This MIB module provides information about the status of display devices such as Light Emitting Diodes (LEDs) and alphanumeric displays present on the physical entities contained by the managed system.
PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d
The index for this entry.
ceDisplayIndex
1.3.6.1.4.1.9.9.344.1.1.1.1
Unsigned32 (1..1024)
An arbitrary index that uniquely identifies an LED or an alphanumeric display on the physical entity identified by entPhysicalIndex.
ceDisplayType
1.3.6.1.4.1.9.9.344.1.1.1.2
CDisplayType1 = led2 = alphanumericAn integer value that indicates the type of display device. · Integer32
This object indicates the type of display described in this entry. i.e. whether it is an LED display or an alphanumeric display.
ceDisplayName
1.3.6.1.4.1.9.9.344.1.1.1.3
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t
This object provides a human-readable string which is the name for the display device specified in this entry.
ceDisplayState
1.3.6.1.4.1.9.9.344.1.1.1.4
CDisplayState1 = unknown2 = off3 = on4 = blinkingAn integer value that describes the state of the display. · Integer32
This object indicates the current display state for the display specified in this entry.
ceDisplayColor
1.3.6.1.4.1.9.9.344.1.1.1.5
CDisplayColor1 = unknown2 = white3 = red4 = green5 = yellow6 = amber7 = blue8 = greenAndAmberAn integer value that describes the color of the display.
'greenAndAmber' - Indicates that the display color
toggles between green and amber. · Integer32
This object indicates the color currently seen on the display specified in this entry. If the display specified by this entry is an alphanumeric display, i.e. ceDisplayType is of type 'alphanumeric' then, color may not apply and the agent may choose to indicate this by setting this object to 'unknown'.
ceDisplayText
1.3.6.1.4.1.9.9.344.1.1.1.6
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t
This object provides a human-readable string which is the text currently displayed in the alphanumeric display specified in this entry. If the display specified by this entry is an LED, i.e. ceDisplayType is of type 'led' then, this object would be an empty string.
ceDisplayBeaconTable
1.3.6.1.4.1.9.9.344.1.2
Index: entPhysicalIndex · ceDisplayIndex
This table provides functionality to manage beacon display devices in the managed system.
PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d
The index for this entry.
ceDisplayBeaconEnabled
1.3.6.1.4.1.9.9.344.1.2.1.1
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
This object specifies if the beacon functionality is administratively enabled for this display device.
'true' - beacon functionality is administratively
enabled
'false' - beacon functionality is administratively
disabled.