EZ5 MIB Catalog

CISCO-FIREPOWER-COMPUTE-MIB

2024-05-16

MIB representation of the Cisco Firepower COMPUTE management information model package

Download CISCO-FIREPOWER-COMPUTE-MIB.txt Open CISCO-FIREPOWER-COMPUTE-MIB.txt in a new tab

TABLES (65)

Tables (65)

NameOID
cfprComputeAutoconfigPolicyTable1.3.6.1.4.1.9.9.826.1.12.1
cfprComputeBladeTable1.3.6.1.4.1.9.9.826.1.12.2
cfprComputeBladeDiscPolicyTable1.3.6.1.4.1.9.9.826.1.12.3
cfprComputeBladeFsmTable1.3.6.1.4.1.9.9.826.1.12.4
cfprComputeBladeFsmStageTable1.3.6.1.4.1.9.9.826.1.12.5
cfprComputeBladeFsmTaskTable1.3.6.1.4.1.9.9.826.1.12.6
cfprComputeBladeInheritPolicyTable1.3.6.1.4.1.9.9.826.1.12.7
cfprComputeBoardTable1.3.6.1.4.1.9.9.826.1.12.8
cfprComputeBoardConnectorTable1.3.6.1.4.1.9.9.826.1.12.9
cfprComputeBoardControllerTable1.3.6.1.4.1.9.9.826.1.12.10
cfprComputeChassisConnPolicyTable1.3.6.1.4.1.9.9.826.1.12.11
cfprComputeChassisDiscPolicyTable1.3.6.1.4.1.9.9.826.1.12.12
cfprComputeChassisQualTable1.3.6.1.4.1.9.9.826.1.12.13
cfprComputeDefaultsTable1.3.6.1.4.1.9.9.826.1.12.14
cfprComputeExtBoardTable1.3.6.1.4.1.9.9.826.1.12.15
cfprComputeFwSyncAckTable1.3.6.1.4.1.9.9.826.1.12.16
cfprComputeHealthLedSensorAlarmTable1.3.6.1.4.1.9.9.826.1.12.17
cfprComputeIOHubTable1.3.6.1.4.1.9.9.826.1.12.18
cfprComputeIOHubEnvStatsTable1.3.6.1.4.1.9.9.826.1.12.19
cfprComputeIOHubEnvStatsHistTable1.3.6.1.4.1.9.9.826.1.12.20
cfprComputeKvmMgmtPolicyTable1.3.6.1.4.1.9.9.826.1.12.21
cfprComputeMbPowerStatsTable1.3.6.1.4.1.9.9.826.1.12.22
cfprComputeMbPowerStatsHistTable1.3.6.1.4.1.9.9.826.1.12.23
cfprComputeMbTempStatsTable1.3.6.1.4.1.9.9.826.1.12.24
cfprComputeMbTempStatsHistTable1.3.6.1.4.1.9.9.826.1.12.25
cfprComputeMemoryConfigPolicyTable1.3.6.1.4.1.9.9.826.1.12.26
cfprComputeMemoryConfigurationTable1.3.6.1.4.1.9.9.826.1.12.27
cfprComputeMemoryUnitConstraintDefTable1.3.6.1.4.1.9.9.826.1.12.28
cfprComputePCIeFatalCompletionStatsTable1.3.6.1.4.1.9.9.826.1.12.29
cfprComputePCIeFatalProtocolStatsTable1.3.6.1.4.1.9.9.826.1.12.30
cfprComputePCIeFatalReceiveStatsTable1.3.6.1.4.1.9.9.826.1.12.31
cfprComputePCIeFatalStatsTable1.3.6.1.4.1.9.9.826.1.12.32
cfprComputePciCapTable1.3.6.1.4.1.9.9.826.1.12.33
cfprComputePciSlotScanDefTable1.3.6.1.4.1.9.9.826.1.12.34
cfprComputePhysicalAssocCtxTable1.3.6.1.4.1.9.9.826.1.12.35
cfprComputePhysicalFsmTable1.3.6.1.4.1.9.9.826.1.12.36
cfprComputePhysicalFsmStageTable1.3.6.1.4.1.9.9.826.1.12.37
cfprComputePhysicalFsmTaskTable1.3.6.1.4.1.9.9.826.1.12.38
cfprComputePhysicalQualTable1.3.6.1.4.1.9.9.826.1.12.39
cfprComputePlatformTable1.3.6.1.4.1.9.9.826.1.12.40
cfprComputePnuOSImageTable1.3.6.1.4.1.9.9.826.1.12.41
cfprComputePoolTable1.3.6.1.4.1.9.9.826.1.12.42
cfprComputePoolPolicyRefTable1.3.6.1.4.1.9.9.826.1.12.43
cfprComputePoolableTable1.3.6.1.4.1.9.9.826.1.12.44
cfprComputePooledRackUnitTable1.3.6.1.4.1.9.9.826.1.12.45
cfprComputePooledSlotTable1.3.6.1.4.1.9.9.826.1.12.46
cfprComputePoolingPolicyTable1.3.6.1.4.1.9.9.826.1.12.47
cfprComputePsuControlTable1.3.6.1.4.1.9.9.826.1.12.48
cfprComputePsuPolicyTable1.3.6.1.4.1.9.9.826.1.12.49
cfprComputeQualTable1.3.6.1.4.1.9.9.826.1.12.50
cfprComputeRackQualTable1.3.6.1.4.1.9.9.826.1.12.51
cfprComputeRackUnitTable1.3.6.1.4.1.9.9.826.1.12.52
cfprComputeRackUnitFsmTable1.3.6.1.4.1.9.9.826.1.12.53
cfprComputeRackUnitFsmStageTable1.3.6.1.4.1.9.9.826.1.12.54
cfprComputeRackUnitFsmTaskTable1.3.6.1.4.1.9.9.826.1.12.55
cfprComputeRackUnitMbTempStatsTable1.3.6.1.4.1.9.9.826.1.12.56
cfprComputeRackUnitMbTempStatsHistTable1.3.6.1.4.1.9.9.826.1.12.57
cfprComputeRtcBatteryTable1.3.6.1.4.1.9.9.826.1.12.58
cfprComputeScrubPolicyTable1.3.6.1.4.1.9.9.826.1.12.59
cfprComputeServerDiscPolicyTable1.3.6.1.4.1.9.9.826.1.12.60
cfprComputeServerDiscPolicyFsmTable1.3.6.1.4.1.9.9.826.1.12.61
cfprComputeServerDiscPolicyFsmStageTable1.3.6.1.4.1.9.9.826.1.12.62
cfprComputeServerDiscPolicyFsmTaskTable1.3.6.1.4.1.9.9.826.1.12.63
cfprComputeServerMgmtPolicyTable1.3.6.1.4.1.9.9.826.1.12.64
cfprComputeSlotQualTable1.3.6.1.4.1.9.9.826.1.12.65

END OF TOC

Table details

cfprComputeAutoconfigPolicyTable

1.3.6.1.4.1.9.9.826.1.12.1

Index: cfprComputeAutoconfigPolicyInstanceId

Cisco Firepower compute:AutoconfigPolicy managed object table

cfprComputeAutoconfigPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.1.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeAutoconfigPolicyDn

1.3.6.1.4.1.9.9.826.1.12.1.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:AutoconfigPolicy:dn managed object property

cfprComputeAutoconfigPolicyRn

1.3.6.1.4.1.9.9.826.1.12.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:rn managed object property

cfprComputeAutoconfigPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.1.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:descr managed object property

cfprComputeAutoconfigPolicyDstDn

1.3.6.1.4.1.9.9.826.1.12.1.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:dstDn managed object property

cfprComputeAutoconfigPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.1.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:intId managed object property

cfprComputeAutoconfigPolicyName

1.3.6.1.4.1.9.9.826.1.12.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:name managed object property

cfprComputeAutoconfigPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.1.1.8

Gauge32

Cisco Firepower compute:AutoconfigPolicy:policyLevel managed object property

cfprComputeAutoconfigPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.1.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:AutoconfigPolicy:policyOwner managed object property

cfprComputeAutoconfigPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.1.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:qualifier managed object property

cfprComputeAutoconfigPolicySrcTemplName

1.3.6.1.4.1.9.9.826.1.12.1.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:AutoconfigPolicy:srcTemplName managed object property

cfprComputeBladeTable

1.3.6.1.4.1.9.9.826.1.12.2

Index: cfprComputeBladeInstanceId

Cisco Firepower compute:Blade managed object table

cfprComputeBladeInstanceId

1.3.6.1.4.1.9.9.826.1.12.2.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBladeDn

1.3.6.1.4.1.9.9.826.1.12.2.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Blade:dn managed object property

cfprComputeBladeRn

1.3.6.1.4.1.9.9.826.1.12.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:rn managed object property

cfprComputeBladeAdminPower

1.3.6.1.4.1.9.9.826.1.12.2.1.4

CfprComputeAdminPowerState2 = cycleImmediate3 = cycleWait4 = hardResetImmediate5 = hardResetWait12 = cmosResetImmediate13 = bmcResetImmediate14 = bmcResetWait15 = diagnosticInterrupt16 = kvmReset30 = policy31 = adminUp32 = adminDown33 = ipmiReset · Integer32

Cisco Firepower compute:Blade:adminPower managed object property

cfprComputeBladeAdminState

1.3.6.1.4.1.9.9.826.1.12.2.1.5

CfprComputeAdminState1 = inService2 = outOfService · Integer32

Cisco Firepower compute:Blade:adminState managed object property

cfprComputeBladeAssignedToDn

1.3.6.1.4.1.9.9.826.1.12.2.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:assignedToDn managed object property

cfprComputeBladeAssociation

1.3.6.1.4.1.9.9.826.1.12.2.1.7

CfprComputeAssociation0 = none1 = establishing2 = associated3 = removing4 = failed5 = throttled · Integer32

Cisco Firepower compute:Blade:association managed object property

cfprComputeBladeAvailability

1.3.6.1.4.1.9.9.826.1.12.2.1.8

CfprComputeAvailability0 = unavailable1 = available · Integer32

Cisco Firepower compute:Blade:availability managed object property

cfprComputeBladeAvailableMemory

1.3.6.1.4.1.9.9.826.1.12.2.1.9

Gauge32

Cisco Firepower compute:Blade:availableMemory managed object property

cfprComputeBladeChassisId

1.3.6.1.4.1.9.9.826.1.12.2.1.10

Gauge32

Cisco Firepower compute:Blade:chassisId managed object property

cfprComputeBladeCheckPoint

1.3.6.1.4.1.9.9.826.1.12.2.1.11

CfprComputeCheckPoint0 = unknown1 = removing2 = shallowCheckpoint3 = deepCheckpoint4 = discovered · Integer32

Cisco Firepower compute:Blade:checkPoint managed object property

cfprComputeBladeConnPath

1.3.6.1.4.1.9.9.826.1.12.2.1.12

CfprEquipmentConnectionStatus · BITS

Cisco Firepower compute:Blade:connPath managed object property

cfprComputeBladeConnStatus

1.3.6.1.4.1.9.9.826.1.12.2.1.13

CfprEquipmentConnectionStatus · BITS

Cisco Firepower compute:Blade:connStatus managed object property

cfprComputeBladeDescr

1.3.6.1.4.1.9.9.826.1.12.2.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:descr managed object property

cfprComputeBladeDiscovery

1.3.6.1.4.1.9.9.826.1.12.2.1.15

CfprComputeDiscovery0 = undiscovered1 = inProgress2 = malformedFruInfo3 = fruNotReady4 = insufficientlyEquipped5 = invalidAdaptorIocard8 = failed16 = complete32 = retry64 = throttled128 = illegalFru129 = fruIdentityIndeterminate130 = fruStateIndeterminate131 = diagnosticsInProgress132 = efidiagnosticsInProgress133 = diagnosticsFailed134 = diagnosticsComplete135 = waitingForUserAck136 = userAcknowledged137 = waitingForMgmtAck138 = illegalPartNumber · Integer32

Cisco Firepower compute:Blade:discovery managed object property

cfprComputeBladeFltAggr

1.3.6.1.4.1.9.9.826.1.12.2.1.16

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:Blade:fltAggr managed object property

cfprComputeBladeFsmDescr

1.3.6.1.4.1.9.9.826.1.12.2.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:fsmDescr managed object property

cfprComputeBladeFsmFlags

1.3.6.1.4.1.9.9.826.1.12.2.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:fsmFlags managed object property

cfprComputeBladeFsmPrev

1.3.6.1.4.1.9.9.826.1.12.2.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:fsmPrev managed object property

cfprComputeBladeFsmProgr

1.3.6.1.4.1.9.9.826.1.12.2.1.20

Gauge32

Cisco Firepower compute:Blade:fsmProgr managed object property

cfprComputeBladeFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.12.2.1.21

Gauge32

Cisco Firepower compute:Blade:fsmRmtInvErrCode managed object property

cfprComputeBladeFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.12.2.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:fsmRmtInvErrDescr managed object property

cfprComputeBladeFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.12.2.1.23

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:Blade:fsmRmtInvRslt managed object property

cfprComputeBladeFsmStageDescr

1.3.6.1.4.1.9.9.826.1.12.2.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:fsmStageDescr managed object property

cfprComputeBladeFsmStamp

1.3.6.1.4.1.9.9.826.1.12.2.1.25

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:Blade:fsmStamp managed object property

cfprComputeBladeFsmStatus

1.3.6.1.4.1.9.9.826.1.12.2.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:fsmStatus managed object property

cfprComputeBladeFsmTry

1.3.6.1.4.1.9.9.826.1.12.2.1.27

Gauge32

Cisco Firepower compute:Blade:fsmTry managed object property

cfprComputeBladeIntId

1.3.6.1.4.1.9.9.826.1.12.2.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:intId managed object property

cfprComputeBladeLc

1.3.6.1.4.1.9.9.826.1.12.2.1.29

CfprComputeAdminTrigger0 = undiscovered1 = rediscover2 = resetToFactory3 = discovered4 = remove5 = migrate6 = decommission7 = upgradeFirmware8 = decommissionSecure · Integer32

Cisco Firepower compute:Blade:lc managed object property

cfprComputeBladeLcTs

1.3.6.1.4.1.9.9.826.1.12.2.1.30

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:Blade:lcTs managed object property

cfprComputeBladeLocalId

1.3.6.1.4.1.9.9.826.1.12.2.1.31

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:localId managed object property

cfprComputeBladeLowVoltageMemory

1.3.6.1.4.1.9.9.826.1.12.2.1.32

CfprComputePhysicalLowVoltageMemory0 = notApplicable1 = lowVoltage2 = regularVoltage · Integer32

Cisco Firepower compute:Blade:lowVoltageMemory managed object property

cfprComputeBladeManagingInst

1.3.6.1.4.1.9.9.826.1.12.2.1.33

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower compute:Blade:managingInst managed object property

cfprComputeBladeMemorySpeed

1.3.6.1.4.1.9.9.826.1.12.2.1.34

Gauge32

Cisco Firepower compute:Blade:memorySpeed managed object property

cfprComputeBladeMfgTime

1.3.6.1.4.1.9.9.826.1.12.2.1.35

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:Blade:mfgTime managed object property

cfprComputeBladeModel

1.3.6.1.4.1.9.9.826.1.12.2.1.36

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:model managed object property

cfprComputeBladeName

1.3.6.1.4.1.9.9.826.1.12.2.1.37

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:name managed object property

cfprComputeBladeNumOfAdaptors

1.3.6.1.4.1.9.9.826.1.12.2.1.38

Gauge32

Cisco Firepower compute:Blade:numOfAdaptors managed object property

cfprComputeBladeNumOfCores

1.3.6.1.4.1.9.9.826.1.12.2.1.39

Gauge32

Cisco Firepower compute:Blade:numOfCores managed object property

cfprComputeBladeNumOfCoresEnabled

1.3.6.1.4.1.9.9.826.1.12.2.1.40

Gauge32

Cisco Firepower compute:Blade:numOfCoresEnabled managed object property

cfprComputeBladeNumOfCpus

1.3.6.1.4.1.9.9.826.1.12.2.1.41

Gauge32

Cisco Firepower compute:Blade:numOfCpus managed object property

cfprComputeBladeNumOfEthHostIfs

1.3.6.1.4.1.9.9.826.1.12.2.1.42

Gauge32

Cisco Firepower compute:Blade:numOfEthHostIfs managed object property

cfprComputeBladeNumOfFcHostIfs

1.3.6.1.4.1.9.9.826.1.12.2.1.43

Gauge32

Cisco Firepower compute:Blade:numOfFcHostIfs managed object property

cfprComputeBladeNumOfThreads

1.3.6.1.4.1.9.9.826.1.12.2.1.44

Gauge32

Cisco Firepower compute:Blade:numOfThreads managed object property

cfprComputeBladeOperPower

1.3.6.1.4.1.9.9.826.1.12.2.1.45

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:Blade:operPower managed object property

cfprComputeBladeOperQualifier

1.3.6.1.4.1.9.9.826.1.12.2.1.46

CfprComputeIssues · BITS

Cisco Firepower compute:Blade:operQualifier managed object property

cfprComputeBladeOperState

1.3.6.1.4.1.9.9.826.1.12.2.1.47

CfprLsOperState0 = indeterminate1 = unassociated10 = ok11 = discovery12 = config13 = unconfig14 = powerOff15 = restart20 = maintenance21 = test29 = computeMismatch30 = computeFailed31 = degraded32 = discoveryFailed33 = configFailure34 = unconfigFailed35 = testFailed36 = maintenanceFailed40 = removed41 = disabled50 = inaccessible60 = thermalProblem61 = powerProblem62 = voltageProblem63 = inoperable101 = decomissioning102 = decomissioned201 = biosRestore202 = cmosReset203 = diagnostics204 = diagnosticsFailed210 = pendingReboot211 = pendingReassociation212 = svnicNotPresent · Integer32

Cisco Firepower compute:Blade:operState managed object property

cfprComputeBladeOperability

1.3.6.1.4.1.9.9.826.1.12.2.1.48

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:Blade:operability managed object property

cfprComputeBladeOriginalUuid

1.3.6.1.4.1.9.9.826.1.12.2.1.49

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:originalUuid managed object property

cfprComputeBladePartNumber

1.3.6.1.4.1.9.9.826.1.12.2.1.50

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:partNumber managed object property

cfprComputeBladePolicyLevel

1.3.6.1.4.1.9.9.826.1.12.2.1.51

Gauge32

Cisco Firepower compute:Blade:policyLevel managed object property

cfprComputeBladePolicyOwner

1.3.6.1.4.1.9.9.826.1.12.2.1.52

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:Blade:policyOwner managed object property

cfprComputeBladePresence

1.3.6.1.4.1.9.9.826.1.12.2.1.53

CfprEquipmentSlotStatus0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized · Integer32

Cisco Firepower compute:Blade:presence managed object property

cfprComputeBladeRevision

1.3.6.1.4.1.9.9.826.1.12.2.1.54

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:revision managed object property

cfprComputeBladeScaledMode

1.3.6.1.4.1.9.9.826.1.12.2.1.55

CfprComputeMode0 = none1 = single2 = scaled · Integer32

Cisco Firepower compute:Blade:scaledMode managed object property

cfprComputeBladeSerial

1.3.6.1.4.1.9.9.826.1.12.2.1.56

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:serial managed object property

cfprComputeBladeServerId

1.3.6.1.4.1.9.9.826.1.12.2.1.57

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:serverId managed object property

cfprComputeBladeSlotId

1.3.6.1.4.1.9.9.826.1.12.2.1.58

CfprComputeBladeSlotId (1..8) · Gauge32

Cisco Firepower compute:Blade:slotId managed object property

cfprComputeBladeTotalMemory

1.3.6.1.4.1.9.9.826.1.12.2.1.59

Gauge32

Cisco Firepower compute:Blade:totalMemory managed object property

cfprComputeBladeUpgradeScenario

1.3.6.1.4.1.9.9.826.1.12.2.1.60

CfprComputeUpgradeStatus0 = notUpgraded1 = upgraded2 = notApplicable · Integer32

Cisco Firepower compute:Blade:upgradeScenario managed object property

cfprComputeBladeUsrLbl

1.3.6.1.4.1.9.9.826.1.12.2.1.61

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:usrLbl managed object property

cfprComputeBladeUuid

1.3.6.1.4.1.9.9.826.1.12.2.1.62

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:uuid managed object property

cfprComputeBladeVendor

1.3.6.1.4.1.9.9.826.1.12.2.1.63

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:vendor managed object property

cfprComputeBladeVid

1.3.6.1.4.1.9.9.826.1.12.2.1.64

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:vid managed object property

cfprComputeBladeLastAdaptorCrashReset

1.3.6.1.4.1.9.9.826.1.12.2.1.65

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Blade:lastAdaptorCrashReset managed object property

cfprComputeBladeLastBiosHangReset

1.3.6.1.4.1.9.9.826.1.12.2.1.66

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:Blade:lastBiosHangReset managed object property

cfprComputeBladeLastCatErrReset

1.3.6.1.4.1.9.9.826.1.12.2.1.67

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:Blade:lastCatErrReset managed object property

cfprComputeBladePostState

1.3.6.1.4.1.9.9.826.1.12.2.1.68

CfprEquipmentBiosPostState0 = unknown1 = complete2 = notComplete3 = timeout · Integer32

Cisco Firepower compute:Blade:postState managed object property

cfprComputeBladePostWaitCount

1.3.6.1.4.1.9.9.826.1.12.2.1.69

Gauge32

Cisco Firepower compute:Blade:postWaitCount managed object property

cfprComputeBladeResetCatErrCount

1.3.6.1.4.1.9.9.826.1.12.2.1.70

Gauge32

Cisco Firepower compute:Blade:resetCatErrCount managed object property

cfprComputeBladeResetCount

1.3.6.1.4.1.9.9.826.1.12.2.1.71

Gauge32

Cisco Firepower compute:Blade:resetCount managed object property

cfprComputeBladeDiscPolicyTable

1.3.6.1.4.1.9.9.826.1.12.3

Index: cfprComputeBladeDiscPolicyInstanceId

Cisco Firepower compute:BladeDiscPolicy managed object table

cfprComputeBladeDiscPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.3.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBladeDiscPolicyDn

1.3.6.1.4.1.9.9.826.1.12.3.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BladeDiscPolicy:dn managed object property

cfprComputeBladeDiscPolicyRn

1.3.6.1.4.1.9.9.826.1.12.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:rn managed object property

cfprComputeBladeDiscPolicyAction

1.3.6.1.4.1.9.9.826.1.12.3.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:action managed object property

cfprComputeBladeDiscPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.3.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:descr managed object property

cfprComputeBladeDiscPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.3.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:intId managed object property

cfprComputeBladeDiscPolicyName

1.3.6.1.4.1.9.9.826.1.12.3.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:name managed object property

cfprComputeBladeDiscPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.3.1.8

Gauge32

Cisco Firepower compute:BladeDiscPolicy:policyLevel managed object property

cfprComputeBladeDiscPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.3.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:BladeDiscPolicy:policyOwner managed object property

cfprComputeBladeDiscPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.3.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:qualifier managed object property

cfprComputeBladeDiscPolicyScrubPolicyName

1.3.6.1.4.1.9.9.826.1.12.3.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeDiscPolicy:scrubPolicyName managed object property

cfprComputeBladeFsmTable

1.3.6.1.4.1.9.9.826.1.12.4

Index: cfprComputeBladeFsmInstanceId

Cisco Firepower compute:BladeFsm managed object table

cfprComputeBladeFsmInstanceId

1.3.6.1.4.1.9.9.826.1.12.4.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBladeFsmDn

1.3.6.1.4.1.9.9.826.1.12.4.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BladeFsm:dn managed object property

cfprComputeBladeFsmRn

1.3.6.1.4.1.9.9.826.1.12.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeFsm:rn managed object property

cfprComputeBladeFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.12.4.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:BladeFsm:completionTime managed object property

cfprComputeBladeFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.12.4.1.5

CfprComputeBladeFsmCurrentFsm0 = nop23 = discover144 = diag665 = associate727 = disassociate767 = powerCap769 = decommission771 = softShutdown773 = hardShutdown775 = turnup777 = powercycle781 = hardreset785 = softreset789 = swConnUpd792 = biosRecovery806 = cmosReset815 = resetBmc879 = updateExtUsers891 = updateAdaptor898 = activateAdaptor932 = configSoL934 = unconfigSoL1036 = diagnosticInterrupt1055 = resetKvm1152 = updateBIOS1157 = activateBIOS1200 = resetIpmi1202 = fwUpgrade1477 = cimcSessionDelete1497 = updateBoardController1506 = configBoard1508 = resetMemoryErrors1531 = serviceInfraDeploy1536 = serviceInfraWithdraw1638 = flashController1669 = enableCimcSecureBoot1991 = updateAdaptorBoot2035 = hardPowercycle · Integer32

Cisco Firepower compute:BladeFsm:currentFsm managed object property

cfprComputeBladeFsmDescrData

1.3.6.1.4.1.9.9.826.1.12.4.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeFsm:descr managed object property

cfprComputeBladeFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.12.4.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:BladeFsm:fsmStatus managed object property

cfprComputeBladeFsmProgress

1.3.6.1.4.1.9.9.826.1.12.4.1.8

Gauge32

Cisco Firepower compute:BladeFsm:progress managed object property

cfprComputeBladeFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.12.4.1.9

Gauge32

Cisco Firepower compute:BladeFsm:rmtErrCode managed object property

cfprComputeBladeFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.12.4.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeFsm:rmtErrDescr managed object property

cfprComputeBladeFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.12.4.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:BladeFsm:rmtRslt managed object property

cfprComputeBladeFsmStageTable

1.3.6.1.4.1.9.9.826.1.12.5

Index: cfprComputeBladeFsmStageInstanceId

Cisco Firepower compute:BladeFsmStage managed object table

cfprComputeBladeFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.12.5.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBladeFsmStageDn

1.3.6.1.4.1.9.9.826.1.12.5.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BladeFsmStage:dn managed object property

cfprComputeBladeFsmStageRn

1.3.6.1.4.1.9.9.826.1.12.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeFsmStage:rn managed object property

cfprComputeBladeFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.12.5.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeFsmStage:descr managed object property

cfprComputeBladeFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.12.5.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:BladeFsmStage:lastUpdateTime managed object property

cfprComputeBladeFsmStageName

1.3.6.1.4.1.9.9.826.1.12.5.1.6

CfprComputeBladeFsmStageName0 = nop23 = discoverBegin24 = discoverBmcPresence25 = discoverBmcInventory26 = discoverConfigFeLocal27 = discoverConfigFePeer28 = discoverConfigUserAccess29 = discoverBladePowerOn33 = discoverSwConfigPnuOSLocal34 = discoverSwConfigPnuOSPeer35 = discoverBladeBootPnuos36 = discoverBladeReadSmbios37 = discoverHagConnect38 = discoverPnuOSIdent39 = discoverPnuOSPolicy40 = discoverPnuOSInventory41 = discoverPnuOSSelfTest43 = discoverSwUnconfigPnuOSLocal44 = discoverSwUnconfigPnuOSPeer45 = discoverHagDisconnect46 = discoverBmcShutdownDiscovered47 = discoverHandlePooling48 = discoverSuccess49 = discoverFail144 = diagBegin145 = diagBmcPresence146 = diagBmcInventory147 = diagConfigFeLocal148 = diagConfigFePeer149 = diagBladePowerOn152 = diagDeriveConfig153 = diagConfigUserAccess155 = diagSwConfigLocal156 = diagSwConfigPeer158 = diagSetupVMediaLocal159 = diagSetupVMediaPeer160 = diagBladeBoot161 = diagBladeReadSmbios162 = diagHostConnect165 = diagHostIdent166 = diagHostPolicy167 = diagSetDiagUser168 = diagHostInventory171 = diagGenerateReport172 = diagRemoveConfig173 = diagRemoveVMediaLocal174 = diagRemoveVMediaPeer176 = diagSwUnconfigLocal177 = diagSwUnconfigPeer178 = diagUnconfigUserAccess180 = diagHostDisconnect181 = diagBmcShutdownDiagCompleted182 = diagSuccess183 = diagFail458 = discoverPnuOSScrub479 = diagHostServerDiag480 = diagHostServerDiagStatus481 = diagDisableServerConnSwB482 = diagStartFabricATrafficTest483 = diagFabricATrafficTestStatus484 = diagEnableServerConnSwB485 = diagDisableServerConnSwA486 = diagStartFabricBTrafficTest487 = diagFabricBTrafficTestStatus488 = diagEnableServerConnSwA504 = discoverBladeBootWait519 = diagBladeBootWait520 = diagBiosPostCompletion521 = discoverBiosPostCompletion526 = diagRestoreConfigFeLocal527 = diagRestoreConfigFePeer528 = discoverSetupVmediaLocal529 = discoverSetupVmediaPeer530 = discoverTeardownVmediaLocal531 = discoverTeardownVmediaPeer533 = diagGenerateLogWait534 = diagStopVMediaLocal535 = diagStopVMediaPeer545 = discoverSanitize567 = discoverPreSanitize591 = diagDebugWait599 = diagEvaluateStatus647 = diagNicPresenceLocal648 = diagNicPresencePeer649 = diagNicInventoryLocal650 = diagNicInventoryPeer651 = diagNicConfigLocal652 = diagNicConfigPeer653 = diagNicUnconfigLocal654 = diagNicUnconfigPeer657 = discoverNicPresenceLocal658 = discoverNicPresencePeer659 = discoverNicConfigPnuOSLocal660 = discoverNicConfigPnuOSPeer663 = discoverNicUnconfigPnuOSLocal664 = discoverNicUnconfigPnuOSPeer665 = associateBegin668 = associateUpdateIBMCFw669 = associateWaitForIBMCFwUpdate670 = associateActivateIBMCFw671 = associateResetIBMC672 = associatePreSanitize673 = associateSanitize674 = associateConfigUserAccess675 = associateBladePowerOff676 = associateUpdateBoardCtrlRequest677 = associatePollBoardCtrlUpdateStatus678 = associatePowerOn679 = associateBmcPreconfigPnuOSLocal680 = associateBmcPreconfigPnuOSPeer681 = associateBmcConfigPnuOS682 = associateSwConfigPnuOSLocal683 = associateSwConfigPnuOSPeer684 = associateUpdateAdaptorNwFwLocal685 = associateUpdateAdaptorNwFwPeer686 = associateWaitForAdaptorNwFwUpdateLocal687 = associateWaitForAdaptorNwFwUpdatePeer688 = associateActivateAdaptorNwFwLocal689 = associateActivateAdaptorNwFwPeer690 = associateNicConfigPnuOSLocal691 = associateNicConfigPnuOSPeer692 = associateBootPnuos693 = associateBootWait694 = associateBiosPostCompletion695 = associateHagPnuOSConnect696 = associatePnuOSIdent697 = associatePnuOSPolicy698 = associatePnuOSValidate699 = associatePnuOSSelfTest700 = associateBiosImgUpdate701 = associateStorageCtlrImgUpdate702 = associateHbaImgUpdate703 = associateNicImgUpdate704 = associatePnuOSInventory705 = associatePnuOSConfig706 = associatePnuOSLocalDiskConfig707 = associatePnuOSUnloadDrivers708 = associateBmcUnconfigPnuOS709 = associateNicUnconfigPnuOSLocal710 = associateNicUnconfigPnuOSPeer711 = associateSwUnconfigPnuOSLocal712 = associateSwUnconfigPnuOSPeer713 = associateSwConfigHostOSLocal714 = associateSwConfigHostOSPeer715 = associateNicConfigHostOSLocal716 = associateNicConfigHostOSPeer717 = associateHagPnuOSDisconnect718 = associateConfigSoL719 = associatePrepareForBoot720 = associateConfigUuid721 = associateBootHost722 = associateHagHostOSConnect723 = associateHostOSIdent724 = associateHostOSPolicy725 = associateHostOSValidate726 = associateHostOSConfig727 = disassociateBegin730 = disassociateConfigUserAccess731 = disassociatePowerOn732 = disassociatePreSanitize733 = disassociateSanitize734 = disassociateNicUnconfigHostOSLocal735 = disassociateNicUnconfigHostOSPeer736 = disassociateSwUnconfigHostOSLocal737 = disassociateSwUnconfigHostOSPeer738 = disassociateBmcPreconfigPnuOSLocal739 = disassociateBmcPreconfigPnuOSPeer740 = disassociateBmcConfigPnuOS741 = disassociateSwConfigPnuOSLocal742 = disassociateSwConfigPnuOSPeer743 = disassociateNicConfigPnuOSLocal744 = disassociateNicConfigPnuOSPeer745 = disassociateConfigBios746 = disassociateBootPnuos747 = disassociateBootWait748 = disassociateBiosPostCompletion749 = disassociateHagPnuOSConnect750 = disassociatePnuOSIdent751 = disassociatePnuOSPolicy752 = disassociatePnuOSValidate753 = disassociatePnuOSUnconfig754 = disassociatePnuOSScrub755 = disassociatePnuOSSelfTest756 = disassociateBmcUnconfigPnuOS757 = disassociateNicUnconfigPnuOSLocal758 = disassociateNicUnconfigPnuOSPeer759 = disassociateHagPnuOSDisconnect760 = disassociateUnconfigUuid761 = disassociateShutdown762 = disassociateUnconfigBios763 = disassociateSwUnconfigPnuOSLocal764 = disassociateSwUnconfigPnuOSPeer765 = disassociateUnconfigSoL766 = disassociateHandlePooling767 = powerCapBegin768 = powerCapConfig769 = decommissionBegin770 = decommissionExecute771 = softShutdownBegin772 = softShutdownExecute773 = hardShutdownBegin774 = hardShutdownExecute775 = turnupBegin776 = turnupExecute777 = powercycleBegin778 = powercyclePreSanitize779 = powercycleSanitize780 = powercycleExecute781 = hardresetBegin782 = hardresetPreSanitize783 = hardresetSanitize784 = hardresetExecute785 = softresetBegin786 = softresetPreSanitize787 = softresetSanitize788 = softresetExecute789 = swConnUpdBegin790 = swConnUpdA791 = swConnUpdB792 = biosRecoveryBegin793 = biosRecoveryShutdown794 = biosRecoveryPreSanitize795 = biosRecoverySanitize796 = biosRecoverySetupVmediaLocal797 = biosRecoverySetupVmediaPeer798 = biosRecoveryStart799 = biosRecoveryWait800 = biosRecoveryCleanup801 = biosRecoveryReset802 = biosRecoveryTeardownVmediaLocal803 = biosRecoveryTeardownVmediaPeer806 = cmosResetBegin807 = cmosResetPreSanitize808 = cmosResetSanitize809 = cmosResetExecute810 = cmosResetReconfigBios811 = cmosResetReconfigUuid812 = cmosResetBladePowerOn815 = resetBmcBegin816 = resetBmcExecute879 = updateExtUsersBegin880 = updateExtUsersDeploy891 = updateAdaptorBegin892 = updateAdaptorPowerOn893 = updateAdaptorUpdateRequestLocal894 = updateAdaptorUpdateRequestPeer895 = updateAdaptorPollUpdateStatusLocal896 = updateAdaptorPollUpdateStatusPeer897 = updateAdaptorPowerOff898 = activateAdaptorBegin899 = activateAdaptorPowerOn900 = activateAdaptorActivateLocal901 = activateAdaptorActivatePeer902 = activateAdaptorReset932 = configSoLBegin933 = configSoLExecute934 = unconfigSoLBegin935 = unconfigSoLExecute940 = activateAdaptorFail941 = activateAdaptorSuccess942 = associateFail943 = associateSuccess946 = biosRecoveryFail947 = biosRecoverySuccess948 = cmosResetFail949 = cmosResetSuccess950 = configSoLFail951 = configSoLSuccess952 = decommissionFail953 = decommissionSuccess954 = disassociateFail955 = disassociateSuccess956 = hardShutdownFail957 = hardShutdownSuccess958 = hardresetFail959 = hardresetSuccess960 = powerCapFail961 = powerCapSuccess962 = powercycleFail963 = powercycleSuccess964 = resetBmcFail965 = resetBmcSuccess966 = softShutdownFail967 = softShutdownSuccess968 = softresetFail969 = softresetSuccess970 = swConnUpdFail971 = swConnUpdSuccess972 = turnupFail973 = turnupSuccess974 = unconfigSoLFail975 = unconfigSoLSuccess976 = updateAdaptorFail977 = updateAdaptorSuccess978 = updateExtUsersFail979 = updateExtUsersSuccess1019 = decommissionStopVMediaLocal1020 = decommissionStopVMediaPeer1021 = biosRecoveryStopVMediaLocal1022 = biosRecoveryStopVMediaPeer1032 = diagCleanupServerConnSwA1033 = diagCleanupServerConnSwB1036 = diagnosticInterruptBegin1037 = diagnosticInterruptExecute1038 = diagnosticInterruptFail1039 = diagnosticInterruptSuccess1040 = associateLocalDiskFwUpdate1055 = resetKvmBegin1056 = resetKvmExecute1057 = resetKvmFail1058 = resetKvmSuccess1069 = associateSwConfigPortNivLocal1070 = associateSwConfigPortNivPeer1071 = disassociateSwConfigPortNivLocal1072 = disassociateSwConfigPortNivPeer1078 = discoverBmcPreConfigPnuOSLocal1079 = discoverBmcPreConfigPnuOSPeer1080 = discoverBmcConfigPnuOS1089 = diagBmcConfigPnuOS1096 = diagSolRedirectEnable1097 = diagSerialDebugConnect1098 = diagSerialDebugDisconnect1099 = diagSolRedirectDisable1100 = discoverSolRedirectEnable1101 = discoverSerialDebugConnect1102 = discoverSerialDebugDisconnect1103 = discoverSolRedirectDisable1104 = associateSolRedirectEnable1105 = associateSerialDebugPnuOSConnect1106 = associateSerialDebugPnuOSDisconnect1107 = associateSolRedirectDisable1108 = disassociateSolRedirectEnable1109 = disassociateSerialDebugPnuOSConnect1110 = disassociateSerialDebugPnuOSDisconnect1111 = disassociateSolRedirectDisable1112 = decommissionCleanupCIMC1152 = updateBIOSBegin1153 = updateBIOSClear1154 = updateBIOSPollClearStatus1155 = updateBIOSUpdateRequest1156 = updateBIOSPollUpdateStatus1157 = activateBIOSBegin1158 = activateBIOSPowerOff1159 = activateBIOSClear1160 = activateBIOSPollClearStatus1161 = activateBIOSActivate1162 = activateBIOSPollActivateStatus1163 = activateBIOSUpdateTokens1164 = activateBIOSPowerOn1167 = diagHostCatalog1168 = discoverPnuOSCatalog1169 = associateClearBiosUpdate1170 = associatePollClearBiosUpdateStatus1171 = associateUpdateBiosRequest1172 = associatePollBiosUpdateStatus1173 = associateActivateBios1174 = associatePollBiosActivateStatus1175 = associatePnuOSCatalog1176 = disassociatePnuOSCatalog1178 = activateBIOSFail1179 = activateBIOSSuccess1180 = updateBIOSFail1181 = updateBIOSSuccess1193 = associateMarkAdapterForReboot1194 = associateDeassertResetBypass1195 = associateVerifyFcZoneConfig1196 = disassociateDeassertResetBypass1197 = disassociateVerifyFcZoneConfig1198 = decommissionCleanupPortConfigLocal1199 = decommissionCleanupPortConfigPeer1200 = resetIpmiBegin1201 = resetIpmiExecute1202 = fwUpgradeBegin1203 = fwUpgradeUpdateIBMCFw1204 = fwUpgradeWaitForIBMCFwUpdate1205 = fwUpgradeActivateIBMCFw1206 = fwUpgradeResetIBMC1207 = fwUpgradePreSanitize1208 = fwUpgradeSanitize1209 = fwUpgradeBladePowerOff1210 = fwUpgradeUpdateBoardCtrlRequest1211 = fwUpgradePollBoardCtrlUpdateStatus1212 = fwUpgradeClearBiosUpdate1213 = fwUpgradePollClearBiosUpdateStatus1214 = fwUpgradeUpdateBiosRequest1215 = fwUpgradePollBiosUpdateStatus1216 = fwUpgradeActivateBios1217 = fwUpgradePollBiosActivateStatus1218 = fwUpgradePowerOn1219 = fwUpgradeBmcPreconfigPnuOSLocal1220 = fwUpgradeBmcPreconfigPnuOSPeer1221 = fwUpgradeSwConfigPortNivLocal1222 = fwUpgradeSwConfigPortNivPeer1223 = fwUpgradeSwConfigPnuOSLocal1224 = fwUpgradeSwConfigPnuOSPeer1225 = fwUpgradeUpdateAdaptorNwFwLocal1226 = fwUpgradeUpdateAdaptorNwFwPeer1227 = fwUpgradeWaitForAdaptorNwFwUpdateLocal1228 = fwUpgradeWaitForAdaptorNwFwUpdatePeer1229 = fwUpgradeActivateAdaptorNwFwLocal1230 = fwUpgradeActivateAdaptorNwFwPeer1231 = fwUpgradeNicConfigPnuOSLocal1232 = fwUpgradeNicConfigPnuOSPeer1233 = fwUpgradeBmcConfigPnuOS1234 = fwUpgradeSolRedirectEnable1235 = fwUpgradeSerialDebugPnuOSConnect1236 = fwUpgradeBootPnuos1237 = fwUpgradeBootWait1238 = fwUpgradeBiosPostCompletion1239 = fwUpgradeHagPnuOSConnect1240 = fwUpgradePnuOSIdent1241 = fwUpgradePnuOSPolicy1242 = fwUpgradePnuOSCatalog1243 = fwUpgradePnuOSValidate1244 = fwUpgradePnuOSSelfTest1245 = fwUpgradeStorageCtlrImgUpdate1246 = fwUpgradeHbaImgUpdate1247 = fwUpgradeNicImgUpdate1248 = fwUpgradeLocalDiskFwUpdate1249 = fwUpgradePnuOSConfig1250 = fwUpgradePnuOSInventory1251 = fwUpgradeBiosImgUpdate1252 = fwUpgradePnuOSUnloadDrivers1253 = fwUpgradeBmcUnconfigPnuOS1254 = fwUpgradeNicUnconfigPnuOSLocal1255 = fwUpgradeNicUnconfigPnuOSPeer1256 = fwUpgradeSwUnconfigPnuOSLocal1257 = fwUpgradeSwUnconfigPnuOSPeer1258 = fwUpgradeDeassertResetBypass1259 = fwUpgradeHagPnuOSDisconnect1260 = fwUpgradeSerialDebugPnuOSDisconnect1261 = fwUpgradeSolRedirectDisable1262 = fwUpgradeShutdown1307 = activateAdaptorDeassertResetBypass1386 = fwUpgradeFail1387 = fwUpgradeSuccess1388 = resetIpmiFail1389 = resetIpmiSuccess1468 = associateConfigFlexFlash1469 = associateSyncPowerState1470 = disassociateUnconfigFlexFlash1477 = cimcSessionDeleteBegin1478 = cimcSessionDeleteExecute1483 = cimcSessionDeleteFail1484 = cimcSessionDeleteSuccess1497 = updateBoardControllerBegin1498 = updateBoardControllerPrepareForUpdate1499 = updateBoardControllerServerPowerOff1500 = updateBoardControllerUpdateRequest1501 = updateBoardControllerPollUpdateStatus1502 = updateBoardControllerServerPowerOn1506 = configBoardBegin1507 = configBoardConfigMemoryPolicy1508 = resetMemoryErrorsBegin1509 = resetMemoryErrorsExecute1518 = discoverOobStorageInventory1519 = discoverConfigFlexFlashScrub1520 = associateOobStorageInventory1521 = associateSwConfigServiceInfraLocal1522 = associateSwConfigServiceInfraPeer1523 = associateNicConfigServiceInfraLocal1524 = associateNicConfigServiceInfraPeer1525 = disassociateNicUnconfigServiceInfraLocal1526 = disassociateNicUnconfigServiceInfraPeer1527 = disassociateConfigFlexFlashScrub1531 = serviceInfraDeployBegin1532 = serviceInfraDeploySwConfigLocal1533 = serviceInfraDeploySwConfigPeer1534 = serviceInfraDeployNicConfigLocal1535 = serviceInfraDeployNicConfigPeer1536 = serviceInfraWithdrawBegin1537 = serviceInfraWithdrawSwUnConfigLocal1538 = serviceInfraWithdrawSwUnConfigPeer1539 = serviceInfraWithdrawNicUnConfigLocal1540 = serviceInfraWithdrawNicUnConfigPeer1541 = configBoardFail1542 = configBoardSuccess1543 = resetMemoryErrorsFail1544 = resetMemoryErrorsSuccess1545 = serviceInfraDeployFail1546 = serviceInfraDeploySuccess1547 = serviceInfraWithdrawFail1548 = serviceInfraWithdrawSuccess1549 = updateBoardControllerFail1550 = updateBoardControllerSuccess1561 = associatePowerOnPreConfig1562 = disassociateResetSecureBootConfig1567 = discoverConfigBMCPowerParams1568 = discoverCheckPowerAvailability1569 = discoverSendBmcProfilingInit1570 = discoverPnuOSPowerProfiling1571 = discoverSendBmcProfilingDone1572 = associateDownloadImages1573 = associateCopyRemote1574 = associateCheckPowerAvailability1575 = associateDeleteCurlDownloadedImages1576 = fwUpgradeDownloadImages1577 = fwUpgradeCopyRemote1578 = fwUpgradeDeleteCurlDownloadedImages1597 = updateAdaptorCheckPowerAvailability1598 = updateAdaptorPowerDeployWait1599 = activateAdaptorCheckPowerAvailability1600 = activateAdaptorPowerDeployWait1601 = discoverPowerDeployWait1602 = associatePowerDeployWait1603 = disassociateCheckPowerAvailability1604 = disassociatePowerDeployWait1605 = fwUpgradeCheckPowerAvailability1606 = fwUpgradePowerDeployWait1617 = discoverUnconfigExtMgmtRules1618 = discoverUnconfigExtMgmtGw1619 = discoverUnconfigCimcVMedia1620 = associateUnconfigExtMgmtRules1621 = associateUnconfigExtMgmtGw1622 = associateUnconfigCimcVMedia1623 = associateGraphicsImageUpdate1624 = associateConfigExtMgmtRules1625 = associateConfigExtMgmtGw1626 = associateConfigCimcVMedia1627 = associateSspUpdateHostPreBoot1628 = disassociateConfigKvmMgmtDefaultSetting1629 = disassociateUnconfigExtMgmtRules1630 = disassociateUnconfigExtMgmtGw1631 = disassociateUnconfigCimcVMedia1632 = decommissionUnconfigExtMgmtRules1633 = decommissionUnconfigExtMgmtGw1634 = fwUpgradeUnconfigExtMgmtRules1635 = fwUpgradeUnconfigExtMgmtGw1636 = fwUpgradeUnconfigCimcVMedia1637 = fwUpgradeGraphicsImageUpdate1638 = flashControllerBegin1639 = flashControllerUpdateFlashLife1653 = flashControllerFail1654 = flashControllerSuccess1669 = enableCimcSecureBootBegin1670 = enableCimcSecureBootUpdateRequest1671 = enableCimcSecureBootPollUpdateStatus1672 = enableCimcSecureBootActivate1673 = enableCimcSecureBootReset1676 = enableCimcSecureBootFail1677 = enableCimcSecureBootSuccess1710 = discoverPrepareKeyFile1711 = associateUpdateSspOsSoftware1712 = associateWaitForSspOsUpdateComplete1713 = associatePrepareKeyFile1991 = updateAdaptorBootBegin1992 = updateAdaptorBootCheckPowerAvailability1993 = updateAdaptorBootPowerDeployWait1994 = updateAdaptorBootPowerOn1995 = updateAdaptorBootUpdateRequestLocal1996 = updateAdaptorBootUpdateRequestPeer1997 = updateAdaptorBootPollUpdateStatusLocal1998 = updateAdaptorBootPollUpdateStatusPeer1999 = updateAdaptorBootPowerOff2000 = updateAdaptorBootFail2001 = updateAdaptorBootSuccess2035 = hardPowercycleBegin2036 = hardPowercycleExecute2068 = hardPowercycleFail2069 = hardPowercycleSuccess · Integer32

Cisco Firepower compute:BladeFsmStage:name managed object property

cfprComputeBladeFsmStageOrder

1.3.6.1.4.1.9.9.826.1.12.5.1.7

Gauge32

Cisco Firepower compute:BladeFsmStage:order managed object property

cfprComputeBladeFsmStageRetry

1.3.6.1.4.1.9.9.826.1.12.5.1.8

Gauge32

Cisco Firepower compute:BladeFsmStage:retry managed object property

cfprComputeBladeFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.12.5.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:BladeFsmStage:stageStatus managed object property

cfprComputeBladeFsmTaskTable

1.3.6.1.4.1.9.9.826.1.12.6

Index: cfprComputeBladeFsmTaskInstanceId

Cisco Firepower compute:BladeFsmTask managed object table

cfprComputeBladeFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.12.6.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBladeFsmTaskDn

1.3.6.1.4.1.9.9.826.1.12.6.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BladeFsmTask:dn managed object property

cfprComputeBladeFsmTaskRn

1.3.6.1.4.1.9.9.826.1.12.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeFsmTask:rn managed object property

cfprComputeBladeFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.12.6.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower compute:BladeFsmTask:completion managed object property

cfprComputeBladeFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.12.6.1.5

CfprComputeBladeFsmTaskFlags · BITS

Cisco Firepower compute:BladeFsmTask:flags managed object property

cfprComputeBladeFsmTaskItem

1.3.6.1.4.1.9.9.826.1.12.6.1.6

CfprComputeBladeFsmTaskItem0 = nop23 = discover144 = diag · Integer32

Cisco Firepower compute:BladeFsmTask:item managed object property

cfprComputeBladeFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.12.6.1.7

Gauge32

Cisco Firepower compute:BladeFsmTask:seqId managed object property

cfprComputeBladeInheritPolicyTable

1.3.6.1.4.1.9.9.826.1.12.7

Index: cfprComputeBladeInheritPolicyInstanceId

Cisco Firepower compute:BladeInheritPolicy managed object table

cfprComputeBladeInheritPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.7.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBladeInheritPolicyDn

1.3.6.1.4.1.9.9.826.1.12.7.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BladeInheritPolicy:dn managed object property

cfprComputeBladeInheritPolicyRn

1.3.6.1.4.1.9.9.826.1.12.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeInheritPolicy:rn managed object property

cfprComputeBladeInheritPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.7.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeInheritPolicy:descr managed object property

cfprComputeBladeInheritPolicyDstDn

1.3.6.1.4.1.9.9.826.1.12.7.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeInheritPolicy:dstDn managed object property

cfprComputeBladeInheritPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.7.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeInheritPolicy:intId managed object property

cfprComputeBladeInheritPolicyName

1.3.6.1.4.1.9.9.826.1.12.7.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeInheritPolicy:name managed object property

cfprComputeBladeInheritPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.7.1.8

Gauge32

Cisco Firepower compute:BladeInheritPolicy:policyLevel managed object property

cfprComputeBladeInheritPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.7.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:BladeInheritPolicy:policyOwner managed object property

cfprComputeBladeInheritPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.7.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BladeInheritPolicy:qualifier managed object property

cfprComputeBoardTable

1.3.6.1.4.1.9.9.826.1.12.8

Index: cfprComputeBoardInstanceId

Cisco Firepower compute:Board managed object table

cfprComputeBoardInstanceId

1.3.6.1.4.1.9.9.826.1.12.8.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBoardDn

1.3.6.1.4.1.9.9.826.1.12.8.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Board:dn managed object property

cfprComputeBoardRn

1.3.6.1.4.1.9.9.826.1.12.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:rn managed object property

cfprComputeBoardCmosVoltage

1.3.6.1.4.1.9.9.826.1.12.8.1.4

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:Board:cmosVoltage managed object property

cfprComputeBoardCpuType

1.3.6.1.4.1.9.9.826.1.12.8.1.5

CfprEquipmentCpuType0 = other1 = ivyBridge2 = sandyBridge · Integer32

Cisco Firepower compute:Board:cpuType managed object property

cfprComputeBoardFaultQualifier

1.3.6.1.4.1.9.9.826.1.12.8.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:faultQualifier managed object property

cfprComputeBoardId

1.3.6.1.4.1.9.9.826.1.12.8.1.7

Gauge32

Cisco Firepower compute:Board:id managed object property

cfprComputeBoardLocationDn

1.3.6.1.4.1.9.9.826.1.12.8.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:locationDn managed object property

cfprComputeBoardModel

1.3.6.1.4.1.9.9.826.1.12.8.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:model managed object property

cfprComputeBoardOperPower

1.3.6.1.4.1.9.9.826.1.12.8.1.10

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:Board:operPower managed object property

cfprComputeBoardOperQualifierReason

1.3.6.1.4.1.9.9.826.1.12.8.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:operQualifierReason managed object property

cfprComputeBoardOperState

1.3.6.1.4.1.9.9.826.1.12.8.1.12

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:Board:operState managed object property

cfprComputeBoardOperability

1.3.6.1.4.1.9.9.826.1.12.8.1.13

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:Board:operability managed object property

cfprComputeBoardPerf

1.3.6.1.4.1.9.9.826.1.12.8.1.14

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:Board:perf managed object property

cfprComputeBoardPower

1.3.6.1.4.1.9.9.826.1.12.8.1.15

CfprComputeABoardPower0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:Board:power managed object property

cfprComputeBoardPowerUsage

1.3.6.1.4.1.9.9.826.1.12.8.1.16

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:Board:powerUsage managed object property

cfprComputeBoardPresence

1.3.6.1.4.1.9.9.826.1.12.8.1.17

CfprEquipmentPresence0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized100 = notSupported · Integer32

Cisco Firepower compute:Board:presence managed object property

cfprComputeBoardRevision

1.3.6.1.4.1.9.9.826.1.12.8.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:revision managed object property

cfprComputeBoardSerial

1.3.6.1.4.1.9.9.826.1.12.8.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:serial managed object property

cfprComputeBoardThermal

1.3.6.1.4.1.9.9.826.1.12.8.1.20

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:Board:thermal managed object property

cfprComputeBoardVendor

1.3.6.1.4.1.9.9.826.1.12.8.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Board:vendor managed object property

cfprComputeBoardVoltage

1.3.6.1.4.1.9.9.826.1.12.8.1.22

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:Board:voltage managed object property

cfprComputeBoardConnectorTable

1.3.6.1.4.1.9.9.826.1.12.9

Index: cfprComputeBoardConnectorInstanceId

Cisco Firepower compute:BoardConnector managed object table

cfprComputeBoardConnectorInstanceId

1.3.6.1.4.1.9.9.826.1.12.9.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBoardConnectorDn

1.3.6.1.4.1.9.9.826.1.12.9.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BoardConnector:dn managed object property

cfprComputeBoardConnectorRn

1.3.6.1.4.1.9.9.826.1.12.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardConnector:rn managed object property

cfprComputeBoardConnectorBoardConnectorType

1.3.6.1.4.1.9.9.826.1.12.9.1.4

CfprEquipmentBoardConnectorType1 = connUnlinked2 = connLinked · Integer32

Cisco Firepower compute:BoardConnector:boardConnectorType managed object property

cfprComputeBoardConnectorMasterSlotId

1.3.6.1.4.1.9.9.826.1.12.9.1.5

Gauge32

Cisco Firepower compute:BoardConnector:masterSlotId managed object property

cfprComputeBoardConnectorSlaveSlotId

1.3.6.1.4.1.9.9.826.1.12.9.1.6

Gauge32

Cisco Firepower compute:BoardConnector:slaveSlotId managed object property

cfprComputeBoardControllerTable

1.3.6.1.4.1.9.9.826.1.12.10

Index: cfprComputeBoardControllerInstanceId

Cisco Firepower compute:BoardController managed object table

cfprComputeBoardControllerInstanceId

1.3.6.1.4.1.9.9.826.1.12.10.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeBoardControllerDn

1.3.6.1.4.1.9.9.826.1.12.10.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:BoardController:dn managed object property

cfprComputeBoardControllerRn

1.3.6.1.4.1.9.9.826.1.12.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:rn managed object property

cfprComputeBoardControllerId

1.3.6.1.4.1.9.9.826.1.12.10.1.4

Gauge32

Cisco Firepower compute:BoardController:id managed object property

cfprComputeBoardControllerLocationDn

1.3.6.1.4.1.9.9.826.1.12.10.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:locationDn managed object property

cfprComputeBoardControllerModel

1.3.6.1.4.1.9.9.826.1.12.10.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:model managed object property

cfprComputeBoardControllerOperQualifierReason

1.3.6.1.4.1.9.9.826.1.12.10.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:operQualifierReason managed object property

cfprComputeBoardControllerOperState

1.3.6.1.4.1.9.9.826.1.12.10.1.8

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:BoardController:operState managed object property

cfprComputeBoardControllerOperability

1.3.6.1.4.1.9.9.826.1.12.10.1.9

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:BoardController:operability managed object property

cfprComputeBoardControllerPerf

1.3.6.1.4.1.9.9.826.1.12.10.1.10

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:BoardController:perf managed object property

cfprComputeBoardControllerPower

1.3.6.1.4.1.9.9.826.1.12.10.1.11

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:BoardController:power managed object property

cfprComputeBoardControllerPresence

1.3.6.1.4.1.9.9.826.1.12.10.1.12

CfprEquipmentPresence0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized100 = notSupported · Integer32

Cisco Firepower compute:BoardController:presence managed object property

cfprComputeBoardControllerRevision

1.3.6.1.4.1.9.9.826.1.12.10.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:revision managed object property

cfprComputeBoardControllerSerial

1.3.6.1.4.1.9.9.826.1.12.10.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:serial managed object property

cfprComputeBoardControllerThermal

1.3.6.1.4.1.9.9.826.1.12.10.1.15

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:BoardController:thermal managed object property

cfprComputeBoardControllerVendor

1.3.6.1.4.1.9.9.826.1.12.10.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:BoardController:vendor managed object property

cfprComputeBoardControllerVoltage

1.3.6.1.4.1.9.9.826.1.12.10.1.17

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:BoardController:voltage managed object property

cfprComputeChassisConnPolicyTable

1.3.6.1.4.1.9.9.826.1.12.11

Index: cfprComputeChassisConnPolicyInstanceId

Cisco Firepower compute:ChassisConnPolicy managed object table

cfprComputeChassisConnPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.11.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeChassisConnPolicyDn

1.3.6.1.4.1.9.9.826.1.12.11.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ChassisConnPolicy:dn managed object property

cfprComputeChassisConnPolicyRn

1.3.6.1.4.1.9.9.826.1.12.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisConnPolicy:rn managed object property

cfprComputeChassisConnPolicyAdminState

1.3.6.1.4.1.9.9.826.1.12.11.1.4

CfprComputeAdminLinkAggregation0 = none1 = portChannel2 = global · Integer32

Cisco Firepower compute:ChassisConnPolicy:adminState managed object property

cfprComputeChassisConnPolicyChassisId

1.3.6.1.4.1.9.9.826.1.12.11.1.5

CfprComputeChassisConnPolicyChassisId (1..255) · Gauge32

Cisco Firepower compute:ChassisConnPolicy:chassisId managed object property

cfprComputeChassisConnPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.11.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisConnPolicy:descr managed object property

cfprComputeChassisConnPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.11.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisConnPolicy:intId managed object property

cfprComputeChassisConnPolicyName

1.3.6.1.4.1.9.9.826.1.12.11.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisConnPolicy:name managed object property

cfprComputeChassisConnPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.11.1.9

Gauge32

Cisco Firepower compute:ChassisConnPolicy:policyLevel managed object property

cfprComputeChassisConnPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.11.1.10

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:ChassisConnPolicy:policyOwner managed object property

cfprComputeChassisConnPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.11.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisConnPolicy:qualifier managed object property

cfprComputeChassisConnPolicySwitchId

1.3.6.1.4.1.9.9.826.1.12.11.1.12

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower compute:ChassisConnPolicy:switchId managed object property

cfprComputeChassisDiscPolicyTable

1.3.6.1.4.1.9.9.826.1.12.12

Index: cfprComputeChassisDiscPolicyInstanceId

Cisco Firepower compute:ChassisDiscPolicy managed object table

cfprComputeChassisDiscPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.12.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeChassisDiscPolicyDn

1.3.6.1.4.1.9.9.826.1.12.12.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ChassisDiscPolicy:dn managed object property

cfprComputeChassisDiscPolicyRn

1.3.6.1.4.1.9.9.826.1.12.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisDiscPolicy:rn managed object property

cfprComputeChassisDiscPolicyAction

1.3.6.1.4.1.9.9.826.1.12.12.1.4

CfprComputeChassisDiscAction0 = immediate1 = userAcknowledged2 = n1Link3 = n2Link4 = n4Link5 = n8Link6 = platformMax · Integer32

Cisco Firepower compute:ChassisDiscPolicy:action managed object property

cfprComputeChassisDiscPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.12.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisDiscPolicy:descr managed object property

cfprComputeChassisDiscPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.12.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisDiscPolicy:intId managed object property

cfprComputeChassisDiscPolicyLinkAggregationPref

1.3.6.1.4.1.9.9.826.1.12.12.1.7

CfprComputeLinkAggregation0 = none1 = portChannel · Integer32

Cisco Firepower compute:ChassisDiscPolicy:linkAggregationPref managed object property

cfprComputeChassisDiscPolicyName

1.3.6.1.4.1.9.9.826.1.12.12.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisDiscPolicy:name managed object property

cfprComputeChassisDiscPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.12.1.9

Gauge32

Cisco Firepower compute:ChassisDiscPolicy:policyLevel managed object property

cfprComputeChassisDiscPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.12.1.10

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:ChassisDiscPolicy:policyOwner managed object property

cfprComputeChassisDiscPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.12.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisDiscPolicy:qualifier managed object property

cfprComputeChassisDiscPolicyRebalance

1.3.6.1.4.1.9.9.826.1.12.12.1.12

CfprComputeConnectivityRebalancing0 = immediate1 = userAcknowledged · Integer32

Cisco Firepower compute:ChassisDiscPolicy:rebalance managed object property

cfprComputeChassisQualTable

1.3.6.1.4.1.9.9.826.1.12.13

Index: cfprComputeChassisQualInstanceId

Cisco Firepower compute:ChassisQual managed object table

cfprComputeChassisQualInstanceId

1.3.6.1.4.1.9.9.826.1.12.13.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeChassisQualDn

1.3.6.1.4.1.9.9.826.1.12.13.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ChassisQual:dn managed object property

cfprComputeChassisQualRn

1.3.6.1.4.1.9.9.826.1.12.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ChassisQual:rn managed object property

cfprComputeChassisQualMaxId

1.3.6.1.4.1.9.9.826.1.12.13.1.4

CfprComputeChassisQualMaxId (1..255) · Gauge32

Cisco Firepower compute:ChassisQual:maxId managed object property

cfprComputeChassisQualMinId

1.3.6.1.4.1.9.9.826.1.12.13.1.5

CfprComputeChassisQualMinId (1..255) · Gauge32

Cisco Firepower compute:ChassisQual:minId managed object property

cfprComputeDefaultsTable

1.3.6.1.4.1.9.9.826.1.12.14

Index: cfprComputeDefaultsInstanceId

Cisco Firepower compute:Defaults managed object table

cfprComputeDefaultsInstanceId

1.3.6.1.4.1.9.9.826.1.12.14.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeDefaultsDn

1.3.6.1.4.1.9.9.826.1.12.14.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Defaults:dn managed object property

cfprComputeDefaultsRn

1.3.6.1.4.1.9.9.826.1.12.14.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Defaults:rn managed object property

cfprComputeExtBoardTable

1.3.6.1.4.1.9.9.826.1.12.15

Index: cfprComputeExtBoardInstanceId

Cisco Firepower compute:ExtBoard managed object table

cfprComputeExtBoardInstanceId

1.3.6.1.4.1.9.9.826.1.12.15.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeExtBoardDn

1.3.6.1.4.1.9.9.826.1.12.15.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ExtBoard:dn managed object property

cfprComputeExtBoardRn

1.3.6.1.4.1.9.9.826.1.12.15.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:rn managed object property

cfprComputeExtBoardBoardAggregationRole

1.3.6.1.4.1.9.9.826.1.12.15.1.4

CfprEquipmentBoardAggregationRole0 = none1 = single2 = multiMaster3 = multiSlave · Integer32

Cisco Firepower compute:ExtBoard:boardAggregationRole managed object property

cfprComputeExtBoardChassisId

1.3.6.1.4.1.9.9.826.1.12.15.1.5

Gauge32

Cisco Firepower compute:ExtBoard:chassisId managed object property

cfprComputeExtBoardCmosVoltage

1.3.6.1.4.1.9.9.826.1.12.15.1.6

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:cmosVoltage managed object property

cfprComputeExtBoardConnPath

1.3.6.1.4.1.9.9.826.1.12.15.1.7

CfprEquipmentConnectionStatus · BITS

Cisco Firepower compute:ExtBoard:connPath managed object property

cfprComputeExtBoardConnStatus

1.3.6.1.4.1.9.9.826.1.12.15.1.8

CfprEquipmentConnectionStatus · BITS

Cisco Firepower compute:ExtBoard:connStatus managed object property

cfprComputeExtBoardFaultQualifier

1.3.6.1.4.1.9.9.826.1.12.15.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:faultQualifier managed object property

cfprComputeExtBoardId

1.3.6.1.4.1.9.9.826.1.12.15.1.10

Gauge32

Cisco Firepower compute:ExtBoard:id managed object property

cfprComputeExtBoardLocationDn

1.3.6.1.4.1.9.9.826.1.12.15.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:locationDn managed object property

cfprComputeExtBoardManagingInst

1.3.6.1.4.1.9.9.826.1.12.15.1.12

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower compute:ExtBoard:managingInst managed object property

cfprComputeExtBoardModel

1.3.6.1.4.1.9.9.826.1.12.15.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:model managed object property

cfprComputeExtBoardOperPower

1.3.6.1.4.1.9.9.826.1.12.15.1.14

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:operPower managed object property

cfprComputeExtBoardOperQualifierReason

1.3.6.1.4.1.9.9.826.1.12.15.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:operQualifierReason managed object property

cfprComputeExtBoardOperState

1.3.6.1.4.1.9.9.826.1.12.15.1.16

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:ExtBoard:operState managed object property

cfprComputeExtBoardOperability

1.3.6.1.4.1.9.9.826.1.12.15.1.17

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:ExtBoard:operability managed object property

cfprComputeExtBoardPerf

1.3.6.1.4.1.9.9.826.1.12.15.1.18

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:perf managed object property

cfprComputeExtBoardPower

1.3.6.1.4.1.9.9.826.1.12.15.1.19

CfprComputeABoardPower0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:power managed object property

cfprComputeExtBoardPowerUsage

1.3.6.1.4.1.9.9.826.1.12.15.1.20

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:powerUsage managed object property

cfprComputeExtBoardPresence

1.3.6.1.4.1.9.9.826.1.12.15.1.21

CfprEquipmentPresence0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:presence managed object property

cfprComputeExtBoardRevision

1.3.6.1.4.1.9.9.826.1.12.15.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:revision managed object property

cfprComputeExtBoardSerial

1.3.6.1.4.1.9.9.826.1.12.15.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:serial managed object property

cfprComputeExtBoardSlotId

1.3.6.1.4.1.9.9.826.1.12.15.1.24

Gauge32

Cisco Firepower compute:ExtBoard:slotId managed object property

cfprComputeExtBoardThermal

1.3.6.1.4.1.9.9.826.1.12.15.1.25

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:thermal managed object property

cfprComputeExtBoardVendor

1.3.6.1.4.1.9.9.826.1.12.15.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ExtBoard:vendor managed object property

cfprComputeExtBoardVoltage

1.3.6.1.4.1.9.9.826.1.12.15.1.27

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:ExtBoard:voltage managed object property

cfprComputeFwSyncAckTable

1.3.6.1.4.1.9.9.826.1.12.16

Index: cfprComputeFwSyncAckInstanceId

Cisco Firepower compute:FwSyncAck managed object table

cfprComputeFwSyncAckInstanceId

1.3.6.1.4.1.9.9.826.1.12.16.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeFwSyncAckDn

1.3.6.1.4.1.9.9.826.1.12.16.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:FwSyncAck:dn managed object property

cfprComputeFwSyncAckRn

1.3.6.1.4.1.9.9.826.1.12.16.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:rn managed object property

cfprComputeFwSyncAckAcked

1.3.6.1.4.1.9.9.826.1.12.16.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:FwSyncAck:acked managed object property

cfprComputeFwSyncAckAckedBy

1.3.6.1.4.1.9.9.826.1.12.16.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:ackedBy managed object property

cfprComputeFwSyncAckAdminState

1.3.6.1.4.1.9.9.826.1.12.16.1.6

CfprTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower compute:FwSyncAck:adminState managed object property

cfprComputeFwSyncAckAutoDelete

1.3.6.1.4.1.9.9.826.1.12.16.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:FwSyncAck:autoDelete managed object property

cfprComputeFwSyncAckChangeBy

1.3.6.1.4.1.9.9.826.1.12.16.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:changeBy managed object property

cfprComputeFwSyncAckChangeDetails

1.3.6.1.4.1.9.9.826.1.12.16.1.9

CfprTrigAckChangeDetails · BITS

Cisco Firepower compute:FwSyncAck:changeDetails managed object property

cfprComputeFwSyncAckChanges

1.3.6.1.4.1.9.9.826.1.12.16.1.10

CfprTrigAckChanges · BITS

Cisco Firepower compute:FwSyncAck:changes managed object property

cfprComputeFwSyncAckDescr

1.3.6.1.4.1.9.9.826.1.12.16.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:descr managed object property

cfprComputeFwSyncAckDisr

1.3.6.1.4.1.9.9.826.1.12.16.1.12

CfprTrigAckDisr · BITS

Cisco Firepower compute:FwSyncAck:disr managed object property

cfprComputeFwSyncAckIgnoreCap

1.3.6.1.4.1.9.9.826.1.12.16.1.13

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:FwSyncAck:ignoreCap managed object property

cfprComputeFwSyncAckIntId

1.3.6.1.4.1.9.9.826.1.12.16.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:intId managed object property

cfprComputeFwSyncAckModified

1.3.6.1.4.1.9.9.826.1.12.16.1.15

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:FwSyncAck:modified managed object property

cfprComputeFwSyncAckName

1.3.6.1.4.1.9.9.826.1.12.16.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:name managed object property

cfprComputeFwSyncAckOperScheduler

1.3.6.1.4.1.9.9.826.1.12.16.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:operScheduler managed object property

cfprComputeFwSyncAckOperState

1.3.6.1.4.1.9.9.826.1.12.16.1.18

CfprTrigAckOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower compute:FwSyncAck:operState managed object property

cfprComputeFwSyncAckPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.16.1.19

Gauge32

Cisco Firepower compute:FwSyncAck:policyLevel managed object property

cfprComputeFwSyncAckPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.16.1.20

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:FwSyncAck:policyOwner managed object property

cfprComputeFwSyncAckPrevOperState

1.3.6.1.4.1.9.9.826.1.12.16.1.21

CfprTrigAckPrevOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower compute:FwSyncAck:prevOperState managed object property

cfprComputeFwSyncAckScheduler

1.3.6.1.4.1.9.9.826.1.12.16.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:FwSyncAck:scheduler managed object property

cfprComputeHealthLedSensorAlarmTable

1.3.6.1.4.1.9.9.826.1.12.17

Index: cfprComputeHealthLedSensorAlarmInstanceId

Cisco Firepower compute:HealthLedSensorAlarm managed object table

cfprComputeHealthLedSensorAlarmInstanceId

1.3.6.1.4.1.9.9.826.1.12.17.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeHealthLedSensorAlarmDn

1.3.6.1.4.1.9.9.826.1.12.17.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:HealthLedSensorAlarm:dn managed object property

cfprComputeHealthLedSensorAlarmRn

1.3.6.1.4.1.9.9.826.1.12.17.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:HealthLedSensorAlarm:rn managed object property

cfprComputeHealthLedSensorAlarmAlarmDesc

1.3.6.1.4.1.9.9.826.1.12.17.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:HealthLedSensorAlarm:alarmDesc managed object property

cfprComputeHealthLedSensorAlarmAlarmSeverity

1.3.6.1.4.1.9.9.826.1.12.17.1.5

CfprComputeAlarmSeverity1 = minor2 = severe · Integer32

Cisco Firepower compute:HealthLedSensorAlarm:alarmSeverity managed object property

cfprComputeHealthLedSensorAlarmSensorId

1.3.6.1.4.1.9.9.826.1.12.17.1.6

Gauge32

Cisco Firepower compute:HealthLedSensorAlarm:sensorId managed object property

cfprComputeHealthLedSensorAlarmSensorName

1.3.6.1.4.1.9.9.826.1.12.17.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:HealthLedSensorAlarm:sensorName managed object property

cfprComputeIOHubTable

1.3.6.1.4.1.9.9.826.1.12.18

Index: cfprComputeIOHubInstanceId

Cisco Firepower compute:IOHub managed object table

cfprComputeIOHubInstanceId

1.3.6.1.4.1.9.9.826.1.12.18.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeIOHubDn

1.3.6.1.4.1.9.9.826.1.12.18.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:IOHub:dn managed object property

cfprComputeIOHubRn

1.3.6.1.4.1.9.9.826.1.12.18.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:rn managed object property

cfprComputeIOHubId

1.3.6.1.4.1.9.9.826.1.12.18.1.4

Gauge32

Cisco Firepower compute:IOHub:id managed object property

cfprComputeIOHubLocationDn

1.3.6.1.4.1.9.9.826.1.12.18.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:locationDn managed object property

cfprComputeIOHubModel

1.3.6.1.4.1.9.9.826.1.12.18.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:model managed object property

cfprComputeIOHubOperQualifierReason

1.3.6.1.4.1.9.9.826.1.12.18.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:operQualifierReason managed object property

cfprComputeIOHubOperState

1.3.6.1.4.1.9.9.826.1.12.18.1.8

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:IOHub:operState managed object property

cfprComputeIOHubOperability

1.3.6.1.4.1.9.9.826.1.12.18.1.9

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:IOHub:operability managed object property

cfprComputeIOHubPerf

1.3.6.1.4.1.9.9.826.1.12.18.1.10

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:IOHub:perf managed object property

cfprComputeIOHubPower

1.3.6.1.4.1.9.9.826.1.12.18.1.11

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:IOHub:power managed object property

cfprComputeIOHubPresence

1.3.6.1.4.1.9.9.826.1.12.18.1.12

CfprEquipmentPresence0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized100 = notSupported · Integer32

Cisco Firepower compute:IOHub:presence managed object property

cfprComputeIOHubRevision

1.3.6.1.4.1.9.9.826.1.12.18.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:revision managed object property

cfprComputeIOHubSerial

1.3.6.1.4.1.9.9.826.1.12.18.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:serial managed object property

cfprComputeIOHubThermal

1.3.6.1.4.1.9.9.826.1.12.18.1.15

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:IOHub:thermal managed object property

cfprComputeIOHubVendor

1.3.6.1.4.1.9.9.826.1.12.18.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHub:vendor managed object property

cfprComputeIOHubVoltage

1.3.6.1.4.1.9.9.826.1.12.18.1.17

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:IOHub:voltage managed object property

cfprComputeIOHubEnvStatsTable

1.3.6.1.4.1.9.9.826.1.12.19

Index: cfprComputeIOHubEnvStatsInstanceId

Cisco Firepower compute:IOHubEnvStats managed object table

cfprComputeIOHubEnvStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.19.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeIOHubEnvStatsDn

1.3.6.1.4.1.9.9.826.1.12.19.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:IOHubEnvStats:dn managed object property

cfprComputeIOHubEnvStatsRn

1.3.6.1.4.1.9.9.826.1.12.19.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHubEnvStats:rn managed object property

cfprComputeIOHubEnvStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.19.1.4

Gauge32

Cisco Firepower compute:IOHubEnvStats:intervals managed object property

cfprComputeIOHubEnvStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.19.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:IOHubEnvStats:suspect managed object property

cfprComputeIOHubEnvStatsTemperature

1.3.6.1.4.1.9.9.826.1.12.19.1.6

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStats:temperature managed object property

cfprComputeIOHubEnvStatsTemperatureAvg

1.3.6.1.4.1.9.9.826.1.12.19.1.7

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStats:temperatureAvg managed object property

cfprComputeIOHubEnvStatsTemperatureMax

1.3.6.1.4.1.9.9.826.1.12.19.1.8

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStats:temperatureMax managed object property

cfprComputeIOHubEnvStatsTemperatureMin

1.3.6.1.4.1.9.9.826.1.12.19.1.9

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStats:temperatureMin managed object property

cfprComputeIOHubEnvStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.19.1.10

CfprComputeIOHubEnvStatsThresholded · BITS

Cisco Firepower compute:IOHubEnvStats:thresholded managed object property

cfprComputeIOHubEnvStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.19.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:IOHubEnvStats:timeCollected managed object property

cfprComputeIOHubEnvStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.19.1.12

Gauge32

Cisco Firepower compute:IOHubEnvStats:update managed object property

cfprComputeIOHubEnvStatsHistTable

1.3.6.1.4.1.9.9.826.1.12.20

Index: cfprComputeIOHubEnvStatsHistInstanceId

Cisco Firepower compute:IOHubEnvStatsHist managed object table

cfprComputeIOHubEnvStatsHistInstanceId

1.3.6.1.4.1.9.9.826.1.12.20.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeIOHubEnvStatsHistDn

1.3.6.1.4.1.9.9.826.1.12.20.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:IOHubEnvStatsHist:dn managed object property

cfprComputeIOHubEnvStatsHistRn

1.3.6.1.4.1.9.9.826.1.12.20.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:IOHubEnvStatsHist:rn managed object property

cfprComputeIOHubEnvStatsHistId

1.3.6.1.4.1.9.9.826.1.12.20.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:IOHubEnvStatsHist:id managed object property

cfprComputeIOHubEnvStatsHistMostRecent

1.3.6.1.4.1.9.9.826.1.12.20.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:IOHubEnvStatsHist:mostRecent managed object property

cfprComputeIOHubEnvStatsHistSuspect

1.3.6.1.4.1.9.9.826.1.12.20.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:IOHubEnvStatsHist:suspect managed object property

cfprComputeIOHubEnvStatsHistTemperature

1.3.6.1.4.1.9.9.826.1.12.20.1.7

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStatsHist:temperature managed object property

cfprComputeIOHubEnvStatsHistTemperatureAvg

1.3.6.1.4.1.9.9.826.1.12.20.1.8

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStatsHist:temperatureAvg managed object property

cfprComputeIOHubEnvStatsHistTemperatureMax

1.3.6.1.4.1.9.9.826.1.12.20.1.9

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStatsHist:temperatureMax managed object property

cfprComputeIOHubEnvStatsHistTemperatureMin

1.3.6.1.4.1.9.9.826.1.12.20.1.10

INTEGER · Integer32

Cisco Firepower compute:IOHubEnvStatsHist:temperatureMin managed object property

cfprComputeIOHubEnvStatsHistThresholded

1.3.6.1.4.1.9.9.826.1.12.20.1.11

CfprComputeIOHubEnvStatsHistThresholded · BITS

Cisco Firepower compute:IOHubEnvStatsHist:thresholded managed object property

cfprComputeIOHubEnvStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.1.12.20.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:IOHubEnvStatsHist:timeCollected managed object property

cfprComputeKvmMgmtPolicyTable

1.3.6.1.4.1.9.9.826.1.12.21

Index: cfprComputeKvmMgmtPolicyInstanceId

Cisco Firepower compute:KvmMgmtPolicy managed object table

cfprComputeKvmMgmtPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.21.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeKvmMgmtPolicyDn

1.3.6.1.4.1.9.9.826.1.12.21.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:KvmMgmtPolicy:dn managed object property

cfprComputeKvmMgmtPolicyRn

1.3.6.1.4.1.9.9.826.1.12.21.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:KvmMgmtPolicy:rn managed object property

cfprComputeKvmMgmtPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.21.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:KvmMgmtPolicy:descr managed object property

cfprComputeKvmMgmtPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.21.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:KvmMgmtPolicy:intId managed object property

cfprComputeKvmMgmtPolicyName

1.3.6.1.4.1.9.9.826.1.12.21.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:KvmMgmtPolicy:name managed object property

cfprComputeKvmMgmtPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.21.1.7

Gauge32

Cisco Firepower compute:KvmMgmtPolicy:policyLevel managed object property

cfprComputeKvmMgmtPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.21.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:KvmMgmtPolicy:policyOwner managed object property

cfprComputeKvmMgmtPolicyVmediaEncryption

1.3.6.1.4.1.9.9.826.1.12.21.1.9

CfprComputeKvmMgmtPolicyVmediaEncryption0 = disable1 = enable · Integer32

Cisco Firepower compute:KvmMgmtPolicy:vmediaEncryption managed object property

cfprComputeMbPowerStatsTable

1.3.6.1.4.1.9.9.826.1.12.22

Index: cfprComputeMbPowerStatsInstanceId

Cisco Firepower compute:MbPowerStats managed object table

cfprComputeMbPowerStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.22.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMbPowerStatsDn

1.3.6.1.4.1.9.9.826.1.12.22.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MbPowerStats:dn managed object property

cfprComputeMbPowerStatsRn

1.3.6.1.4.1.9.9.826.1.12.22.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MbPowerStats:rn managed object property

cfprComputeMbPowerStatsConsumedPower

1.3.6.1.4.1.9.9.826.1.12.22.1.4

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:consumedPower managed object property

cfprComputeMbPowerStatsConsumedPowerAvg

1.3.6.1.4.1.9.9.826.1.12.22.1.5

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:consumedPowerAvg managed object property

cfprComputeMbPowerStatsConsumedPowerMax

1.3.6.1.4.1.9.9.826.1.12.22.1.6

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:consumedPowerMax managed object property

cfprComputeMbPowerStatsConsumedPowerMin

1.3.6.1.4.1.9.9.826.1.12.22.1.7

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:consumedPowerMin managed object property

cfprComputeMbPowerStatsInputCurrent

1.3.6.1.4.1.9.9.826.1.12.22.1.8

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputCurrent managed object property

cfprComputeMbPowerStatsInputCurrentAvg

1.3.6.1.4.1.9.9.826.1.12.22.1.9

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputCurrentAvg managed object property

cfprComputeMbPowerStatsInputCurrentMax

1.3.6.1.4.1.9.9.826.1.12.22.1.10

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputCurrentMax managed object property

cfprComputeMbPowerStatsInputCurrentMin

1.3.6.1.4.1.9.9.826.1.12.22.1.11

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputCurrentMin managed object property

cfprComputeMbPowerStatsInputVoltage

1.3.6.1.4.1.9.9.826.1.12.22.1.12

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputVoltage managed object property

cfprComputeMbPowerStatsInputVoltageAvg

1.3.6.1.4.1.9.9.826.1.12.22.1.13

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputVoltageAvg managed object property

cfprComputeMbPowerStatsInputVoltageMax

1.3.6.1.4.1.9.9.826.1.12.22.1.14

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputVoltageMax managed object property

cfprComputeMbPowerStatsInputVoltageMin

1.3.6.1.4.1.9.9.826.1.12.22.1.15

INTEGER · Integer32

Cisco Firepower compute:MbPowerStats:inputVoltageMin managed object property

cfprComputeMbPowerStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.22.1.16

Gauge32

Cisco Firepower compute:MbPowerStats:intervals managed object property

cfprComputeMbPowerStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.22.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:MbPowerStats:suspect managed object property

cfprComputeMbPowerStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.22.1.18

CfprComputeMbPowerStatsThresholded · BITS

Cisco Firepower compute:MbPowerStats:thresholded managed object property

cfprComputeMbPowerStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.22.1.19

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:MbPowerStats:timeCollected managed object property

cfprComputeMbPowerStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.22.1.20

Gauge32

Cisco Firepower compute:MbPowerStats:update managed object property

cfprComputeMbPowerStatsHistTable

1.3.6.1.4.1.9.9.826.1.12.23

Index: cfprComputeMbPowerStatsHistInstanceId

Cisco Firepower compute:MbPowerStatsHist managed object table

cfprComputeMbPowerStatsHistInstanceId

1.3.6.1.4.1.9.9.826.1.12.23.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMbPowerStatsHistDn

1.3.6.1.4.1.9.9.826.1.12.23.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MbPowerStatsHist:dn managed object property

cfprComputeMbPowerStatsHistRn

1.3.6.1.4.1.9.9.826.1.12.23.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MbPowerStatsHist:rn managed object property

cfprComputeMbPowerStatsHistConsumedPower

1.3.6.1.4.1.9.9.826.1.12.23.1.4

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:consumedPower managed object property

cfprComputeMbPowerStatsHistConsumedPowerAvg

1.3.6.1.4.1.9.9.826.1.12.23.1.5

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:consumedPowerAvg managed object property

cfprComputeMbPowerStatsHistConsumedPowerMax

1.3.6.1.4.1.9.9.826.1.12.23.1.6

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:consumedPowerMax managed object property

cfprComputeMbPowerStatsHistConsumedPowerMin

1.3.6.1.4.1.9.9.826.1.12.23.1.7

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:consumedPowerMin managed object property

cfprComputeMbPowerStatsHistId

1.3.6.1.4.1.9.9.826.1.12.23.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:MbPowerStatsHist:id managed object property

cfprComputeMbPowerStatsHistInputCurrent

1.3.6.1.4.1.9.9.826.1.12.23.1.9

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputCurrent managed object property

cfprComputeMbPowerStatsHistInputCurrentAvg

1.3.6.1.4.1.9.9.826.1.12.23.1.10

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputCurrentAvg managed object property

cfprComputeMbPowerStatsHistInputCurrentMax

1.3.6.1.4.1.9.9.826.1.12.23.1.11

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputCurrentMax managed object property

cfprComputeMbPowerStatsHistInputCurrentMin

1.3.6.1.4.1.9.9.826.1.12.23.1.12

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputCurrentMin managed object property

cfprComputeMbPowerStatsHistInputVoltage

1.3.6.1.4.1.9.9.826.1.12.23.1.13

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputVoltage managed object property

cfprComputeMbPowerStatsHistInputVoltageAvg

1.3.6.1.4.1.9.9.826.1.12.23.1.14

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputVoltageAvg managed object property

cfprComputeMbPowerStatsHistInputVoltageMax

1.3.6.1.4.1.9.9.826.1.12.23.1.15

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputVoltageMax managed object property

cfprComputeMbPowerStatsHistInputVoltageMin

1.3.6.1.4.1.9.9.826.1.12.23.1.16

INTEGER · Integer32

Cisco Firepower compute:MbPowerStatsHist:inputVoltageMin managed object property

cfprComputeMbPowerStatsHistMostRecent

1.3.6.1.4.1.9.9.826.1.12.23.1.17

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:MbPowerStatsHist:mostRecent managed object property

cfprComputeMbPowerStatsHistSuspect

1.3.6.1.4.1.9.9.826.1.12.23.1.18

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:MbPowerStatsHist:suspect managed object property

cfprComputeMbPowerStatsHistThresholded

1.3.6.1.4.1.9.9.826.1.12.23.1.19

CfprComputeMbPowerStatsHistThresholded · BITS

Cisco Firepower compute:MbPowerStatsHist:thresholded managed object property

cfprComputeMbPowerStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.1.12.23.1.20

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:MbPowerStatsHist:timeCollected managed object property

cfprComputeMbTempStatsTable

1.3.6.1.4.1.9.9.826.1.12.24

Index: cfprComputeMbTempStatsInstanceId

Cisco Firepower compute:MbTempStats managed object table

cfprComputeMbTempStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.24.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMbTempStatsDn

1.3.6.1.4.1.9.9.826.1.12.24.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MbTempStats:dn managed object property

cfprComputeMbTempStatsRn

1.3.6.1.4.1.9.9.826.1.12.24.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MbTempStats:rn managed object property

cfprComputeMbTempStatsFmTempSenIo

1.3.6.1.4.1.9.9.826.1.12.24.1.4

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenIo managed object property

cfprComputeMbTempStatsFmTempSenIoAvg

1.3.6.1.4.1.9.9.826.1.12.24.1.5

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenIoAvg managed object property

cfprComputeMbTempStatsFmTempSenIoMax

1.3.6.1.4.1.9.9.826.1.12.24.1.6

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenIoMax managed object property

cfprComputeMbTempStatsFmTempSenIoMin

1.3.6.1.4.1.9.9.826.1.12.24.1.7

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenIoMin managed object property

cfprComputeMbTempStatsFmTempSenRear

1.3.6.1.4.1.9.9.826.1.12.24.1.8

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRear managed object property

cfprComputeMbTempStatsFmTempSenRearAvg

1.3.6.1.4.1.9.9.826.1.12.24.1.9

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearAvg managed object property

cfprComputeMbTempStatsFmTempSenRearL

1.3.6.1.4.1.9.9.826.1.12.24.1.10

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearL managed object property

cfprComputeMbTempStatsFmTempSenRearLAvg

1.3.6.1.4.1.9.9.826.1.12.24.1.11

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearLAvg managed object property

cfprComputeMbTempStatsFmTempSenRearLMax

1.3.6.1.4.1.9.9.826.1.12.24.1.12

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearLMax managed object property

cfprComputeMbTempStatsFmTempSenRearLMin

1.3.6.1.4.1.9.9.826.1.12.24.1.13

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearLMin managed object property

cfprComputeMbTempStatsFmTempSenRearMax

1.3.6.1.4.1.9.9.826.1.12.24.1.14

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearMax managed object property

cfprComputeMbTempStatsFmTempSenRearMin

1.3.6.1.4.1.9.9.826.1.12.24.1.15

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearMin managed object property

cfprComputeMbTempStatsFmTempSenRearR

1.3.6.1.4.1.9.9.826.1.12.24.1.16

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearR managed object property

cfprComputeMbTempStatsFmTempSenRearRAvg

1.3.6.1.4.1.9.9.826.1.12.24.1.17

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearRAvg managed object property

cfprComputeMbTempStatsFmTempSenRearRMax

1.3.6.1.4.1.9.9.826.1.12.24.1.18

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearRMax managed object property

cfprComputeMbTempStatsFmTempSenRearRMin

1.3.6.1.4.1.9.9.826.1.12.24.1.19

INTEGER · Integer32

Cisco Firepower compute:MbTempStats:fmTempSenRearRMin managed object property

cfprComputeMbTempStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.24.1.20

Gauge32

Cisco Firepower compute:MbTempStats:intervals managed object property

cfprComputeMbTempStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.24.1.21

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:MbTempStats:suspect managed object property

cfprComputeMbTempStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.24.1.22

CfprComputeMbTempStatsThresholded · BITS

Cisco Firepower compute:MbTempStats:thresholded managed object property

cfprComputeMbTempStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.24.1.23

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:MbTempStats:timeCollected managed object property

cfprComputeMbTempStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.24.1.24

Gauge32

Cisco Firepower compute:MbTempStats:update managed object property

cfprComputeMbTempStatsHistTable

1.3.6.1.4.1.9.9.826.1.12.25

Index: cfprComputeMbTempStatsHistInstanceId

Cisco Firepower compute:MbTempStatsHist managed object table

cfprComputeMbTempStatsHistInstanceId

1.3.6.1.4.1.9.9.826.1.12.25.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMbTempStatsHistDn

1.3.6.1.4.1.9.9.826.1.12.25.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MbTempStatsHist:dn managed object property

cfprComputeMbTempStatsHistRn

1.3.6.1.4.1.9.9.826.1.12.25.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MbTempStatsHist:rn managed object property

cfprComputeMbTempStatsHistFmTempSenIo

1.3.6.1.4.1.9.9.826.1.12.25.1.4

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenIo managed object property

cfprComputeMbTempStatsHistFmTempSenIoAvg

1.3.6.1.4.1.9.9.826.1.12.25.1.5

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenIoAvg managed object property

cfprComputeMbTempStatsHistFmTempSenIoMax

1.3.6.1.4.1.9.9.826.1.12.25.1.6

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenIoMax managed object property

cfprComputeMbTempStatsHistFmTempSenIoMin

1.3.6.1.4.1.9.9.826.1.12.25.1.7

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenIoMin managed object property

cfprComputeMbTempStatsHistFmTempSenRear

1.3.6.1.4.1.9.9.826.1.12.25.1.8

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRear managed object property

cfprComputeMbTempStatsHistFmTempSenRearAvg

1.3.6.1.4.1.9.9.826.1.12.25.1.9

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearAvg managed object property

cfprComputeMbTempStatsHistFmTempSenRearL

1.3.6.1.4.1.9.9.826.1.12.25.1.10

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearL managed object property

cfprComputeMbTempStatsHistFmTempSenRearLAvg

1.3.6.1.4.1.9.9.826.1.12.25.1.11

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearLAvg managed object property

cfprComputeMbTempStatsHistFmTempSenRearLMax

1.3.6.1.4.1.9.9.826.1.12.25.1.12

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearLMax managed object property

cfprComputeMbTempStatsHistFmTempSenRearLMin

1.3.6.1.4.1.9.9.826.1.12.25.1.13

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearLMin managed object property

cfprComputeMbTempStatsHistFmTempSenRearMax

1.3.6.1.4.1.9.9.826.1.12.25.1.14

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearMax managed object property

cfprComputeMbTempStatsHistFmTempSenRearMin

1.3.6.1.4.1.9.9.826.1.12.25.1.15

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearMin managed object property

cfprComputeMbTempStatsHistFmTempSenRearR

1.3.6.1.4.1.9.9.826.1.12.25.1.16

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearR managed object property

cfprComputeMbTempStatsHistFmTempSenRearRAvg

1.3.6.1.4.1.9.9.826.1.12.25.1.17

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearRAvg managed object property

cfprComputeMbTempStatsHistFmTempSenRearRMax

1.3.6.1.4.1.9.9.826.1.12.25.1.18

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearRMax managed object property

cfprComputeMbTempStatsHistFmTempSenRearRMin

1.3.6.1.4.1.9.9.826.1.12.25.1.19

INTEGER · Integer32

Cisco Firepower compute:MbTempStatsHist:fmTempSenRearRMin managed object property

cfprComputeMbTempStatsHistId

1.3.6.1.4.1.9.9.826.1.12.25.1.20

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:MbTempStatsHist:id managed object property

cfprComputeMbTempStatsHistMostRecent

1.3.6.1.4.1.9.9.826.1.12.25.1.21

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:MbTempStatsHist:mostRecent managed object property

cfprComputeMbTempStatsHistSuspect

1.3.6.1.4.1.9.9.826.1.12.25.1.22

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:MbTempStatsHist:suspect managed object property

cfprComputeMbTempStatsHistThresholded

1.3.6.1.4.1.9.9.826.1.12.25.1.23

CfprComputeMbTempStatsHistThresholded · BITS

Cisco Firepower compute:MbTempStatsHist:thresholded managed object property

cfprComputeMbTempStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.1.12.25.1.24

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:MbTempStatsHist:timeCollected managed object property

cfprComputeMemoryConfigPolicyTable

1.3.6.1.4.1.9.9.826.1.12.26

Index: cfprComputeMemoryConfigPolicyInstanceId

Cisco Firepower compute:MemoryConfigPolicy managed object table

cfprComputeMemoryConfigPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.26.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMemoryConfigPolicyDn

1.3.6.1.4.1.9.9.826.1.12.26.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MemoryConfigPolicy:dn managed object property

cfprComputeMemoryConfigPolicyRn

1.3.6.1.4.1.9.9.826.1.12.26.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryConfigPolicy:rn managed object property

cfprComputeMemoryConfigPolicyBlackListing

1.3.6.1.4.1.9.9.826.1.12.26.1.4

CfprComputeBlackListing0 = disabled1 = enabled · Integer32

Cisco Firepower compute:MemoryConfigPolicy:blackListing managed object property

cfprComputeMemoryConfigPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.26.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryConfigPolicy:descr managed object property

cfprComputeMemoryConfigPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.26.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryConfigPolicy:intId managed object property

cfprComputeMemoryConfigPolicyName

1.3.6.1.4.1.9.9.826.1.12.26.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryConfigPolicy:name managed object property

cfprComputeMemoryConfigPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.26.1.8

Gauge32

Cisco Firepower compute:MemoryConfigPolicy:policyLevel managed object property

cfprComputeMemoryConfigPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.26.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:MemoryConfigPolicy:policyOwner managed object property

cfprComputeMemoryConfigurationTable

1.3.6.1.4.1.9.9.826.1.12.27

Index: cfprComputeMemoryConfigurationInstanceId

Cisco Firepower compute:MemoryConfiguration managed object table

cfprComputeMemoryConfigurationInstanceId

1.3.6.1.4.1.9.9.826.1.12.27.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMemoryConfigurationDn

1.3.6.1.4.1.9.9.826.1.12.27.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MemoryConfiguration:dn managed object property

cfprComputeMemoryConfigurationRn

1.3.6.1.4.1.9.9.826.1.12.27.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryConfiguration:rn managed object property

cfprComputeMemoryConfigurationAdminMemoryState

1.3.6.1.4.1.9.9.826.1.12.27.1.4

CfprComputeAdminMemoryState1 = policy2 = resetMemoryErrors3 = resetInProgress · Integer32

Cisco Firepower compute:MemoryConfiguration:adminMemoryState managed object property

cfprComputeMemoryConfigurationBlackListing

1.3.6.1.4.1.9.9.826.1.12.27.1.5

CfprComputeBlackListing0 = disabled1 = enabled · Integer32

Cisco Firepower compute:MemoryConfiguration:blackListing managed object property

cfprComputeMemoryUnitConstraintDefTable

1.3.6.1.4.1.9.9.826.1.12.28

Index: cfprComputeMemoryUnitConstraintDefInstanceId

Cisco Firepower compute:MemoryUnitConstraintDef managed object table

cfprComputeMemoryUnitConstraintDefInstanceId

1.3.6.1.4.1.9.9.826.1.12.28.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeMemoryUnitConstraintDefDn

1.3.6.1.4.1.9.9.826.1.12.28.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:MemoryUnitConstraintDef:dn managed object property

cfprComputeMemoryUnitConstraintDefRn

1.3.6.1.4.1.9.9.826.1.12.28.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryUnitConstraintDef:rn managed object property

cfprComputeMemoryUnitConstraintDefDescr

1.3.6.1.4.1.9.9.826.1.12.28.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryUnitConstraintDef:descr managed object property

cfprComputeMemoryUnitConstraintDefIntId

1.3.6.1.4.1.9.9.826.1.12.28.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryUnitConstraintDef:intId managed object property

cfprComputeMemoryUnitConstraintDefName

1.3.6.1.4.1.9.9.826.1.12.28.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryUnitConstraintDef:name managed object property

cfprComputeMemoryUnitConstraintDefPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.28.1.7

Gauge32

Cisco Firepower compute:MemoryUnitConstraintDef:policyLevel managed object property

cfprComputeMemoryUnitConstraintDefPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.28.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:MemoryUnitConstraintDef:policyOwner managed object property

cfprComputeMemoryUnitConstraintDefRevisionModifier

1.3.6.1.4.1.9.9.826.1.12.28.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:MemoryUnitConstraintDef:revisionModifier managed object property

cfprComputeMemoryUnitConstraintDefType

1.3.6.1.4.1.9.9.826.1.12.28.1.10

CfprComputeMemoryUnitConstraintType0 = unknown1 = kit · Integer32

Cisco Firepower compute:MemoryUnitConstraintDef:type managed object property

cfprComputePCIeFatalCompletionStatsTable

1.3.6.1.4.1.9.9.826.1.12.29

Index: cfprComputePCIeFatalCompletionStatsInstanceId

Cisco Firepower compute:PCIeFatalCompletionStats managed object table

cfprComputePCIeFatalCompletionStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.29.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePCIeFatalCompletionStatsDn

1.3.6.1.4.1.9.9.826.1.12.29.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PCIeFatalCompletionStats:dn managed object property

cfprComputePCIeFatalCompletionStatsRn

1.3.6.1.4.1.9.9.826.1.12.29.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PCIeFatalCompletionStats:rn managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors

1.3.6.1.4.1.9.9.826.1.12.29.1.4

Counter32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors15Min

1.3.6.1.4.1.9.9.826.1.12.29.1.5

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors15Min managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.29.1.6

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors15Min H managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors1Day

1.3.6.1.4.1.9.9.826.1.12.29.1.7

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Day managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.29.1.8

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1DayH managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.29.1.9

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Hour managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.29.1.10

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Hour H managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors1Week

1.3.6.1.4.1.9.9.826.1.12.29.1.11

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Week managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.29.1.12

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors1Week H managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.29.1.13

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors2Week s managed object property

cfprComputePCIeFatalCompletionStatsAbortErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.29.1.14

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:AbortErrors2Week sH managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors

1.3.6.1.4.1.9.9.826.1.12.29.1.15

Counter32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors15Min

1.3.6.1.4.1.9.9.826.1.12.29.1.16

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors15M in managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.29.1.17

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors15M inH managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors1Day

1.3.6.1.4.1.9.9.826.1.12.29.1.18

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Da y managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.29.1.19

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Da yH managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.29.1.20

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Ho ur managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.29.1.21

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1Ho urH managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors1Week

1.3.6.1.4.1.9.9.826.1.12.29.1.22

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1We ek managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.29.1.23

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors1We ekH managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.29.1.24

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors2We eks managed object property

cfprComputePCIeFatalCompletionStatsTimeoutErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.29.1.25

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:TimeoutErrors2We eksH managed object property

cfprComputePCIeFatalCompletionStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.29.1.26

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:intervals managed object property

cfprComputePCIeFatalCompletionStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.29.1.27

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:PCIeFatalCompletionStats:suspect managed object property

cfprComputePCIeFatalCompletionStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.29.1.28

CfprComputePCIeFatalCompletionStatsThresholded · BITS

Cisco Firepower compute:PCIeFatalCompletionStats:thresholded managed object property

cfprComputePCIeFatalCompletionStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.29.1.29

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:PCIeFatalCompletionStats:timeCollected managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors

1.3.6.1.4.1.9.9.826.1.12.29.1.30

Counter32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors15Min

1.3.6.1.4.1.9.9.826.1.12.29.1.31

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 15Min managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.29.1.32

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 15MinH managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors1Day

1.3.6.1.4.1.9.9.826.1.12.29.1.33

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 1Day managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.29.1.34

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 1DayH managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.29.1.35

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 1Hour managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.29.1.36

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 1HourH managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors1Week

1.3.6.1.4.1.9.9.826.1.12.29.1.37

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 1Week managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.29.1.38

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 1WeekH managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.29.1.39

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 2Weeks managed object property

cfprComputePCIeFatalCompletionStatsUnexpectedErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.29.1.40

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:unexpectedErrors 2WeeksH managed object property

cfprComputePCIeFatalCompletionStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.29.1.41

Gauge32

Cisco Firepower compute:PCIeFatalCompletionStats:update managed object property

cfprComputePCIeFatalProtocolStatsTable

1.3.6.1.4.1.9.9.826.1.12.30

Index: cfprComputePCIeFatalProtocolStatsInstanceId

Cisco Firepower compute:PCIeFatalProtocolStats managed object table

cfprComputePCIeFatalProtocolStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.30.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePCIeFatalProtocolStatsDn

1.3.6.1.4.1.9.9.826.1.12.30.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PCIeFatalProtocolStats:dn managed object property

cfprComputePCIeFatalProtocolStatsRn

1.3.6.1.4.1.9.9.826.1.12.30.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PCIeFatalProtocolStats:rn managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors

1.3.6.1.4.1.9.9.826.1.12.30.1.4

Counter32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors15Min

1.3.6.1.4.1.9.9.826.1.12.30.1.5

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors15Min managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.30.1.6

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors15MinH managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors1Day

1.3.6.1.4.1.9.9.826.1.12.30.1.7

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1Day managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.30.1.8

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1DayH managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.30.1.9

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1Hour managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.30.1.10

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1HourH managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors1Week

1.3.6.1.4.1.9.9.826.1.12.30.1.11

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1Week managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.30.1.12

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors1WeekH managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.30.1.13

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors2Weeks managed object property

cfprComputePCIeFatalProtocolStatsDllpErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.30.1.14

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:dllpErrors2WeeksH managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors

1.3.6.1.4.1.9.9.826.1.12.30.1.15

Counter32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors15Min

1.3.6.1.4.1.9.9.826.1.12.30.1.16

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 5Min managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.30.1.17

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 5MinH managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors1Day

1.3.6.1.4.1.9.9.826.1.12.30.1.18

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 Day managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.30.1.19

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 DayH managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.30.1.20

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 Hour managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.30.1.21

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 HourH managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors1Week

1.3.6.1.4.1.9.9.826.1.12.30.1.22

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 Week managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.30.1.23

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors1 WeekH managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.30.1.24

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors2 Weeks managed object property

cfprComputePCIeFatalProtocolStatsFlowControlErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.30.1.25

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:flowControlErrors2 WeeksH managed object property

cfprComputePCIeFatalProtocolStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.30.1.26

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:intervals managed object property

cfprComputePCIeFatalProtocolStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.30.1.27

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:PCIeFatalProtocolStats:suspect managed object property

cfprComputePCIeFatalProtocolStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.30.1.28

CfprComputePCIeFatalProtocolStatsThresholded · BITS

Cisco Firepower compute:PCIeFatalProtocolStats:thresholded managed object property

cfprComputePCIeFatalProtocolStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.30.1.29

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:PCIeFatalProtocolStats:timeCollected managed object property

cfprComputePCIeFatalProtocolStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.30.1.30

Gauge32

Cisco Firepower compute:PCIeFatalProtocolStats:update managed object property

cfprComputePCIeFatalReceiveStatsTable

1.3.6.1.4.1.9.9.826.1.12.31

Index: cfprComputePCIeFatalReceiveStatsInstanceId

Cisco Firepower compute:PCIeFatalReceiveStats managed object table

cfprComputePCIeFatalReceiveStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.31.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePCIeFatalReceiveStatsDn

1.3.6.1.4.1.9.9.826.1.12.31.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PCIeFatalReceiveStats:dn managed object property

cfprComputePCIeFatalReceiveStatsRn

1.3.6.1.4.1.9.9.826.1.12.31.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PCIeFatalReceiveStats:rn managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors

1.3.6.1.4.1.9.9.826.1.12.31.1.4

Counter32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors15Min

1.3.6.1.4.1.9.9.826.1.12.31.1.5

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s15Min managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.31.1.6

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s15MinH managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors1Day

1.3.6.1.4.1.9.9.826.1.12.31.1.7

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s1Day managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.31.1.8

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s1DayH managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.31.1.9

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s1Hour managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.31.1.10

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s1HourH managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors1Week

1.3.6.1.4.1.9.9.826.1.12.31.1.11

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s1Week managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.31.1.12

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s1WeekH managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.31.1.13

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s2Weeks managed object property

cfprComputePCIeFatalReceiveStatsBufferOverflowErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.31.1.14

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:bufferOverflowError s2WeeksH managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors

1.3.6.1.4.1.9.9.826.1.12.31.1.15

Counter32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors15Min

1.3.6.1.4.1.9.9.826.1.12.31.1.16

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors15Min managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.31.1.17

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors15Min H managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors1Day

1.3.6.1.4.1.9.9.826.1.12.31.1.18

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Day managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.31.1.19

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1DayH managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.31.1.20

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Hour managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.31.1.21

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Hour H managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors1Week

1.3.6.1.4.1.9.9.826.1.12.31.1.22

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Week managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.31.1.23

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors1Week H managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.31.1.24

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors2Week s managed object property

cfprComputePCIeFatalReceiveStatsErrFatalErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.31.1.25

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errFatalErrors2Week sH managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors

1.3.6.1.4.1.9.9.826.1.12.31.1.26

Counter32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors15Min

1.3.6.1.4.1.9.9.826.1.12.31.1.27

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors15 Min managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.31.1.28

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors15 MinH managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors1Day

1.3.6.1.4.1.9.9.826.1.12.31.1.29

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1D ay managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.31.1.30

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1D ayH managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.31.1.31

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1H our managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.31.1.32

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1H ourH managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors1Week

1.3.6.1.4.1.9.9.826.1.12.31.1.33

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1W eek managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.31.1.34

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors1W eekH managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.31.1.35

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors2W eeks managed object property

cfprComputePCIeFatalReceiveStatsErrNonFatalErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.31.1.36

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:errNonFatalErrors2W eeksH managed object property

cfprComputePCIeFatalReceiveStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.31.1.37

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:intervals managed object property

cfprComputePCIeFatalReceiveStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.31.1.38

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:PCIeFatalReceiveStats:suspect managed object property

cfprComputePCIeFatalReceiveStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.31.1.39

CfprComputePCIeFatalReceiveStatsThresholded · BITS

Cisco Firepower compute:PCIeFatalReceiveStats:thresholded managed object property

cfprComputePCIeFatalReceiveStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.31.1.40

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:PCIeFatalReceiveStats:timeCollected managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors

1.3.6.1.4.1.9.9.826.1.12.31.1.41

Counter32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors15Min

1.3.6.1.4.1.9.9.826.1.12.31.1.42

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors15Min managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.31.1.43

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors15MinH managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Day

1.3.6.1.4.1.9.9.826.1.12.31.1.44

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors1Day managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.31.1.45

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors1DayH managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.31.1.46

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors1Hour managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.31.1.47

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors1HourH managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors1Week

1.3.6.1.4.1.9.9.826.1.12.31.1.48

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors1Week managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.31.1.49

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors1WeekH managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.31.1.50

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors2Weeks managed object property

cfprComputePCIeFatalReceiveStatsUnsupportedRequestErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.31.1.51

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:unsupportedRequestE rrors2WeeksH managed object property

cfprComputePCIeFatalReceiveStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.31.1.52

Gauge32

Cisco Firepower compute:PCIeFatalReceiveStats:update managed object property

cfprComputePCIeFatalStatsTable

1.3.6.1.4.1.9.9.826.1.12.32

Index: cfprComputePCIeFatalStatsInstanceId

Cisco Firepower compute:PCIeFatalStats managed object table

cfprComputePCIeFatalStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.32.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePCIeFatalStatsDn

1.3.6.1.4.1.9.9.826.1.12.32.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PCIeFatalStats:dn managed object property

cfprComputePCIeFatalStatsRn

1.3.6.1.4.1.9.9.826.1.12.32.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PCIeFatalStats:rn managed object property

cfprComputePCIeFatalStatsAcsViolationErrors

1.3.6.1.4.1.9.9.826.1.12.32.1.4

Counter32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors managed object property

cfprComputePCIeFatalStatsAcsViolationErrors15Min

1.3.6.1.4.1.9.9.826.1.12.32.1.5

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors15Min managed object property

cfprComputePCIeFatalStatsAcsViolationErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.32.1.6

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors15MinH managed object property

cfprComputePCIeFatalStatsAcsViolationErrors1Day

1.3.6.1.4.1.9.9.826.1.12.32.1.7

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1Day managed object property

cfprComputePCIeFatalStatsAcsViolationErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.32.1.8

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1DayH managed object property

cfprComputePCIeFatalStatsAcsViolationErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.32.1.9

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1Hour managed object property

cfprComputePCIeFatalStatsAcsViolationErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.32.1.10

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1HourH managed object property

cfprComputePCIeFatalStatsAcsViolationErrors1Week

1.3.6.1.4.1.9.9.826.1.12.32.1.11

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1Week managed object property

cfprComputePCIeFatalStatsAcsViolationErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.32.1.12

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors1WeekH managed object property

cfprComputePCIeFatalStatsAcsViolationErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.32.1.13

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors2Weeks managed object property

cfprComputePCIeFatalStatsAcsViolationErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.32.1.14

Gauge32

Cisco Firepower compute:PCIeFatalStats:acsViolationErrors2WeeksH managed object property

cfprComputePCIeFatalStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.32.1.15

Gauge32

Cisco Firepower compute:PCIeFatalStats:intervals managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors

1.3.6.1.4.1.9.9.826.1.12.32.1.16

Counter32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors15Min

1.3.6.1.4.1.9.9.826.1.12.32.1.17

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors15Min managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.32.1.18

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors15MinH managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors1Day

1.3.6.1.4.1.9.9.826.1.12.32.1.19

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1Day managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.32.1.20

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1DayH managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.32.1.21

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1Hour managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.32.1.22

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1HourH managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors1Week

1.3.6.1.4.1.9.9.826.1.12.32.1.23

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1Week managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.32.1.24

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors1WeekH managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.32.1.25

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors2Weeks managed object property

cfprComputePCIeFatalStatsMalformedTLPErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.32.1.26

Gauge32

Cisco Firepower compute:PCIeFatalStats:malformedTLPErrors2WeeksH managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors

1.3.6.1.4.1.9.9.826.1.12.32.1.27

Counter32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors15Min

1.3.6.1.4.1.9.9.826.1.12.32.1.28

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors15Min managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.32.1.29

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors15MinH managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors1Day

1.3.6.1.4.1.9.9.826.1.12.32.1.30

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1Day managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.32.1.31

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1DayH managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.32.1.32

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1Hour managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.32.1.33

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1HourH managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors1Week

1.3.6.1.4.1.9.9.826.1.12.32.1.34

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1Week managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.32.1.35

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors1WeekH managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.32.1.36

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors2Weeks managed object property

cfprComputePCIeFatalStatsPoisonedTLPErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.32.1.37

Gauge32

Cisco Firepower compute:PCIeFatalStats:poisonedTLPErrors2WeeksH managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors

1.3.6.1.4.1.9.9.826.1.12.32.1.38

Counter32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors15Min

1.3.6.1.4.1.9.9.826.1.12.32.1.39

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors15Mi n managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors15MinH

1.3.6.1.4.1.9.9.826.1.12.32.1.40

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors15Mi nH managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors1Day

1.3.6.1.4.1.9.9.826.1.12.32.1.41

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Day managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors1DayH

1.3.6.1.4.1.9.9.826.1.12.32.1.42

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Day H managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors1Hour

1.3.6.1.4.1.9.9.826.1.12.32.1.43

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Hou r managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors1HourH

1.3.6.1.4.1.9.9.826.1.12.32.1.44

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Hou rH managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors1Week

1.3.6.1.4.1.9.9.826.1.12.32.1.45

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Wee k managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors1WeekH

1.3.6.1.4.1.9.9.826.1.12.32.1.46

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors1Wee kH managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors2Weeks

1.3.6.1.4.1.9.9.826.1.12.32.1.47

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors2Wee ks managed object property

cfprComputePCIeFatalStatsSurpriseLinkDownErrors2WeeksH

1.3.6.1.4.1.9.9.826.1.12.32.1.48

Gauge32

Cisco Firepower compute:PCIeFatalStats:surpriseLinkDownErrors2Wee ksH managed object property

cfprComputePCIeFatalStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.32.1.49

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:PCIeFatalStats:suspect managed object property

cfprComputePCIeFatalStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.32.1.50

CfprComputePCIeFatalStatsThresholded · BITS

Cisco Firepower compute:PCIeFatalStats:thresholded managed object property

cfprComputePCIeFatalStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.32.1.51

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:PCIeFatalStats:timeCollected managed object property

cfprComputePCIeFatalStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.32.1.52

Gauge32

Cisco Firepower compute:PCIeFatalStats:update managed object property

cfprComputePciCapTable

1.3.6.1.4.1.9.9.826.1.12.33

Index: cfprComputePciCapInstanceId

Cisco Firepower compute:PciCap managed object table

cfprComputePciCapInstanceId

1.3.6.1.4.1.9.9.826.1.12.33.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePciCapDn

1.3.6.1.4.1.9.9.826.1.12.33.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PciCap:dn managed object property

cfprComputePciCapRn

1.3.6.1.4.1.9.9.826.1.12.33.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PciCap:rn managed object property

cfprComputePciCapMaxBusIdPerSlot

1.3.6.1.4.1.9.9.826.1.12.33.1.4

Gauge32

Cisco Firepower compute:PciCap:maxBusIdPerSlot managed object property

cfprComputePciCapNumOfPhysSlots

1.3.6.1.4.1.9.9.826.1.12.33.1.5

Gauge32

Cisco Firepower compute:PciCap:numOfPhysSlots managed object property

cfprComputePciCapOrder

1.3.6.1.4.1.9.9.826.1.12.33.1.6

CfprComputePciCapOrder0 = ascending1 = descending2 = ascendingDual3 = ascendingSeq4 = ascendingExtended · Integer32

Cisco Firepower compute:PciCap:order managed object property

cfprComputePciCapStartsWith

1.3.6.1.4.1.9.9.826.1.12.33.1.7

Gauge32

Cisco Firepower compute:PciCap:startsWith managed object property

cfprComputePciSlotScanDefTable

1.3.6.1.4.1.9.9.826.1.12.34

Index: cfprComputePciSlotScanDefInstanceId

Cisco Firepower compute:PciSlotScanDef managed object table

cfprComputePciSlotScanDefInstanceId

1.3.6.1.4.1.9.9.826.1.12.34.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePciSlotScanDefDn

1.3.6.1.4.1.9.9.826.1.12.34.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PciSlotScanDef:dn managed object property

cfprComputePciSlotScanDefRn

1.3.6.1.4.1.9.9.826.1.12.34.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PciSlotScanDef:rn managed object property

cfprComputePciSlotScanDefDescr

1.3.6.1.4.1.9.9.826.1.12.34.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PciSlotScanDef:descr managed object property

cfprComputePciSlotScanDefIntId

1.3.6.1.4.1.9.9.826.1.12.34.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PciSlotScanDef:intId managed object property

cfprComputePciSlotScanDefName

1.3.6.1.4.1.9.9.826.1.12.34.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PciSlotScanDef:name managed object property

cfprComputePciSlotScanDefPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.34.1.7

Gauge32

Cisco Firepower compute:PciSlotScanDef:policyLevel managed object property

cfprComputePciSlotScanDefPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.34.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:PciSlotScanDef:policyOwner managed object property

cfprComputePciSlotScanDefScanOrder

1.3.6.1.4.1.9.9.826.1.12.34.1.9

Gauge32

Cisco Firepower compute:PciSlotScanDef:scanOrder managed object property

cfprComputePciSlotScanDefSlotId

1.3.6.1.4.1.9.9.826.1.12.34.1.10

Gauge32

Cisco Firepower compute:PciSlotScanDef:slotId managed object property

cfprComputePhysicalAssocCtxTable

1.3.6.1.4.1.9.9.826.1.12.35

Index: cfprComputePhysicalAssocCtxInstanceId

Cisco Firepower compute:PhysicalAssocCtx managed object table

cfprComputePhysicalAssocCtxInstanceId

1.3.6.1.4.1.9.9.826.1.12.35.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePhysicalAssocCtxDn

1.3.6.1.4.1.9.9.826.1.12.35.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PhysicalAssocCtx:dn managed object property

cfprComputePhysicalAssocCtxRn

1.3.6.1.4.1.9.9.826.1.12.35.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalAssocCtx:rn managed object property

cfprComputePhysicalAssocCtxFruCapDn

1.3.6.1.4.1.9.9.826.1.12.35.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalAssocCtx:fruCapDn managed object property

cfprComputePhysicalFsmTable

1.3.6.1.4.1.9.9.826.1.12.36

Index: cfprComputePhysicalFsmInstanceId

Cisco Firepower compute:PhysicalFsm managed object table

cfprComputePhysicalFsmInstanceId

1.3.6.1.4.1.9.9.826.1.12.36.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePhysicalFsmDn

1.3.6.1.4.1.9.9.826.1.12.36.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PhysicalFsm:dn managed object property

cfprComputePhysicalFsmRn

1.3.6.1.4.1.9.9.826.1.12.36.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalFsm:rn managed object property

cfprComputePhysicalFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.12.36.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:PhysicalFsm:completionTime managed object property

cfprComputePhysicalFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.12.36.1.5

CfprComputePhysicalFsmCurrentFsm0 = nop665 = associate727 = disassociate767 = powerCap769 = decommission771 = softShutdown773 = hardShutdown775 = turnup777 = powercycle781 = hardreset785 = softreset789 = swConnUpd792 = biosRecovery806 = cmosReset815 = resetBmc879 = updateExtUsers891 = updateAdaptor898 = activateAdaptor932 = configSoL934 = unconfigSoL1036 = diagnosticInterrupt1055 = resetKvm1152 = updateBIOS1157 = activateBIOS1200 = resetIpmi1202 = fwUpgrade1477 = cimcSessionDelete1497 = updateBoardController1506 = configBoard1508 = resetMemoryErrors1531 = serviceInfraDeploy1536 = serviceInfraWithdraw1638 = flashController1669 = enableCimcSecureBoot1991 = updateAdaptorBoot2035 = hardPowercycle · Integer32

Cisco Firepower compute:PhysicalFsm:currentFsm managed object property

cfprComputePhysicalFsmDescr

1.3.6.1.4.1.9.9.826.1.12.36.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalFsm:descr managed object property

cfprComputePhysicalFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.12.36.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:PhysicalFsm:fsmStatus managed object property

cfprComputePhysicalFsmProgress

1.3.6.1.4.1.9.9.826.1.12.36.1.8

Gauge32

Cisco Firepower compute:PhysicalFsm:progress managed object property

cfprComputePhysicalFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.12.36.1.9

Gauge32

Cisco Firepower compute:PhysicalFsm:rmtErrCode managed object property

cfprComputePhysicalFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.12.36.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalFsm:rmtErrDescr managed object property

cfprComputePhysicalFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.12.36.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:PhysicalFsm:rmtRslt managed object property

cfprComputePhysicalFsmStageTable

1.3.6.1.4.1.9.9.826.1.12.37

Index: cfprComputePhysicalFsmStageInstanceId

Cisco Firepower compute:PhysicalFsmStage managed object table

cfprComputePhysicalFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.12.37.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePhysicalFsmStageDn

1.3.6.1.4.1.9.9.826.1.12.37.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PhysicalFsmStage:dn managed object property

cfprComputePhysicalFsmStageRn

1.3.6.1.4.1.9.9.826.1.12.37.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalFsmStage:rn managed object property

cfprComputePhysicalFsmStageDescr

1.3.6.1.4.1.9.9.826.1.12.37.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalFsmStage:descr managed object property

cfprComputePhysicalFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.12.37.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:PhysicalFsmStage:lastUpdateTime managed object property

cfprComputePhysicalFsmStageName

1.3.6.1.4.1.9.9.826.1.12.37.1.6

CfprComputePhysicalFsmStageName0 = nop665 = associateBegin668 = associateUpdateIBMCFw669 = associateWaitForIBMCFwUpdate670 = associateActivateIBMCFw671 = associateResetIBMC672 = associatePreSanitize673 = associateSanitize674 = associateConfigUserAccess675 = associateBladePowerOff676 = associateUpdateBoardCtrlRequest677 = associatePollBoardCtrlUpdateStatus678 = associatePowerOn679 = associateBmcPreconfigPnuOSLocal680 = associateBmcPreconfigPnuOSPeer681 = associateBmcConfigPnuOS682 = associateSwConfigPnuOSLocal683 = associateSwConfigPnuOSPeer684 = associateUpdateAdaptorNwFwLocal685 = associateUpdateAdaptorNwFwPeer686 = associateWaitForAdaptorNwFwUpdateLocal687 = associateWaitForAdaptorNwFwUpdatePeer688 = associateActivateAdaptorNwFwLocal689 = associateActivateAdaptorNwFwPeer690 = associateNicConfigPnuOSLocal691 = associateNicConfigPnuOSPeer692 = associateBootPnuos693 = associateBootWait694 = associateBiosPostCompletion695 = associateHagPnuOSConnect696 = associatePnuOSIdent697 = associatePnuOSPolicy698 = associatePnuOSValidate699 = associatePnuOSSelfTest700 = associateBiosImgUpdate701 = associateStorageCtlrImgUpdate702 = associateHbaImgUpdate703 = associateNicImgUpdate704 = associatePnuOSInventory705 = associatePnuOSConfig706 = associatePnuOSLocalDiskConfig707 = associatePnuOSUnloadDrivers708 = associateBmcUnconfigPnuOS709 = associateNicUnconfigPnuOSLocal710 = associateNicUnconfigPnuOSPeer711 = associateSwUnconfigPnuOSLocal712 = associateSwUnconfigPnuOSPeer713 = associateSwConfigHostOSLocal714 = associateSwConfigHostOSPeer715 = associateNicConfigHostOSLocal716 = associateNicConfigHostOSPeer717 = associateHagPnuOSDisconnect718 = associateConfigSoL719 = associatePrepareForBoot720 = associateConfigUuid721 = associateBootHost722 = associateHagHostOSConnect723 = associateHostOSIdent724 = associateHostOSPolicy725 = associateHostOSValidate726 = associateHostOSConfig727 = disassociateBegin730 = disassociateConfigUserAccess731 = disassociatePowerOn732 = disassociatePreSanitize733 = disassociateSanitize734 = disassociateNicUnconfigHostOSLocal735 = disassociateNicUnconfigHostOSPeer736 = disassociateSwUnconfigHostOSLocal737 = disassociateSwUnconfigHostOSPeer738 = disassociateBmcPreconfigPnuOSLocal739 = disassociateBmcPreconfigPnuOSPeer740 = disassociateBmcConfigPnuOS741 = disassociateSwConfigPnuOSLocal742 = disassociateSwConfigPnuOSPeer743 = disassociateNicConfigPnuOSLocal744 = disassociateNicConfigPnuOSPeer745 = disassociateConfigBios746 = disassociateBootPnuos747 = disassociateBootWait748 = disassociateBiosPostCompletion749 = disassociateHagPnuOSConnect750 = disassociatePnuOSIdent751 = disassociatePnuOSPolicy752 = disassociatePnuOSValidate753 = disassociatePnuOSUnconfig754 = disassociatePnuOSScrub755 = disassociatePnuOSSelfTest756 = disassociateBmcUnconfigPnuOS757 = disassociateNicUnconfigPnuOSLocal758 = disassociateNicUnconfigPnuOSPeer759 = disassociateHagPnuOSDisconnect760 = disassociateUnconfigUuid761 = disassociateShutdown762 = disassociateUnconfigBios763 = disassociateSwUnconfigPnuOSLocal764 = disassociateSwUnconfigPnuOSPeer765 = disassociateUnconfigSoL766 = disassociateHandlePooling767 = powerCapBegin768 = powerCapConfig769 = decommissionBegin770 = decommissionExecute771 = softShutdownBegin772 = softShutdownExecute773 = hardShutdownBegin774 = hardShutdownExecute775 = turnupBegin776 = turnupExecute777 = powercycleBegin778 = powercyclePreSanitize779 = powercycleSanitize780 = powercycleExecute781 = hardresetBegin782 = hardresetPreSanitize783 = hardresetSanitize784 = hardresetExecute785 = softresetBegin786 = softresetPreSanitize787 = softresetSanitize788 = softresetExecute789 = swConnUpdBegin790 = swConnUpdA791 = swConnUpdB792 = biosRecoveryBegin793 = biosRecoveryShutdown794 = biosRecoveryPreSanitize795 = biosRecoverySanitize796 = biosRecoverySetupVmediaLocal797 = biosRecoverySetupVmediaPeer798 = biosRecoveryStart799 = biosRecoveryWait800 = biosRecoveryCleanup801 = biosRecoveryReset802 = biosRecoveryTeardownVmediaLocal803 = biosRecoveryTeardownVmediaPeer806 = cmosResetBegin807 = cmosResetPreSanitize808 = cmosResetSanitize809 = cmosResetExecute810 = cmosResetReconfigBios811 = cmosResetReconfigUuid812 = cmosResetBladePowerOn815 = resetBmcBegin816 = resetBmcExecute879 = updateExtUsersBegin880 = updateExtUsersDeploy891 = updateAdaptorBegin892 = updateAdaptorPowerOn893 = updateAdaptorUpdateRequestLocal894 = updateAdaptorUpdateRequestPeer895 = updateAdaptorPollUpdateStatusLocal896 = updateAdaptorPollUpdateStatusPeer897 = updateAdaptorPowerOff898 = activateAdaptorBegin899 = activateAdaptorPowerOn900 = activateAdaptorActivateLocal901 = activateAdaptorActivatePeer902 = activateAdaptorReset932 = configSoLBegin933 = configSoLExecute934 = unconfigSoLBegin935 = unconfigSoLExecute940 = activateAdaptorFail941 = activateAdaptorSuccess942 = associateFail943 = associateSuccess946 = biosRecoveryFail947 = biosRecoverySuccess948 = cmosResetFail949 = cmosResetSuccess950 = configSoLFail951 = configSoLSuccess952 = decommissionFail953 = decommissionSuccess954 = disassociateFail955 = disassociateSuccess956 = hardShutdownFail957 = hardShutdownSuccess958 = hardresetFail959 = hardresetSuccess960 = powerCapFail961 = powerCapSuccess962 = powercycleFail963 = powercycleSuccess964 = resetBmcFail965 = resetBmcSuccess966 = softShutdownFail967 = softShutdownSuccess968 = softresetFail969 = softresetSuccess970 = swConnUpdFail971 = swConnUpdSuccess972 = turnupFail973 = turnupSuccess974 = unconfigSoLFail975 = unconfigSoLSuccess976 = updateAdaptorFail977 = updateAdaptorSuccess978 = updateExtUsersFail979 = updateExtUsersSuccess1019 = decommissionStopVMediaLocal1020 = decommissionStopVMediaPeer1021 = biosRecoveryStopVMediaLocal1022 = biosRecoveryStopVMediaPeer1036 = diagnosticInterruptBegin1037 = diagnosticInterruptExecute1038 = diagnosticInterruptFail1039 = diagnosticInterruptSuccess1040 = associateLocalDiskFwUpdate1055 = resetKvmBegin1056 = resetKvmExecute1057 = resetKvmFail1058 = resetKvmSuccess1069 = associateSwConfigPortNivLocal1070 = associateSwConfigPortNivPeer1071 = disassociateSwConfigPortNivLocal1072 = disassociateSwConfigPortNivPeer1104 = associateSolRedirectEnable1105 = associateSerialDebugPnuOSConnect1106 = associateSerialDebugPnuOSDisconnect1107 = associateSolRedirectDisable1108 = disassociateSolRedirectEnable1109 = disassociateSerialDebugPnuOSConnect1110 = disassociateSerialDebugPnuOSDisconnect1111 = disassociateSolRedirectDisable1112 = decommissionCleanupCIMC1152 = updateBIOSBegin1153 = updateBIOSClear1154 = updateBIOSPollClearStatus1155 = updateBIOSUpdateRequest1156 = updateBIOSPollUpdateStatus1157 = activateBIOSBegin1158 = activateBIOSPowerOff1159 = activateBIOSClear1160 = activateBIOSPollClearStatus1161 = activateBIOSActivate1162 = activateBIOSPollActivateStatus1163 = activateBIOSUpdateTokens1164 = activateBIOSPowerOn1169 = associateClearBiosUpdate1170 = associatePollClearBiosUpdateStatus1171 = associateUpdateBiosRequest1172 = associatePollBiosUpdateStatus1173 = associateActivateBios1174 = associatePollBiosActivateStatus1175 = associatePnuOSCatalog1176 = disassociatePnuOSCatalog1178 = activateBIOSFail1179 = activateBIOSSuccess1180 = updateBIOSFail1181 = updateBIOSSuccess1193 = associateMarkAdapterForReboot1194 = associateDeassertResetBypass1195 = associateVerifyFcZoneConfig1196 = disassociateDeassertResetBypass1197 = disassociateVerifyFcZoneConfig1198 = decommissionCleanupPortConfigLocal1199 = decommissionCleanupPortConfigPeer1200 = resetIpmiBegin1201 = resetIpmiExecute1202 = fwUpgradeBegin1203 = fwUpgradeUpdateIBMCFw1204 = fwUpgradeWaitForIBMCFwUpdate1205 = fwUpgradeActivateIBMCFw1206 = fwUpgradeResetIBMC1207 = fwUpgradePreSanitize1208 = fwUpgradeSanitize1209 = fwUpgradeBladePowerOff1210 = fwUpgradeUpdateBoardCtrlRequest1211 = fwUpgradePollBoardCtrlUpdateStatus1212 = fwUpgradeClearBiosUpdate1213 = fwUpgradePollClearBiosUpdateStatus1214 = fwUpgradeUpdateBiosRequest1215 = fwUpgradePollBiosUpdateStatus1216 = fwUpgradeActivateBios1217 = fwUpgradePollBiosActivateStatus1218 = fwUpgradePowerOn1219 = fwUpgradeBmcPreconfigPnuOSLocal1220 = fwUpgradeBmcPreconfigPnuOSPeer1221 = fwUpgradeSwConfigPortNivLocal1222 = fwUpgradeSwConfigPortNivPeer1223 = fwUpgradeSwConfigPnuOSLocal1224 = fwUpgradeSwConfigPnuOSPeer1225 = fwUpgradeUpdateAdaptorNwFwLocal1226 = fwUpgradeUpdateAdaptorNwFwPeer1227 = fwUpgradeWaitForAdaptorNwFwUpdateLocal1228 = fwUpgradeWaitForAdaptorNwFwUpdatePeer1229 = fwUpgradeActivateAdaptorNwFwLocal1230 = fwUpgradeActivateAdaptorNwFwPeer1231 = fwUpgradeNicConfigPnuOSLocal1232 = fwUpgradeNicConfigPnuOSPeer1233 = fwUpgradeBmcConfigPnuOS1234 = fwUpgradeSolRedirectEnable1235 = fwUpgradeSerialDebugPnuOSConnect1236 = fwUpgradeBootPnuos1237 = fwUpgradeBootWait1238 = fwUpgradeBiosPostCompletion1239 = fwUpgradeHagPnuOSConnect1240 = fwUpgradePnuOSIdent1241 = fwUpgradePnuOSPolicy1242 = fwUpgradePnuOSCatalog1243 = fwUpgradePnuOSValidate1244 = fwUpgradePnuOSSelfTest1245 = fwUpgradeStorageCtlrImgUpdate1246 = fwUpgradeHbaImgUpdate1247 = fwUpgradeNicImgUpdate1248 = fwUpgradeLocalDiskFwUpdate1249 = fwUpgradePnuOSConfig1250 = fwUpgradePnuOSInventory1251 = fwUpgradeBiosImgUpdate1252 = fwUpgradePnuOSUnloadDrivers1253 = fwUpgradeBmcUnconfigPnuOS1254 = fwUpgradeNicUnconfigPnuOSLocal1255 = fwUpgradeNicUnconfigPnuOSPeer1256 = fwUpgradeSwUnconfigPnuOSLocal1257 = fwUpgradeSwUnconfigPnuOSPeer1258 = fwUpgradeDeassertResetBypass1259 = fwUpgradeHagPnuOSDisconnect1260 = fwUpgradeSerialDebugPnuOSDisconnect1261 = fwUpgradeSolRedirectDisable1262 = fwUpgradeShutdown1307 = activateAdaptorDeassertResetBypass1386 = fwUpgradeFail1387 = fwUpgradeSuccess1388 = resetIpmiFail1389 = resetIpmiSuccess1468 = associateConfigFlexFlash1469 = associateSyncPowerState1470 = disassociateUnconfigFlexFlash1477 = cimcSessionDeleteBegin1478 = cimcSessionDeleteExecute1483 = cimcSessionDeleteFail1484 = cimcSessionDeleteSuccess1497 = updateBoardControllerBegin1498 = updateBoardControllerPrepareForUpdate1499 = updateBoardControllerServerPowerOff1500 = updateBoardControllerUpdateRequest1501 = updateBoardControllerPollUpdateStatus1502 = updateBoardControllerServerPowerOn1506 = configBoardBegin1507 = configBoardConfigMemoryPolicy1508 = resetMemoryErrorsBegin1509 = resetMemoryErrorsExecute1520 = associateOobStorageInventory1521 = associateSwConfigServiceInfraLocal1522 = associateSwConfigServiceInfraPeer1523 = associateNicConfigServiceInfraLocal1524 = associateNicConfigServiceInfraPeer1525 = disassociateNicUnconfigServiceInfraLocal1526 = disassociateNicUnconfigServiceInfraPeer1527 = disassociateConfigFlexFlashScrub1531 = serviceInfraDeployBegin1532 = serviceInfraDeploySwConfigLocal1533 = serviceInfraDeploySwConfigPeer1534 = serviceInfraDeployNicConfigLocal1535 = serviceInfraDeployNicConfigPeer1536 = serviceInfraWithdrawBegin1537 = serviceInfraWithdrawSwUnConfigLocal1538 = serviceInfraWithdrawSwUnConfigPeer1539 = serviceInfraWithdrawNicUnConfigLocal1540 = serviceInfraWithdrawNicUnConfigPeer1541 = configBoardFail1542 = configBoardSuccess1543 = resetMemoryErrorsFail1544 = resetMemoryErrorsSuccess1545 = serviceInfraDeployFail1546 = serviceInfraDeploySuccess1547 = serviceInfraWithdrawFail1548 = serviceInfraWithdrawSuccess1549 = updateBoardControllerFail1550 = updateBoardControllerSuccess1561 = associatePowerOnPreConfig1562 = disassociateResetSecureBootConfig1572 = associateDownloadImages1573 = associateCopyRemote1574 = associateCheckPowerAvailability1575 = associateDeleteCurlDownloadedImages1576 = fwUpgradeDownloadImages1577 = fwUpgradeCopyRemote1578 = fwUpgradeDeleteCurlDownloadedImages1597 = updateAdaptorCheckPowerAvailability1598 = updateAdaptorPowerDeployWait1599 = activateAdaptorCheckPowerAvailability1600 = activateAdaptorPowerDeployWait1602 = associatePowerDeployWait1603 = disassociateCheckPowerAvailability1604 = disassociatePowerDeployWait1605 = fwUpgradeCheckPowerAvailability1606 = fwUpgradePowerDeployWait1620 = associateUnconfigExtMgmtRules1621 = associateUnconfigExtMgmtGw1622 = associateUnconfigCimcVMedia1623 = associateGraphicsImageUpdate1624 = associateConfigExtMgmtRules1625 = associateConfigExtMgmtGw1626 = associateConfigCimcVMedia1627 = associateSspUpdateHostPreBoot1628 = disassociateConfigKvmMgmtDefaultSetting1629 = disassociateUnconfigExtMgmtRules1630 = disassociateUnconfigExtMgmtGw1631 = disassociateUnconfigCimcVMedia1632 = decommissionUnconfigExtMgmtRules1633 = decommissionUnconfigExtMgmtGw1634 = fwUpgradeUnconfigExtMgmtRules1635 = fwUpgradeUnconfigExtMgmtGw1636 = fwUpgradeUnconfigCimcVMedia1637 = fwUpgradeGraphicsImageUpdate1638 = flashControllerBegin1639 = flashControllerUpdateFlashLife1653 = flashControllerFail1654 = flashControllerSuccess1669 = enableCimcSecureBootBegin1670 = enableCimcSecureBootUpdateRequest1671 = enableCimcSecureBootPollUpdateStatus1672 = enableCimcSecureBootActivate1673 = enableCimcSecureBootReset1676 = enableCimcSecureBootFail1677 = enableCimcSecureBootSuccess1711 = associateUpdateSspOsSoftware1712 = associateWaitForSspOsUpdateComplete1713 = associatePrepareKeyFile1991 = updateAdaptorBootBegin1992 = updateAdaptorBootCheckPowerAvailability1993 = updateAdaptorBootPowerDeployWait1994 = updateAdaptorBootPowerOn1995 = updateAdaptorBootUpdateRequestLocal1996 = updateAdaptorBootUpdateRequestPeer1997 = updateAdaptorBootPollUpdateStatusLocal1998 = updateAdaptorBootPollUpdateStatusPeer1999 = updateAdaptorBootPowerOff2000 = updateAdaptorBootFail2001 = updateAdaptorBootSuccess2035 = hardPowercycleBegin2036 = hardPowercycleExecute2068 = hardPowercycleFail2069 = hardPowercycleSuccess · Integer32

Cisco Firepower compute:PhysicalFsmStage:name managed object property

cfprComputePhysicalFsmStageOrder

1.3.6.1.4.1.9.9.826.1.12.37.1.7

Gauge32

Cisco Firepower compute:PhysicalFsmStage:order managed object property

cfprComputePhysicalFsmStageRetry

1.3.6.1.4.1.9.9.826.1.12.37.1.8

Gauge32

Cisco Firepower compute:PhysicalFsmStage:retry managed object property

cfprComputePhysicalFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.12.37.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:PhysicalFsmStage:stageStatus managed object property

cfprComputePhysicalFsmTaskTable

1.3.6.1.4.1.9.9.826.1.12.38

Index: cfprComputePhysicalFsmTaskInstanceId

Cisco Firepower compute:PhysicalFsmTask managed object table

cfprComputePhysicalFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.12.38.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePhysicalFsmTaskDn

1.3.6.1.4.1.9.9.826.1.12.38.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PhysicalFsmTask:dn managed object property

cfprComputePhysicalFsmTaskRn

1.3.6.1.4.1.9.9.826.1.12.38.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalFsmTask:rn managed object property

cfprComputePhysicalFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.12.38.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower compute:PhysicalFsmTask:completion managed object property

cfprComputePhysicalFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.12.38.1.5

CfprComputePhysicalFsmTaskFlags · BITS

Cisco Firepower compute:PhysicalFsmTask:flags managed object property

cfprComputePhysicalFsmTaskItem

1.3.6.1.4.1.9.9.826.1.12.38.1.6

CfprComputePhysicalFsmTaskItem0 = nop665 = associate727 = disassociate767 = powerCap769 = decommission771 = softShutdown773 = hardShutdown775 = turnup777 = powercycle781 = hardreset785 = softreset789 = swConnUpd792 = biosRecovery806 = cmosReset815 = resetBmc879 = updateExtUsers891 = updateAdaptor898 = activateAdaptor932 = configSoL934 = unconfigSoL1036 = diagnosticInterrupt1055 = resetKvm1152 = updateBIOS1157 = activateBIOS1200 = resetIpmi1202 = fwUpgrade1477 = cimcSessionDelete1497 = updateBoardController1506 = configBoard1508 = resetMemoryErrors1531 = serviceInfraDeploy1536 = serviceInfraWithdraw1638 = flashController1669 = enableCimcSecureBoot1991 = updateAdaptorBoot2035 = hardPowercycle · Integer32

Cisco Firepower compute:PhysicalFsmTask:item managed object property

cfprComputePhysicalFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.12.38.1.7

Gauge32

Cisco Firepower compute:PhysicalFsmTask:seqId managed object property

cfprComputePhysicalQualTable

1.3.6.1.4.1.9.9.826.1.12.39

Index: cfprComputePhysicalQualInstanceId

Cisco Firepower compute:PhysicalQual managed object table

cfprComputePhysicalQualInstanceId

1.3.6.1.4.1.9.9.826.1.12.39.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePhysicalQualDn

1.3.6.1.4.1.9.9.826.1.12.39.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PhysicalQual:dn managed object property

cfprComputePhysicalQualRn

1.3.6.1.4.1.9.9.826.1.12.39.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalQual:rn managed object property

cfprComputePhysicalQualModel

1.3.6.1.4.1.9.9.826.1.12.39.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PhysicalQual:model managed object property

cfprComputePlatformTable

1.3.6.1.4.1.9.9.826.1.12.40

Index: cfprComputePlatformInstanceId

Cisco Firepower compute:Platform managed object table

cfprComputePlatformInstanceId

1.3.6.1.4.1.9.9.826.1.12.40.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePlatformDn

1.3.6.1.4.1.9.9.826.1.12.40.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Platform:dn managed object property

cfprComputePlatformRn

1.3.6.1.4.1.9.9.826.1.12.40.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Platform:rn managed object property

cfprComputePlatformModel

1.3.6.1.4.1.9.9.826.1.12.40.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Platform:model managed object property

cfprComputePlatformProductName

1.3.6.1.4.1.9.9.826.1.12.40.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Platform:productName managed object property

cfprComputePlatformRevision

1.3.6.1.4.1.9.9.826.1.12.40.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Platform:revision managed object property

cfprComputePlatformVendor

1.3.6.1.4.1.9.9.826.1.12.40.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Platform:vendor managed object property

cfprComputePnuOSImageTable

1.3.6.1.4.1.9.9.826.1.12.41

Index: cfprComputePnuOSImageInstanceId

Cisco Firepower compute:PnuOSImage managed object table

cfprComputePnuOSImageInstanceId

1.3.6.1.4.1.9.9.826.1.12.41.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePnuOSImageDn

1.3.6.1.4.1.9.9.826.1.12.41.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PnuOSImage:dn managed object property

cfprComputePnuOSImageRn

1.3.6.1.4.1.9.9.826.1.12.41.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PnuOSImage:rn managed object property

cfprComputePnuOSImageImgLFBFFName

1.3.6.1.4.1.9.9.826.1.12.41.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PnuOSImage:imgLFBFFName managed object property

cfprComputePnuOSImageImgLoc

1.3.6.1.4.1.9.9.826.1.12.41.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PnuOSImage:imgLoc managed object property

cfprComputePnuOSImageImgName

1.3.6.1.4.1.9.9.826.1.12.41.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PnuOSImage:imgName managed object property

cfprComputePoolTable

1.3.6.1.4.1.9.9.826.1.12.42

Index: cfprComputePoolInstanceId

Cisco Firepower compute:Pool managed object table

cfprComputePoolInstanceId

1.3.6.1.4.1.9.9.826.1.12.42.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePoolDn

1.3.6.1.4.1.9.9.826.1.12.42.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Pool:dn managed object property

cfprComputePoolRn

1.3.6.1.4.1.9.9.826.1.12.42.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Pool:rn managed object property

cfprComputePoolAssigned

1.3.6.1.4.1.9.9.826.1.12.42.1.4

Gauge32

Cisco Firepower compute:Pool:assigned managed object property

cfprComputePoolAssignmentOrder

1.3.6.1.4.1.9.9.826.1.12.42.1.5

CfprPoolPoolAssignmentOrder0 = default1 = sequential · Integer32

Cisco Firepower compute:Pool:assignmentOrder managed object property

cfprComputePoolDescr

1.3.6.1.4.1.9.9.826.1.12.42.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Pool:descr managed object property

cfprComputePoolIntId

1.3.6.1.4.1.9.9.826.1.12.42.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Pool:intId managed object property

cfprComputePoolName

1.3.6.1.4.1.9.9.826.1.12.42.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Pool:name managed object property

cfprComputePoolPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.42.1.9

Gauge32

Cisco Firepower compute:Pool:policyLevel managed object property

cfprComputePoolPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.42.1.10

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:Pool:policyOwner managed object property

cfprComputePoolSize

1.3.6.1.4.1.9.9.826.1.12.42.1.11

Gauge32

Cisco Firepower compute:Pool:size managed object property

cfprComputePoolPolicyRefTable

1.3.6.1.4.1.9.9.826.1.12.43

Index: cfprComputePoolPolicyRefInstanceId

Cisco Firepower compute:PoolPolicyRef managed object table

cfprComputePoolPolicyRefInstanceId

1.3.6.1.4.1.9.9.826.1.12.43.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePoolPolicyRefDn

1.3.6.1.4.1.9.9.826.1.12.43.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PoolPolicyRef:dn managed object property

cfprComputePoolPolicyRefRn

1.3.6.1.4.1.9.9.826.1.12.43.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolPolicyRef:rn managed object property

cfprComputePoolPolicyRefId

1.3.6.1.4.1.9.9.826.1.12.43.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:PoolPolicyRef:id managed object property

cfprComputePoolPolicyRefPolicyDn

1.3.6.1.4.1.9.9.826.1.12.43.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolPolicyRef:policyDn managed object property

cfprComputePoolableTable

1.3.6.1.4.1.9.9.826.1.12.44

Index: cfprComputePoolableInstanceId

Cisco Firepower compute:Poolable managed object table

cfprComputePoolableInstanceId

1.3.6.1.4.1.9.9.826.1.12.44.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePoolableDn

1.3.6.1.4.1.9.9.826.1.12.44.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Poolable:dn managed object property

cfprComputePoolableRn

1.3.6.1.4.1.9.9.826.1.12.44.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Poolable:rn managed object property

cfprComputePoolableId

1.3.6.1.4.1.9.9.826.1.12.44.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:Poolable:id managed object property

cfprComputePoolablePoolDn

1.3.6.1.4.1.9.9.826.1.12.44.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Poolable:poolDn managed object property

cfprComputePooledRackUnitTable

1.3.6.1.4.1.9.9.826.1.12.45

Index: cfprComputePooledRackUnitInstanceId

Cisco Firepower compute:PooledRackUnit managed object table

cfprComputePooledRackUnitInstanceId

1.3.6.1.4.1.9.9.826.1.12.45.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePooledRackUnitDn

1.3.6.1.4.1.9.9.826.1.12.45.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PooledRackUnit:dn managed object property

cfprComputePooledRackUnitRn

1.3.6.1.4.1.9.9.826.1.12.45.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledRackUnit:rn managed object property

cfprComputePooledRackUnitAssigned

1.3.6.1.4.1.9.9.826.1.12.45.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:PooledRackUnit:assigned managed object property

cfprComputePooledRackUnitAssignedToDn

1.3.6.1.4.1.9.9.826.1.12.45.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledRackUnit:assignedToDn managed object property

cfprComputePooledRackUnitId

1.3.6.1.4.1.9.9.826.1.12.45.1.6

CfprComputePooledRackUnitId (1..255) · Gauge32

Cisco Firepower compute:PooledRackUnit:id managed object property

cfprComputePooledRackUnitOwner

1.3.6.1.4.1.9.9.826.1.12.45.1.7

CfprComputeOwner1 = policy2 = management · Integer32

Cisco Firepower compute:PooledRackUnit:owner managed object property

cfprComputePooledRackUnitPoolableDn

1.3.6.1.4.1.9.9.826.1.12.45.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledRackUnit:poolableDn managed object property

cfprComputePooledRackUnitPrevAssignedToDn

1.3.6.1.4.1.9.9.826.1.12.45.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledRackUnit:prevAssignedToDn managed object property

cfprComputePooledSlotTable

1.3.6.1.4.1.9.9.826.1.12.46

Index: cfprComputePooledSlotInstanceId

Cisco Firepower compute:PooledSlot managed object table

cfprComputePooledSlotInstanceId

1.3.6.1.4.1.9.9.826.1.12.46.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePooledSlotDn

1.3.6.1.4.1.9.9.826.1.12.46.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PooledSlot:dn managed object property

cfprComputePooledSlotRn

1.3.6.1.4.1.9.9.826.1.12.46.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledSlot:rn managed object property

cfprComputePooledSlotAssigned

1.3.6.1.4.1.9.9.826.1.12.46.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:PooledSlot:assigned managed object property

cfprComputePooledSlotAssignedToDn

1.3.6.1.4.1.9.9.826.1.12.46.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledSlot:assignedToDn managed object property

cfprComputePooledSlotChassisId

1.3.6.1.4.1.9.9.826.1.12.46.1.6

Gauge32

Cisco Firepower compute:PooledSlot:chassisId managed object property

cfprComputePooledSlotOwner

1.3.6.1.4.1.9.9.826.1.12.46.1.7

CfprComputeOwner1 = policy2 = management · Integer32

Cisco Firepower compute:PooledSlot:owner managed object property

cfprComputePooledSlotPoolableDn

1.3.6.1.4.1.9.9.826.1.12.46.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledSlot:poolableDn managed object property

cfprComputePooledSlotPrevAssignedToDn

1.3.6.1.4.1.9.9.826.1.12.46.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PooledSlot:prevAssignedToDn managed object property

cfprComputePooledSlotSlotId

1.3.6.1.4.1.9.9.826.1.12.46.1.10

CfprComputePooledSlotSlotId (1..8) · Gauge32

Cisco Firepower compute:PooledSlot:slotId managed object property

cfprComputePoolingPolicyTable

1.3.6.1.4.1.9.9.826.1.12.47

Index: cfprComputePoolingPolicyInstanceId

Cisco Firepower compute:PoolingPolicy managed object table

cfprComputePoolingPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.47.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePoolingPolicyDn

1.3.6.1.4.1.9.9.826.1.12.47.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PoolingPolicy:dn managed object property

cfprComputePoolingPolicyRn

1.3.6.1.4.1.9.9.826.1.12.47.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolingPolicy:rn managed object property

cfprComputePoolingPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.47.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolingPolicy:descr managed object property

cfprComputePoolingPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.47.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolingPolicy:intId managed object property

cfprComputePoolingPolicyName

1.3.6.1.4.1.9.9.826.1.12.47.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolingPolicy:name managed object property

cfprComputePoolingPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.47.1.7

Gauge32

Cisco Firepower compute:PoolingPolicy:policyLevel managed object property

cfprComputePoolingPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.47.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:PoolingPolicy:policyOwner managed object property

cfprComputePoolingPolicyPoolDn

1.3.6.1.4.1.9.9.826.1.12.47.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolingPolicy:poolDn managed object property

cfprComputePoolingPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.47.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PoolingPolicy:qualifier managed object property

cfprComputePsuControlTable

1.3.6.1.4.1.9.9.826.1.12.48

Index: cfprComputePsuControlInstanceId

Cisco Firepower compute:PsuControl managed object table

cfprComputePsuControlInstanceId

1.3.6.1.4.1.9.9.826.1.12.48.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePsuControlDn

1.3.6.1.4.1.9.9.826.1.12.48.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PsuControl:dn managed object property

cfprComputePsuControlRn

1.3.6.1.4.1.9.9.826.1.12.48.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuControl:rn managed object property

cfprComputePsuControlClusterState

1.3.6.1.4.1.9.9.826.1.12.48.1.4

CfprComputePsuClusterState0 = unknown1 = slot1Master2 = slot2Master3 = notClustered · Integer32

Cisco Firepower compute:PsuControl:clusterState managed object property

cfprComputePsuControlDescr

1.3.6.1.4.1.9.9.826.1.12.48.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuControl:descr managed object property

cfprComputePsuControlInputPowerState

1.3.6.1.4.1.9.9.826.1.12.48.1.6

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:PsuControl:inputPowerState managed object property

cfprComputePsuControlIntId

1.3.6.1.4.1.9.9.826.1.12.48.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuControl:intId managed object property

cfprComputePsuControlName

1.3.6.1.4.1.9.9.826.1.12.48.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuControl:name managed object property

cfprComputePsuControlOperQualifier

1.3.6.1.4.1.9.9.826.1.12.48.1.9

CfprComputePsuRedundancyOperQualifier · BITS

Cisco Firepower compute:PsuControl:operQualifier managed object property

cfprComputePsuControlOperState

1.3.6.1.4.1.9.9.826.1.12.48.1.10

CfprComputePsuRedundancyOperState0 = unknown1 = ok2 = failed3 = degraded · Integer32

Cisco Firepower compute:PsuControl:operState managed object property

cfprComputePsuControlOutputPowerState

1.3.6.1.4.1.9.9.826.1.12.48.1.11

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:PsuControl:outputPowerState managed object property

cfprComputePsuControlPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.48.1.12

Gauge32

Cisco Firepower compute:PsuControl:policyLevel managed object property

cfprComputePsuControlPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.48.1.13

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:PsuControl:policyOwner managed object property

cfprComputePsuControlRedundancy

1.3.6.1.4.1.9.9.826.1.12.48.1.14

CfprComputePsuControlRedundancy0 = unknown1 = nonRedundant2 = nPlus13 = grid · Integer32

Cisco Firepower compute:PsuControl:redundancy managed object property

cfprComputePsuPolicyTable

1.3.6.1.4.1.9.9.826.1.12.49

Index: cfprComputePsuPolicyInstanceId

Cisco Firepower compute:PsuPolicy managed object table

cfprComputePsuPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.49.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputePsuPolicyDn

1.3.6.1.4.1.9.9.826.1.12.49.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:PsuPolicy:dn managed object property

cfprComputePsuPolicyRn

1.3.6.1.4.1.9.9.826.1.12.49.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuPolicy:rn managed object property

cfprComputePsuPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.49.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuPolicy:descr managed object property

cfprComputePsuPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.49.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuPolicy:intId managed object property

cfprComputePsuPolicyName

1.3.6.1.4.1.9.9.826.1.12.49.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:PsuPolicy:name managed object property

cfprComputePsuPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.49.1.7

Gauge32

Cisco Firepower compute:PsuPolicy:policyLevel managed object property

cfprComputePsuPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.49.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:PsuPolicy:policyOwner managed object property

cfprComputePsuPolicyRedundancy

1.3.6.1.4.1.9.9.826.1.12.49.1.9

CfprComputePsuRedundancy1 = nonRedundant2 = nPlus13 = grid · Integer32

Cisco Firepower compute:PsuPolicy:redundancy managed object property

cfprComputeQualTable

1.3.6.1.4.1.9.9.826.1.12.50

Index: cfprComputeQualInstanceId

Cisco Firepower compute:Qual managed object table

cfprComputeQualInstanceId

1.3.6.1.4.1.9.9.826.1.12.50.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeQualDn

1.3.6.1.4.1.9.9.826.1.12.50.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:Qual:dn managed object property

cfprComputeQualRn

1.3.6.1.4.1.9.9.826.1.12.50.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Qual:rn managed object property

cfprComputeQualDescr

1.3.6.1.4.1.9.9.826.1.12.50.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Qual:descr managed object property

cfprComputeQualIntId

1.3.6.1.4.1.9.9.826.1.12.50.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Qual:intId managed object property

cfprComputeQualName

1.3.6.1.4.1.9.9.826.1.12.50.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:Qual:name managed object property

cfprComputeQualPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.50.1.7

Gauge32

Cisco Firepower compute:Qual:policyLevel managed object property

cfprComputeQualPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.50.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:Qual:policyOwner managed object property

cfprComputeRackQualTable

1.3.6.1.4.1.9.9.826.1.12.51

Index: cfprComputeRackQualInstanceId

Cisco Firepower compute:RackQual managed object table

cfprComputeRackQualInstanceId

1.3.6.1.4.1.9.9.826.1.12.51.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackQualDn

1.3.6.1.4.1.9.9.826.1.12.51.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackQual:dn managed object property

cfprComputeRackQualRn

1.3.6.1.4.1.9.9.826.1.12.51.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackQual:rn managed object property

cfprComputeRackQualMaxId

1.3.6.1.4.1.9.9.826.1.12.51.1.4

CfprComputeRackQualMaxId (1..255) · Gauge32

Cisco Firepower compute:RackQual:maxId managed object property

cfprComputeRackQualMinId

1.3.6.1.4.1.9.9.826.1.12.51.1.5

CfprComputeRackQualMinId (1..255) · Gauge32

Cisco Firepower compute:RackQual:minId managed object property

cfprComputeRackUnitTable

1.3.6.1.4.1.9.9.826.1.12.52

Index: cfprComputeRackUnitInstanceId

Cisco Firepower compute:RackUnit managed object table

cfprComputeRackUnitInstanceId

1.3.6.1.4.1.9.9.826.1.12.52.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackUnitDn

1.3.6.1.4.1.9.9.826.1.12.52.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackUnit:dn managed object property

cfprComputeRackUnitRn

1.3.6.1.4.1.9.9.826.1.12.52.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:rn managed object property

cfprComputeRackUnitAdminPower

1.3.6.1.4.1.9.9.826.1.12.52.1.4

CfprComputeAdminPowerState2 = cycleImmediate3 = cycleWait4 = hardResetImmediate5 = hardResetWait12 = cmosResetImmediate13 = bmcResetImmediate14 = bmcResetWait15 = diagnosticInterrupt16 = kvmReset30 = policy31 = adminUp32 = adminDown33 = ipmiReset · Integer32

Cisco Firepower compute:RackUnit:adminPower managed object property

cfprComputeRackUnitAdminState

1.3.6.1.4.1.9.9.826.1.12.52.1.5

CfprComputeAdminState1 = inService2 = outOfService · Integer32

Cisco Firepower compute:RackUnit:adminState managed object property

cfprComputeRackUnitAssignedToDn

1.3.6.1.4.1.9.9.826.1.12.52.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:assignedToDn managed object property

cfprComputeRackUnitAssociation

1.3.6.1.4.1.9.9.826.1.12.52.1.7

CfprComputeAssociation0 = none1 = establishing2 = associated3 = removing4 = failed5 = throttled · Integer32

Cisco Firepower compute:RackUnit:association managed object property

cfprComputeRackUnitAvailability

1.3.6.1.4.1.9.9.826.1.12.52.1.8

CfprComputeAvailability0 = unavailable1 = available · Integer32

Cisco Firepower compute:RackUnit:availability managed object property

cfprComputeRackUnitAvailableMemory

1.3.6.1.4.1.9.9.826.1.12.52.1.9

Gauge32

Cisco Firepower compute:RackUnit:availableMemory managed object property

cfprComputeRackUnitCheckPoint

1.3.6.1.4.1.9.9.826.1.12.52.1.10

CfprComputeCheckPoint0 = unknown1 = removing2 = shallowCheckpoint3 = deepCheckpoint4 = discovered · Integer32

Cisco Firepower compute:RackUnit:checkPoint managed object property

cfprComputeRackUnitConnPath

1.3.6.1.4.1.9.9.826.1.12.52.1.11

CfprEquipmentConnectionStatus · BITS

Cisco Firepower compute:RackUnit:connPath managed object property

cfprComputeRackUnitConnStatus

1.3.6.1.4.1.9.9.826.1.12.52.1.12

CfprEquipmentConnectionStatus · BITS

Cisco Firepower compute:RackUnit:connStatus managed object property

cfprComputeRackUnitDescr

1.3.6.1.4.1.9.9.826.1.12.52.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:descr managed object property

cfprComputeRackUnitDiscovery

1.3.6.1.4.1.9.9.826.1.12.52.1.14

CfprComputeDiscovery0 = undiscovered1 = inProgress2 = malformedFruInfo3 = fruNotReady4 = insufficientlyEquipped5 = invalidAdaptorIocard8 = failed16 = complete32 = retry64 = throttled128 = illegalFru129 = fruIdentityIndeterminate130 = fruStateIndeterminate131 = diagnosticsInProgress132 = efidiagnosticsInProgress133 = diagnosticsFailed134 = diagnosticsComplete135 = waitingForUserAck136 = userAcknowledged137 = waitingForMgmtAck138 = illegalPartNumber · Integer32

Cisco Firepower compute:RackUnit:discovery managed object property

cfprComputeRackUnitFltAggr

1.3.6.1.4.1.9.9.826.1.12.52.1.15

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:RackUnit:fltAggr managed object property

cfprComputeRackUnitFsmDescr

1.3.6.1.4.1.9.9.826.1.12.52.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:fsmDescr managed object property

cfprComputeRackUnitFsmFlags

1.3.6.1.4.1.9.9.826.1.12.52.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:fsmFlags managed object property

cfprComputeRackUnitFsmPrev

1.3.6.1.4.1.9.9.826.1.12.52.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:fsmPrev managed object property

cfprComputeRackUnitFsmProgr

1.3.6.1.4.1.9.9.826.1.12.52.1.19

Gauge32

Cisco Firepower compute:RackUnit:fsmProgr managed object property

cfprComputeRackUnitFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.12.52.1.20

Gauge32

Cisco Firepower compute:RackUnit:fsmRmtInvErrCode managed object property

cfprComputeRackUnitFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.12.52.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:fsmRmtInvErrDescr managed object property

cfprComputeRackUnitFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.12.52.1.22

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:RackUnit:fsmRmtInvRslt managed object property

cfprComputeRackUnitFsmStageDescr

1.3.6.1.4.1.9.9.826.1.12.52.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:fsmStageDescr managed object property

cfprComputeRackUnitFsmStamp

1.3.6.1.4.1.9.9.826.1.12.52.1.24

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnit:fsmStamp managed object property

cfprComputeRackUnitFsmStatus

1.3.6.1.4.1.9.9.826.1.12.52.1.25

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:fsmStatus managed object property

cfprComputeRackUnitFsmTry

1.3.6.1.4.1.9.9.826.1.12.52.1.26

Gauge32

Cisco Firepower compute:RackUnit:fsmTry managed object property

cfprComputeRackUnitId

1.3.6.1.4.1.9.9.826.1.12.52.1.27

CfprComputeRackUnitId (1..255) · Gauge32

Cisco Firepower compute:RackUnit:id managed object property

cfprComputeRackUnitIntId

1.3.6.1.4.1.9.9.826.1.12.52.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:intId managed object property

cfprComputeRackUnitLc

1.3.6.1.4.1.9.9.826.1.12.52.1.29

CfprComputeAdminTrigger0 = undiscovered1 = rediscover2 = resetToFactory3 = discovered4 = remove5 = migrate6 = decommission7 = upgradeFirmware8 = decommissionSecure · Integer32

Cisco Firepower compute:RackUnit:lc managed object property

cfprComputeRackUnitLcTs

1.3.6.1.4.1.9.9.826.1.12.52.1.30

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnit:lcTs managed object property

cfprComputeRackUnitLocalId

1.3.6.1.4.1.9.9.826.1.12.52.1.31

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:localId managed object property

cfprComputeRackUnitLowVoltageMemory

1.3.6.1.4.1.9.9.826.1.12.52.1.32

CfprComputePhysicalLowVoltageMemory0 = notApplicable1 = lowVoltage2 = regularVoltage · Integer32

Cisco Firepower compute:RackUnit:lowVoltageMemory managed object property

cfprComputeRackUnitManagingInst

1.3.6.1.4.1.9.9.826.1.12.52.1.33

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower compute:RackUnit:managingInst managed object property

cfprComputeRackUnitMemorySpeed

1.3.6.1.4.1.9.9.826.1.12.52.1.34

Gauge32

Cisco Firepower compute:RackUnit:memorySpeed managed object property

cfprComputeRackUnitMfgTime

1.3.6.1.4.1.9.9.826.1.12.52.1.35

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnit:mfgTime managed object property

cfprComputeRackUnitModel

1.3.6.1.4.1.9.9.826.1.12.52.1.36

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:model managed object property

cfprComputeRackUnitName

1.3.6.1.4.1.9.9.826.1.12.52.1.37

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:name managed object property

cfprComputeRackUnitNumOfAdaptors

1.3.6.1.4.1.9.9.826.1.12.52.1.38

Gauge32

Cisco Firepower compute:RackUnit:numOfAdaptors managed object property

cfprComputeRackUnitNumOfCores

1.3.6.1.4.1.9.9.826.1.12.52.1.39

Gauge32

Cisco Firepower compute:RackUnit:numOfCores managed object property

cfprComputeRackUnitNumOfCoresEnabled

1.3.6.1.4.1.9.9.826.1.12.52.1.40

Gauge32

Cisco Firepower compute:RackUnit:numOfCoresEnabled managed object property

cfprComputeRackUnitNumOfCpus

1.3.6.1.4.1.9.9.826.1.12.52.1.41

Gauge32

Cisco Firepower compute:RackUnit:numOfCpus managed object property

cfprComputeRackUnitNumOfEthHostIfs

1.3.6.1.4.1.9.9.826.1.12.52.1.42

Gauge32

Cisco Firepower compute:RackUnit:numOfEthHostIfs managed object property

cfprComputeRackUnitNumOfFcHostIfs

1.3.6.1.4.1.9.9.826.1.12.52.1.43

Gauge32

Cisco Firepower compute:RackUnit:numOfFcHostIfs managed object property

cfprComputeRackUnitNumOfThreads

1.3.6.1.4.1.9.9.826.1.12.52.1.44

Gauge32

Cisco Firepower compute:RackUnit:numOfThreads managed object property

cfprComputeRackUnitOperPower

1.3.6.1.4.1.9.9.826.1.12.52.1.45

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:RackUnit:operPower managed object property

cfprComputeRackUnitOperQualifier

1.3.6.1.4.1.9.9.826.1.12.52.1.46

CfprComputeIssues · BITS

Cisco Firepower compute:RackUnit:operQualifier managed object property

cfprComputeRackUnitOperState

1.3.6.1.4.1.9.9.826.1.12.52.1.47

CfprLsOperState0 = indeterminate1 = unassociated10 = ok11 = discovery12 = config13 = unconfig14 = powerOff15 = restart20 = maintenance21 = test29 = computeMismatch30 = computeFailed31 = degraded32 = discoveryFailed33 = configFailure34 = unconfigFailed35 = testFailed36 = maintenanceFailed40 = removed41 = disabled50 = inaccessible60 = thermalProblem61 = powerProblem62 = voltageProblem63 = inoperable101 = decomissioning102 = decomissioned201 = biosRestore202 = cmosReset203 = diagnostics204 = diagnosticsFailed210 = pendingReboot211 = pendingReassociation212 = svnicNotPresent · Integer32

Cisco Firepower compute:RackUnit:operState managed object property

cfprComputeRackUnitOperability

1.3.6.1.4.1.9.9.826.1.12.52.1.48

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:RackUnit:operability managed object property

cfprComputeRackUnitOriginalUuid

1.3.6.1.4.1.9.9.826.1.12.52.1.49

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:originalUuid managed object property

cfprComputeRackUnitPartNumber

1.3.6.1.4.1.9.9.826.1.12.52.1.50

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:partNumber managed object property

cfprComputeRackUnitPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.52.1.51

Gauge32

Cisco Firepower compute:RackUnit:policyLevel managed object property

cfprComputeRackUnitPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.52.1.52

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:RackUnit:policyOwner managed object property

cfprComputeRackUnitPresence

1.3.6.1.4.1.9.9.826.1.12.52.1.53

CfprEquipmentSlotStatus0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized · Integer32

Cisco Firepower compute:RackUnit:presence managed object property

cfprComputeRackUnitRevision

1.3.6.1.4.1.9.9.826.1.12.52.1.54

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:revision managed object property

cfprComputeRackUnitSerial

1.3.6.1.4.1.9.9.826.1.12.52.1.55

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:serial managed object property

cfprComputeRackUnitServerId

1.3.6.1.4.1.9.9.826.1.12.52.1.56

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:serverId managed object property

cfprComputeRackUnitTotalMemory

1.3.6.1.4.1.9.9.826.1.12.52.1.57

Gauge32

Cisco Firepower compute:RackUnit:totalMemory managed object property

cfprComputeRackUnitUsrLbl

1.3.6.1.4.1.9.9.826.1.12.52.1.58

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:usrLbl managed object property

cfprComputeRackUnitUuid

1.3.6.1.4.1.9.9.826.1.12.52.1.59

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:uuid managed object property

cfprComputeRackUnitVendor

1.3.6.1.4.1.9.9.826.1.12.52.1.60

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:vendor managed object property

cfprComputeRackUnitVersionHolder

1.3.6.1.4.1.9.9.826.1.12.52.1.61

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:RackUnit:versionHolder managed object property

cfprComputeRackUnitVid

1.3.6.1.4.1.9.9.826.1.12.52.1.62

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnit:vid managed object property

cfprComputeRackUnitPostState

1.3.6.1.4.1.9.9.826.1.12.52.1.63

CfprEquipmentBiosPostState0 = unknown1 = complete2 = notComplete3 = timeout · Integer32

Cisco Firepower compute:RackUnit:postState managed object property

cfprComputeRackUnitFsmTable

1.3.6.1.4.1.9.9.826.1.12.53

Index: cfprComputeRackUnitFsmInstanceId

Cisco Firepower compute:RackUnitFsm managed object table

cfprComputeRackUnitFsmInstanceId

1.3.6.1.4.1.9.9.826.1.12.53.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackUnitFsmDn

1.3.6.1.4.1.9.9.826.1.12.53.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackUnitFsm:dn managed object property

cfprComputeRackUnitFsmRn

1.3.6.1.4.1.9.9.826.1.12.53.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitFsm:rn managed object property

cfprComputeRackUnitFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.12.53.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnitFsm:completionTime managed object property

cfprComputeRackUnitFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.12.53.1.5

CfprComputeRackUnitFsmCurrentFsm0 = nop665 = associate727 = disassociate767 = powerCap769 = decommission771 = softShutdown773 = hardShutdown775 = turnup777 = powercycle781 = hardreset785 = softreset789 = swConnUpd792 = biosRecovery806 = cmosReset815 = resetBmc819 = discover879 = updateExtUsers891 = updateAdaptor898 = activateAdaptor932 = configSoL934 = unconfigSoL1036 = diagnosticInterrupt1055 = resetKvm1064 = offline1152 = updateBIOS1157 = activateBIOS1200 = resetIpmi1202 = fwUpgrade1263 = adapterReset1477 = cimcSessionDelete1497 = updateBoardController1506 = configBoard1508 = resetMemoryErrors1528 = createDhcpEntry1531 = serviceInfraDeploy1536 = serviceInfraWithdraw1638 = flashController1669 = enableCimcSecureBoot1991 = updateAdaptorBoot2035 = hardPowercycle · Integer32

Cisco Firepower compute:RackUnitFsm:currentFsm managed object property

cfprComputeRackUnitFsmDescrData

1.3.6.1.4.1.9.9.826.1.12.53.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitFsm:descr managed object property

cfprComputeRackUnitFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.12.53.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:RackUnitFsm:fsmStatus managed object property

cfprComputeRackUnitFsmProgress

1.3.6.1.4.1.9.9.826.1.12.53.1.8

Gauge32

Cisco Firepower compute:RackUnitFsm:progress managed object property

cfprComputeRackUnitFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.12.53.1.9

Gauge32

Cisco Firepower compute:RackUnitFsm:rmtErrCode managed object property

cfprComputeRackUnitFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.12.53.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitFsm:rmtErrDescr managed object property

cfprComputeRackUnitFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.12.53.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:RackUnitFsm:rmtRslt managed object property

cfprComputeRackUnitFsmStageTable

1.3.6.1.4.1.9.9.826.1.12.54

Index: cfprComputeRackUnitFsmStageInstanceId

Cisco Firepower compute:RackUnitFsmStage managed object table

cfprComputeRackUnitFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.12.54.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackUnitFsmStageDn

1.3.6.1.4.1.9.9.826.1.12.54.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackUnitFsmStage:dn managed object property

cfprComputeRackUnitFsmStageRn

1.3.6.1.4.1.9.9.826.1.12.54.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitFsmStage:rn managed object property

cfprComputeRackUnitFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.12.54.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitFsmStage:descr managed object property

cfprComputeRackUnitFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.12.54.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnitFsmStage:lastUpdateTime managed object property

cfprComputeRackUnitFsmStageName

1.3.6.1.4.1.9.9.826.1.12.54.1.6

CfprComputeRackUnitFsmStageName0 = nop665 = associateBegin668 = associateUpdateIBMCFw669 = associateWaitForIBMCFwUpdate670 = associateActivateIBMCFw671 = associateResetIBMC672 = associatePreSanitize673 = associateSanitize674 = associateConfigUserAccess675 = associateBladePowerOff676 = associateUpdateBoardCtrlRequest677 = associatePollBoardCtrlUpdateStatus678 = associatePowerOn679 = associateBmcPreconfigPnuOSLocal680 = associateBmcPreconfigPnuOSPeer681 = associateBmcConfigPnuOS682 = associateSwConfigPnuOSLocal683 = associateSwConfigPnuOSPeer684 = associateUpdateAdaptorNwFwLocal685 = associateUpdateAdaptorNwFwPeer686 = associateWaitForAdaptorNwFwUpdateLocal687 = associateWaitForAdaptorNwFwUpdatePeer688 = associateActivateAdaptorNwFwLocal689 = associateActivateAdaptorNwFwPeer690 = associateNicConfigPnuOSLocal691 = associateNicConfigPnuOSPeer692 = associateBootPnuos693 = associateBootWait694 = associateBiosPostCompletion695 = associateHagPnuOSConnect696 = associatePnuOSIdent697 = associatePnuOSPolicy698 = associatePnuOSValidate699 = associatePnuOSSelfTest700 = associateBiosImgUpdate701 = associateStorageCtlrImgUpdate702 = associateHbaImgUpdate703 = associateNicImgUpdate704 = associatePnuOSInventory705 = associatePnuOSConfig706 = associatePnuOSLocalDiskConfig707 = associatePnuOSUnloadDrivers708 = associateBmcUnconfigPnuOS709 = associateNicUnconfigPnuOSLocal710 = associateNicUnconfigPnuOSPeer711 = associateSwUnconfigPnuOSLocal712 = associateSwUnconfigPnuOSPeer713 = associateSwConfigHostOSLocal714 = associateSwConfigHostOSPeer715 = associateNicConfigHostOSLocal716 = associateNicConfigHostOSPeer717 = associateHagPnuOSDisconnect718 = associateConfigSoL719 = associatePrepareForBoot720 = associateConfigUuid721 = associateBootHost722 = associateHagHostOSConnect723 = associateHostOSIdent724 = associateHostOSPolicy725 = associateHostOSValidate726 = associateHostOSConfig727 = disassociateBegin730 = disassociateConfigUserAccess731 = disassociatePowerOn732 = disassociatePreSanitize733 = disassociateSanitize734 = disassociateNicUnconfigHostOSLocal735 = disassociateNicUnconfigHostOSPeer736 = disassociateSwUnconfigHostOSLocal737 = disassociateSwUnconfigHostOSPeer738 = disassociateBmcPreconfigPnuOSLocal739 = disassociateBmcPreconfigPnuOSPeer740 = disassociateBmcConfigPnuOS741 = disassociateSwConfigPnuOSLocal742 = disassociateSwConfigPnuOSPeer743 = disassociateNicConfigPnuOSLocal744 = disassociateNicConfigPnuOSPeer745 = disassociateConfigBios746 = disassociateBootPnuos747 = disassociateBootWait748 = disassociateBiosPostCompletion749 = disassociateHagPnuOSConnect750 = disassociatePnuOSIdent751 = disassociatePnuOSPolicy752 = disassociatePnuOSValidate753 = disassociatePnuOSUnconfig754 = disassociatePnuOSScrub755 = disassociatePnuOSSelfTest756 = disassociateBmcUnconfigPnuOS757 = disassociateNicUnconfigPnuOSLocal758 = disassociateNicUnconfigPnuOSPeer759 = disassociateHagPnuOSDisconnect760 = disassociateUnconfigUuid761 = disassociateShutdown762 = disassociateUnconfigBios763 = disassociateSwUnconfigPnuOSLocal764 = disassociateSwUnconfigPnuOSPeer765 = disassociateUnconfigSoL766 = disassociateHandlePooling767 = powerCapBegin768 = powerCapConfig769 = decommissionBegin770 = decommissionExecute771 = softShutdownBegin772 = softShutdownExecute773 = hardShutdownBegin774 = hardShutdownExecute775 = turnupBegin776 = turnupExecute777 = powercycleBegin778 = powercyclePreSanitize779 = powercycleSanitize780 = powercycleExecute781 = hardresetBegin782 = hardresetPreSanitize783 = hardresetSanitize784 = hardresetExecute785 = softresetBegin786 = softresetPreSanitize787 = softresetSanitize788 = softresetExecute789 = swConnUpdBegin790 = swConnUpdA791 = swConnUpdB792 = biosRecoveryBegin793 = biosRecoveryShutdown794 = biosRecoveryPreSanitize795 = biosRecoverySanitize796 = biosRecoverySetupVmediaLocal797 = biosRecoverySetupVmediaPeer798 = biosRecoveryStart799 = biosRecoveryWait800 = biosRecoveryCleanup801 = biosRecoveryReset802 = biosRecoveryTeardownVmediaLocal803 = biosRecoveryTeardownVmediaPeer806 = cmosResetBegin807 = cmosResetPreSanitize808 = cmosResetSanitize809 = cmosResetExecute810 = cmosResetReconfigBios811 = cmosResetReconfigUuid812 = cmosResetBladePowerOn815 = resetBmcBegin816 = resetBmcExecute819 = discoverBegin820 = discoverBmcConfigureConnLocal821 = discoverSwConfigureConnLocal822 = discoverBmcConfigureConnPeer823 = discoverSwConfigureConnPeer826 = discoverBmcPresence827 = discoverBmcInventory828 = discoverPreSanitize829 = discoverSanitize830 = discoverConfigUserAccess831 = discoverSwConfigPnuOSLocal832 = discoverSwConfigPnuOSPeer833 = discoverBmcPreconfigPnuOSLocal834 = discoverBmcPreconfigPnuOSPeer835 = discoverBmcConfigPnuOS836 = discoverBootPnuos837 = discoverBootWait838 = discoverBiosPostCompletion839 = discoverReadSmbios841 = discoverHagConnect842 = discoverPnuOSIdent843 = discoverPnuOSPolicy844 = discoverPnuOSInventory845 = discoverPnuOSScrub846 = discoverPnuOSConnectivity847 = discoverPnuOSConnStatus848 = discoverSwPnuOSConnectivityLocal849 = discoverSwPnuOSConnectivityPeer850 = discoverPnuOSSelfTest851 = discoverBmcUnconfigPnuOS852 = discoverHagDisconnect853 = discoverBmcShutdownDiscovered854 = discoverHandlePooling855 = discoverSuccess856 = discoverFail879 = updateExtUsersBegin880 = updateExtUsersDeploy891 = updateAdaptorBegin892 = updateAdaptorPowerOn893 = updateAdaptorUpdateRequestLocal894 = updateAdaptorUpdateRequestPeer895 = updateAdaptorPollUpdateStatusLocal896 = updateAdaptorPollUpdateStatusPeer897 = updateAdaptorPowerOff898 = activateAdaptorBegin899 = activateAdaptorPowerOn900 = activateAdaptorActivateLocal901 = activateAdaptorActivatePeer902 = activateAdaptorReset932 = configSoLBegin933 = configSoLExecute934 = unconfigSoLBegin935 = unconfigSoLExecute940 = activateAdaptorFail941 = activateAdaptorSuccess942 = associateFail943 = associateSuccess946 = biosRecoveryFail947 = biosRecoverySuccess948 = cmosResetFail949 = cmosResetSuccess950 = configSoLFail951 = configSoLSuccess952 = decommissionFail953 = decommissionSuccess954 = disassociateFail955 = disassociateSuccess956 = hardShutdownFail957 = hardShutdownSuccess958 = hardresetFail959 = hardresetSuccess960 = powerCapFail961 = powerCapSuccess962 = powercycleFail963 = powercycleSuccess964 = resetBmcFail965 = resetBmcSuccess966 = softShutdownFail967 = softShutdownSuccess968 = softresetFail969 = softresetSuccess970 = swConnUpdFail971 = swConnUpdSuccess972 = turnupFail973 = turnupSuccess974 = unconfigSoLFail975 = unconfigSoLSuccess976 = updateAdaptorFail977 = updateAdaptorSuccess978 = updateExtUsersFail979 = updateExtUsersSuccess1019 = decommissionStopVMediaLocal1020 = decommissionStopVMediaPeer1021 = biosRecoveryStopVMediaLocal1022 = biosRecoveryStopVMediaPeer1023 = discoverConfigDiscoveryMode1024 = discoverSwUnconfigPortNivLocal1025 = discoverSwUnconfigPortNivPeer1027 = discoverSwConfigPortNivLocal1028 = discoverSwConfigPortNivPeer1029 = discoverNicInventoryLocal1030 = discoverNicInventoryPeer1031 = discoverConfigNivMode1036 = diagnosticInterruptBegin1037 = diagnosticInterruptExecute1038 = diagnosticInterruptFail1039 = diagnosticInterruptSuccess1040 = associateLocalDiskFwUpdate1050 = discoverWaitForConnReady1055 = resetKvmBegin1056 = resetKvmExecute1057 = resetKvmFail1058 = resetKvmSuccess1064 = offlineBegin1065 = offlineCleanupLocal1066 = offlineCleanupPeer1067 = offlineSwUnconfigureLocal1068 = offlineSwUnconfigurePeer1069 = associateSwConfigPortNivLocal1070 = associateSwConfigPortNivPeer1071 = disassociateSwConfigPortNivLocal1072 = disassociateSwConfigPortNivPeer1073 = offlineFail1074 = offlineSuccess1092 = discoverSolRedirectEnable1093 = discoverSerialDebugConnect1094 = discoverSerialDebugDisconnect1095 = discoverSolRedirectDisable1104 = associateSolRedirectEnable1105 = associateSerialDebugPnuOSConnect1106 = associateSerialDebugPnuOSDisconnect1107 = associateSolRedirectDisable1108 = disassociateSolRedirectEnable1109 = disassociateSerialDebugPnuOSConnect1110 = disassociateSerialDebugPnuOSDisconnect1111 = disassociateSolRedirectDisable1112 = decommissionCleanupCIMC1152 = updateBIOSBegin1153 = updateBIOSClear1154 = updateBIOSPollClearStatus1155 = updateBIOSUpdateRequest1156 = updateBIOSPollUpdateStatus1157 = activateBIOSBegin1158 = activateBIOSPowerOff1159 = activateBIOSClear1160 = activateBIOSPollClearStatus1161 = activateBIOSActivate1162 = activateBIOSPollActivateStatus1163 = activateBIOSUpdateTokens1164 = activateBIOSPowerOn1169 = associateClearBiosUpdate1170 = associatePollClearBiosUpdateStatus1171 = associateUpdateBiosRequest1172 = associatePollBiosUpdateStatus1173 = associateActivateBios1174 = associatePollBiosActivateStatus1175 = associatePnuOSCatalog1176 = disassociatePnuOSCatalog1177 = discoverPnuOSCatalog1178 = activateBIOSFail1179 = activateBIOSSuccess1180 = updateBIOSFail1181 = updateBIOSSuccess1189 = discoverBladePowerOff1190 = discoverNicConfigPnuOSLocal1191 = discoverNicConfigPnuOSPeer1193 = associateMarkAdapterForReboot1194 = associateDeassertResetBypass1195 = associateVerifyFcZoneConfig1196 = disassociateDeassertResetBypass1197 = disassociateVerifyFcZoneConfig1198 = decommissionCleanupPortConfigLocal1199 = decommissionCleanupPortConfigPeer1200 = resetIpmiBegin1201 = resetIpmiExecute1202 = fwUpgradeBegin1203 = fwUpgradeUpdateIBMCFw1204 = fwUpgradeWaitForIBMCFwUpdate1205 = fwUpgradeActivateIBMCFw1206 = fwUpgradeResetIBMC1207 = fwUpgradePreSanitize1208 = fwUpgradeSanitize1209 = fwUpgradeBladePowerOff1210 = fwUpgradeUpdateBoardCtrlRequest1211 = fwUpgradePollBoardCtrlUpdateStatus1212 = fwUpgradeClearBiosUpdate1213 = fwUpgradePollClearBiosUpdateStatus1214 = fwUpgradeUpdateBiosRequest1215 = fwUpgradePollBiosUpdateStatus1216 = fwUpgradeActivateBios1217 = fwUpgradePollBiosActivateStatus1218 = fwUpgradePowerOn1219 = fwUpgradeBmcPreconfigPnuOSLocal1220 = fwUpgradeBmcPreconfigPnuOSPeer1221 = fwUpgradeSwConfigPortNivLocal1222 = fwUpgradeSwConfigPortNivPeer1223 = fwUpgradeSwConfigPnuOSLocal1224 = fwUpgradeSwConfigPnuOSPeer1225 = fwUpgradeUpdateAdaptorNwFwLocal1226 = fwUpgradeUpdateAdaptorNwFwPeer1227 = fwUpgradeWaitForAdaptorNwFwUpdateLocal1228 = fwUpgradeWaitForAdaptorNwFwUpdatePeer1229 = fwUpgradeActivateAdaptorNwFwLocal1230 = fwUpgradeActivateAdaptorNwFwPeer1231 = fwUpgradeNicConfigPnuOSLocal1232 = fwUpgradeNicConfigPnuOSPeer1233 = fwUpgradeBmcConfigPnuOS1234 = fwUpgradeSolRedirectEnable1235 = fwUpgradeSerialDebugPnuOSConnect1236 = fwUpgradeBootPnuos1237 = fwUpgradeBootWait1238 = fwUpgradeBiosPostCompletion1239 = fwUpgradeHagPnuOSConnect1240 = fwUpgradePnuOSIdent1241 = fwUpgradePnuOSPolicy1242 = fwUpgradePnuOSCatalog1243 = fwUpgradePnuOSValidate1244 = fwUpgradePnuOSSelfTest1245 = fwUpgradeStorageCtlrImgUpdate1246 = fwUpgradeHbaImgUpdate1247 = fwUpgradeNicImgUpdate1248 = fwUpgradeLocalDiskFwUpdate1249 = fwUpgradePnuOSConfig1250 = fwUpgradePnuOSInventory1251 = fwUpgradeBiosImgUpdate1252 = fwUpgradePnuOSUnloadDrivers1253 = fwUpgradeBmcUnconfigPnuOS1254 = fwUpgradeNicUnconfigPnuOSLocal1255 = fwUpgradeNicUnconfigPnuOSPeer1256 = fwUpgradeSwUnconfigPnuOSLocal1257 = fwUpgradeSwUnconfigPnuOSPeer1258 = fwUpgradeDeassertResetBypass1259 = fwUpgradeHagPnuOSDisconnect1260 = fwUpgradeSerialDebugPnuOSDisconnect1261 = fwUpgradeSolRedirectDisable1262 = fwUpgradeShutdown1263 = adapterResetBegin1264 = adapterResetPreSanitize1265 = adapterResetSanitize1266 = adapterResetDeassertResetBypass1267 = adapterResetPowerCycle1307 = activateAdaptorDeassertResetBypass1386 = fwUpgradeFail1387 = fwUpgradeSuccess1388 = resetIpmiFail1389 = resetIpmiSuccess1390 = adapterResetFail1391 = adapterResetSuccess1468 = associateConfigFlexFlash1469 = associateSyncPowerState1470 = disassociateUnconfigFlexFlash1477 = cimcSessionDeleteBegin1478 = cimcSessionDeleteExecute1483 = cimcSessionDeleteFail1484 = cimcSessionDeleteSuccess1497 = updateBoardControllerBegin1498 = updateBoardControllerPrepareForUpdate1499 = updateBoardControllerServerPowerOff1500 = updateBoardControllerUpdateRequest1501 = updateBoardControllerPollUpdateStatus1502 = updateBoardControllerServerPowerOn1506 = configBoardBegin1507 = configBoardConfigMemoryPolicy1508 = resetMemoryErrorsBegin1509 = resetMemoryErrorsExecute1510 = discoverOobStorageInventory1511 = discoverConfigFlexFlashScrub1520 = associateOobStorageInventory1521 = associateSwConfigServiceInfraLocal1522 = associateSwConfigServiceInfraPeer1523 = associateNicConfigServiceInfraLocal1524 = associateNicConfigServiceInfraPeer1525 = disassociateNicUnconfigServiceInfraLocal1526 = disassociateNicUnconfigServiceInfraPeer1527 = disassociateConfigFlexFlashScrub1528 = createDhcpEntryBegin1529 = createDhcpEntryExecuteLocal1530 = createDhcpEntryExecutePeer1531 = serviceInfraDeployBegin1532 = serviceInfraDeploySwConfigLocal1533 = serviceInfraDeploySwConfigPeer1534 = serviceInfraDeployNicConfigLocal1535 = serviceInfraDeployNicConfigPeer1536 = serviceInfraWithdrawBegin1537 = serviceInfraWithdrawSwUnConfigLocal1538 = serviceInfraWithdrawSwUnConfigPeer1539 = serviceInfraWithdrawNicUnConfigLocal1540 = serviceInfraWithdrawNicUnConfigPeer1541 = configBoardFail1542 = configBoardSuccess1543 = resetMemoryErrorsFail1544 = resetMemoryErrorsSuccess1545 = serviceInfraDeployFail1546 = serviceInfraDeploySuccess1547 = serviceInfraWithdrawFail1548 = serviceInfraWithdrawSuccess1549 = updateBoardControllerFail1550 = updateBoardControllerSuccess1551 = createDhcpEntryFail1552 = createDhcpEntrySuccess1561 = associatePowerOnPreConfig1562 = disassociateResetSecureBootConfig1572 = associateDownloadImages1573 = associateCopyRemote1574 = associateCheckPowerAvailability1575 = associateDeleteCurlDownloadedImages1576 = fwUpgradeDownloadImages1577 = fwUpgradeCopyRemote1578 = fwUpgradeDeleteCurlDownloadedImages1597 = updateAdaptorCheckPowerAvailability1598 = updateAdaptorPowerDeployWait1599 = activateAdaptorCheckPowerAvailability1600 = activateAdaptorPowerDeployWait1602 = associatePowerDeployWait1603 = disassociateCheckPowerAvailability1604 = disassociatePowerDeployWait1605 = fwUpgradeCheckPowerAvailability1606 = fwUpgradePowerDeployWait1614 = discoverUnconfigExtMgmtRules1615 = discoverUnconfigExtMgmtGw1616 = discoverUnconfigCimcVMedia1620 = associateUnconfigExtMgmtRules1621 = associateUnconfigExtMgmtGw1622 = associateUnconfigCimcVMedia1623 = associateGraphicsImageUpdate1624 = associateConfigExtMgmtRules1625 = associateConfigExtMgmtGw1626 = associateConfigCimcVMedia1627 = associateSspUpdateHostPreBoot1628 = disassociateConfigKvmMgmtDefaultSetting1629 = disassociateUnconfigExtMgmtRules1630 = disassociateUnconfigExtMgmtGw1631 = disassociateUnconfigCimcVMedia1632 = decommissionUnconfigExtMgmtRules1633 = decommissionUnconfigExtMgmtGw1634 = fwUpgradeUnconfigExtMgmtRules1635 = fwUpgradeUnconfigExtMgmtGw1636 = fwUpgradeUnconfigCimcVMedia1637 = fwUpgradeGraphicsImageUpdate1638 = flashControllerBegin1639 = flashControllerUpdateFlashLife1653 = flashControllerFail1654 = flashControllerSuccess1669 = enableCimcSecureBootBegin1670 = enableCimcSecureBootUpdateRequest1671 = enableCimcSecureBootPollUpdateStatus1672 = enableCimcSecureBootActivate1673 = enableCimcSecureBootReset1676 = enableCimcSecureBootFail1677 = enableCimcSecureBootSuccess1711 = associateUpdateSspOsSoftware1712 = associateWaitForSspOsUpdateComplete1713 = associatePrepareKeyFile1991 = updateAdaptorBootBegin1992 = updateAdaptorBootCheckPowerAvailability1993 = updateAdaptorBootPowerDeployWait1994 = updateAdaptorBootPowerOn1995 = updateAdaptorBootUpdateRequestLocal1996 = updateAdaptorBootUpdateRequestPeer1997 = updateAdaptorBootPollUpdateStatusLocal1998 = updateAdaptorBootPollUpdateStatusPeer1999 = updateAdaptorBootPowerOff2000 = updateAdaptorBootFail2001 = updateAdaptorBootSuccess2035 = hardPowercycleBegin2036 = hardPowercycleExecute2068 = hardPowercycleFail2069 = hardPowercycleSuccess · Integer32

Cisco Firepower compute:RackUnitFsmStage:name managed object property

cfprComputeRackUnitFsmStageOrder

1.3.6.1.4.1.9.9.826.1.12.54.1.7

Gauge32

Cisco Firepower compute:RackUnitFsmStage:order managed object property

cfprComputeRackUnitFsmStageRetry

1.3.6.1.4.1.9.9.826.1.12.54.1.8

Gauge32

Cisco Firepower compute:RackUnitFsmStage:retry managed object property

cfprComputeRackUnitFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.12.54.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:RackUnitFsmStage:stageStatus managed object property

cfprComputeRackUnitFsmTaskTable

1.3.6.1.4.1.9.9.826.1.12.55

Index: cfprComputeRackUnitFsmTaskInstanceId

Cisco Firepower compute:RackUnitFsmTask managed object table

cfprComputeRackUnitFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.12.55.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackUnitFsmTaskDn

1.3.6.1.4.1.9.9.826.1.12.55.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackUnitFsmTask:dn managed object property

cfprComputeRackUnitFsmTaskRn

1.3.6.1.4.1.9.9.826.1.12.55.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitFsmTask:rn managed object property

cfprComputeRackUnitFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.12.55.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower compute:RackUnitFsmTask:completion managed object property

cfprComputeRackUnitFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.12.55.1.5

CfprComputeRackUnitFsmTaskFlags · BITS

Cisco Firepower compute:RackUnitFsmTask:flags managed object property

cfprComputeRackUnitFsmTaskItem

1.3.6.1.4.1.9.9.826.1.12.55.1.6

CfprComputeRackUnitFsmTaskItem0 = nop819 = discover1064 = offline1263 = adapterReset1528 = createDhcpEntry · Integer32

Cisco Firepower compute:RackUnitFsmTask:item managed object property

cfprComputeRackUnitFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.12.55.1.7

Gauge32

Cisco Firepower compute:RackUnitFsmTask:seqId managed object property

cfprComputeRackUnitMbTempStatsTable

1.3.6.1.4.1.9.9.826.1.12.56

Index: cfprComputeRackUnitMbTempStatsInstanceId

Cisco Firepower compute:RackUnitMbTempStats managed object table

cfprComputeRackUnitMbTempStatsInstanceId

1.3.6.1.4.1.9.9.826.1.12.56.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackUnitMbTempStatsDn

1.3.6.1.4.1.9.9.826.1.12.56.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackUnitMbTempStats:dn managed object property

cfprComputeRackUnitMbTempStatsRn

1.3.6.1.4.1.9.9.826.1.12.56.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitMbTempStats:rn managed object property

cfprComputeRackUnitMbTempStatsAmbientTemp

1.3.6.1.4.1.9.9.826.1.12.56.1.4

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ambientTemp managed object property

cfprComputeRackUnitMbTempStatsAmbientTempAvg

1.3.6.1.4.1.9.9.826.1.12.56.1.5

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ambientTempAvg managed object property

cfprComputeRackUnitMbTempStatsAmbientTempMax

1.3.6.1.4.1.9.9.826.1.12.56.1.6

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ambientTempMax managed object property

cfprComputeRackUnitMbTempStatsAmbientTempMin

1.3.6.1.4.1.9.9.826.1.12.56.1.7

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ambientTempMin managed object property

cfprComputeRackUnitMbTempStatsFrontTemp

1.3.6.1.4.1.9.9.826.1.12.56.1.8

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:frontTemp managed object property

cfprComputeRackUnitMbTempStatsFrontTempAvg

1.3.6.1.4.1.9.9.826.1.12.56.1.9

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:frontTempAvg managed object property

cfprComputeRackUnitMbTempStatsFrontTempMax

1.3.6.1.4.1.9.9.826.1.12.56.1.10

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:frontTempMax managed object property

cfprComputeRackUnitMbTempStatsFrontTempMin

1.3.6.1.4.1.9.9.826.1.12.56.1.11

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:frontTempMin managed object property

cfprComputeRackUnitMbTempStatsIntervals

1.3.6.1.4.1.9.9.826.1.12.56.1.12

Gauge32

Cisco Firepower compute:RackUnitMbTempStats:intervals managed object property

cfprComputeRackUnitMbTempStatsIoh1Temp

1.3.6.1.4.1.9.9.826.1.12.56.1.13

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh1Temp managed object property

cfprComputeRackUnitMbTempStatsIoh1TempAvg

1.3.6.1.4.1.9.9.826.1.12.56.1.14

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh1TempAvg managed object property

cfprComputeRackUnitMbTempStatsIoh1TempMax

1.3.6.1.4.1.9.9.826.1.12.56.1.15

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh1TempMax managed object property

cfprComputeRackUnitMbTempStatsIoh1TempMin

1.3.6.1.4.1.9.9.826.1.12.56.1.16

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh1TempMin managed object property

cfprComputeRackUnitMbTempStatsIoh2Temp

1.3.6.1.4.1.9.9.826.1.12.56.1.17

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh2Temp managed object property

cfprComputeRackUnitMbTempStatsIoh2TempAvg

1.3.6.1.4.1.9.9.826.1.12.56.1.18

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh2TempAvg managed object property

cfprComputeRackUnitMbTempStatsIoh2TempMax

1.3.6.1.4.1.9.9.826.1.12.56.1.19

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh2TempMax managed object property

cfprComputeRackUnitMbTempStatsIoh2TempMin

1.3.6.1.4.1.9.9.826.1.12.56.1.20

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:ioh2TempMin managed object property

cfprComputeRackUnitMbTempStatsRearTemp

1.3.6.1.4.1.9.9.826.1.12.56.1.21

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:rearTemp managed object property

cfprComputeRackUnitMbTempStatsRearTempAvg

1.3.6.1.4.1.9.9.826.1.12.56.1.22

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:rearTempAvg managed object property

cfprComputeRackUnitMbTempStatsRearTempMax

1.3.6.1.4.1.9.9.826.1.12.56.1.23

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:rearTempMax managed object property

cfprComputeRackUnitMbTempStatsRearTempMin

1.3.6.1.4.1.9.9.826.1.12.56.1.24

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStats:rearTempMin managed object property

cfprComputeRackUnitMbTempStatsSuspect

1.3.6.1.4.1.9.9.826.1.12.56.1.25

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:RackUnitMbTempStats:suspect managed object property

cfprComputeRackUnitMbTempStatsThresholded

1.3.6.1.4.1.9.9.826.1.12.56.1.26

CfprComputeRackUnitMbTempStatsThresholded · BITS

Cisco Firepower compute:RackUnitMbTempStats:thresholded managed object property

cfprComputeRackUnitMbTempStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.12.56.1.27

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnitMbTempStats:timeCollected managed object property

cfprComputeRackUnitMbTempStatsUpdate

1.3.6.1.4.1.9.9.826.1.12.56.1.28

Gauge32

Cisco Firepower compute:RackUnitMbTempStats:update managed object property

cfprComputeRackUnitMbTempStatsHistTable

1.3.6.1.4.1.9.9.826.1.12.57

Index: cfprComputeRackUnitMbTempStatsHistInstanceId

Cisco Firepower compute:RackUnitMbTempStatsHist managed object table

cfprComputeRackUnitMbTempStatsHistInstanceId

1.3.6.1.4.1.9.9.826.1.12.57.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRackUnitMbTempStatsHistDn

1.3.6.1.4.1.9.9.826.1.12.57.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RackUnitMbTempStatsHist:dn managed object property

cfprComputeRackUnitMbTempStatsHistRn

1.3.6.1.4.1.9.9.826.1.12.57.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RackUnitMbTempStatsHist:rn managed object property

cfprComputeRackUnitMbTempStatsHistAmbientTemp

1.3.6.1.4.1.9.9.826.1.12.57.1.4

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTemp managed object property

cfprComputeRackUnitMbTempStatsHistAmbientTempAvg

1.3.6.1.4.1.9.9.826.1.12.57.1.5

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTempAvg managed object property

cfprComputeRackUnitMbTempStatsHistAmbientTempMax

1.3.6.1.4.1.9.9.826.1.12.57.1.6

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTempMax managed object property

cfprComputeRackUnitMbTempStatsHistAmbientTempMin

1.3.6.1.4.1.9.9.826.1.12.57.1.7

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ambientTempMin managed object property

cfprComputeRackUnitMbTempStatsHistFrontTemp

1.3.6.1.4.1.9.9.826.1.12.57.1.8

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:frontTemp managed object property

cfprComputeRackUnitMbTempStatsHistFrontTempAvg

1.3.6.1.4.1.9.9.826.1.12.57.1.9

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:frontTempAvg managed object property

cfprComputeRackUnitMbTempStatsHistFrontTempMax

1.3.6.1.4.1.9.9.826.1.12.57.1.10

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:frontTempMax managed object property

cfprComputeRackUnitMbTempStatsHistFrontTempMin

1.3.6.1.4.1.9.9.826.1.12.57.1.11

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:frontTempMin managed object property

cfprComputeRackUnitMbTempStatsHistId

1.3.6.1.4.1.9.9.826.1.12.57.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower compute:RackUnitMbTempStatsHist:id managed object property

cfprComputeRackUnitMbTempStatsHistIoh1Temp

1.3.6.1.4.1.9.9.826.1.12.57.1.13

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1Temp managed object property

cfprComputeRackUnitMbTempStatsHistIoh1TempAvg

1.3.6.1.4.1.9.9.826.1.12.57.1.14

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1TempAvg managed object property

cfprComputeRackUnitMbTempStatsHistIoh1TempMax

1.3.6.1.4.1.9.9.826.1.12.57.1.15

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1TempMax managed object property

cfprComputeRackUnitMbTempStatsHistIoh1TempMin

1.3.6.1.4.1.9.9.826.1.12.57.1.16

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh1TempMin managed object property

cfprComputeRackUnitMbTempStatsHistIoh2Temp

1.3.6.1.4.1.9.9.826.1.12.57.1.17

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2Temp managed object property

cfprComputeRackUnitMbTempStatsHistIoh2TempAvg

1.3.6.1.4.1.9.9.826.1.12.57.1.18

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2TempAvg managed object property

cfprComputeRackUnitMbTempStatsHistIoh2TempMax

1.3.6.1.4.1.9.9.826.1.12.57.1.19

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2TempMax managed object property

cfprComputeRackUnitMbTempStatsHistIoh2TempMin

1.3.6.1.4.1.9.9.826.1.12.57.1.20

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:ioh2TempMin managed object property

cfprComputeRackUnitMbTempStatsHistMostRecent

1.3.6.1.4.1.9.9.826.1.12.57.1.21

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:mostRecent managed object property

cfprComputeRackUnitMbTempStatsHistRearTemp

1.3.6.1.4.1.9.9.826.1.12.57.1.22

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:rearTemp managed object property

cfprComputeRackUnitMbTempStatsHistRearTempAvg

1.3.6.1.4.1.9.9.826.1.12.57.1.23

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:rearTempAvg managed object property

cfprComputeRackUnitMbTempStatsHistRearTempMax

1.3.6.1.4.1.9.9.826.1.12.57.1.24

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:rearTempMax managed object property

cfprComputeRackUnitMbTempStatsHistRearTempMin

1.3.6.1.4.1.9.9.826.1.12.57.1.25

INTEGER · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:rearTempMin managed object property

cfprComputeRackUnitMbTempStatsHistSuspect

1.3.6.1.4.1.9.9.826.1.12.57.1.26

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower compute:RackUnitMbTempStatsHist:suspect managed object property

cfprComputeRackUnitMbTempStatsHistThresholded

1.3.6.1.4.1.9.9.826.1.12.57.1.27

CfprComputeRackUnitMbTempStatsHistThresholded · BITS

Cisco Firepower compute:RackUnitMbTempStatsHist:thresholded managed object property

cfprComputeRackUnitMbTempStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.1.12.57.1.28

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:RackUnitMbTempStatsHist:timeCollected managed object property

cfprComputeRtcBatteryTable

1.3.6.1.4.1.9.9.826.1.12.58

Index: cfprComputeRtcBatteryInstanceId

Cisco Firepower compute:RtcBattery managed object table

cfprComputeRtcBatteryInstanceId

1.3.6.1.4.1.9.9.826.1.12.58.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeRtcBatteryDn

1.3.6.1.4.1.9.9.826.1.12.58.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:RtcBattery:dn managed object property

cfprComputeRtcBatteryRn

1.3.6.1.4.1.9.9.826.1.12.58.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:rn managed object property

cfprComputeRtcBatteryId

1.3.6.1.4.1.9.9.826.1.12.58.1.4

Gauge32

Cisco Firepower compute:RtcBattery:id managed object property

cfprComputeRtcBatteryLocationDn

1.3.6.1.4.1.9.9.826.1.12.58.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:locationDn managed object property

cfprComputeRtcBatteryModel

1.3.6.1.4.1.9.9.826.1.12.58.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:model managed object property

cfprComputeRtcBatteryOperQualifierReason

1.3.6.1.4.1.9.9.826.1.12.58.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:operQualifierReason managed object property

cfprComputeRtcBatteryOperState

1.3.6.1.4.1.9.9.826.1.12.58.1.8

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:RtcBattery:operState managed object property

cfprComputeRtcBatteryOperability

1.3.6.1.4.1.9.9.826.1.12.58.1.9

CfprEquipmentOperability0 = unknown1 = operable2 = inoperable3 = degraded4 = poweredOff5 = powerProblem6 = removed7 = voltageProblem8 = thermalProblem9 = performanceProblem10 = accessibilityProblem11 = identityUnestablishable12 = biosPostTimeout13 = disabled14 = malformedFru15 = fanspeedIncreased16 = firmwareUpgrading51 = fabricConnProblem52 = fabricUnsupportedConn81 = config82 = equipmentProblem83 = decomissioning84 = chassisLimitExceeded100 = notSupported101 = discovery102 = discoveryFailed103 = identify104 = postFailure105 = upgradeProblem106 = peerCommProblem107 = autoUpgrade108 = linkActivateBlocked · Integer32

Cisco Firepower compute:RtcBattery:operability managed object property

cfprComputeRtcBatteryPerf

1.3.6.1.4.1.9.9.826.1.12.58.1.10

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:RtcBattery:perf managed object property

cfprComputeRtcBatteryPower

1.3.6.1.4.1.9.9.826.1.12.58.1.11

CfprEquipmentPowerState0 = unknown1 = on2 = test3 = off4 = online5 = offline6 = offduty7 = degraded8 = powerSave9 = error10 = ok11 = failed12 = oirFailed13 = oirInvalid100 = notSupported · Integer32

Cisco Firepower compute:RtcBattery:power managed object property

cfprComputeRtcBatteryPresence

1.3.6.1.4.1.9.9.826.1.12.58.1.12

CfprEquipmentPresence0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized100 = notSupported · Integer32

Cisco Firepower compute:RtcBattery:presence managed object property

cfprComputeRtcBatteryRevision

1.3.6.1.4.1.9.9.826.1.12.58.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:revision managed object property

cfprComputeRtcBatterySerial

1.3.6.1.4.1.9.9.826.1.12.58.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:serial managed object property

cfprComputeRtcBatteryThermal

1.3.6.1.4.1.9.9.826.1.12.58.1.15

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:RtcBattery:thermal managed object property

cfprComputeRtcBatteryVendor

1.3.6.1.4.1.9.9.826.1.12.58.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:RtcBattery:vendor managed object property

cfprComputeRtcBatteryVoltage

1.3.6.1.4.1.9.9.826.1.12.58.1.17

CfprEquipmentSensorThresholdStatus0 = unknown1 = ok2 = upperNonRecoverable3 = upperCritical4 = upperNonCritical5 = lowerNonCritical6 = lowerCritical7 = lowerNonRecoverable100 = notSupported · Integer32

Cisco Firepower compute:RtcBattery:voltage managed object property

cfprComputeScrubPolicyTable

1.3.6.1.4.1.9.9.826.1.12.59

Index: cfprComputeScrubPolicyInstanceId

Cisco Firepower compute:ScrubPolicy managed object table

cfprComputeScrubPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.59.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeScrubPolicyDn

1.3.6.1.4.1.9.9.826.1.12.59.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ScrubPolicy:dn managed object property

cfprComputeScrubPolicyRn

1.3.6.1.4.1.9.9.826.1.12.59.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ScrubPolicy:rn managed object property

cfprComputeScrubPolicyBiosSettingsScrub

1.3.6.1.4.1.9.9.826.1.12.59.1.4

CfprComputeScrubAction0 = no1 = yes · Integer32

Cisco Firepower compute:ScrubPolicy:biosSettingsScrub managed object property

cfprComputeScrubPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.59.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ScrubPolicy:descr managed object property

cfprComputeScrubPolicyDiskScrub

1.3.6.1.4.1.9.9.826.1.12.59.1.6

CfprComputeScrubAction0 = no1 = yes · Integer32

Cisco Firepower compute:ScrubPolicy:diskScrub managed object property

cfprComputeScrubPolicyFlexFlashScrub

1.3.6.1.4.1.9.9.826.1.12.59.1.7

CfprComputeScrubAction0 = no1 = yes · Integer32

Cisco Firepower compute:ScrubPolicy:flexFlashScrub managed object property

cfprComputeScrubPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.59.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ScrubPolicy:intId managed object property

cfprComputeScrubPolicyName

1.3.6.1.4.1.9.9.826.1.12.59.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ScrubPolicy:name managed object property

cfprComputeScrubPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.59.1.10

Gauge32

Cisco Firepower compute:ScrubPolicy:policyLevel managed object property

cfprComputeScrubPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.59.1.11

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:ScrubPolicy:policyOwner managed object property

cfprComputeServerDiscPolicyTable

1.3.6.1.4.1.9.9.826.1.12.60

Index: cfprComputeServerDiscPolicyInstanceId

Cisco Firepower compute:ServerDiscPolicy managed object table

cfprComputeServerDiscPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.60.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeServerDiscPolicyDn

1.3.6.1.4.1.9.9.826.1.12.60.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ServerDiscPolicy:dn managed object property

cfprComputeServerDiscPolicyRn

1.3.6.1.4.1.9.9.826.1.12.60.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:rn managed object property

cfprComputeServerDiscPolicyAction

1.3.6.1.4.1.9.9.826.1.12.60.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:action managed object property

cfprComputeServerDiscPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.60.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:descr managed object property

cfprComputeServerDiscPolicyFsmDescr

1.3.6.1.4.1.9.9.826.1.12.60.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:fsmDescr managed object property

cfprComputeServerDiscPolicyFsmPrev

1.3.6.1.4.1.9.9.826.1.12.60.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:fsmPrev managed object property

cfprComputeServerDiscPolicyFsmProgr

1.3.6.1.4.1.9.9.826.1.12.60.1.8

Gauge32

Cisco Firepower compute:ServerDiscPolicy:fsmProgr managed object property

cfprComputeServerDiscPolicyFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.12.60.1.9

Gauge32

Cisco Firepower compute:ServerDiscPolicy:fsmRmtInvErrCode managed object property

cfprComputeServerDiscPolicyFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.12.60.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:fsmRmtInvErrDescr managed object property

cfprComputeServerDiscPolicyFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.12.60.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:ServerDiscPolicy:fsmRmtInvRslt managed object property

cfprComputeServerDiscPolicyFsmStageDescr

1.3.6.1.4.1.9.9.826.1.12.60.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:fsmStageDescr managed object property

cfprComputeServerDiscPolicyFsmStamp

1.3.6.1.4.1.9.9.826.1.12.60.1.13

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:ServerDiscPolicy:fsmStamp managed object property

cfprComputeServerDiscPolicyFsmStatus

1.3.6.1.4.1.9.9.826.1.12.60.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:fsmStatus managed object property

cfprComputeServerDiscPolicyFsmTry

1.3.6.1.4.1.9.9.826.1.12.60.1.15

Gauge32

Cisco Firepower compute:ServerDiscPolicy:fsmTry managed object property

cfprComputeServerDiscPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.60.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:intId managed object property

cfprComputeServerDiscPolicyName

1.3.6.1.4.1.9.9.826.1.12.60.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:name managed object property

cfprComputeServerDiscPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.60.1.18

Gauge32

Cisco Firepower compute:ServerDiscPolicy:policyLevel managed object property

cfprComputeServerDiscPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.60.1.19

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:ServerDiscPolicy:policyOwner managed object property

cfprComputeServerDiscPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.60.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:qualifier managed object property

cfprComputeServerDiscPolicyScrubPolicyName

1.3.6.1.4.1.9.9.826.1.12.60.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicy:scrubPolicyName managed object property

cfprComputeServerDiscPolicyFsmTable

1.3.6.1.4.1.9.9.826.1.12.61

Index: cfprComputeServerDiscPolicyFsmInstanceId

Cisco Firepower compute:ServerDiscPolicyFsm managed object table

cfprComputeServerDiscPolicyFsmInstanceId

1.3.6.1.4.1.9.9.826.1.12.61.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeServerDiscPolicyFsmDn

1.3.6.1.4.1.9.9.826.1.12.61.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ServerDiscPolicyFsm:dn managed object property

cfprComputeServerDiscPolicyFsmRn

1.3.6.1.4.1.9.9.826.1.12.61.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicyFsm:rn managed object property

cfprComputeServerDiscPolicyFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.12.61.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:ServerDiscPolicyFsm:completionTime managed object property

cfprComputeServerDiscPolicyFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.12.61.1.5

CfprComputeServerDiscPolicyFsmCurrentFsm0 = nop1329 = resolveScrubPolicy · Integer32

Cisco Firepower compute:ServerDiscPolicyFsm:currentFsm managed object property

cfprComputeServerDiscPolicyFsmDescrData

1.3.6.1.4.1.9.9.826.1.12.61.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicyFsm:descr managed object property

cfprComputeServerDiscPolicyFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.12.61.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:ServerDiscPolicyFsm:fsmStatus managed object property

cfprComputeServerDiscPolicyFsmProgress

1.3.6.1.4.1.9.9.826.1.12.61.1.8

Gauge32

Cisco Firepower compute:ServerDiscPolicyFsm:progress managed object property

cfprComputeServerDiscPolicyFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.12.61.1.9

Gauge32

Cisco Firepower compute:ServerDiscPolicyFsm:rmtErrCode managed object property

cfprComputeServerDiscPolicyFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.12.61.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicyFsm:rmtErrDescr managed object property

cfprComputeServerDiscPolicyFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.12.61.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower compute:ServerDiscPolicyFsm:rmtRslt managed object property

cfprComputeServerDiscPolicyFsmStageTable

1.3.6.1.4.1.9.9.826.1.12.62

Index: cfprComputeServerDiscPolicyFsmStageInstanceId

Cisco Firepower compute:ServerDiscPolicyFsmStage managed object table

cfprComputeServerDiscPolicyFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.12.62.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeServerDiscPolicyFsmStageDn

1.3.6.1.4.1.9.9.826.1.12.62.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ServerDiscPolicyFsmStage:dn managed object property

cfprComputeServerDiscPolicyFsmStageRn

1.3.6.1.4.1.9.9.826.1.12.62.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicyFsmStage:rn managed object property

cfprComputeServerDiscPolicyFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.12.62.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicyFsmStage:descr managed object property

cfprComputeServerDiscPolicyFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.12.62.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower compute:ServerDiscPolicyFsmStage:lastUpdateTime managed object property

cfprComputeServerDiscPolicyFsmStageName

1.3.6.1.4.1.9.9.826.1.12.62.1.6

CfprComputeServerDiscPolicyFsmStageName0 = nop1329 = resolveScrubPolicyBegin1330 = resolveScrubPolicyResolve1392 = resolveScrubPolicyFail1393 = resolveScrubPolicySuccess · Integer32

Cisco Firepower compute:ServerDiscPolicyFsmStage:name managed object property

cfprComputeServerDiscPolicyFsmStageOrder

1.3.6.1.4.1.9.9.826.1.12.62.1.7

Gauge32

Cisco Firepower compute:ServerDiscPolicyFsmStage:order managed object property

cfprComputeServerDiscPolicyFsmStageRetry

1.3.6.1.4.1.9.9.826.1.12.62.1.8

Gauge32

Cisco Firepower compute:ServerDiscPolicyFsmStage:retry managed object property

cfprComputeServerDiscPolicyFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.12.62.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower compute:ServerDiscPolicyFsmStage:stageStatus managed object property

cfprComputeServerDiscPolicyFsmTaskTable

1.3.6.1.4.1.9.9.826.1.12.63

Index: cfprComputeServerDiscPolicyFsmTaskInstanceId

Cisco Firepower compute:ServerDiscPolicyFsmTask managed object table

cfprComputeServerDiscPolicyFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.12.63.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeServerDiscPolicyFsmTaskDn

1.3.6.1.4.1.9.9.826.1.12.63.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ServerDiscPolicyFsmTask:dn managed object property

cfprComputeServerDiscPolicyFsmTaskRn

1.3.6.1.4.1.9.9.826.1.12.63.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerDiscPolicyFsmTask:rn managed object property

cfprComputeServerDiscPolicyFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.12.63.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower compute:ServerDiscPolicyFsmTask:completion managed object property

cfprComputeServerDiscPolicyFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.12.63.1.5

CfprFsmFlags · BITS

Cisco Firepower compute:ServerDiscPolicyFsmTask:flags managed object property

cfprComputeServerDiscPolicyFsmTaskItem

1.3.6.1.4.1.9.9.826.1.12.63.1.6

CfprComputeServerDiscPolicyFsmTaskItem0 = nop1329 = resolveScrubPolicy · Integer32

Cisco Firepower compute:ServerDiscPolicyFsmTask:item managed object property

cfprComputeServerDiscPolicyFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.12.63.1.7

Gauge32

Cisco Firepower compute:ServerDiscPolicyFsmTask:seqId managed object property

cfprComputeServerMgmtPolicyTable

1.3.6.1.4.1.9.9.826.1.12.64

Index: cfprComputeServerMgmtPolicyInstanceId

Cisco Firepower compute:ServerMgmtPolicy managed object table

cfprComputeServerMgmtPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.12.64.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeServerMgmtPolicyDn

1.3.6.1.4.1.9.9.826.1.12.64.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:ServerMgmtPolicy:dn managed object property

cfprComputeServerMgmtPolicyRn

1.3.6.1.4.1.9.9.826.1.12.64.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerMgmtPolicy:rn managed object property

cfprComputeServerMgmtPolicyAction

1.3.6.1.4.1.9.9.826.1.12.64.1.4

CfprComputeServerMgmtDiscAction0 = autoAcknowledged1 = userAcknowledged · Integer32

Cisco Firepower compute:ServerMgmtPolicy:action managed object property

cfprComputeServerMgmtPolicyDescr

1.3.6.1.4.1.9.9.826.1.12.64.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerMgmtPolicy:descr managed object property

cfprComputeServerMgmtPolicyIntId

1.3.6.1.4.1.9.9.826.1.12.64.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerMgmtPolicy:intId managed object property

cfprComputeServerMgmtPolicyName

1.3.6.1.4.1.9.9.826.1.12.64.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerMgmtPolicy:name managed object property

cfprComputeServerMgmtPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.12.64.1.8

Gauge32

Cisco Firepower compute:ServerMgmtPolicy:policyLevel managed object property

cfprComputeServerMgmtPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.12.64.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower compute:ServerMgmtPolicy:policyOwner managed object property

cfprComputeServerMgmtPolicyQualifier

1.3.6.1.4.1.9.9.826.1.12.64.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:ServerMgmtPolicy:qualifier managed object property

cfprComputeSlotQualTable

1.3.6.1.4.1.9.9.826.1.12.65

Index: cfprComputeSlotQualInstanceId

Cisco Firepower compute:SlotQual managed object table

cfprComputeSlotQualInstanceId

1.3.6.1.4.1.9.9.826.1.12.65.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprComputeSlotQualDn

1.3.6.1.4.1.9.9.826.1.12.65.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower compute:SlotQual:dn managed object property

cfprComputeSlotQualRn

1.3.6.1.4.1.9.9.826.1.12.65.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower compute:SlotQual:rn managed object property

cfprComputeSlotQualMaxId

1.3.6.1.4.1.9.9.826.1.12.65.1.4

CfprComputeSlotQualMaxId (1..8) · Gauge32

Cisco Firepower compute:SlotQual:maxId managed object property

cfprComputeSlotQualMinId

1.3.6.1.4.1.9.9.826.1.12.65.1.5

CfprComputeSlotQualMinId (1..8) · Gauge32

Cisco Firepower compute:SlotQual:minId managed object property

↑ To TOC