EZ5 MIB Catalog

CISCO-FIREPOWER-AP-FIRMWARE-MIB

2023-01-25

MIB representation of the Cisco Firepower FIRMWARE management information model package

Download CISCO-FIREPOWER-AP-FIRMWARE-MIB.txt Open CISCO-FIREPOWER-AP-FIRMWARE-MIB.txt in a new tab

TABLES (71)

Tables (71)

NameOID
cfprApFirmwareAckTable1.3.6.1.4.1.9.9.826.2.1.30.1
cfprApFirmwareAutoSyncPolicyTable1.3.6.1.4.1.9.9.826.2.1.30.2
cfprApFirmwareBladeTable1.3.6.1.4.1.9.9.826.2.1.30.3
cfprApFirmwareBootDefinitionTable1.3.6.1.4.1.9.9.826.2.1.30.4
cfprApFirmwareBootUnitTable1.3.6.1.4.1.9.9.826.2.1.30.5
cfprApFirmwareBundleInfoTable1.3.6.1.4.1.9.9.826.2.1.30.6
cfprApFirmwareBundleInfoDigestTable1.3.6.1.4.1.9.9.826.2.1.30.7
cfprApFirmwareBundleTypeTable1.3.6.1.4.1.9.9.826.2.1.30.8
cfprApFirmwareBundleTypeCapProviderTable1.3.6.1.4.1.9.9.826.2.1.30.9
cfprApFirmwareCatalogPackTable1.3.6.1.4.1.9.9.826.2.1.30.10
cfprApFirmwareCatalogueTable1.3.6.1.4.1.9.9.826.2.1.30.11
cfprApFirmwareCompSourceTable1.3.6.1.4.1.9.9.826.2.1.30.12
cfprApFirmwareCompTargetTable1.3.6.1.4.1.9.9.826.2.1.30.13
cfprApFirmwareComputeHostPackTable1.3.6.1.4.1.9.9.826.2.1.30.14
cfprApFirmwareComputeMgmtPackTable1.3.6.1.4.1.9.9.826.2.1.30.15
cfprApFirmwareConstraintTable1.3.6.1.4.1.9.9.826.2.1.30.16
cfprApFirmwareConstraintsTable1.3.6.1.4.1.9.9.826.2.1.30.17
cfprApFirmwareCspAppListTable1.3.6.1.4.1.9.9.826.2.1.30.18
cfprApFirmwareCspVersionTable1.3.6.1.4.1.9.9.826.2.1.30.19
cfprApFirmwareDependencyTable1.3.6.1.4.1.9.9.826.2.1.30.20
cfprApFirmwareDistCspBlackListTable1.3.6.1.4.1.9.9.826.2.1.30.21
cfprApFirmwareDistImageTable1.3.6.1.4.1.9.9.826.2.1.30.22
cfprApFirmwareDistributableTable1.3.6.1.4.1.9.9.826.2.1.30.23
cfprApFirmwareDistributableFsmTable1.3.6.1.4.1.9.9.826.2.1.30.24
cfprApFirmwareDistributableFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.25
cfprApFirmwareDistributableFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.26
cfprApFirmwareDownloaderTable1.3.6.1.4.1.9.9.826.2.1.30.27
cfprApFirmwareDownloaderFsmTable1.3.6.1.4.1.9.9.826.2.1.30.28
cfprApFirmwareDownloaderFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.29
cfprApFirmwareDownloaderFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.30
cfprApFirmwareHostTable1.3.6.1.4.1.9.9.826.2.1.30.31
cfprApFirmwareHostPackModImpactTable1.3.6.1.4.1.9.9.826.2.1.30.32
cfprApFirmwareImageTable1.3.6.1.4.1.9.9.826.2.1.30.33
cfprApFirmwareImageFsmTable1.3.6.1.4.1.9.9.826.2.1.30.34
cfprApFirmwareImageFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.35
cfprApFirmwareImageFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.36
cfprApFirmwareImageLockTable1.3.6.1.4.1.9.9.826.2.1.30.37
cfprApFirmwareInfraTable1.3.6.1.4.1.9.9.826.2.1.30.38
cfprApFirmwareInfraPackTable1.3.6.1.4.1.9.9.826.2.1.30.39
cfprApFirmwareInfraPackFsmTable1.3.6.1.4.1.9.9.826.2.1.30.40
cfprApFirmwareInfraPackFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.41
cfprApFirmwareInfraPackFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.42
cfprApFirmwareInstallImpactTable1.3.6.1.4.1.9.9.826.2.1.30.43
cfprApFirmwareInstallableTable1.3.6.1.4.1.9.9.826.2.1.30.44
cfprApFirmwarePackItemTable1.3.6.1.4.1.9.9.826.2.1.30.45
cfprApFirmwarePlatformTable1.3.6.1.4.1.9.9.826.2.1.30.46
cfprApFirmwarePlatformBundleTypeCapProviderTable1.3.6.1.4.1.9.9.826.2.1.30.47
cfprApFirmwarePlatformPackTable1.3.6.1.4.1.9.9.826.2.1.30.48
cfprApFirmwarePlatformPackFsmTable1.3.6.1.4.1.9.9.826.2.1.30.49
cfprApFirmwarePlatformPackFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.50
cfprApFirmwarePlatformPackFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.51
cfprApFirmwareRackTable1.3.6.1.4.1.9.9.826.2.1.30.52
cfprApFirmwareRommonInfoTable1.3.6.1.4.1.9.9.826.2.1.30.53
cfprApFirmwareRunningTable1.3.6.1.4.1.9.9.826.2.1.30.54
cfprApFirmwareSpecTable1.3.6.1.4.1.9.9.826.2.1.30.55
cfprApFirmwareStatusTable1.3.6.1.4.1.9.9.826.2.1.30.56
cfprApFirmwareSupFirmwareTable1.3.6.1.4.1.9.9.826.2.1.30.57
cfprApFirmwareSupFirmwareFsmTable1.3.6.1.4.1.9.9.826.2.1.30.58
cfprApFirmwareSupFirmwareFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.59
cfprApFirmwareSupFirmwareFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.60
cfprApFirmwareSystemTable1.3.6.1.4.1.9.9.826.2.1.30.61
cfprApFirmwareSystemCompCheckResultTable1.3.6.1.4.1.9.9.826.2.1.30.62
cfprApFirmwareSystemFsmTable1.3.6.1.4.1.9.9.826.2.1.30.63
cfprApFirmwareSystemFsmStageTable1.3.6.1.4.1.9.9.826.2.1.30.64
cfprApFirmwareSystemFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.30.65
cfprApFirmwareTypeTable1.3.6.1.4.1.9.9.826.2.1.30.66
cfprApFirmwareUcscInfoTable1.3.6.1.4.1.9.9.826.2.1.30.67
cfprApFirmwareUpdatableTable1.3.6.1.4.1.9.9.826.2.1.30.68
cfprApFirmwareUpgradeConstraintTable1.3.6.1.4.1.9.9.826.2.1.30.69
cfprApFirmwareUpgradeDetailTable1.3.6.1.4.1.9.9.826.2.1.30.70
cfprApFirmwareUpgradeInfoTable1.3.6.1.4.1.9.9.826.2.1.30.71

END OF TOC

Table details

cfprApFirmwareAckTable

1.3.6.1.4.1.9.9.826.2.1.30.1

Index: cfprApFirmwareAckInstanceId

Cisco Firepower firmware:Ack managed object table

cfprApFirmwareAckInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.1.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareAckDn

1.3.6.1.4.1.9.9.826.2.1.30.1.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Ack:dn managed object property

cfprApFirmwareAckRn

1.3.6.1.4.1.9.9.826.2.1.30.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:rn managed object property

cfprApFirmwareAckAcked

1.3.6.1.4.1.9.9.826.2.1.30.1.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Ack:acked managed object property

cfprApFirmwareAckAckedBy

1.3.6.1.4.1.9.9.826.2.1.30.1.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:ackedBy managed object property

cfprApFirmwareAckAdminState

1.3.6.1.4.1.9.9.826.2.1.30.1.1.6

CfprApTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower firmware:Ack:adminState managed object property

cfprApFirmwareAckAutoDelete

1.3.6.1.4.1.9.9.826.2.1.30.1.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Ack:autoDelete managed object property

cfprApFirmwareAckChangeBy

1.3.6.1.4.1.9.9.826.2.1.30.1.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:changeBy managed object property

cfprApFirmwareAckChangeDetails

1.3.6.1.4.1.9.9.826.2.1.30.1.1.9

CfprApTrigAckChangeDetails · BITS

Cisco Firepower firmware:Ack:changeDetails managed object property

cfprApFirmwareAckChanges

1.3.6.1.4.1.9.9.826.2.1.30.1.1.10

CfprApTrigAckChanges · BITS

Cisco Firepower firmware:Ack:changes managed object property

cfprApFirmwareAckDescr

1.3.6.1.4.1.9.9.826.2.1.30.1.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:descr managed object property

cfprApFirmwareAckDisr

1.3.6.1.4.1.9.9.826.2.1.30.1.1.12

CfprApTrigAckDisr · BITS

Cisco Firepower firmware:Ack:disr managed object property

cfprApFirmwareAckIgnoreCap

1.3.6.1.4.1.9.9.826.2.1.30.1.1.13

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Ack:ignoreCap managed object property

cfprApFirmwareAckIntId

1.3.6.1.4.1.9.9.826.2.1.30.1.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:intId managed object property

cfprApFirmwareAckModified

1.3.6.1.4.1.9.9.826.2.1.30.1.1.15

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Ack:modified managed object property

cfprApFirmwareAckName

1.3.6.1.4.1.9.9.826.2.1.30.1.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:name managed object property

cfprApFirmwareAckOperScheduler

1.3.6.1.4.1.9.9.826.2.1.30.1.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:operScheduler managed object property

cfprApFirmwareAckOperState

1.3.6.1.4.1.9.9.826.2.1.30.1.1.18

CfprApTrigAckOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower firmware:Ack:operState managed object property

cfprApFirmwareAckPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.1.1.19

Gauge32

Cisco Firepower firmware:Ack:policyLevel managed object property

cfprApFirmwareAckPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.1.1.20

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:Ack:policyOwner managed object property

cfprApFirmwareAckPrevOperState

1.3.6.1.4.1.9.9.826.2.1.30.1.1.21

CfprApTrigAckPrevOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower firmware:Ack:prevOperState managed object property

cfprApFirmwareAckScheduler

1.3.6.1.4.1.9.9.826.2.1.30.1.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Ack:scheduler managed object property

cfprApFirmwareAutoSyncPolicyTable

1.3.6.1.4.1.9.9.826.2.1.30.2

Index: cfprApFirmwareAutoSyncPolicyInstanceId

Cisco Firepower firmware:AutoSyncPolicy managed object table

cfprApFirmwareAutoSyncPolicyInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.2.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareAutoSyncPolicyDn

1.3.6.1.4.1.9.9.826.2.1.30.2.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:AutoSyncPolicy:dn managed object property

cfprApFirmwareAutoSyncPolicyRn

1.3.6.1.4.1.9.9.826.2.1.30.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:AutoSyncPolicy:rn managed object property

cfprApFirmwareAutoSyncPolicyConfigIssue

1.3.6.1.4.1.9.9.826.2.1.30.2.1.4

CfprApFirmwareAutoSyncConfigIssue0 = noIssues1 = defaultPackageMissing2 = versionsEmptyInDefaultPackage · Integer32

Cisco Firepower firmware:AutoSyncPolicy:configIssue managed object property

cfprApFirmwareAutoSyncPolicyDescr

1.3.6.1.4.1.9.9.826.2.1.30.2.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:AutoSyncPolicy:descr managed object property

cfprApFirmwareAutoSyncPolicyIntId

1.3.6.1.4.1.9.9.826.2.1.30.2.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:AutoSyncPolicy:intId managed object property

cfprApFirmwareAutoSyncPolicyName

1.3.6.1.4.1.9.9.826.2.1.30.2.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:AutoSyncPolicy:name managed object property

cfprApFirmwareAutoSyncPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.2.1.8

Gauge32

Cisco Firepower firmware:AutoSyncPolicy:policyLevel managed object property

cfprApFirmwareAutoSyncPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.2.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:AutoSyncPolicy:policyOwner managed object property

cfprApFirmwareAutoSyncPolicySyncState

1.3.6.1.4.1.9.9.826.2.1.30.2.1.10

CfprApFirmwareAutoSyncState0 = autoAcknowledge1 = userAcknowledge2 = noActions · Integer32

Cisco Firepower firmware:AutoSyncPolicy:syncState managed object property

cfprApFirmwareBladeTable

1.3.6.1.4.1.9.9.826.2.1.30.3

Index: cfprApFirmwareBladeInstanceId

Cisco Firepower firmware:Blade managed object table

cfprApFirmwareBladeInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.3.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBladeDn

1.3.6.1.4.1.9.9.826.2.1.30.3.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Blade:dn managed object property

cfprApFirmwareBladeRn

1.3.6.1.4.1.9.9.826.2.1.30.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Blade:rn managed object property

cfprApFirmwareBladeOperVersion

1.3.6.1.4.1.9.9.826.2.1.30.3.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Blade:operVersion managed object property

cfprApFirmwareBootDefinitionTable

1.3.6.1.4.1.9.9.826.2.1.30.4

Index: cfprApFirmwareBootDefinitionInstanceId

Cisco Firepower firmware:BootDefinition managed object table

cfprApFirmwareBootDefinitionInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.4.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBootDefinitionDn

1.3.6.1.4.1.9.9.826.2.1.30.4.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:BootDefinition:dn managed object property

cfprApFirmwareBootDefinitionRn

1.3.6.1.4.1.9.9.826.2.1.30.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BootDefinition:rn managed object property

cfprApFirmwareBootDefinitionType

1.3.6.1.4.1.9.9.826.2.1.30.4.1.4

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:BootDefinition:type managed object property

cfprApFirmwareBootUnitTable

1.3.6.1.4.1.9.9.826.2.1.30.5

Index: cfprApFirmwareBootUnitInstanceId

Cisco Firepower firmware:BootUnit managed object table

cfprApFirmwareBootUnitInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.5.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBootUnitDn

1.3.6.1.4.1.9.9.826.2.1.30.5.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:BootUnit:dn managed object property

cfprApFirmwareBootUnitRn

1.3.6.1.4.1.9.9.826.2.1.30.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BootUnit:rn managed object property

cfprApFirmwareBootUnitAdminState

1.3.6.1.4.1.9.9.826.2.1.30.5.1.4

CfprApFirmwareTriggerState0 = triggered1 = trigger · Integer32

Cisco Firepower firmware:BootUnit:adminState managed object property

cfprApFirmwareBootUnitIgnoreCompCheck

1.3.6.1.4.1.9.9.826.2.1.30.5.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:BootUnit:ignoreCompCheck managed object property

cfprApFirmwareBootUnitImage

1.3.6.1.4.1.9.9.826.2.1.30.5.1.6

CfprApFirmwareBootUnitImage0 = running1 = backup · Integer32

Cisco Firepower firmware:BootUnit:image managed object property

cfprApFirmwareBootUnitInvTag

1.3.6.1.4.1.9.9.826.2.1.30.5.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BootUnit:invTag managed object property

cfprApFirmwareBootUnitMode

1.3.6.1.4.1.9.9.826.2.1.30.5.1.8

CfprApFirmwareBootUnitMode0 = install1 = upgrade · Integer32

Cisco Firepower firmware:BootUnit:mode managed object property

cfprApFirmwareBootUnitOperState

1.3.6.1.4.1.9.9.826.2.1.30.5.1.9

CfprApFirmwareImageState0 = ready1 = scheduled2 = updating3 = activating4 = failed5 = setStartup6 = rebooting7 = pendingNextBoot8 = throttled9 = upgrading10 = autoUpdating11 = autoActivating12 = pendingPowerCycle13 = badImage14 = rebuilding · Integer32

Cisco Firepower firmware:BootUnit:operState managed object property

cfprApFirmwareBootUnitPrevVersion

1.3.6.1.4.1.9.9.826.2.1.30.5.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BootUnit:prevVersion managed object property

cfprApFirmwareBootUnitResetOnActivate

1.3.6.1.4.1.9.9.826.2.1.30.5.1.11

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:BootUnit:resetOnActivate managed object property

cfprApFirmwareBootUnitSkipValidation

1.3.6.1.4.1.9.9.826.2.1.30.5.1.12

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:BootUnit:skipValidation managed object property

cfprApFirmwareBootUnitType

1.3.6.1.4.1.9.9.826.2.1.30.5.1.13

CfprApFirmwareComponentType · BITS

Cisco Firepower firmware:BootUnit:type managed object property

cfprApFirmwareBootUnitVersion

1.3.6.1.4.1.9.9.826.2.1.30.5.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BootUnit:version managed object property

cfprApFirmwareBundleInfoTable

1.3.6.1.4.1.9.9.826.2.1.30.6

Index: cfprApFirmwareBundleInfoInstanceId

Cisco Firepower firmware:BundleInfo managed object table

cfprApFirmwareBundleInfoInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.6.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBundleInfoDn

1.3.6.1.4.1.9.9.826.2.1.30.6.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:BundleInfo:dn managed object property

cfprApFirmwareBundleInfoRn

1.3.6.1.4.1.9.9.826.2.1.30.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleInfo:rn managed object property

cfprApFirmwareBundleInfoType

1.3.6.1.4.1.9.9.826.2.1.30.6.1.4

CfprApFirmwareDistributableType0 = unknown1 = image2 = fullBundle3 = infrastructureBundle4 = bSeriesBundle5 = cSeriesBundle6 = catalog7 = platformBundle8 = firmwareFpr9kBundle9 = firmwareFpr4kBundle10 = appBundle · Integer32

Cisco Firepower firmware:BundleInfo:type managed object property

cfprApFirmwareBundleInfoVersion

1.3.6.1.4.1.9.9.826.2.1.30.6.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleInfo:version managed object property

cfprApFirmwareBundleInfoDigestTable

1.3.6.1.4.1.9.9.826.2.1.30.7

Index: cfprApFirmwareBundleInfoDigestInstanceId

Cisco Firepower firmware:BundleInfoDigest managed object table

cfprApFirmwareBundleInfoDigestInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.7.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBundleInfoDigestDn

1.3.6.1.4.1.9.9.826.2.1.30.7.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:BundleInfoDigest:dn managed object property

cfprApFirmwareBundleInfoDigestRn

1.3.6.1.4.1.9.9.826.2.1.30.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleInfoDigest:rn managed object property

cfprApFirmwareBundleInfoDigestBundleName

1.3.6.1.4.1.9.9.826.2.1.30.7.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleInfoDigest:bundleName managed object property

cfprApFirmwareBundleInfoDigestType

1.3.6.1.4.1.9.9.826.2.1.30.7.1.5

CfprApFirmwareDistributableType0 = unknown1 = image2 = fullBundle3 = infrastructureBundle4 = bSeriesBundle5 = cSeriesBundle6 = catalog7 = platformBundle8 = firmwareFpr9kBundle9 = firmwareFpr4kBundle10 = appBundle · Integer32

Cisco Firepower firmware:BundleInfoDigest:type managed object property

cfprApFirmwareBundleInfoDigestVersion

1.3.6.1.4.1.9.9.826.2.1.30.7.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleInfoDigest:version managed object property

cfprApFirmwareBundleTypeTable

1.3.6.1.4.1.9.9.826.2.1.30.8

Index: cfprApFirmwareBundleTypeInstanceId

Cisco Firepower firmware:BundleType managed object table

cfprApFirmwareBundleTypeInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.8.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBundleTypeDn

1.3.6.1.4.1.9.9.826.2.1.30.8.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:BundleType:dn managed object property

cfprApFirmwareBundleTypeRn

1.3.6.1.4.1.9.9.826.2.1.30.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleType:rn managed object property

cfprApFirmwareBundleTypeInvTag

1.3.6.1.4.1.9.9.826.2.1.30.8.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleType:invTag managed object property

cfprApFirmwareBundleTypeType

1.3.6.1.4.1.9.9.826.2.1.30.8.1.5

CfprApFirmwareDistributableType0 = unknown1 = image2 = fullBundle3 = infrastructureBundle4 = bSeriesBundle5 = cSeriesBundle6 = catalog7 = platformBundle8 = firmwareFpr9kBundle9 = firmwareFpr4kBundle10 = appBundle · Integer32

Cisco Firepower firmware:BundleType:type managed object property

cfprApFirmwareBundleTypeCapProviderTable

1.3.6.1.4.1.9.9.826.2.1.30.9

Index: cfprApFirmwareBundleTypeCapProviderInstanceId

Cisco Firepower firmware:BundleTypeCapProvider managed object table

cfprApFirmwareBundleTypeCapProviderInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.9.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareBundleTypeCapProviderDn

1.3.6.1.4.1.9.9.826.2.1.30.9.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:BundleTypeCapProvider:dn managed object property

cfprApFirmwareBundleTypeCapProviderRn

1.3.6.1.4.1.9.9.826.2.1.30.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleTypeCapProvider:rn managed object property

cfprApFirmwareBundleTypeCapProviderDeleted

1.3.6.1.4.1.9.9.826.2.1.30.9.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:BundleTypeCapProvider:deleted managed object property

cfprApFirmwareBundleTypeCapProviderDeprecated

1.3.6.1.4.1.9.9.826.2.1.30.9.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:BundleTypeCapProvider:deprecated managed object property

cfprApFirmwareBundleTypeCapProviderElementLoadFailures

1.3.6.1.4.1.9.9.826.2.1.30.9.1.6

Gauge32

Cisco Firepower firmware:BundleTypeCapProvider:elementLoadFailure s managed object property

cfprApFirmwareBundleTypeCapProviderElementsLoaded

1.3.6.1.4.1.9.9.826.2.1.30.9.1.7

Gauge32

Cisco Firepower firmware:BundleTypeCapProvider:elementsLoaded managed object property

cfprApFirmwareBundleTypeCapProviderGencount

1.3.6.1.4.1.9.9.826.2.1.30.9.1.8

Gauge32

Cisco Firepower firmware:BundleTypeCapProvider:gencount managed object property

cfprApFirmwareBundleTypeCapProviderLoadErrors

1.3.6.1.4.1.9.9.826.2.1.30.9.1.9

Gauge32

Cisco Firepower firmware:BundleTypeCapProvider:loadErrors managed object property

cfprApFirmwareBundleTypeCapProviderLoadWarnings

1.3.6.1.4.1.9.9.826.2.1.30.9.1.10

Gauge32

Cisco Firepower firmware:BundleTypeCapProvider:loadWarnings managed object property

cfprApFirmwareBundleTypeCapProviderMgmtPlaneVer

1.3.6.1.4.1.9.9.826.2.1.30.9.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleTypeCapProvider:mgmtPlaneVer managed object property

cfprApFirmwareBundleTypeCapProviderModel

1.3.6.1.4.1.9.9.826.2.1.30.9.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleTypeCapProvider:model managed object property

cfprApFirmwareBundleTypeCapProviderPlatformType

1.3.6.1.4.1.9.9.826.2.1.30.9.1.13

CfprApFirmwarePlatformType0 = ucs1 = ucsMini2 = sspBakerstreet3 = fpr2100 · Integer32

Cisco Firepower firmware:BundleTypeCapProvider:platformType managed object property

cfprApFirmwareBundleTypeCapProviderVendor

1.3.6.1.4.1.9.9.826.2.1.30.9.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:BundleTypeCapProvider:vendor managed object property

cfprApFirmwareCatalogPackTable

1.3.6.1.4.1.9.9.826.2.1.30.10

Index: cfprApFirmwareCatalogPackInstanceId

Cisco Firepower firmware:CatalogPack managed object table

cfprApFirmwareCatalogPackInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.10.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareCatalogPackDn

1.3.6.1.4.1.9.9.826.2.1.30.10.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:CatalogPack:dn managed object property

cfprApFirmwareCatalogPackRn

1.3.6.1.4.1.9.9.826.2.1.30.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:rn managed object property

cfprApFirmwareCatalogPackCatalogName

1.3.6.1.4.1.9.9.826.2.1.30.10.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:catalogName managed object property

cfprApFirmwareCatalogPackCatalogVersion

1.3.6.1.4.1.9.9.826.2.1.30.10.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:catalogVersion managed object property

cfprApFirmwareCatalogPackConfigState

1.3.6.1.4.1.9.9.826.2.1.30.10.1.6

CfprApFirmwareCatalogPackConfigState0 = ok1 = notApplied2 = failed · Integer32

Cisco Firepower firmware:CatalogPack:configState managed object property

cfprApFirmwareCatalogPackConfigStatusMessage

1.3.6.1.4.1.9.9.826.2.1.30.10.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:configStatusMessage managed object property

cfprApFirmwareCatalogPackDescr

1.3.6.1.4.1.9.9.826.2.1.30.10.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:descr managed object property

cfprApFirmwareCatalogPackIntId

1.3.6.1.4.1.9.9.826.2.1.30.10.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:intId managed object property

cfprApFirmwareCatalogPackMode

1.3.6.1.4.1.9.9.826.2.1.30.10.1.10

CfprApFirmwarePackMode0 = staged1 = oneShot · Integer32

Cisco Firepower firmware:CatalogPack:mode managed object property

cfprApFirmwareCatalogPackName

1.3.6.1.4.1.9.9.826.2.1.30.10.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CatalogPack:name managed object property

cfprApFirmwareCatalogPackPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.10.1.12

Gauge32

Cisco Firepower firmware:CatalogPack:policyLevel managed object property

cfprApFirmwareCatalogPackPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.10.1.13

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:CatalogPack:policyOwner managed object property

cfprApFirmwareCatalogPackStageSize

1.3.6.1.4.1.9.9.826.2.1.30.10.1.14

Gauge32

Cisco Firepower firmware:CatalogPack:stageSize managed object property

cfprApFirmwareCatalogPackUpdateTrigger

1.3.6.1.4.1.9.9.826.2.1.30.10.1.15

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:CatalogPack:updateTrigger managed object property

cfprApFirmwareCatalogueTable

1.3.6.1.4.1.9.9.826.2.1.30.11

Index: cfprApFirmwareCatalogueInstanceId

Cisco Firepower firmware:Catalogue managed object table

cfprApFirmwareCatalogueInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.11.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareCatalogueDn

1.3.6.1.4.1.9.9.826.2.1.30.11.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Catalogue:dn managed object property

cfprApFirmwareCatalogueRn

1.3.6.1.4.1.9.9.826.2.1.30.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Catalogue:rn managed object property

cfprApFirmwareCatalogueSyncTrigger

1.3.6.1.4.1.9.9.826.2.1.30.11.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Catalogue:syncTrigger managed object property

cfprApFirmwareCompSourceTable

1.3.6.1.4.1.9.9.826.2.1.30.12

Index: cfprApFirmwareCompSourceInstanceId

Cisco Firepower firmware:CompSource managed object table

cfprApFirmwareCompSourceInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.12.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareCompSourceDn

1.3.6.1.4.1.9.9.826.2.1.30.12.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:CompSource:dn managed object property

cfprApFirmwareCompSourceRn

1.3.6.1.4.1.9.9.826.2.1.30.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompSource:rn managed object property

cfprApFirmwareCompSourceDescr

1.3.6.1.4.1.9.9.826.2.1.30.12.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompSource:descr managed object property

cfprApFirmwareCompSourceIntId

1.3.6.1.4.1.9.9.826.2.1.30.12.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompSource:intId managed object property

cfprApFirmwareCompSourceInvTag

1.3.6.1.4.1.9.9.826.2.1.30.12.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompSource:invTag managed object property

cfprApFirmwareCompSourceName

1.3.6.1.4.1.9.9.826.2.1.30.12.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompSource:name managed object property

cfprApFirmwareCompSourcePolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.12.1.8

Gauge32

Cisco Firepower firmware:CompSource:policyLevel managed object property

cfprApFirmwareCompSourcePolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.12.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:CompSource:policyOwner managed object property

cfprApFirmwareCompSourceVersion

1.3.6.1.4.1.9.9.826.2.1.30.12.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompSource:version managed object property

cfprApFirmwareCompTargetTable

1.3.6.1.4.1.9.9.826.2.1.30.13

Index: cfprApFirmwareCompTargetInstanceId

Cisco Firepower firmware:CompTarget managed object table

cfprApFirmwareCompTargetInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.13.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareCompTargetDn

1.3.6.1.4.1.9.9.826.2.1.30.13.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:CompTarget:dn managed object property

cfprApFirmwareCompTargetRn

1.3.6.1.4.1.9.9.826.2.1.30.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompTarget:rn managed object property

cfprApFirmwareCompTargetDescr

1.3.6.1.4.1.9.9.826.2.1.30.13.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompTarget:descr managed object property

cfprApFirmwareCompTargetIntId

1.3.6.1.4.1.9.9.826.2.1.30.13.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompTarget:intId managed object property

cfprApFirmwareCompTargetInvTag

1.3.6.1.4.1.9.9.826.2.1.30.13.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompTarget:invTag managed object property

cfprApFirmwareCompTargetName

1.3.6.1.4.1.9.9.826.2.1.30.13.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompTarget:name managed object property

cfprApFirmwareCompTargetPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.13.1.8

Gauge32

Cisco Firepower firmware:CompTarget:policyLevel managed object property

cfprApFirmwareCompTargetPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.13.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:CompTarget:policyOwner managed object property

cfprApFirmwareCompTargetVersion

1.3.6.1.4.1.9.9.826.2.1.30.13.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CompTarget:version managed object property

cfprApFirmwareComputeHostPackTable

1.3.6.1.4.1.9.9.826.2.1.30.14

Index: cfprApFirmwareComputeHostPackInstanceId

Cisco Firepower firmware:ComputeHostPack managed object table

cfprApFirmwareComputeHostPackInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.14.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareComputeHostPackDn

1.3.6.1.4.1.9.9.826.2.1.30.14.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:ComputeHostPack:dn managed object property

cfprApFirmwareComputeHostPackRn

1.3.6.1.4.1.9.9.826.2.1.30.14.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:rn managed object property

cfprApFirmwareComputeHostPackBladeBundleName

1.3.6.1.4.1.9.9.826.2.1.30.14.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:bladeBundleName managed object property

cfprApFirmwareComputeHostPackBladeBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.14.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:bladeBundleVersion managed object property

cfprApFirmwareComputeHostPackConfigQualifier

1.3.6.1.4.1.9.9.826.2.1.30.14.1.6

CfprApFirmwareHostPackConfigQualifier · BITS

Cisco Firepower firmware:ComputeHostPack:configQualifier managed object property

cfprApFirmwareComputeHostPackDescr

1.3.6.1.4.1.9.9.826.2.1.30.14.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:descr managed object property

cfprApFirmwareComputeHostPackIgnoreCompCheck

1.3.6.1.4.1.9.9.826.2.1.30.14.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:ComputeHostPack:ignoreCompCheck managed object property

cfprApFirmwareComputeHostPackIntId

1.3.6.1.4.1.9.9.826.2.1.30.14.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:intId managed object property

cfprApFirmwareComputeHostPackMode

1.3.6.1.4.1.9.9.826.2.1.30.14.1.10

CfprApFirmwarePackMode0 = staged1 = oneShot · Integer32

Cisco Firepower firmware:ComputeHostPack:mode managed object property

cfprApFirmwareComputeHostPackName

1.3.6.1.4.1.9.9.826.2.1.30.14.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:name managed object property

cfprApFirmwareComputeHostPackPlatformBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.14.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:platformBundleVersion managed object property

cfprApFirmwareComputeHostPackPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.14.1.13

Gauge32

Cisco Firepower firmware:ComputeHostPack:policyLevel managed object property

cfprApFirmwareComputeHostPackPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.14.1.14

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:ComputeHostPack:policyOwner managed object property

cfprApFirmwareComputeHostPackRackBundleName

1.3.6.1.4.1.9.9.826.2.1.30.14.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:rackBundleName managed object property

cfprApFirmwareComputeHostPackRackBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.14.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeHostPack:rackBundleVersion managed object property

cfprApFirmwareComputeHostPackStageSize

1.3.6.1.4.1.9.9.826.2.1.30.14.1.17

Gauge32

Cisco Firepower firmware:ComputeHostPack:stageSize managed object property

cfprApFirmwareComputeHostPackUpdateTrigger

1.3.6.1.4.1.9.9.826.2.1.30.14.1.18

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:ComputeHostPack:updateTrigger managed object property

cfprApFirmwareComputeMgmtPackTable

1.3.6.1.4.1.9.9.826.2.1.30.15

Index: cfprApFirmwareComputeMgmtPackInstanceId

Cisco Firepower firmware:ComputeMgmtPack managed object table

cfprApFirmwareComputeMgmtPackInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.15.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareComputeMgmtPackDn

1.3.6.1.4.1.9.9.826.2.1.30.15.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:ComputeMgmtPack:dn managed object property

cfprApFirmwareComputeMgmtPackRn

1.3.6.1.4.1.9.9.826.2.1.30.15.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeMgmtPack:rn managed object property

cfprApFirmwareComputeMgmtPackDescr

1.3.6.1.4.1.9.9.826.2.1.30.15.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeMgmtPack:descr managed object property

cfprApFirmwareComputeMgmtPackIgnoreCompCheck

1.3.6.1.4.1.9.9.826.2.1.30.15.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:ComputeMgmtPack:ignoreCompCheck managed object property

cfprApFirmwareComputeMgmtPackIntId

1.3.6.1.4.1.9.9.826.2.1.30.15.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeMgmtPack:intId managed object property

cfprApFirmwareComputeMgmtPackMode

1.3.6.1.4.1.9.9.826.2.1.30.15.1.7

CfprApFirmwarePackMode0 = staged1 = oneShot · Integer32

Cisco Firepower firmware:ComputeMgmtPack:mode managed object property

cfprApFirmwareComputeMgmtPackName

1.3.6.1.4.1.9.9.826.2.1.30.15.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ComputeMgmtPack:name managed object property

cfprApFirmwareComputeMgmtPackPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.15.1.9

Gauge32

Cisco Firepower firmware:ComputeMgmtPack:policyLevel managed object property

cfprApFirmwareComputeMgmtPackPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.15.1.10

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:ComputeMgmtPack:policyOwner managed object property

cfprApFirmwareComputeMgmtPackStageSize

1.3.6.1.4.1.9.9.826.2.1.30.15.1.11

Gauge32

Cisco Firepower firmware:ComputeMgmtPack:stageSize managed object property

cfprApFirmwareComputeMgmtPackUpdateTrigger

1.3.6.1.4.1.9.9.826.2.1.30.15.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:ComputeMgmtPack:updateTrigger managed object property

cfprApFirmwareConstraintTable

1.3.6.1.4.1.9.9.826.2.1.30.16

Index: cfprApFirmwareConstraintInstanceId

Cisco Firepower firmware:Constraint managed object table

cfprApFirmwareConstraintInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.16.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareConstraintDn

1.3.6.1.4.1.9.9.826.2.1.30.16.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Constraint:dn managed object property

cfprApFirmwareConstraintRn

1.3.6.1.4.1.9.9.826.2.1.30.16.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Constraint:rn managed object property

cfprApFirmwareConstraintFeature

1.3.6.1.4.1.9.9.826.2.1.30.16.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Constraint:feature managed object property

cfprApFirmwareConstraintMinBiosVersion

1.3.6.1.4.1.9.9.826.2.1.30.16.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Constraint:minBiosVersion managed object property

cfprApFirmwareConstraintMinCimcVersion

1.3.6.1.4.1.9.9.826.2.1.30.16.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Constraint:minCimcVersion managed object property

cfprApFirmwareConstraintsTable

1.3.6.1.4.1.9.9.826.2.1.30.17

Index: cfprApFirmwareConstraintsInstanceId

Cisco Firepower firmware:Constraints managed object table

cfprApFirmwareConstraintsInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.17.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareConstraintsDn

1.3.6.1.4.1.9.9.826.2.1.30.17.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Constraints:dn managed object property

cfprApFirmwareConstraintsRn

1.3.6.1.4.1.9.9.826.2.1.30.17.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Constraints:rn managed object property

cfprApFirmwareCspAppListTable

1.3.6.1.4.1.9.9.826.2.1.30.18

Index: cfprApFirmwareCspAppListInstanceId

Cisco Firepower firmware:CspAppList managed object table

cfprApFirmwareCspAppListInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.18.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareCspAppListDn

1.3.6.1.4.1.9.9.826.2.1.30.18.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:CspAppList:dn managed object property

cfprApFirmwareCspAppListRn

1.3.6.1.4.1.9.9.826.2.1.30.18.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspAppList:rn managed object property

cfprApFirmwareCspAppListName

1.3.6.1.4.1.9.9.826.2.1.30.18.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspAppList:name managed object property

cfprApFirmwareCspVersionTable

1.3.6.1.4.1.9.9.826.2.1.30.19

Index: cfprApFirmwareCspVersionInstanceId

Cisco Firepower firmware:CspVersion managed object table

cfprApFirmwareCspVersionInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.19.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareCspVersionDn

1.3.6.1.4.1.9.9.826.2.1.30.19.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:CspVersion:dn managed object property

cfprApFirmwareCspVersionRn

1.3.6.1.4.1.9.9.826.2.1.30.19.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspVersion:rn managed object property

cfprApFirmwareCspVersionAppName

1.3.6.1.4.1.9.9.826.2.1.30.19.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspVersion:appName managed object property

cfprApFirmwareCspVersionFromVersion

1.3.6.1.4.1.9.9.826.2.1.30.19.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspVersion:fromVersion managed object property

cfprApFirmwareCspVersionName

1.3.6.1.4.1.9.9.826.2.1.30.19.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspVersion:name managed object property

cfprApFirmwareCspVersionToVersion

1.3.6.1.4.1.9.9.826.2.1.30.19.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:CspVersion:toVersion managed object property

cfprApFirmwareDependencyTable

1.3.6.1.4.1.9.9.826.2.1.30.20

Index: cfprApFirmwareDependencyInstanceId

Cisco Firepower firmware:Dependency managed object table

cfprApFirmwareDependencyInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.20.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDependencyDn

1.3.6.1.4.1.9.9.826.2.1.30.20.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Dependency:dn managed object property

cfprApFirmwareDependencyRn

1.3.6.1.4.1.9.9.826.2.1.30.20.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:rn managed object property

cfprApFirmwareDependencyEp

1.3.6.1.4.1.9.9.826.2.1.30.20.1.4

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:Dependency:ep managed object property

cfprApFirmwareDependencyHwModel

1.3.6.1.4.1.9.9.826.2.1.30.20.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:hwModel managed object property

cfprApFirmwareDependencyHwRevision

1.3.6.1.4.1.9.9.826.2.1.30.20.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:hwRevision managed object property

cfprApFirmwareDependencyHwVendor

1.3.6.1.4.1.9.9.826.2.1.30.20.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:hwVendor managed object property

cfprApFirmwareDependencyInvTag

1.3.6.1.4.1.9.9.826.2.1.30.20.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:invTag managed object property

cfprApFirmwareDependencyMaxVer

1.3.6.1.4.1.9.9.826.2.1.30.20.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:maxVer managed object property

cfprApFirmwareDependencyMinVer

1.3.6.1.4.1.9.9.826.2.1.30.20.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Dependency:minVer managed object property

cfprApFirmwareDependencyRelationship

1.3.6.1.4.1.9.9.826.2.1.30.20.1.11

CfprApFirmwareDependencyRelationship0 = special1 = ancestor2 = descendent · Integer32

Cisco Firepower firmware:Dependency:relationship managed object property

cfprApFirmwareDependencyScope

1.3.6.1.4.1.9.9.826.2.1.30.20.1.12

CfprApFirmwareDependencyScope0 = unknown1 = blade2 = chassis4 = system8 = switch16 = global · Integer32

Cisco Firepower firmware:Dependency:scope managed object property

cfprApFirmwareDependencySensitivity

1.3.6.1.4.1.9.9.826.2.1.30.20.1.13

CfprApFirmwareDependencySensitivity0 = global1 = fabric2 = path · Integer32

Cisco Firepower firmware:Dependency:sensitivity managed object property

cfprApFirmwareDistCspBlackListTable

1.3.6.1.4.1.9.9.826.2.1.30.21

Index: cfprApFirmwareDistCspBlackListInstanceId

Cisco Firepower firmware:DistCspBlackList managed object table

cfprApFirmwareDistCspBlackListInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.21.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDistCspBlackListDn

1.3.6.1.4.1.9.9.826.2.1.30.21.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DistCspBlackList:dn managed object property

cfprApFirmwareDistCspBlackListRn

1.3.6.1.4.1.9.9.826.2.1.30.21.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistCspBlackList:rn managed object property

cfprApFirmwareDistCspBlackListName

1.3.6.1.4.1.9.9.826.2.1.30.21.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistCspBlackList:name managed object property

cfprApFirmwareDistCspBlackListTimeStamp

1.3.6.1.4.1.9.9.826.2.1.30.21.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:DistCspBlackList:timeStamp managed object property

cfprApFirmwareDistCspBlackListVersion

1.3.6.1.4.1.9.9.826.2.1.30.21.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistCspBlackList:version managed object property

cfprApFirmwareDistImageTable

1.3.6.1.4.1.9.9.826.2.1.30.22

Index: cfprApFirmwareDistImageInstanceId

Cisco Firepower firmware:DistImage managed object table

cfprApFirmwareDistImageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.22.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDistImageDn

1.3.6.1.4.1.9.9.826.2.1.30.22.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DistImage:dn managed object property

cfprApFirmwareDistImageRn

1.3.6.1.4.1.9.9.826.2.1.30.22.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistImage:rn managed object property

cfprApFirmwareDistImageImageDeleted

1.3.6.1.4.1.9.9.826.2.1.30.22.1.4

CfprApFirmwareImageDeleted · BITS

Cisco Firepower firmware:DistImage:imageDeleted managed object property

cfprApFirmwareDistImageName

1.3.6.1.4.1.9.9.826.2.1.30.22.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistImage:name managed object property

cfprApFirmwareDistImageType

1.3.6.1.4.1.9.9.826.2.1.30.22.1.6

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:DistImage:type managed object property

cfprApFirmwareDistributableTable

1.3.6.1.4.1.9.9.826.2.1.30.23

Index: cfprApFirmwareDistributableInstanceId

Cisco Firepower firmware:Distributable managed object table

cfprApFirmwareDistributableInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.23.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDistributableDn

1.3.6.1.4.1.9.9.826.2.1.30.23.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Distributable:dn managed object property

cfprApFirmwareDistributableRn

1.3.6.1.4.1.9.9.826.2.1.30.23.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:rn managed object property

cfprApFirmwareDistributableAdminState

1.3.6.1.4.1.9.9.826.2.1.30.23.1.4

CfprApFirmwareAdminState0 = active1 = deleted · Integer32

Cisco Firepower firmware:Distributable:adminState managed object property

cfprApFirmwareDistributableBuildDate

1.3.6.1.4.1.9.9.826.2.1.30.23.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:buildDate managed object property

cfprApFirmwareDistributableCompleteness

1.3.6.1.4.1.9.9.826.2.1.30.23.1.6

CfprApFirmwareCompleteness0 = partial1 = complete · Integer32

Cisco Firepower firmware:Distributable:completeness managed object property

cfprApFirmwareDistributableDescr

1.3.6.1.4.1.9.9.826.2.1.30.23.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:descr managed object property

cfprApFirmwareDistributableDisplayFlag

1.3.6.1.4.1.9.9.826.2.1.30.23.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Distributable:displayFlag managed object property

cfprApFirmwareDistributableFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.23.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:fsmDescr managed object property

cfprApFirmwareDistributableFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.23.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:fsmPrev managed object property

cfprApFirmwareDistributableFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.23.1.11

Gauge32

Cisco Firepower firmware:Distributable:fsmProgr managed object property

cfprApFirmwareDistributableFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.23.1.12

Gauge32

Cisco Firepower firmware:Distributable:fsmRmtInvErrCode managed object property

cfprApFirmwareDistributableFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.23.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:fsmRmtInvErrDescr managed object property

cfprApFirmwareDistributableFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.23.1.14

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:Distributable:fsmRmtInvRslt managed object property

cfprApFirmwareDistributableFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.23.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:fsmStageDescr managed object property

cfprApFirmwareDistributableFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.23.1.16

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Distributable:fsmStamp managed object property

cfprApFirmwareDistributableFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.23.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:fsmStatus managed object property

cfprApFirmwareDistributableFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.23.1.18

Gauge32

Cisco Firepower firmware:Distributable:fsmTry managed object property

cfprApFirmwareDistributableImagePresence

1.3.6.1.4.1.9.9.826.2.1.30.23.1.19

CfprApFirmwareImagePresence · BITS

Cisco Firepower firmware:Distributable:imagePresence managed object property

cfprApFirmwareDistributableIntId

1.3.6.1.4.1.9.9.826.2.1.30.23.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:intId managed object property

cfprApFirmwareDistributableInvTag

1.3.6.1.4.1.9.9.826.2.1.30.23.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:invTag managed object property

cfprApFirmwareDistributableModel

1.3.6.1.4.1.9.9.826.2.1.30.23.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:model managed object property

cfprApFirmwareDistributableName

1.3.6.1.4.1.9.9.826.2.1.30.23.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:name managed object property

cfprApFirmwareDistributablePlatformVersion

1.3.6.1.4.1.9.9.826.2.1.30.23.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:platformVersion managed object property

cfprApFirmwareDistributablePolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.23.1.25

Gauge32

Cisco Firepower firmware:Distributable:policyLevel managed object property

cfprApFirmwareDistributablePolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.23.1.26

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:Distributable:policyOwner managed object property

cfprApFirmwareDistributableTimeStamp

1.3.6.1.4.1.9.9.826.2.1.30.23.1.27

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Distributable:timeStamp managed object property

cfprApFirmwareDistributableTransferState

1.3.6.1.4.1.9.9.826.2.1.30.23.1.28

CfprApFirmwareTransferState0 = init1 = downloading2 = downloaded3 = failed · Integer32

Cisco Firepower firmware:Distributable:transferState managed object property

cfprApFirmwareDistributableType

1.3.6.1.4.1.9.9.826.2.1.30.23.1.29

CfprApFirmwareDistributableType0 = unknown1 = image2 = fullBundle3 = infrastructureBundle4 = bSeriesBundle5 = cSeriesBundle6 = catalog7 = platformBundle8 = firmwareFpr9kBundle9 = firmwareFpr4kBundle10 = appBundle · Integer32

Cisco Firepower firmware:Distributable:type managed object property

cfprApFirmwareDistributableVendor

1.3.6.1.4.1.9.9.826.2.1.30.23.1.30

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:vendor managed object property

cfprApFirmwareDistributableVersion

1.3.6.1.4.1.9.9.826.2.1.30.23.1.31

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Distributable:version managed object property

cfprApFirmwareDistributableFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.24

Index: cfprApFirmwareDistributableFsmInstanceId

Cisco Firepower firmware:DistributableFsm managed object table

cfprApFirmwareDistributableFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.24.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDistributableFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.24.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DistributableFsm:dn managed object property

cfprApFirmwareDistributableFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.24.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistributableFsm:rn managed object property

cfprApFirmwareDistributableFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.24.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:DistributableFsm:completionTime managed object property

cfprApFirmwareDistributableFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.24.1.5

CfprApFirmwareDistributableFsmCurrentFsm0 = nop14 = delete · Integer32

Cisco Firepower firmware:DistributableFsm:currentFsm managed object property

cfprApFirmwareDistributableFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.24.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistributableFsm:descr managed object property

cfprApFirmwareDistributableFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.24.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:DistributableFsm:fsmStatus managed object property

cfprApFirmwareDistributableFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.24.1.8

Gauge32

Cisco Firepower firmware:DistributableFsm:progress managed object property

cfprApFirmwareDistributableFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.24.1.9

Gauge32

Cisco Firepower firmware:DistributableFsm:rmtErrCode managed object property

cfprApFirmwareDistributableFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.24.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistributableFsm:rmtErrDescr managed object property

cfprApFirmwareDistributableFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.24.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:DistributableFsm:rmtRslt managed object property

cfprApFirmwareDistributableFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.25

Index: cfprApFirmwareDistributableFsmStageInstanceId

Cisco Firepower firmware:DistributableFsmStage managed object table

cfprApFirmwareDistributableFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.25.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDistributableFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.25.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DistributableFsmStage:dn managed object property

cfprApFirmwareDistributableFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.25.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistributableFsmStage:rn managed object property

cfprApFirmwareDistributableFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.25.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistributableFsmStage:descr managed object property

cfprApFirmwareDistributableFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.25.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:DistributableFsmStage:lastUpdateTime managed object property

cfprApFirmwareDistributableFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.25.1.6

CfprApFirmwareDistributableFsmStageName0 = nop14 = deleteBegin15 = deleteLocal16 = deleteRemote612 = deleteFail613 = deleteSuccess · Integer32

Cisco Firepower firmware:DistributableFsmStage:name managed object property

cfprApFirmwareDistributableFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.25.1.7

Gauge32

Cisco Firepower firmware:DistributableFsmStage:order managed object property

cfprApFirmwareDistributableFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.25.1.8

Gauge32

Cisco Firepower firmware:DistributableFsmStage:retry managed object property

cfprApFirmwareDistributableFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.25.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:DistributableFsmStage:stageStatus managed object property

cfprApFirmwareDistributableFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.26

Index: cfprApFirmwareDistributableFsmTaskInstanceId

Cisco Firepower firmware:DistributableFsmTask managed object table

cfprApFirmwareDistributableFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.26.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDistributableFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.26.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DistributableFsmTask:dn managed object property

cfprApFirmwareDistributableFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.26.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DistributableFsmTask:rn managed object property

cfprApFirmwareDistributableFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.26.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:DistributableFsmTask:completion managed object property

cfprApFirmwareDistributableFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.26.1.5

CfprApFsmFlags · BITS

Cisco Firepower firmware:DistributableFsmTask:flags managed object property

cfprApFirmwareDistributableFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.26.1.6

CfprApFirmwareDistributableFsmTaskItem0 = nop14 = delete · Integer32

Cisco Firepower firmware:DistributableFsmTask:item managed object property

cfprApFirmwareDistributableFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.26.1.7

Gauge32

Cisco Firepower firmware:DistributableFsmTask:seqId managed object property

cfprApFirmwareDownloaderTable

1.3.6.1.4.1.9.9.826.2.1.30.27

Index: cfprApFirmwareDownloaderInstanceId

Cisco Firepower firmware:Downloader managed object table

cfprApFirmwareDownloaderInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.27.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDownloaderDn

1.3.6.1.4.1.9.9.826.2.1.30.27.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Downloader:dn managed object property

cfprApFirmwareDownloaderRn

1.3.6.1.4.1.9.9.826.2.1.30.27.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:rn managed object property

cfprApFirmwareDownloaderAdminState

1.3.6.1.4.1.9.9.826.2.1.30.27.1.4

CfprApFirmwareDownloadActivity0 = restart1 = idle · Integer32

Cisco Firepower firmware:Downloader:adminState managed object property

cfprApFirmwareDownloaderFileName

1.3.6.1.4.1.9.9.826.2.1.30.27.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:fileName managed object property

cfprApFirmwareDownloaderFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.27.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:fsmDescr managed object property

cfprApFirmwareDownloaderFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.27.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:fsmPrev managed object property

cfprApFirmwareDownloaderFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.27.1.8

Gauge32

Cisco Firepower firmware:Downloader:fsmProgr managed object property

cfprApFirmwareDownloaderFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.27.1.9

Gauge32

Cisco Firepower firmware:Downloader:fsmRmtInvErrCode managed object property

cfprApFirmwareDownloaderFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.27.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:fsmRmtInvErrDescr managed object property

cfprApFirmwareDownloaderFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.27.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:Downloader:fsmRmtInvRslt managed object property

cfprApFirmwareDownloaderFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.27.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:fsmStageDescr managed object property

cfprApFirmwareDownloaderFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.27.1.13

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Downloader:fsmStamp managed object property

cfprApFirmwareDownloaderFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.27.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:fsmStatus managed object property

cfprApFirmwareDownloaderFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.27.1.15

Gauge32

Cisco Firepower firmware:Downloader:fsmTry managed object property

cfprApFirmwareDownloaderImageSize

1.3.6.1.4.1.9.9.826.2.1.30.27.1.16

Gauge32

Cisco Firepower firmware:Downloader:imageSize managed object property

cfprApFirmwareDownloaderPort

1.3.6.1.4.1.9.9.826.2.1.30.27.1.17

Gauge32

Cisco Firepower firmware:Downloader:port managed object property

cfprApFirmwareDownloaderProtocol

1.3.6.1.4.1.9.9.826.2.1.30.27.1.18

CfprApFirmwareTransport0 = ftp1 = tftp2 = scp3 = sftp4 = local5 = usbA6 = usbB · Integer32

Cisco Firepower firmware:Downloader:protocol managed object property

cfprApFirmwareDownloaderPwd

1.3.6.1.4.1.9.9.826.2.1.30.27.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:pwd managed object property

cfprApFirmwareDownloaderRemotePath

1.3.6.1.4.1.9.9.826.2.1.30.27.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:remotePath managed object property

cfprApFirmwareDownloaderServer

1.3.6.1.4.1.9.9.826.2.1.30.27.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:server managed object property

cfprApFirmwareDownloaderStartTime

1.3.6.1.4.1.9.9.826.2.1.30.27.1.22

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Downloader:startTime managed object property

cfprApFirmwareDownloaderTimeStamp

1.3.6.1.4.1.9.9.826.2.1.30.27.1.23

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Downloader:timeStamp managed object property

cfprApFirmwareDownloaderTransferRate

1.3.6.1.4.1.9.9.826.2.1.30.27.1.24

INTEGER · Integer32

Cisco Firepower firmware:Downloader:transferRate managed object property

cfprApFirmwareDownloaderTransferState

1.3.6.1.4.1.9.9.826.2.1.30.27.1.25

CfprApFirmwareTransferState0 = init1 = downloading2 = downloaded3 = failed · Integer32

Cisco Firepower firmware:Downloader:transferState managed object property

cfprApFirmwareDownloaderUser

1.3.6.1.4.1.9.9.826.2.1.30.27.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Downloader:user managed object property

cfprApFirmwareDownloaderFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.28

Index: cfprApFirmwareDownloaderFsmInstanceId

Cisco Firepower firmware:DownloaderFsm managed object table

cfprApFirmwareDownloaderFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.28.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDownloaderFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.28.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DownloaderFsm:dn managed object property

cfprApFirmwareDownloaderFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.28.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DownloaderFsm:rn managed object property

cfprApFirmwareDownloaderFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.28.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:DownloaderFsm:completionTime managed object property

cfprApFirmwareDownloaderFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.28.1.5

CfprApFirmwareDownloaderFsmCurrentFsm0 = nop6 = download · Integer32

Cisco Firepower firmware:DownloaderFsm:currentFsm managed object property

cfprApFirmwareDownloaderFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.28.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DownloaderFsm:descr managed object property

cfprApFirmwareDownloaderFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.28.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:DownloaderFsm:fsmStatus managed object property

cfprApFirmwareDownloaderFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.28.1.8

Gauge32

Cisco Firepower firmware:DownloaderFsm:progress managed object property

cfprApFirmwareDownloaderFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.28.1.9

Gauge32

Cisco Firepower firmware:DownloaderFsm:rmtErrCode managed object property

cfprApFirmwareDownloaderFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.28.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DownloaderFsm:rmtErrDescr managed object property

cfprApFirmwareDownloaderFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.28.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:DownloaderFsm:rmtRslt managed object property

cfprApFirmwareDownloaderFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.29

Index: cfprApFirmwareDownloaderFsmStageInstanceId

Cisco Firepower firmware:DownloaderFsmStage managed object table

cfprApFirmwareDownloaderFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.29.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDownloaderFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.29.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DownloaderFsmStage:dn managed object property

cfprApFirmwareDownloaderFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.29.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DownloaderFsmStage:rn managed object property

cfprApFirmwareDownloaderFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.29.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DownloaderFsmStage:descr managed object property

cfprApFirmwareDownloaderFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.29.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:DownloaderFsmStage:lastUpdateTime managed object property

cfprApFirmwareDownloaderFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.29.1.6

CfprApFirmwareDownloaderFsmStageName0 = nop6 = downloadBegin7 = downloadLocal8 = downloadUnpackLocal9 = downloadDeleteLocal10 = downloadCopyRemote614 = downloadFail615 = downloadSuccess · Integer32

Cisco Firepower firmware:DownloaderFsmStage:name managed object property

cfprApFirmwareDownloaderFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.29.1.7

Gauge32

Cisco Firepower firmware:DownloaderFsmStage:order managed object property

cfprApFirmwareDownloaderFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.29.1.8

Gauge32

Cisco Firepower firmware:DownloaderFsmStage:retry managed object property

cfprApFirmwareDownloaderFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.29.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:DownloaderFsmStage:stageStatus managed object property

cfprApFirmwareDownloaderFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.30

Index: cfprApFirmwareDownloaderFsmTaskInstanceId

Cisco Firepower firmware:DownloaderFsmTask managed object table

cfprApFirmwareDownloaderFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.30.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareDownloaderFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.30.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:DownloaderFsmTask:dn managed object property

cfprApFirmwareDownloaderFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.30.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:DownloaderFsmTask:rn managed object property

cfprApFirmwareDownloaderFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.30.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:DownloaderFsmTask:completion managed object property

cfprApFirmwareDownloaderFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.30.1.5

CfprApFsmFlags · BITS

Cisco Firepower firmware:DownloaderFsmTask:flags managed object property

cfprApFirmwareDownloaderFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.30.1.6

CfprApFirmwareDownloaderFsmTaskItem0 = nop6 = download · Integer32

Cisco Firepower firmware:DownloaderFsmTask:item managed object property

cfprApFirmwareDownloaderFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.30.1.7

Gauge32

Cisco Firepower firmware:DownloaderFsmTask:seqId managed object property

cfprApFirmwareHostTable

1.3.6.1.4.1.9.9.826.2.1.30.31

Index: cfprApFirmwareHostInstanceId

Cisco Firepower firmware:Host managed object table

cfprApFirmwareHostInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.31.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareHostDn

1.3.6.1.4.1.9.9.826.2.1.30.31.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Host:dn managed object property

cfprApFirmwareHostRn

1.3.6.1.4.1.9.9.826.2.1.30.31.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Host:rn managed object property

cfprApFirmwareHostPackModImpactTable

1.3.6.1.4.1.9.9.826.2.1.30.32

Index: cfprApFirmwareHostPackModImpactInstanceId

Cisco Firepower firmware:HostPackModImpact managed object table

cfprApFirmwareHostPackModImpactInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.32.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareHostPackModImpactDn

1.3.6.1.4.1.9.9.826.2.1.30.32.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:HostPackModImpact:dn managed object property

cfprApFirmwareHostPackModImpactRn

1.3.6.1.4.1.9.9.826.2.1.30.32.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:HostPackModImpact:rn managed object property

cfprApFirmwareHostPackModImpactKeyDn

1.3.6.1.4.1.9.9.826.2.1.30.32.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:HostPackModImpact:keyDn managed object property

cfprApFirmwareHostPackModImpactMaintPolicyDn

1.3.6.1.4.1.9.9.826.2.1.30.32.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:HostPackModImpact:maintPolicyDn managed object property

cfprApFirmwareHostPackModImpactPnDn

1.3.6.1.4.1.9.9.826.2.1.30.32.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:HostPackModImpact:pnDn managed object property

cfprApFirmwareHostPackModImpactRebootPolicy

1.3.6.1.4.1.9.9.826.2.1.30.32.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:HostPackModImpact:rebootPolicy managed object property

cfprApFirmwareHostPackModImpactServiceProfileDn

1.3.6.1.4.1.9.9.826.2.1.30.32.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:HostPackModImpact:serviceProfileDn managed object property

cfprApFirmwareImageTable

1.3.6.1.4.1.9.9.826.2.1.30.33

Index: cfprApFirmwareImageInstanceId

Cisco Firepower firmware:Image managed object table

cfprApFirmwareImageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.33.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareImageDn

1.3.6.1.4.1.9.9.826.2.1.30.33.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Image:dn managed object property

cfprApFirmwareImageRn

1.3.6.1.4.1.9.9.826.2.1.30.33.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:rn managed object property

cfprApFirmwareImageAdminState

1.3.6.1.4.1.9.9.826.2.1.30.33.1.4

CfprApFirmwareAdminState0 = active1 = deleted · Integer32

Cisco Firepower firmware:Image:adminState managed object property

cfprApFirmwareImageChecksum

1.3.6.1.4.1.9.9.826.2.1.30.33.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:checksum managed object property

cfprApFirmwareImageDescr

1.3.6.1.4.1.9.9.826.2.1.30.33.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:descr managed object property

cfprApFirmwareImageDownloadDate

1.3.6.1.4.1.9.9.826.2.1.30.33.1.7

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Image:downloadDate managed object property

cfprApFirmwareImageFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.33.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:fsmDescr managed object property

cfprApFirmwareImageFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.33.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:fsmPrev managed object property

cfprApFirmwareImageFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.33.1.10

Gauge32

Cisco Firepower firmware:Image:fsmProgr managed object property

cfprApFirmwareImageFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.33.1.11

Gauge32

Cisco Firepower firmware:Image:fsmRmtInvErrCode managed object property

cfprApFirmwareImageFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.33.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:fsmRmtInvErrDescr managed object property

cfprApFirmwareImageFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.33.1.13

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:Image:fsmRmtInvRslt managed object property

cfprApFirmwareImageFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.33.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:fsmStageDescr managed object property

cfprApFirmwareImageFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.33.1.15

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Image:fsmStamp managed object property

cfprApFirmwareImageFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.33.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:fsmStatus managed object property

cfprApFirmwareImageFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.33.1.17

Gauge32

Cisco Firepower firmware:Image:fsmTry managed object property

cfprApFirmwareImageImagePresence

1.3.6.1.4.1.9.9.826.2.1.30.33.1.18

CfprApFirmwareImagePresence · BITS

Cisco Firepower firmware:Image:imagePresence managed object property

cfprApFirmwareImageIntId

1.3.6.1.4.1.9.9.826.2.1.30.33.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:intId managed object property

cfprApFirmwareImageInvTag

1.3.6.1.4.1.9.9.826.2.1.30.33.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:invTag managed object property

cfprApFirmwareImageIsoname

1.3.6.1.4.1.9.9.826.2.1.30.33.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:isoname managed object property

cfprApFirmwareImageLocation

1.3.6.1.4.1.9.9.826.2.1.30.33.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:location managed object property

cfprApFirmwareImageName

1.3.6.1.4.1.9.9.826.2.1.30.33.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:name managed object property

cfprApFirmwareImagePolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.33.1.24

Gauge32

Cisco Firepower firmware:Image:policyLevel managed object property

cfprApFirmwareImagePolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.33.1.25

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:Image:policyOwner managed object property

cfprApFirmwareImageSize

1.3.6.1.4.1.9.9.826.2.1.30.33.1.26

Gauge32

Cisco Firepower firmware:Image:size managed object property

cfprApFirmwareImageType

1.3.6.1.4.1.9.9.826.2.1.30.33.1.27

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:Image:type managed object property

cfprApFirmwareImageVersion

1.3.6.1.4.1.9.9.826.2.1.30.33.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Image:version managed object property

cfprApFirmwareImageFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.34

Index: cfprApFirmwareImageFsmInstanceId

Cisco Firepower firmware:ImageFsm managed object table

cfprApFirmwareImageFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.34.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareImageFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.34.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:ImageFsm:dn managed object property

cfprApFirmwareImageFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.34.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageFsm:rn managed object property

cfprApFirmwareImageFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.34.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:ImageFsm:completionTime managed object property

cfprApFirmwareImageFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.34.1.5

CfprApFirmwareImageFsmCurrentFsm0 = nop11 = delete · Integer32

Cisco Firepower firmware:ImageFsm:currentFsm managed object property

cfprApFirmwareImageFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.34.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageFsm:descr managed object property

cfprApFirmwareImageFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.34.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:ImageFsm:fsmStatus managed object property

cfprApFirmwareImageFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.34.1.8

Gauge32

Cisco Firepower firmware:ImageFsm:progress managed object property

cfprApFirmwareImageFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.34.1.9

Gauge32

Cisco Firepower firmware:ImageFsm:rmtErrCode managed object property

cfprApFirmwareImageFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.34.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageFsm:rmtErrDescr managed object property

cfprApFirmwareImageFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.34.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:ImageFsm:rmtRslt managed object property

cfprApFirmwareImageFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.35

Index: cfprApFirmwareImageFsmStageInstanceId

Cisco Firepower firmware:ImageFsmStage managed object table

cfprApFirmwareImageFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.35.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareImageFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.35.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:ImageFsmStage:dn managed object property

cfprApFirmwareImageFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.35.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageFsmStage:rn managed object property

cfprApFirmwareImageFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.35.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageFsmStage:descr managed object property

cfprApFirmwareImageFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.35.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:ImageFsmStage:lastUpdateTime managed object property

cfprApFirmwareImageFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.35.1.6

CfprApFirmwareImageFsmStageName0 = nop11 = deleteBegin12 = deleteLocal13 = deleteRemote616 = deleteFail617 = deleteSuccess · Integer32

Cisco Firepower firmware:ImageFsmStage:name managed object property

cfprApFirmwareImageFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.35.1.7

Gauge32

Cisco Firepower firmware:ImageFsmStage:order managed object property

cfprApFirmwareImageFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.35.1.8

Gauge32

Cisco Firepower firmware:ImageFsmStage:retry managed object property

cfprApFirmwareImageFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.35.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:ImageFsmStage:stageStatus managed object property

cfprApFirmwareImageFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.36

Index: cfprApFirmwareImageFsmTaskInstanceId

Cisco Firepower firmware:ImageFsmTask managed object table

cfprApFirmwareImageFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.36.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareImageFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.36.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:ImageFsmTask:dn managed object property

cfprApFirmwareImageFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.36.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageFsmTask:rn managed object property

cfprApFirmwareImageFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.36.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:ImageFsmTask:completion managed object property

cfprApFirmwareImageFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.36.1.5

CfprApFsmFlags · BITS

Cisco Firepower firmware:ImageFsmTask:flags managed object property

cfprApFirmwareImageFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.36.1.6

CfprApFirmwareImageFsmTaskItem0 = nop11 = delete · Integer32

Cisco Firepower firmware:ImageFsmTask:item managed object property

cfprApFirmwareImageFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.36.1.7

Gauge32

Cisco Firepower firmware:ImageFsmTask:seqId managed object property

cfprApFirmwareImageLockTable

1.3.6.1.4.1.9.9.826.2.1.30.37

Index: cfprApFirmwareImageLockInstanceId

Cisco Firepower firmware:ImageLock managed object table

cfprApFirmwareImageLockInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.37.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareImageLockDn

1.3.6.1.4.1.9.9.826.2.1.30.37.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:ImageLock:dn managed object property

cfprApFirmwareImageLockRn

1.3.6.1.4.1.9.9.826.2.1.30.37.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageLock:rn managed object property

cfprApFirmwareImageLockImageNameDn

1.3.6.1.4.1.9.9.826.2.1.30.37.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageLock:ImageNameDn managed object property

cfprApFirmwareImageLockName

1.3.6.1.4.1.9.9.826.2.1.30.37.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:ImageLock:name managed object property

cfprApFirmwareInfraTable

1.3.6.1.4.1.9.9.826.2.1.30.38

Index: cfprApFirmwareInfraInstanceId

Cisco Firepower firmware:Infra managed object table

cfprApFirmwareInfraInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.38.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInfraDn

1.3.6.1.4.1.9.9.826.2.1.30.38.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Infra:dn managed object property

cfprApFirmwareInfraRn

1.3.6.1.4.1.9.9.826.2.1.30.38.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:rn managed object property

cfprApFirmwareInfraAdminState

1.3.6.1.4.1.9.9.826.2.1.30.38.1.4

CfprApTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower firmware:Infra:adminState managed object property

cfprApFirmwareInfraAutoDelete

1.3.6.1.4.1.9.9.826.2.1.30.38.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Infra:autoDelete managed object property

cfprApFirmwareInfraDescr

1.3.6.1.4.1.9.9.826.2.1.30.38.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:descr managed object property

cfprApFirmwareInfraIgnoreCap

1.3.6.1.4.1.9.9.826.2.1.30.38.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Infra:ignoreCap managed object property

cfprApFirmwareInfraIntId

1.3.6.1.4.1.9.9.826.2.1.30.38.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:intId managed object property

cfprApFirmwareInfraName

1.3.6.1.4.1.9.9.826.2.1.30.38.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:name managed object property

cfprApFirmwareInfraOperScheduler

1.3.6.1.4.1.9.9.826.2.1.30.38.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:operScheduler managed object property

cfprApFirmwareInfraOperState

1.3.6.1.4.1.9.9.826.2.1.30.38.1.11

CfprApTrigTrigOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower firmware:Infra:operState managed object property

cfprApFirmwareInfraOperVersion

1.3.6.1.4.1.9.9.826.2.1.30.38.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:operVersion managed object property

cfprApFirmwareInfraPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.38.1.13

Gauge32

Cisco Firepower firmware:Infra:policyLevel managed object property

cfprApFirmwareInfraPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.38.1.14

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:Infra:policyOwner managed object property

cfprApFirmwareInfraScheduler

1.3.6.1.4.1.9.9.826.2.1.30.38.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Infra:scheduler managed object property

cfprApFirmwareInfraPackTable

1.3.6.1.4.1.9.9.826.2.1.30.39

Index: cfprApFirmwareInfraPackInstanceId

Cisco Firepower firmware:InfraPack managed object table

cfprApFirmwareInfraPackInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.39.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInfraPackDn

1.3.6.1.4.1.9.9.826.2.1.30.39.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:InfraPack:dn managed object property

cfprApFirmwareInfraPackRn

1.3.6.1.4.1.9.9.826.2.1.30.39.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:rn managed object property

cfprApFirmwareInfraPackDescr

1.3.6.1.4.1.9.9.826.2.1.30.39.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:descr managed object property

cfprApFirmwareInfraPackForceDeploy

1.3.6.1.4.1.9.9.826.2.1.30.39.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:InfraPack:forceDeploy managed object property

cfprApFirmwareInfraPackFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.39.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:fsmDescr managed object property

cfprApFirmwareInfraPackFsmFlags

1.3.6.1.4.1.9.9.826.2.1.30.39.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:fsmFlags managed object property

cfprApFirmwareInfraPackFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.39.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:fsmPrev managed object property

cfprApFirmwareInfraPackFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.39.1.9

Gauge32

Cisco Firepower firmware:InfraPack:fsmProgr managed object property

cfprApFirmwareInfraPackFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.39.1.10

Gauge32

Cisco Firepower firmware:InfraPack:fsmRmtInvErrCode managed object property

cfprApFirmwareInfraPackFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.39.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:fsmRmtInvErrDescr managed object property

cfprApFirmwareInfraPackFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.39.1.12

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:InfraPack:fsmRmtInvRslt managed object property

cfprApFirmwareInfraPackFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.39.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:fsmStageDescr managed object property

cfprApFirmwareInfraPackFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.39.1.14

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:InfraPack:fsmStamp managed object property

cfprApFirmwareInfraPackFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.39.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:fsmStatus managed object property

cfprApFirmwareInfraPackFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.39.1.16

Gauge32

Cisco Firepower firmware:InfraPack:fsmTry managed object property

cfprApFirmwareInfraPackInfraBundleName

1.3.6.1.4.1.9.9.826.2.1.30.39.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:infraBundleName managed object property

cfprApFirmwareInfraPackInfraBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.39.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:infraBundleVersion managed object property

cfprApFirmwareInfraPackIntId

1.3.6.1.4.1.9.9.826.2.1.30.39.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:intId managed object property

cfprApFirmwareInfraPackMode

1.3.6.1.4.1.9.9.826.2.1.30.39.1.20

CfprApFirmwarePackMode0 = staged1 = oneShot · Integer32

Cisco Firepower firmware:InfraPack:mode managed object property

cfprApFirmwareInfraPackName

1.3.6.1.4.1.9.9.826.2.1.30.39.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:name managed object property

cfprApFirmwareInfraPackPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.39.1.22

Gauge32

Cisco Firepower firmware:InfraPack:policyLevel managed object property

cfprApFirmwareInfraPackPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.39.1.23

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:InfraPack:policyOwner managed object property

cfprApFirmwareInfraPackPreviousBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.39.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPack:previousBundleVersion managed object property

cfprApFirmwareInfraPackStageSize

1.3.6.1.4.1.9.9.826.2.1.30.39.1.25

Gauge32

Cisco Firepower firmware:InfraPack:stageSize managed object property

cfprApFirmwareInfraPackUpdateTrigger

1.3.6.1.4.1.9.9.826.2.1.30.39.1.26

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:InfraPack:updateTrigger managed object property

cfprApFirmwareInfraPackFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.40

Index: cfprApFirmwareInfraPackFsmInstanceId

Cisco Firepower firmware:InfraPackFsm managed object table

cfprApFirmwareInfraPackFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.40.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInfraPackFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.40.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:InfraPackFsm:dn managed object property

cfprApFirmwareInfraPackFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.40.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPackFsm:rn managed object property

cfprApFirmwareInfraPackFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.40.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:InfraPackFsm:completionTime managed object property

cfprApFirmwareInfraPackFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.40.1.5

CfprApFirmwareInfraPackFsmCurrentFsm0 = nop828 = infraVersion · Integer32

Cisco Firepower firmware:InfraPackFsm:currentFsm managed object property

cfprApFirmwareInfraPackFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.40.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPackFsm:descr managed object property

cfprApFirmwareInfraPackFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.40.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:InfraPackFsm:fsmStatus managed object property

cfprApFirmwareInfraPackFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.40.1.8

Gauge32

Cisco Firepower firmware:InfraPackFsm:progress managed object property

cfprApFirmwareInfraPackFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.40.1.9

Gauge32

Cisco Firepower firmware:InfraPackFsm:rmtErrCode managed object property

cfprApFirmwareInfraPackFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.40.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPackFsm:rmtErrDescr managed object property

cfprApFirmwareInfraPackFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.40.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:InfraPackFsm:rmtRslt managed object property

cfprApFirmwareInfraPackFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.41

Index: cfprApFirmwareInfraPackFsmStageInstanceId

Cisco Firepower firmware:InfraPackFsmStage managed object table

cfprApFirmwareInfraPackFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.41.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInfraPackFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.41.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:InfraPackFsmStage:dn managed object property

cfprApFirmwareInfraPackFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.41.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPackFsmStage:rn managed object property

cfprApFirmwareInfraPackFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.41.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPackFsmStage:descr managed object property

cfprApFirmwareInfraPackFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.41.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:InfraPackFsmStage:lastUpdateTime managed object property

cfprApFirmwareInfraPackFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.41.1.6

CfprApFirmwareInfraPackFsmStageName0 = nop828 = infraVersionBegin829 = infraVersionWaitForReady830 = infraVersionRestore831 = infraVersionFail832 = infraVersionSuccess · Integer32

Cisco Firepower firmware:InfraPackFsmStage:name managed object property

cfprApFirmwareInfraPackFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.41.1.7

Gauge32

Cisco Firepower firmware:InfraPackFsmStage:order managed object property

cfprApFirmwareInfraPackFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.41.1.8

Gauge32

Cisco Firepower firmware:InfraPackFsmStage:retry managed object property

cfprApFirmwareInfraPackFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.41.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:InfraPackFsmStage:stageStatus managed object property

cfprApFirmwareInfraPackFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.42

Index: cfprApFirmwareInfraPackFsmTaskInstanceId

Cisco Firepower firmware:InfraPackFsmTask managed object table

cfprApFirmwareInfraPackFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.42.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInfraPackFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.42.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:InfraPackFsmTask:dn managed object property

cfprApFirmwareInfraPackFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.42.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InfraPackFsmTask:rn managed object property

cfprApFirmwareInfraPackFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.42.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:InfraPackFsmTask:completion managed object property

cfprApFirmwareInfraPackFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.42.1.5

CfprApFirmwareInfraPackFsmTaskFlags · BITS

Cisco Firepower firmware:InfraPackFsmTask:flags managed object property

cfprApFirmwareInfraPackFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.42.1.6

CfprApFirmwareInfraPackFsmTaskItem0 = nop828 = infraVersion · Integer32

Cisco Firepower firmware:InfraPackFsmTask:item managed object property

cfprApFirmwareInfraPackFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.42.1.7

Gauge32

Cisco Firepower firmware:InfraPackFsmTask:seqId managed object property

cfprApFirmwareInstallImpactTable

1.3.6.1.4.1.9.9.826.2.1.30.43

Index: cfprApFirmwareInstallImpactInstanceId

Cisco Firepower firmware:InstallImpact managed object table

cfprApFirmwareInstallImpactInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.43.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInstallImpactDn

1.3.6.1.4.1.9.9.826.2.1.30.43.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:InstallImpact:dn managed object property

cfprApFirmwareInstallImpactRn

1.3.6.1.4.1.9.9.826.2.1.30.43.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InstallImpact:rn managed object property

cfprApFirmwareInstallImpactDescr

1.3.6.1.4.1.9.9.826.2.1.30.43.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InstallImpact:descr managed object property

cfprApFirmwareInstallImpactKeyDn

1.3.6.1.4.1.9.9.826.2.1.30.43.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InstallImpact:keyDn managed object property

cfprApFirmwareInstallImpactMaintPolicyDn

1.3.6.1.4.1.9.9.826.2.1.30.43.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InstallImpact:maintPolicyDn managed object property

cfprApFirmwareInstallImpactRebootPolicy

1.3.6.1.4.1.9.9.826.2.1.30.43.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:InstallImpact:rebootPolicy managed object property

cfprApFirmwareInstallImpactSubject

1.3.6.1.4.1.9.9.826.2.1.30.43.1.8

CfprApFirmwareEquipmentType0 = unknown1 = system2 = switch3 = iocard4 = server5 = cimc6 = adaptor7 = storageController8 = boardController9 = bios10 = serviceProfile11 = graphicsCard · Integer32

Cisco Firepower firmware:InstallImpact:subject managed object property

cfprApFirmwareInstallImpactType

1.3.6.1.4.1.9.9.826.2.1.30.43.1.9

CfprApFirmwareImpactType0 = activate1 = noimpact2 = reset3 = update · Integer32

Cisco Firepower firmware:InstallImpact:type managed object property

cfprApFirmwareInstallableTable

1.3.6.1.4.1.9.9.826.2.1.30.44

Index: cfprApFirmwareInstallableInstanceId

Cisco Firepower firmware:Installable managed object table

cfprApFirmwareInstallableInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.44.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareInstallableDn

1.3.6.1.4.1.9.9.826.2.1.30.44.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Installable:dn managed object property

cfprApFirmwareInstallableRn

1.3.6.1.4.1.9.9.826.2.1.30.44.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:rn managed object property

cfprApFirmwareInstallableChecksum

1.3.6.1.4.1.9.9.826.2.1.30.44.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:checksum managed object property

cfprApFirmwareInstallableInProgress

1.3.6.1.4.1.9.9.826.2.1.30.44.1.5

Gauge32

Cisco Firepower firmware:Installable:inProgress managed object property

cfprApFirmwareInstallableIsoname

1.3.6.1.4.1.9.9.826.2.1.30.44.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:isoname managed object property

cfprApFirmwareInstallableLocation

1.3.6.1.4.1.9.9.826.2.1.30.44.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:location managed object property

cfprApFirmwareInstallableModel

1.3.6.1.4.1.9.9.826.2.1.30.44.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:model managed object property

cfprApFirmwareInstallableName

1.3.6.1.4.1.9.9.826.2.1.30.44.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:name managed object property

cfprApFirmwareInstallableSize

1.3.6.1.4.1.9.9.826.2.1.30.44.1.10

Gauge32

Cisco Firepower firmware:Installable:size managed object property

cfprApFirmwareInstallableType

1.3.6.1.4.1.9.9.826.2.1.30.44.1.11

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:Installable:type managed object property

cfprApFirmwareInstallableVendor

1.3.6.1.4.1.9.9.826.2.1.30.44.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:vendor managed object property

cfprApFirmwareInstallableVersion

1.3.6.1.4.1.9.9.826.2.1.30.44.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Installable:version managed object property

cfprApFirmwarePackItemTable

1.3.6.1.4.1.9.9.826.2.1.30.45

Index: cfprApFirmwarePackItemInstanceId

Cisco Firepower firmware:PackItem managed object table

cfprApFirmwarePackItemInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.45.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePackItemDn

1.3.6.1.4.1.9.9.826.2.1.30.45.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:PackItem:dn managed object property

cfprApFirmwarePackItemRn

1.3.6.1.4.1.9.9.826.2.1.30.45.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PackItem:rn managed object property

cfprApFirmwarePackItemHwModel

1.3.6.1.4.1.9.9.826.2.1.30.45.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PackItem:hwModel managed object property

cfprApFirmwarePackItemHwVendor

1.3.6.1.4.1.9.9.826.2.1.30.45.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PackItem:hwVendor managed object property

cfprApFirmwarePackItemPresence

1.3.6.1.4.1.9.9.826.2.1.30.45.1.6

CfprApFirmwarePackItemPresence0 = unknown1 = missing2 = present · Integer32

Cisco Firepower firmware:PackItem:presence managed object property

cfprApFirmwarePackItemType

1.3.6.1.4.1.9.9.826.2.1.30.45.1.7

CfprApFirmwareItemType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = bladeBios7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk20 = flexflashController22 = bladeSspOsController25 = graphicsCard · Integer32

Cisco Firepower firmware:PackItem:type managed object property

cfprApFirmwarePackItemVersion

1.3.6.1.4.1.9.9.826.2.1.30.45.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PackItem:version managed object property

cfprApFirmwarePlatformTable

1.3.6.1.4.1.9.9.826.2.1.30.46

Index: cfprApFirmwarePlatformInstanceId

Cisco Firepower firmware:Platform managed object table

cfprApFirmwarePlatformInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.46.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePlatformDn

1.3.6.1.4.1.9.9.826.2.1.30.46.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Platform:dn managed object property

cfprApFirmwarePlatformRn

1.3.6.1.4.1.9.9.826.2.1.30.46.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:rn managed object property

cfprApFirmwarePlatformAdminState

1.3.6.1.4.1.9.9.826.2.1.30.46.1.4

CfprApTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower firmware:Platform:adminState managed object property

cfprApFirmwarePlatformAutoDelete

1.3.6.1.4.1.9.9.826.2.1.30.46.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Platform:autoDelete managed object property

cfprApFirmwarePlatformDescr

1.3.6.1.4.1.9.9.826.2.1.30.46.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:descr managed object property

cfprApFirmwarePlatformIgnoreCap

1.3.6.1.4.1.9.9.826.2.1.30.46.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:Platform:ignoreCap managed object property

cfprApFirmwarePlatformIntId

1.3.6.1.4.1.9.9.826.2.1.30.46.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:intId managed object property

cfprApFirmwarePlatformName

1.3.6.1.4.1.9.9.826.2.1.30.46.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:name managed object property

cfprApFirmwarePlatformOperScheduler

1.3.6.1.4.1.9.9.826.2.1.30.46.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:operScheduler managed object property

cfprApFirmwarePlatformOperState

1.3.6.1.4.1.9.9.826.2.1.30.46.1.11

CfprApTrigTrigOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower firmware:Platform:operState managed object property

cfprApFirmwarePlatformOperVersion

1.3.6.1.4.1.9.9.826.2.1.30.46.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:operVersion managed object property

cfprApFirmwarePlatformPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.46.1.13

Gauge32

Cisco Firepower firmware:Platform:policyLevel managed object property

cfprApFirmwarePlatformPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.46.1.14

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:Platform:policyOwner managed object property

cfprApFirmwarePlatformScheduler

1.3.6.1.4.1.9.9.826.2.1.30.46.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Platform:scheduler managed object property

cfprApFirmwarePlatformBundleTypeCapProviderTable

1.3.6.1.4.1.9.9.826.2.1.30.47

Index: cfprApFirmwarePlatformBundleTypeCapProviderInstanceId

Cisco Firepower firmware:PlatformBundleTypeCapProvider managed object table

cfprApFirmwarePlatformBundleTypeCapProviderInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.47.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePlatformBundleTypeCapProviderDn

1.3.6.1.4.1.9.9.826.2.1.30.47.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:PlatformBundleTypeCapProvider:dn managed object property

cfprApFirmwarePlatformBundleTypeCapProviderRn

1.3.6.1.4.1.9.9.826.2.1.30.47.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformBundleTypeCapProvider:rn managed object property

cfprApFirmwarePlatformBundleTypeCapProviderDeleted

1.3.6.1.4.1.9.9.826.2.1.30.47.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:deleted managed object property

cfprApFirmwarePlatformBundleTypeCapProviderDeprecated

1.3.6.1.4.1.9.9.826.2.1.30.47.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:deprecated managed object property

cfprApFirmwarePlatformBundleTypeCapProviderElementLoadFailures

1.3.6.1.4.1.9.9.826.2.1.30.47.1.6

Gauge32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:elementLoa dFailures managed object property

cfprApFirmwarePlatformBundleTypeCapProviderElementsLoaded

1.3.6.1.4.1.9.9.826.2.1.30.47.1.7

Gauge32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:elementsLo aded managed object property

cfprApFirmwarePlatformBundleTypeCapProviderGencount

1.3.6.1.4.1.9.9.826.2.1.30.47.1.8

Gauge32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:gencount managed object property

cfprApFirmwarePlatformBundleTypeCapProviderLoadErrors

1.3.6.1.4.1.9.9.826.2.1.30.47.1.9

Gauge32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:loadErrors managed object property

cfprApFirmwarePlatformBundleTypeCapProviderLoadWarnings

1.3.6.1.4.1.9.9.826.2.1.30.47.1.10

Gauge32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:loadWarnin gs managed object property

cfprApFirmwarePlatformBundleTypeCapProviderMgmtPlaneVer

1.3.6.1.4.1.9.9.826.2.1.30.47.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformBundleTypeCapProvider:mgmtPlaneV er managed object property

cfprApFirmwarePlatformBundleTypeCapProviderModel

1.3.6.1.4.1.9.9.826.2.1.30.47.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformBundleTypeCapProvider:model managed object property

cfprApFirmwarePlatformBundleTypeCapProviderPlatformType

1.3.6.1.4.1.9.9.826.2.1.30.47.1.13

CfprApFirmwarePlatformType0 = ucs1 = ucsMini2 = sspBakerstreet3 = fpr2100 · Integer32

Cisco Firepower firmware:PlatformBundleTypeCapProvider:platformTy pe managed object property

cfprApFirmwarePlatformBundleTypeCapProviderVendor

1.3.6.1.4.1.9.9.826.2.1.30.47.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformBundleTypeCapProvider:vendor managed object property

cfprApFirmwarePlatformPackTable

1.3.6.1.4.1.9.9.826.2.1.30.48

Index: cfprApFirmwarePlatformPackInstanceId

Cisco Firepower firmware:PlatformPack managed object table

cfprApFirmwarePlatformPackInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.48.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePlatformPackDn

1.3.6.1.4.1.9.9.826.2.1.30.48.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:PlatformPack:dn managed object property

cfprApFirmwarePlatformPackRn

1.3.6.1.4.1.9.9.826.2.1.30.48.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:rn managed object property

cfprApFirmwarePlatformPackDescr

1.3.6.1.4.1.9.9.826.2.1.30.48.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:descr managed object property

cfprApFirmwarePlatformPackForceDeploy

1.3.6.1.4.1.9.9.826.2.1.30.48.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:PlatformPack:forceDeploy managed object property

cfprApFirmwarePlatformPackFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.48.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:fsmDescr managed object property

cfprApFirmwarePlatformPackFsmFlags

1.3.6.1.4.1.9.9.826.2.1.30.48.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:fsmFlags managed object property

cfprApFirmwarePlatformPackFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.48.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:fsmPrev managed object property

cfprApFirmwarePlatformPackFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.48.1.9

Gauge32

Cisco Firepower firmware:PlatformPack:fsmProgr managed object property

cfprApFirmwarePlatformPackFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.48.1.10

Gauge32

Cisco Firepower firmware:PlatformPack:fsmRmtInvErrCode managed object property

cfprApFirmwarePlatformPackFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.48.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:fsmRmtInvErrDescr managed object property

cfprApFirmwarePlatformPackFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.48.1.12

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:PlatformPack:fsmRmtInvRslt managed object property

cfprApFirmwarePlatformPackFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.48.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:fsmStageDescr managed object property

cfprApFirmwarePlatformPackFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.48.1.14

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:PlatformPack:fsmStamp managed object property

cfprApFirmwarePlatformPackFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.48.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:fsmStatus managed object property

cfprApFirmwarePlatformPackFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.48.1.16

Gauge32

Cisco Firepower firmware:PlatformPack:fsmTry managed object property

cfprApFirmwarePlatformPackIntId

1.3.6.1.4.1.9.9.826.2.1.30.48.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:intId managed object property

cfprApFirmwarePlatformPackMode

1.3.6.1.4.1.9.9.826.2.1.30.48.1.18

CfprApFirmwarePackMode0 = staged1 = oneShot · Integer32

Cisco Firepower firmware:PlatformPack:mode managed object property

cfprApFirmwarePlatformPackName

1.3.6.1.4.1.9.9.826.2.1.30.48.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:name managed object property

cfprApFirmwarePlatformPackPlatformBundleName

1.3.6.1.4.1.9.9.826.2.1.30.48.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:platformBundleName managed object property

cfprApFirmwarePlatformPackPlatformBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.48.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:platformBundleVersion managed object property

cfprApFirmwarePlatformPackPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.30.48.1.22

Gauge32

Cisco Firepower firmware:PlatformPack:policyLevel managed object property

cfprApFirmwarePlatformPackPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.30.48.1.23

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower firmware:PlatformPack:policyOwner managed object property

cfprApFirmwarePlatformPackPreviousBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.48.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPack:previousBundleVersion managed object property

cfprApFirmwarePlatformPackRestoreVersion

1.3.6.1.4.1.9.9.826.2.1.30.48.1.25

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:PlatformPack:restoreVersion managed object property

cfprApFirmwarePlatformPackSerializeHostUpgrade

1.3.6.1.4.1.9.9.826.2.1.30.48.1.26

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:PlatformPack:serializeHostUpgrade managed object property

cfprApFirmwarePlatformPackSkipManagerValidation

1.3.6.1.4.1.9.9.826.2.1.30.48.1.27

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower firmware:PlatformPack:skipManagerValidation managed object property

cfprApFirmwarePlatformPackStageSize

1.3.6.1.4.1.9.9.826.2.1.30.48.1.28

Gauge32

Cisco Firepower firmware:PlatformPack:stageSize managed object property

cfprApFirmwarePlatformPackUpdateTrigger

1.3.6.1.4.1.9.9.826.2.1.30.48.1.29

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:PlatformPack:updateTrigger managed object property

cfprApFirmwarePlatformPackFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.49

Index: cfprApFirmwarePlatformPackFsmInstanceId

Cisco Firepower firmware:PlatformPackFsm managed object table

cfprApFirmwarePlatformPackFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.49.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePlatformPackFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.49.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:PlatformPackFsm:dn managed object property

cfprApFirmwarePlatformPackFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.49.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPackFsm:rn managed object property

cfprApFirmwarePlatformPackFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.49.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:PlatformPackFsm:completionTime managed object property

cfprApFirmwarePlatformPackFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.49.1.5

CfprApFirmwarePlatformPackFsmCurrentFsm0 = nop34 = platformVersion · Integer32

Cisco Firepower firmware:PlatformPackFsm:currentFsm managed object property

cfprApFirmwarePlatformPackFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.49.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPackFsm:descr managed object property

cfprApFirmwarePlatformPackFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.49.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:PlatformPackFsm:fsmStatus managed object property

cfprApFirmwarePlatformPackFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.49.1.8

Gauge32

Cisco Firepower firmware:PlatformPackFsm:progress managed object property

cfprApFirmwarePlatformPackFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.49.1.9

Gauge32

Cisco Firepower firmware:PlatformPackFsm:rmtErrCode managed object property

cfprApFirmwarePlatformPackFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.49.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPackFsm:rmtErrDescr managed object property

cfprApFirmwarePlatformPackFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.49.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:PlatformPackFsm:rmtRslt managed object property

cfprApFirmwarePlatformPackFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.50

Index: cfprApFirmwarePlatformPackFsmStageInstanceId

Cisco Firepower firmware:PlatformPackFsmStage managed object table

cfprApFirmwarePlatformPackFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.50.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePlatformPackFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.50.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:PlatformPackFsmStage:dn managed object property

cfprApFirmwarePlatformPackFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.50.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPackFsmStage:rn managed object property

cfprApFirmwarePlatformPackFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.50.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPackFsmStage:descr managed object property

cfprApFirmwarePlatformPackFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.50.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:PlatformPackFsmStage:lastUpdateTime managed object property

cfprApFirmwarePlatformPackFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.50.1.6

CfprApFirmwarePlatformPackFsmStageName0 = nop34 = platformVersionBegin35 = platformVersionWaitForReady36 = platformVersionRestore618 = platformVersionFail619 = platformVersionSuccess · Integer32

Cisco Firepower firmware:PlatformPackFsmStage:name managed object property

cfprApFirmwarePlatformPackFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.50.1.7

Gauge32

Cisco Firepower firmware:PlatformPackFsmStage:order managed object property

cfprApFirmwarePlatformPackFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.50.1.8

Gauge32

Cisco Firepower firmware:PlatformPackFsmStage:retry managed object property

cfprApFirmwarePlatformPackFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.50.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:PlatformPackFsmStage:stageStatus managed object property

cfprApFirmwarePlatformPackFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.51

Index: cfprApFirmwarePlatformPackFsmTaskInstanceId

Cisco Firepower firmware:PlatformPackFsmTask managed object table

cfprApFirmwarePlatformPackFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.51.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwarePlatformPackFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.51.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:PlatformPackFsmTask:dn managed object property

cfprApFirmwarePlatformPackFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.51.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:PlatformPackFsmTask:rn managed object property

cfprApFirmwarePlatformPackFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.51.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:PlatformPackFsmTask:completion managed object property

cfprApFirmwarePlatformPackFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.51.1.5

CfprApFirmwarePlatformPackFsmTaskFlags · BITS

Cisco Firepower firmware:PlatformPackFsmTask:flags managed object property

cfprApFirmwarePlatformPackFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.51.1.6

CfprApFirmwarePlatformPackFsmTaskItem0 = nop34 = platformVersion · Integer32

Cisco Firepower firmware:PlatformPackFsmTask:item managed object property

cfprApFirmwarePlatformPackFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.51.1.7

Gauge32

Cisco Firepower firmware:PlatformPackFsmTask:seqId managed object property

cfprApFirmwareRackTable

1.3.6.1.4.1.9.9.826.2.1.30.52

Index: cfprApFirmwareRackInstanceId

Cisco Firepower firmware:Rack managed object table

cfprApFirmwareRackInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.52.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareRackDn

1.3.6.1.4.1.9.9.826.2.1.30.52.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Rack:dn managed object property

cfprApFirmwareRackRn

1.3.6.1.4.1.9.9.826.2.1.30.52.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Rack:rn managed object property

cfprApFirmwareRackOperVersion

1.3.6.1.4.1.9.9.826.2.1.30.52.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Rack:operVersion managed object property

cfprApFirmwareRommonInfoTable

1.3.6.1.4.1.9.9.826.2.1.30.53

Index: cfprApFirmwareRommonInfoInstanceId

Cisco Firepower firmware:RommonInfo managed object table

cfprApFirmwareRommonInfoInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.53.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareRommonInfoDn

1.3.6.1.4.1.9.9.826.2.1.30.53.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:RommonInfo:dn managed object property

cfprApFirmwareRommonInfoRn

1.3.6.1.4.1.9.9.826.2.1.30.53.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:rn managed object property

cfprApFirmwareRommonInfoFirmwareStatus

1.3.6.1.4.1.9.9.826.2.1.30.53.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:firmwareStatus managed object property

cfprApFirmwareRommonInfoFirmwareVersion

1.3.6.1.4.1.9.9.826.2.1.30.53.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:firmwareVersion managed object property

cfprApFirmwareRommonInfoFpgaVersion

1.3.6.1.4.1.9.9.826.2.1.30.53.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:fpgaVersion managed object property

cfprApFirmwareRommonInfoLanSpiVersion

1.3.6.1.4.1.9.9.826.2.1.30.53.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:lanSpiVersion managed object property

cfprApFirmwareRommonInfoPowerSequencerVersion

1.3.6.1.4.1.9.9.826.2.1.30.53.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:powerSequencerVersion managed object property

cfprApFirmwareRommonInfoRommonVersion

1.3.6.1.4.1.9.9.826.2.1.30.53.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:RommonInfo:rommonVersion managed object property

cfprApFirmwareRunningTable

1.3.6.1.4.1.9.9.826.2.1.30.54

Index: cfprApFirmwareRunningInstanceId

Cisco Firepower firmware:Running managed object table

cfprApFirmwareRunningInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.54.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareRunningDn

1.3.6.1.4.1.9.9.826.2.1.30.54.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Running:dn managed object property

cfprApFirmwareRunningRn

1.3.6.1.4.1.9.9.826.2.1.30.54.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Running:rn managed object property

cfprApFirmwareRunningDeployment

1.3.6.1.4.1.9.9.826.2.1.30.54.1.4

CfprApFirmwareRunningDeployment0 = unspecified1 = kernel2 = bootLoader3 = system · Integer32

Cisco Firepower firmware:Running:deployment managed object property

cfprApFirmwareRunningInvTag

1.3.6.1.4.1.9.9.826.2.1.30.54.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Running:invTag managed object property

cfprApFirmwareRunningPackageVersion

1.3.6.1.4.1.9.9.826.2.1.30.54.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Running:packageVersion managed object property

cfprApFirmwareRunningPlatformVersion

1.3.6.1.4.1.9.9.826.2.1.30.54.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Running:platformVersion managed object property

cfprApFirmwareRunningType

1.3.6.1.4.1.9.9.826.2.1.30.54.1.8

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:Running:type managed object property

cfprApFirmwareRunningVersion

1.3.6.1.4.1.9.9.826.2.1.30.54.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Running:version managed object property

cfprApFirmwareSpecTable

1.3.6.1.4.1.9.9.826.2.1.30.55

Index: cfprApFirmwareSpecInstanceId

Cisco Firepower firmware:Spec managed object table

cfprApFirmwareSpecInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.55.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSpecDn

1.3.6.1.4.1.9.9.826.2.1.30.55.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Spec:dn managed object property

cfprApFirmwareSpecRn

1.3.6.1.4.1.9.9.826.2.1.30.55.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Spec:rn managed object property

cfprApFirmwareSpecBundleVersion

1.3.6.1.4.1.9.9.826.2.1.30.55.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Spec:bundleVersion managed object property

cfprApFirmwareSpecEthEFIVersion

1.3.6.1.4.1.9.9.826.2.1.30.55.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Spec:ethEFIVersion managed object property

cfprApFirmwareSpecEthOptionRomVersion

1.3.6.1.4.1.9.9.826.2.1.30.55.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Spec:ethOptionRomVersion managed object property

cfprApFirmwareSpecFcFWVersion

1.3.6.1.4.1.9.9.826.2.1.30.55.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Spec:fcFWVersion managed object property

cfprApFirmwareSpecFcOptionRomVersion

1.3.6.1.4.1.9.9.826.2.1.30.55.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Spec:fcOptionRomVersion managed object property

cfprApFirmwareStatusTable

1.3.6.1.4.1.9.9.826.2.1.30.56

Index: cfprApFirmwareStatusInstanceId

Cisco Firepower firmware:Status managed object table

cfprApFirmwareStatusInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.56.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareStatusDn

1.3.6.1.4.1.9.9.826.2.1.30.56.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Status:dn managed object property

cfprApFirmwareStatusRn

1.3.6.1.4.1.9.9.826.2.1.30.56.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Status:rn managed object property

cfprApFirmwareStatusCimcVersion

1.3.6.1.4.1.9.9.826.2.1.30.56.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Status:cimcVersion managed object property

cfprApFirmwareStatusFirmwareState

1.3.6.1.4.1.9.9.826.2.1.30.56.1.5

CfprApFirmwareFirmwareState · BITS

Cisco Firepower firmware:Status:firmwareState managed object property

cfprApFirmwareStatusOperState

1.3.6.1.4.1.9.9.826.2.1.30.56.1.6

CfprApFirmwareImageState0 = ready1 = scheduled2 = updating3 = activating4 = failed5 = setStartup6 = rebooting7 = pendingNextBoot8 = throttled9 = upgrading10 = autoUpdating11 = autoActivating12 = pendingPowerCycle13 = badImage14 = rebuilding · Integer32

Cisco Firepower firmware:Status:operState managed object property

cfprApFirmwareStatusPackageVersion

1.3.6.1.4.1.9.9.826.2.1.30.56.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Status:packageVersion managed object property

cfprApFirmwareStatusPldVersion

1.3.6.1.4.1.9.9.826.2.1.30.56.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Status:pldVersion managed object property

cfprApFirmwareSupFirmwareTable

1.3.6.1.4.1.9.9.826.2.1.30.57

Index: cfprApFirmwareSupFirmwareInstanceId

Cisco Firepower firmware:SupFirmware managed object table

cfprApFirmwareSupFirmwareInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.57.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSupFirmwareDn

1.3.6.1.4.1.9.9.826.2.1.30.57.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SupFirmware:dn managed object property

cfprApFirmwareSupFirmwareRn

1.3.6.1.4.1.9.9.826.2.1.30.57.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:rn managed object property

cfprApFirmwareSupFirmwareFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.57.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:fsmDescr managed object property

cfprApFirmwareSupFirmwareFsmFlags

1.3.6.1.4.1.9.9.826.2.1.30.57.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:fsmFlags managed object property

cfprApFirmwareSupFirmwareFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.57.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:fsmPrev managed object property

cfprApFirmwareSupFirmwareFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.57.1.7

Gauge32

Cisco Firepower firmware:SupFirmware:fsmProgr managed object property

cfprApFirmwareSupFirmwareFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.57.1.8

Gauge32

Cisco Firepower firmware:SupFirmware:fsmRmtInvErrCode managed object property

cfprApFirmwareSupFirmwareFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.57.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:fsmRmtInvErrDescr managed object property

cfprApFirmwareSupFirmwareFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.57.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:SupFirmware:fsmRmtInvRslt managed object property

cfprApFirmwareSupFirmwareFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.57.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:fsmStageDescr managed object property

cfprApFirmwareSupFirmwareFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.57.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:SupFirmware:fsmStamp managed object property

cfprApFirmwareSupFirmwareFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.57.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:fsmStatus managed object property

cfprApFirmwareSupFirmwareFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.57.1.14

Gauge32

Cisco Firepower firmware:SupFirmware:fsmTry managed object property

cfprApFirmwareSupFirmwareOperState

1.3.6.1.4.1.9.9.826.2.1.30.57.1.15

CfprApFirmwareFwUpgradeState0 = ready1 = inProgress2 = upgrading3 = updatingImageVersion4 = updatingPackageVersion5 = failed6 = failedUpgrade · Integer32

Cisco Firepower firmware:SupFirmware:operState managed object property

cfprApFirmwareSupFirmwarePackVersion

1.3.6.1.4.1.9.9.826.2.1.30.57.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:packVersion managed object property

cfprApFirmwareSupFirmwareState

1.3.6.1.4.1.9.9.826.2.1.30.57.1.17

CfprApFirmwareFwState0 = unknown1 = sameRelease2 = compatible3 = incompatible4 = multipleReleases · Integer32

Cisco Firepower firmware:SupFirmware:state managed object property

cfprApFirmwareSupFirmwareUpgradeStatus

1.3.6.1.4.1.9.9.826.2.1.30.57.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmware:upgradeStatus managed object property

cfprApFirmwareSupFirmwareFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.58

Index: cfprApFirmwareSupFirmwareFsmInstanceId

Cisco Firepower firmware:SupFirmwareFsm managed object table

cfprApFirmwareSupFirmwareFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.58.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSupFirmwareFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.58.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SupFirmwareFsm:dn managed object property

cfprApFirmwareSupFirmwareFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.58.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmwareFsm:rn managed object property

cfprApFirmwareSupFirmwareFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.58.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:SupFirmwareFsm:completionTime managed object property

cfprApFirmwareSupFirmwareFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.58.1.5

CfprApFirmwareSupFirmwareFsmCurrentFsm0 = nop56 = deploy · Integer32

Cisco Firepower firmware:SupFirmwareFsm:currentFsm managed object property

cfprApFirmwareSupFirmwareFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.58.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmwareFsm:descr managed object property

cfprApFirmwareSupFirmwareFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.58.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:SupFirmwareFsm:fsmStatus managed object property

cfprApFirmwareSupFirmwareFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.58.1.8

Gauge32

Cisco Firepower firmware:SupFirmwareFsm:progress managed object property

cfprApFirmwareSupFirmwareFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.58.1.9

Gauge32

Cisco Firepower firmware:SupFirmwareFsm:rmtErrCode managed object property

cfprApFirmwareSupFirmwareFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.58.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmwareFsm:rmtErrDescr managed object property

cfprApFirmwareSupFirmwareFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.58.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:SupFirmwareFsm:rmtRslt managed object property

cfprApFirmwareSupFirmwareFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.59

Index: cfprApFirmwareSupFirmwareFsmStageInstanceId

Cisco Firepower firmware:SupFirmwareFsmStage managed object table

cfprApFirmwareSupFirmwareFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.59.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSupFirmwareFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.59.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SupFirmwareFsmStage:dn managed object property

cfprApFirmwareSupFirmwareFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.59.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmwareFsmStage:rn managed object property

cfprApFirmwareSupFirmwareFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.59.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmwareFsmStage:descr managed object property

cfprApFirmwareSupFirmwareFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.59.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:SupFirmwareFsmStage:lastUpdateTime managed object property

cfprApFirmwareSupFirmwareFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.59.1.6

CfprApFirmwareSupFirmwareFsmStageName0 = nop56 = deployBegin57 = deployWaitForDeploy58 = deployValidateFirmwarePack59 = deployDebundlePort60 = deployPollDebundlePort61 = deployActivateFirmwarePack62 = deployPollActivateOfFirmwarePack63 = deployUpdateImageVersion64 = deployWaitForFirmwareVersionUpdate65 = deployUpdatePackageVersion66 = deployCompleteFirmwareUpgrade620 = deployFail621 = deploySuccess · Integer32

Cisco Firepower firmware:SupFirmwareFsmStage:name managed object property

cfprApFirmwareSupFirmwareFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.59.1.7

Gauge32

Cisco Firepower firmware:SupFirmwareFsmStage:order managed object property

cfprApFirmwareSupFirmwareFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.59.1.8

Gauge32

Cisco Firepower firmware:SupFirmwareFsmStage:retry managed object property

cfprApFirmwareSupFirmwareFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.59.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:SupFirmwareFsmStage:stageStatus managed object property

cfprApFirmwareSupFirmwareFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.60

Index: cfprApFirmwareSupFirmwareFsmTaskInstanceId

Cisco Firepower firmware:SupFirmwareFsmTask managed object table

cfprApFirmwareSupFirmwareFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.60.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSupFirmwareFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.60.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SupFirmwareFsmTask:dn managed object property

cfprApFirmwareSupFirmwareFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.60.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SupFirmwareFsmTask:rn managed object property

cfprApFirmwareSupFirmwareFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.60.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:SupFirmwareFsmTask:completion managed object property

cfprApFirmwareSupFirmwareFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.60.1.5

CfprApFirmwareSupFirmwareFsmTaskFlags · BITS

Cisco Firepower firmware:SupFirmwareFsmTask:flags managed object property

cfprApFirmwareSupFirmwareFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.60.1.6

CfprApFirmwareSupFirmwareFsmTaskItem0 = nop56 = deploy · Integer32

Cisco Firepower firmware:SupFirmwareFsmTask:item managed object property

cfprApFirmwareSupFirmwareFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.60.1.7

Gauge32

Cisco Firepower firmware:SupFirmwareFsmTask:seqId managed object property

cfprApFirmwareSystemTable

1.3.6.1.4.1.9.9.826.2.1.30.61

Index: cfprApFirmwareSystemInstanceId

Cisco Firepower firmware:System managed object table

cfprApFirmwareSystemInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.61.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSystemDn

1.3.6.1.4.1.9.9.826.2.1.30.61.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:System:dn managed object property

cfprApFirmwareSystemRn

1.3.6.1.4.1.9.9.826.2.1.30.61.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:rn managed object property

cfprApFirmwareSystemFsmDescr

1.3.6.1.4.1.9.9.826.2.1.30.61.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fsmDescr managed object property

cfprApFirmwareSystemFsmFlags

1.3.6.1.4.1.9.9.826.2.1.30.61.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fsmFlags managed object property

cfprApFirmwareSystemFsmPrev

1.3.6.1.4.1.9.9.826.2.1.30.61.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fsmPrev managed object property

cfprApFirmwareSystemFsmProgr

1.3.6.1.4.1.9.9.826.2.1.30.61.1.7

Gauge32

Cisco Firepower firmware:System:fsmProgr managed object property

cfprApFirmwareSystemFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.30.61.1.8

Gauge32

Cisco Firepower firmware:System:fsmRmtInvErrCode managed object property

cfprApFirmwareSystemFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.61.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fsmRmtInvErrDescr managed object property

cfprApFirmwareSystemFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.30.61.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:System:fsmRmtInvRslt managed object property

cfprApFirmwareSystemFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.30.61.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fsmStageDescr managed object property

cfprApFirmwareSystemFsmStamp

1.3.6.1.4.1.9.9.826.2.1.30.61.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:System:fsmStamp managed object property

cfprApFirmwareSystemFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.61.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fsmStatus managed object property

cfprApFirmwareSystemFsmTry

1.3.6.1.4.1.9.9.826.2.1.30.61.1.14

Gauge32

Cisco Firepower firmware:System:fsmTry managed object property

cfprApFirmwareSystemFwUpgradeBitmap

1.3.6.1.4.1.9.9.826.2.1.30.61.1.15

Gauge32

Cisco Firepower firmware:System:fwUpgradeBitmap managed object property

cfprApFirmwareSystemFwUpgradeStatus

1.3.6.1.4.1.9.9.826.2.1.30.61.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:fwUpgradeStatus managed object property

cfprApFirmwareSystemOperState

1.3.6.1.4.1.9.9.826.2.1.30.61.1.17

CfprApFirmwareInstallState0 = ready1 = scheduled2 = inProgress3 = failed4 = pendingUserAck5 = startPendingExtPermission · Integer32

Cisco Firepower firmware:System:operState managed object property

cfprApFirmwareSystemPackVersion

1.3.6.1.4.1.9.9.826.2.1.30.61.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:packVersion managed object property

cfprApFirmwareSystemScheduledInstallTime

1.3.6.1.4.1.9.9.826.2.1.30.61.1.19

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:System:scheduledInstallTime managed object property

cfprApFirmwareSystemState

1.3.6.1.4.1.9.9.826.2.1.30.61.1.20

CfprApFirmwareFwState0 = unknown1 = sameRelease2 = compatible3 = incompatible4 = multipleReleases · Integer32

Cisco Firepower firmware:System:state managed object property

cfprApFirmwareSystemUpgradeState

1.3.6.1.4.1.9.9.826.2.1.30.61.1.21

CfprApFirmwareUpgradeState0 = ready1 = validatingImages2 = removingApplication3 = updatingManagerStartup4 = upgradingNpu5 = upgradingSystem6 = upgradingFirmware7 = rebootingSystem8 = waitingSystemReady9 = checkingServiceManager10 = upgradingServiceManager11 = updatingSoftwarePackVersion12 = updateSoftwarePackCompleted13 = installingApplication14 = failedImageValidation15 = failedToRemoveApplication16 = failedToUpgradeNpuImage17 = failedToSetServiceMgrVersion18 = failedToUpgradeSystemImage19 = failedToRebootSystem20 = failedToUpgradeFirmware21 = failedToUpdatePackageVersion22 = failedToUpgradeServiceManager23 = failedToInstallApplication · Integer32

Cisco Firepower firmware:System:upgradeState managed object property

cfprApFirmwareSystemUpgradeStatus

1.3.6.1.4.1.9.9.826.2.1.30.61.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:System:upgradeStatus managed object property

cfprApFirmwareSystemCompCheckResultTable

1.3.6.1.4.1.9.9.826.2.1.30.62

Index: cfprApFirmwareSystemCompCheckResultInstanceId

Cisco Firepower firmware:SystemCompCheckResult managed object table

cfprApFirmwareSystemCompCheckResultInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.62.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSystemCompCheckResultDn

1.3.6.1.4.1.9.9.826.2.1.30.62.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SystemCompCheckResult:dn managed object property

cfprApFirmwareSystemCompCheckResultRn

1.3.6.1.4.1.9.9.826.2.1.30.62.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemCompCheckResult:rn managed object property

cfprApFirmwareSystemCompCheckResultKeyDescr

1.3.6.1.4.1.9.9.826.2.1.30.62.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemCompCheckResult:keyDescr managed object property

cfprApFirmwareSystemCompCheckResultKeyDn

1.3.6.1.4.1.9.9.826.2.1.30.62.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemCompCheckResult:keyDn managed object property

cfprApFirmwareSystemCompCheckResultNonCompDescr

1.3.6.1.4.1.9.9.826.2.1.30.62.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemCompCheckResult:nonCompDescr managed object property

cfprApFirmwareSystemCompCheckResultNonCompDns

1.3.6.1.4.1.9.9.826.2.1.30.62.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemCompCheckResult:nonCompDns managed object property

cfprApFirmwareSystemCompCheckResultSubject

1.3.6.1.4.1.9.9.826.2.1.30.62.1.8

CfprApFirmwareEquipmentType0 = unknown1 = system2 = switch3 = iocard4 = server5 = cimc6 = adaptor7 = storageController8 = boardController9 = bios10 = serviceProfile11 = graphicsCard · Integer32

Cisco Firepower firmware:SystemCompCheckResult:subject managed object property

cfprApFirmwareSystemFsmTable

1.3.6.1.4.1.9.9.826.2.1.30.63

Index: cfprApFirmwareSystemFsmInstanceId

Cisco Firepower firmware:SystemFsm managed object table

cfprApFirmwareSystemFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.63.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSystemFsmDn

1.3.6.1.4.1.9.9.826.2.1.30.63.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SystemFsm:dn managed object property

cfprApFirmwareSystemFsmRn

1.3.6.1.4.1.9.9.826.2.1.30.63.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemFsm:rn managed object property

cfprApFirmwareSystemFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.30.63.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:SystemFsm:completionTime managed object property

cfprApFirmwareSystemFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.30.63.1.5

CfprApFirmwareSystemFsmCurrentFsm0 = nop37 = deploy67 = applyCatalogPack · Integer32

Cisco Firepower firmware:SystemFsm:currentFsm managed object property

cfprApFirmwareSystemFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.30.63.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemFsm:descr managed object property

cfprApFirmwareSystemFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.30.63.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:SystemFsm:fsmStatus managed object property

cfprApFirmwareSystemFsmProgress

1.3.6.1.4.1.9.9.826.2.1.30.63.1.8

Gauge32

Cisco Firepower firmware:SystemFsm:progress managed object property

cfprApFirmwareSystemFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.30.63.1.9

Gauge32

Cisco Firepower firmware:SystemFsm:rmtErrCode managed object property

cfprApFirmwareSystemFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.30.63.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemFsm:rmtErrDescr managed object property

cfprApFirmwareSystemFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.30.63.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower firmware:SystemFsm:rmtRslt managed object property

cfprApFirmwareSystemFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.30.64

Index: cfprApFirmwareSystemFsmStageInstanceId

Cisco Firepower firmware:SystemFsmStage managed object table

cfprApFirmwareSystemFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.64.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSystemFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.30.64.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SystemFsmStage:dn managed object property

cfprApFirmwareSystemFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.30.64.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemFsmStage:rn managed object property

cfprApFirmwareSystemFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.30.64.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemFsmStage:descr managed object property

cfprApFirmwareSystemFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.30.64.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:SystemFsmStage:lastUpdateTime managed object property

cfprApFirmwareSystemFsmStageName

1.3.6.1.4.1.9.9.826.2.1.30.64.1.6

CfprApFirmwareSystemFsmStageName0 = nop37 = deployBegin38 = deployWaitForDeploy39 = deployValidateApplicationPack40 = deployDeleteCurrentApplication41 = deployPollDeleteCurrentApplicationStatus42 = deploySetStartupServiceManagerVersion43 = deployPollStartupServiceManagerStatus44 = deployActivateNpuImage45 = deployPollNpuActivationStatus46 = deployActivateSystemImage47 = deployActivateFirmwareImage48 = deployRebootSystemForImageUpgrade49 = deployWaitForSystemReady50 = deployPollSystemActivationStatus51 = deployActivateManagerImage52 = deployPollManagerActivationStatus53 = deployActivateApplicationImage54 = deployPollApplicationActivationStatus55 = deployCompleteFirmwareUpgrade67 = applyCatalogPackBegin68 = applyCatalogPackResolveDistributableNames69 = applyCatalogPackResolveDistributable70 = applyCatalogPackResolveImages71 = applyCatalogPackActivateCatalog622 = applyCatalogPackFail623 = applyCatalogPackSuccess624 = deployFail625 = deploySuccess834 = deployCheckFirmwareUpgradeStatus · Integer32

Cisco Firepower firmware:SystemFsmStage:name managed object property

cfprApFirmwareSystemFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.30.64.1.7

Gauge32

Cisco Firepower firmware:SystemFsmStage:order managed object property

cfprApFirmwareSystemFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.30.64.1.8

Gauge32

Cisco Firepower firmware:SystemFsmStage:retry managed object property

cfprApFirmwareSystemFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.30.64.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower firmware:SystemFsmStage:stageStatus managed object property

cfprApFirmwareSystemFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.30.65

Index: cfprApFirmwareSystemFsmTaskInstanceId

Cisco Firepower firmware:SystemFsmTask managed object table

cfprApFirmwareSystemFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.65.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareSystemFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.30.65.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:SystemFsmTask:dn managed object property

cfprApFirmwareSystemFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.30.65.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:SystemFsmTask:rn managed object property

cfprApFirmwareSystemFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.30.65.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower firmware:SystemFsmTask:completion managed object property

cfprApFirmwareSystemFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.30.65.1.5

CfprApFirmwareSystemFsmTaskFlags · BITS

Cisco Firepower firmware:SystemFsmTask:flags managed object property

cfprApFirmwareSystemFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.30.65.1.6

CfprApFirmwareSystemFsmTaskItem0 = nop37 = deploy67 = applyCatalogPack · Integer32

Cisco Firepower firmware:SystemFsmTask:item managed object property

cfprApFirmwareSystemFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.30.65.1.7

Gauge32

Cisco Firepower firmware:SystemFsmTask:seqId managed object property

cfprApFirmwareTypeTable

1.3.6.1.4.1.9.9.826.2.1.30.66

Index: cfprApFirmwareTypeInstanceId

Cisco Firepower firmware:Type managed object table

cfprApFirmwareTypeInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.66.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareTypeDn

1.3.6.1.4.1.9.9.826.2.1.30.66.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Type:dn managed object property

cfprApFirmwareTypeRn

1.3.6.1.4.1.9.9.826.2.1.30.66.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Type:rn managed object property

cfprApFirmwareTypeEp

1.3.6.1.4.1.9.9.826.2.1.30.66.1.4

CfprApFirmwareType0 = unspecified1 = switchKernel2 = switchSoftware3 = system4 = bladeController5 = iocard6 = fex7 = adaptor8 = storageController9 = hostNic10 = hostHba11 = hostHbaOptionrom12 = hostNicOptionrom13 = boardController14 = localDisk15 = diag16 = catalog17 = mgmtExt18 = debugPlugIn19 = switch20 = flexflashController22 = bladeSspOsController23 = fxosCspCompatibility24 = fprRommon25 = graphicsCard26 = fprFirmware27 = fprCspapp · Integer32

Cisco Firepower firmware:Type:ep managed object property

cfprApFirmwareTypeInvTag

1.3.6.1.4.1.9.9.826.2.1.30.66.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Type:invTag managed object property

cfprApFirmwareTypeMaxVer

1.3.6.1.4.1.9.9.826.2.1.30.66.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Type:maxVer managed object property

cfprApFirmwareTypeMinVer

1.3.6.1.4.1.9.9.826.2.1.30.66.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Type:minVer managed object property

cfprApFirmwareTypeScheduledInstallTime

1.3.6.1.4.1.9.9.826.2.1.30.66.1.8

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:Type:scheduledInstallTime managed object property

cfprApFirmwareUcscInfoTable

1.3.6.1.4.1.9.9.826.2.1.30.67

Index: cfprApFirmwareUcscInfoInstanceId

Cisco Firepower firmware:UcscInfo managed object table

cfprApFirmwareUcscInfoInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.67.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareUcscInfoDn

1.3.6.1.4.1.9.9.826.2.1.30.67.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:UcscInfo:dn managed object property

cfprApFirmwareUcscInfoRn

1.3.6.1.4.1.9.9.826.2.1.30.67.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UcscInfo:rn managed object property

cfprApFirmwareUcscInfoConnProtocol

1.3.6.1.4.1.9.9.826.2.1.30.67.1.4

CfprApExtpolConnProtocol0 = ipv41 = ipv62 = unknown · Integer32

Cisco Firepower firmware:UcscInfo:connProtocol managed object property

cfprApFirmwareUcscInfoHost

1.3.6.1.4.1.9.9.826.2.1.30.67.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UcscInfo:host managed object property

cfprApFirmwareUcscInfoVersion

1.3.6.1.4.1.9.9.826.2.1.30.67.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UcscInfo:version managed object property

cfprApFirmwareUpdatableTable

1.3.6.1.4.1.9.9.826.2.1.30.68

Index: cfprApFirmwareUpdatableInstanceId

Cisco Firepower firmware:Updatable managed object table

cfprApFirmwareUpdatableInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.68.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareUpdatableDn

1.3.6.1.4.1.9.9.826.2.1.30.68.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:Updatable:dn managed object property

cfprApFirmwareUpdatableRn

1.3.6.1.4.1.9.9.826.2.1.30.68.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Updatable:rn managed object property

cfprApFirmwareUpdatableAdminState

1.3.6.1.4.1.9.9.826.2.1.30.68.1.4

CfprApFirmwareTriggerState0 = triggered1 = trigger · Integer32

Cisco Firepower firmware:Updatable:adminState managed object property

cfprApFirmwareUpdatableDeployment

1.3.6.1.4.1.9.9.826.2.1.30.68.1.5

CfprApFirmwareUpdatableDeployment0 = unspecified4 = backup · Integer32

Cisco Firepower firmware:Updatable:deployment managed object property

cfprApFirmwareUpdatableOperState

1.3.6.1.4.1.9.9.826.2.1.30.68.1.6

CfprApFirmwareImageState0 = ready1 = scheduled2 = updating3 = activating4 = failed5 = setStartup6 = rebooting7 = pendingNextBoot8 = throttled9 = upgrading10 = autoUpdating11 = autoActivating12 = pendingPowerCycle13 = badImage14 = rebuilding · Integer32

Cisco Firepower firmware:Updatable:operState managed object property

cfprApFirmwareUpdatableOperStateQual

1.3.6.1.4.1.9.9.826.2.1.30.68.1.7

CfprApFirmwareImageError0 = none1 = checksumFailure2 = filesystemError3 = mgmtConnectError4 = bootConfMissing5 = crcFailure6 = unknownError7 = rebuilding · Integer32

Cisco Firepower firmware:Updatable:operStateQual managed object property

cfprApFirmwareUpdatablePrevVersion

1.3.6.1.4.1.9.9.826.2.1.30.68.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Updatable:prevVersion managed object property

cfprApFirmwareUpdatableVersion

1.3.6.1.4.1.9.9.826.2.1.30.68.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:Updatable:version managed object property

cfprApFirmwareUpgradeConstraintTable

1.3.6.1.4.1.9.9.826.2.1.30.69

Index: cfprApFirmwareUpgradeConstraintInstanceId

Cisco Firepower firmware:UpgradeConstraint managed object table

cfprApFirmwareUpgradeConstraintInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.69.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareUpgradeConstraintDn

1.3.6.1.4.1.9.9.826.2.1.30.69.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:UpgradeConstraint:dn managed object property

cfprApFirmwareUpgradeConstraintRn

1.3.6.1.4.1.9.9.826.2.1.30.69.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeConstraint:rn managed object property

cfprApFirmwareUpgradeConstraintMinVer

1.3.6.1.4.1.9.9.826.2.1.30.69.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeConstraint:minVer managed object property

cfprApFirmwareUpgradeDetailTable

1.3.6.1.4.1.9.9.826.2.1.30.70

Index: cfprApFirmwareUpgradeDetailInstanceId

Cisco Firepower firmware:UpgradeDetail managed object table

cfprApFirmwareUpgradeDetailInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.70.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareUpgradeDetailDn

1.3.6.1.4.1.9.9.826.2.1.30.70.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:UpgradeDetail:dn managed object property

cfprApFirmwareUpgradeDetailRn

1.3.6.1.4.1.9.9.826.2.1.30.70.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeDetail:rn managed object property

cfprApFirmwareUpgradeDetailCategory

1.3.6.1.4.1.9.9.826.2.1.30.70.1.4

CfprApFirmwareUpgradeCategory0 = other1 = dataLoad2 = catalog3 = config4 = serverReboot5 = faults · Integer32

Cisco Firepower firmware:UpgradeDetail:category managed object property

cfprApFirmwareUpgradeDetailDescription

1.3.6.1.4.1.9.9.826.2.1.30.70.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeDetail:description managed object property

cfprApFirmwareUpgradeDetailId

1.3.6.1.4.1.9.9.826.2.1.30.70.1.6

Gauge32

Cisco Firepower firmware:UpgradeDetail:id managed object property

cfprApFirmwareUpgradeDetailSeverity

1.3.6.1.4.1.9.9.826.2.1.30.70.1.7

CfprApFirmwareUpgradeSeverity0 = unknown1 = fatal2 = error3 = warn4 = info · Integer32

Cisco Firepower firmware:UpgradeDetail:severity managed object property

cfprApFirmwareUpgradeInfoTable

1.3.6.1.4.1.9.9.826.2.1.30.71

Index: cfprApFirmwareUpgradeInfoInstanceId

Cisco Firepower firmware:UpgradeInfo managed object table

cfprApFirmwareUpgradeInfoInstanceId

1.3.6.1.4.1.9.9.826.2.1.30.71.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApFirmwareUpgradeInfoDn

1.3.6.1.4.1.9.9.826.2.1.30.71.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower firmware:UpgradeInfo:dn managed object property

cfprApFirmwareUpgradeInfoRn

1.3.6.1.4.1.9.9.826.2.1.30.71.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeInfo:rn managed object property

cfprApFirmwareUpgradeInfoMessage

1.3.6.1.4.1.9.9.826.2.1.30.71.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeInfo:message managed object property

cfprApFirmwareUpgradeInfoTimeStamp

1.3.6.1.4.1.9.9.826.2.1.30.71.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower firmware:UpgradeInfo:timeStamp managed object property

cfprApFirmwareUpgradeInfoValidateStatus

1.3.6.1.4.1.9.9.826.2.1.30.71.1.6

CfprApFirmwareUpgradeStatus0 = unknown1 = inProgress2 = failed3 = success4 = warnings5 = skipped · Integer32

Cisco Firepower firmware:UpgradeInfo:validateStatus managed object property

cfprApFirmwareUpgradeInfoVersion

1.3.6.1.4.1.9.9.826.2.1.30.71.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower firmware:UpgradeInfo:version managed object property

↑ To TOC