CISCO-FIREPOWER-AP-POWER-MIB

2023-01-25

MIB representation of the Cisco Firepower POWER management information model package

Download CISCO-FIREPOWER-AP-POWER-MIB.txt Open CISCO-FIREPOWER-AP-POWER-MIB.txt in a new tab

TABLES (14)

Tables (14)

NameOID
cfprApPowerBudgetTable1.3.6.1.4.1.9.9.826.2.1.64.1
cfprApPowerChassisMemberTable1.3.6.1.4.1.9.9.826.2.1.64.2
cfprApPowerEpTable1.3.6.1.4.1.9.9.826.2.1.64.3
cfprApPowerGroupTable1.3.6.1.4.1.9.9.826.2.1.64.4
cfprApPowerGroupAdditionPolicyTable1.3.6.1.4.1.9.9.826.2.1.64.5
cfprApPowerGroupQualTable1.3.6.1.4.1.9.9.826.2.1.64.6
cfprApPowerGroupStatsTable1.3.6.1.4.1.9.9.826.2.1.64.7
cfprApPowerGroupStatsHistTable1.3.6.1.4.1.9.9.826.2.1.64.8
cfprApPowerMgmtPolicyTable1.3.6.1.4.1.9.9.826.2.1.64.9
cfprApPowerPlacementTable1.3.6.1.4.1.9.9.826.2.1.64.10
cfprApPowerPolicyTable1.3.6.1.4.1.9.9.826.2.1.64.11
cfprApPowerPrioWghtTable1.3.6.1.4.1.9.9.826.2.1.64.12
cfprApPowerProfiledPowerTable1.3.6.1.4.1.9.9.826.2.1.64.13
cfprApPowerRackUnitMemberTable1.3.6.1.4.1.9.9.826.2.1.64.14

END OF TOC

Table details

cfprApPowerBudgetTable

1.3.6.1.4.1.9.9.826.2.1.64.1

Index: cfprApPowerBudgetInstanceId

Cisco Firepower power:Budget managed object table

cfprApPowerBudgetInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.1.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerBudgetDn

1.3.6.1.4.1.9.9.826.2.1.64.1.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Budget:dn managed object property

cfprApPowerBudgetRn

1.3.6.1.4.1.9.9.826.2.1.64.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Budget:rn managed object property

cfprApPowerBudgetAdminCommitted

1.3.6.1.4.1.9.9.826.2.1.64.1.1.4

Gauge32

Cisco Firepower power:Budget:adminCommitted managed object property

cfprApPowerBudgetAdminFPLockState

1.3.6.1.4.1.9.9.826.2.1.64.1.1.5

CfprApPowerLockState0 = unknown1 = locked2 = unlocked · Integer32

Cisco Firepower power:Budget:adminFPLockState managed object property

cfprApPowerBudgetAdminPeak

1.3.6.1.4.1.9.9.826.2.1.64.1.1.6

Gauge32

Cisco Firepower power:Budget:adminPeak managed object property

cfprApPowerBudgetAdminPeakNew

1.3.6.1.4.1.9.9.826.2.1.64.1.1.7

Gauge32

Cisco Firepower power:Budget:adminPeakNew managed object property

cfprApPowerBudgetBootPower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.8

Gauge32

Cisco Firepower power:Budget:bootPower managed object property

cfprApPowerBudgetCapAction

1.3.6.1.4.1.9.9.826.2.1.64.1.1.9

CfprApPowerCapAction0 = nothing1 = clockDown2 = throttled · Integer32

Cisco Firepower power:Budget:capAction managed object property

cfprApPowerBudgetCatalogPower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.10

Gauge32

Cisco Firepower power:Budget:catalogPower managed object property

cfprApPowerBudgetChRsrvdPower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.11

Gauge32

Cisco Firepower power:Budget:chRsrvdPower managed object property

cfprApPowerBudgetCurrentPower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.12

Gauge32

Cisco Firepower power:Budget:currentPower managed object property

cfprApPowerBudgetDynRealloc

1.3.6.1.4.1.9.9.826.2.1.64.1.1.13

CfprApPowerReallocation0 = chassis1 = none · Integer32

Cisco Firepower power:Budget:dynRealloc managed object property

cfprApPowerBudgetGroupName

1.3.6.1.4.1.9.9.826.2.1.64.1.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Budget:groupName managed object property

cfprApPowerBudgetIdlePower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.15

Gauge32

Cisco Firepower power:Budget:idlePower managed object property

cfprApPowerBudgetMaxPower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.16

Gauge32

Cisco Firepower power:Budget:maxPower managed object property

cfprApPowerBudgetMinPower

1.3.6.1.4.1.9.9.826.2.1.64.1.1.17

Gauge32

Cisco Firepower power:Budget:minPower managed object property

cfprApPowerBudgetOperCommitted

1.3.6.1.4.1.9.9.826.2.1.64.1.1.18

Gauge32

Cisco Firepower power:Budget:operCommitted managed object property

cfprApPowerBudgetOperFPLockState

1.3.6.1.4.1.9.9.826.2.1.64.1.1.19

CfprApPowerLockState0 = unknown1 = locked2 = unlocked · Integer32

Cisco Firepower power:Budget:operFPLockState managed object property

cfprApPowerBudgetOperMin

1.3.6.1.4.1.9.9.826.2.1.64.1.1.20

Gauge32

Cisco Firepower power:Budget:operMin managed object property

cfprApPowerBudgetOperPeak

1.3.6.1.4.1.9.9.826.2.1.64.1.1.21

Gauge32

Cisco Firepower power:Budget:operPeak managed object property

cfprApPowerBudgetOperProfMethod

1.3.6.1.4.1.9.9.826.2.1.64.1.1.22

CfprApPowerProfilingMethod0 = unknown1 = default2 = static3 = pnuos4 = nodemgr · Integer32

Cisco Firepower power:Budget:operProfMethod managed object property

cfprApPowerBudgetOperState

1.3.6.1.4.1.9.9.826.2.1.64.1.1.23

CfprApPowerOperState0 = notCapped1 = budgeting2 = budgeted3 = deploying4 = deployed5 = discoveryRetry6 = nonCompliant7 = firmwareMismatch8 = discoveryBudgeted9 = unbudgeted · Integer32

Cisco Firepower power:Budget:operState managed object property

cfprApPowerBudgetPrio

1.3.6.1.4.1.9.9.826.2.1.64.1.1.24

Gauge32

Cisco Firepower power:Budget:prio managed object property

cfprApPowerBudgetProfMethod

1.3.6.1.4.1.9.9.826.2.1.64.1.1.25

CfprApPowerProfilingMethod0 = unknown1 = default2 = static3 = pnuos4 = nodemgr · Integer32

Cisco Firepower power:Budget:profMethod managed object property

cfprApPowerBudgetProfiling

1.3.6.1.4.1.9.9.826.2.1.64.1.1.26

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:Budget:profiling managed object property

cfprApPowerBudgetPsuCapacity

1.3.6.1.4.1.9.9.826.2.1.64.1.1.27

Gauge32

Cisco Firepower power:Budget:psuCapacity managed object property

cfprApPowerBudgetPsuLineMode

1.3.6.1.4.1.9.9.826.2.1.64.1.1.28

CfprApPowerPsuLineMode0 = unknown1 = undetermined2 = highLine3 = lowLine4 = mixedLine5 = lowerLine · Integer32

Cisco Firepower power:Budget:psuLineMode managed object property

cfprApPowerBudgetPsuState

1.3.6.1.4.1.9.9.826.2.1.64.1.1.29

CfprApPowerPsuState0 = ok1 = insufficient · Integer32

Cisco Firepower power:Budget:psuState managed object property

cfprApPowerBudgetScaledWt

1.3.6.1.4.1.9.9.826.2.1.64.1.1.30

Gauge32

Cisco Firepower power:Budget:scaledWt managed object property

cfprApPowerBudgetStyle

1.3.6.1.4.1.9.9.826.2.1.64.1.1.31

CfprApPowerMgmtStyle0 = manualPerBlade1 = intelligentPolicyDriven · Integer32

Cisco Firepower power:Budget:style managed object property

cfprApPowerBudgetUpdateTime

1.3.6.1.4.1.9.9.826.2.1.64.1.1.32

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower power:Budget:updateTime managed object property

cfprApPowerBudgetWeight

1.3.6.1.4.1.9.9.826.2.1.64.1.1.33

Gauge32

Cisco Firepower power:Budget:weight managed object property

cfprApPowerChassisMemberTable

1.3.6.1.4.1.9.9.826.2.1.64.2

Index: cfprApPowerChassisMemberInstanceId

Cisco Firepower power:ChassisMember managed object table

cfprApPowerChassisMemberInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.2.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerChassisMemberDn

1.3.6.1.4.1.9.9.826.2.1.64.2.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:ChassisMember:dn managed object property

cfprApPowerChassisMemberRn

1.3.6.1.4.1.9.9.826.2.1.64.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:ChassisMember:rn managed object property

cfprApPowerChassisMemberId

1.3.6.1.4.1.9.9.826.2.1.64.2.1.4

Gauge32

Cisco Firepower power:ChassisMember:id managed object property

cfprApPowerChassisMemberOperState

1.3.6.1.4.1.9.9.826.2.1.64.2.1.5

CfprApPowerMemberState0 = uninitialized1 = capOk2 = fwMismatch3 = psuInsufficient4 = psuRedundancyFailed5 = capInsufficient · Integer32

Cisco Firepower power:ChassisMember:operState managed object property

cfprApPowerEpTable

1.3.6.1.4.1.9.9.826.2.1.64.3

Index: cfprApPowerEpInstanceId

Cisco Firepower power:Ep managed object table

cfprApPowerEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.3.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerEpDn

1.3.6.1.4.1.9.9.826.2.1.64.3.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Ep:dn managed object property

cfprApPowerEpRn

1.3.6.1.4.1.9.9.826.2.1.64.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Ep:rn managed object property

cfprApPowerGroupTable

1.3.6.1.4.1.9.9.826.2.1.64.4

Index: cfprApPowerGroupInstanceId

Cisco Firepower power:Group managed object table

cfprApPowerGroupInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.4.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerGroupDn

1.3.6.1.4.1.9.9.826.2.1.64.4.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Group:dn managed object property

cfprApPowerGroupRn

1.3.6.1.4.1.9.9.826.2.1.64.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:rn managed object property

cfprApPowerGroupAdminCommitted

1.3.6.1.4.1.9.9.826.2.1.64.4.1.4

Gauge32

Cisco Firepower power:Group:adminCommitted managed object property

cfprApPowerGroupAdminPeak

1.3.6.1.4.1.9.9.826.2.1.64.4.1.5

Gauge32

Cisco Firepower power:Group:adminPeak managed object property

cfprApPowerGroupCurReqPower

1.3.6.1.4.1.9.9.826.2.1.64.4.1.6

Gauge32

Cisco Firepower power:Group:curReqPower managed object property

cfprApPowerGroupCurrentPower

1.3.6.1.4.1.9.9.826.2.1.64.4.1.7

Gauge32

Cisco Firepower power:Group:currentPower managed object property

cfprApPowerGroupDescr

1.3.6.1.4.1.9.9.826.2.1.64.4.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:descr managed object property

cfprApPowerGroupFltAggr

1.3.6.1.4.1.9.9.826.2.1.64.4.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower power:Group:fltAggr managed object property

cfprApPowerGroupIntId

1.3.6.1.4.1.9.9.826.2.1.64.4.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:intId managed object property

cfprApPowerGroupMinReqPower

1.3.6.1.4.1.9.9.826.2.1.64.4.1.11

Gauge32

Cisco Firepower power:Group:minReqPower managed object property

cfprApPowerGroupName

1.3.6.1.4.1.9.9.826.2.1.64.4.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:name managed object property

cfprApPowerGroupOperCommitted

1.3.6.1.4.1.9.9.826.2.1.64.4.1.13

Gauge32

Cisco Firepower power:Group:operCommitted managed object property

cfprApPowerGroupOperPeak

1.3.6.1.4.1.9.9.826.2.1.64.4.1.14

Gauge32

Cisco Firepower power:Group:operPeak managed object property

cfprApPowerGroupOperState

1.3.6.1.4.1.9.9.826.2.1.64.4.1.15

CfprApPowerGroupState · BITS

Cisco Firepower power:Group:operState managed object property

cfprApPowerGroupPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.64.4.1.16

Gauge32

Cisco Firepower power:Group:policyLevel managed object property

cfprApPowerGroupPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.64.4.1.17

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:Group:policyOwner managed object property

cfprApPowerGroupQualifier

1.3.6.1.4.1.9.9.826.2.1.64.4.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:qualifier managed object property

cfprApPowerGroupRealloc

1.3.6.1.4.1.9.9.826.2.1.64.4.1.19

CfprApPowerReallocation0 = chassis1 = none · Integer32

Cisco Firepower power:Group:realloc managed object property

cfprApPowerGroupAdditionPolicyTable

1.3.6.1.4.1.9.9.826.2.1.64.5

Index: cfprApPowerGroupAdditionPolicyInstanceId

Cisco Firepower power:GroupAdditionPolicy managed object table

cfprApPowerGroupAdditionPolicyInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.5.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerGroupAdditionPolicyDn

1.3.6.1.4.1.9.9.826.2.1.64.5.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupAdditionPolicy:dn managed object property

cfprApPowerGroupAdditionPolicyRn

1.3.6.1.4.1.9.9.826.2.1.64.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:rn managed object property

cfprApPowerGroupAdditionPolicyAction

1.3.6.1.4.1.9.9.826.2.1.64.5.1.4

CfprApPowerChThrAction0 = nothing1 = throttleBladeDisc2 = stopBladeDisc · Integer32

Cisco Firepower power:GroupAdditionPolicy:action managed object property

cfprApPowerGroupAdditionPolicyDescr

1.3.6.1.4.1.9.9.826.2.1.64.5.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:descr managed object property

cfprApPowerGroupAdditionPolicyIntId

1.3.6.1.4.1.9.9.826.2.1.64.5.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:intId managed object property

cfprApPowerGroupAdditionPolicyName

1.3.6.1.4.1.9.9.826.2.1.64.5.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:name managed object property

cfprApPowerGroupAdditionPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.64.5.1.8

Gauge32

Cisco Firepower power:GroupAdditionPolicy:policyLevel managed object property

cfprApPowerGroupAdditionPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.64.5.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:GroupAdditionPolicy:policyOwner managed object property

cfprApPowerGroupQualTable

1.3.6.1.4.1.9.9.826.2.1.64.6

Index: cfprApPowerGroupQualInstanceId

Cisco Firepower power:GroupQual managed object table

cfprApPowerGroupQualInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.6.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerGroupQualDn

1.3.6.1.4.1.9.9.826.2.1.64.6.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupQual:dn managed object property

cfprApPowerGroupQualRn

1.3.6.1.4.1.9.9.826.2.1.64.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupQual:rn managed object property

cfprApPowerGroupQualGroupName

1.3.6.1.4.1.9.9.826.2.1.64.6.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupQual:groupName managed object property

cfprApPowerGroupStatsTable

1.3.6.1.4.1.9.9.826.2.1.64.7

Index: cfprApPowerGroupStatsInstanceId

Cisco Firepower power:GroupStats managed object table

cfprApPowerGroupStatsInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.7.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerGroupStatsDn

1.3.6.1.4.1.9.9.826.2.1.64.7.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupStats:dn managed object property

cfprApPowerGroupStatsRn

1.3.6.1.4.1.9.9.826.2.1.64.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupStats:rn managed object property

cfprApPowerGroupStatsIntervals

1.3.6.1.4.1.9.9.826.2.1.64.7.1.4

Gauge32

Cisco Firepower power:GroupStats:intervals managed object property

cfprApPowerGroupStatsPower

1.3.6.1.4.1.9.9.826.2.1.64.7.1.5

INTEGER · Integer32

Cisco Firepower power:GroupStats:power managed object property

cfprApPowerGroupStatsPowerAvg

1.3.6.1.4.1.9.9.826.2.1.64.7.1.6

INTEGER · Integer32

Cisco Firepower power:GroupStats:powerAvg managed object property

cfprApPowerGroupStatsPowerMax

1.3.6.1.4.1.9.9.826.2.1.64.7.1.7

INTEGER · Integer32

Cisco Firepower power:GroupStats:powerMax managed object property

cfprApPowerGroupStatsPowerMin

1.3.6.1.4.1.9.9.826.2.1.64.7.1.8

INTEGER · Integer32

Cisco Firepower power:GroupStats:powerMin managed object property

cfprApPowerGroupStatsSuspect

1.3.6.1.4.1.9.9.826.2.1.64.7.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:GroupStats:suspect managed object property

cfprApPowerGroupStatsThresholded

1.3.6.1.4.1.9.9.826.2.1.64.7.1.10

CfprApPowerGroupStatsThresholded · BITS

Cisco Firepower power:GroupStats:thresholded managed object property

cfprApPowerGroupStatsTimeCollected

1.3.6.1.4.1.9.9.826.2.1.64.7.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower power:GroupStats:timeCollected managed object property

cfprApPowerGroupStatsUpdate

1.3.6.1.4.1.9.9.826.2.1.64.7.1.12

Gauge32

Cisco Firepower power:GroupStats:update managed object property

cfprApPowerGroupStatsHistTable

1.3.6.1.4.1.9.9.826.2.1.64.8

Index: cfprApPowerGroupStatsHistInstanceId

Cisco Firepower power:GroupStatsHist managed object table

cfprApPowerGroupStatsHistInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.8.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerGroupStatsHistDn

1.3.6.1.4.1.9.9.826.2.1.64.8.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupStatsHist:dn managed object property

cfprApPowerGroupStatsHistRn

1.3.6.1.4.1.9.9.826.2.1.64.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupStatsHist:rn managed object property

cfprApPowerGroupStatsHistId

1.3.6.1.4.1.9.9.826.2.1.64.8.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower power:GroupStatsHist:id managed object property

cfprApPowerGroupStatsHistMostRecent

1.3.6.1.4.1.9.9.826.2.1.64.8.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:GroupStatsHist:mostRecent managed object property

cfprApPowerGroupStatsHistPower

1.3.6.1.4.1.9.9.826.2.1.64.8.1.6

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:power managed object property

cfprApPowerGroupStatsHistPowerAvg

1.3.6.1.4.1.9.9.826.2.1.64.8.1.7

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:powerAvg managed object property

cfprApPowerGroupStatsHistPowerMax

1.3.6.1.4.1.9.9.826.2.1.64.8.1.8

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:powerMax managed object property

cfprApPowerGroupStatsHistPowerMin

1.3.6.1.4.1.9.9.826.2.1.64.8.1.9

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:powerMin managed object property

cfprApPowerGroupStatsHistSuspect

1.3.6.1.4.1.9.9.826.2.1.64.8.1.10

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:GroupStatsHist:suspect managed object property

cfprApPowerGroupStatsHistThresholded

1.3.6.1.4.1.9.9.826.2.1.64.8.1.11

CfprApPowerGroupStatsHistThresholded · BITS

Cisco Firepower power:GroupStatsHist:thresholded managed object property

cfprApPowerGroupStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.2.1.64.8.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower power:GroupStatsHist:timeCollected managed object property

cfprApPowerMgmtPolicyTable

1.3.6.1.4.1.9.9.826.2.1.64.9

Index: cfprApPowerMgmtPolicyInstanceId

Cisco Firepower power:MgmtPolicy managed object table

cfprApPowerMgmtPolicyInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.9.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerMgmtPolicyDn

1.3.6.1.4.1.9.9.826.2.1.64.9.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:MgmtPolicy:dn managed object property

cfprApPowerMgmtPolicyRn

1.3.6.1.4.1.9.9.826.2.1.64.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:rn managed object property

cfprApPowerMgmtPolicyDescr

1.3.6.1.4.1.9.9.826.2.1.64.9.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:descr managed object property

cfprApPowerMgmtPolicyIntId

1.3.6.1.4.1.9.9.826.2.1.64.9.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:intId managed object property

cfprApPowerMgmtPolicyName

1.3.6.1.4.1.9.9.826.2.1.64.9.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:name managed object property

cfprApPowerMgmtPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.64.9.1.7

Gauge32

Cisco Firepower power:MgmtPolicy:policyLevel managed object property

cfprApPowerMgmtPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.64.9.1.8

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:MgmtPolicy:policyOwner managed object property

cfprApPowerMgmtPolicyProfiling

1.3.6.1.4.1.9.9.826.2.1.64.9.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:MgmtPolicy:profiling managed object property

cfprApPowerMgmtPolicyStyle

1.3.6.1.4.1.9.9.826.2.1.64.9.1.10

CfprApPowerMgmtStyle0 = manualPerBlade1 = intelligentPolicyDriven · Integer32

Cisco Firepower power:MgmtPolicy:style managed object property

cfprApPowerPlacementTable

1.3.6.1.4.1.9.9.826.2.1.64.10

Index: cfprApPowerPlacementInstanceId

Cisco Firepower power:Placement managed object table

cfprApPowerPlacementInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.10.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerPlacementDn

1.3.6.1.4.1.9.9.826.2.1.64.10.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Placement:dn managed object property

cfprApPowerPlacementRn

1.3.6.1.4.1.9.9.826.2.1.64.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:rn managed object property

cfprApPowerPlacementDescr

1.3.6.1.4.1.9.9.826.2.1.64.10.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:descr managed object property

cfprApPowerPlacementIntId

1.3.6.1.4.1.9.9.826.2.1.64.10.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:intId managed object property

cfprApPowerPlacementName

1.3.6.1.4.1.9.9.826.2.1.64.10.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:name managed object property

cfprApPowerPlacementPeerReqConflict

1.3.6.1.4.1.9.9.826.2.1.64.10.1.7

CfprApPowerReqConflict0 = ignore1 = failPlacement · Integer32

Cisco Firepower power:Placement:peerReqConflict managed object property

cfprApPowerPlacementPgName

1.3.6.1.4.1.9.9.826.2.1.64.10.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:pgName managed object property

cfprApPowerPlacementPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.64.10.1.9

Gauge32

Cisco Firepower power:Placement:policyLevel managed object property

cfprApPowerPlacementPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.64.10.1.10

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:Placement:policyOwner managed object property

cfprApPowerPlacementPrioShare

1.3.6.1.4.1.9.9.826.2.1.64.10.1.11

CfprApPowerPrioritySharing0 = noPreference1 = highestPrioInChassis2 = highestPrioInPowerGroup · Integer32

Cisco Firepower power:Placement:prioShare managed object property

cfprApPowerPlacementSelfReqConflict

1.3.6.1.4.1.9.9.826.2.1.64.10.1.12

CfprApPowerReqConflict0 = ignore1 = failPlacement · Integer32

Cisco Firepower power:Placement:selfReqConflict managed object property

cfprApPowerPolicyTable

1.3.6.1.4.1.9.9.826.2.1.64.11

Index: cfprApPowerPolicyInstanceId

Cisco Firepower power:Policy managed object table

cfprApPowerPolicyInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.11.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerPolicyDn

1.3.6.1.4.1.9.9.826.2.1.64.11.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Policy:dn managed object property

cfprApPowerPolicyRn

1.3.6.1.4.1.9.9.826.2.1.64.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:rn managed object property

cfprApPowerPolicyDescr

1.3.6.1.4.1.9.9.826.2.1.64.11.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:descr managed object property

cfprApPowerPolicyIntId

1.3.6.1.4.1.9.9.826.2.1.64.11.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:intId managed object property

cfprApPowerPolicyName

1.3.6.1.4.1.9.9.826.2.1.64.11.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:name managed object property

cfprApPowerPolicyOperPrio

1.3.6.1.4.1.9.9.826.2.1.64.11.1.7

Gauge32

Cisco Firepower power:Policy:operPrio managed object property

cfprApPowerPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.64.11.1.8

Gauge32

Cisco Firepower power:Policy:policyLevel managed object property

cfprApPowerPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.64.11.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:Policy:policyOwner managed object property

cfprApPowerPolicyPrio

1.3.6.1.4.1.9.9.826.2.1.64.11.1.10

Gauge32

Cisco Firepower power:Policy:prio managed object property

cfprApPowerPrioWghtTable

1.3.6.1.4.1.9.9.826.2.1.64.12

Index: cfprApPowerPrioWghtInstanceId

Cisco Firepower power:PrioWght managed object table

cfprApPowerPrioWghtInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.12.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerPrioWghtDn

1.3.6.1.4.1.9.9.826.2.1.64.12.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:PrioWght:dn managed object property

cfprApPowerPrioWghtRn

1.3.6.1.4.1.9.9.826.2.1.64.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:PrioWght:rn managed object property

cfprApPowerPrioWghtPrio

1.3.6.1.4.1.9.9.826.2.1.64.12.1.4

Gauge32

Cisco Firepower power:PrioWght:prio managed object property

cfprApPowerPrioWghtWeight

1.3.6.1.4.1.9.9.826.2.1.64.12.1.5

Gauge32

Cisco Firepower power:PrioWght:weight managed object property

cfprApPowerProfiledPowerTable

1.3.6.1.4.1.9.9.826.2.1.64.13

Index: cfprApPowerProfiledPowerInstanceId

Cisco Firepower power:ProfiledPower managed object table

cfprApPowerProfiledPowerInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.13.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerProfiledPowerDn

1.3.6.1.4.1.9.9.826.2.1.64.13.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:ProfiledPower:dn managed object property

cfprApPowerProfiledPowerRn

1.3.6.1.4.1.9.9.826.2.1.64.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:ProfiledPower:rn managed object property

cfprApPowerProfiledPowerAbsMinPostPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.4

Gauge32

Cisco Firepower power:ProfiledPower:absMinPostPower managed object property

cfprApPowerProfiledPowerMaxAppPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.5

Gauge32

Cisco Firepower power:ProfiledPower:maxAppPower managed object property

cfprApPowerProfiledPowerMaxPostPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.6

Gauge32

Cisco Firepower power:ProfiledPower:maxPostPower managed object property

cfprApPowerProfiledPowerMinAppPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.7

Gauge32

Cisco Firepower power:ProfiledPower:minAppPower managed object property

cfprApPowerProfiledPowerMinNormPostPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.8

Gauge32

Cisco Firepower power:ProfiledPower:minNormPostPower managed object property

cfprApPowerProfiledPowerMinPostPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.9

Gauge32

Cisco Firepower power:ProfiledPower:minPostPower managed object property

cfprApPowerProfiledPowerPreDiscoveryPower

1.3.6.1.4.1.9.9.826.2.1.64.13.1.10

Gauge32

Cisco Firepower power:ProfiledPower:preDiscoveryPower managed object property

cfprApPowerProfiledPowerProfileRunTime

1.3.6.1.4.1.9.9.826.2.1.64.13.1.11

Gauge32

Cisco Firepower power:ProfiledPower:profileRunTime managed object property

cfprApPowerProfiledPowerProfiledBoot

1.3.6.1.4.1.9.9.826.2.1.64.13.1.12

Gauge32

Cisco Firepower power:ProfiledPower:profiledBoot managed object property

cfprApPowerProfiledPowerProfiledMax

1.3.6.1.4.1.9.9.826.2.1.64.13.1.13

Gauge32

Cisco Firepower power:ProfiledPower:profiledMax managed object property

cfprApPowerProfiledPowerProfiledMin

1.3.6.1.4.1.9.9.826.2.1.64.13.1.14

Gauge32

Cisco Firepower power:ProfiledPower:profiledMin managed object property

cfprApPowerProfiledPowerSkipProfiling

1.3.6.1.4.1.9.9.826.2.1.64.13.1.15

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:ProfiledPower:skipProfiling managed object property

cfprApPowerRackUnitMemberTable

1.3.6.1.4.1.9.9.826.2.1.64.14

Index: cfprApPowerRackUnitMemberInstanceId

Cisco Firepower power:RackUnitMember managed object table

cfprApPowerRackUnitMemberInstanceId

1.3.6.1.4.1.9.9.826.2.1.64.14.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApPowerRackUnitMemberDn

1.3.6.1.4.1.9.9.826.2.1.64.14.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:RackUnitMember:dn managed object property

cfprApPowerRackUnitMemberRn

1.3.6.1.4.1.9.9.826.2.1.64.14.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:RackUnitMember:rn managed object property

cfprApPowerRackUnitMemberId

1.3.6.1.4.1.9.9.826.2.1.64.14.1.4

Gauge32

Cisco Firepower power:RackUnitMember:id managed object property

cfprApPowerRackUnitMemberOperState

1.3.6.1.4.1.9.9.826.2.1.64.14.1.5

CfprApPowerMemberState0 = uninitialized1 = capOk2 = fwMismatch3 = psuInsufficient4 = psuRedundancyFailed5 = capInsufficient · Integer32

Cisco Firepower power:RackUnitMember:operState managed object property

↑ To TOC