EZ5 MIB Catalog

CISCO-FIREPOWER-AP-STATS-MIB

2023-01-25

MIB representation of the Cisco Firepower STATS management information model package

Download CISCO-FIREPOWER-AP-STATS-MIB.txt Open CISCO-FIREPOWER-AP-STATS-MIB.txt in a new tab

TABLES (13)

Tables (13)

NameOID
cfprApStatsCollectionPolicyTable1.3.6.1.4.1.9.9.826.2.1.73.1
cfprApStatsCollectionPolicyFsmTable1.3.6.1.4.1.9.9.826.2.1.73.2
cfprApStatsCollectionPolicyFsmStageTable1.3.6.1.4.1.9.9.826.2.1.73.3
cfprApStatsCollectionPolicyFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.73.4
cfprApStatsHolderTable1.3.6.1.4.1.9.9.826.2.1.73.5
cfprApStatsThr32DefinitionTable1.3.6.1.4.1.9.9.826.2.1.73.6
cfprApStatsThr32ValueTable1.3.6.1.4.1.9.9.826.2.1.73.7
cfprApStatsThr64DefinitionTable1.3.6.1.4.1.9.9.826.2.1.73.8
cfprApStatsThr64ValueTable1.3.6.1.4.1.9.9.826.2.1.73.9
cfprApStatsThrFloatDefinitionTable1.3.6.1.4.1.9.9.826.2.1.73.10
cfprApStatsThrFloatValueTable1.3.6.1.4.1.9.9.826.2.1.73.11
cfprApStatsThresholdClassTable1.3.6.1.4.1.9.9.826.2.1.73.12
cfprApStatsThresholdPolicyTable1.3.6.1.4.1.9.9.826.2.1.73.13

END OF TOC

Table details

cfprApStatsCollectionPolicyTable

1.3.6.1.4.1.9.9.826.2.1.73.1

Index: cfprApStatsCollectionPolicyInstanceId

Cisco Firepower stats:CollectionPolicy managed object table

cfprApStatsCollectionPolicyInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.1.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsCollectionPolicyDn

1.3.6.1.4.1.9.9.826.2.1.73.1.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:CollectionPolicy:dn managed object property

cfprApStatsCollectionPolicyRn

1.3.6.1.4.1.9.9.826.2.1.73.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicy:rn managed object property

cfprApStatsCollectionPolicyCollectionInterval

1.3.6.1.4.1.9.9.826.2.1.73.1.1.4

CfprApStatsCollectionInterval30 = n30seconds60 = n1minute120 = n2minutes300 = n5minutes · Integer32

Cisco Firepower stats:CollectionPolicy:collectionInterval managed object property

cfprApStatsCollectionPolicyFsmDescr

1.3.6.1.4.1.9.9.826.2.1.73.1.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicy:fsmDescr managed object property

cfprApStatsCollectionPolicyFsmPrev

1.3.6.1.4.1.9.9.826.2.1.73.1.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicy:fsmPrev managed object property

cfprApStatsCollectionPolicyFsmProgr

1.3.6.1.4.1.9.9.826.2.1.73.1.1.7

Gauge32

Cisco Firepower stats:CollectionPolicy:fsmProgr managed object property

cfprApStatsCollectionPolicyFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.73.1.1.8

Gauge32

Cisco Firepower stats:CollectionPolicy:fsmRmtInvErrCode managed object property

cfprApStatsCollectionPolicyFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.73.1.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicy:fsmRmtInvErrDescr managed object property

cfprApStatsCollectionPolicyFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.73.1.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower stats:CollectionPolicy:fsmRmtInvRslt managed object property

cfprApStatsCollectionPolicyFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.73.1.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicy:fsmStageDescr managed object property

cfprApStatsCollectionPolicyFsmStamp

1.3.6.1.4.1.9.9.826.2.1.73.1.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower stats:CollectionPolicy:fsmStamp managed object property

cfprApStatsCollectionPolicyFsmStatus

1.3.6.1.4.1.9.9.826.2.1.73.1.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicy:fsmStatus managed object property

cfprApStatsCollectionPolicyFsmTry

1.3.6.1.4.1.9.9.826.2.1.73.1.1.14

Gauge32

Cisco Firepower stats:CollectionPolicy:fsmTry managed object property

cfprApStatsCollectionPolicyId

1.3.6.1.4.1.9.9.826.2.1.73.1.1.15

Gauge32

Cisco Firepower stats:CollectionPolicy:id managed object property

cfprApStatsCollectionPolicyName

1.3.6.1.4.1.9.9.826.2.1.73.1.1.16

CfprApStatsCollectionDomain0 = unknown1 = chassis2 = server3 = port4 = fex · Integer32

Cisco Firepower stats:CollectionPolicy:name managed object property

cfprApStatsCollectionPolicyReportingInterval

1.3.6.1.4.1.9.9.826.2.1.73.1.1.17

CfprApStatsReportingInterval120 = n2minutes900 = n15minutes1800 = n30minutes3600 = n60minutes7200 = n2hours14400 = n4hours28800 = n8hours · Integer32

Cisco Firepower stats:CollectionPolicy:reportingInterval managed object property

cfprApStatsCollectionPolicyFsmTable

1.3.6.1.4.1.9.9.826.2.1.73.2

Index: cfprApStatsCollectionPolicyFsmInstanceId

Cisco Firepower stats:CollectionPolicyFsm managed object table

cfprApStatsCollectionPolicyFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.2.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsCollectionPolicyFsmDn

1.3.6.1.4.1.9.9.826.2.1.73.2.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:CollectionPolicyFsm:dn managed object property

cfprApStatsCollectionPolicyFsmRn

1.3.6.1.4.1.9.9.826.2.1.73.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicyFsm:rn managed object property

cfprApStatsCollectionPolicyFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.73.2.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower stats:CollectionPolicyFsm:completionTime managed object property

cfprApStatsCollectionPolicyFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.73.2.1.5

CfprApStatsCollectionPolicyFsmCurrentFsm0 = nop407 = updateEp · Integer32

Cisco Firepower stats:CollectionPolicyFsm:currentFsm managed object property

cfprApStatsCollectionPolicyFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.73.2.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicyFsm:descr managed object property

cfprApStatsCollectionPolicyFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.73.2.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower stats:CollectionPolicyFsm:fsmStatus managed object property

cfprApStatsCollectionPolicyFsmProgress

1.3.6.1.4.1.9.9.826.2.1.73.2.1.8

Gauge32

Cisco Firepower stats:CollectionPolicyFsm:progress managed object property

cfprApStatsCollectionPolicyFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.73.2.1.9

Gauge32

Cisco Firepower stats:CollectionPolicyFsm:rmtErrCode managed object property

cfprApStatsCollectionPolicyFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.73.2.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicyFsm:rmtErrDescr managed object property

cfprApStatsCollectionPolicyFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.73.2.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower stats:CollectionPolicyFsm:rmtRslt managed object property

cfprApStatsCollectionPolicyFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.73.3

Index: cfprApStatsCollectionPolicyFsmStageInstanceId

Cisco Firepower stats:CollectionPolicyFsmStage managed object table

cfprApStatsCollectionPolicyFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.3.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsCollectionPolicyFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.73.3.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:CollectionPolicyFsmStage:dn managed object property

cfprApStatsCollectionPolicyFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.73.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicyFsmStage:rn managed object property

cfprApStatsCollectionPolicyFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.73.3.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicyFsmStage:descr managed object property

cfprApStatsCollectionPolicyFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.73.3.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower stats:CollectionPolicyFsmStage:lastUpdateTime managed object property

cfprApStatsCollectionPolicyFsmStageName

1.3.6.1.4.1.9.9.826.2.1.73.3.1.6

CfprApStatsCollectionPolicyFsmStageName0 = nop407 = updateEpBegin408 = updateEpSetEpA409 = updateEpSetEpB782 = updateEpFail783 = updateEpSuccess · Integer32

Cisco Firepower stats:CollectionPolicyFsmStage:name managed object property

cfprApStatsCollectionPolicyFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.73.3.1.7

Gauge32

Cisco Firepower stats:CollectionPolicyFsmStage:order managed object property

cfprApStatsCollectionPolicyFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.73.3.1.8

Gauge32

Cisco Firepower stats:CollectionPolicyFsmStage:retry managed object property

cfprApStatsCollectionPolicyFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.73.3.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower stats:CollectionPolicyFsmStage:stageStatus managed object property

cfprApStatsCollectionPolicyFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.73.4

Index: cfprApStatsCollectionPolicyFsmTaskInstanceId

Cisco Firepower stats:CollectionPolicyFsmTask managed object table

cfprApStatsCollectionPolicyFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.4.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsCollectionPolicyFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.73.4.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:CollectionPolicyFsmTask:dn managed object property

cfprApStatsCollectionPolicyFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.73.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:CollectionPolicyFsmTask:rn managed object property

cfprApStatsCollectionPolicyFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.73.4.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower stats:CollectionPolicyFsmTask:completion managed object property

cfprApStatsCollectionPolicyFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.73.4.1.5

CfprApFsmFlags · BITS

Cisco Firepower stats:CollectionPolicyFsmTask:flags managed object property

cfprApStatsCollectionPolicyFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.73.4.1.6

CfprApStatsCollectionPolicyFsmTaskItem0 = nop407 = updateEp · Integer32

Cisco Firepower stats:CollectionPolicyFsmTask:item managed object property

cfprApStatsCollectionPolicyFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.73.4.1.7

Gauge32

Cisco Firepower stats:CollectionPolicyFsmTask:seqId managed object property

cfprApStatsHolderTable

1.3.6.1.4.1.9.9.826.2.1.73.5

Index: cfprApStatsHolderInstanceId

Cisco Firepower stats:Holder managed object table

cfprApStatsHolderInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.5.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsHolderDn

1.3.6.1.4.1.9.9.826.2.1.73.5.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:Holder:dn managed object property

cfprApStatsHolderRn

1.3.6.1.4.1.9.9.826.2.1.73.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Holder:rn managed object property

cfprApStatsHolderName

1.3.6.1.4.1.9.9.826.2.1.73.5.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Holder:name managed object property

cfprApStatsThr32DefinitionTable

1.3.6.1.4.1.9.9.826.2.1.73.6

Index: cfprApStatsThr32DefinitionInstanceId

Cisco Firepower stats:Thr32Definition managed object table

cfprApStatsThr32DefinitionInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.6.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThr32DefinitionDn

1.3.6.1.4.1.9.9.826.2.1.73.6.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:Thr32Definition:dn managed object property

cfprApStatsThr32DefinitionRn

1.3.6.1.4.1.9.9.826.2.1.73.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Definition:rn managed object property

cfprApStatsThr32DefinitionDescr

1.3.6.1.4.1.9.9.826.2.1.73.6.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Definition:descr managed object property

cfprApStatsThr32DefinitionIntId

1.3.6.1.4.1.9.9.826.2.1.73.6.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Definition:intId managed object property

cfprApStatsThr32DefinitionName

1.3.6.1.4.1.9.9.826.2.1.73.6.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Definition:name managed object property

cfprApStatsThr32DefinitionNormalValue

1.3.6.1.4.1.9.9.826.2.1.73.6.1.7

Gauge32

Cisco Firepower stats:Thr32Definition:normalValue managed object property

cfprApStatsThr32DefinitionPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.6.1.8

Gauge32

Cisco Firepower stats:Thr32Definition:policyLevel managed object property

cfprApStatsThr32DefinitionPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.6.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:Thr32Definition:policyOwner managed object property

cfprApStatsThr32DefinitionPropId

1.3.6.1.4.1.9.9.826.2.1.73.6.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Definition:propId managed object property

cfprApStatsThr32DefinitionPropType

1.3.6.1.4.1.9.9.826.2.1.73.6.1.11

CfprApStatsThr32DefinitionPropType1 = uint322 = uint643 = float · Integer32

Cisco Firepower stats:Thr32Definition:propType managed object property

cfprApStatsThr32ValueTable

1.3.6.1.4.1.9.9.826.2.1.73.7

Index: cfprApStatsThr32ValueInstanceId

Cisco Firepower stats:Thr32Value managed object table

cfprApStatsThr32ValueInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.7.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThr32ValueDn

1.3.6.1.4.1.9.9.826.2.1.73.7.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:Thr32Value:dn managed object property

cfprApStatsThr32ValueRn

1.3.6.1.4.1.9.9.826.2.1.73.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Value:rn managed object property

cfprApStatsThr32ValueDeescalating

1.3.6.1.4.1.9.9.826.2.1.73.7.1.4

Gauge32

Cisco Firepower stats:Thr32Value:deescalating managed object property

cfprApStatsThr32ValueDescr

1.3.6.1.4.1.9.9.826.2.1.73.7.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Value:descr managed object property

cfprApStatsThr32ValueDirection

1.3.6.1.4.1.9.9.826.2.1.73.7.1.6

CfprApStatsThresholdDirection1 = aboveNormal2 = belowNormal · Integer32

Cisco Firepower stats:Thr32Value:direction managed object property

cfprApStatsThr32ValueEscalating

1.3.6.1.4.1.9.9.826.2.1.73.7.1.7

Gauge32

Cisco Firepower stats:Thr32Value:escalating managed object property

cfprApStatsThr32ValueIntId

1.3.6.1.4.1.9.9.826.2.1.73.7.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Value:intId managed object property

cfprApStatsThr32ValueName

1.3.6.1.4.1.9.9.826.2.1.73.7.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr32Value:name managed object property

cfprApStatsThr32ValuePolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.7.1.10

Gauge32

Cisco Firepower stats:Thr32Value:policyLevel managed object property

cfprApStatsThr32ValuePolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.7.1.11

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:Thr32Value:policyOwner managed object property

cfprApStatsThr32ValuePropType

1.3.6.1.4.1.9.9.826.2.1.73.7.1.12

CfprApStatsThr32ValuePropType1 = uint322 = uint643 = float · Integer32

Cisco Firepower stats:Thr32Value:propType managed object property

cfprApStatsThr32ValueSeverity

1.3.6.1.4.1.9.9.826.2.1.73.7.1.13

CfprApConditionSeverity0 = cleared1 = info2 = condition3 = warning4 = minor5 = major6 = critical · Integer32

Cisco Firepower stats:Thr32Value:severity managed object property

cfprApStatsThr64DefinitionTable

1.3.6.1.4.1.9.9.826.2.1.73.8

Index: cfprApStatsThr64DefinitionInstanceId

Cisco Firepower stats:Thr64Definition managed object table

cfprApStatsThr64DefinitionInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.8.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThr64DefinitionDn

1.3.6.1.4.1.9.9.826.2.1.73.8.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:Thr64Definition:dn managed object property

cfprApStatsThr64DefinitionRn

1.3.6.1.4.1.9.9.826.2.1.73.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Definition:rn managed object property

cfprApStatsThr64DefinitionDescr

1.3.6.1.4.1.9.9.826.2.1.73.8.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Definition:descr managed object property

cfprApStatsThr64DefinitionIntId

1.3.6.1.4.1.9.9.826.2.1.73.8.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Definition:intId managed object property

cfprApStatsThr64DefinitionName

1.3.6.1.4.1.9.9.826.2.1.73.8.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Definition:name managed object property

cfprApStatsThr64DefinitionNormalValue

1.3.6.1.4.1.9.9.826.2.1.73.8.1.7

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower stats:Thr64Definition:normalValue managed object property

cfprApStatsThr64DefinitionPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.8.1.8

Gauge32

Cisco Firepower stats:Thr64Definition:policyLevel managed object property

cfprApStatsThr64DefinitionPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.8.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:Thr64Definition:policyOwner managed object property

cfprApStatsThr64DefinitionPropId

1.3.6.1.4.1.9.9.826.2.1.73.8.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Definition:propId managed object property

cfprApStatsThr64DefinitionPropType

1.3.6.1.4.1.9.9.826.2.1.73.8.1.11

CfprApStatsThr64DefinitionPropType1 = uint322 = uint643 = float · Integer32

Cisco Firepower stats:Thr64Definition:propType managed object property

cfprApStatsThr64ValueTable

1.3.6.1.4.1.9.9.826.2.1.73.9

Index: cfprApStatsThr64ValueInstanceId

Cisco Firepower stats:Thr64Value managed object table

cfprApStatsThr64ValueInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.9.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThr64ValueDn

1.3.6.1.4.1.9.9.826.2.1.73.9.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:Thr64Value:dn managed object property

cfprApStatsThr64ValueRn

1.3.6.1.4.1.9.9.826.2.1.73.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Value:rn managed object property

cfprApStatsThr64ValueDeescalating

1.3.6.1.4.1.9.9.826.2.1.73.9.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower stats:Thr64Value:deescalating managed object property

cfprApStatsThr64ValueDescr

1.3.6.1.4.1.9.9.826.2.1.73.9.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Value:descr managed object property

cfprApStatsThr64ValueDirection

1.3.6.1.4.1.9.9.826.2.1.73.9.1.6

CfprApStatsThresholdDirection1 = aboveNormal2 = belowNormal · Integer32

Cisco Firepower stats:Thr64Value:direction managed object property

cfprApStatsThr64ValueEscalating

1.3.6.1.4.1.9.9.826.2.1.73.9.1.7

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower stats:Thr64Value:escalating managed object property

cfprApStatsThr64ValueIntId

1.3.6.1.4.1.9.9.826.2.1.73.9.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Value:intId managed object property

cfprApStatsThr64ValueName

1.3.6.1.4.1.9.9.826.2.1.73.9.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:Thr64Value:name managed object property

cfprApStatsThr64ValuePolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.9.1.10

Gauge32

Cisco Firepower stats:Thr64Value:policyLevel managed object property

cfprApStatsThr64ValuePolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.9.1.11

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:Thr64Value:policyOwner managed object property

cfprApStatsThr64ValuePropType

1.3.6.1.4.1.9.9.826.2.1.73.9.1.12

CfprApStatsThr64ValuePropType1 = uint322 = uint643 = float · Integer32

Cisco Firepower stats:Thr64Value:propType managed object property

cfprApStatsThr64ValueSeverity

1.3.6.1.4.1.9.9.826.2.1.73.9.1.13

CfprApConditionSeverity0 = cleared1 = info2 = condition3 = warning4 = minor5 = major6 = critical · Integer32

Cisco Firepower stats:Thr64Value:severity managed object property

cfprApStatsThrFloatDefinitionTable

1.3.6.1.4.1.9.9.826.2.1.73.10

Index: cfprApStatsThrFloatDefinitionInstanceId

Cisco Firepower stats:ThrFloatDefinition managed object table

cfprApStatsThrFloatDefinitionInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.10.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThrFloatDefinitionDn

1.3.6.1.4.1.9.9.826.2.1.73.10.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:ThrFloatDefinition:dn managed object property

cfprApStatsThrFloatDefinitionRn

1.3.6.1.4.1.9.9.826.2.1.73.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatDefinition:rn managed object property

cfprApStatsThrFloatDefinitionDescr

1.3.6.1.4.1.9.9.826.2.1.73.10.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatDefinition:descr managed object property

cfprApStatsThrFloatDefinitionIntId

1.3.6.1.4.1.9.9.826.2.1.73.10.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatDefinition:intId managed object property

cfprApStatsThrFloatDefinitionName

1.3.6.1.4.1.9.9.826.2.1.73.10.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatDefinition:name managed object property

cfprApStatsThrFloatDefinitionNormalValue

1.3.6.1.4.1.9.9.826.2.1.73.10.1.7

INTEGER · Integer32

Cisco Firepower stats:ThrFloatDefinition:normalValue managed object property

cfprApStatsThrFloatDefinitionPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.10.1.8

Gauge32

Cisco Firepower stats:ThrFloatDefinition:policyLevel managed object property

cfprApStatsThrFloatDefinitionPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.10.1.9

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:ThrFloatDefinition:policyOwner managed object property

cfprApStatsThrFloatDefinitionPropId

1.3.6.1.4.1.9.9.826.2.1.73.10.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatDefinition:propId managed object property

cfprApStatsThrFloatDefinitionPropType

1.3.6.1.4.1.9.9.826.2.1.73.10.1.11

CfprApStatsThrFloatDefinitionPropType1 = uint322 = uint643 = float · Integer32

Cisco Firepower stats:ThrFloatDefinition:propType managed object property

cfprApStatsThrFloatValueTable

1.3.6.1.4.1.9.9.826.2.1.73.11

Index: cfprApStatsThrFloatValueInstanceId

Cisco Firepower stats:ThrFloatValue managed object table

cfprApStatsThrFloatValueInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.11.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThrFloatValueDn

1.3.6.1.4.1.9.9.826.2.1.73.11.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:ThrFloatValue:dn managed object property

cfprApStatsThrFloatValueRn

1.3.6.1.4.1.9.9.826.2.1.73.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatValue:rn managed object property

cfprApStatsThrFloatValueDeescalating

1.3.6.1.4.1.9.9.826.2.1.73.11.1.4

INTEGER · Integer32

Cisco Firepower stats:ThrFloatValue:deescalating managed object property

cfprApStatsThrFloatValueDescr

1.3.6.1.4.1.9.9.826.2.1.73.11.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatValue:descr managed object property

cfprApStatsThrFloatValueDirection

1.3.6.1.4.1.9.9.826.2.1.73.11.1.6

CfprApStatsThresholdDirection1 = aboveNormal2 = belowNormal · Integer32

Cisco Firepower stats:ThrFloatValue:direction managed object property

cfprApStatsThrFloatValueEscalating

1.3.6.1.4.1.9.9.826.2.1.73.11.1.7

INTEGER · Integer32

Cisco Firepower stats:ThrFloatValue:escalating managed object property

cfprApStatsThrFloatValueIntId

1.3.6.1.4.1.9.9.826.2.1.73.11.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatValue:intId managed object property

cfprApStatsThrFloatValueName

1.3.6.1.4.1.9.9.826.2.1.73.11.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThrFloatValue:name managed object property

cfprApStatsThrFloatValuePolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.11.1.10

Gauge32

Cisco Firepower stats:ThrFloatValue:policyLevel managed object property

cfprApStatsThrFloatValuePolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.11.1.11

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:ThrFloatValue:policyOwner managed object property

cfprApStatsThrFloatValuePropType

1.3.6.1.4.1.9.9.826.2.1.73.11.1.12

CfprApStatsThrFloatValuePropType1 = uint322 = uint643 = float · Integer32

Cisco Firepower stats:ThrFloatValue:propType managed object property

cfprApStatsThrFloatValueSeverity

1.3.6.1.4.1.9.9.826.2.1.73.11.1.13

CfprApConditionSeverity0 = cleared1 = info2 = condition3 = warning4 = minor5 = major6 = critical · Integer32

Cisco Firepower stats:ThrFloatValue:severity managed object property

cfprApStatsThresholdClassTable

1.3.6.1.4.1.9.9.826.2.1.73.12

Index: cfprApStatsThresholdClassInstanceId

Cisco Firepower stats:ThresholdClass managed object table

cfprApStatsThresholdClassInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.12.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThresholdClassDn

1.3.6.1.4.1.9.9.826.2.1.73.12.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:ThresholdClass:dn managed object property

cfprApStatsThresholdClassRn

1.3.6.1.4.1.9.9.826.2.1.73.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdClass:rn managed object property

cfprApStatsThresholdClassDescr

1.3.6.1.4.1.9.9.826.2.1.73.12.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdClass:descr managed object property

cfprApStatsThresholdClassIntId

1.3.6.1.4.1.9.9.826.2.1.73.12.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdClass:intId managed object property

cfprApStatsThresholdClassName

1.3.6.1.4.1.9.9.826.2.1.73.12.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdClass:name managed object property

cfprApStatsThresholdClassPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.12.1.7

Gauge32

Cisco Firepower stats:ThresholdClass:policyLevel managed object property

cfprApStatsThresholdClassPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.12.1.8

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:ThresholdClass:policyOwner managed object property

cfprApStatsThresholdClassStatsClassId

1.3.6.1.4.1.9.9.826.2.1.73.12.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdClass:statsClassId managed object property

cfprApStatsThresholdPolicyTable

1.3.6.1.4.1.9.9.826.2.1.73.13

Index: cfprApStatsThresholdPolicyInstanceId

Cisco Firepower stats:ThresholdPolicy managed object table

cfprApStatsThresholdPolicyInstanceId

1.3.6.1.4.1.9.9.826.2.1.73.13.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApStatsThresholdPolicyDn

1.3.6.1.4.1.9.9.826.2.1.73.13.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower stats:ThresholdPolicy:dn managed object property

cfprApStatsThresholdPolicyRn

1.3.6.1.4.1.9.9.826.2.1.73.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdPolicy:rn managed object property

cfprApStatsThresholdPolicyDescr

1.3.6.1.4.1.9.9.826.2.1.73.13.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdPolicy:descr managed object property

cfprApStatsThresholdPolicyIntId

1.3.6.1.4.1.9.9.826.2.1.73.13.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdPolicy:intId managed object property

cfprApStatsThresholdPolicyName

1.3.6.1.4.1.9.9.826.2.1.73.13.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower stats:ThresholdPolicy:name managed object property

cfprApStatsThresholdPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.2.1.73.13.1.7

Gauge32

Cisco Firepower stats:ThresholdPolicy:policyLevel managed object property

cfprApStatsThresholdPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.73.13.1.8

CfprApPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower stats:ThresholdPolicy:policyOwner managed object property

↑ To TOC