the local bus FIFO, errors and exception conditions.

cc6kxbarErrorTable

1.3.6.1.4.1.9.9.217.1.3.2

Index: cc6kxbarErrorModule · cc6kxbarErrorChannel

cc6kxbarErrorTable provides the fabric channel error information. This table will be instantiated only when cc6kxbarFabricActiveSlot has a valid value other than zero.

cc6kxbarErrorModule

1.3.6.1.4.1.9.9.217.1.3.2.1.1

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

The module slot number.

cc6kxbarErrorChannel

1.3.6.1.4.1.9.9.217.1.3.2.1.2

FabricChannelNumberFabric channel number. · Unsigned32 · hint d

Fabric channel number associated with the cc6kxbarErrorModule.

cc6kxbarErrorModuleCrc

1.3.6.1.4.1.9.9.217.1.3.2.1.3

Gauge32

Indicates the total number of CRC error packets for the cc6kxbarErrorChannel of the cc6kxbarErrorModule.

cc6kxbarErrorModuleHbeat

1.3.6.1.4.1.9.9.217.1.3.2.1.4

Gauge32

Indicates the total number of heartbeat misses detected for the cc6kxbarErrorChannel of the cc6kxbarErrorModule.

cc6kxbarErrorModuleSync

1.3.6.1.4.1.9.9.217.1.3.2.1.5

Gauge32

Indicates the total number of times cc6kxbarErrorModule could not sync to the active switching fabric module.

cc6kxbarErrorModuleDDRSync

1.3.6.1.4.1.9.9.217.1.3.2.1.6

Gauge32

Indicates the total number of DDR(Double Data Rate) channel sync errors for the cc6kxbarErrorChannel of the cc6kxbarErrorModule.

cc6kxbarErrorChannelSync

1.3.6.1.4.1.9.9.217.1.3.2.1.7

Gauge32

Indicates the total number of sync errors received at cc6kxbarErrorChannel.

cc6kxbarErrorChannelBuffer

1.3.6.1.4.1.9.9.217.1.3.2.1.8

Gauge32

Indicates the total number of times the memory buffer for cc6kxbarErrorChannel of the cc6kxbarErrorModule is full.

cc6kxbarErrorChannelTimeout

1.3.6.1.4.1.9.9.217.1.3.2.1.9

Gauge32

Indicates the total number of timeouts for input from the cc6kxbarErrorChannel of the cc6kxbarErrorModule.

cc6kxbarIntBusCRCErrTable

1.3.6.1.4.1.9.9.217.1.5.2

Index: entPhysicalIndex

A table containing internal bus CRC error information on a list of physical entities (such as modules).

from ENTITY-MIB

entPhysicalIndex

PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d

The index for this entry.

cc6kxbarIntBusCRCErrExcdStatus

1.3.6.1.4.1.9.9.217.1.5.2.1.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Indicates whether the internal bus CRC error on a physical entity is currently exceeding the fatal threshold or not.

cc6kxbarIntBusCRCErrExcdCount

1.3.6.1.4.1.9.9.217.1.5.2.1.2

Unsigned32

Indicates the number of times the internal bus CRC error on a physical entity has exceeded the fatal threshold.

cc6kxbarSysCapSwitchResTable

1.3.6.1.4.1.9.9.217.1.7.2

Index: entPhysicalIndex

A cc6kxbarSysCapSwitchResTable entry lists the capacity information of the switching resources for ENTITY-MIB entPhysicalTable entries of manageable components with type entPhysicalClass module(9).

from ENTITY-MIB

entPhysicalIndex

PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d

The index for this entry.

cc6kxbarSysCapSwitchResSeries

1.3.6.1.4.1.9.9.217.1.7.2.1.1

INTEGER1 = unknown2 = supervisor3 = classic4 = fabric5 = dcef7206 = cef7207 = dcef2568 = cef256 · Integer32

Indicates the module series for traffic forwarding options. unknown -- unknown. supervisor -- supervisor module. classic -- classic module. fabric -- fabric module. dcef720 -- dCEF720 module. cef720 -- CEF720 module. dcef256 -- dCEF256 module. cef256 -- CEF256 module.

cc6kxbarSysCapSwitchResCefMode

1.3.6.1.4.1.9.9.217.1.7.2.1.2

INTEGER1 = notApplicable2 = dcef3 = cef · Integer32

Indicates the Cisco Express Forwarding (CEF) mode of the module. notApplicable -- not applicable for this module. dcef -- distributed CEF. cef -- CEF.

cc6kxbarTMChUtilTable

1.3.6.1.4.1.9.9.217.1.9.2.1

Index: cc6kxbarTMChUtilModule · cc6kxbarTMChUtilChannel · cc6kxbarTMChUtilDirection

cc6kxbarTrafficMntrChUtilTable provides the information on the traffic utilization of each fabric channel associated with each module slot for a given traffic direction in the chassis.

cc6kxbarTMChUtilModule

1.3.6.1.4.1.9.9.217.1.9.2.1.1.1

ModuleSlotNumberSlot number of the module. · Unsigned32 · hint d

Indicates the module slot number in the chassis.

cc6kxbarTMChUtilChannel

1.3.6.1.4.1.9.9.217.1.9.2.1.1.2

FabricChannelNumberFabric channel number. · Unsigned32 · hint d

Indicates the fabric channel number associated with the corresponding cc6kxbarTMChUtilModule.

cc6kxbarTMChUtilDirection

1.3.6.1.4.1.9.9.217.1.9.2.1.1.3

INTEGER1 = ingress2 = egress · Integer32

Indicates the direction of traffic to be monitored.

cc6kxbarTMChUtilEnable

1.3.6.1.4.1.9.9.217.1.9.2.1.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Specifies whether the traffic monitor feature is enabled on a fabric channel for a given traffic direction or not.

cc6kxbarTMChUtilInterval

1.3.6.1.4.1.9.9.217.1.9.2.1.1.5

Unsigned32 (1..4294967295) · seconds

Specifies the interval at the end of which the traffic utilization on a fabric channel for a given traffic direction is compared against its corresponding cc6kxbarTMChUtilThreshold.

cc6kxbarTMChUtilThreshold

1.3.6.1.4.1.9.9.217.1.9.2.1.1.6

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Specifies the threshold of the traffic utilization on a fabric channel for a given traffic direction.

cc6kxbarTMChUtilLogCount

1.3.6.1.4.1.9.9.217.1.9.2.1.1.7

Counter32

Indicates the number of times the following events are logged on a fabric channel for a given direction. 1. the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). 2. the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold.

cc6kxbarTMChUtilLastLogTime

1.3.6.1.4.1.9.9.217.1.9.2.1.1.8

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Indicates the last logging time of the events as counted in the corresponding cc6kxbarTMChUtilLogCount on a fabric channel for a given traffic direction. This object will contain 0-1-1,00:00:00.0 when the corresponding cc6kxbarTMChUtilLogCount is zero.

Trap details

cc6kxbarSwBusStatusChangeNotif

1.3.6.1.4.1.9.9.217.0.1

A cc6kxbarSwBusStatusChangeNotif notification is sent by the device when there is change in switching status of the switching bus as monitored by cc6kxbarSwBusSwitchingStatus.

cc6kxbarSwBusSwitchingStatus

1.3.6.1.4.1.9.9.217.1.4.1

INTEGER1 = normal2 = stalled3 = isolated · Integer32

Indicates the current switching status of the switching bus on the system. normal -- the switching bus is under normal packet switching operation. stalled -- the switching bus has stopped packet switching but is still attached to the system, i.e., the switching bus is stalled. isolated -- the switching bus has stopped packet switching and is detached from the system, i.e., the switching bus is isolated. The object is only instantiated on systems which support switching bus switching detection feature.

cc6kxbarSwBusFailureDuration

1.3.6.1.4.1.9.9.217.1.4.2

Unsigned32 · seconds

Indicates the failure duration of the switching bus since the switching bus has transitioned out of the normal(1) state as monitored by cc6kxbarSwBusSwitchingStatus. If the object value of cc6kxbarSwBusSwitchingStatus is normal(1), then the object value of cc6kxbarSwBusFailureDuration should be zero. The object is only instantiated on systems which support switching bus switching detection feature.

cc6kxbarIntBusCRCErrExcdNotif

1.3.6.1.4.1.9.9.217.0.2

A cc6kxbarIntBusCRCThreshExcdNotif notification is sent by the system when the system has detected that the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has exceeded the fatal threshold.

entPhysicalName

1.3.6.1.2.1.47.1.1.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's 'console'. This might be a text name (e.g., 'console') or a simple component number (e.g., port or module number, such as '1'), depending on the physical component naming syntax of the device. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1.

entPhysicalVendorType

1.3.6.1.2.1.47.1.1.1.1.3

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

An indication of the vendor-specific hardware type of the physical entity. Note that this is different from the definition of MIB-II's sysObjectID. An agent should set this object to an enterprise-specific registration identifier value indicating the specific equipment type in detail. The associated instance of entPhysicalClass is used to indicate the general type of hardware device. If no vendor-specific registration identifier exists for this physical entity, or the value is unknown by this agent, then the value { 0 0 } is returned.

cc6kxbarIntBusCRCErrRcvrdNotif

1.3.6.1.4.1.9.9.217.0.3

A cc6kxbarIntBusCRCErrRcvrdNotif notification is sent by the system when the system has recovered as the internal bus CRC error on a physical entity (such as a module) as specified by entPhysicalName has fallen below the normal threshold.

entPhysicalName

1.3.6.1.2.1.47.1.1.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's 'console'. This might be a text name (e.g., 'console') or a simple component number (e.g., port or module number, such as '1'), depending on the physical component naming syntax of the device. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1.

entPhysicalVendorType

1.3.6.1.2.1.47.1.1.1.1.3

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

An indication of the vendor-specific hardware type of the physical entity. Note that this is different from the definition of MIB-II's sysObjectID. An agent should set this object to an enterprise-specific registration identifier value indicating the specific equipment type in detail. The associated instance of entPhysicalClass is used to indicate the general type of hardware device. If no vendor-specific registration identifier exists for this physical entity, or the value is unknown by this agent, then the value { 0 0 } is returned.

cc6kxbarFlowCtrlBusThrExcdNotif

1.3.6.1.4.1.9.9.217.0.4

A cc6kxbarFlowCtrlBusThrExcdNotif notification is sent by the system when the system detects the first occurrence of the system bus flow control FIFO threshold exceeding on a physical entity (such as a module) over the system allowed limit when the object value of cc6kxbarFlowCtrlBusFIFOThrMode is 'auto'.

entPhysicalName

1.3.6.1.2.1.47.1.1.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's 'console'. This might be a text name (e.g., 'console') or a simple component number (e.g., port or module number, such as '1'), depending on the physical component naming syntax of the device. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1.

entPhysicalVendorType

1.3.6.1.2.1.47.1.1.1.1.3

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

An indication of the vendor-specific hardware type of the physical entity. Note that this is different from the definition of MIB-II's sysObjectID. An agent should set this object to an enterprise-specific registration identifier value indicating the specific equipment type in detail. The associated instance of entPhysicalClass is used to indicate the general type of hardware device. If no vendor-specific registration identifier exists for this physical entity, or the value is unknown by this agent, then the value { 0 0 } is returned.

cc6kxbarTMSwBusUtilAboveNotif

1.3.6.1.4.1.9.9.217.0.5

This notification is sent when the switching bus traffic utilization has risen above the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMSwBusUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilAboveNotif is sent.

cc6kxbarTMSwBusUtilUtilization

1.3.6.1.4.1.9.9.217.1.9.1.7

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

The switching bus traffic utilization included in the notification currently being sent.

cc6kxbarTMSwBusUtilThreshold

1.3.6.1.4.1.9.9.217.1.9.1.3

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Specifies the threshold of the switching bus traffic utilization.

cc6kxbarTMSwBusUtilInterval

1.3.6.1.4.1.9.9.217.1.9.1.2

Unsigned32 (1..4294967295) · seconds

Specifies the interval at the end of which the switching bus traffic utilization is compared against cc6kxbarTMSwBusUtilThreshold.

entPhysicalDescr

1.3.6.1.2.1.47.1.1.1.1.2

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

A textual description of physical entity. This object should contain a string that identifies the manufacturer's name for the physical entity and should be set to a distinct value for each version or model of the physical entity.

cc6kxbarTMSwBusUtilBelowNotif

1.3.6.1.4.1.9.9.217.0.6

This notification is sent when the switching bus traffic utilization has fallen below the configured threshold (as specified by cc6kxbarTMSwBusUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMSwBusUtilBelowNotif is sent.

cc6kxbarTMSwBusUtilUtilization

1.3.6.1.4.1.9.9.217.1.9.1.7

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

The switching bus traffic utilization included in the notification currently being sent.

cc6kxbarTMSwBusUtilThreshold

1.3.6.1.4.1.9.9.217.1.9.1.3

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Specifies the threshold of the switching bus traffic utilization.

cc6kxbarTMSwBusUtilInterval

1.3.6.1.4.1.9.9.217.1.9.1.2

Unsigned32 (1..4294967295) · seconds

Specifies the interval at the end of which the switching bus traffic utilization is compared against cc6kxbarTMSwBusUtilThreshold.

entPhysicalDescr

1.3.6.1.2.1.47.1.1.1.1.2

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

A textual description of physical entity. This object should contain a string that identifies the manufacturer's name for the physical entity and should be set to a distinct value for each version or model of the physical entity.

cc6kxbarTMChUtilAboveNotif

1.3.6.1.4.1.9.9.217.0.7

This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has risen above its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold), or has kept staying above the configured threshold at a logging interval (as specified by cc6kxbarTMChUtilLogInterval). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilAboveNotif is sent.

cc6kxbarTMChUtilUtilization

1.3.6.1.4.1.9.9.217.1.9.2.3

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

The traffic utilization on a fabric channel for a given traffic direction included in the notification currently being sent.

cc6kxbarTMChUtilThreshold

1.3.6.1.4.1.9.9.217.1.9.2.1.1.6

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Specifies the threshold of the traffic utilization on a fabric channel for a given traffic direction.

cc6kxbarTMChUtilInterval

1.3.6.1.4.1.9.9.217.1.9.2.1.1.5

Unsigned32 (1..4294967295) · seconds

Specifies the interval at the end of which the traffic utilization on a fabric channel for a given traffic direction is compared against its corresponding cc6kxbarTMChUtilThreshold.

entPhysicalDescr

1.3.6.1.2.1.47.1.1.1.1.2

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

A textual description of physical entity. This object should contain a string that identifies the manufacturer's name for the physical entity and should be set to a distinct value for each version or model of the physical entity.

cc6kxbarTMChUtilBelowNotif

1.3.6.1.4.1.9.9.217.0.8

This notification is sent when the traffic utilization on a fabric channel for a given traffic direction has fallen below its corresponding configured threshold (as specified by cc6kxbarTMChUtilThreshold). The varbind entPhysicalDescr specifies the physical entity (such as chassis) for which the cc6kxbarTMChUtilBelowNotif is sent.

cc6kxbarTMChUtilUtilization

1.3.6.1.4.1.9.9.217.1.9.2.3

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

The traffic utilization on a fabric channel for a given traffic direction included in the notification currently being sent.

cc6kxbarTMChUtilThreshold

1.3.6.1.4.1.9.9.217.1.9.2.1.1.6

PercentAn integer that is in the range of a percent value. (0..100) · Integer32

Specifies the threshold of the traffic utilization on a fabric channel for a given traffic direction.

cc6kxbarTMChUtilInterval

1.3.6.1.4.1.9.9.217.1.9.2.1.1.5

Unsigned32 (1..4294967295) · seconds

Specifies the interval at the end of which the traffic utilization on a fabric channel for a given traffic direction is compared against its corresponding cc6kxbarTMChUtilThreshold.

entPhysicalDescr

1.3.6.1.2.1.47.1.1.1.1.2

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

A textual description of physical entity. This object should contain a string that identifies the manufacturer's name for the physical entity and should be set to a distinct value for each version or model of the physical entity.

↑ To TOC