EZ5 MIB Catalog

CISCO-FIREPOWER-AP-IDENT-MIB

2023-01-25

MIB representation of the Cisco Firepower IDENT management information model package

Download CISCO-FIREPOWER-AP-IDENT-MIB.txt Open CISCO-FIREPOWER-AP-IDENT-MIB.txt in a new tab

TABLES (12)

Tables (12)

NameOID
cfprApIdentIdentCtxTable1.3.6.1.4.1.9.9.826.2.1.36.1
cfprApIdentIdentRequestTable1.3.6.1.4.1.9.9.826.2.1.36.2
cfprApIdentIdentRequestFsmTable1.3.6.1.4.1.9.9.826.2.1.36.3
cfprApIdentIdentRequestFsmStageTable1.3.6.1.4.1.9.9.826.2.1.36.4
cfprApIdentIdentRequestFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.36.5
cfprApIdentMetaSystemTable1.3.6.1.4.1.9.9.826.2.1.36.6
cfprApIdentMetaSystemFsmTable1.3.6.1.4.1.9.9.826.2.1.36.7
cfprApIdentMetaSystemFsmStageTable1.3.6.1.4.1.9.9.826.2.1.36.8
cfprApIdentMetaSystemFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.36.9
cfprApIdentMetaVerseTable1.3.6.1.4.1.9.9.826.2.1.36.10
cfprApIdentRequestEpTable1.3.6.1.4.1.9.9.826.2.1.36.11
cfprApIdentSysInfoTable1.3.6.1.4.1.9.9.826.2.1.36.12

END OF TOC

Table details

cfprApIdentIdentCtxTable

1.3.6.1.4.1.9.9.826.2.1.36.1

Index: cfprApIdentIdentCtxInstanceId

Cisco Firepower ident:IdentCtx managed object table

cfprApIdentIdentCtxInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.1.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentIdentCtxDn

1.3.6.1.4.1.9.9.826.2.1.36.1.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:IdentCtx:dn managed object property

cfprApIdentIdentCtxRn

1.3.6.1.4.1.9.9.826.2.1.36.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:rn managed object property

cfprApIdentIdentCtxAssigned

1.3.6.1.4.1.9.9.826.2.1.36.1.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:assigned managed object property

cfprApIdentIdentCtxConsDn

1.3.6.1.4.1.9.9.826.2.1.36.1.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:consDn managed object property

cfprApIdentIdentCtxConsType

1.3.6.1.4.1.9.9.826.2.1.36.1.1.6

CfprApIdentConsType1 = vnic2 = vhba3 = server4 = chassis5 = vm6 = vmnic · Integer32

Cisco Firepower ident:IdentCtx:consType managed object property

cfprApIdentIdentCtxDefinedInIdm

1.3.6.1.4.1.9.9.826.2.1.36.1.1.7

CfprApIdentIdDefinedInIdm0 = no1 = yes · Integer32

Cisco Firepower ident:IdentCtx:definedInIdm managed object property

cfprApIdentIdentCtxGlobalAssignedCnt

1.3.6.1.4.1.9.9.826.2.1.36.1.1.8

Gauge32

Cisco Firepower ident:IdentCtx:globalAssignedCnt managed object property

cfprApIdentIdentCtxGlobalDefinedCnt

1.3.6.1.4.1.9.9.826.2.1.36.1.1.9

Gauge32

Cisco Firepower ident:IdentCtx:globalDefinedCnt managed object property

cfprApIdentIdentCtxIdentPoolName

1.3.6.1.4.1.9.9.826.2.1.36.1.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:identPoolName managed object property

cfprApIdentIdentCtxIdentType

1.3.6.1.4.1.9.9.826.2.1.36.1.1.11

CfprApIdentIdentType1 = mac2 = wwnn3 = wwpn4 = uuid5 = vlan6 = ipV47 = ipV68 = iqn · Integer32

Cisco Firepower ident:IdentCtx:identType managed object property

cfprApIdentIdentCtxIntent

1.3.6.1.4.1.9.9.826.2.1.36.1.1.12

CfprApIdentIdentReqIntent1 = requisition2 = assign3 = unassign4 = addPooled5 = deletePooled6 = checkDuplicateId · Integer32

Cisco Firepower ident:IdentCtx:intent managed object property

cfprApIdentIdentCtxIsAssignedLocally

1.3.6.1.4.1.9.9.826.2.1.36.1.1.13

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower ident:IdentCtx:isAssignedLocally managed object property

cfprApIdentIdentCtxPoolDn

1.3.6.1.4.1.9.9.826.2.1.36.1.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:poolDn managed object property

cfprApIdentIdentCtxPoolOrgDn

1.3.6.1.4.1.9.9.826.2.1.36.1.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:poolOrgDn managed object property

cfprApIdentIdentCtxPooledId

1.3.6.1.4.1.9.9.826.2.1.36.1.1.16

Gauge32

Cisco Firepower ident:IdentCtx:pooledId managed object property

cfprApIdentIdentCtxRetStatus

1.3.6.1.4.1.9.9.826.2.1.36.1.1.17

CfprApIdentRetStatus1 = succeeded2 = assignedByOther3 = outOfSync4 = failed5 = synced · Integer32

Cisco Firepower ident:IdentCtx:retStatus managed object property

cfprApIdentIdentCtxSeqNum

1.3.6.1.4.1.9.9.826.2.1.36.1.1.18

Gauge32

Cisco Firepower ident:IdentCtx:seqNum managed object property

cfprApIdentIdentCtxSupplId1

1.3.6.1.4.1.9.9.826.2.1.36.1.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:supplId1 managed object property

cfprApIdentIdentCtxSupplId2

1.3.6.1.4.1.9.9.826.2.1.36.1.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:supplId2 managed object property

cfprApIdentIdentCtxSupplId3

1.3.6.1.4.1.9.9.826.2.1.36.1.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:supplId3 managed object property

cfprApIdentIdentCtxSupplId4

1.3.6.1.4.1.9.9.826.2.1.36.1.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentCtx:supplId4 managed object property

cfprApIdentIdentRequestTable

1.3.6.1.4.1.9.9.826.2.1.36.2

Index: cfprApIdentIdentRequestInstanceId

Cisco Firepower ident:IdentRequest managed object table

cfprApIdentIdentRequestInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.2.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentIdentRequestDn

1.3.6.1.4.1.9.9.826.2.1.36.2.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:IdentRequest:dn managed object property

cfprApIdentIdentRequestRn

1.3.6.1.4.1.9.9.826.2.1.36.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:rn managed object property

cfprApIdentIdentRequestEpDn

1.3.6.1.4.1.9.9.826.2.1.36.2.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:epDn managed object property

cfprApIdentIdentRequestFsmDescr

1.3.6.1.4.1.9.9.826.2.1.36.2.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:fsmDescr managed object property

cfprApIdentIdentRequestFsmPrev

1.3.6.1.4.1.9.9.826.2.1.36.2.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:fsmPrev managed object property

cfprApIdentIdentRequestFsmProgr

1.3.6.1.4.1.9.9.826.2.1.36.2.1.7

Gauge32

Cisco Firepower ident:IdentRequest:fsmProgr managed object property

cfprApIdentIdentRequestFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.36.2.1.8

Gauge32

Cisco Firepower ident:IdentRequest:fsmRmtInvErrCode managed object property

cfprApIdentIdentRequestFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.36.2.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:fsmRmtInvErrDescr managed object property

cfprApIdentIdentRequestFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.36.2.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower ident:IdentRequest:fsmRmtInvRslt managed object property

cfprApIdentIdentRequestFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.36.2.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:fsmStageDescr managed object property

cfprApIdentIdentRequestFsmStamp

1.3.6.1.4.1.9.9.826.2.1.36.2.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower ident:IdentRequest:fsmStamp managed object property

cfprApIdentIdentRequestFsmStatus

1.3.6.1.4.1.9.9.826.2.1.36.2.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequest:fsmStatus managed object property

cfprApIdentIdentRequestFsmTry

1.3.6.1.4.1.9.9.826.2.1.36.2.1.14

Gauge32

Cisco Firepower ident:IdentRequest:fsmTry managed object property

cfprApIdentIdentRequestId

1.3.6.1.4.1.9.9.826.2.1.36.2.1.15

Gauge32

Cisco Firepower ident:IdentRequest:id managed object property

cfprApIdentIdentRequestRequestSize

1.3.6.1.4.1.9.9.826.2.1.36.2.1.16

Gauge32

Cisco Firepower ident:IdentRequest:requestSize managed object property

cfprApIdentIdentRequestSeqNum

1.3.6.1.4.1.9.9.826.2.1.36.2.1.17

Gauge32

Cisco Firepower ident:IdentRequest:seqNum managed object property

cfprApIdentIdentRequestFsmTable

1.3.6.1.4.1.9.9.826.2.1.36.3

Index: cfprApIdentIdentRequestFsmInstanceId

Cisco Firepower ident:IdentRequestFsm managed object table

cfprApIdentIdentRequestFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.3.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentIdentRequestFsmDn

1.3.6.1.4.1.9.9.826.2.1.36.3.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:IdentRequestFsm:dn managed object property

cfprApIdentIdentRequestFsmRn

1.3.6.1.4.1.9.9.826.2.1.36.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequestFsm:rn managed object property

cfprApIdentIdentRequestFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.36.3.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower ident:IdentRequestFsm:completionTime managed object property

cfprApIdentIdentRequestFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.36.3.1.5

CfprApIdentIdentRequestFsmCurrentFsm0 = nop72 = updateIdent · Integer32

Cisco Firepower ident:IdentRequestFsm:currentFsm managed object property

cfprApIdentIdentRequestFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.36.3.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequestFsm:descr managed object property

cfprApIdentIdentRequestFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.36.3.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower ident:IdentRequestFsm:fsmStatus managed object property

cfprApIdentIdentRequestFsmProgress

1.3.6.1.4.1.9.9.826.2.1.36.3.1.8

Gauge32

Cisco Firepower ident:IdentRequestFsm:progress managed object property

cfprApIdentIdentRequestFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.36.3.1.9

Gauge32

Cisco Firepower ident:IdentRequestFsm:rmtErrCode managed object property

cfprApIdentIdentRequestFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.36.3.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequestFsm:rmtErrDescr managed object property

cfprApIdentIdentRequestFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.36.3.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower ident:IdentRequestFsm:rmtRslt managed object property

cfprApIdentIdentRequestFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.36.4

Index: cfprApIdentIdentRequestFsmStageInstanceId

Cisco Firepower ident:IdentRequestFsmStage managed object table

cfprApIdentIdentRequestFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.4.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentIdentRequestFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.36.4.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:IdentRequestFsmStage:dn managed object property

cfprApIdentIdentRequestFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.36.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequestFsmStage:rn managed object property

cfprApIdentIdentRequestFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.36.4.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequestFsmStage:descr managed object property

cfprApIdentIdentRequestFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.36.4.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower ident:IdentRequestFsmStage:lastUpdateTime managed object property

cfprApIdentIdentRequestFsmStageName

1.3.6.1.4.1.9.9.826.2.1.36.4.1.6

CfprApIdentIdentRequestFsmStageName0 = nop72 = updateIdentBegin73 = updateIdentExecute628 = updateIdentFail629 = updateIdentSuccess · Integer32

Cisco Firepower ident:IdentRequestFsmStage:name managed object property

cfprApIdentIdentRequestFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.36.4.1.7

Gauge32

Cisco Firepower ident:IdentRequestFsmStage:order managed object property

cfprApIdentIdentRequestFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.36.4.1.8

Gauge32

Cisco Firepower ident:IdentRequestFsmStage:retry managed object property

cfprApIdentIdentRequestFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.36.4.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower ident:IdentRequestFsmStage:stageStatus managed object property

cfprApIdentIdentRequestFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.36.5

Index: cfprApIdentIdentRequestFsmTaskInstanceId

Cisco Firepower ident:IdentRequestFsmTask managed object table

cfprApIdentIdentRequestFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.5.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentIdentRequestFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.36.5.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:IdentRequestFsmTask:dn managed object property

cfprApIdentIdentRequestFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.36.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:IdentRequestFsmTask:rn managed object property

cfprApIdentIdentRequestFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.36.5.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower ident:IdentRequestFsmTask:completion managed object property

cfprApIdentIdentRequestFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.36.5.1.5

CfprApFsmFlags · BITS

Cisco Firepower ident:IdentRequestFsmTask:flags managed object property

cfprApIdentIdentRequestFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.36.5.1.6

CfprApIdentIdentRequestFsmTaskItem0 = nop72 = updateIdent · Integer32

Cisco Firepower ident:IdentRequestFsmTask:item managed object property

cfprApIdentIdentRequestFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.36.5.1.7

Gauge32

Cisco Firepower ident:IdentRequestFsmTask:seqId managed object property

cfprApIdentMetaSystemTable

1.3.6.1.4.1.9.9.826.2.1.36.6

Index: cfprApIdentMetaSystemInstanceId

Cisco Firepower ident:MetaSystem managed object table

cfprApIdentMetaSystemInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.6.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentMetaSystemDn

1.3.6.1.4.1.9.9.826.2.1.36.6.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:MetaSystem:dn managed object property

cfprApIdentMetaSystemRn

1.3.6.1.4.1.9.9.826.2.1.36.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystem:rn managed object property

cfprApIdentMetaSystemFsmDescr

1.3.6.1.4.1.9.9.826.2.1.36.6.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystem:fsmDescr managed object property

cfprApIdentMetaSystemFsmPrev

1.3.6.1.4.1.9.9.826.2.1.36.6.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystem:fsmPrev managed object property

cfprApIdentMetaSystemFsmProgr

1.3.6.1.4.1.9.9.826.2.1.36.6.1.6

Gauge32

Cisco Firepower ident:MetaSystem:fsmProgr managed object property

cfprApIdentMetaSystemFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.36.6.1.7

Gauge32

Cisco Firepower ident:MetaSystem:fsmRmtInvErrCode managed object property

cfprApIdentMetaSystemFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.36.6.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystem:fsmRmtInvErrDescr managed object property

cfprApIdentMetaSystemFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.36.6.1.9

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower ident:MetaSystem:fsmRmtInvRslt managed object property

cfprApIdentMetaSystemFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.36.6.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystem:fsmStageDescr managed object property

cfprApIdentMetaSystemFsmStamp

1.3.6.1.4.1.9.9.826.2.1.36.6.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower ident:MetaSystem:fsmStamp managed object property

cfprApIdentMetaSystemFsmStatus

1.3.6.1.4.1.9.9.826.2.1.36.6.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystem:fsmStatus managed object property

cfprApIdentMetaSystemFsmTry

1.3.6.1.4.1.9.9.826.2.1.36.6.1.13

Gauge32

Cisco Firepower ident:MetaSystem:fsmTry managed object property

cfprApIdentMetaSystemGeneration

1.3.6.1.4.1.9.9.826.2.1.36.6.1.14

Gauge32

Cisco Firepower ident:MetaSystem:generation managed object property

cfprApIdentMetaSystemNextReqId

1.3.6.1.4.1.9.9.826.2.1.36.6.1.15

Gauge32

Cisco Firepower ident:MetaSystem:nextReqId managed object property

cfprApIdentMetaSystemSysid

1.3.6.1.4.1.9.9.826.2.1.36.6.1.16

Gauge32

Cisco Firepower ident:MetaSystem:sysid managed object property

cfprApIdentMetaSystemUcscGeneration

1.3.6.1.4.1.9.9.826.2.1.36.6.1.17

Gauge32

Cisco Firepower ident:MetaSystem:ucscGeneration managed object property

cfprApIdentMetaSystemFsmTable

1.3.6.1.4.1.9.9.826.2.1.36.7

Index: cfprApIdentMetaSystemFsmInstanceId

Cisco Firepower ident:MetaSystemFsm managed object table

cfprApIdentMetaSystemFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.7.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentMetaSystemFsmDn

1.3.6.1.4.1.9.9.826.2.1.36.7.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:MetaSystemFsm:dn managed object property

cfprApIdentMetaSystemFsmRn

1.3.6.1.4.1.9.9.826.2.1.36.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystemFsm:rn managed object property

cfprApIdentMetaSystemFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.36.7.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower ident:MetaSystemFsm:completionTime managed object property

cfprApIdentMetaSystemFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.36.7.1.5

CfprApIdentMetaSystemFsmCurrentFsm0 = nop74 = sync77 = ucscUnivSync · Integer32

Cisco Firepower ident:MetaSystemFsm:currentFsm managed object property

cfprApIdentMetaSystemFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.36.7.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystemFsm:descr managed object property

cfprApIdentMetaSystemFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.36.7.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower ident:MetaSystemFsm:fsmStatus managed object property

cfprApIdentMetaSystemFsmProgress

1.3.6.1.4.1.9.9.826.2.1.36.7.1.8

Gauge32

Cisco Firepower ident:MetaSystemFsm:progress managed object property

cfprApIdentMetaSystemFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.36.7.1.9

Gauge32

Cisco Firepower ident:MetaSystemFsm:rmtErrCode managed object property

cfprApIdentMetaSystemFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.36.7.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystemFsm:rmtErrDescr managed object property

cfprApIdentMetaSystemFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.36.7.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower ident:MetaSystemFsm:rmtRslt managed object property

cfprApIdentMetaSystemFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.36.8

Index: cfprApIdentMetaSystemFsmStageInstanceId

Cisco Firepower ident:MetaSystemFsmStage managed object table

cfprApIdentMetaSystemFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.8.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentMetaSystemFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.36.8.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:MetaSystemFsmStage:dn managed object property

cfprApIdentMetaSystemFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.36.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystemFsmStage:rn managed object property

cfprApIdentMetaSystemFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.36.8.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystemFsmStage:descr managed object property

cfprApIdentMetaSystemFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.36.8.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower ident:MetaSystemFsmStage:lastUpdateTime managed object property

cfprApIdentMetaSystemFsmStageName

1.3.6.1.4.1.9.9.826.2.1.36.8.1.6

CfprApIdentMetaSystemFsmStageName0 = nop74 = syncBegin75 = syncPing76 = syncExecute77 = ucscUnivSyncBegin78 = ucscUnivSyncExecute630 = syncFail631 = syncSuccess632 = ucscUnivSyncFail633 = ucscUnivSyncSuccess · Integer32

Cisco Firepower ident:MetaSystemFsmStage:name managed object property

cfprApIdentMetaSystemFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.36.8.1.7

Gauge32

Cisco Firepower ident:MetaSystemFsmStage:order managed object property

cfprApIdentMetaSystemFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.36.8.1.8

Gauge32

Cisco Firepower ident:MetaSystemFsmStage:retry managed object property

cfprApIdentMetaSystemFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.36.8.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower ident:MetaSystemFsmStage:stageStatus managed object property

cfprApIdentMetaSystemFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.36.9

Index: cfprApIdentMetaSystemFsmTaskInstanceId

Cisco Firepower ident:MetaSystemFsmTask managed object table

cfprApIdentMetaSystemFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.9.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentMetaSystemFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.36.9.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:MetaSystemFsmTask:dn managed object property

cfprApIdentMetaSystemFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.36.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaSystemFsmTask:rn managed object property

cfprApIdentMetaSystemFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.36.9.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower ident:MetaSystemFsmTask:completion managed object property

cfprApIdentMetaSystemFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.36.9.1.5

CfprApFsmFlags · BITS

Cisco Firepower ident:MetaSystemFsmTask:flags managed object property

cfprApIdentMetaSystemFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.36.9.1.6

CfprApIdentMetaSystemFsmTaskItem0 = nop74 = sync77 = ucscUnivSync · Integer32

Cisco Firepower ident:MetaSystemFsmTask:item managed object property

cfprApIdentMetaSystemFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.36.9.1.7

Gauge32

Cisco Firepower ident:MetaSystemFsmTask:seqId managed object property

cfprApIdentMetaVerseTable

1.3.6.1.4.1.9.9.826.2.1.36.10

Index: cfprApIdentMetaVerseInstanceId

Cisco Firepower ident:MetaVerse managed object table

cfprApIdentMetaVerseInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.10.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentMetaVerseDn

1.3.6.1.4.1.9.9.826.2.1.36.10.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:MetaVerse:dn managed object property

cfprApIdentMetaVerseRn

1.3.6.1.4.1.9.9.826.2.1.36.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:MetaVerse:rn managed object property

cfprApIdentRequestEpTable

1.3.6.1.4.1.9.9.826.2.1.36.11

Index: cfprApIdentRequestEpInstanceId

Cisco Firepower ident:RequestEp managed object table

cfprApIdentRequestEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.11.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentRequestEpDn

1.3.6.1.4.1.9.9.826.2.1.36.11.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:RequestEp:dn managed object property

cfprApIdentRequestEpRn

1.3.6.1.4.1.9.9.826.2.1.36.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:RequestEp:rn managed object property

cfprApIdentRequestEpReqDn

1.3.6.1.4.1.9.9.826.2.1.36.11.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:RequestEp:reqDn managed object property

cfprApIdentRequestEpReqId

1.3.6.1.4.1.9.9.826.2.1.36.11.1.5

Gauge32

Cisco Firepower ident:RequestEp:reqId managed object property

cfprApIdentSysInfoTable

1.3.6.1.4.1.9.9.826.2.1.36.12

Index: cfprApIdentSysInfoInstanceId

Cisco Firepower ident:SysInfo managed object table

cfprApIdentSysInfoInstanceId

1.3.6.1.4.1.9.9.826.2.1.36.12.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApIdentSysInfoDn

1.3.6.1.4.1.9.9.826.2.1.36.12.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower ident:SysInfo:dn managed object property

cfprApIdentSysInfoRn

1.3.6.1.4.1.9.9.826.2.1.36.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower ident:SysInfo:rn managed object property

cfprApIdentSysInfoGeneration

1.3.6.1.4.1.9.9.826.2.1.36.12.1.4

Gauge32

Cisco Firepower ident:SysInfo:generation managed object property

cfprApIdentSysInfoIsFirstSync

1.3.6.1.4.1.9.9.826.2.1.36.12.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower ident:SysInfo:isFirstSync managed object property

cfprApIdentSysInfoIsSync

1.3.6.1.4.1.9.9.826.2.1.36.12.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower ident:SysInfo:isSync managed object property

cfprApIdentSysInfoIsSyncAllowed

1.3.6.1.4.1.9.9.826.2.1.36.12.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower ident:SysInfo:isSyncAllowed managed object property

cfprApIdentSysInfoUcscGeneration

1.3.6.1.4.1.9.9.826.2.1.36.12.1.8

Gauge32

Cisco Firepower ident:SysInfo:ucscGeneration managed object property

↑ To TOC