EZ5 MIB Catalog

CISCO-FIREPOWER-AP-SW-MIB

2023-01-25

MIB representation of the Cisco Firepower SW management information model package

Download CISCO-FIREPOWER-AP-SW-MIB.txt Open CISCO-FIREPOWER-AP-SW-MIB.txt in a new tab

TABLES (78)

Tables (78)

NameOID
cfprApSwAccessDomainTable1.3.6.1.4.1.9.9.826.2.1.75.1
cfprApSwAccessDomainFsmTable1.3.6.1.4.1.9.9.826.2.1.75.2
cfprApSwAccessDomainFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.3
cfprApSwAccessDomainFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.4
cfprApSwAccessEpTable1.3.6.1.4.1.9.9.826.2.1.75.5
cfprApSwCardEnvStatsTable1.3.6.1.4.1.9.9.826.2.1.75.6
cfprApSwCardEnvStatsHistTable1.3.6.1.4.1.9.9.826.2.1.75.7
cfprApSwCmclanTable1.3.6.1.4.1.9.9.826.2.1.75.8
cfprApSwEnvStatsTable1.3.6.1.4.1.9.9.826.2.1.75.9
cfprApSwEnvStatsHistTable1.3.6.1.4.1.9.9.826.2.1.75.10
cfprApSwEthEstcEpTable1.3.6.1.4.1.9.9.826.2.1.75.11
cfprApSwEthEstcPcTable1.3.6.1.4.1.9.9.826.2.1.75.12
cfprApSwEthLanBorderTable1.3.6.1.4.1.9.9.826.2.1.75.13
cfprApSwEthLanBorderFsmTable1.3.6.1.4.1.9.9.826.2.1.75.14
cfprApSwEthLanBorderFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.15
cfprApSwEthLanBorderFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.16
cfprApSwEthLanEpTable1.3.6.1.4.1.9.9.826.2.1.75.17
cfprApSwEthLanMonTable1.3.6.1.4.1.9.9.826.2.1.75.22
cfprApSwEthLanPcTable1.3.6.1.4.1.9.9.826.2.1.75.23
cfprApSwEthMonTable1.3.6.1.4.1.9.9.826.2.1.75.24
cfprApSwEthMonDestEpTable1.3.6.1.4.1.9.9.826.2.1.75.25
cfprApSwEthMonFsmTable1.3.6.1.4.1.9.9.826.2.1.75.26
cfprApSwEthMonFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.27
cfprApSwEthMonFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.28
cfprApSwEthMonSrcEpTable1.3.6.1.4.1.9.9.826.2.1.75.29
cfprApSwEthTargetEpTable1.3.6.1.4.1.9.9.826.2.1.75.30
cfprApSwExtUtilityTable1.3.6.1.4.1.9.9.826.2.1.75.31
cfprApSwExtUtilityFsmTable1.3.6.1.4.1.9.9.826.2.1.75.32
cfprApSwExtUtilityFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.33
cfprApSwExtUtilityFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.34
cfprApSwFabricZoneNsTable1.3.6.1.4.1.9.9.826.2.1.75.35
cfprApSwFabricZoneNsOverrideTable1.3.6.1.4.1.9.9.826.2.1.75.36
cfprApSwFcSanBorderTable1.3.6.1.4.1.9.9.826.2.1.75.44
cfprApSwFcSanBorderFsmTable1.3.6.1.4.1.9.9.826.2.1.75.45
cfprApSwFcSanBorderFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.46
cfprApSwFcSanBorderFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.47
cfprApSwFcSanEpTable1.3.6.1.4.1.9.9.826.2.1.75.48
cfprApSwFcSanPcTable1.3.6.1.4.1.9.9.826.2.1.75.50
cfprApSwFcServerZoneGroupTable1.3.6.1.4.1.9.9.826.2.1.75.51
cfprApSwFcZoneTable1.3.6.1.4.1.9.9.826.2.1.75.52
cfprApSwFcZoneSetTable1.3.6.1.4.1.9.9.826.2.1.75.53
cfprApSwFcoeSanEpTable1.3.6.1.4.1.9.9.826.2.1.75.55
cfprApSwFcoeSanPcTable1.3.6.1.4.1.9.9.826.2.1.75.56
cfprApSwPhysTable1.3.6.1.4.1.9.9.826.2.1.75.64
cfprApSwPhysEtherEpTable1.3.6.1.4.1.9.9.826.2.1.75.65
cfprApSwPhysFcEpTable1.3.6.1.4.1.9.9.826.2.1.75.66
cfprApSwPhysFsmTable1.3.6.1.4.1.9.9.826.2.1.75.67
cfprApSwPhysFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.68
cfprApSwPhysFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.69
cfprApSwPortBreakoutTable1.3.6.1.4.1.9.9.826.2.1.75.70
cfprApSwSspEthLanMonTable1.3.6.1.4.1.9.9.826.2.1.75.71
cfprApSwSspEthMonTable1.3.6.1.4.1.9.9.826.2.1.75.72
cfprApSwSspEthMonFilterEpTable1.3.6.1.4.1.9.9.826.2.1.75.73
cfprApSwSspEthMonFsmTable1.3.6.1.4.1.9.9.826.2.1.75.74
cfprApSwSspEthMonFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.75
cfprApSwSspEthMonFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.76
cfprApSwSspEthMonSrcAppEpTable1.3.6.1.4.1.9.9.826.2.1.75.77
cfprApSwSspEthMonSrcAppLinksEpTable1.3.6.1.4.1.9.9.826.2.1.75.78
cfprApSwSspEthMonSrcPhyEpTable1.3.6.1.4.1.9.9.826.2.1.75.79
cfprApSwSspEthMonSrcPhyEpFsmTable1.3.6.1.4.1.9.9.826.2.1.75.80
cfprApSwSspEthMonSrcPhyEpFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.81
cfprApSwSspEthMonSrcPhyEpFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.82
cfprApSwSubGroupTable1.3.6.1.4.1.9.9.826.2.1.75.83
cfprApSwSystemStatsTable1.3.6.1.4.1.9.9.826.2.1.75.84
cfprApSwSystemStatsHistTable1.3.6.1.4.1.9.9.826.2.1.75.85
cfprApSwUlanTable1.3.6.1.4.1.9.9.826.2.1.75.86
cfprApSwUtilityDomainTable1.3.6.1.4.1.9.9.826.2.1.75.87
cfprApSwUtilityDomainFsmTable1.3.6.1.4.1.9.9.826.2.1.75.88
cfprApSwUtilityDomainFsmStageTable1.3.6.1.4.1.9.9.826.2.1.75.89
cfprApSwUtilityDomainFsmTaskTable1.3.6.1.4.1.9.9.826.2.1.75.90
cfprApSwVlanTable1.3.6.1.4.1.9.9.826.2.1.75.92
cfprApSwVlanGroupTable1.3.6.1.4.1.9.9.826.2.1.75.93
cfprApSwVlanPortNsTable1.3.6.1.4.1.9.9.826.2.1.75.94
cfprApSwVlanPortNsOverrideTable1.3.6.1.4.1.9.9.826.2.1.75.95
cfprApSwVlanRefTable1.3.6.1.4.1.9.9.826.2.1.75.96
cfprApSwVsanTable1.3.6.1.4.1.9.9.826.2.1.75.97
cfprApSwZoneInitiatorMemberTable1.3.6.1.4.1.9.9.826.2.1.75.98
cfprApSwZoneTargetMemberTable1.3.6.1.4.1.9.9.826.2.1.75.99

END OF TOC

Table details

cfprApSwAccessDomainTable

1.3.6.1.4.1.9.9.826.2.1.75.1

Index: cfprApSwAccessDomainInstanceId

Cisco Firepower sw:AccessDomain managed object table

cfprApSwAccessDomainInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.1.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwAccessDomainDn

1.3.6.1.4.1.9.9.826.2.1.75.1.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:AccessDomain:dn managed object property

cfprApSwAccessDomainRn

1.3.6.1.4.1.9.9.826.2.1.75.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:rn managed object property

cfprApSwAccessDomainFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.1.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:fsmDescr managed object property

cfprApSwAccessDomainFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.1.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:fsmPrev managed object property

cfprApSwAccessDomainFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.1.1.6

Gauge32

Cisco Firepower sw:AccessDomain:fsmProgr managed object property

cfprApSwAccessDomainFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.1.1.7

Gauge32

Cisco Firepower sw:AccessDomain:fsmRmtInvErrCode managed object property

cfprApSwAccessDomainFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.1.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:fsmRmtInvErrDescr managed object property

cfprApSwAccessDomainFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.1.1.9

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:AccessDomain:fsmRmtInvRslt managed object property

cfprApSwAccessDomainFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.1.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:fsmStageDescr managed object property

cfprApSwAccessDomainFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.1.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:AccessDomain:fsmStamp managed object property

cfprApSwAccessDomainFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.1.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:fsmStatus managed object property

cfprApSwAccessDomainFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.1.1.13

Gauge32

Cisco Firepower sw:AccessDomain:fsmTry managed object property

cfprApSwAccessDomainLocale

1.3.6.1.4.1.9.9.826.2.1.75.1.1.14

CfprApSwAccessDomainLocale · BITS

Cisco Firepower sw:AccessDomain:locale managed object property

cfprApSwAccessDomainName

1.3.6.1.4.1.9.9.826.2.1.75.1.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomain:name managed object property

cfprApSwAccessDomainSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.1.1.16

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:AccessDomain:switchId managed object property

cfprApSwAccessDomainTransport

1.3.6.1.4.1.9.9.826.2.1.75.1.1.17

CfprApNetworkTransport · BITS

Cisco Firepower sw:AccessDomain:transport managed object property

cfprApSwAccessDomainType

1.3.6.1.4.1.9.9.826.2.1.75.1.1.18

CfprApSwAccessDomainType · BITS

Cisco Firepower sw:AccessDomain:type managed object property

cfprApSwAccessDomainFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.2

Index: cfprApSwAccessDomainFsmInstanceId

Cisco Firepower sw:AccessDomainFsm managed object table

cfprApSwAccessDomainFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.2.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwAccessDomainFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.2.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:AccessDomainFsm:dn managed object property

cfprApSwAccessDomainFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomainFsm:rn managed object property

cfprApSwAccessDomainFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.2.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:AccessDomainFsm:completionTime managed object property

cfprApSwAccessDomainFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.2.1.5

CfprApSwAccessDomainFsmCurrentFsm0 = nop95 = deploy · Integer32

Cisco Firepower sw:AccessDomainFsm:currentFsm managed object property

cfprApSwAccessDomainFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.2.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomainFsm:descr managed object property

cfprApSwAccessDomainFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.2.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:AccessDomainFsm:fsmStatus managed object property

cfprApSwAccessDomainFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.2.1.8

Gauge32

Cisco Firepower sw:AccessDomainFsm:progress managed object property

cfprApSwAccessDomainFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.2.1.9

Gauge32

Cisco Firepower sw:AccessDomainFsm:rmtErrCode managed object property

cfprApSwAccessDomainFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.2.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomainFsm:rmtErrDescr managed object property

cfprApSwAccessDomainFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.2.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:AccessDomainFsm:rmtRslt managed object property

cfprApSwAccessDomainFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.3

Index: cfprApSwAccessDomainFsmStageInstanceId

Cisco Firepower sw:AccessDomainFsmStage managed object table

cfprApSwAccessDomainFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.3.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwAccessDomainFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.3.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:AccessDomainFsmStage:dn managed object property

cfprApSwAccessDomainFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomainFsmStage:rn managed object property

cfprApSwAccessDomainFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.3.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomainFsmStage:descr managed object property

cfprApSwAccessDomainFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.3.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:AccessDomainFsmStage:lastUpdateTime managed object property

cfprApSwAccessDomainFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.3.1.6

CfprApSwAccessDomainFsmStageName0 = nop95 = deployBegin96 = deployUpdateConnectivity786 = deployFail787 = deploySuccess · Integer32

Cisco Firepower sw:AccessDomainFsmStage:name managed object property

cfprApSwAccessDomainFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.3.1.7

Gauge32

Cisco Firepower sw:AccessDomainFsmStage:order managed object property

cfprApSwAccessDomainFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.3.1.8

Gauge32

Cisco Firepower sw:AccessDomainFsmStage:retry managed object property

cfprApSwAccessDomainFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.3.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:AccessDomainFsmStage:stageStatus managed object property

cfprApSwAccessDomainFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.4

Index: cfprApSwAccessDomainFsmTaskInstanceId

Cisco Firepower sw:AccessDomainFsmTask managed object table

cfprApSwAccessDomainFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.4.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwAccessDomainFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.4.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:AccessDomainFsmTask:dn managed object property

cfprApSwAccessDomainFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessDomainFsmTask:rn managed object property

cfprApSwAccessDomainFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.4.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:AccessDomainFsmTask:completion managed object property

cfprApSwAccessDomainFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.4.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:AccessDomainFsmTask:flags managed object property

cfprApSwAccessDomainFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.4.1.6

CfprApSwAccessDomainFsmTaskItem0 = nop95 = deploy · Integer32

Cisco Firepower sw:AccessDomainFsmTask:item managed object property

cfprApSwAccessDomainFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.4.1.7

Gauge32

Cisco Firepower sw:AccessDomainFsmTask:seqId managed object property

cfprApSwAccessEpTable

1.3.6.1.4.1.9.9.826.2.1.75.5

Index: cfprApSwAccessEpInstanceId

Cisco Firepower sw:AccessEp managed object table

cfprApSwAccessEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwAccessEpDn

1.3.6.1.4.1.9.9.826.2.1.75.5.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:AccessEp:dn managed object property

cfprApSwAccessEpRn

1.3.6.1.4.1.9.9.826.2.1.75.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessEp:rn managed object property

cfprApSwAccessEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.5.1.4

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:AccessEp:adminState managed object property

cfprApSwAccessEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.5

Gauge32

Cisco Firepower sw:AccessEp:aggrPortId managed object property

cfprApSwAccessEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.6

Gauge32

Cisco Firepower sw:AccessEp:chassisId managed object property

cfprApSwAccessEpEncap

1.3.6.1.4.1.9.9.826.2.1.75.5.1.7

Gauge32

Cisco Firepower sw:AccessEp:encap managed object property

cfprApSwAccessEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.5.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessEp:epDn managed object property

cfprApSwAccessEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.5.1.9

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:AccessEp:ifRole managed object property

cfprApSwAccessEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.5.1.10

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:AccessEp:ifType managed object property

cfprApSwAccessEpLc

1.3.6.1.4.1.9.9.826.2.1.75.5.1.11

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:AccessEp:lc managed object property

cfprApSwAccessEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.5.1.12

CfprApSwAccessEpLocale · BITS

Cisco Firepower sw:AccessEp:locale managed object property

cfprApSwAccessEpName

1.3.6.1.4.1.9.9.826.2.1.75.5.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessEp:name managed object property

cfprApSwAccessEpNsSize

1.3.6.1.4.1.9.9.826.2.1.75.5.1.14

Gauge32

Cisco Firepower sw:AccessEp:nsSize managed object property

cfprApSwAccessEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.15

Gauge32

Cisco Firepower sw:AccessEp:peerAggrPortId managed object property

cfprApSwAccessEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.16

Gauge32

Cisco Firepower sw:AccessEp:peerChassisId managed object property

cfprApSwAccessEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.5.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:AccessEp:peerDn managed object property

cfprApSwAccessEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.18

Gauge32

Cisco Firepower sw:AccessEp:peerPortId managed object property

cfprApSwAccessEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.19

Gauge32

Cisco Firepower sw:AccessEp:peerSlotId managed object property

cfprApSwAccessEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.20

Gauge32

Cisco Firepower sw:AccessEp:portId managed object property

cfprApSwAccessEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.21

Gauge32

Cisco Firepower sw:AccessEp:slotId managed object property

cfprApSwAccessEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.5.1.22

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:AccessEp:switchId managed object property

cfprApSwAccessEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.5.1.23

CfprApSwAccessEpTransport · BITS

Cisco Firepower sw:AccessEp:transport managed object property

cfprApSwAccessEpType

1.3.6.1.4.1.9.9.826.2.1.75.5.1.24

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:AccessEp:type managed object property

cfprApSwCardEnvStatsTable

1.3.6.1.4.1.9.9.826.2.1.75.6

Index: cfprApSwCardEnvStatsInstanceId

Cisco Firepower sw:CardEnvStats managed object table

cfprApSwCardEnvStatsInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.6.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwCardEnvStatsDn

1.3.6.1.4.1.9.9.826.2.1.75.6.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:CardEnvStats:dn managed object property

cfprApSwCardEnvStatsRn

1.3.6.1.4.1.9.9.826.2.1.75.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:CardEnvStats:rn managed object property

cfprApSwCardEnvStatsSlotOutlet1

1.3.6.1.4.1.9.9.826.2.1.75.6.1.4

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet1 managed object property

cfprApSwCardEnvStatsSlotOutlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.6.1.5

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet1Avg managed object property

cfprApSwCardEnvStatsSlotOutlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.6.1.6

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet1Max managed object property

cfprApSwCardEnvStatsSlotOutlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.6.1.7

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet1Min managed object property

cfprApSwCardEnvStatsSlotOutlet2

1.3.6.1.4.1.9.9.826.2.1.75.6.1.8

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet2 managed object property

cfprApSwCardEnvStatsSlotOutlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.6.1.9

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet2Avg managed object property

cfprApSwCardEnvStatsSlotOutlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.6.1.10

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet2Max managed object property

cfprApSwCardEnvStatsSlotOutlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.6.1.11

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet2Min managed object property

cfprApSwCardEnvStatsSlotOutlet3

1.3.6.1.4.1.9.9.826.2.1.75.6.1.12

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet3 managed object property

cfprApSwCardEnvStatsSlotOutlet3Avg

1.3.6.1.4.1.9.9.826.2.1.75.6.1.13

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet3Avg managed object property

cfprApSwCardEnvStatsSlotOutlet3Max

1.3.6.1.4.1.9.9.826.2.1.75.6.1.14

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet3Max managed object property

cfprApSwCardEnvStatsSlotOutlet3Min

1.3.6.1.4.1.9.9.826.2.1.75.6.1.15

INTEGER · Integer32

Cisco Firepower sw:CardEnvStats:SlotOutlet3Min managed object property

cfprApSwCardEnvStatsIntervals

1.3.6.1.4.1.9.9.826.2.1.75.6.1.16

Gauge32

Cisco Firepower sw:CardEnvStats:intervals managed object property

cfprApSwCardEnvStatsSuspect

1.3.6.1.4.1.9.9.826.2.1.75.6.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:CardEnvStats:suspect managed object property

cfprApSwCardEnvStatsThresholded

1.3.6.1.4.1.9.9.826.2.1.75.6.1.18

CfprApSwCardEnvStatsThresholded · BITS

Cisco Firepower sw:CardEnvStats:thresholded managed object property

cfprApSwCardEnvStatsTimeCollected

1.3.6.1.4.1.9.9.826.2.1.75.6.1.19

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:CardEnvStats:timeCollected managed object property

cfprApSwCardEnvStatsUpdate

1.3.6.1.4.1.9.9.826.2.1.75.6.1.20

Gauge32

Cisco Firepower sw:CardEnvStats:update managed object property

cfprApSwCardEnvStatsHistTable

1.3.6.1.4.1.9.9.826.2.1.75.7

Index: cfprApSwCardEnvStatsHistInstanceId

Cisco Firepower sw:CardEnvStatsHist managed object table

cfprApSwCardEnvStatsHistInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.7.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwCardEnvStatsHistDn

1.3.6.1.4.1.9.9.826.2.1.75.7.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:CardEnvStatsHist:dn managed object property

cfprApSwCardEnvStatsHistRn

1.3.6.1.4.1.9.9.826.2.1.75.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:CardEnvStatsHist:rn managed object property

cfprApSwCardEnvStatsHistSlotOutlet1

1.3.6.1.4.1.9.9.826.2.1.75.7.1.4

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet1 managed object property

cfprApSwCardEnvStatsHistSlotOutlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.7.1.5

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet1Avg managed object property

cfprApSwCardEnvStatsHistSlotOutlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.7.1.6

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet1Max managed object property

cfprApSwCardEnvStatsHistSlotOutlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.7.1.7

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet1Min managed object property

cfprApSwCardEnvStatsHistSlotOutlet2

1.3.6.1.4.1.9.9.826.2.1.75.7.1.8

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet2 managed object property

cfprApSwCardEnvStatsHistSlotOutlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.7.1.9

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet2Avg managed object property

cfprApSwCardEnvStatsHistSlotOutlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.7.1.10

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet2Max managed object property

cfprApSwCardEnvStatsHistSlotOutlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.7.1.11

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet2Min managed object property

cfprApSwCardEnvStatsHistSlotOutlet3

1.3.6.1.4.1.9.9.826.2.1.75.7.1.12

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet3 managed object property

cfprApSwCardEnvStatsHistSlotOutlet3Avg

1.3.6.1.4.1.9.9.826.2.1.75.7.1.13

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet3Avg managed object property

cfprApSwCardEnvStatsHistSlotOutlet3Max

1.3.6.1.4.1.9.9.826.2.1.75.7.1.14

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet3Max managed object property

cfprApSwCardEnvStatsHistSlotOutlet3Min

1.3.6.1.4.1.9.9.826.2.1.75.7.1.15

INTEGER · Integer32

Cisco Firepower sw:CardEnvStatsHist:SlotOutlet3Min managed object property

cfprApSwCardEnvStatsHistId

1.3.6.1.4.1.9.9.826.2.1.75.7.1.16

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:CardEnvStatsHist:id managed object property

cfprApSwCardEnvStatsHistMostRecent

1.3.6.1.4.1.9.9.826.2.1.75.7.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:CardEnvStatsHist:mostRecent managed object property

cfprApSwCardEnvStatsHistSuspect

1.3.6.1.4.1.9.9.826.2.1.75.7.1.18

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:CardEnvStatsHist:suspect managed object property

cfprApSwCardEnvStatsHistThresholded

1.3.6.1.4.1.9.9.826.2.1.75.7.1.19

CfprApSwCardEnvStatsHistThresholded · BITS

Cisco Firepower sw:CardEnvStatsHist:thresholded managed object property

cfprApSwCardEnvStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.2.1.75.7.1.20

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:CardEnvStatsHist:timeCollected managed object property

cfprApSwCmclanTable

1.3.6.1.4.1.9.9.826.2.1.75.8

Index: cfprApSwCmclanInstanceId

Cisco Firepower sw:Cmclan managed object table

cfprApSwCmclanInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.8.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwCmclanDn

1.3.6.1.4.1.9.9.826.2.1.75.8.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:Cmclan:dn managed object property

cfprApSwCmclanRn

1.3.6.1.4.1.9.9.826.2.1.75.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Cmclan:rn managed object property

cfprApSwCmclanCimcIds

1.3.6.1.4.1.9.9.826.2.1.75.8.1.4

CfprApSwCimcId · BITS

Cisco Firepower sw:Cmclan:cimcIds managed object property

cfprApSwCmclanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.8.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Cmclan:epDn managed object property

cfprApSwCmclanId

1.3.6.1.4.1.9.9.826.2.1.75.8.1.6

Gauge32

Cisco Firepower sw:Cmclan:id managed object property

cfprApSwCmclanIfRole

1.3.6.1.4.1.9.9.826.2.1.75.8.1.7

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:Cmclan:ifRole managed object property

cfprApSwCmclanIfType

1.3.6.1.4.1.9.9.826.2.1.75.8.1.8

CfprApNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:Cmclan:ifType managed object property

cfprApSwCmclanLocale

1.3.6.1.4.1.9.9.826.2.1.75.8.1.9

CfprApNetworkLocale · BITS

Cisco Firepower sw:Cmclan:locale managed object property

cfprApSwCmclanName

1.3.6.1.4.1.9.9.826.2.1.75.8.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Cmclan:name managed object property

cfprApSwCmclanPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.8.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Cmclan:peerDn managed object property

cfprApSwCmclanTransport

1.3.6.1.4.1.9.9.826.2.1.75.8.1.12

CfprApNetworkTransport · BITS

Cisco Firepower sw:Cmclan:transport managed object property

cfprApSwCmclanType

1.3.6.1.4.1.9.9.826.2.1.75.8.1.13

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:Cmclan:type managed object property

cfprApSwEnvStatsTable

1.3.6.1.4.1.9.9.826.2.1.75.9

Index: cfprApSwEnvStatsInstanceId

Cisco Firepower sw:EnvStats managed object table

cfprApSwEnvStatsInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.9.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEnvStatsDn

1.3.6.1.4.1.9.9.826.2.1.75.9.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EnvStats:dn managed object property

cfprApSwEnvStatsRn

1.3.6.1.4.1.9.9.826.2.1.75.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EnvStats:rn managed object property

cfprApSwEnvStatsFanCtrlrInlet1

1.3.6.1.4.1.9.9.826.2.1.75.9.1.4

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet1 managed object property

cfprApSwEnvStatsFanCtrlrInlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.5

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet1Avg managed object property

cfprApSwEnvStatsFanCtrlrInlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.6

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet1Max managed object property

cfprApSwEnvStatsFanCtrlrInlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.7

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet1Min managed object property

cfprApSwEnvStatsFanCtrlrInlet2

1.3.6.1.4.1.9.9.826.2.1.75.9.1.8

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet2 managed object property

cfprApSwEnvStatsFanCtrlrInlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.9

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet2Avg managed object property

cfprApSwEnvStatsFanCtrlrInlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.10

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet2Max managed object property

cfprApSwEnvStatsFanCtrlrInlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.11

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet2Min managed object property

cfprApSwEnvStatsFanCtrlrInlet3

1.3.6.1.4.1.9.9.826.2.1.75.9.1.12

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet3 managed object property

cfprApSwEnvStatsFanCtrlrInlet3Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.13

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet3Avg managed object property

cfprApSwEnvStatsFanCtrlrInlet3Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.14

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet3Max managed object property

cfprApSwEnvStatsFanCtrlrInlet3Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.15

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet3Min managed object property

cfprApSwEnvStatsFanCtrlrInlet4

1.3.6.1.4.1.9.9.826.2.1.75.9.1.16

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet4 managed object property

cfprApSwEnvStatsFanCtrlrInlet4Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.17

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet4Avg managed object property

cfprApSwEnvStatsFanCtrlrInlet4Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.18

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet4Max managed object property

cfprApSwEnvStatsFanCtrlrInlet4Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.19

INTEGER · Integer32

Cisco Firepower sw:EnvStats:fanCtrlrInlet4Min managed object property

cfprApSwEnvStatsIntervals

1.3.6.1.4.1.9.9.826.2.1.75.9.1.20

Gauge32

Cisco Firepower sw:EnvStats:intervals managed object property

cfprApSwEnvStatsMainBoardOutlet1

1.3.6.1.4.1.9.9.826.2.1.75.9.1.21

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet1 managed object property

cfprApSwEnvStatsMainBoardOutlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.22

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet1Avg managed object property

cfprApSwEnvStatsMainBoardOutlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.23

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet1Max managed object property

cfprApSwEnvStatsMainBoardOutlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.24

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet1Min managed object property

cfprApSwEnvStatsMainBoardOutlet2

1.3.6.1.4.1.9.9.826.2.1.75.9.1.25

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet2 managed object property

cfprApSwEnvStatsMainBoardOutlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.26

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet2Avg managed object property

cfprApSwEnvStatsMainBoardOutlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.27

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet2Max managed object property

cfprApSwEnvStatsMainBoardOutlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.28

INTEGER · Integer32

Cisco Firepower sw:EnvStats:mainBoardOutlet2Min managed object property

cfprApSwEnvStatsPsuCtrlrInlet1

1.3.6.1.4.1.9.9.826.2.1.75.9.1.29

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet1 managed object property

cfprApSwEnvStatsPsuCtrlrInlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.30

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet1Avg managed object property

cfprApSwEnvStatsPsuCtrlrInlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.31

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet1Max managed object property

cfprApSwEnvStatsPsuCtrlrInlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.32

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet1Min managed object property

cfprApSwEnvStatsPsuCtrlrInlet2

1.3.6.1.4.1.9.9.826.2.1.75.9.1.33

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet2 managed object property

cfprApSwEnvStatsPsuCtrlrInlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.9.1.34

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet2Avg managed object property

cfprApSwEnvStatsPsuCtrlrInlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.9.1.35

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet2Max managed object property

cfprApSwEnvStatsPsuCtrlrInlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.9.1.36

INTEGER · Integer32

Cisco Firepower sw:EnvStats:psuCtrlrInlet2Min managed object property

cfprApSwEnvStatsSuspect

1.3.6.1.4.1.9.9.826.2.1.75.9.1.37

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EnvStats:suspect managed object property

cfprApSwEnvStatsThresholded

1.3.6.1.4.1.9.9.826.2.1.75.9.1.38

CfprApSwEnvStatsThresholded · BITS

Cisco Firepower sw:EnvStats:thresholded managed object property

cfprApSwEnvStatsTimeCollected

1.3.6.1.4.1.9.9.826.2.1.75.9.1.39

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EnvStats:timeCollected managed object property

cfprApSwEnvStatsUpdate

1.3.6.1.4.1.9.9.826.2.1.75.9.1.40

Gauge32

Cisco Firepower sw:EnvStats:update managed object property

cfprApSwEnvStatsHistTable

1.3.6.1.4.1.9.9.826.2.1.75.10

Index: cfprApSwEnvStatsHistInstanceId

Cisco Firepower sw:EnvStatsHist managed object table

cfprApSwEnvStatsHistInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.10.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEnvStatsHistDn

1.3.6.1.4.1.9.9.826.2.1.75.10.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EnvStatsHist:dn managed object property

cfprApSwEnvStatsHistRn

1.3.6.1.4.1.9.9.826.2.1.75.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EnvStatsHist:rn managed object property

cfprApSwEnvStatsHistFanCtrlrInlet1

1.3.6.1.4.1.9.9.826.2.1.75.10.1.4

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet1 managed object property

cfprApSwEnvStatsHistFanCtrlrInlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.5

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet1Avg managed object property

cfprApSwEnvStatsHistFanCtrlrInlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.6

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet1Max managed object property

cfprApSwEnvStatsHistFanCtrlrInlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.7

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet1Min managed object property

cfprApSwEnvStatsHistFanCtrlrInlet2

1.3.6.1.4.1.9.9.826.2.1.75.10.1.8

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet2 managed object property

cfprApSwEnvStatsHistFanCtrlrInlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.9

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet2Avg managed object property

cfprApSwEnvStatsHistFanCtrlrInlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.10

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet2Max managed object property

cfprApSwEnvStatsHistFanCtrlrInlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.11

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet2Min managed object property

cfprApSwEnvStatsHistFanCtrlrInlet3

1.3.6.1.4.1.9.9.826.2.1.75.10.1.12

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet3 managed object property

cfprApSwEnvStatsHistFanCtrlrInlet3Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.13

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet3Avg managed object property

cfprApSwEnvStatsHistFanCtrlrInlet3Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.14

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet3Max managed object property

cfprApSwEnvStatsHistFanCtrlrInlet3Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.15

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet3Min managed object property

cfprApSwEnvStatsHistFanCtrlrInlet4

1.3.6.1.4.1.9.9.826.2.1.75.10.1.16

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet4 managed object property

cfprApSwEnvStatsHistFanCtrlrInlet4Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.17

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet4Avg managed object property

cfprApSwEnvStatsHistFanCtrlrInlet4Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.18

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet4Max managed object property

cfprApSwEnvStatsHistFanCtrlrInlet4Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.19

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:fanCtrlrInlet4Min managed object property

cfprApSwEnvStatsHistId

1.3.6.1.4.1.9.9.826.2.1.75.10.1.20

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:EnvStatsHist:id managed object property

cfprApSwEnvStatsHistMainBoardOutlet1

1.3.6.1.4.1.9.9.826.2.1.75.10.1.21

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet1 managed object property

cfprApSwEnvStatsHistMainBoardOutlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.22

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet1Avg managed object property

cfprApSwEnvStatsHistMainBoardOutlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.23

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet1Max managed object property

cfprApSwEnvStatsHistMainBoardOutlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.24

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet1Min managed object property

cfprApSwEnvStatsHistMainBoardOutlet2

1.3.6.1.4.1.9.9.826.2.1.75.10.1.25

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet2 managed object property

cfprApSwEnvStatsHistMainBoardOutlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.26

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet2Avg managed object property

cfprApSwEnvStatsHistMainBoardOutlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.27

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet2Max managed object property

cfprApSwEnvStatsHistMainBoardOutlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.28

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:mainBoardOutlet2Min managed object property

cfprApSwEnvStatsHistMostRecent

1.3.6.1.4.1.9.9.826.2.1.75.10.1.29

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EnvStatsHist:mostRecent managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet1

1.3.6.1.4.1.9.9.826.2.1.75.10.1.30

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet1 managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet1Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.31

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet1Avg managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet1Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.32

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet1Max managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet1Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.33

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet1Min managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet2

1.3.6.1.4.1.9.9.826.2.1.75.10.1.34

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet2 managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet2Avg

1.3.6.1.4.1.9.9.826.2.1.75.10.1.35

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet2Avg managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet2Max

1.3.6.1.4.1.9.9.826.2.1.75.10.1.36

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet2Max managed object property

cfprApSwEnvStatsHistPsuCtrlrInlet2Min

1.3.6.1.4.1.9.9.826.2.1.75.10.1.37

INTEGER · Integer32

Cisco Firepower sw:EnvStatsHist:psuCtrlrInlet2Min managed object property

cfprApSwEnvStatsHistSuspect

1.3.6.1.4.1.9.9.826.2.1.75.10.1.38

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EnvStatsHist:suspect managed object property

cfprApSwEnvStatsHistThresholded

1.3.6.1.4.1.9.9.826.2.1.75.10.1.39

CfprApSwEnvStatsHistThresholded · BITS

Cisco Firepower sw:EnvStatsHist:thresholded managed object property

cfprApSwEnvStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.2.1.75.10.1.40

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EnvStatsHist:timeCollected managed object property

cfprApSwEthEstcEpTable

1.3.6.1.4.1.9.9.826.2.1.75.11

Index: cfprApSwEthEstcEpInstanceId

Cisco Firepower sw:EthEstcEp managed object table

cfprApSwEthEstcEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthEstcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.11.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthEstcEp:dn managed object property

cfprApSwEthEstcEpRn

1.3.6.1.4.1.9.9.826.2.1.75.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcEp:rn managed object property

cfprApSwEthEstcEpAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.11.1.4

CfprApPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps7 = n100mbps · Integer32

Cisco Firepower sw:EthEstcEp:adminSpeed managed object property

cfprApSwEthEstcEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.11.1.5

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthEstcEp:adminState managed object property

cfprApSwEthEstcEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.6

Gauge32

Cisco Firepower sw:EthEstcEp:aggrPortId managed object property

cfprApSwEthEstcEpBorderAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.7

Gauge32

Cisco Firepower sw:EthEstcEp:borderAggrPortId managed object property

cfprApSwEthEstcEpBorderPortId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.8

Gauge32

Cisco Firepower sw:EthEstcEp:borderPortId managed object property

cfprApSwEthEstcEpBorderSlotId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.9

Gauge32

Cisco Firepower sw:EthEstcEp:borderSlotId managed object property

cfprApSwEthEstcEpCdp

1.3.6.1.4.1.9.9.826.2.1.75.11.1.10

CfprApNwctrlAdminState0 = disabled1 = enabled · Integer32

Cisco Firepower sw:EthEstcEp:cdp managed object property

cfprApSwEthEstcEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.11

Gauge32

Cisco Firepower sw:EthEstcEp:chassisId managed object property

cfprApSwEthEstcEpCosValue

1.3.6.1.4.1.9.9.826.2.1.75.11.1.12

Gauge32

Cisco Firepower sw:EthEstcEp:cosValue managed object property

cfprApSwEthEstcEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.11.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcEp:epDn managed object property

cfprApSwEthEstcEpForgeMac

1.3.6.1.4.1.9.9.826.2.1.75.11.1.14

CfprApDpsecForgedTransmit0 = allow1 = deny · Integer32

Cisco Firepower sw:EthEstcEp:forgeMac managed object property

cfprApSwEthEstcEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.11.1.15

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthEstcEp:ifRole managed object property

cfprApSwEthEstcEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.11.1.16

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthEstcEp:ifType managed object property

cfprApSwEthEstcEpLc

1.3.6.1.4.1.9.9.826.2.1.75.11.1.17

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:EthEstcEp:lc managed object property

cfprApSwEthEstcEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.11.1.18

CfprApSwEstcEpLocale · BITS

Cisco Firepower sw:EthEstcEp:locale managed object property

cfprApSwEthEstcEpName

1.3.6.1.4.1.9.9.826.2.1.75.11.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcEp:name managed object property

cfprApSwEthEstcEpPcId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.20

Gauge32

Cisco Firepower sw:EthEstcEp:pcId managed object property

cfprApSwEthEstcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.21

Gauge32

Cisco Firepower sw:EthEstcEp:peerAggrPortId managed object property

cfprApSwEthEstcEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.22

Gauge32

Cisco Firepower sw:EthEstcEp:peerChassisId managed object property

cfprApSwEthEstcEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.11.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcEp:peerDn managed object property

cfprApSwEthEstcEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.24

Gauge32

Cisco Firepower sw:EthEstcEp:peerPortId managed object property

cfprApSwEthEstcEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.25

Gauge32

Cisco Firepower sw:EthEstcEp:peerSlotId managed object property

cfprApSwEthEstcEpPinGroupName

1.3.6.1.4.1.9.9.826.2.1.75.11.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcEp:pinGroupName managed object property

cfprApSwEthEstcEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.27

Gauge32

Cisco Firepower sw:EthEstcEp:portId managed object property

cfprApSwEthEstcEpPortMode

1.3.6.1.4.1.9.9.826.2.1.75.11.1.28

CfprApFabricEthEstcPortMode1 = trunk2 = access · Integer32

Cisco Firepower sw:EthEstcEp:portMode managed object property

cfprApSwEthEstcEpPriorityFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.11.1.29

CfprApFlowctrlPriorityPause0 = auto1 = on · Integer32

Cisco Firepower sw:EthEstcEp:priorityFlowCtrl managed object property

cfprApSwEthEstcEpRecvFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.11.1.30

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthEstcEp:recvFlowCtrl managed object property

cfprApSwEthEstcEpSendFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.11.1.31

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthEstcEp:sendFlowCtrl managed object property

cfprApSwEthEstcEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.32

Gauge32

Cisco Firepower sw:EthEstcEp:slotId managed object property

cfprApSwEthEstcEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.11.1.33

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthEstcEp:switchId managed object property

cfprApSwEthEstcEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.11.1.34

CfprApSwEthEstcEpTransport · BITS

Cisco Firepower sw:EthEstcEp:transport managed object property

cfprApSwEthEstcEpType

1.3.6.1.4.1.9.9.826.2.1.75.11.1.35

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:EthEstcEp:type managed object property

cfprApSwEthEstcEpUplinkFailAction

1.3.6.1.4.1.9.9.826.2.1.75.11.1.36

CfprApNwctrlLinkFailAction0 = linkDown1 = warning · Integer32

Cisco Firepower sw:EthEstcEp:uplinkFailAction managed object property

cfprApSwEthEstcPcTable

1.3.6.1.4.1.9.9.826.2.1.75.12

Index: cfprApSwEthEstcPcInstanceId

Cisco Firepower sw:EthEstcPc managed object table

cfprApSwEthEstcPcInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.12.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthEstcPcDn

1.3.6.1.4.1.9.9.826.2.1.75.12.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthEstcPc:dn managed object property

cfprApSwEthEstcPcRn

1.3.6.1.4.1.9.9.826.2.1.75.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcPc:rn managed object property

cfprApSwEthEstcPcAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.12.1.4

CfprApPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps7 = n100mbps · Integer32

Cisco Firepower sw:EthEstcPc:adminSpeed managed object property

cfprApSwEthEstcPcAdminState

1.3.6.1.4.1.9.9.826.2.1.75.12.1.5

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthEstcPc:adminState managed object property

cfprApSwEthEstcPcBorderAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.12.1.6

Gauge32

Cisco Firepower sw:EthEstcPc:borderAggrPortId managed object property

cfprApSwEthEstcPcBorderPortId

1.3.6.1.4.1.9.9.826.2.1.75.12.1.7

Gauge32

Cisco Firepower sw:EthEstcPc:borderPortId managed object property

cfprApSwEthEstcPcBorderSlotId

1.3.6.1.4.1.9.9.826.2.1.75.12.1.8

Gauge32

Cisco Firepower sw:EthEstcPc:borderSlotId managed object property

cfprApSwEthEstcPcCdp

1.3.6.1.4.1.9.9.826.2.1.75.12.1.9

CfprApNwctrlAdminState0 = disabled1 = enabled · Integer32

Cisco Firepower sw:EthEstcPc:cdp managed object property

cfprApSwEthEstcPcCosValue

1.3.6.1.4.1.9.9.826.2.1.75.12.1.10

Gauge32

Cisco Firepower sw:EthEstcPc:cosValue managed object property

cfprApSwEthEstcPcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.12.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcPc:epDn managed object property

cfprApSwEthEstcPcForgeMac

1.3.6.1.4.1.9.9.826.2.1.75.12.1.12

CfprApDpsecForgedTransmit0 = allow1 = deny · Integer32

Cisco Firepower sw:EthEstcPc:forgeMac managed object property

cfprApSwEthEstcPcIfRole

1.3.6.1.4.1.9.9.826.2.1.75.12.1.13

CfprApSwLanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthEstcPc:ifRole managed object property

cfprApSwEthEstcPcIfType

1.3.6.1.4.1.9.9.826.2.1.75.12.1.14

CfprApSwCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthEstcPc:ifType managed object property

cfprApSwEthEstcPcLacpFastTimer

1.3.6.1.4.1.9.9.826.2.1.75.12.1.15

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthEstcPc:lacpFastTimer managed object property

cfprApSwEthEstcPcLacpSuspendIndividual

1.3.6.1.4.1.9.9.826.2.1.75.12.1.16

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthEstcPc:lacpSuspendIndividual managed object property

cfprApSwEthEstcPcLocale

1.3.6.1.4.1.9.9.826.2.1.75.12.1.17

CfprApSwBorderPcLocale · BITS

Cisco Firepower sw:EthEstcPc:locale managed object property

cfprApSwEthEstcPcMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.12.1.18

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:EthEstcPc:monTrafDir managed object property

cfprApSwEthEstcPcName

1.3.6.1.4.1.9.9.826.2.1.75.12.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcPc:name managed object property

cfprApSwEthEstcPcPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.12.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthEstcPc:peerDn managed object property

cfprApSwEthEstcPcPortId

1.3.6.1.4.1.9.9.826.2.1.75.12.1.21

Gauge32

Cisco Firepower sw:EthEstcPc:portId managed object property

cfprApSwEthEstcPcPortMode

1.3.6.1.4.1.9.9.826.2.1.75.12.1.22

CfprApFabricEthEstcPortMode1 = trunk2 = access · Integer32

Cisco Firepower sw:EthEstcPc:portMode managed object property

cfprApSwEthEstcPcPriorityFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.12.1.23

CfprApFlowctrlPriorityPause0 = auto1 = on · Integer32

Cisco Firepower sw:EthEstcPc:priorityFlowCtrl managed object property

cfprApSwEthEstcPcProtocol

1.3.6.1.4.1.9.9.826.2.1.75.12.1.24

CfprApFabricEthPcProtocol1 = static2 = lacp · Integer32

Cisco Firepower sw:EthEstcPc:protocol managed object property

cfprApSwEthEstcPcRecvFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.12.1.25

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthEstcPc:recvFlowCtrl managed object property

cfprApSwEthEstcPcSendFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.12.1.26

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthEstcPc:sendFlowCtrl managed object property

cfprApSwEthEstcPcSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.12.1.27

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthEstcPc:switchId managed object property

cfprApSwEthEstcPcTransport

1.3.6.1.4.1.9.9.826.2.1.75.12.1.28

CfprApSwEthEstcPcTransport · BITS

Cisco Firepower sw:EthEstcPc:transport managed object property

cfprApSwEthEstcPcType

1.3.6.1.4.1.9.9.826.2.1.75.12.1.29

CfprApSwLanPcType · BITS

Cisco Firepower sw:EthEstcPc:type managed object property

cfprApSwEthEstcPcUplinkFailAction

1.3.6.1.4.1.9.9.826.2.1.75.12.1.30

CfprApNwctrlLinkFailAction0 = linkDown1 = warning · Integer32

Cisco Firepower sw:EthEstcPc:uplinkFailAction managed object property

cfprApSwEthLanBorderTable

1.3.6.1.4.1.9.9.826.2.1.75.13

Index: cfprApSwEthLanBorderInstanceId

Cisco Firepower sw:EthLanBorder managed object table

cfprApSwEthLanBorderInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.13.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanBorderDn

1.3.6.1.4.1.9.9.826.2.1.75.13.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanBorder:dn managed object property

cfprApSwEthLanBorderRn

1.3.6.1.4.1.9.9.826.2.1.75.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:rn managed object property

cfprApSwEthLanBorderDeployFlag

1.3.6.1.4.1.9.9.826.2.1.75.13.1.4

BITS

Cisco Firepower sw:EthLanBorder:deployFlag managed object property

cfprApSwEthLanBorderFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.13.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:fsmDescr managed object property

cfprApSwEthLanBorderFsmFlags

1.3.6.1.4.1.9.9.826.2.1.75.13.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:fsmFlags managed object property

cfprApSwEthLanBorderFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.13.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:fsmPrev managed object property

cfprApSwEthLanBorderFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.13.1.8

Gauge32

Cisco Firepower sw:EthLanBorder:fsmProgr managed object property

cfprApSwEthLanBorderFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.13.1.9

Gauge32

Cisco Firepower sw:EthLanBorder:fsmRmtInvErrCode managed object property

cfprApSwEthLanBorderFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.13.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:fsmRmtInvErrDescr managed object property

cfprApSwEthLanBorderFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.13.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:EthLanBorder:fsmRmtInvRslt managed object property

cfprApSwEthLanBorderFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.13.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:fsmStageDescr managed object property

cfprApSwEthLanBorderFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.13.1.13

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EthLanBorder:fsmStamp managed object property

cfprApSwEthLanBorderFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.13.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:fsmStatus managed object property

cfprApSwEthLanBorderFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.13.1.15

Gauge32

Cisco Firepower sw:EthLanBorder:fsmTry managed object property

cfprApSwEthLanBorderLocale

1.3.6.1.4.1.9.9.826.2.1.75.13.1.16

CfprApSwBorderDomainLocale · BITS

Cisco Firepower sw:EthLanBorder:locale managed object property

cfprApSwEthLanBorderName

1.3.6.1.4.1.9.9.826.2.1.75.13.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorder:name managed object property

cfprApSwEthLanBorderSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.13.1.18

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthLanBorder:switchId managed object property

cfprApSwEthLanBorderTransport

1.3.6.1.4.1.9.9.826.2.1.75.13.1.19

CfprApSwEthLanBorderTransport · BITS

Cisco Firepower sw:EthLanBorder:transport managed object property

cfprApSwEthLanBorderType

1.3.6.1.4.1.9.9.826.2.1.75.13.1.20

CfprApSwLanBorderType · BITS

Cisco Firepower sw:EthLanBorder:type managed object property

cfprApSwEthLanBorderUdldMsgInterval

1.3.6.1.4.1.9.9.826.2.1.75.13.1.21

Gauge32

Cisco Firepower sw:EthLanBorder:udldMsgInterval managed object property

cfprApSwEthLanBorderUdldRecoveryAction

1.3.6.1.4.1.9.9.826.2.1.75.13.1.22

CfprApFabricRecoveryAction0 = none1 = reset · Integer32

Cisco Firepower sw:EthLanBorder:udldRecoveryAction managed object property

cfprApSwEthLanBorderFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.14

Index: cfprApSwEthLanBorderFsmInstanceId

Cisco Firepower sw:EthLanBorderFsm managed object table

cfprApSwEthLanBorderFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.14.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanBorderFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.14.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanBorderFsm:dn managed object property

cfprApSwEthLanBorderFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.14.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorderFsm:rn managed object property

cfprApSwEthLanBorderFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.14.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EthLanBorderFsm:completionTime managed object property

cfprApSwEthLanBorderFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.14.1.5

CfprApSwEthLanBorderFsmCurrentFsm0 = nop97 = deploy · Integer32

Cisco Firepower sw:EthLanBorderFsm:currentFsm managed object property

cfprApSwEthLanBorderFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.14.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorderFsm:descr managed object property

cfprApSwEthLanBorderFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.14.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:EthLanBorderFsm:fsmStatus managed object property

cfprApSwEthLanBorderFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.14.1.8

Gauge32

Cisco Firepower sw:EthLanBorderFsm:progress managed object property

cfprApSwEthLanBorderFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.14.1.9

Gauge32

Cisco Firepower sw:EthLanBorderFsm:rmtErrCode managed object property

cfprApSwEthLanBorderFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.14.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorderFsm:rmtErrDescr managed object property

cfprApSwEthLanBorderFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.14.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:EthLanBorderFsm:rmtRslt managed object property

cfprApSwEthLanBorderFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.15

Index: cfprApSwEthLanBorderFsmStageInstanceId

Cisco Firepower sw:EthLanBorderFsmStage managed object table

cfprApSwEthLanBorderFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.15.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanBorderFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.15.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanBorderFsmStage:dn managed object property

cfprApSwEthLanBorderFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.15.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorderFsmStage:rn managed object property

cfprApSwEthLanBorderFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.15.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorderFsmStage:descr managed object property

cfprApSwEthLanBorderFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.15.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EthLanBorderFsmStage:lastUpdateTime managed object property

cfprApSwEthLanBorderFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.15.1.6

CfprApSwEthLanBorderFsmStageName0 = nop97 = deployBegin98 = deployUpdateVlanGroups99 = deployUpdateConnectivity788 = deployFail789 = deploySuccess · Integer32

Cisco Firepower sw:EthLanBorderFsmStage:name managed object property

cfprApSwEthLanBorderFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.15.1.7

Gauge32

Cisco Firepower sw:EthLanBorderFsmStage:order managed object property

cfprApSwEthLanBorderFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.15.1.8

Gauge32

Cisco Firepower sw:EthLanBorderFsmStage:retry managed object property

cfprApSwEthLanBorderFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.15.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:EthLanBorderFsmStage:stageStatus managed object property

cfprApSwEthLanBorderFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.16

Index: cfprApSwEthLanBorderFsmTaskInstanceId

Cisco Firepower sw:EthLanBorderFsmTask managed object table

cfprApSwEthLanBorderFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.16.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanBorderFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.16.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanBorderFsmTask:dn managed object property

cfprApSwEthLanBorderFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.16.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanBorderFsmTask:rn managed object property

cfprApSwEthLanBorderFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.16.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:EthLanBorderFsmTask:completion managed object property

cfprApSwEthLanBorderFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.16.1.5

CfprApSwEthLanBorderFsmTaskFlags · BITS

Cisco Firepower sw:EthLanBorderFsmTask:flags managed object property

cfprApSwEthLanBorderFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.16.1.6

CfprApSwEthLanBorderFsmTaskItem0 = nop97 = deploy · Integer32

Cisco Firepower sw:EthLanBorderFsmTask:item managed object property

cfprApSwEthLanBorderFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.16.1.7

Gauge32

Cisco Firepower sw:EthLanBorderFsmTask:seqId managed object property

cfprApSwEthLanEpTable

1.3.6.1.4.1.9.9.826.2.1.75.17

Index: cfprApSwEthLanEpInstanceId

Cisco Firepower sw:EthLanEp managed object table

cfprApSwEthLanEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.17.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanEp:dn managed object property

cfprApSwEthLanEpRn

1.3.6.1.4.1.9.9.826.2.1.75.17.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanEp:rn managed object property

cfprApSwEthLanEpAdminDuplex

1.3.6.1.4.1.9.9.826.2.1.75.17.1.4

CfprApPortDuplex1 = halfDuplex2 = fullDuplex4 = auto · Integer32

Cisco Firepower sw:EthLanEp:adminDuplex managed object property

cfprApSwEthLanEpAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.17.1.5

CfprApPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps7 = n100mbps · Integer32

Cisco Firepower sw:EthLanEp:adminSpeed managed object property

cfprApSwEthLanEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.17.1.6

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthLanEp:adminState managed object property

cfprApSwEthLanEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.7

Gauge32

Cisco Firepower sw:EthLanEp:aggrPortId managed object property

cfprApSwEthLanEpAutoNeg

1.3.6.1.4.1.9.9.826.2.1.75.17.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthLanEp:autoNeg managed object property

cfprApSwEthLanEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.9

Gauge32

Cisco Firepower sw:EthLanEp:chassisId managed object property

cfprApSwEthLanEpDtagVlan

1.3.6.1.4.1.9.9.826.2.1.75.17.1.10

Gauge32

Cisco Firepower sw:EthLanEp:dtagVlan managed object property

cfprApSwEthLanEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.17.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanEp:epDn managed object property

cfprApSwEthLanEpFabRole

1.3.6.1.4.1.9.9.826.2.1.75.17.1.12

CfprApSwFabricRole0 = npu1 = cpu · Integer32

Cisco Firepower sw:EthLanEp:fabRole managed object property

cfprApSwEthLanEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.17.1.14

CfprApSwLanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthLanEp:ifRole managed object property

cfprApSwEthLanEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.17.1.15

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthLanEp:ifType managed object property

cfprApSwEthLanEpLc

1.3.6.1.4.1.9.9.826.2.1.75.17.1.16

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:EthLanEp:lc managed object property

cfprApSwEthLanEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.17.1.17

CfprApSwBorderEpLocale · BITS

Cisco Firepower sw:EthLanEp:locale managed object property

cfprApSwEthLanEpMtu

1.3.6.1.4.1.9.9.826.2.1.75.17.1.18

Gauge32

Cisco Firepower sw:EthLanEp:mtu managed object property

cfprApSwEthLanEpName

1.3.6.1.4.1.9.9.826.2.1.75.17.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanEp:name managed object property

cfprApSwEthLanEpPcId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.20

Gauge32

Cisco Firepower sw:EthLanEp:pcId managed object property

cfprApSwEthLanEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.21

Gauge32

Cisco Firepower sw:EthLanEp:peerAggrPortId managed object property

cfprApSwEthLanEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.22

Gauge32

Cisco Firepower sw:EthLanEp:peerChassisId managed object property

cfprApSwEthLanEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.17.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanEp:peerDn managed object property

cfprApSwEthLanEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.24

Gauge32

Cisco Firepower sw:EthLanEp:peerPortId managed object property

cfprApSwEthLanEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.25

Gauge32

Cisco Firepower sw:EthLanEp:peerSlotId managed object property

cfprApSwEthLanEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.26

Gauge32

Cisco Firepower sw:EthLanEp:portId managed object property

cfprApSwEthLanEpPriorityFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.17.1.27

CfprApFlowctrlPriorityPause0 = auto1 = on · Integer32

Cisco Firepower sw:EthLanEp:priorityFlowCtrl managed object property

cfprApSwEthLanEpQosPrio

1.3.6.1.4.1.9.9.826.2.1.75.17.1.28

CfprApFabricQosPrio0 = low1 = high · Integer32

Cisco Firepower sw:EthLanEp:qosPrio managed object property

cfprApSwEthLanEpRecvFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.17.1.29

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthLanEp:recvFlowCtrl managed object property

cfprApSwEthLanEpSendFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.17.1.30

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthLanEp:sendFlowCtrl managed object property

cfprApSwEthLanEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.31

Gauge32

Cisco Firepower sw:EthLanEp:slotId managed object property

cfprApSwEthLanEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.17.1.32

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthLanEp:switchId managed object property

cfprApSwEthLanEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.17.1.33

CfprApSwEthLanEpTransport · BITS

Cisco Firepower sw:EthLanEp:transport managed object property

cfprApSwEthLanEpType

1.3.6.1.4.1.9.9.826.2.1.75.17.1.34

CfprApSwLanEpType · BITS

Cisco Firepower sw:EthLanEp:type managed object property

cfprApSwEthLanEpUdldAdminState

1.3.6.1.4.1.9.9.826.2.1.75.17.1.35

CfprApSwEthLanEpUdldAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthLanEp:udldAdminState managed object property

cfprApSwEthLanEpUdldMode

1.3.6.1.4.1.9.9.826.2.1.75.17.1.36

CfprApSwEthLanEpUdldMode0 = normal1 = aggressive · Integer32

Cisco Firepower sw:EthLanEp:udldMode managed object property

cfprApSwEthLanMonTable

1.3.6.1.4.1.9.9.826.2.1.75.22

Index: cfprApSwEthLanMonInstanceId

Cisco Firepower sw:EthLanMon managed object table

cfprApSwEthLanMonInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.22.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanMonDn

1.3.6.1.4.1.9.9.826.2.1.75.22.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanMon:dn managed object property

cfprApSwEthLanMonRn

1.3.6.1.4.1.9.9.826.2.1.75.22.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanMon:rn managed object property

cfprApSwEthLanMonLocale

1.3.6.1.4.1.9.9.826.2.1.75.22.1.4

CfprApSwMonDomainLocale · BITS

Cisco Firepower sw:EthLanMon:locale managed object property

cfprApSwEthLanMonName

1.3.6.1.4.1.9.9.826.2.1.75.22.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanMon:name managed object property

cfprApSwEthLanMonSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.22.1.6

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthLanMon:switchId managed object property

cfprApSwEthLanMonTransport

1.3.6.1.4.1.9.9.826.2.1.75.22.1.7

CfprApSwEthLanMonTransport · BITS

Cisco Firepower sw:EthLanMon:transport managed object property

cfprApSwEthLanMonType

1.3.6.1.4.1.9.9.826.2.1.75.22.1.8

CfprApSwLanMonType · BITS

Cisco Firepower sw:EthLanMon:type managed object property

cfprApSwEthLanPcTable

1.3.6.1.4.1.9.9.826.2.1.75.23

Index: cfprApSwEthLanPcInstanceId

Cisco Firepower sw:EthLanPc managed object table

cfprApSwEthLanPcInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.23.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthLanPcDn

1.3.6.1.4.1.9.9.826.2.1.75.23.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthLanPc:dn managed object property

cfprApSwEthLanPcRn

1.3.6.1.4.1.9.9.826.2.1.75.23.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanPc:rn managed object property

cfprApSwEthLanPcAdminDuplex

1.3.6.1.4.1.9.9.826.2.1.75.23.1.4

CfprApPortDuplex1 = halfDuplex2 = fullDuplex4 = auto · Integer32

Cisco Firepower sw:EthLanPc:adminDuplex managed object property

cfprApSwEthLanPcAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.23.1.5

CfprApPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps7 = n100mbps · Integer32

Cisco Firepower sw:EthLanPc:adminSpeed managed object property

cfprApSwEthLanPcAdminState

1.3.6.1.4.1.9.9.826.2.1.75.23.1.6

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthLanPc:adminState managed object property

cfprApSwEthLanPcAutoNeg

1.3.6.1.4.1.9.9.826.2.1.75.23.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthLanPc:autoNeg managed object property

cfprApSwEthLanPcCluChassisId

1.3.6.1.4.1.9.9.826.2.1.75.23.1.8

Gauge32

Cisco Firepower sw:EthLanPc:cluChassisId managed object property

cfprApSwEthLanPcClusterName

1.3.6.1.4.1.9.9.826.2.1.75.23.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanPc:clusterName managed object property

cfprApSwEthLanPcDtagVlan

1.3.6.1.4.1.9.9.826.2.1.75.23.1.10

Gauge32

Cisco Firepower sw:EthLanPc:dtagVlan managed object property

cfprApSwEthLanPcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.23.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanPc:epDn managed object property

cfprApSwEthLanPcFabRole

1.3.6.1.4.1.9.9.826.2.1.75.23.1.12

CfprApSwFabricRole0 = npu1 = cpu · Integer32

Cisco Firepower sw:EthLanPc:fabRole managed object property

cfprApSwEthLanPcIfRole

1.3.6.1.4.1.9.9.826.2.1.75.23.1.14

CfprApSwLanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthLanPc:ifRole managed object property

cfprApSwEthLanPcIfType

1.3.6.1.4.1.9.9.826.2.1.75.23.1.15

CfprApSwCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthLanPc:ifType managed object property

cfprApSwEthLanPcLacpDetach

1.3.6.1.4.1.9.9.826.2.1.75.23.1.16

CfprApSwAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthLanPc:lacpDetach managed object property

cfprApSwEthLanPcLacpFastTimer

1.3.6.1.4.1.9.9.826.2.1.75.23.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthLanPc:lacpFastTimer managed object property

cfprApSwEthLanPcLacpMode

1.3.6.1.4.1.9.9.826.2.1.75.23.1.18

CfprApFabricLacpMode0 = none1 = active2 = on3 = passive · Integer32

Cisco Firepower sw:EthLanPc:lacpMode managed object property

cfprApSwEthLanPcLacpSuspendIndividual

1.3.6.1.4.1.9.9.826.2.1.75.23.1.19

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthLanPc:lacpSuspendIndividual managed object property

cfprApSwEthLanPcLocale

1.3.6.1.4.1.9.9.826.2.1.75.23.1.20

CfprApSwBorderPcLocale · BITS

Cisco Firepower sw:EthLanPc:locale managed object property

cfprApSwEthLanPcMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.23.1.21

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:EthLanPc:monTrafDir managed object property

cfprApSwEthLanPcMtu

1.3.6.1.4.1.9.9.826.2.1.75.23.1.22

Gauge32

Cisco Firepower sw:EthLanPc:mtu managed object property

cfprApSwEthLanPcName

1.3.6.1.4.1.9.9.826.2.1.75.23.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanPc:name managed object property

cfprApSwEthLanPcPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.23.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthLanPc:peerDn managed object property

cfprApSwEthLanPcPortId

1.3.6.1.4.1.9.9.826.2.1.75.23.1.25

Gauge32

Cisco Firepower sw:EthLanPc:portId managed object property

cfprApSwEthLanPcPriorityFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.23.1.26

CfprApFlowctrlPriorityPause0 = auto1 = on · Integer32

Cisco Firepower sw:EthLanPc:priorityFlowCtrl managed object property

cfprApSwEthLanPcQosPrio

1.3.6.1.4.1.9.9.826.2.1.75.23.1.27

CfprApFabricQosPrio0 = low1 = high · Integer32

Cisco Firepower sw:EthLanPc:qosPrio managed object property

cfprApSwEthLanPcRecvFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.23.1.28

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthLanPc:recvFlowCtrl managed object property

cfprApSwEthLanPcSendFlowCtrl

1.3.6.1.4.1.9.9.826.2.1.75.23.1.29

CfprApFlowctrlFlowControl0 = off1 = on · Integer32

Cisco Firepower sw:EthLanPc:sendFlowCtrl managed object property

cfprApSwEthLanPcSpannedCluster

1.3.6.1.4.1.9.9.826.2.1.75.23.1.30

CfprApFabricSpannedCluster1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthLanPc:spannedCluster managed object property

cfprApSwEthLanPcSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.23.1.31

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthLanPc:switchId managed object property

cfprApSwEthLanPcTransport

1.3.6.1.4.1.9.9.826.2.1.75.23.1.32

CfprApSwEthLanPcTransport · BITS

Cisco Firepower sw:EthLanPc:transport managed object property

cfprApSwEthLanPcType

1.3.6.1.4.1.9.9.826.2.1.75.23.1.33

CfprApSwLanPcType · BITS

Cisco Firepower sw:EthLanPc:type managed object property

cfprApSwEthMonTable

1.3.6.1.4.1.9.9.826.2.1.75.24

Index: cfprApSwEthMonInstanceId

Cisco Firepower sw:EthMon managed object table

cfprApSwEthMonInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.24.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthMonDn

1.3.6.1.4.1.9.9.826.2.1.75.24.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthMon:dn managed object property

cfprApSwEthMonRn

1.3.6.1.4.1.9.9.826.2.1.75.24.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:rn managed object property

cfprApSwEthMonAdminState

1.3.6.1.4.1.9.9.826.2.1.75.24.1.4

CfprApSwMonAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthMon:adminState managed object property

cfprApSwEthMonFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.24.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:fsmDescr managed object property

cfprApSwEthMonFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.24.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:fsmPrev managed object property

cfprApSwEthMonFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.24.1.7

Gauge32

Cisco Firepower sw:EthMon:fsmProgr managed object property

cfprApSwEthMonFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.24.1.8

Gauge32

Cisco Firepower sw:EthMon:fsmRmtInvErrCode managed object property

cfprApSwEthMonFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.24.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:fsmRmtInvErrDescr managed object property

cfprApSwEthMonFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.24.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:EthMon:fsmRmtInvRslt managed object property

cfprApSwEthMonFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.24.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:fsmStageDescr managed object property

cfprApSwEthMonFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.24.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EthMon:fsmStamp managed object property

cfprApSwEthMonFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.24.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:fsmStatus managed object property

cfprApSwEthMonFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.24.1.14

Gauge32

Cisco Firepower sw:EthMon:fsmTry managed object property

cfprApSwEthMonHasLastDest

1.3.6.1.4.1.9.9.826.2.1.75.24.1.15

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:EthMon:hasLastDest managed object property

cfprApSwEthMonLifeCycle

1.3.6.1.4.1.9.9.826.2.1.75.24.1.16

CfprApSwMonLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower sw:EthMon:lifeCycle managed object property

cfprApSwEthMonName

1.3.6.1.4.1.9.9.826.2.1.75.24.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:name managed object property

cfprApSwEthMonPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.24.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMon:peerDn managed object property

cfprApSwEthMonSession

1.3.6.1.4.1.9.9.826.2.1.75.24.1.19

Gauge32

Cisco Firepower sw:EthMon:session managed object property

cfprApSwEthMonSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.24.1.20

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthMon:switchId managed object property

cfprApSwEthMonTransport

1.3.6.1.4.1.9.9.826.2.1.75.24.1.21

CfprApSwEthMonTransport · BITS

Cisco Firepower sw:EthMon:transport managed object property

cfprApSwEthMonType

1.3.6.1.4.1.9.9.826.2.1.75.24.1.22

CfprApSwEthMonType · BITS

Cisco Firepower sw:EthMon:type managed object property

cfprApSwEthMonDestEpTable

1.3.6.1.4.1.9.9.826.2.1.75.25

Index: cfprApSwEthMonDestEpInstanceId

Cisco Firepower sw:EthMonDestEp managed object table

cfprApSwEthMonDestEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthMonDestEpDn

1.3.6.1.4.1.9.9.826.2.1.75.25.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthMonDestEp:dn managed object property

cfprApSwEthMonDestEpRn

1.3.6.1.4.1.9.9.826.2.1.75.25.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonDestEp:rn managed object property

cfprApSwEthMonDestEpAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.25.1.4

CfprApPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps7 = n100mbps · Integer32

Cisco Firepower sw:EthMonDestEp:adminSpeed managed object property

cfprApSwEthMonDestEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.25.1.5

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthMonDestEp:adminState managed object property

cfprApSwEthMonDestEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.6

Gauge32

Cisco Firepower sw:EthMonDestEp:aggrPortId managed object property

cfprApSwEthMonDestEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.7

Gauge32

Cisco Firepower sw:EthMonDestEp:chassisId managed object property

cfprApSwEthMonDestEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.25.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonDestEp:epDn managed object property

cfprApSwEthMonDestEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.25.1.9

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthMonDestEp:ifRole managed object property

cfprApSwEthMonDestEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.25.1.10

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthMonDestEp:ifType managed object property

cfprApSwEthMonDestEpLc

1.3.6.1.4.1.9.9.826.2.1.75.25.1.11

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:EthMonDestEp:lc managed object property

cfprApSwEthMonDestEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.25.1.12

CfprApNetworkLocale · BITS

Cisco Firepower sw:EthMonDestEp:locale managed object property

cfprApSwEthMonDestEpName

1.3.6.1.4.1.9.9.826.2.1.75.25.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonDestEp:name managed object property

cfprApSwEthMonDestEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.14

Gauge32

Cisco Firepower sw:EthMonDestEp:peerAggrPortId managed object property

cfprApSwEthMonDestEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.15

Gauge32

Cisco Firepower sw:EthMonDestEp:peerChassisId managed object property

cfprApSwEthMonDestEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.25.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonDestEp:peerDn managed object property

cfprApSwEthMonDestEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.17

Gauge32

Cisco Firepower sw:EthMonDestEp:peerPortId managed object property

cfprApSwEthMonDestEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.18

Gauge32

Cisco Firepower sw:EthMonDestEp:peerSlotId managed object property

cfprApSwEthMonDestEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.19

Gauge32

Cisco Firepower sw:EthMonDestEp:portId managed object property

cfprApSwEthMonDestEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.20

Gauge32

Cisco Firepower sw:EthMonDestEp:slotId managed object property

cfprApSwEthMonDestEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.25.1.21

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthMonDestEp:switchId managed object property

cfprApSwEthMonDestEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.25.1.22

CfprApSwEthMonDestEpTransport · BITS

Cisco Firepower sw:EthMonDestEp:transport managed object property

cfprApSwEthMonDestEpType

1.3.6.1.4.1.9.9.826.2.1.75.25.1.23

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:EthMonDestEp:type managed object property

cfprApSwEthMonFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.26

Index: cfprApSwEthMonFsmInstanceId

Cisco Firepower sw:EthMonFsm managed object table

cfprApSwEthMonFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.26.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthMonFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.26.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthMonFsm:dn managed object property

cfprApSwEthMonFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.26.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonFsm:rn managed object property

cfprApSwEthMonFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.26.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EthMonFsm:completionTime managed object property

cfprApSwEthMonFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.26.1.5

CfprApSwEthMonFsmCurrentFsm0 = nop439 = deploy · Integer32

Cisco Firepower sw:EthMonFsm:currentFsm managed object property

cfprApSwEthMonFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.26.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonFsm:descr managed object property

cfprApSwEthMonFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.26.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:EthMonFsm:fsmStatus managed object property

cfprApSwEthMonFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.26.1.8

Gauge32

Cisco Firepower sw:EthMonFsm:progress managed object property

cfprApSwEthMonFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.26.1.9

Gauge32

Cisco Firepower sw:EthMonFsm:rmtErrCode managed object property

cfprApSwEthMonFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.26.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonFsm:rmtErrDescr managed object property

cfprApSwEthMonFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.26.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:EthMonFsm:rmtRslt managed object property

cfprApSwEthMonFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.27

Index: cfprApSwEthMonFsmStageInstanceId

Cisco Firepower sw:EthMonFsmStage managed object table

cfprApSwEthMonFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.27.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthMonFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.27.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthMonFsmStage:dn managed object property

cfprApSwEthMonFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.27.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonFsmStage:rn managed object property

cfprApSwEthMonFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.27.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonFsmStage:descr managed object property

cfprApSwEthMonFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.27.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:EthMonFsmStage:lastUpdateTime managed object property

cfprApSwEthMonFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.27.1.6

CfprApSwEthMonFsmStageName0 = nop439 = deployBegin440 = deployUpdateEthMon792 = deployFail793 = deploySuccess · Integer32

Cisco Firepower sw:EthMonFsmStage:name managed object property

cfprApSwEthMonFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.27.1.7

Gauge32

Cisco Firepower sw:EthMonFsmStage:order managed object property

cfprApSwEthMonFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.27.1.8

Gauge32

Cisco Firepower sw:EthMonFsmStage:retry managed object property

cfprApSwEthMonFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.27.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:EthMonFsmStage:stageStatus managed object property

cfprApSwEthMonFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.28

Index: cfprApSwEthMonFsmTaskInstanceId

Cisco Firepower sw:EthMonFsmTask managed object table

cfprApSwEthMonFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.28.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthMonFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.28.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthMonFsmTask:dn managed object property

cfprApSwEthMonFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.28.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonFsmTask:rn managed object property

cfprApSwEthMonFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.28.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:EthMonFsmTask:completion managed object property

cfprApSwEthMonFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.28.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:EthMonFsmTask:flags managed object property

cfprApSwEthMonFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.28.1.6

CfprApSwEthMonFsmTaskItem0 = nop439 = deploy · Integer32

Cisco Firepower sw:EthMonFsmTask:item managed object property

cfprApSwEthMonFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.28.1.7

Gauge32

Cisco Firepower sw:EthMonFsmTask:seqId managed object property

cfprApSwEthMonSrcEpTable

1.3.6.1.4.1.9.9.826.2.1.75.29

Index: cfprApSwEthMonSrcEpInstanceId

Cisco Firepower sw:EthMonSrcEp managed object table

cfprApSwEthMonSrcEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthMonSrcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.29.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthMonSrcEp:dn managed object property

cfprApSwEthMonSrcEpRn

1.3.6.1.4.1.9.9.826.2.1.75.29.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonSrcEp:rn managed object property

cfprApSwEthMonSrcEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.29.1.4

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthMonSrcEp:adminState managed object property

cfprApSwEthMonSrcEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.5

Gauge32

Cisco Firepower sw:EthMonSrcEp:aggrPortId managed object property

cfprApSwEthMonSrcEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.6

Gauge32

Cisco Firepower sw:EthMonSrcEp:chassisId managed object property

cfprApSwEthMonSrcEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.29.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonSrcEp:epDn managed object property

cfprApSwEthMonSrcEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.29.1.8

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthMonSrcEp:ifRole managed object property

cfprApSwEthMonSrcEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.29.1.9

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthMonSrcEp:ifType managed object property

cfprApSwEthMonSrcEpLc

1.3.6.1.4.1.9.9.826.2.1.75.29.1.10

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:EthMonSrcEp:lc managed object property

cfprApSwEthMonSrcEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.29.1.11

CfprApSwMonSrcEpLocale · BITS

Cisco Firepower sw:EthMonSrcEp:locale managed object property

cfprApSwEthMonSrcEpMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.29.1.12

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:EthMonSrcEp:monTrafDir managed object property

cfprApSwEthMonSrcEpName

1.3.6.1.4.1.9.9.826.2.1.75.29.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonSrcEp:name managed object property

cfprApSwEthMonSrcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.14

Gauge32

Cisco Firepower sw:EthMonSrcEp:peerAggrPortId managed object property

cfprApSwEthMonSrcEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.15

Gauge32

Cisco Firepower sw:EthMonSrcEp:peerChassisId managed object property

cfprApSwEthMonSrcEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.29.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthMonSrcEp:peerDn managed object property

cfprApSwEthMonSrcEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.17

Gauge32

Cisco Firepower sw:EthMonSrcEp:peerPortId managed object property

cfprApSwEthMonSrcEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.18

Gauge32

Cisco Firepower sw:EthMonSrcEp:peerSlotId managed object property

cfprApSwEthMonSrcEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.19

Gauge32

Cisco Firepower sw:EthMonSrcEp:portId managed object property

cfprApSwEthMonSrcEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.20

Gauge32

Cisco Firepower sw:EthMonSrcEp:slotId managed object property

cfprApSwEthMonSrcEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.29.1.21

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthMonSrcEp:switchId managed object property

cfprApSwEthMonSrcEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.29.1.22

CfprApSwEthMonSrcEpTransport · BITS

Cisco Firepower sw:EthMonSrcEp:transport managed object property

cfprApSwEthMonSrcEpType

1.3.6.1.4.1.9.9.826.2.1.75.29.1.23

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:EthMonSrcEp:type managed object property

cfprApSwEthTargetEpTable

1.3.6.1.4.1.9.9.826.2.1.75.30

Index: cfprApSwEthTargetEpInstanceId

Cisco Firepower sw:EthTargetEp managed object table

cfprApSwEthTargetEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwEthTargetEpDn

1.3.6.1.4.1.9.9.826.2.1.75.30.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:EthTargetEp:dn managed object property

cfprApSwEthTargetEpRn

1.3.6.1.4.1.9.9.826.2.1.75.30.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthTargetEp:rn managed object property

cfprApSwEthTargetEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.30.1.4

CfprApSwEthTargetEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:EthTargetEp:adminState managed object property

cfprApSwEthTargetEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.5

Gauge32

Cisco Firepower sw:EthTargetEp:aggrPortId managed object property

cfprApSwEthTargetEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.6

Gauge32

Cisco Firepower sw:EthTargetEp:chassisId managed object property

cfprApSwEthTargetEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.30.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthTargetEp:epDn managed object property

cfprApSwEthTargetEpFltAggr

1.3.6.1.4.1.9.9.826.2.1.75.30.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:EthTargetEp:fltAggr managed object property

cfprApSwEthTargetEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.30.1.9

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:EthTargetEp:ifRole managed object property

cfprApSwEthTargetEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.30.1.10

CfprApFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:EthTargetEp:ifType managed object property

cfprApSwEthTargetEpLicGP

1.3.6.1.4.1.9.9.826.2.1.75.30.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:EthTargetEp:licGP managed object property

cfprApSwEthTargetEpLicState

1.3.6.1.4.1.9.9.826.2.1.75.30.1.12

CfprApLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower sw:EthTargetEp:licState managed object property

cfprApSwEthTargetEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.30.1.13

CfprApFabricExternalEpLocale · BITS

Cisco Firepower sw:EthTargetEp:locale managed object property

cfprApSwEthTargetEpMacAddress

1.3.6.1.4.1.9.9.826.2.1.75.30.1.14

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower sw:EthTargetEp:macAddress managed object property

cfprApSwEthTargetEpName

1.3.6.1.4.1.9.9.826.2.1.75.30.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthTargetEp:name managed object property

cfprApSwEthTargetEpOperState

1.3.6.1.4.1.9.9.826.2.1.75.30.1.16

CfprApFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower sw:EthTargetEp:operState managed object property

cfprApSwEthTargetEpOperStateReason

1.3.6.1.4.1.9.9.826.2.1.75.30.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthTargetEp:operStateReason managed object property

cfprApSwEthTargetEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.18

Gauge32

Cisco Firepower sw:EthTargetEp:peerAggrPortId managed object property

cfprApSwEthTargetEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.19

Gauge32

Cisco Firepower sw:EthTargetEp:peerChassisId managed object property

cfprApSwEthTargetEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.30.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:EthTargetEp:peerDn managed object property

cfprApSwEthTargetEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.21

Gauge32

Cisco Firepower sw:EthTargetEp:peerPortId managed object property

cfprApSwEthTargetEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.22

Gauge32

Cisco Firepower sw:EthTargetEp:peerSlotId managed object property

cfprApSwEthTargetEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.23

CfprApFabricPIoEpPortId (1..48) · Gauge32

Cisco Firepower sw:EthTargetEp:portId managed object property

cfprApSwEthTargetEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.24

CfprApFabricPIoEpSlotId (1..4) · Gauge32

Cisco Firepower sw:EthTargetEp:slotId managed object property

cfprApSwEthTargetEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.30.1.25

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:EthTargetEp:switchId managed object property

cfprApSwEthTargetEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.30.1.26

CfprApSwEthTargetEpTransport · BITS

Cisco Firepower sw:EthTargetEp:transport managed object property

cfprApSwEthTargetEpType

1.3.6.1.4.1.9.9.826.2.1.75.30.1.27

CfprApSwTargetEpType · BITS

Cisco Firepower sw:EthTargetEp:type managed object property

cfprApSwEthTargetEpWarnings

1.3.6.1.4.1.9.9.826.2.1.75.30.1.28

CfprApFabricWarnings · BITS

Cisco Firepower sw:EthTargetEp:warnings managed object property

cfprApSwExtUtilityTable

1.3.6.1.4.1.9.9.826.2.1.75.31

Index: cfprApSwExtUtilityInstanceId

Cisco Firepower sw:ExtUtility managed object table

cfprApSwExtUtilityInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.31.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwExtUtilityDn

1.3.6.1.4.1.9.9.826.2.1.75.31.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:ExtUtility:dn managed object property

cfprApSwExtUtilityRn

1.3.6.1.4.1.9.9.826.2.1.75.31.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtility:rn managed object property

cfprApSwExtUtilityConfMode

1.3.6.1.4.1.9.9.826.2.1.75.31.1.4

CfprApSwConfMode0 = none1 = inProgress2 = verifying3 = failed · Integer32

Cisco Firepower sw:ExtUtility:confMode managed object property

cfprApSwExtUtilityFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.31.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtility:fsmDescr managed object property

cfprApSwExtUtilityFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.31.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtility:fsmPrev managed object property

cfprApSwExtUtilityFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.31.1.7

Gauge32

Cisco Firepower sw:ExtUtility:fsmProgr managed object property

cfprApSwExtUtilityFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.31.1.8

Gauge32

Cisco Firepower sw:ExtUtility:fsmRmtInvErrCode managed object property

cfprApSwExtUtilityFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.31.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtility:fsmRmtInvErrDescr managed object property

cfprApSwExtUtilityFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.31.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:ExtUtility:fsmRmtInvRslt managed object property

cfprApSwExtUtilityFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.31.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtility:fsmStageDescr managed object property

cfprApSwExtUtilityFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.31.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:ExtUtility:fsmStamp managed object property

cfprApSwExtUtilityFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.31.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtility:fsmStatus managed object property

cfprApSwExtUtilityFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.31.1.14

Gauge32

Cisco Firepower sw:ExtUtility:fsmTry managed object property

cfprApSwExtUtilitySwitchId

1.3.6.1.4.1.9.9.826.2.1.75.31.1.15

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:ExtUtility:switchId managed object property

cfprApSwExtUtilityFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.32

Index: cfprApSwExtUtilityFsmInstanceId

Cisco Firepower sw:ExtUtilityFsm managed object table

cfprApSwExtUtilityFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.32.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwExtUtilityFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.32.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:ExtUtilityFsm:dn managed object property

cfprApSwExtUtilityFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.32.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtilityFsm:rn managed object property

cfprApSwExtUtilityFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.32.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:ExtUtilityFsm:completionTime managed object property

cfprApSwExtUtilityFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.32.1.5

CfprApSwExtUtilityFsmCurrentFsm0 = nop114 = confPortBreakout · Integer32

Cisco Firepower sw:ExtUtilityFsm:currentFsm managed object property

cfprApSwExtUtilityFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.32.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtilityFsm:descr managed object property

cfprApSwExtUtilityFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.32.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:ExtUtilityFsm:fsmStatus managed object property

cfprApSwExtUtilityFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.32.1.8

Gauge32

Cisco Firepower sw:ExtUtilityFsm:progress managed object property

cfprApSwExtUtilityFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.32.1.9

Gauge32

Cisco Firepower sw:ExtUtilityFsm:rmtErrCode managed object property

cfprApSwExtUtilityFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.32.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtilityFsm:rmtErrDescr managed object property

cfprApSwExtUtilityFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.32.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:ExtUtilityFsm:rmtRslt managed object property

cfprApSwExtUtilityFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.33

Index: cfprApSwExtUtilityFsmStageInstanceId

Cisco Firepower sw:ExtUtilityFsmStage managed object table

cfprApSwExtUtilityFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.33.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwExtUtilityFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.33.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:ExtUtilityFsmStage:dn managed object property

cfprApSwExtUtilityFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.33.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtilityFsmStage:rn managed object property

cfprApSwExtUtilityFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.33.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtilityFsmStage:descr managed object property

cfprApSwExtUtilityFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.33.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:ExtUtilityFsmStage:lastUpdateTime managed object property

cfprApSwExtUtilityFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.33.1.6

CfprApSwExtUtilityFsmStageName0 = nop114 = confPortBreakoutBegin115 = confPortBreakoutPortInventorySwA116 = confPortBreakoutPortInventorySwB117 = confPortBreakoutConfigSwA118 = confPortBreakoutConfigSwB119 = confPortBreakoutVerifyBreakoutConfig120 = confPortBreakoutSuccess121 = confPortBreakoutFail · Integer32

Cisco Firepower sw:ExtUtilityFsmStage:name managed object property

cfprApSwExtUtilityFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.33.1.7

Gauge32

Cisco Firepower sw:ExtUtilityFsmStage:order managed object property

cfprApSwExtUtilityFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.33.1.8

Gauge32

Cisco Firepower sw:ExtUtilityFsmStage:retry managed object property

cfprApSwExtUtilityFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.33.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:ExtUtilityFsmStage:stageStatus managed object property

cfprApSwExtUtilityFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.34

Index: cfprApSwExtUtilityFsmTaskInstanceId

Cisco Firepower sw:ExtUtilityFsmTask managed object table

cfprApSwExtUtilityFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.34.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwExtUtilityFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.34.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:ExtUtilityFsmTask:dn managed object property

cfprApSwExtUtilityFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.34.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ExtUtilityFsmTask:rn managed object property

cfprApSwExtUtilityFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.34.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:ExtUtilityFsmTask:completion managed object property

cfprApSwExtUtilityFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.34.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:ExtUtilityFsmTask:flags managed object property

cfprApSwExtUtilityFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.34.1.6

CfprApSwExtUtilityFsmTaskItem0 = nop114 = confPortBreakout · Integer32

Cisco Firepower sw:ExtUtilityFsmTask:item managed object property

cfprApSwExtUtilityFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.34.1.7

Gauge32

Cisco Firepower sw:ExtUtilityFsmTask:seqId managed object property

cfprApSwFabricZoneNsTable

1.3.6.1.4.1.9.9.826.2.1.75.35

Index: cfprApSwFabricZoneNsInstanceId

Cisco Firepower sw:FabricZoneNs managed object table

cfprApSwFabricZoneNsInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.35.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFabricZoneNsDn

1.3.6.1.4.1.9.9.826.2.1.75.35.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FabricZoneNs:dn managed object property

cfprApSwFabricZoneNsRn

1.3.6.1.4.1.9.9.826.2.1.75.35.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FabricZoneNs:rn managed object property

cfprApSwFabricZoneNsAllocStatus

1.3.6.1.4.1.9.9.826.2.1.75.35.1.4

CfprApSwFabricZoneNsAllocStatus0 = available1 = full · Integer32

Cisco Firepower sw:FabricZoneNs:allocStatus managed object property

cfprApSwFabricZoneNsLimit

1.3.6.1.4.1.9.9.826.2.1.75.35.1.5

Gauge32

Cisco Firepower sw:FabricZoneNs:limit managed object property

cfprApSwFabricZoneNsSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.35.1.6

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:FabricZoneNs:switchId managed object property

cfprApSwFabricZoneNsZoneCount

1.3.6.1.4.1.9.9.826.2.1.75.35.1.7

Gauge32

Cisco Firepower sw:FabricZoneNs:zoneCount managed object property

cfprApSwFabricZoneNsOverrideTable

1.3.6.1.4.1.9.9.826.2.1.75.36

Index: cfprApSwFabricZoneNsOverrideInstanceId

Cisco Firepower sw:FabricZoneNsOverride managed object table

cfprApSwFabricZoneNsOverrideInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.36.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFabricZoneNsOverrideDn

1.3.6.1.4.1.9.9.826.2.1.75.36.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FabricZoneNsOverride:dn managed object property

cfprApSwFabricZoneNsOverrideRn

1.3.6.1.4.1.9.9.826.2.1.75.36.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FabricZoneNsOverride:rn managed object property

cfprApSwFabricZoneNsOverrideLimit

1.3.6.1.4.1.9.9.826.2.1.75.36.1.4

Gauge32

Cisco Firepower sw:FabricZoneNsOverride:limit managed object property

cfprApSwFcSanBorderTable

1.3.6.1.4.1.9.9.826.2.1.75.44

Index: cfprApSwFcSanBorderInstanceId

Cisco Firepower sw:FcSanBorder managed object table

cfprApSwFcSanBorderInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.44.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcSanBorderDn

1.3.6.1.4.1.9.9.826.2.1.75.44.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcSanBorder:dn managed object property

cfprApSwFcSanBorderRn

1.3.6.1.4.1.9.9.826.2.1.75.44.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:rn managed object property

cfprApSwFcSanBorderFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.44.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:fsmDescr managed object property

cfprApSwFcSanBorderFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.44.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:fsmPrev managed object property

cfprApSwFcSanBorderFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.44.1.6

Gauge32

Cisco Firepower sw:FcSanBorder:fsmProgr managed object property

cfprApSwFcSanBorderFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.44.1.7

Gauge32

Cisco Firepower sw:FcSanBorder:fsmRmtInvErrCode managed object property

cfprApSwFcSanBorderFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.44.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:fsmRmtInvErrDescr managed object property

cfprApSwFcSanBorderFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.44.1.9

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:FcSanBorder:fsmRmtInvRslt managed object property

cfprApSwFcSanBorderFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.44.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:fsmStageDescr managed object property

cfprApSwFcSanBorderFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.44.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:FcSanBorder:fsmStamp managed object property

cfprApSwFcSanBorderFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.44.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:fsmStatus managed object property

cfprApSwFcSanBorderFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.44.1.13

Gauge32

Cisco Firepower sw:FcSanBorder:fsmTry managed object property

cfprApSwFcSanBorderLocale

1.3.6.1.4.1.9.9.826.2.1.75.44.1.14

CfprApSwBorderDomainLocale · BITS

Cisco Firepower sw:FcSanBorder:locale managed object property

cfprApSwFcSanBorderName

1.3.6.1.4.1.9.9.826.2.1.75.44.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorder:name managed object property

cfprApSwFcSanBorderSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.44.1.16

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:FcSanBorder:switchId managed object property

cfprApSwFcSanBorderTransport

1.3.6.1.4.1.9.9.826.2.1.75.44.1.17

CfprApSwFcSanBorderTransport · BITS

Cisco Firepower sw:FcSanBorder:transport managed object property

cfprApSwFcSanBorderType

1.3.6.1.4.1.9.9.826.2.1.75.44.1.18

CfprApSwSanBorderType · BITS

Cisco Firepower sw:FcSanBorder:type managed object property

cfprApSwFcSanBorderUplinkTrunking

1.3.6.1.4.1.9.9.826.2.1.75.44.1.19

CfprApSwFcSanBorderUplinkTrunking0 = disabled1 = enabled · Integer32

Cisco Firepower sw:FcSanBorder:uplinkTrunking managed object property

cfprApSwFcSanBorderFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.45

Index: cfprApSwFcSanBorderFsmInstanceId

Cisco Firepower sw:FcSanBorderFsm managed object table

cfprApSwFcSanBorderFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.45.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcSanBorderFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.45.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcSanBorderFsm:dn managed object property

cfprApSwFcSanBorderFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.45.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorderFsm:rn managed object property

cfprApSwFcSanBorderFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.45.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:FcSanBorderFsm:completionTime managed object property

cfprApSwFcSanBorderFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.45.1.5

CfprApSwFcSanBorderFsmCurrentFsm0 = nop100 = deploy122 = activateZoneSet · Integer32

Cisco Firepower sw:FcSanBorderFsm:currentFsm managed object property

cfprApSwFcSanBorderFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.45.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorderFsm:descr managed object property

cfprApSwFcSanBorderFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.45.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:FcSanBorderFsm:fsmStatus managed object property

cfprApSwFcSanBorderFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.45.1.8

Gauge32

Cisco Firepower sw:FcSanBorderFsm:progress managed object property

cfprApSwFcSanBorderFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.45.1.9

Gauge32

Cisco Firepower sw:FcSanBorderFsm:rmtErrCode managed object property

cfprApSwFcSanBorderFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.45.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorderFsm:rmtErrDescr managed object property

cfprApSwFcSanBorderFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.45.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:FcSanBorderFsm:rmtRslt managed object property

cfprApSwFcSanBorderFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.46

Index: cfprApSwFcSanBorderFsmStageInstanceId

Cisco Firepower sw:FcSanBorderFsmStage managed object table

cfprApSwFcSanBorderFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.46.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcSanBorderFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.46.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcSanBorderFsmStage:dn managed object property

cfprApSwFcSanBorderFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.46.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorderFsmStage:rn managed object property

cfprApSwFcSanBorderFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.46.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorderFsmStage:descr managed object property

cfprApSwFcSanBorderFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.46.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:FcSanBorderFsmStage:lastUpdateTime managed object property

cfprApSwFcSanBorderFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.46.1.6

CfprApSwFcSanBorderFsmStageName0 = nop100 = deployBegin101 = deployUpdateConnectivity122 = activateZoneSetBegin123 = activateZoneSetUpdateZones796 = activateZoneSetFail797 = activateZoneSetSuccess798 = deployFail799 = deploySuccess · Integer32

Cisco Firepower sw:FcSanBorderFsmStage:name managed object property

cfprApSwFcSanBorderFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.46.1.7

Gauge32

Cisco Firepower sw:FcSanBorderFsmStage:order managed object property

cfprApSwFcSanBorderFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.46.1.8

Gauge32

Cisco Firepower sw:FcSanBorderFsmStage:retry managed object property

cfprApSwFcSanBorderFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.46.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:FcSanBorderFsmStage:stageStatus managed object property

cfprApSwFcSanBorderFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.47

Index: cfprApSwFcSanBorderFsmTaskInstanceId

Cisco Firepower sw:FcSanBorderFsmTask managed object table

cfprApSwFcSanBorderFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.47.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcSanBorderFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.47.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcSanBorderFsmTask:dn managed object property

cfprApSwFcSanBorderFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.47.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanBorderFsmTask:rn managed object property

cfprApSwFcSanBorderFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.47.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:FcSanBorderFsmTask:completion managed object property

cfprApSwFcSanBorderFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.47.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:FcSanBorderFsmTask:flags managed object property

cfprApSwFcSanBorderFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.47.1.6

CfprApSwFcSanBorderFsmTaskItem0 = nop100 = deploy122 = activateZoneSet · Integer32

Cisco Firepower sw:FcSanBorderFsmTask:item managed object property

cfprApSwFcSanBorderFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.47.1.7

Gauge32

Cisco Firepower sw:FcSanBorderFsmTask:seqId managed object property

cfprApSwFcSanEpTable

1.3.6.1.4.1.9.9.826.2.1.75.48

Index: cfprApSwFcSanEpInstanceId

Cisco Firepower sw:FcSanEp managed object table

cfprApSwFcSanEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcSanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.48.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcSanEp:dn managed object property

cfprApSwFcSanEpRn

1.3.6.1.4.1.9.9.826.2.1.75.48.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanEp:rn managed object property

cfprApSwFcSanEpAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.48.1.4

CfprApPortSpeed0 = indeterminate1 = n1gbps2 = n2gbps3 = n4gbps4 = n8gbps5 = auto · Integer32

Cisco Firepower sw:FcSanEp:adminSpeed managed object property

cfprApSwFcSanEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.48.1.5

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:FcSanEp:adminState managed object property

cfprApSwFcSanEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.6

Gauge32

Cisco Firepower sw:FcSanEp:aggrPortId managed object property

cfprApSwFcSanEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.7

Gauge32

Cisco Firepower sw:FcSanEp:chassisId managed object property

cfprApSwFcSanEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.48.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanEp:epDn managed object property

cfprApSwFcSanEpFillPattern

1.3.6.1.4.1.9.9.826.2.1.75.48.1.9

CfprApFabricFillPattern0 = idle1 = arbff · Integer32

Cisco Firepower sw:FcSanEp:fillPattern managed object property

cfprApSwFcSanEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.48.1.10

CfprApSwSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:FcSanEp:ifRole managed object property

cfprApSwFcSanEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.48.1.11

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:FcSanEp:ifType managed object property

cfprApSwFcSanEpLc

1.3.6.1.4.1.9.9.826.2.1.75.48.1.12

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:FcSanEp:lc managed object property

cfprApSwFcSanEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.48.1.13

CfprApSwBorderEpLocale · BITS

Cisco Firepower sw:FcSanEp:locale managed object property

cfprApSwFcSanEpName

1.3.6.1.4.1.9.9.826.2.1.75.48.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanEp:name managed object property

cfprApSwFcSanEpPcId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.15

Gauge32

Cisco Firepower sw:FcSanEp:pcId managed object property

cfprApSwFcSanEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.16

Gauge32

Cisco Firepower sw:FcSanEp:peerAggrPortId managed object property

cfprApSwFcSanEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.17

Gauge32

Cisco Firepower sw:FcSanEp:peerChassisId managed object property

cfprApSwFcSanEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.48.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanEp:peerDn managed object property

cfprApSwFcSanEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.19

Gauge32

Cisco Firepower sw:FcSanEp:peerPortId managed object property

cfprApSwFcSanEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.20

Gauge32

Cisco Firepower sw:FcSanEp:peerSlotId managed object property

cfprApSwFcSanEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.21

Gauge32

Cisco Firepower sw:FcSanEp:portId managed object property

cfprApSwFcSanEpPortVsanId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.22

Gauge32

Cisco Firepower sw:FcSanEp:portVsanId managed object property

cfprApSwFcSanEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.23

Gauge32

Cisco Firepower sw:FcSanEp:slotId managed object property

cfprApSwFcSanEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.48.1.24

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:FcSanEp:switchId managed object property

cfprApSwFcSanEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.48.1.25

CfprApSwFcSanEpTransport · BITS

Cisco Firepower sw:FcSanEp:transport managed object property

cfprApSwFcSanEpType

1.3.6.1.4.1.9.9.826.2.1.75.48.1.26

CfprApSwSanEpType · BITS

Cisco Firepower sw:FcSanEp:type managed object property

cfprApSwFcSanPcTable

1.3.6.1.4.1.9.9.826.2.1.75.50

Index: cfprApSwFcSanPcInstanceId

Cisco Firepower sw:FcSanPc managed object table

cfprApSwFcSanPcInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.50.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcSanPcDn

1.3.6.1.4.1.9.9.826.2.1.75.50.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcSanPc:dn managed object property

cfprApSwFcSanPcRn

1.3.6.1.4.1.9.9.826.2.1.75.50.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanPc:rn managed object property

cfprApSwFcSanPcAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.50.1.4

CfprApPortSpeed0 = indeterminate1 = n1gbps2 = n2gbps3 = n4gbps4 = n8gbps5 = auto · Integer32

Cisco Firepower sw:FcSanPc:adminSpeed managed object property

cfprApSwFcSanPcAdminState

1.3.6.1.4.1.9.9.826.2.1.75.50.1.5

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:FcSanPc:adminState managed object property

cfprApSwFcSanPcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.50.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanPc:epDn managed object property

cfprApSwFcSanPcIfRole

1.3.6.1.4.1.9.9.826.2.1.75.50.1.7

CfprApSwSanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:FcSanPc:ifRole managed object property

cfprApSwFcSanPcIfType

1.3.6.1.4.1.9.9.826.2.1.75.50.1.8

CfprApSwCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:FcSanPc:ifType managed object property

cfprApSwFcSanPcLocale

1.3.6.1.4.1.9.9.826.2.1.75.50.1.9

CfprApSwBorderPcLocale · BITS

Cisco Firepower sw:FcSanPc:locale managed object property

cfprApSwFcSanPcMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.50.1.10

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:FcSanPc:monTrafDir managed object property

cfprApSwFcSanPcName

1.3.6.1.4.1.9.9.826.2.1.75.50.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanPc:name managed object property

cfprApSwFcSanPcPcId

1.3.6.1.4.1.9.9.826.2.1.75.50.1.12

Gauge32

Cisco Firepower sw:FcSanPc:pcId managed object property

cfprApSwFcSanPcPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.50.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcSanPc:peerDn managed object property

cfprApSwFcSanPcPortId

1.3.6.1.4.1.9.9.826.2.1.75.50.1.14

Gauge32

Cisco Firepower sw:FcSanPc:portId managed object property

cfprApSwFcSanPcPortVsanId

1.3.6.1.4.1.9.9.826.2.1.75.50.1.15

Gauge32

Cisco Firepower sw:FcSanPc:portVsanId managed object property

cfprApSwFcSanPcSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.50.1.16

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:FcSanPc:switchId managed object property

cfprApSwFcSanPcTransport

1.3.6.1.4.1.9.9.826.2.1.75.50.1.17

CfprApSwFcSanPcTransport · BITS

Cisco Firepower sw:FcSanPc:transport managed object property

cfprApSwFcSanPcType

1.3.6.1.4.1.9.9.826.2.1.75.50.1.18

CfprApSwSanPcType · BITS

Cisco Firepower sw:FcSanPc:type managed object property

cfprApSwFcServerZoneGroupTable

1.3.6.1.4.1.9.9.826.2.1.75.51

Index: cfprApSwFcServerZoneGroupInstanceId

Cisco Firepower sw:FcServerZoneGroup managed object table

cfprApSwFcServerZoneGroupInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.51.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcServerZoneGroupDn

1.3.6.1.4.1.9.9.826.2.1.75.51.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcServerZoneGroup:dn managed object property

cfprApSwFcServerZoneGroupRn

1.3.6.1.4.1.9.9.826.2.1.75.51.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcServerZoneGroup:rn managed object property

cfprApSwFcServerZoneGroupEpDn

1.3.6.1.4.1.9.9.826.2.1.75.51.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcServerZoneGroup:epDn managed object property

cfprApSwFcServerZoneGroupId

1.3.6.1.4.1.9.9.826.2.1.75.51.1.5

Gauge32

Cisco Firepower sw:FcServerZoneGroup:id managed object property

cfprApSwFcServerZoneGroupLc

1.3.6.1.4.1.9.9.826.2.1.75.51.1.6

CfprApSwFcServerZoneGroupLc0 = available1 = allocated2 = deallocated3 = repurposed · Integer32

Cisco Firepower sw:FcServerZoneGroup:lc managed object property

cfprApSwFcServerZoneGroupName

1.3.6.1.4.1.9.9.826.2.1.75.51.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcServerZoneGroup:name managed object property

cfprApSwFcServerZoneGroupPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.51.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcServerZoneGroup:peerDn managed object property

cfprApSwFcServerZoneGroupServerDn

1.3.6.1.4.1.9.9.826.2.1.75.51.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcServerZoneGroup:serverDn managed object property

cfprApSwFcZoneTable

1.3.6.1.4.1.9.9.826.2.1.75.52

Index: cfprApSwFcZoneInstanceId

Cisco Firepower sw:FcZone managed object table

cfprApSwFcZoneInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.52.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcZoneDn

1.3.6.1.4.1.9.9.826.2.1.75.52.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcZone:dn managed object property

cfprApSwFcZoneRn

1.3.6.1.4.1.9.9.826.2.1.75.52.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZone:rn managed object property

cfprApSwFcZoneId

1.3.6.1.4.1.9.9.826.2.1.75.52.1.4

Gauge32

Cisco Firepower sw:FcZone:id managed object property

cfprApSwFcZoneIdentity

1.3.6.1.4.1.9.9.826.2.1.75.52.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZone:identity managed object property

cfprApSwFcZoneLc

1.3.6.1.4.1.9.9.826.2.1.75.52.1.6

CfprApSwFcZoneLc0 = available1 = allocated2 = deallocated3 = repurposed · Integer32

Cisco Firepower sw:FcZone:lc managed object property

cfprApSwFcZoneName

1.3.6.1.4.1.9.9.826.2.1.75.52.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZone:name managed object property

cfprApSwFcZoneOperState

1.3.6.1.4.1.9.9.826.2.1.75.52.1.8

CfprApLsFcZoneState0 = notApplied1 = applied2 = applying3 = applyPending4 = notActive5 = active6 = created7 = createFailed8 = deleted9 = zoneMergeFailure · Integer32

Cisco Firepower sw:FcZone:operState managed object property

cfprApSwFcZonePeerDn

1.3.6.1.4.1.9.9.826.2.1.75.52.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZone:peerDn managed object property

cfprApSwFcZoneSetTable

1.3.6.1.4.1.9.9.826.2.1.75.53

Index: cfprApSwFcZoneSetInstanceId

Cisco Firepower sw:FcZoneSet managed object table

cfprApSwFcZoneSetInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.53.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcZoneSetDn

1.3.6.1.4.1.9.9.826.2.1.75.53.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcZoneSet:dn managed object property

cfprApSwFcZoneSetRn

1.3.6.1.4.1.9.9.826.2.1.75.53.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZoneSet:rn managed object property

cfprApSwFcZoneSetCurrentZonePrefix

1.3.6.1.4.1.9.9.826.2.1.75.53.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZoneSet:currentZonePrefix managed object property

cfprApSwFcZoneSetLc

1.3.6.1.4.1.9.9.826.2.1.75.53.1.5

CfprApSwFcZoneSetLc0 = available1 = allocated2 = deallocated3 = repurposed · Integer32

Cisco Firepower sw:FcZoneSet:lc managed object property

cfprApSwFcZoneSetName

1.3.6.1.4.1.9.9.826.2.1.75.53.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZoneSet:name managed object property

cfprApSwFcZoneSetOldZonePrefix

1.3.6.1.4.1.9.9.826.2.1.75.53.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcZoneSet:oldZonePrefix managed object property

cfprApSwFcoeSanEpTable

1.3.6.1.4.1.9.9.826.2.1.75.55

Index: cfprApSwFcoeSanEpInstanceId

Cisco Firepower sw:FcoeSanEp managed object table

cfprApSwFcoeSanEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcoeSanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.55.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcoeSanEp:dn managed object property

cfprApSwFcoeSanEpRn

1.3.6.1.4.1.9.9.826.2.1.75.55.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanEp:rn managed object property

cfprApSwFcoeSanEpAdminSpeed

1.3.6.1.4.1.9.9.826.2.1.75.55.1.4

CfprApPortSpeed0 = indeterminate1 = n1gbps2 = n2gbps3 = n4gbps4 = n8gbps5 = auto · Integer32

Cisco Firepower sw:FcoeSanEp:adminSpeed managed object property

cfprApSwFcoeSanEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.55.1.5

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:FcoeSanEp:adminState managed object property

cfprApSwFcoeSanEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.6

Gauge32

Cisco Firepower sw:FcoeSanEp:aggrPortId managed object property

cfprApSwFcoeSanEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.7

Gauge32

Cisco Firepower sw:FcoeSanEp:chassisId managed object property

cfprApSwFcoeSanEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.55.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanEp:epDn managed object property

cfprApSwFcoeSanEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.55.1.9

CfprApSwSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:FcoeSanEp:ifRole managed object property

cfprApSwFcoeSanEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.55.1.10

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:FcoeSanEp:ifType managed object property

cfprApSwFcoeSanEpLc

1.3.6.1.4.1.9.9.826.2.1.75.55.1.11

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:FcoeSanEp:lc managed object property

cfprApSwFcoeSanEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.55.1.12

CfprApSwBorderEpLocale · BITS

Cisco Firepower sw:FcoeSanEp:locale managed object property

cfprApSwFcoeSanEpName

1.3.6.1.4.1.9.9.826.2.1.75.55.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanEp:name managed object property

cfprApSwFcoeSanEpPcId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.14

Gauge32

Cisco Firepower sw:FcoeSanEp:pcId managed object property

cfprApSwFcoeSanEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.15

Gauge32

Cisco Firepower sw:FcoeSanEp:peerAggrPortId managed object property

cfprApSwFcoeSanEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.16

Gauge32

Cisco Firepower sw:FcoeSanEp:peerChassisId managed object property

cfprApSwFcoeSanEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.55.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanEp:peerDn managed object property

cfprApSwFcoeSanEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.18

Gauge32

Cisco Firepower sw:FcoeSanEp:peerPortId managed object property

cfprApSwFcoeSanEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.19

Gauge32

Cisco Firepower sw:FcoeSanEp:peerSlotId managed object property

cfprApSwFcoeSanEpPeerState

1.3.6.1.4.1.9.9.826.2.1.75.55.1.20

CfprApSwPeerStatus1 = existing2 = nonexisting · Integer32

Cisco Firepower sw:FcoeSanEp:peerState managed object property

cfprApSwFcoeSanEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.21

Gauge32

Cisco Firepower sw:FcoeSanEp:portId managed object property

cfprApSwFcoeSanEpPortVsanId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.22

Gauge32

Cisco Firepower sw:FcoeSanEp:portVsanId managed object property

cfprApSwFcoeSanEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.23

Gauge32

Cisco Firepower sw:FcoeSanEp:slotId managed object property

cfprApSwFcoeSanEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.55.1.24

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:FcoeSanEp:switchId managed object property

cfprApSwFcoeSanEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.55.1.25

CfprApSwFcoeSanEpTransport · BITS

Cisco Firepower sw:FcoeSanEp:transport managed object property

cfprApSwFcoeSanEpType

1.3.6.1.4.1.9.9.826.2.1.75.55.1.26

CfprApSwSanEpType · BITS

Cisco Firepower sw:FcoeSanEp:type managed object property

cfprApSwFcoeSanEpUdldAdminState

1.3.6.1.4.1.9.9.826.2.1.75.55.1.27

CfprApSwFcoeSanEpUdldAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:FcoeSanEp:udldAdminState managed object property

cfprApSwFcoeSanEpUdldMode

1.3.6.1.4.1.9.9.826.2.1.75.55.1.28

CfprApSwFcoeSanEpUdldMode0 = normal1 = aggressive · Integer32

Cisco Firepower sw:FcoeSanEp:udldMode managed object property

cfprApSwFcoeSanPcTable

1.3.6.1.4.1.9.9.826.2.1.75.56

Index: cfprApSwFcoeSanPcInstanceId

Cisco Firepower sw:FcoeSanPc managed object table

cfprApSwFcoeSanPcInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.56.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwFcoeSanPcDn

1.3.6.1.4.1.9.9.826.2.1.75.56.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:FcoeSanPc:dn managed object property

cfprApSwFcoeSanPcRn

1.3.6.1.4.1.9.9.826.2.1.75.56.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanPc:rn managed object property

cfprApSwFcoeSanPcAdminState

1.3.6.1.4.1.9.9.826.2.1.75.56.1.4

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:FcoeSanPc:adminState managed object property

cfprApSwFcoeSanPcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.56.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanPc:epDn managed object property

cfprApSwFcoeSanPcIfRole

1.3.6.1.4.1.9.9.826.2.1.75.56.1.6

CfprApSwSanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:FcoeSanPc:ifRole managed object property

cfprApSwFcoeSanPcIfType

1.3.6.1.4.1.9.9.826.2.1.75.56.1.7

CfprApSwCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:FcoeSanPc:ifType managed object property

cfprApSwFcoeSanPcLacpFastTimer

1.3.6.1.4.1.9.9.826.2.1.75.56.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:FcoeSanPc:lacpFastTimer managed object property

cfprApSwFcoeSanPcLacpSuspendIndividual

1.3.6.1.4.1.9.9.826.2.1.75.56.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:FcoeSanPc:lacpSuspendIndividual managed object property

cfprApSwFcoeSanPcLocale

1.3.6.1.4.1.9.9.826.2.1.75.56.1.10

CfprApSwBorderPcLocale · BITS

Cisco Firepower sw:FcoeSanPc:locale managed object property

cfprApSwFcoeSanPcMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.56.1.11

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:FcoeSanPc:monTrafDir managed object property

cfprApSwFcoeSanPcName

1.3.6.1.4.1.9.9.826.2.1.75.56.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanPc:name managed object property

cfprApSwFcoeSanPcPcId

1.3.6.1.4.1.9.9.826.2.1.75.56.1.13

Gauge32

Cisco Firepower sw:FcoeSanPc:pcId managed object property

cfprApSwFcoeSanPcPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.56.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:FcoeSanPc:peerDn managed object property

cfprApSwFcoeSanPcPeerState

1.3.6.1.4.1.9.9.826.2.1.75.56.1.15

CfprApSwPeerStatus1 = existing2 = nonexisting · Integer32

Cisco Firepower sw:FcoeSanPc:peerState managed object property

cfprApSwFcoeSanPcPortId

1.3.6.1.4.1.9.9.826.2.1.75.56.1.16

Gauge32

Cisco Firepower sw:FcoeSanPc:portId managed object property

cfprApSwFcoeSanPcPortVsanId

1.3.6.1.4.1.9.9.826.2.1.75.56.1.17

Gauge32

Cisco Firepower sw:FcoeSanPc:portVsanId managed object property

cfprApSwFcoeSanPcSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.56.1.18

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:FcoeSanPc:switchId managed object property

cfprApSwFcoeSanPcTransport

1.3.6.1.4.1.9.9.826.2.1.75.56.1.19

CfprApSwFcoeSanPcTransport · BITS

Cisco Firepower sw:FcoeSanPc:transport managed object property

cfprApSwFcoeSanPcType

1.3.6.1.4.1.9.9.826.2.1.75.56.1.20

CfprApSwSanPcType · BITS

Cisco Firepower sw:FcoeSanPc:type managed object property

cfprApSwPhysTable

1.3.6.1.4.1.9.9.826.2.1.75.64

Index: cfprApSwPhysInstanceId

Cisco Firepower sw:Phys managed object table

cfprApSwPhysInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.64.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPhysDn

1.3.6.1.4.1.9.9.826.2.1.75.64.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:Phys:dn managed object property

cfprApSwPhysRn

1.3.6.1.4.1.9.9.826.2.1.75.64.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Phys:rn managed object property

cfprApSwPhysConfMode

1.3.6.1.4.1.9.9.826.2.1.75.64.1.4

CfprApSwConfMode0 = none1 = inProgress2 = verifying3 = failed · Integer32

Cisco Firepower sw:Phys:confMode managed object property

cfprApSwPhysFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.64.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Phys:fsmDescr managed object property

cfprApSwPhysFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.64.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Phys:fsmPrev managed object property

cfprApSwPhysFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.64.1.7

Gauge32

Cisco Firepower sw:Phys:fsmProgr managed object property

cfprApSwPhysFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.64.1.8

Gauge32

Cisco Firepower sw:Phys:fsmRmtInvErrCode managed object property

cfprApSwPhysFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.64.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Phys:fsmRmtInvErrDescr managed object property

cfprApSwPhysFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.64.1.10

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:Phys:fsmRmtInvRslt managed object property

cfprApSwPhysFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.64.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Phys:fsmStageDescr managed object property

cfprApSwPhysFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.64.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:Phys:fsmStamp managed object property

cfprApSwPhysFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.64.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Phys:fsmStatus managed object property

cfprApSwPhysFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.64.1.14

Gauge32

Cisco Firepower sw:Phys:fsmTry managed object property

cfprApSwPhysEtherEpTable

1.3.6.1.4.1.9.9.826.2.1.75.65

Index: cfprApSwPhysEtherEpInstanceId

Cisco Firepower sw:PhysEtherEp managed object table

cfprApSwPhysEtherEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPhysEtherEpDn

1.3.6.1.4.1.9.9.826.2.1.75.65.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:PhysEtherEp:dn managed object property

cfprApSwPhysEtherEpRn

1.3.6.1.4.1.9.9.826.2.1.75.65.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysEtherEp:rn managed object property

cfprApSwPhysEtherEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.65.1.4

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:PhysEtherEp:adminState managed object property

cfprApSwPhysEtherEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.5

Gauge32

Cisco Firepower sw:PhysEtherEp:aggrPortId managed object property

cfprApSwPhysEtherEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.6

Gauge32

Cisco Firepower sw:PhysEtherEp:chassisId managed object property

cfprApSwPhysEtherEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.65.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysEtherEp:epDn managed object property

cfprApSwPhysEtherEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.65.1.8

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:PhysEtherEp:ifRole managed object property

cfprApSwPhysEtherEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.65.1.9

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:PhysEtherEp:ifType managed object property

cfprApSwPhysEtherEpLc

1.3.6.1.4.1.9.9.826.2.1.75.65.1.10

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:PhysEtherEp:lc managed object property

cfprApSwPhysEtherEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.65.1.11

CfprApNetworkLocale · BITS

Cisco Firepower sw:PhysEtherEp:locale managed object property

cfprApSwPhysEtherEpName

1.3.6.1.4.1.9.9.826.2.1.75.65.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysEtherEp:name managed object property

cfprApSwPhysEtherEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.13

Gauge32

Cisco Firepower sw:PhysEtherEp:peerAggrPortId managed object property

cfprApSwPhysEtherEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.14

Gauge32

Cisco Firepower sw:PhysEtherEp:peerChassisId managed object property

cfprApSwPhysEtherEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.65.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysEtherEp:peerDn managed object property

cfprApSwPhysEtherEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.16

Gauge32

Cisco Firepower sw:PhysEtherEp:peerPortId managed object property

cfprApSwPhysEtherEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.17

Gauge32

Cisco Firepower sw:PhysEtherEp:peerSlotId managed object property

cfprApSwPhysEtherEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.18

Gauge32

Cisco Firepower sw:PhysEtherEp:portId managed object property

cfprApSwPhysEtherEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.19

Gauge32

Cisco Firepower sw:PhysEtherEp:slotId managed object property

cfprApSwPhysEtherEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.65.1.20

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:PhysEtherEp:switchId managed object property

cfprApSwPhysEtherEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.65.1.21

CfprApNetworkTransport · BITS

Cisco Firepower sw:PhysEtherEp:transport managed object property

cfprApSwPhysEtherEpType

1.3.6.1.4.1.9.9.826.2.1.75.65.1.22

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:PhysEtherEp:type managed object property

cfprApSwPhysFcEpTable

1.3.6.1.4.1.9.9.826.2.1.75.66

Index: cfprApSwPhysFcEpInstanceId

Cisco Firepower sw:PhysFcEp managed object table

cfprApSwPhysFcEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPhysFcEpDn

1.3.6.1.4.1.9.9.826.2.1.75.66.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:PhysFcEp:dn managed object property

cfprApSwPhysFcEpRn

1.3.6.1.4.1.9.9.826.2.1.75.66.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFcEp:rn managed object property

cfprApSwPhysFcEpAdminState

1.3.6.1.4.1.9.9.826.2.1.75.66.1.4

CfprApFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:PhysFcEp:adminState managed object property

cfprApSwPhysFcEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.5

Gauge32

Cisco Firepower sw:PhysFcEp:aggrPortId managed object property

cfprApSwPhysFcEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.6

Gauge32

Cisco Firepower sw:PhysFcEp:chassisId managed object property

cfprApSwPhysFcEpEpDn

1.3.6.1.4.1.9.9.826.2.1.75.66.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFcEp:epDn managed object property

cfprApSwPhysFcEpIfRole

1.3.6.1.4.1.9.9.826.2.1.75.66.1.8

CfprApNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:PhysFcEp:ifRole managed object property

cfprApSwPhysFcEpIfType

1.3.6.1.4.1.9.9.826.2.1.75.66.1.9

CfprApSwPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:PhysFcEp:ifType managed object property

cfprApSwPhysFcEpLc

1.3.6.1.4.1.9.9.826.2.1.75.66.1.10

CfprApSwPIoEpLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending · Integer32

Cisco Firepower sw:PhysFcEp:lc managed object property

cfprApSwPhysFcEpLocale

1.3.6.1.4.1.9.9.826.2.1.75.66.1.11

CfprApNetworkLocale · BITS

Cisco Firepower sw:PhysFcEp:locale managed object property

cfprApSwPhysFcEpName

1.3.6.1.4.1.9.9.826.2.1.75.66.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFcEp:name managed object property

cfprApSwPhysFcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.13

Gauge32

Cisco Firepower sw:PhysFcEp:peerAggrPortId managed object property

cfprApSwPhysFcEpPeerChassisId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.14

Gauge32

Cisco Firepower sw:PhysFcEp:peerChassisId managed object property

cfprApSwPhysFcEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.66.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFcEp:peerDn managed object property

cfprApSwPhysFcEpPeerPortId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.16

Gauge32

Cisco Firepower sw:PhysFcEp:peerPortId managed object property

cfprApSwPhysFcEpPeerSlotId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.17

Gauge32

Cisco Firepower sw:PhysFcEp:peerSlotId managed object property

cfprApSwPhysFcEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.18

Gauge32

Cisco Firepower sw:PhysFcEp:portId managed object property

cfprApSwPhysFcEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.19

Gauge32

Cisco Firepower sw:PhysFcEp:slotId managed object property

cfprApSwPhysFcEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.66.1.20

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:PhysFcEp:switchId managed object property

cfprApSwPhysFcEpTransport

1.3.6.1.4.1.9.9.826.2.1.75.66.1.21

CfprApNetworkTransport · BITS

Cisco Firepower sw:PhysFcEp:transport managed object property

cfprApSwPhysFcEpType

1.3.6.1.4.1.9.9.826.2.1.75.66.1.22

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:PhysFcEp:type managed object property

cfprApSwPhysFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.67

Index: cfprApSwPhysFsmInstanceId

Cisco Firepower sw:PhysFsm managed object table

cfprApSwPhysFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.67.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPhysFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.67.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:PhysFsm:dn managed object property

cfprApSwPhysFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.67.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFsm:rn managed object property

cfprApSwPhysFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.67.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:PhysFsm:completionTime managed object property

cfprApSwPhysFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.67.1.5

CfprApSwPhysFsmCurrentFsm0 = nop106 = confPhysical · Integer32

Cisco Firepower sw:PhysFsm:currentFsm managed object property

cfprApSwPhysFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.67.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFsm:descr managed object property

cfprApSwPhysFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.67.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:PhysFsm:fsmStatus managed object property

cfprApSwPhysFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.67.1.8

Gauge32

Cisco Firepower sw:PhysFsm:progress managed object property

cfprApSwPhysFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.67.1.9

Gauge32

Cisco Firepower sw:PhysFsm:rmtErrCode managed object property

cfprApSwPhysFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.67.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFsm:rmtErrDescr managed object property

cfprApSwPhysFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.67.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:PhysFsm:rmtRslt managed object property

cfprApSwPhysFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.68

Index: cfprApSwPhysFsmStageInstanceId

Cisco Firepower sw:PhysFsmStage managed object table

cfprApSwPhysFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.68.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPhysFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.68.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:PhysFsmStage:dn managed object property

cfprApSwPhysFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.68.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFsmStage:rn managed object property

cfprApSwPhysFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.68.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFsmStage:descr managed object property

cfprApSwPhysFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.68.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:PhysFsmStage:lastUpdateTime managed object property

cfprApSwPhysFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.68.1.6

CfprApSwPhysFsmStageName0 = nop106 = confPhysicalBegin107 = confPhysicalPortInventorySwA108 = confPhysicalPortInventorySwB109 = confPhysicalConfigSwA110 = confPhysicalConfigSwB111 = confPhysicalVerifyPhysConfig112 = confPhysicalSuccess113 = confPhysicalFail · Integer32

Cisco Firepower sw:PhysFsmStage:name managed object property

cfprApSwPhysFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.68.1.7

Gauge32

Cisco Firepower sw:PhysFsmStage:order managed object property

cfprApSwPhysFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.68.1.8

Gauge32

Cisco Firepower sw:PhysFsmStage:retry managed object property

cfprApSwPhysFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.68.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:PhysFsmStage:stageStatus managed object property

cfprApSwPhysFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.69

Index: cfprApSwPhysFsmTaskInstanceId

Cisco Firepower sw:PhysFsmTask managed object table

cfprApSwPhysFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.69.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPhysFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.69.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:PhysFsmTask:dn managed object property

cfprApSwPhysFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.69.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PhysFsmTask:rn managed object property

cfprApSwPhysFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.69.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:PhysFsmTask:completion managed object property

cfprApSwPhysFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.69.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:PhysFsmTask:flags managed object property

cfprApSwPhysFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.69.1.6

CfprApSwPhysFsmTaskItem0 = nop106 = confPhysical · Integer32

Cisco Firepower sw:PhysFsmTask:item managed object property

cfprApSwPhysFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.69.1.7

Gauge32

Cisco Firepower sw:PhysFsmTask:seqId managed object property

cfprApSwPortBreakoutTable

1.3.6.1.4.1.9.9.826.2.1.75.70

Index: cfprApSwPortBreakoutInstanceId

Cisco Firepower sw:PortBreakout managed object table

cfprApSwPortBreakoutInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.70.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwPortBreakoutDn

1.3.6.1.4.1.9.9.826.2.1.75.70.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:PortBreakout:dn managed object property

cfprApSwPortBreakoutRn

1.3.6.1.4.1.9.9.826.2.1.75.70.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:PortBreakout:rn managed object property

cfprApSwPortBreakoutBreakoutType

1.3.6.1.4.1.9.9.826.2.1.75.70.1.4

CfprApSwBreakoutType0 = unknown1 = n10g4x · Integer32

Cisco Firepower sw:PortBreakout:breakoutType managed object property

cfprApSwPortBreakoutPortId

1.3.6.1.4.1.9.9.826.2.1.75.70.1.5

CfprApSwPortBreakoutPortId (1..4) · Gauge32

Cisco Firepower sw:PortBreakout:portId managed object property

cfprApSwPortBreakoutSlotId

1.3.6.1.4.1.9.9.826.2.1.75.70.1.6

CfprApSwPortBreakoutSlotId (2..3) · Gauge32

Cisco Firepower sw:PortBreakout:slotId managed object property

cfprApSwSspEthLanMonTable

1.3.6.1.4.1.9.9.826.2.1.75.71

Index: cfprApSwSspEthLanMonInstanceId

Cisco Firepower sw:SspEthLanMon managed object table

cfprApSwSspEthLanMonInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.71.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthLanMonDn

1.3.6.1.4.1.9.9.826.2.1.75.71.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthLanMon:dn managed object property

cfprApSwSspEthLanMonRn

1.3.6.1.4.1.9.9.826.2.1.75.71.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthLanMon:rn managed object property

cfprApSwSspEthLanMonLocale

1.3.6.1.4.1.9.9.826.2.1.75.71.1.4

CfprApSwSspMonDomainLocale · BITS

Cisco Firepower sw:SspEthLanMon:locale managed object property

cfprApSwSspEthLanMonName

1.3.6.1.4.1.9.9.826.2.1.75.71.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthLanMon:name managed object property

cfprApSwSspEthLanMonSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.71.1.6

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:SspEthLanMon:switchId managed object property

cfprApSwSspEthLanMonTransport

1.3.6.1.4.1.9.9.826.2.1.75.71.1.7

CfprApSwSspEthLanMonTransport · BITS

Cisco Firepower sw:SspEthLanMon:transport managed object property

cfprApSwSspEthLanMonType

1.3.6.1.4.1.9.9.826.2.1.75.71.1.8

CfprApSwSspLanMonType · BITS

Cisco Firepower sw:SspEthLanMon:type managed object property

cfprApSwSspEthMonTable

1.3.6.1.4.1.9.9.826.2.1.75.72

Index: cfprApSwSspEthMonInstanceId

Cisco Firepower sw:SspEthMon managed object table

cfprApSwSspEthMonInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.72.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonDn

1.3.6.1.4.1.9.9.826.2.1.75.72.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMon:dn managed object property

cfprApSwSspEthMonRn

1.3.6.1.4.1.9.9.826.2.1.75.72.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:rn managed object property

cfprApSwSspEthMonAdminState

1.3.6.1.4.1.9.9.826.2.1.75.72.1.4

CfprApSwSspMonAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower sw:SspEthMon:adminState managed object property

cfprApSwSspEthMonAppendFlag

1.3.6.1.4.1.9.9.826.2.1.75.72.1.5

CfprApFabricPktCaptureAppendFlag1 = append2 = overwrite · Integer32

Cisco Firepower sw:SspEthMon:appendFlag managed object property

cfprApSwSspEthMonDelPcap

1.3.6.1.4.1.9.9.826.2.1.75.72.1.6

CfprApSwSspMonDelPcap1 = enabled2 = disabled · Integer32

Cisco Firepower sw:SspEthMon:delPcap managed object property

cfprApSwSspEthMonFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.72.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:fsmDescr managed object property

cfprApSwSspEthMonFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.72.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:fsmPrev managed object property

cfprApSwSspEthMonFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.72.1.9

Gauge32

Cisco Firepower sw:SspEthMon:fsmProgr managed object property

cfprApSwSspEthMonFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.72.1.10

Gauge32

Cisco Firepower sw:SspEthMon:fsmRmtInvErrCode managed object property

cfprApSwSspEthMonFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.72.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:fsmRmtInvErrDescr managed object property

cfprApSwSspEthMonFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.72.1.12

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:SspEthMon:fsmRmtInvRslt managed object property

cfprApSwSspEthMonFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.72.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:fsmStageDescr managed object property

cfprApSwSspEthMonFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.72.1.14

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SspEthMon:fsmStamp managed object property

cfprApSwSspEthMonFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.72.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:fsmStatus managed object property

cfprApSwSspEthMonFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.72.1.16

Gauge32

Cisco Firepower sw:SspEthMon:fsmTry managed object property

cfprApSwSspEthMonLifeCycle

1.3.6.1.4.1.9.9.826.2.1.75.72.1.17

CfprApSwPktCaptureLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower sw:SspEthMon:lifeCycle managed object property

cfprApSwSspEthMonName

1.3.6.1.4.1.9.9.826.2.1.75.72.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:name managed object property

cfprApSwSspEthMonPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.72.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMon:peerDn managed object property

cfprApSwSspEthMonSession

1.3.6.1.4.1.9.9.826.2.1.75.72.1.20

Gauge32

Cisco Firepower sw:SspEthMon:session managed object property

cfprApSwSspEthMonSessionMemUsage

1.3.6.1.4.1.9.9.826.2.1.75.72.1.21

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:SspEthMon:sessionMemUsage managed object property

cfprApSwSspEthMonSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.72.1.22

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:SspEthMon:switchId managed object property

cfprApSwSspEthMonTransport

1.3.6.1.4.1.9.9.826.2.1.75.72.1.23

CfprApSwSspEthMonTransport · BITS

Cisco Firepower sw:SspEthMon:transport managed object property

cfprApSwSspEthMonType

1.3.6.1.4.1.9.9.826.2.1.75.72.1.24

CfprApSwSspEthMonType · BITS

Cisco Firepower sw:SspEthMon:type managed object property

cfprApSwSspEthMonFilterEpTable

1.3.6.1.4.1.9.9.826.2.1.75.73

Index: cfprApSwSspEthMonFilterEpInstanceId

Cisco Firepower sw:SspEthMonFilterEp managed object table

cfprApSwSspEthMonFilterEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.73.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonFilterEpDn

1.3.6.1.4.1.9.9.826.2.1.75.73.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonFilterEp:dn managed object property

cfprApSwSspEthMonFilterEpRn

1.3.6.1.4.1.9.9.826.2.1.75.73.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFilterEp:rn managed object property

cfprApSwSspEthMonFilterEpDestIp

1.3.6.1.4.1.9.9.826.2.1.75.73.1.4

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower sw:SspEthMonFilterEp:destIp managed object property

cfprApSwSspEthMonFilterEpDestMAC

1.3.6.1.4.1.9.9.826.2.1.75.73.1.5

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower sw:SspEthMonFilterEp:destMAC managed object property

cfprApSwSspEthMonFilterEpDestPort

1.3.6.1.4.1.9.9.826.2.1.75.73.1.6

CfprApFabricPort (0..65535) · Gauge32

Cisco Firepower sw:SspEthMonFilterEp:destPort managed object property

cfprApSwSspEthMonFilterEpEthertype

1.3.6.1.4.1.9.9.826.2.1.75.73.1.7

Gauge32

Cisco Firepower sw:SspEthMonFilterEp:ethertype managed object property

cfprApSwSspEthMonFilterEpFilterFlag

1.3.6.1.4.1.9.9.826.2.1.75.73.1.8

Gauge32

Cisco Firepower sw:SspEthMonFilterEp:filterFlag managed object property

cfprApSwSspEthMonFilterEpIvlan

1.3.6.1.4.1.9.9.826.2.1.75.73.1.9

Gauge32

Cisco Firepower sw:SspEthMonFilterEp:ivlan managed object property

cfprApSwSspEthMonFilterEpLifeCycle

1.3.6.1.4.1.9.9.826.2.1.75.73.1.10

CfprApSwPktCaptureLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower sw:SspEthMonFilterEp:lifeCycle managed object property

cfprApSwSspEthMonFilterEpNameId

1.3.6.1.4.1.9.9.826.2.1.75.73.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFilterEp:nameId managed object property

cfprApSwSspEthMonFilterEpOvlan

1.3.6.1.4.1.9.9.826.2.1.75.73.1.12

Gauge32

Cisco Firepower sw:SspEthMonFilterEp:ovlan managed object property

cfprApSwSspEthMonFilterEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.73.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFilterEp:peerDn managed object property

cfprApSwSspEthMonFilterEpProtocol

1.3.6.1.4.1.9.9.826.2.1.75.73.1.14

Gauge32

Cisco Firepower sw:SspEthMonFilterEp:protocol managed object property

cfprApSwSspEthMonFilterEpRefCount

1.3.6.1.4.1.9.9.826.2.1.75.73.1.15

Gauge32

Cisco Firepower sw:SspEthMonFilterEp:refCount managed object property

cfprApSwSspEthMonFilterEpSrcIp

1.3.6.1.4.1.9.9.826.2.1.75.73.1.16

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower sw:SspEthMonFilterEp:srcIp managed object property

cfprApSwSspEthMonFilterEpSrcMAC

1.3.6.1.4.1.9.9.826.2.1.75.73.1.17

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower sw:SspEthMonFilterEp:srcMAC managed object property

cfprApSwSspEthMonFilterEpSrcPort

1.3.6.1.4.1.9.9.826.2.1.75.73.1.18

CfprApFabricPort (0..65535) · Gauge32

Cisco Firepower sw:SspEthMonFilterEp:srcPort managed object property

cfprApSwSspEthMonFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.74

Index: cfprApSwSspEthMonFsmInstanceId

Cisco Firepower sw:SspEthMonFsm managed object table

cfprApSwSspEthMonFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.74.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.74.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonFsm:dn managed object property

cfprApSwSspEthMonFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.74.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFsm:rn managed object property

cfprApSwSspEthMonFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.74.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SspEthMonFsm:completionTime managed object property

cfprApSwSspEthMonFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.74.1.5

CfprApSwSspEthMonFsmCurrentFsm0 = nop443 = deploy · Integer32

Cisco Firepower sw:SspEthMonFsm:currentFsm managed object property

cfprApSwSspEthMonFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.74.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFsm:descr managed object property

cfprApSwSspEthMonFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.74.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:SspEthMonFsm:fsmStatus managed object property

cfprApSwSspEthMonFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.74.1.8

Gauge32

Cisco Firepower sw:SspEthMonFsm:progress managed object property

cfprApSwSspEthMonFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.74.1.9

Gauge32

Cisco Firepower sw:SspEthMonFsm:rmtErrCode managed object property

cfprApSwSspEthMonFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.74.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFsm:rmtErrDescr managed object property

cfprApSwSspEthMonFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.74.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:SspEthMonFsm:rmtRslt managed object property

cfprApSwSspEthMonFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.75

Index: cfprApSwSspEthMonFsmStageInstanceId

Cisco Firepower sw:SspEthMonFsmStage managed object table

cfprApSwSspEthMonFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.75.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.75.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonFsmStage:dn managed object property

cfprApSwSspEthMonFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.75.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFsmStage:rn managed object property

cfprApSwSspEthMonFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.75.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFsmStage:descr managed object property

cfprApSwSspEthMonFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.75.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SspEthMonFsmStage:lastUpdateTime managed object property

cfprApSwSspEthMonFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.75.1.6

CfprApSwSspEthMonFsmStageName0 = nop443 = deployBegin444 = deployUpdateSspEthMon800 = deployFail801 = deploySuccess · Integer32

Cisco Firepower sw:SspEthMonFsmStage:name managed object property

cfprApSwSspEthMonFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.75.1.7

Gauge32

Cisco Firepower sw:SspEthMonFsmStage:order managed object property

cfprApSwSspEthMonFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.75.1.8

Gauge32

Cisco Firepower sw:SspEthMonFsmStage:retry managed object property

cfprApSwSspEthMonFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.75.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:SspEthMonFsmStage:stageStatus managed object property

cfprApSwSspEthMonFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.76

Index: cfprApSwSspEthMonFsmTaskInstanceId

Cisco Firepower sw:SspEthMonFsmTask managed object table

cfprApSwSspEthMonFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.76.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.76.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonFsmTask:dn managed object property

cfprApSwSspEthMonFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.76.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonFsmTask:rn managed object property

cfprApSwSspEthMonFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.76.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:SspEthMonFsmTask:completion managed object property

cfprApSwSspEthMonFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.76.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:SspEthMonFsmTask:flags managed object property

cfprApSwSspEthMonFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.76.1.6

CfprApSwSspEthMonFsmTaskItem0 = nop443 = deploy · Integer32

Cisco Firepower sw:SspEthMonFsmTask:item managed object property

cfprApSwSspEthMonFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.76.1.7

Gauge32

Cisco Firepower sw:SspEthMonFsmTask:seqId managed object property

cfprApSwSspEthMonSrcAppEpTable

1.3.6.1.4.1.9.9.826.2.1.75.77

Index: cfprApSwSspEthMonSrcAppEpInstanceId

Cisco Firepower sw:SspEthMonSrcAppEp managed object table

cfprApSwSspEthMonSrcAppEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.77.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonSrcAppEpDn

1.3.6.1.4.1.9.9.826.2.1.75.77.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonSrcAppEp:dn managed object property

cfprApSwSspEthMonSrcAppEpRn

1.3.6.1.4.1.9.9.826.2.1.75.77.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:rn managed object property

cfprApSwSspEthMonSrcAppEpAppName

1.3.6.1.4.1.9.9.826.2.1.75.77.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:appName managed object property

cfprApSwSspEthMonSrcAppEpExternalPortDn

1.3.6.1.4.1.9.9.826.2.1.75.77.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:externalPortDn managed object property

cfprApSwSspEthMonSrcAppEpFilter

1.3.6.1.4.1.9.9.826.2.1.75.77.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:filter managed object property

cfprApSwSspEthMonSrcAppEpFilterDn

1.3.6.1.4.1.9.9.826.2.1.75.77.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:filterDn managed object property

cfprApSwSspEthMonSrcAppEpLifeCycle

1.3.6.1.4.1.9.9.826.2.1.75.77.1.8

CfprApSwPktCaptureLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower sw:SspEthMonSrcAppEp:lifeCycle managed object property

cfprApSwSspEthMonSrcAppEpLinkName

1.3.6.1.4.1.9.9.826.2.1.75.77.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:linkName managed object property

cfprApSwSspEthMonSrcAppEpPcapfile

1.3.6.1.4.1.9.9.826.2.1.75.77.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:pcapfile managed object property

cfprApSwSspEthMonSrcAppEpPcapfilename

1.3.6.1.4.1.9.9.826.2.1.75.77.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:pcapfilename managed object property

cfprApSwSspEthMonSrcAppEpPcapsize

1.3.6.1.4.1.9.9.826.2.1.75.77.1.12

Gauge32

Cisco Firepower sw:SspEthMonSrcAppEp:pcapsize managed object property

cfprApSwSspEthMonSrcAppEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.77.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:peerDn managed object property

cfprApSwSspEthMonSrcAppEpPortChannelDn

1.3.6.1.4.1.9.9.826.2.1.75.77.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:portChannelDn managed object property

cfprApSwSspEthMonSrcAppEpPortName

1.3.6.1.4.1.9.9.826.2.1.75.77.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppEp:portName managed object property

cfprApSwSspEthMonSrcAppEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.77.1.16

Gauge32

Cisco Firepower sw:SspEthMonSrcAppEp:slotId managed object property

cfprApSwSspEthMonSrcAppLinksEpTable

1.3.6.1.4.1.9.9.826.2.1.75.78

Index: cfprApSwSspEthMonSrcAppLinksEpInstanceId

Cisco Firepower sw:SspEthMonSrcAppLinksEp managed object table

cfprApSwSspEthMonSrcAppLinksEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.78.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonSrcAppLinksEpDn

1.3.6.1.4.1.9.9.826.2.1.75.78.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonSrcAppLinksEp:dn managed object property

cfprApSwSspEthMonSrcAppLinksEpRn

1.3.6.1.4.1.9.9.826.2.1.75.78.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:rn managed object property

cfprApSwSspEthMonSrcAppLinksEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.78.1.4

Gauge32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:chassisId managed object property

cfprApSwSspEthMonSrcAppLinksEpEqAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.78.1.5

Gauge32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:eqAggrPortId managed object property

cfprApSwSspEthMonSrcAppLinksEpEqPortId

1.3.6.1.4.1.9.9.826.2.1.75.78.1.6

Gauge32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:eqPortId managed object property

cfprApSwSspEthMonSrcAppLinksEpEqSlotId

1.3.6.1.4.1.9.9.826.2.1.75.78.1.7

Gauge32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:eqSlotId managed object property

cfprApSwSspEthMonSrcAppLinksEpFilter

1.3.6.1.4.1.9.9.826.2.1.75.78.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:filter managed object property

cfprApSwSspEthMonSrcAppLinksEpFilterDn

1.3.6.1.4.1.9.9.826.2.1.75.78.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:filterDn managed object property

cfprApSwSspEthMonSrcAppLinksEpLifeCycle

1.3.6.1.4.1.9.9.826.2.1.75.78.1.10

CfprApSwPktCaptureLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:lifeCycle managed object property

cfprApSwSspEthMonSrcAppLinksEpName

1.3.6.1.4.1.9.9.826.2.1.75.78.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:name managed object property

cfprApSwSspEthMonSrcAppLinksEpPcapfile

1.3.6.1.4.1.9.9.826.2.1.75.78.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:pcapfile managed object property

cfprApSwSspEthMonSrcAppLinksEpPcapfilename

1.3.6.1.4.1.9.9.826.2.1.75.78.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:pcapfilename managed object property

cfprApSwSspEthMonSrcAppLinksEpPcapsize

1.3.6.1.4.1.9.9.826.2.1.75.78.1.14

Gauge32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:pcapsize managed object property

cfprApSwSspEthMonSrcAppLinksEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.78.1.15

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:switchId managed object property

cfprApSwSspEthMonSrcAppLinksEpVlan

1.3.6.1.4.1.9.9.826.2.1.75.78.1.16

Gauge32

Cisco Firepower sw:SspEthMonSrcAppLinksEp:vlan managed object property

cfprApSwSspEthMonSrcAppLinksEpVnicName1

1.3.6.1.4.1.9.9.826.2.1.75.78.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcAppLinksEp:vnicName1 managed object property

cfprApSwSspEthMonSrcPhyEpTable

1.3.6.1.4.1.9.9.826.2.1.75.79

Index: cfprApSwSspEthMonSrcPhyEpInstanceId

Cisco Firepower sw:SspEthMonSrcPhyEp managed object table

cfprApSwSspEthMonSrcPhyEpInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.79.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonSrcPhyEpDn

1.3.6.1.4.1.9.9.826.2.1.75.79.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonSrcPhyEp:dn managed object property

cfprApSwSspEthMonSrcPhyEpRn

1.3.6.1.4.1.9.9.826.2.1.75.79.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:rn managed object property

cfprApSwSspEthMonSrcPhyEpAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.79.1.4

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:aggrPortId managed object property

cfprApSwSspEthMonSrcPhyEpChassisId

1.3.6.1.4.1.9.9.826.2.1.75.79.1.5

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:chassisId managed object property

cfprApSwSspEthMonSrcPhyEpFilter

1.3.6.1.4.1.9.9.826.2.1.75.79.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:filter managed object property

cfprApSwSspEthMonSrcPhyEpFilterDn

1.3.6.1.4.1.9.9.826.2.1.75.79.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:filterDn managed object property

cfprApSwSspEthMonSrcPhyEpFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.79.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmDescr managed object property

cfprApSwSspEthMonSrcPhyEpFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.79.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmPrev managed object property

cfprApSwSspEthMonSrcPhyEpFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.79.1.10

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmProgr managed object property

cfprApSwSspEthMonSrcPhyEpFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.79.1.11

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmRmtInvErrCode managed object property

cfprApSwSspEthMonSrcPhyEpFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.79.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmRmtInvErrDescr managed object property

cfprApSwSspEthMonSrcPhyEpFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.79.1.13

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmRmtInvRslt managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.79.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmStageDescr managed object property

cfprApSwSspEthMonSrcPhyEpFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.79.1.15

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmStamp managed object property

cfprApSwSspEthMonSrcPhyEpFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.79.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmStatus managed object property

cfprApSwSspEthMonSrcPhyEpFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.79.1.17

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:fsmTry managed object property

cfprApSwSspEthMonSrcPhyEpLifeCycle

1.3.6.1.4.1.9.9.826.2.1.75.79.1.18

CfprApSwPktCaptureLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEp:lifeCycle managed object property

cfprApSwSspEthMonSrcPhyEpPcapfile

1.3.6.1.4.1.9.9.826.2.1.75.79.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:pcapfile managed object property

cfprApSwSspEthMonSrcPhyEpPcapfilename

1.3.6.1.4.1.9.9.826.2.1.75.79.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:pcapfilename managed object property

cfprApSwSspEthMonSrcPhyEpPcapsize

1.3.6.1.4.1.9.9.826.2.1.75.79.1.21

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:pcapsize managed object property

cfprApSwSspEthMonSrcPhyEpPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.79.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEp:peerDn managed object property

cfprApSwSspEthMonSrcPhyEpPortId

1.3.6.1.4.1.9.9.826.2.1.75.79.1.23

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:portId managed object property

cfprApSwSspEthMonSrcPhyEpSlotId

1.3.6.1.4.1.9.9.826.2.1.75.79.1.24

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEp:slotId managed object property

cfprApSwSspEthMonSrcPhyEpSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.79.1.25

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEp:switchId managed object property

cfprApSwSspEthMonSrcPhyEpFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.80

Index: cfprApSwSspEthMonSrcPhyEpFsmInstanceId

Cisco Firepower sw:SspEthMonSrcPhyEpFsm managed object table

cfprApSwSspEthMonSrcPhyEpFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.80.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonSrcPhyEpFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.80.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:dn managed object property

cfprApSwSspEthMonSrcPhyEpFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.80.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:rn managed object property

cfprApSwSspEthMonSrcPhyEpFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.80.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:completionTime managed object property

cfprApSwSspEthMonSrcPhyEpFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.80.1.5

CfprApSwSspEthMonSrcPhyEpFsmCurrentFsm0 = nop445 = delete · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:currentFsm managed object property

cfprApSwSspEthMonSrcPhyEpFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.80.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:descr managed object property

cfprApSwSspEthMonSrcPhyEpFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.80.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:fsmStatus managed object property

cfprApSwSspEthMonSrcPhyEpFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.80.1.8

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:progress managed object property

cfprApSwSspEthMonSrcPhyEpFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.80.1.9

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:rmtErrCode managed object property

cfprApSwSspEthMonSrcPhyEpFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.80.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:rmtErrDescr managed object property

cfprApSwSspEthMonSrcPhyEpFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.80.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:SspEthMonSrcPhyEpFsm:rmtRslt managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.81

Index: cfprApSwSspEthMonSrcPhyEpFsmStageInstanceId

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage managed object table

cfprApSwSspEthMonSrcPhyEpFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.81.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonSrcPhyEpFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.81.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:dn managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.81.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:rn managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.81.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:descr managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.81.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:lastUpdateTime managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.81.1.6

CfprApSwSspEthMonSrcPhyEpFsmStageName0 = nop445 = deleteBegin446 = deleteDeletePcapFile802 = deleteFail803 = deleteSuccess · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:name managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.81.1.7

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:order managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.81.1.8

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:retry managed object property

cfprApSwSspEthMonSrcPhyEpFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.81.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmStage:stageStatus managed object property

cfprApSwSspEthMonSrcPhyEpFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.82

Index: cfprApSwSspEthMonSrcPhyEpFsmTaskInstanceId

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask managed object table

cfprApSwSspEthMonSrcPhyEpFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.82.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSspEthMonSrcPhyEpFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.82.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask:dn managed object property

cfprApSwSspEthMonSrcPhyEpFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.82.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask:rn managed object property

cfprApSwSspEthMonSrcPhyEpFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.82.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask:completion managed object property

cfprApSwSspEthMonSrcPhyEpFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.82.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask:flags managed object property

cfprApSwSspEthMonSrcPhyEpFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.82.1.6

CfprApSwSspEthMonSrcPhyEpFsmTaskItem0 = nop445 = delete · Integer32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask:item managed object property

cfprApSwSspEthMonSrcPhyEpFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.82.1.7

Gauge32

Cisco Firepower sw:SspEthMonSrcPhyEpFsmTask:seqId managed object property

cfprApSwSubGroupTable

1.3.6.1.4.1.9.9.826.2.1.75.83

Index: cfprApSwSubGroupInstanceId

Cisco Firepower sw:SubGroup managed object table

cfprApSwSubGroupInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.83.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSubGroupDn

1.3.6.1.4.1.9.9.826.2.1.75.83.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SubGroup:dn managed object property

cfprApSwSubGroupRn

1.3.6.1.4.1.9.9.826.2.1.75.83.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SubGroup:rn managed object property

cfprApSwSubGroupAggrPortId

1.3.6.1.4.1.9.9.826.2.1.75.83.1.4

CfprApSwSubGroupAggrPortId (1..48) · Gauge32

Cisco Firepower sw:SubGroup:aggrPortId managed object property

cfprApSwSubGroupLicGP

1.3.6.1.4.1.9.9.826.2.1.75.83.1.5

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:SubGroup:licGP managed object property

cfprApSwSubGroupLicState

1.3.6.1.4.1.9.9.826.2.1.75.83.1.6

CfprApLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower sw:SubGroup:licState managed object property

cfprApSwSubGroupLocale

1.3.6.1.4.1.9.9.826.2.1.75.83.1.7

CfprApNetworkLocale · BITS

Cisco Firepower sw:SubGroup:locale managed object property

cfprApSwSubGroupName

1.3.6.1.4.1.9.9.826.2.1.75.83.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SubGroup:name managed object property

cfprApSwSubGroupSlotId

1.3.6.1.4.1.9.9.826.2.1.75.83.1.9

CfprApSwSubGroupSlotId (1..4) · Gauge32

Cisco Firepower sw:SubGroup:slotId managed object property

cfprApSwSubGroupSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.83.1.10

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:SubGroup:switchId managed object property

cfprApSwSubGroupTransport

1.3.6.1.4.1.9.9.826.2.1.75.83.1.11

CfprApNetworkTransport · BITS

Cisco Firepower sw:SubGroup:transport managed object property

cfprApSwSubGroupType

1.3.6.1.4.1.9.9.826.2.1.75.83.1.12

CfprApNetworkConnectionType · BITS

Cisco Firepower sw:SubGroup:type managed object property

cfprApSwSystemStatsTable

1.3.6.1.4.1.9.9.826.2.1.75.84

Index: cfprApSwSystemStatsInstanceId

Cisco Firepower sw:SystemStats managed object table

cfprApSwSystemStatsInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.84.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSystemStatsDn

1.3.6.1.4.1.9.9.826.2.1.75.84.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SystemStats:dn managed object property

cfprApSwSystemStatsRn

1.3.6.1.4.1.9.9.826.2.1.75.84.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SystemStats:rn managed object property

cfprApSwSystemStatsIntervals

1.3.6.1.4.1.9.9.826.2.1.75.84.1.4

Gauge32

Cisco Firepower sw:SystemStats:intervals managed object property

cfprApSwSystemStatsLoad

1.3.6.1.4.1.9.9.826.2.1.75.84.1.5

INTEGER · Integer32

Cisco Firepower sw:SystemStats:load managed object property

cfprApSwSystemStatsLoadAvg

1.3.6.1.4.1.9.9.826.2.1.75.84.1.6

INTEGER · Integer32

Cisco Firepower sw:SystemStats:loadAvg managed object property

cfprApSwSystemStatsLoadMax

1.3.6.1.4.1.9.9.826.2.1.75.84.1.7

INTEGER · Integer32

Cisco Firepower sw:SystemStats:loadMax managed object property

cfprApSwSystemStatsLoadMin

1.3.6.1.4.1.9.9.826.2.1.75.84.1.8

INTEGER · Integer32

Cisco Firepower sw:SystemStats:loadMin managed object property

cfprApSwSystemStatsMemAvailable

1.3.6.1.4.1.9.9.826.2.1.75.84.1.9

Gauge32

Cisco Firepower sw:SystemStats:memAvailable managed object property

cfprApSwSystemStatsMemAvailableAvg

1.3.6.1.4.1.9.9.826.2.1.75.84.1.10

Gauge32

Cisco Firepower sw:SystemStats:memAvailableAvg managed object property

cfprApSwSystemStatsMemAvailableMax

1.3.6.1.4.1.9.9.826.2.1.75.84.1.11

Gauge32

Cisco Firepower sw:SystemStats:memAvailableMax managed object property

cfprApSwSystemStatsMemAvailableMin

1.3.6.1.4.1.9.9.826.2.1.75.84.1.12

Gauge32

Cisco Firepower sw:SystemStats:memAvailableMin managed object property

cfprApSwSystemStatsMemCached

1.3.6.1.4.1.9.9.826.2.1.75.84.1.13

Gauge32

Cisco Firepower sw:SystemStats:memCached managed object property

cfprApSwSystemStatsMemCachedAvg

1.3.6.1.4.1.9.9.826.2.1.75.84.1.14

Gauge32

Cisco Firepower sw:SystemStats:memCachedAvg managed object property

cfprApSwSystemStatsMemCachedMax

1.3.6.1.4.1.9.9.826.2.1.75.84.1.15

Gauge32

Cisco Firepower sw:SystemStats:memCachedMax managed object property

cfprApSwSystemStatsMemCachedMin

1.3.6.1.4.1.9.9.826.2.1.75.84.1.16

Gauge32

Cisco Firepower sw:SystemStats:memCachedMin managed object property

cfprApSwSystemStatsSuspect

1.3.6.1.4.1.9.9.826.2.1.75.84.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:SystemStats:suspect managed object property

cfprApSwSystemStatsThresholded

1.3.6.1.4.1.9.9.826.2.1.75.84.1.18

CfprApSwSystemStatsThresholded · BITS

Cisco Firepower sw:SystemStats:thresholded managed object property

cfprApSwSystemStatsTimeCollected

1.3.6.1.4.1.9.9.826.2.1.75.84.1.19

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SystemStats:timeCollected managed object property

cfprApSwSystemStatsUpdate

1.3.6.1.4.1.9.9.826.2.1.75.84.1.20

Gauge32

Cisco Firepower sw:SystemStats:update managed object property

cfprApSwSystemStatsHistTable

1.3.6.1.4.1.9.9.826.2.1.75.85

Index: cfprApSwSystemStatsHistInstanceId

Cisco Firepower sw:SystemStatsHist managed object table

cfprApSwSystemStatsHistInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.85.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwSystemStatsHistDn

1.3.6.1.4.1.9.9.826.2.1.75.85.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:SystemStatsHist:dn managed object property

cfprApSwSystemStatsHistRn

1.3.6.1.4.1.9.9.826.2.1.75.85.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:SystemStatsHist:rn managed object property

cfprApSwSystemStatsHistId

1.3.6.1.4.1.9.9.826.2.1.75.85.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:SystemStatsHist:id managed object property

cfprApSwSystemStatsHistLoad

1.3.6.1.4.1.9.9.826.2.1.75.85.1.5

INTEGER · Integer32

Cisco Firepower sw:SystemStatsHist:load managed object property

cfprApSwSystemStatsHistLoadAvg

1.3.6.1.4.1.9.9.826.2.1.75.85.1.6

INTEGER · Integer32

Cisco Firepower sw:SystemStatsHist:loadAvg managed object property

cfprApSwSystemStatsHistLoadMax

1.3.6.1.4.1.9.9.826.2.1.75.85.1.7

INTEGER · Integer32

Cisco Firepower sw:SystemStatsHist:loadMax managed object property

cfprApSwSystemStatsHistLoadMin

1.3.6.1.4.1.9.9.826.2.1.75.85.1.8

INTEGER · Integer32

Cisco Firepower sw:SystemStatsHist:loadMin managed object property

cfprApSwSystemStatsHistMemAvailable

1.3.6.1.4.1.9.9.826.2.1.75.85.1.9

Gauge32

Cisco Firepower sw:SystemStatsHist:memAvailable managed object property

cfprApSwSystemStatsHistMemAvailableAvg

1.3.6.1.4.1.9.9.826.2.1.75.85.1.10

Gauge32

Cisco Firepower sw:SystemStatsHist:memAvailableAvg managed object property

cfprApSwSystemStatsHistMemAvailableMax

1.3.6.1.4.1.9.9.826.2.1.75.85.1.11

Gauge32

Cisco Firepower sw:SystemStatsHist:memAvailableMax managed object property

cfprApSwSystemStatsHistMemAvailableMin

1.3.6.1.4.1.9.9.826.2.1.75.85.1.12

Gauge32

Cisco Firepower sw:SystemStatsHist:memAvailableMin managed object property

cfprApSwSystemStatsHistMemCached

1.3.6.1.4.1.9.9.826.2.1.75.85.1.13

Gauge32

Cisco Firepower sw:SystemStatsHist:memCached managed object property

cfprApSwSystemStatsHistMemCachedAvg

1.3.6.1.4.1.9.9.826.2.1.75.85.1.14

Gauge32

Cisco Firepower sw:SystemStatsHist:memCachedAvg managed object property

cfprApSwSystemStatsHistMemCachedMax

1.3.6.1.4.1.9.9.826.2.1.75.85.1.15

Gauge32

Cisco Firepower sw:SystemStatsHist:memCachedMax managed object property

cfprApSwSystemStatsHistMemCachedMin

1.3.6.1.4.1.9.9.826.2.1.75.85.1.16

Gauge32

Cisco Firepower sw:SystemStatsHist:memCachedMin managed object property

cfprApSwSystemStatsHistMostRecent

1.3.6.1.4.1.9.9.826.2.1.75.85.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:SystemStatsHist:mostRecent managed object property

cfprApSwSystemStatsHistSuspect

1.3.6.1.4.1.9.9.826.2.1.75.85.1.18

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:SystemStatsHist:suspect managed object property

cfprApSwSystemStatsHistThresholded

1.3.6.1.4.1.9.9.826.2.1.75.85.1.19

CfprApSwSystemStatsHistThresholded · BITS

Cisco Firepower sw:SystemStatsHist:thresholded managed object property

cfprApSwSystemStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.2.1.75.85.1.20

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:SystemStatsHist:timeCollected managed object property

cfprApSwUlanTable

1.3.6.1.4.1.9.9.826.2.1.75.86

Index: cfprApSwUlanInstanceId

Cisco Firepower sw:Ulan managed object table

cfprApSwUlanInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.86.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwUlanDn

1.3.6.1.4.1.9.9.826.2.1.75.86.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:Ulan:dn managed object property

cfprApSwUlanRn

1.3.6.1.4.1.9.9.826.2.1.75.86.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Ulan:rn managed object property

cfprApSwUlanAssocPrimaryVlanState

1.3.6.1.4.1.9.9.826.2.1.75.86.1.4

CfprApFabricVlanAssocPrimaryVlanState1 = ok2 = isEmpty3 = doesNotExists4 = isNotPrimaryType5 = isInErrorState · Integer32

Cisco Firepower sw:Ulan:assocPrimaryVlanState managed object property

cfprApSwUlanAssocPrimaryVlanSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.86.1.5

CfprApFabricAVlanAssocPrimaryVlanSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:Ulan:assocPrimaryVlanSwitchId managed object property

cfprApSwUlanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.86.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Ulan:epDn managed object property

cfprApSwUlanId

1.3.6.1.4.1.9.9.826.2.1.75.86.1.7

Gauge32

Cisco Firepower sw:Ulan:id managed object property

cfprApSwUlanIfRole

1.3.6.1.4.1.9.9.826.2.1.75.86.1.8

CfprApFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:Ulan:ifRole managed object property

cfprApSwUlanIfType

1.3.6.1.4.1.9.9.826.2.1.75.86.1.9

CfprApNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:Ulan:ifType managed object property

cfprApSwUlanLocale

1.3.6.1.4.1.9.9.826.2.1.75.86.1.10

CfprApFabricVnetEpLocale · BITS

Cisco Firepower sw:Ulan:locale managed object property

cfprApSwUlanName

1.3.6.1.4.1.9.9.826.2.1.75.86.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Ulan:name managed object property

cfprApSwUlanOperState

1.3.6.1.4.1.9.9.826.2.1.75.86.1.12

CfprApFabricVlanOperState1 = ok2 = errorMisconfigured · Integer32

Cisco Firepower sw:Ulan:operState managed object property

cfprApSwUlanOverlapStateForA

1.3.6.1.4.1.9.9.826.2.1.75.86.1.13

CfprApFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower sw:Ulan:overlapStateForA managed object property

cfprApSwUlanOverlapStateForB

1.3.6.1.4.1.9.9.826.2.1.75.86.1.14

CfprApFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower sw:Ulan:overlapStateForB managed object property

cfprApSwUlanPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.86.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Ulan:peerDn managed object property

cfprApSwUlanPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.75.86.1.16

CfprApFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower sw:Ulan:policyOwner managed object property

cfprApSwUlanPubNwDn

1.3.6.1.4.1.9.9.826.2.1.75.86.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Ulan:pubNwDn managed object property

cfprApSwUlanPubNwId

1.3.6.1.4.1.9.9.826.2.1.75.86.1.18

Gauge32

Cisco Firepower sw:Ulan:pubNwId managed object property

cfprApSwUlanPubNwName

1.3.6.1.4.1.9.9.826.2.1.75.86.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Ulan:pubNwName managed object property

cfprApSwUlanPurpose

1.3.6.1.4.1.9.9.826.2.1.75.86.1.20

CfprApSwUlanPurpose1 = management2 = boot3 = reserved14 = reserved2 · Integer32

Cisco Firepower sw:Ulan:purpose managed object property

cfprApSwUlanSharing

1.3.6.1.4.1.9.9.826.2.1.75.86.1.21

CfprApFabricAVlanSharing0 = none1 = primary2 = isolated3 = community · Integer32

Cisco Firepower sw:Ulan:sharing managed object property

cfprApSwUlanSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.86.1.22

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:Ulan:switchId managed object property

cfprApSwUlanTransport

1.3.6.1.4.1.9.9.826.2.1.75.86.1.23

CfprApFabricAVlanTransport · BITS

Cisco Firepower sw:Ulan:transport managed object property

cfprApSwUlanType

1.3.6.1.4.1.9.9.826.2.1.75.86.1.24

CfprApFabricAVlanType · BITS

Cisco Firepower sw:Ulan:type managed object property

cfprApSwUlanVlanType

1.3.6.1.4.1.9.9.826.2.1.75.86.1.25

CfprApFabricEpVlanVlanType0 = regular1 = default2 = native3 = fcoeuplinknative · Integer32

Cisco Firepower sw:Ulan:vlanType managed object property

cfprApSwUtilityDomainTable

1.3.6.1.4.1.9.9.826.2.1.75.87

Index: cfprApSwUtilityDomainInstanceId

Cisco Firepower sw:UtilityDomain managed object table

cfprApSwUtilityDomainInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.87.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwUtilityDomainDn

1.3.6.1.4.1.9.9.826.2.1.75.87.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:UtilityDomain:dn managed object property

cfprApSwUtilityDomainRn

1.3.6.1.4.1.9.9.826.2.1.75.87.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:rn managed object property

cfprApSwUtilityDomainFsmDescr

1.3.6.1.4.1.9.9.826.2.1.75.87.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:fsmDescr managed object property

cfprApSwUtilityDomainFsmPrev

1.3.6.1.4.1.9.9.826.2.1.75.87.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:fsmPrev managed object property

cfprApSwUtilityDomainFsmProgr

1.3.6.1.4.1.9.9.826.2.1.75.87.1.6

Gauge32

Cisco Firepower sw:UtilityDomain:fsmProgr managed object property

cfprApSwUtilityDomainFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.2.1.75.87.1.7

Gauge32

Cisco Firepower sw:UtilityDomain:fsmRmtInvErrCode managed object property

cfprApSwUtilityDomainFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.87.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:fsmRmtInvErrDescr managed object property

cfprApSwUtilityDomainFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.2.1.75.87.1.9

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:UtilityDomain:fsmRmtInvRslt managed object property

cfprApSwUtilityDomainFsmStageDescr

1.3.6.1.4.1.9.9.826.2.1.75.87.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:fsmStageDescr managed object property

cfprApSwUtilityDomainFsmStamp

1.3.6.1.4.1.9.9.826.2.1.75.87.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:UtilityDomain:fsmStamp managed object property

cfprApSwUtilityDomainFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.87.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:fsmStatus managed object property

cfprApSwUtilityDomainFsmTry

1.3.6.1.4.1.9.9.826.2.1.75.87.1.13

Gauge32

Cisco Firepower sw:UtilityDomain:fsmTry managed object property

cfprApSwUtilityDomainLocale

1.3.6.1.4.1.9.9.826.2.1.75.87.1.14

CfprApSwUtilityDomainLocale · BITS

Cisco Firepower sw:UtilityDomain:locale managed object property

cfprApSwUtilityDomainName

1.3.6.1.4.1.9.9.826.2.1.75.87.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomain:name managed object property

cfprApSwUtilityDomainSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.87.1.16

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:UtilityDomain:switchId managed object property

cfprApSwUtilityDomainTransport

1.3.6.1.4.1.9.9.826.2.1.75.87.1.17

CfprApNetworkTransport · BITS

Cisco Firepower sw:UtilityDomain:transport managed object property

cfprApSwUtilityDomainType

1.3.6.1.4.1.9.9.826.2.1.75.87.1.18

CfprApSwUtilityDomainType · BITS

Cisco Firepower sw:UtilityDomain:type managed object property

cfprApSwUtilityDomainFsmTable

1.3.6.1.4.1.9.9.826.2.1.75.88

Index: cfprApSwUtilityDomainFsmInstanceId

Cisco Firepower sw:UtilityDomainFsm managed object table

cfprApSwUtilityDomainFsmInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.88.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwUtilityDomainFsmDn

1.3.6.1.4.1.9.9.826.2.1.75.88.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:UtilityDomainFsm:dn managed object property

cfprApSwUtilityDomainFsmRn

1.3.6.1.4.1.9.9.826.2.1.75.88.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomainFsm:rn managed object property

cfprApSwUtilityDomainFsmCompletionTime

1.3.6.1.4.1.9.9.826.2.1.75.88.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:UtilityDomainFsm:completionTime managed object property

cfprApSwUtilityDomainFsmCurrentFsm

1.3.6.1.4.1.9.9.826.2.1.75.88.1.5

CfprApSwUtilityDomainFsmCurrentFsm0 = nop102 = deploy · Integer32

Cisco Firepower sw:UtilityDomainFsm:currentFsm managed object property

cfprApSwUtilityDomainFsmDescrData

1.3.6.1.4.1.9.9.826.2.1.75.88.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomainFsm:descr managed object property

cfprApSwUtilityDomainFsmFsmStatus

1.3.6.1.4.1.9.9.826.2.1.75.88.1.7

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:UtilityDomainFsm:fsmStatus managed object property

cfprApSwUtilityDomainFsmProgress

1.3.6.1.4.1.9.9.826.2.1.75.88.1.8

Gauge32

Cisco Firepower sw:UtilityDomainFsm:progress managed object property

cfprApSwUtilityDomainFsmRmtErrCode

1.3.6.1.4.1.9.9.826.2.1.75.88.1.9

Gauge32

Cisco Firepower sw:UtilityDomainFsm:rmtErrCode managed object property

cfprApSwUtilityDomainFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.2.1.75.88.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomainFsm:rmtErrDescr managed object property

cfprApSwUtilityDomainFsmRmtRslt

1.3.6.1.4.1.9.9.826.2.1.75.88.1.11

CfprApConditionRemoteInvRslt · BITS

Cisco Firepower sw:UtilityDomainFsm:rmtRslt managed object property

cfprApSwUtilityDomainFsmStageTable

1.3.6.1.4.1.9.9.826.2.1.75.89

Index: cfprApSwUtilityDomainFsmStageInstanceId

Cisco Firepower sw:UtilityDomainFsmStage managed object table

cfprApSwUtilityDomainFsmStageInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.89.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwUtilityDomainFsmStageDn

1.3.6.1.4.1.9.9.826.2.1.75.89.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:UtilityDomainFsmStage:dn managed object property

cfprApSwUtilityDomainFsmStageRn

1.3.6.1.4.1.9.9.826.2.1.75.89.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomainFsmStage:rn managed object property

cfprApSwUtilityDomainFsmStageDescrData

1.3.6.1.4.1.9.9.826.2.1.75.89.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomainFsmStage:descr managed object property

cfprApSwUtilityDomainFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.2.1.75.89.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower sw:UtilityDomainFsmStage:lastUpdateTime managed object property

cfprApSwUtilityDomainFsmStageName

1.3.6.1.4.1.9.9.826.2.1.75.89.1.6

CfprApSwUtilityDomainFsmStageName0 = nop102 = deployBegin103 = deployUpdateConnectivity804 = deployFail805 = deploySuccess · Integer32

Cisco Firepower sw:UtilityDomainFsmStage:name managed object property

cfprApSwUtilityDomainFsmStageOrder

1.3.6.1.4.1.9.9.826.2.1.75.89.1.7

Gauge32

Cisco Firepower sw:UtilityDomainFsmStage:order managed object property

cfprApSwUtilityDomainFsmStageRetry

1.3.6.1.4.1.9.9.826.2.1.75.89.1.8

Gauge32

Cisco Firepower sw:UtilityDomainFsmStage:retry managed object property

cfprApSwUtilityDomainFsmStageStageStatus

1.3.6.1.4.1.9.9.826.2.1.75.89.1.9

CfprApFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower sw:UtilityDomainFsmStage:stageStatus managed object property

cfprApSwUtilityDomainFsmTaskTable

1.3.6.1.4.1.9.9.826.2.1.75.90

Index: cfprApSwUtilityDomainFsmTaskInstanceId

Cisco Firepower sw:UtilityDomainFsmTask managed object table

cfprApSwUtilityDomainFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.90.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwUtilityDomainFsmTaskDn

1.3.6.1.4.1.9.9.826.2.1.75.90.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:UtilityDomainFsmTask:dn managed object property

cfprApSwUtilityDomainFsmTaskRn

1.3.6.1.4.1.9.9.826.2.1.75.90.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:UtilityDomainFsmTask:rn managed object property

cfprApSwUtilityDomainFsmTaskCompletion

1.3.6.1.4.1.9.9.826.2.1.75.90.1.4

CfprApFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower sw:UtilityDomainFsmTask:completion managed object property

cfprApSwUtilityDomainFsmTaskFlags

1.3.6.1.4.1.9.9.826.2.1.75.90.1.5

CfprApFsmFlags · BITS

Cisco Firepower sw:UtilityDomainFsmTask:flags managed object property

cfprApSwUtilityDomainFsmTaskItem

1.3.6.1.4.1.9.9.826.2.1.75.90.1.6

CfprApSwUtilityDomainFsmTaskItem0 = nop102 = deploy · Integer32

Cisco Firepower sw:UtilityDomainFsmTask:item managed object property

cfprApSwUtilityDomainFsmTaskSeqId

1.3.6.1.4.1.9.9.826.2.1.75.90.1.7

Gauge32

Cisco Firepower sw:UtilityDomainFsmTask:seqId managed object property

cfprApSwVlanTable

1.3.6.1.4.1.9.9.826.2.1.75.92

Index: cfprApSwVlanInstanceId

Cisco Firepower sw:Vlan managed object table

cfprApSwVlanInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.92.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwVlanDn

1.3.6.1.4.1.9.9.826.2.1.75.92.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:Vlan:dn managed object property

cfprApSwVlanRn

1.3.6.1.4.1.9.9.826.2.1.75.92.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vlan:rn managed object property

cfprApSwVlanAssocPrimaryVlanState

1.3.6.1.4.1.9.9.826.2.1.75.92.1.4

CfprApFabricVlanAssocPrimaryVlanState1 = ok2 = isEmpty3 = doesNotExists4 = isNotPrimaryType5 = isInErrorState · Integer32

Cisco Firepower sw:Vlan:assocPrimaryVlanState managed object property

cfprApSwVlanAssocPrimaryVlanSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.92.1.5

CfprApFabricAVlanAssocPrimaryVlanSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:Vlan:assocPrimaryVlanSwitchId managed object property

cfprApSwVlanCompressionType

1.3.6.1.4.1.9.9.826.2.1.75.92.1.6

CfprApSwVlanCompType1 = included2 = excluded · Integer32

Cisco Firepower sw:Vlan:compressionType managed object property

cfprApSwVlanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.92.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vlan:epDn managed object property

cfprApSwVlanId

1.3.6.1.4.1.9.9.826.2.1.75.92.1.8

Gauge32

Cisco Firepower sw:Vlan:id managed object property

cfprApSwVlanIfRole

1.3.6.1.4.1.9.9.826.2.1.75.92.1.9

CfprApFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:Vlan:ifRole managed object property

cfprApSwVlanIfType

1.3.6.1.4.1.9.9.826.2.1.75.92.1.10

CfprApNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:Vlan:ifType managed object property

cfprApSwVlanLc

1.3.6.1.4.1.9.9.826.2.1.75.92.1.11

CfprApSwVlanLc0 = available1 = allocated2 = deallocated3 = repurposed4 = pending5 = provisioned · Integer32

Cisco Firepower sw:Vlan:lc managed object property

cfprApSwVlanLocale

1.3.6.1.4.1.9.9.826.2.1.75.92.1.12

CfprApFabricVnetEpLocale · BITS

Cisco Firepower sw:Vlan:locale managed object property

cfprApSwVlanMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.92.1.13

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:Vlan:monTrafDir managed object property

cfprApSwVlanName

1.3.6.1.4.1.9.9.826.2.1.75.92.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vlan:name managed object property

cfprApSwVlanOperState

1.3.6.1.4.1.9.9.826.2.1.75.92.1.15

CfprApFabricVlanOperState1 = ok2 = errorMisconfigured · Integer32

Cisco Firepower sw:Vlan:operState managed object property

cfprApSwVlanOverlapStateForA

1.3.6.1.4.1.9.9.826.2.1.75.92.1.16

CfprApFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower sw:Vlan:overlapStateForA managed object property

cfprApSwVlanOverlapStateForB

1.3.6.1.4.1.9.9.826.2.1.75.92.1.17

CfprApFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower sw:Vlan:overlapStateForB managed object property

cfprApSwVlanPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.92.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vlan:peerDn managed object property

cfprApSwVlanPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.75.92.1.19

CfprApFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower sw:Vlan:policyOwner managed object property

cfprApSwVlanPubNwDn

1.3.6.1.4.1.9.9.826.2.1.75.92.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vlan:pubNwDn managed object property

cfprApSwVlanPubNwId

1.3.6.1.4.1.9.9.826.2.1.75.92.1.21

Gauge32

Cisco Firepower sw:Vlan:pubNwId managed object property

cfprApSwVlanPubNwName

1.3.6.1.4.1.9.9.826.2.1.75.92.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vlan:pubNwName managed object property

cfprApSwVlanQuerierIpAddrs

1.3.6.1.4.1.9.9.826.2.1.75.92.1.23

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower sw:Vlan:querierIpAddrs managed object property

cfprApSwVlanSecVlanPerPrimaryVlanCount

1.3.6.1.4.1.9.9.826.2.1.75.92.1.24

Gauge32

Cisco Firepower sw:Vlan:secVlanPerPrimaryVlanCount managed object property

cfprApSwVlanSecVlanPerPrimaryVlanCountStatus

1.3.6.1.4.1.9.9.826.2.1.75.92.1.25

CfprApNetworkVlanCountStatus0 = withinLimit1 = aboveLimit · Integer32

Cisco Firepower sw:Vlan:secVlanPerPrimaryVlanCountStatus managed object property

cfprApSwVlanSharing

1.3.6.1.4.1.9.9.826.2.1.75.92.1.26

CfprApFabricAVlanSharing0 = none1 = primary2 = isolated3 = community · Integer32

Cisco Firepower sw:Vlan:sharing managed object property

cfprApSwVlanSnoopingEnabled

1.3.6.1.4.1.9.9.826.2.1.75.92.1.27

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower sw:Vlan:snoopingEnabled managed object property

cfprApSwVlanSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.92.1.28

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:Vlan:switchId managed object property

cfprApSwVlanTransport

1.3.6.1.4.1.9.9.826.2.1.75.92.1.29

CfprApFabricAVlanTransport · BITS

Cisco Firepower sw:Vlan:transport managed object property

cfprApSwVlanType

1.3.6.1.4.1.9.9.826.2.1.75.92.1.30

CfprApFabricAVlanType · BITS

Cisco Firepower sw:Vlan:type managed object property

cfprApSwVlanVlanType

1.3.6.1.4.1.9.9.826.2.1.75.92.1.31

CfprApFabricEpVlanVlanType0 = regular1 = default2 = native3 = fcoeuplinknative · Integer32

Cisco Firepower sw:Vlan:vlanType managed object property

cfprApSwVlanGroupTable

1.3.6.1.4.1.9.9.826.2.1.75.93

Index: cfprApSwVlanGroupInstanceId

Cisco Firepower sw:VlanGroup managed object table

cfprApSwVlanGroupInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.93.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwVlanGroupDn

1.3.6.1.4.1.9.9.826.2.1.75.93.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:VlanGroup:dn managed object property

cfprApSwVlanGroupRn

1.3.6.1.4.1.9.9.826.2.1.75.93.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:VlanGroup:rn managed object property

cfprApSwVlanGroupId

1.3.6.1.4.1.9.9.826.2.1.75.93.1.4

Gauge32

Cisco Firepower sw:VlanGroup:id managed object property

cfprApSwVlanGroupPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.93.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:VlanGroup:peerDn managed object property

cfprApSwVlanGroupSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.93.1.6

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:VlanGroup:switchId managed object property

cfprApSwVlanGroupType

1.3.6.1.4.1.9.9.826.2.1.75.93.1.7

CfprApSwVlanGroupType1 = compressed2 = uncompressed · Integer32

Cisco Firepower sw:VlanGroup:type managed object property

cfprApSwVlanPortNsTable

1.3.6.1.4.1.9.9.826.2.1.75.94

Index: cfprApSwVlanPortNsInstanceId

Cisco Firepower sw:VlanPortNs managed object table

cfprApSwVlanPortNsInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.94.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwVlanPortNsDn

1.3.6.1.4.1.9.9.826.2.1.75.94.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:VlanPortNs:dn managed object property

cfprApSwVlanPortNsRn

1.3.6.1.4.1.9.9.826.2.1.75.94.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:VlanPortNs:rn managed object property

cfprApSwVlanPortNsAccessVlanPortCount

1.3.6.1.4.1.9.9.826.2.1.75.94.1.4

Gauge32

Cisco Firepower sw:VlanPortNs:accessVlanPortCount managed object property

cfprApSwVlanPortNsAllocStatus

1.3.6.1.4.1.9.9.826.2.1.75.94.1.5

CfprApSwVlanPortNsAllocStatus0 = available1 = exceeded · Integer32

Cisco Firepower sw:VlanPortNs:allocStatus managed object property

cfprApSwVlanPortNsBorderVlanPortCount

1.3.6.1.4.1.9.9.826.2.1.75.94.1.6

Gauge32

Cisco Firepower sw:VlanPortNs:borderVlanPortCount managed object property

cfprApSwVlanPortNsConfigStatus

1.3.6.1.4.1.9.9.826.2.1.75.94.1.7

CfprApSwConfigStatus1 = none2 = noVlanComp · Integer32

Cisco Firepower sw:VlanPortNs:configStatus managed object property

cfprApSwVlanPortNsLimit

1.3.6.1.4.1.9.9.826.2.1.75.94.1.8

Gauge32

Cisco Firepower sw:VlanPortNs:limit managed object property

cfprApSwVlanPortNsSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.94.1.9

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:VlanPortNs:switchId managed object property

cfprApSwVlanPortNsTotalVlanPortCount

1.3.6.1.4.1.9.9.826.2.1.75.94.1.10

Gauge32

Cisco Firepower sw:VlanPortNs:totalVlanPortCount managed object property

cfprApSwVlanPortNsVlanCompOffLimit

1.3.6.1.4.1.9.9.826.2.1.75.94.1.11

Gauge32

Cisco Firepower sw:VlanPortNs:vlanCompOffLimit managed object property

cfprApSwVlanPortNsVlanCompOnLimit

1.3.6.1.4.1.9.9.826.2.1.75.94.1.12

Gauge32

Cisco Firepower sw:VlanPortNs:vlanCompOnLimit managed object property

cfprApSwVlanPortNsOverrideTable

1.3.6.1.4.1.9.9.826.2.1.75.95

Index: cfprApSwVlanPortNsOverrideInstanceId

Cisco Firepower sw:VlanPortNsOverride managed object table

cfprApSwVlanPortNsOverrideInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.95.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwVlanPortNsOverrideDn

1.3.6.1.4.1.9.9.826.2.1.75.95.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:VlanPortNsOverride:dn managed object property

cfprApSwVlanPortNsOverrideRn

1.3.6.1.4.1.9.9.826.2.1.75.95.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:VlanPortNsOverride:rn managed object property

cfprApSwVlanPortNsOverrideLimit

1.3.6.1.4.1.9.9.826.2.1.75.95.1.4

Gauge32

Cisco Firepower sw:VlanPortNsOverride:limit managed object property

cfprApSwVlanRefTable

1.3.6.1.4.1.9.9.826.2.1.75.96

Index: cfprApSwVlanRefInstanceId

Cisco Firepower sw:VlanRef managed object table

cfprApSwVlanRefInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.96.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwVlanRefDn

1.3.6.1.4.1.9.9.826.2.1.75.96.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:VlanRef:dn managed object property

cfprApSwVlanRefRn

1.3.6.1.4.1.9.9.826.2.1.75.96.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:VlanRef:rn managed object property

cfprApSwVlanRefCompressionType

1.3.6.1.4.1.9.9.826.2.1.75.96.1.4

CfprApSwVlanCompType1 = included2 = excluded · Integer32

Cisco Firepower sw:VlanRef:compressionType managed object property

cfprApSwVlanRefConfigStatus

1.3.6.1.4.1.9.9.826.2.1.75.96.1.5

CfprApSwVlanConfigStatusType1 = applied2 = unApplied · Integer32

Cisco Firepower sw:VlanRef:configStatus managed object property

cfprApSwVlanRefId

1.3.6.1.4.1.9.9.826.2.1.75.96.1.6

Gauge32

Cisco Firepower sw:VlanRef:id managed object property

cfprApSwVlanRefPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.96.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:VlanRef:peerDn managed object property

cfprApSwVsanTable

1.3.6.1.4.1.9.9.826.2.1.75.97

Index: cfprApSwVsanInstanceId

Cisco Firepower sw:Vsan managed object table

cfprApSwVsanInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.97.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwVsanDn

1.3.6.1.4.1.9.9.826.2.1.75.97.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:Vsan:dn managed object property

cfprApSwVsanRn

1.3.6.1.4.1.9.9.826.2.1.75.97.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vsan:rn managed object property

cfprApSwVsanDefaultZoning

1.3.6.1.4.1.9.9.826.2.1.75.97.1.4

CfprApFabricDefaultZoningState0 = disabled1 = enabled · Integer32

Cisco Firepower sw:Vsan:defaultZoning managed object property

cfprApSwVsanEpDn

1.3.6.1.4.1.9.9.826.2.1.75.97.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vsan:epDn managed object property

cfprApSwVsanFcZoneSharingMode

1.3.6.1.4.1.9.9.826.2.1.75.97.1.6

CfprApFabricFcZoneSharingMode0 = coalesce1 = clearUnmanagedZoneAll · Integer32

Cisco Firepower sw:Vsan:fcZoneSharingMode managed object property

cfprApSwVsanFcoeVlan

1.3.6.1.4.1.9.9.826.2.1.75.97.1.7

Gauge32

Cisco Firepower sw:Vsan:fcoeVlan managed object property

cfprApSwVsanFltAggr

1.3.6.1.4.1.9.9.826.2.1.75.97.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:Vsan:fltAggr managed object property

cfprApSwVsanId

1.3.6.1.4.1.9.9.826.2.1.75.97.1.9

Gauge32

Cisco Firepower sw:Vsan:id managed object property

cfprApSwVsanIfRole

1.3.6.1.4.1.9.9.826.2.1.75.97.1.10

CfprApFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower sw:Vsan:ifRole managed object property

cfprApSwVsanIfType

1.3.6.1.4.1.9.9.826.2.1.75.97.1.11

CfprApNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual4 = fabric · Integer32

Cisco Firepower sw:Vsan:ifType managed object property

cfprApSwVsanLc

1.3.6.1.4.1.9.9.826.2.1.75.97.1.12

CfprApFsmLifecycle0 = available1 = allocated2 = deallocated3 = repurposed · Integer32

Cisco Firepower sw:Vsan:lc managed object property

cfprApSwVsanLocale

1.3.6.1.4.1.9.9.826.2.1.75.97.1.13

CfprApFabricVnetEpLocale · BITS

Cisco Firepower sw:Vsan:locale managed object property

cfprApSwVsanMonTrafDir

1.3.6.1.4.1.9.9.826.2.1.75.97.1.14

CfprApFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower sw:Vsan:monTrafDir managed object property

cfprApSwVsanName

1.3.6.1.4.1.9.9.826.2.1.75.97.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vsan:name managed object property

cfprApSwVsanOperState

1.3.6.1.4.1.9.9.826.2.1.75.97.1.16

CfprApFabricVsanOperState1 = ok2 = errorMisconfigured3 = errorReserved · Integer32

Cisco Firepower sw:Vsan:operState managed object property

cfprApSwVsanPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.97.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:Vsan:peerDn managed object property

cfprApSwVsanPolicyOwner

1.3.6.1.4.1.9.9.826.2.1.75.97.1.18

CfprApFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower sw:Vsan:policyOwner managed object property

cfprApSwVsanSwitchId

1.3.6.1.4.1.9.9.826.2.1.75.97.1.19

CfprApNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower sw:Vsan:switchId managed object property

cfprApSwVsanTransport

1.3.6.1.4.1.9.9.826.2.1.75.97.1.20

CfprApFabricAVsanTransport · BITS

Cisco Firepower sw:Vsan:transport managed object property

cfprApSwVsanType

1.3.6.1.4.1.9.9.826.2.1.75.97.1.21

CfprApFabricAVsanType · BITS

Cisco Firepower sw:Vsan:type managed object property

cfprApSwVsanZoningState

1.3.6.1.4.1.9.9.826.2.1.75.97.1.22

CfprApFabricZoningState0 = disabled1 = enabled · Integer32

Cisco Firepower sw:Vsan:zoningState managed object property

cfprApSwZoneInitiatorMemberTable

1.3.6.1.4.1.9.9.826.2.1.75.98

Index: cfprApSwZoneInitiatorMemberInstanceId

Cisco Firepower sw:ZoneInitiatorMember managed object table

cfprApSwZoneInitiatorMemberInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.98.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwZoneInitiatorMemberDn

1.3.6.1.4.1.9.9.826.2.1.75.98.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:ZoneInitiatorMember:dn managed object property

cfprApSwZoneInitiatorMemberRn

1.3.6.1.4.1.9.9.826.2.1.75.98.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneInitiatorMember:rn managed object property

cfprApSwZoneInitiatorMemberEpDn

1.3.6.1.4.1.9.9.826.2.1.75.98.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneInitiatorMember:epDn managed object property

cfprApSwZoneInitiatorMemberLc

1.3.6.1.4.1.9.9.826.2.1.75.98.1.5

CfprApSwFcZoneMemberLc0 = available1 = allocated2 = deallocated3 = repurposed · Integer32

Cisco Firepower sw:ZoneInitiatorMember:lc managed object property

cfprApSwZoneInitiatorMemberName

1.3.6.1.4.1.9.9.826.2.1.75.98.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneInitiatorMember:name managed object property

cfprApSwZoneInitiatorMemberPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.98.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneInitiatorMember:peerDn managed object property

cfprApSwZoneInitiatorMemberWwpn

1.3.6.1.4.1.9.9.826.2.1.75.98.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:ZoneInitiatorMember:wwpn managed object property

cfprApSwZoneTargetMemberTable

1.3.6.1.4.1.9.9.826.2.1.75.99

Index: cfprApSwZoneTargetMemberInstanceId

Cisco Firepower sw:ZoneTargetMember managed object table

cfprApSwZoneTargetMemberInstanceId

1.3.6.1.4.1.9.9.826.2.1.75.99.1.1

CfprApManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprApManagedObjectId, which is an integer uniquely identifying an object. The CfprApManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprApManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprApSwZoneTargetMemberDn

1.3.6.1.4.1.9.9.826.2.1.75.99.1.2

CfprApManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower sw:ZoneTargetMember:dn managed object property

cfprApSwZoneTargetMemberRn

1.3.6.1.4.1.9.9.826.2.1.75.99.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneTargetMember:rn managed object property

cfprApSwZoneTargetMemberEpDn

1.3.6.1.4.1.9.9.826.2.1.75.99.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneTargetMember:epDn managed object property

cfprApSwZoneTargetMemberLc

1.3.6.1.4.1.9.9.826.2.1.75.99.1.5

CfprApSwFcZoneMemberLc0 = available1 = allocated2 = deallocated3 = repurposed · Integer32

Cisco Firepower sw:ZoneTargetMember:lc managed object property

cfprApSwZoneTargetMemberName

1.3.6.1.4.1.9.9.826.2.1.75.99.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneTargetMember:name managed object property

cfprApSwZoneTargetMemberPeerDn

1.3.6.1.4.1.9.9.826.2.1.75.99.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower sw:ZoneTargetMember:peerDn managed object property

cfprApSwZoneTargetMemberWwpn

1.3.6.1.4.1.9.9.826.2.1.75.99.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower sw:ZoneTargetMember:wwpn managed object property

↑ To TOC