EZ5 MIB Catalog

CISCO-ENVMON-MIB

2018-03-21

Added an object ciscoEnvMonTemperatureStatusValueRev1 to CiscoEnvMonTemperatureStatusEntry for support of negative temperature

Download CISCO-ENVMON-MIB.txt Open CISCO-ENVMON-MIB.txt in a new tab

SCALARS (8) · TABLES (4) · TRAPS (9)

Scalars (8)

NameOID
ciscoEnvMonPresent1.3.6.1.4.1.9.9.13.1.1
ciscoEnvMonAlarmContacts1.3.6.1.4.1.9.9.13.1.6
ciscoEnvMonEnableShutdownNotification1.3.6.1.4.1.9.9.13.2.1
ciscoEnvMonEnableVoltageNotification1.3.6.1.4.1.9.9.13.2.2
ciscoEnvMonEnableTemperatureNotification1.3.6.1.4.1.9.9.13.2.3
ciscoEnvMonEnableFanNotification1.3.6.1.4.1.9.9.13.2.4
ciscoEnvMonEnableRedundantSupplyNotification1.3.6.1.4.1.9.9.13.2.5
ciscoEnvMonEnableStatChangeNotif1.3.6.1.4.1.9.9.13.2.6

Tables (4)

NameOID
ciscoEnvMonVoltageStatusTable1.3.6.1.4.1.9.9.13.1.2
ciscoEnvMonTemperatureStatusTable1.3.6.1.4.1.9.9.13.1.3
ciscoEnvMonFanStatusTable1.3.6.1.4.1.9.9.13.1.4
ciscoEnvMonSupplyStatusTable1.3.6.1.4.1.9.9.13.1.5

Traps (9)

NameOID
ciscoEnvMonShutdownNotification1.3.6.1.4.1.9.9.13.3.0.1
ciscoEnvMonVoltageNotification(deprecated)1.3.6.1.4.1.9.9.13.3.0.2
ciscoEnvMonTemperatureNotification(deprecated)1.3.6.1.4.1.9.9.13.3.0.3
ciscoEnvMonFanNotification(deprecated)1.3.6.1.4.1.9.9.13.3.0.4
ciscoEnvMonRedundantSupplyNotification(deprecated)1.3.6.1.4.1.9.9.13.3.0.5
ciscoEnvMonVoltStatusChangeNotif1.3.6.1.4.1.9.9.13.3.0.6
ciscoEnvMonTempStatusChangeNotif1.3.6.1.4.1.9.9.13.3.0.7
ciscoEnvMonFanStatusChangeNotif1.3.6.1.4.1.9.9.13.3.0.8
ciscoEnvMonSuppStatusChangeNotif1.3.6.1.4.1.9.9.13.3.0.9

END OF TOC

Scalar details

ciscoEnvMonPresent

1.3.6.1.4.1.9.9.13.1.1

INTEGER1 = oldAgs2 = ags3 = c70004 = ci6 = cAccessMon7 = cat60008 = ubr72009 = cat400010 = c1000011 = osr760012 = c760013 = c37xx14 = other15 = c730116 = c7304 · Integer32

The type of environmental monitor located in the chassis. An oldAgs environmental monitor card is identical to an ags environmental card except that it is not capable of supplying data, and hence no instance of the remaining objects in this MIB will be returned in response to an SNMP query. Note that only a firmware upgrade is required to convert an oldAgs into an ags card.

ciscoEnvMonAlarmContacts

1.3.6.1.4.1.9.9.13.1.6

BITS

Each bit is set to reflect the respective alarm being set. The bit will be cleared when the respective alarm is cleared.

ciscoEnvMonEnableShutdownNotification

1.3.6.1.4.1.9.9.13.2.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This variable indicates whether the system produces the ciscoEnvMonShutdownNotification. A false value will prevent shutdown notifications from being generated by this system.

ciscoEnvMonEnableVoltageNotification

1.3.6.1.4.1.9.9.13.2.2

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This variable indicates whether the system produces the ciscoEnvMonVoltageNotification. A false value will prevent voltage notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.

ciscoEnvMonEnableTemperatureNotification

1.3.6.1.4.1.9.9.13.2.3

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This variable indicates whether the system produces the ciscoEnvMonTemperatureNotification. A false value prevents temperature notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.

ciscoEnvMonEnableFanNotification

1.3.6.1.4.1.9.9.13.2.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This variable indicates whether the system produces the ciscoEnvMonFanNotification. A false value prevents fan notifications from being sent by this entity. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.

ciscoEnvMonEnableRedundantSupplyNotification

1.3.6.1.4.1.9.9.13.2.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This variable indicates whether the system produces the ciscoEnvMonRedundantSupplyNotification. A false value prevents redundant supply notifications from being generated by this system. This object is deprecated in favour of ciscoEnvMonEnableStatChangeNotif.

ciscoEnvMonEnableStatChangeNotif

1.3.6.1.4.1.9.9.13.2.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This variable indicates whether the system produces the ciscoEnvMonVoltStatusChangeNotif, ciscoEnvMonTempStatusChangeNotif, ciscoEnvMonFanStatusChangeNotif and ciscoEnvMonSuppStatusChangeNotif. A false value will prevent these notifications from being generated by this system.

Table details

ciscoEnvMonVoltageStatusTable

1.3.6.1.4.1.9.9.13.1.2

Index: ciscoEnvMonVoltageStatusIndex

The table of voltage status maintained by the environmental monitor.

ciscoEnvMonVoltageStatusIndex

1.3.6.1.4.1.9.9.13.1.2.1.1

Integer32 (0..2147483647)

Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.

ciscoEnvMonVoltageStatusDescr

1.3.6.1.4.1.9.9.13.1.2.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonVoltageStatusValue

1.3.6.1.4.1.9.9.13.1.2.1.3

CiscoSignedGaugeRepresents the current value of an entity, as a signed integer. · Integer32 · millivolts

The current measurement of the testpoint being instrumented.

ciscoEnvMonVoltageThresholdLow

1.3.6.1.4.1.9.9.13.1.2.1.4

Integer32 · millivolts

The lowest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated.

ciscoEnvMonVoltageThresholdHigh

1.3.6.1.4.1.9.9.13.1.2.1.5

Integer32 · millivolts

The highest value that the associated instance of the object ciscoEnvMonVoltageStatusValue may obtain before an emergency shutdown of the managed device is initiated.

ciscoEnvMonVoltageLastShutdown

1.3.6.1.4.1.9.9.13.1.2.1.6

Integer32 · millivolts

The value of the associated instance of the object ciscoEnvMonVoltageStatusValue at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown.

ciscoEnvMonVoltageState

1.3.6.1.4.1.9.9.13.1.2.1.7

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the testpoint being instrumented.

ciscoEnvMonTemperatureStatusTable

1.3.6.1.4.1.9.9.13.1.3

Index: ciscoEnvMonTemperatureStatusIndex

The table of ambient temperature status maintained by the environmental monitor.

ciscoEnvMonTemperatureStatusIndex

1.3.6.1.4.1.9.9.13.1.3.1.1

Integer32 (0..2147483647)

Unique index for the testpoint being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.

ciscoEnvMonTemperatureStatusDescr

1.3.6.1.4.1.9.9.13.1.3.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonTemperatureStatusValue

1.3.6.1.4.1.9.9.13.1.3.1.3

Gauge32 · degrees Celsius

The current measurement of the testpoint being instrumented. The object ciscoEnvMonTemperatureStatusValueRev1 should be used to read the temperature.

ciscoEnvMonTemperatureThreshold

1.3.6.1.4.1.9.9.13.1.3.1.4

Integer32 · degrees Celsius

The highest value that the associated instance of the object ciscoEnvMonTemperatureStatusValueRev1 may obtain before an emergency shutdown of the managed device is initiated.

ciscoEnvMonTemperatureLastShutdown

1.3.6.1.4.1.9.9.13.1.3.1.5

Integer32 · degrees Celsius

The value of the associated instance of the object ciscoEnvMonTemperatureStatusValueRev1 at the time an emergency shutdown of the managed device was last initiated. This value is stored in non-volatile RAM and hence is able to survive the shutdown.

ciscoEnvMonTemperatureState

1.3.6.1.4.1.9.9.13.1.3.1.6

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the testpoint being instrumented.

ciscoEnvMonTemperatureStatusValueRev1

1.3.6.1.4.1.9.9.13.1.3.1.7

Integer32 · degrees Celsius

The current measurement of the testpoint being instrumented.It also accomodates negative temperature values.

ciscoEnvMonFanStatusTable

1.3.6.1.4.1.9.9.13.1.4

Index: ciscoEnvMonFanStatusIndex

The table of fan status maintained by the environmental monitor.

ciscoEnvMonFanStatusIndex

1.3.6.1.4.1.9.9.13.1.4.1.1

Integer32 (0..2147483647)

Unique index for the fan being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.

ciscoEnvMonFanStatusDescr

1.3.6.1.4.1.9.9.13.1.4.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonFanState

1.3.6.1.4.1.9.9.13.1.4.1.3

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the fan being instrumented.

ciscoEnvMonSupplyStatusTable

1.3.6.1.4.1.9.9.13.1.5

Index: ciscoEnvMonSupplyStatusIndex

The table of power supply status maintained by the environmental monitor card.

ciscoEnvMonSupplyStatusIndex

1.3.6.1.4.1.9.9.13.1.5.1.1

Integer32 (0..2147483647)

Unique index for the power supply being instrumented. This index is for SNMP purposes only, and has no intrinsic meaning.

ciscoEnvMonSupplyStatusDescr

1.3.6.1.4.1.9.9.13.1.5.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonSupplyState

1.3.6.1.4.1.9.9.13.1.5.1.3

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the power supply being instrumented.

ciscoEnvMonSupplySource

1.3.6.1.4.1.9.9.13.1.5.1.4

INTEGER1 = unknown2 = ac3 = dc4 = externalPowerSupply5 = internalRedundant · Integer32

The power supply source. unknown - Power supply source unknown ac - AC power supply dc - DC power supply externalPowerSupply - External power supply internalRedundant - Internal redundant power supply

Trap details

ciscoEnvMonShutdownNotification

1.3.6.1.4.1.9.9.13.3.0.1

A ciscoEnvMonShutdownNotification is sent if the environmental monitor detects a testpoint reaching a critical state and is about to initiate a shutdown. This notification contains no objects so that it may be encoded and sent in the shortest amount of time possible. Even so, management applications should not rely on receiving such a notification as it may not be sent before the shutdown completes.

ciscoEnvMonVoltageNotification

1.3.6.1.4.1.9.9.13.3.0.2

A ciscoEnvMonVoltageNotification is sent if the voltage measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonVoltStatusChangeNotif.

ciscoEnvMonVoltageStatusDescr

1.3.6.1.4.1.9.9.13.1.2.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonVoltageStatusValue

1.3.6.1.4.1.9.9.13.1.2.1.3

CiscoSignedGaugeRepresents the current value of an entity, as a signed integer. · Integer32 · millivolts

The current measurement of the testpoint being instrumented.

ciscoEnvMonVoltageState

1.3.6.1.4.1.9.9.13.1.2.1.7

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the testpoint being instrumented.

ciscoEnvMonTemperatureNotification

1.3.6.1.4.1.9.9.13.3.0.3

A ciscoEnvMonTemperatureNotification is sent if the temperature measured at a given testpoint is outside the normal range for the testpoint (i.e. is at the warning, critical, or shutdown stage). Since such a Notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonTempStatusChangeNotif.

ciscoEnvMonTemperatureStatusDescr

1.3.6.1.4.1.9.9.13.1.3.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonTemperatureStatusValue

1.3.6.1.4.1.9.9.13.1.3.1.3

Gauge32 · degrees Celsius

The current measurement of the testpoint being instrumented. The object ciscoEnvMonTemperatureStatusValueRev1 should be used to read the temperature.

ciscoEnvMonTemperatureState

1.3.6.1.4.1.9.9.13.1.3.1.6

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the testpoint being instrumented.

ciscoEnvMonTemperatureStatusValueRev1

1.3.6.1.4.1.9.9.13.1.3.1.7

Integer32 · degrees Celsius

The current measurement of the testpoint being instrumented.It also accomodates negative temperature values.

ciscoEnvMonFanNotification

1.3.6.1.4.1.9.9.13.3.0.4

A ciscoEnvMonFanNotification is sent if any one of the fans in the fan array (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonFanStatusChangeNotif.

ciscoEnvMonFanStatusDescr

1.3.6.1.4.1.9.9.13.1.4.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonFanState

1.3.6.1.4.1.9.9.13.1.4.1.3

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the fan being instrumented.

ciscoEnvMonRedundantSupplyNotification

1.3.6.1.4.1.9.9.13.3.0.5

A ciscoEnvMonRedundantSupplyNotification is sent if the redundant power supply (where extant) fails. Since such a notification is usually generated before the shutdown state is reached, it can convey more data and has a better chance of being sent than does the ciscoEnvMonShutdownNotification. This notification is deprecated in favour of ciscoEnvMonSuppStatusChangeNotif.

ciscoEnvMonSupplyStatusDescr

1.3.6.1.4.1.9.9.13.1.5.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonSupplyState

1.3.6.1.4.1.9.9.13.1.5.1.3

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the power supply being instrumented.

ciscoEnvMonVoltStatusChangeNotif

1.3.6.1.4.1.9.9.13.3.0.6

A ciscoEnvMonVoltStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonVoltageState.

ciscoEnvMonVoltageStatusDescr

1.3.6.1.4.1.9.9.13.1.2.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonVoltageStatusValue

1.3.6.1.4.1.9.9.13.1.2.1.3

CiscoSignedGaugeRepresents the current value of an entity, as a signed integer. · Integer32 · millivolts

The current measurement of the testpoint being instrumented.

ciscoEnvMonVoltageState

1.3.6.1.4.1.9.9.13.1.2.1.7

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the testpoint being instrumented.

ciscoEnvMonTempStatusChangeNotif

1.3.6.1.4.1.9.9.13.3.0.7

A ciscoEnvMonTempStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonTemperatureState.

ciscoEnvMonTemperatureStatusDescr

1.3.6.1.4.1.9.9.13.1.3.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the testpoint being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonTemperatureStatusValue

1.3.6.1.4.1.9.9.13.1.3.1.3

Gauge32 · degrees Celsius

The current measurement of the testpoint being instrumented. The object ciscoEnvMonTemperatureStatusValueRev1 should be used to read the temperature.

ciscoEnvMonTemperatureState

1.3.6.1.4.1.9.9.13.1.3.1.6

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the testpoint being instrumented.

ciscoEnvMonTemperatureStatusValueRev1

1.3.6.1.4.1.9.9.13.1.3.1.7

Integer32 · degrees Celsius

The current measurement of the testpoint being instrumented.It also accomodates negative temperature values.

ciscoEnvMonFanStatusChangeNotif

1.3.6.1.4.1.9.9.13.3.0.8

A ciscoEnvMonFanStatusChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonFanState.

ciscoEnvMonFanStatusDescr

1.3.6.1.4.1.9.9.13.1.4.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the fan being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonFanState

1.3.6.1.4.1.9.9.13.1.4.1.3

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the fan being instrumented.

ciscoEnvMonSuppStatusChangeNotif

1.3.6.1.4.1.9.9.13.3.0.9

A ciscoEnvMonSupplyStatChangeNotif is sent if there is change in the state of a device being monitored by ciscoEnvMonSupplyState.

ciscoEnvMonSupplyStatusDescr

1.3.6.1.4.1.9.9.13.1.5.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

Textual description of the power supply being instrumented. This description is a short textual label, suitable as a human-sensible identification for the rest of the information in the entry.

ciscoEnvMonSupplyState

1.3.6.1.4.1.9.9.13.1.5.1.3

CiscoEnvMonState1 = normal2 = warning3 = critical4 = shutdown5 = notPresent6 = notFunctioningRepresents the state of a device being monitored. Valid values are: normal(1): the environment is good, such as low temperature. warning(2): the environment is bad, such as temperature above normal operation range but not too high. critical(3): the environment is very bad, such as temperature much higher than normal operation limit. shutdown(4): the environment is the worst, the system should be shutdown immediately. notPresent(5): the environmental monitor is not present, such as temperature sensors do not exist. notFunctioning(6): the environmental monitor does not function properly, such as a temperature sensor generates a abnormal data like 1000 C. · Integer32

The current state of the power supply being instrumented.

↑ To TOC