EZ5 MIB Catalog

CISCO-FIREPOWER-FABRIC-MIB

2024-05-16

MIB representation of the Cisco Firepower FABRIC management information model package

Download CISCO-FIREPOWER-FABRIC-MIB.txt Open CISCO-FIREPOWER-FABRIC-MIB.txt in a new tab

TABLES (108)

Tables (108)

NameOID
cfprFabricBHVlanTable1.3.6.1.4.1.9.9.826.1.26.1
cfprFabricBreakoutTable1.3.6.1.4.1.9.9.826.1.26.2
cfprFabricCablingTable1.3.6.1.4.1.9.9.826.1.26.3
cfprFabricCablingSwTable1.3.6.1.4.1.9.9.826.1.26.4
cfprFabricCdpLinkPolicyTable1.3.6.1.4.1.9.9.826.1.26.5
cfprFabricChangedObjectRefTable1.3.6.1.4.1.9.9.826.1.26.6
cfprFabricChassisEpTable1.3.6.1.4.1.9.9.826.1.26.7
cfprFabricComputePhEpTable1.3.6.1.4.1.9.9.826.1.26.8
cfprFabricComputeSlotEpTable1.3.6.1.4.1.9.9.826.1.26.9
cfprFabricComputeSlotEpFsmTable1.3.6.1.4.1.9.9.826.1.26.10
cfprFabricComputeSlotEpFsmStageTable1.3.6.1.4.1.9.9.826.1.26.11
cfprFabricComputeSlotEpFsmTaskTable1.3.6.1.4.1.9.9.826.1.26.12
cfprFabricDceSrvTable1.3.6.1.4.1.9.9.826.1.26.13
cfprFabricDceSwSrvTable1.3.6.1.4.1.9.9.826.1.26.14
cfprFabricDceSwSrvEpTable1.3.6.1.4.1.9.9.826.1.26.15
cfprFabricDceSwSrvPcTable1.3.6.1.4.1.9.9.826.1.26.16
cfprFabricDceSwSrvPcEpTable1.3.6.1.4.1.9.9.826.1.26.17
cfprFabricEpTable1.3.6.1.4.1.9.9.826.1.26.18
cfprFabricEpMgrTable1.3.6.1.4.1.9.9.826.1.26.19
cfprFabricEpMgrFsmTable1.3.6.1.4.1.9.9.826.1.26.20
cfprFabricEpMgrFsmStageTable1.3.6.1.4.1.9.9.826.1.26.21
cfprFabricEpMgrFsmTaskTable1.3.6.1.4.1.9.9.826.1.26.22
cfprFabricEthEstcTable1.3.6.1.4.1.9.9.826.1.26.23
cfprFabricEthEstcCloudTable1.3.6.1.4.1.9.9.826.1.26.24
cfprFabricEthEstcEpTable1.3.6.1.4.1.9.9.826.1.26.25
cfprFabricEthEstcPcTable1.3.6.1.4.1.9.9.826.1.26.26
cfprFabricEthEstcPcEpTable1.3.6.1.4.1.9.9.826.1.26.27
cfprFabricEthLanTable1.3.6.1.4.1.9.9.826.1.26.29
cfprFabricEthLanEpTable1.3.6.1.4.1.9.9.826.1.26.30
cfprFabricEthLanPcTable1.3.6.1.4.1.9.9.826.1.26.32
cfprFabricEthLanPcEpTable1.3.6.1.4.1.9.9.826.1.26.33
cfprFabricEthLinkProfileTable1.3.6.1.4.1.9.9.826.1.26.34
cfprFabricEthMonTable1.3.6.1.4.1.9.9.826.1.26.35
cfprFabricEthMonDestEpTable1.3.6.1.4.1.9.9.826.1.26.36
cfprFabricEthMonFiltEpTable1.3.6.1.4.1.9.9.826.1.26.37
cfprFabricEthMonFiltRefTable1.3.6.1.4.1.9.9.826.1.26.38
cfprFabricEthMonLanTable1.3.6.1.4.1.9.9.826.1.26.39
cfprFabricEthMonSrcEpTable1.3.6.1.4.1.9.9.826.1.26.40
cfprFabricEthMonSrcRefTable1.3.6.1.4.1.9.9.826.1.26.41
cfprFabricEthTargetEpTable1.3.6.1.4.1.9.9.826.1.26.42
cfprFabricEthVlanPcTable1.3.6.1.4.1.9.9.826.1.26.43
cfprFabricEthVlanPortEpTable1.3.6.1.4.1.9.9.826.1.26.44
cfprFabricFcSanTable1.3.6.1.4.1.9.9.826.1.26.55
cfprFabricFcSanEpTable1.3.6.1.4.1.9.9.826.1.26.56
cfprFabricFcSanPcTable1.3.6.1.4.1.9.9.826.1.26.57
cfprFabricFcSanPcEpTable1.3.6.1.4.1.9.9.826.1.26.58
cfprFabricFcVsanPcTable1.3.6.1.4.1.9.9.826.1.26.59
cfprFabricFcVsanPortEpTable1.3.6.1.4.1.9.9.826.1.26.60
cfprFabricFcoeSanEpTable1.3.6.1.4.1.9.9.826.1.26.62
cfprFabricFcoeSanPcTable1.3.6.1.4.1.9.9.826.1.26.63
cfprFabricFcoeSanPcEpTable1.3.6.1.4.1.9.9.826.1.26.64
cfprFabricFcoeVsanPcTable1.3.6.1.4.1.9.9.826.1.26.65
cfprFabricFcoeVsanPortEpTable1.3.6.1.4.1.9.9.826.1.26.66
cfprFabricIfTable1.3.6.1.4.1.9.9.826.1.26.69
cfprFabricLacpPolicyTable1.3.6.1.4.1.9.9.826.1.26.70
cfprFabricLanAccessMgrTable1.3.6.1.4.1.9.9.826.1.26.71
cfprFabricLanCloudTable1.3.6.1.4.1.9.9.826.1.26.72
cfprFabricLanCloudFsmTable1.3.6.1.4.1.9.9.826.1.26.73
cfprFabricLanCloudFsmStageTable1.3.6.1.4.1.9.9.826.1.26.74
cfprFabricLanCloudFsmTaskTable1.3.6.1.4.1.9.9.826.1.26.75
cfprFabricLanMonCloudTable1.3.6.1.4.1.9.9.826.1.26.76
cfprFabricLanPinGroupTable1.3.6.1.4.1.9.9.826.1.26.77
cfprFabricLanPinTargetTable1.3.6.1.4.1.9.9.826.1.26.78
cfprFabricLastAckedSlotTable1.3.6.1.4.1.9.9.826.1.26.79
cfprFabricLocaleTable1.3.6.1.4.1.9.9.826.1.26.80
cfprFabricMulticastPolicyTable1.3.6.1.4.1.9.9.826.1.26.81
cfprFabricNetGroupTable1.3.6.1.4.1.9.9.826.1.26.82
cfprFabricOrgVlanPolicyTable1.3.6.1.4.1.9.9.826.1.26.93
cfprFabricPathTable1.3.6.1.4.1.9.9.826.1.26.94
cfprFabricPathConnTable1.3.6.1.4.1.9.9.826.1.26.95
cfprFabricPathEpTable1.3.6.1.4.1.9.9.826.1.26.96
cfprFabricPoolableVlanTable1.3.6.1.4.1.9.9.826.1.26.97
cfprFabricPooledVlanTable1.3.6.1.4.1.9.9.826.1.26.98
cfprFabricSanCloudTable1.3.6.1.4.1.9.9.826.1.26.99
cfprFabricSanCloudFsmTable1.3.6.1.4.1.9.9.826.1.26.100
cfprFabricSanCloudFsmStageTable1.3.6.1.4.1.9.9.826.1.26.101
cfprFabricSanCloudFsmTaskTable1.3.6.1.4.1.9.9.826.1.26.102
cfprFabricSanPinGroupTable1.3.6.1.4.1.9.9.826.1.26.104
cfprFabricSanPinTargetTable1.3.6.1.4.1.9.9.826.1.26.105
cfprFabricSubGroupTable1.3.6.1.4.1.9.9.826.1.26.106
cfprFabricSwChPhEpTable1.3.6.1.4.1.9.9.826.1.26.107
cfprFabricSwSubGroupTable1.3.6.1.4.1.9.9.826.1.26.108
cfprFabricUdldLinkPolicyTable1.3.6.1.4.1.9.9.826.1.26.109
cfprFabricUdldPolicyTable1.3.6.1.4.1.9.9.826.1.26.110
cfprFabricVConTable1.3.6.1.4.1.9.9.826.1.26.111
cfprFabricVConProfileTable1.3.6.1.4.1.9.9.826.1.26.112
cfprFabricVlanTable1.3.6.1.4.1.9.9.826.1.26.113
cfprFabricVlanEpTable1.3.6.1.4.1.9.9.826.1.26.114
cfprFabricVlanGroupReqTable1.3.6.1.4.1.9.9.826.1.26.115
cfprFabricVlanPermitTable1.3.6.1.4.1.9.9.826.1.26.116
cfprFabricVlanReqTable1.3.6.1.4.1.9.9.826.1.26.117
cfprFabricVnetEpSyncEpTable1.3.6.1.4.1.9.9.826.1.26.118
cfprFabricVnetEpSyncEpFsmTable1.3.6.1.4.1.9.9.826.1.26.119
cfprFabricVnetEpSyncEpFsmStageTable1.3.6.1.4.1.9.9.826.1.26.120
cfprFabricVnetEpSyncEpFsmTaskTable1.3.6.1.4.1.9.9.826.1.26.121
cfprFabricVsanTable1.3.6.1.4.1.9.9.826.1.26.122
cfprFabricVsanEpTable1.3.6.1.4.1.9.9.826.1.26.123
cfprFabricVsanMembershipTable1.3.6.1.4.1.9.9.826.1.26.124
cfprFabricZoneIdUniverseTable1.3.6.1.4.1.9.9.826.1.26.125
cfprFabricSspEthMonTable1.3.6.1.4.1.9.9.826.1.26.126
cfprFabricSspEthMonFilterEpTable1.3.6.1.4.1.9.9.826.1.26.127
cfprFabricSspEthMonSrcAppEpTable1.3.6.1.4.1.9.9.826.1.26.128
cfprFabricSspEthMonSrcAppLinksEpTable1.3.6.1.4.1.9.9.826.1.26.129
cfprFabricSspEthMonSrcPhyAggrEpTable1.3.6.1.4.1.9.9.826.1.26.130
cfprFabricSspEthMonSrcPhyEpTable1.3.6.1.4.1.9.9.826.1.26.131
cfprFabricSspLanMonCloudTable1.3.6.1.4.1.9.9.826.1.26.132
cfprFabricInnerVlanMgrTable1.3.6.1.4.1.9.9.826.1.26.133
cfprFabricSubIfTable1.3.6.1.4.1.9.9.826.1.26.134

END OF TOC

Table details

cfprFabricBHVlanTable

1.3.6.1.4.1.9.9.826.1.26.1

Index: cfprFabricBHVlanInstanceId

Cisco Firepower fabric:BHVlan managed object table

cfprFabricBHVlanInstanceId

1.3.6.1.4.1.9.9.826.1.26.1.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricBHVlanDn

1.3.6.1.4.1.9.9.826.1.26.1.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:BHVlan:dn managed object property

cfprFabricBHVlanRn

1.3.6.1.4.1.9.9.826.1.26.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:BHVlan:rn managed object property

cfprFabricBHVlanAssocPrimaryVlanState

1.3.6.1.4.1.9.9.826.1.26.1.1.4

CfprFabricVlanAssocPrimaryVlanState1 = ok2 = isEmpty3 = doesNotExists4 = isNotPrimaryType5 = isInErrorState · Integer32

Cisco Firepower fabric:BHVlan:assocPrimaryVlanState managed object property

cfprFabricBHVlanAssocPrimaryVlanSwitchId

1.3.6.1.4.1.9.9.826.1.26.1.1.5

CfprFabricAVlanAssocPrimaryVlanSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:BHVlan:assocPrimaryVlanSwitchId managed object property

cfprFabricBHVlanEpDn

1.3.6.1.4.1.9.9.826.1.26.1.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:BHVlan:epDn managed object property

cfprFabricBHVlanId

1.3.6.1.4.1.9.9.826.1.26.1.1.7

Gauge32

Cisco Firepower fabric:BHVlan:id managed object property

cfprFabricBHVlanIfRole

1.3.6.1.4.1.9.9.826.1.26.1.1.8

CfprFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:BHVlan:ifRole managed object property

cfprFabricBHVlanIfType

1.3.6.1.4.1.9.9.826.1.26.1.1.9

CfprNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:BHVlan:ifType managed object property

cfprFabricBHVlanLocale

1.3.6.1.4.1.9.9.826.1.26.1.1.10

CfprFabricVnetEpLocale · BITS

Cisco Firepower fabric:BHVlan:locale managed object property

cfprFabricBHVlanName

1.3.6.1.4.1.9.9.826.1.26.1.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:BHVlan:name managed object property

cfprFabricBHVlanOperState

1.3.6.1.4.1.9.9.826.1.26.1.1.12

CfprFabricVlanOperState1 = ok2 = errorMisconfigured · Integer32

Cisco Firepower fabric:BHVlan:operState managed object property

cfprFabricBHVlanOverlapStateForA

1.3.6.1.4.1.9.9.826.1.26.1.1.13

CfprFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower fabric:BHVlan:overlapStateForA managed object property

cfprFabricBHVlanOverlapStateForB

1.3.6.1.4.1.9.9.826.1.26.1.1.14

CfprFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower fabric:BHVlan:overlapStateForB managed object property

cfprFabricBHVlanPeerDn

1.3.6.1.4.1.9.9.826.1.26.1.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:BHVlan:peerDn managed object property

cfprFabricBHVlanPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.1.1.16

CfprFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:BHVlan:policyOwner managed object property

cfprFabricBHVlanPubNwDn

1.3.6.1.4.1.9.9.826.1.26.1.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:BHVlan:pubNwDn managed object property

cfprFabricBHVlanPubNwId

1.3.6.1.4.1.9.9.826.1.26.1.1.18

Gauge32

Cisco Firepower fabric:BHVlan:pubNwId managed object property

cfprFabricBHVlanPubNwName

1.3.6.1.4.1.9.9.826.1.26.1.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:BHVlan:pubNwName managed object property

cfprFabricBHVlanSharing

1.3.6.1.4.1.9.9.826.1.26.1.1.20

CfprFabricAVlanSharing0 = none1 = primary2 = isolated3 = community · Integer32

Cisco Firepower fabric:BHVlan:sharing managed object property

cfprFabricBHVlanSwitchId

1.3.6.1.4.1.9.9.826.1.26.1.1.21

CfprFabricBHVlanSwitchId0 = none1 = a2 = b3 = dual · Integer32

Cisco Firepower fabric:BHVlan:switchId managed object property

cfprFabricBHVlanTransport

1.3.6.1.4.1.9.9.826.1.26.1.1.22

CfprFabricAVlanTransport · BITS

Cisco Firepower fabric:BHVlan:transport managed object property

cfprFabricBHVlanType

1.3.6.1.4.1.9.9.826.1.26.1.1.23

CfprFabricAVlanType · BITS

Cisco Firepower fabric:BHVlan:type managed object property

cfprFabricBreakoutTable

1.3.6.1.4.1.9.9.826.1.26.2

Index: cfprFabricBreakoutInstanceId

Cisco Firepower fabric:Breakout managed object table

cfprFabricBreakoutInstanceId

1.3.6.1.4.1.9.9.826.1.26.2.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricBreakoutDn

1.3.6.1.4.1.9.9.826.1.26.2.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Breakout:dn managed object property

cfprFabricBreakoutRn

1.3.6.1.4.1.9.9.826.1.26.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Breakout:rn managed object property

cfprFabricBreakoutBreakoutType

1.3.6.1.4.1.9.9.826.1.26.2.1.4

CfprFabricBreakoutType0 = unknown1 = n10g4x · Integer32

Cisco Firepower fabric:Breakout:breakoutType managed object property

cfprFabricBreakoutPortId

1.3.6.1.4.1.9.9.826.1.26.2.1.5

CfprFabricBreakoutPortId (1..4) · Gauge32

Cisco Firepower fabric:Breakout:portId managed object property

cfprFabricBreakoutSlotId

1.3.6.1.4.1.9.9.826.1.26.2.1.6

CfprFabricBreakoutSlotId (2..3) · Gauge32

Cisco Firepower fabric:Breakout:slotId managed object property

cfprFabricCablingTable

1.3.6.1.4.1.9.9.826.1.26.3

Index: cfprFabricCablingInstanceId

Cisco Firepower fabric:Cabling managed object table

cfprFabricCablingInstanceId

1.3.6.1.4.1.9.9.826.1.26.3.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricCablingDn

1.3.6.1.4.1.9.9.826.1.26.3.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Cabling:dn managed object property

cfprFabricCablingRn

1.3.6.1.4.1.9.9.826.1.26.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Cabling:rn managed object property

cfprFabricCablingSwTable

1.3.6.1.4.1.9.9.826.1.26.4

Index: cfprFabricCablingSwInstanceId

Cisco Firepower fabric:CablingSw managed object table

cfprFabricCablingSwInstanceId

1.3.6.1.4.1.9.9.826.1.26.4.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricCablingSwDn

1.3.6.1.4.1.9.9.826.1.26.4.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:CablingSw:dn managed object property

cfprFabricCablingSwRn

1.3.6.1.4.1.9.9.826.1.26.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:CablingSw:rn managed object property

cfprFabricCablingSwId

1.3.6.1.4.1.9.9.826.1.26.4.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:CablingSw:id managed object property

cfprFabricCablingSwLocale

1.3.6.1.4.1.9.9.826.1.26.4.1.5

CfprFabricExternalLocale · BITS

Cisco Firepower fabric:CablingSw:locale managed object property

cfprFabricCablingSwName

1.3.6.1.4.1.9.9.826.1.26.4.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:CablingSw:name managed object property

cfprFabricCablingSwTransport

1.3.6.1.4.1.9.9.826.1.26.4.1.7

CfprNetworkTransport · BITS

Cisco Firepower fabric:CablingSw:transport managed object property

cfprFabricCablingSwType

1.3.6.1.4.1.9.9.826.1.26.4.1.8

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:CablingSw:type managed object property

cfprFabricCdpLinkPolicyTable

1.3.6.1.4.1.9.9.826.1.26.5

Index: cfprFabricCdpLinkPolicyInstanceId

Cisco Firepower fabric:CdpLinkPolicy managed object table

cfprFabricCdpLinkPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.26.5.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricCdpLinkPolicyDn

1.3.6.1.4.1.9.9.826.1.26.5.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:CdpLinkPolicy:dn managed object property

cfprFabricCdpLinkPolicyRn

1.3.6.1.4.1.9.9.826.1.26.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:CdpLinkPolicy:rn managed object property

cfprFabricCdpLinkPolicyAdminState

1.3.6.1.4.1.9.9.826.1.26.5.1.4

CfprFabricCdpLinkPolicyAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:CdpLinkPolicy:adminState managed object property

cfprFabricCdpLinkPolicyDescr

1.3.6.1.4.1.9.9.826.1.26.5.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:CdpLinkPolicy:descr managed object property

cfprFabricCdpLinkPolicyIntId

1.3.6.1.4.1.9.9.826.1.26.5.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:CdpLinkPolicy:intId managed object property

cfprFabricCdpLinkPolicyName

1.3.6.1.4.1.9.9.826.1.26.5.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:CdpLinkPolicy:name managed object property

cfprFabricCdpLinkPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.5.1.8

Gauge32

Cisco Firepower fabric:CdpLinkPolicy:policyLevel managed object property

cfprFabricCdpLinkPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.5.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:CdpLinkPolicy:policyOwner managed object property

cfprFabricCdpLinkPolicyProtocol

1.3.6.1.4.1.9.9.826.1.26.5.1.10

CfprFabricEthCdpPolicyProtocol0 = unknown1 = udld2 = cdp · Integer32

Cisco Firepower fabric:CdpLinkPolicy:protocol managed object property

cfprFabricCdpLinkPolicyType

1.3.6.1.4.1.9.9.826.1.26.5.1.11

CfprFabricEthLinkPolicyType · BITS

Cisco Firepower fabric:CdpLinkPolicy:type managed object property

cfprFabricChangedObjectRefTable

1.3.6.1.4.1.9.9.826.1.26.6

Index: cfprFabricChangedObjectRefInstanceId

Cisco Firepower fabric:ChangedObjectRef managed object table

cfprFabricChangedObjectRefInstanceId

1.3.6.1.4.1.9.9.826.1.26.6.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricChangedObjectRefDn

1.3.6.1.4.1.9.9.826.1.26.6.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ChangedObjectRef:dn managed object property

cfprFabricChangedObjectRefRn

1.3.6.1.4.1.9.9.826.1.26.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChangedObjectRef:rn managed object property

cfprFabricChangedObjectRefCentraleVnetEpDn

1.3.6.1.4.1.9.9.826.1.26.6.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChangedObjectRef:centraleVnetEpDn managed object property

cfprFabricChangedObjectRefId

1.3.6.1.4.1.9.9.826.1.26.6.1.5

Gauge32

Cisco Firepower fabric:ChangedObjectRef:id managed object property

cfprFabricChangedObjectRefOldCentraleVnetEpDn

1.3.6.1.4.1.9.9.826.1.26.6.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChangedObjectRef:oldCentraleVnetEpDn managed object property

cfprFabricChangedObjectRefRefObjStatus

1.3.6.1.4.1.9.9.826.1.26.6.1.7

CfprFabricStatus0 = modified1 = created2 = deleted3 = intentDeletion · Integer32

Cisco Firepower fabric:ChangedObjectRef:refObjStatus managed object property

cfprFabricChangedObjectRefFprmVnetEpDn

1.3.6.1.4.1.9.9.826.1.26.6.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChangedObjectRef:fprmVnetEpDn managed object property

cfprFabricChassisEpTable

1.3.6.1.4.1.9.9.826.1.26.7

Index: cfprFabricChassisEpInstanceId

Cisco Firepower fabric:ChassisEp managed object table

cfprFabricChassisEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.7.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricChassisEpDn

1.3.6.1.4.1.9.9.826.1.26.7.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ChassisEp:dn managed object property

cfprFabricChassisEpRn

1.3.6.1.4.1.9.9.826.1.26.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:rn managed object property

cfprFabricChassisEpAdminState

1.3.6.1.4.1.9.9.826.1.26.7.1.4

CfprFabricInternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:ChassisEp:adminState managed object property

cfprFabricChassisEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.7.1.5

Gauge32

Cisco Firepower fabric:ChassisEp:aggrPortId managed object property

cfprFabricChassisEpChassisDn

1.3.6.1.4.1.9.9.826.1.26.7.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:chassisDn managed object property

cfprFabricChassisEpChassisId

1.3.6.1.4.1.9.9.826.1.26.7.1.7

Gauge32

Cisco Firepower fabric:ChassisEp:chassisId managed object property

cfprFabricChassisEpEpDn

1.3.6.1.4.1.9.9.826.1.26.7.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:epDn managed object property

cfprFabricChassisEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.7.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ChassisEp:fltAggr managed object property

cfprFabricChassisEpIfRole

1.3.6.1.4.1.9.9.826.1.26.7.1.10

CfprFabricComputeEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:ChassisEp:ifRole managed object property

cfprFabricChassisEpIfType

1.3.6.1.4.1.9.9.826.1.26.7.1.11

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:ChassisEp:ifType managed object property

cfprFabricChassisEpLicGP

1.3.6.1.4.1.9.9.826.1.26.7.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ChassisEp:licGP managed object property

cfprFabricChassisEpLicState

1.3.6.1.4.1.9.9.826.1.26.7.1.13

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:ChassisEp:licState managed object property

cfprFabricChassisEpLocale

1.3.6.1.4.1.9.9.826.1.26.7.1.14

CfprFabricInternalEpLocale · BITS

Cisco Firepower fabric:ChassisEp:locale managed object property

cfprFabricChassisEpModel

1.3.6.1.4.1.9.9.826.1.26.7.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:model managed object property

cfprFabricChassisEpName

1.3.6.1.4.1.9.9.826.1.26.7.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:name managed object property

cfprFabricChassisEpOperState

1.3.6.1.4.1.9.9.826.1.26.7.1.17

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:ChassisEp:operState managed object property

cfprFabricChassisEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.7.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:operStateReason managed object property

cfprFabricChassisEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.7.1.19

Gauge32

Cisco Firepower fabric:ChassisEp:peerAggrPortId managed object property

cfprFabricChassisEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.7.1.20

Gauge32

Cisco Firepower fabric:ChassisEp:peerChassisId managed object property

cfprFabricChassisEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.7.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:peerDn managed object property

cfprFabricChassisEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.7.1.22

Gauge32

Cisco Firepower fabric:ChassisEp:peerPortId managed object property

cfprFabricChassisEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.7.1.23

Gauge32

Cisco Firepower fabric:ChassisEp:peerSlotId managed object property

cfprFabricChassisEpPortId

1.3.6.1.4.1.9.9.826.1.26.7.1.24

CfprFabricPIoEpPortId (1..48) · Gauge32

Cisco Firepower fabric:ChassisEp:portId managed object property

cfprFabricChassisEpRevision

1.3.6.1.4.1.9.9.826.1.26.7.1.25

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:revision managed object property

cfprFabricChassisEpSerial

1.3.6.1.4.1.9.9.826.1.26.7.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:serial managed object property

cfprFabricChassisEpSlotId

1.3.6.1.4.1.9.9.826.1.26.7.1.27

CfprFabricPIoEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:ChassisEp:slotId managed object property

cfprFabricChassisEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.7.1.28

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:ChassisEp:switchId managed object property

cfprFabricChassisEpTransport

1.3.6.1.4.1.9.9.826.1.26.7.1.29

CfprNetworkTransport · BITS

Cisco Firepower fabric:ChassisEp:transport managed object property

cfprFabricChassisEpType

1.3.6.1.4.1.9.9.826.1.26.7.1.30

CfprFabricComputeEpType · BITS

Cisco Firepower fabric:ChassisEp:type managed object property

cfprFabricChassisEpVendor

1.3.6.1.4.1.9.9.826.1.26.7.1.31

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ChassisEp:vendor managed object property

cfprFabricComputePhEpTable

1.3.6.1.4.1.9.9.826.1.26.8

Index: cfprFabricComputePhEpInstanceId

Cisco Firepower fabric:ComputePhEp managed object table

cfprFabricComputePhEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.8.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricComputePhEpDn

1.3.6.1.4.1.9.9.826.1.26.8.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ComputePhEp:dn managed object property

cfprFabricComputePhEpRn

1.3.6.1.4.1.9.9.826.1.26.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:rn managed object property

cfprFabricComputePhEpAdminState

1.3.6.1.4.1.9.9.826.1.26.8.1.4

CfprFabricComputePhEpAdminState1 = enabled2 = disabled3 = remove · Integer32

Cisco Firepower fabric:ComputePhEp:adminState managed object property

cfprFabricComputePhEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.8.1.5

Gauge32

Cisco Firepower fabric:ComputePhEp:aggrPortId managed object property

cfprFabricComputePhEpBoardAggregationRole

1.3.6.1.4.1.9.9.826.1.26.8.1.6

CfprEquipmentBoardAggregationRole0 = none1 = single2 = multiMaster3 = multiSlave · Integer32

Cisco Firepower fabric:ComputePhEp:boardAggregationRole managed object property

cfprFabricComputePhEpChassisId

1.3.6.1.4.1.9.9.826.1.26.8.1.7

Gauge32

Cisco Firepower fabric:ComputePhEp:chassisId managed object property

cfprFabricComputePhEpCheckpointTrigTs

1.3.6.1.4.1.9.9.826.1.26.8.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputePhEp:checkpointTrigTs managed object property

cfprFabricComputePhEpDeepCheckpointTrigTs

1.3.6.1.4.1.9.9.826.1.26.8.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputePhEp:deepCheckpointTrigTs managed object property

cfprFabricComputePhEpDiscTrigTs

1.3.6.1.4.1.9.9.826.1.26.8.1.10

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputePhEp:discTrigTs managed object property

cfprFabricComputePhEpEpDn

1.3.6.1.4.1.9.9.826.1.26.8.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:epDn managed object property

cfprFabricComputePhEpEqType

1.3.6.1.4.1.9.9.826.1.26.8.1.12

CfprEquipmentFabricEpType0 = unknown1 = chassis2 = fex3 = blade4 = rackUnit · Integer32

Cisco Firepower fabric:ComputePhEp:eqType managed object property

cfprFabricComputePhEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.8.1.13

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputePhEp:fltAggr managed object property

cfprFabricComputePhEpIfRole

1.3.6.1.4.1.9.9.826.1.26.8.1.14

CfprFabricComputeEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:ComputePhEp:ifRole managed object property

cfprFabricComputePhEpIfType

1.3.6.1.4.1.9.9.826.1.26.8.1.15

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:ComputePhEp:ifType managed object property

cfprFabricComputePhEpLc

1.3.6.1.4.1.9.9.826.1.26.8.1.16

CfprFabricBladeLifeCycle1 = inService2 = outOfService3 = outOfServiceSlave · Integer32

Cisco Firepower fabric:ComputePhEp:lc managed object property

cfprFabricComputePhEpLicGP

1.3.6.1.4.1.9.9.826.1.26.8.1.17

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputePhEp:licGP managed object property

cfprFabricComputePhEpLicState

1.3.6.1.4.1.9.9.826.1.26.8.1.18

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:ComputePhEp:licState managed object property

cfprFabricComputePhEpLocale

1.3.6.1.4.1.9.9.826.1.26.8.1.19

CfprFabricInternalEpLocale · BITS

Cisco Firepower fabric:ComputePhEp:locale managed object property

cfprFabricComputePhEpModel

1.3.6.1.4.1.9.9.826.1.26.8.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:model managed object property

cfprFabricComputePhEpName

1.3.6.1.4.1.9.9.826.1.26.8.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:name managed object property

cfprFabricComputePhEpOperState

1.3.6.1.4.1.9.9.826.1.26.8.1.22

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:ComputePhEp:operState managed object property

cfprFabricComputePhEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.8.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:operStateReason managed object property

cfprFabricComputePhEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.8.1.24

Gauge32

Cisco Firepower fabric:ComputePhEp:peerAggrPortId managed object property

cfprFabricComputePhEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.8.1.25

Gauge32

Cisco Firepower fabric:ComputePhEp:peerChassisId managed object property

cfprFabricComputePhEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.8.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:peerDn managed object property

cfprFabricComputePhEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.8.1.27

Gauge32

Cisco Firepower fabric:ComputePhEp:peerPortId managed object property

cfprFabricComputePhEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.8.1.28

Gauge32

Cisco Firepower fabric:ComputePhEp:peerSlotId managed object property

cfprFabricComputePhEpPortId

1.3.6.1.4.1.9.9.826.1.26.8.1.29

CfprFabricPIoEpPortId (1..48) · Gauge32

Cisco Firepower fabric:ComputePhEp:portId managed object property

cfprFabricComputePhEpProfileDn

1.3.6.1.4.1.9.9.826.1.26.8.1.30

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:profileDn managed object property

cfprFabricComputePhEpRevision

1.3.6.1.4.1.9.9.826.1.26.8.1.31

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:revision managed object property

cfprFabricComputePhEpSerial

1.3.6.1.4.1.9.9.826.1.26.8.1.32

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:serial managed object property

cfprFabricComputePhEpSlotId

1.3.6.1.4.1.9.9.826.1.26.8.1.33

CfprFabricPIoEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:ComputePhEp:slotId managed object property

cfprFabricComputePhEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.8.1.34

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:ComputePhEp:switchId managed object property

cfprFabricComputePhEpTransport

1.3.6.1.4.1.9.9.826.1.26.8.1.35

CfprNetworkTransport · BITS

Cisco Firepower fabric:ComputePhEp:transport managed object property

cfprFabricComputePhEpType

1.3.6.1.4.1.9.9.826.1.26.8.1.36

CfprFabricComputeEpType · BITS

Cisco Firepower fabric:ComputePhEp:type managed object property

cfprFabricComputePhEpVendor

1.3.6.1.4.1.9.9.826.1.26.8.1.37

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputePhEp:vendor managed object property

cfprFabricComputeSlotEpTable

1.3.6.1.4.1.9.9.826.1.26.9

Index: cfprFabricComputeSlotEpInstanceId

Cisco Firepower fabric:ComputeSlotEp managed object table

cfprFabricComputeSlotEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.9.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricComputeSlotEpDn

1.3.6.1.4.1.9.9.826.1.26.9.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ComputeSlotEp:dn managed object property

cfprFabricComputeSlotEpRn

1.3.6.1.4.1.9.9.826.1.26.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:rn managed object property

cfprFabricComputeSlotEpAdminState

1.3.6.1.4.1.9.9.826.1.26.9.1.4

CfprFabricSlotAdminState1 = acknowledged3 = reacknowledge · Integer32

Cisco Firepower fabric:ComputeSlotEp:adminState managed object property

cfprFabricComputeSlotEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.9.1.5

Gauge32

Cisco Firepower fabric:ComputeSlotEp:aggrPortId managed object property

cfprFabricComputeSlotEpBoardAggregationRole

1.3.6.1.4.1.9.9.826.1.26.9.1.6

CfprEquipmentBoardAggregationRole0 = none1 = single2 = multiMaster3 = multiSlave · Integer32

Cisco Firepower fabric:ComputeSlotEp:boardAggregationRole managed object property

cfprFabricComputeSlotEpChassisId

1.3.6.1.4.1.9.9.826.1.26.9.1.7

Gauge32

Cisco Firepower fabric:ComputeSlotEp:chassisId managed object property

cfprFabricComputeSlotEpConnPath

1.3.6.1.4.1.9.9.826.1.26.9.1.8

CfprEquipmentConnectionStatus · BITS

Cisco Firepower fabric:ComputeSlotEp:connPath managed object property

cfprFabricComputeSlotEpConnStatus

1.3.6.1.4.1.9.9.826.1.26.9.1.9

CfprEquipmentConnectionStatus · BITS

Cisco Firepower fabric:ComputeSlotEp:connStatus managed object property

cfprFabricComputeSlotEpDiscovery

1.3.6.1.4.1.9.9.826.1.26.9.1.10

CfprComputeDiscovery0 = undiscovered1 = inProgress2 = malformedFruInfo3 = fruNotReady4 = insufficientlyEquipped5 = invalidAdaptorIocard8 = failed16 = complete32 = retry64 = throttled128 = illegalFru129 = fruIdentityIndeterminate130 = fruStateIndeterminate131 = diagnosticsInProgress132 = efidiagnosticsInProgress133 = diagnosticsFailed134 = diagnosticsComplete135 = waitingForUserAck136 = userAcknowledged137 = waitingForMgmtAck138 = illegalPartNumber · Integer32

Cisco Firepower fabric:ComputeSlotEp:discovery managed object property

cfprFabricComputeSlotEpEpDn

1.3.6.1.4.1.9.9.826.1.26.9.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:epDn managed object property

cfprFabricComputeSlotEpFactoryResetFlag

1.3.6.1.4.1.9.9.826.1.26.9.1.12

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:ComputeSlotEp:factoryResetFlag managed object property

cfprFabricComputeSlotEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.9.1.13

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputeSlotEp:fltAggr managed object property

cfprFabricComputeSlotEpFruIdentTrigTs

1.3.6.1.4.1.9.9.826.1.26.9.1.14

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputeSlotEp:fruIdentTrigTs managed object property

cfprFabricComputeSlotEpFsmDescr

1.3.6.1.4.1.9.9.826.1.26.9.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:fsmDescr managed object property

cfprFabricComputeSlotEpFsmPrev

1.3.6.1.4.1.9.9.826.1.26.9.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:fsmPrev managed object property

cfprFabricComputeSlotEpFsmProgr

1.3.6.1.4.1.9.9.826.1.26.9.1.17

Gauge32

Cisco Firepower fabric:ComputeSlotEp:fsmProgr managed object property

cfprFabricComputeSlotEpFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.26.9.1.18

Gauge32

Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvErrCode managed object property

cfprFabricComputeSlotEpFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.26.9.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvErrDescr managed object property

cfprFabricComputeSlotEpFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.26.9.1.20

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:ComputeSlotEp:fsmRmtInvRslt managed object property

cfprFabricComputeSlotEpFsmStageDescr

1.3.6.1.4.1.9.9.826.1.26.9.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:fsmStageDescr managed object property

cfprFabricComputeSlotEpFsmStamp

1.3.6.1.4.1.9.9.826.1.26.9.1.22

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:ComputeSlotEp:fsmStamp managed object property

cfprFabricComputeSlotEpFsmStatus

1.3.6.1.4.1.9.9.826.1.26.9.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:fsmStatus managed object property

cfprFabricComputeSlotEpFsmTry

1.3.6.1.4.1.9.9.826.1.26.9.1.24

Gauge32

Cisco Firepower fabric:ComputeSlotEp:fsmTry managed object property

cfprFabricComputeSlotEpIfRole

1.3.6.1.4.1.9.9.826.1.26.9.1.25

CfprFabricComputeEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:ComputeSlotEp:ifRole managed object property

cfprFabricComputeSlotEpIfType

1.3.6.1.4.1.9.9.826.1.26.9.1.26

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:ComputeSlotEp:ifType managed object property

cfprFabricComputeSlotEpLcTs

1.3.6.1.4.1.9.9.826.1.26.9.1.27

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:ComputeSlotEp:lcTs managed object property

cfprFabricComputeSlotEpLicGP

1.3.6.1.4.1.9.9.826.1.26.9.1.28

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:ComputeSlotEp:licGP managed object property

cfprFabricComputeSlotEpLicState

1.3.6.1.4.1.9.9.826.1.26.9.1.29

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:ComputeSlotEp:licState managed object property

cfprFabricComputeSlotEpLocale

1.3.6.1.4.1.9.9.826.1.26.9.1.30

CfprFabricInternalEpLocale · BITS

Cisco Firepower fabric:ComputeSlotEp:locale managed object property

cfprFabricComputeSlotEpManagingInst

1.3.6.1.4.1.9.9.826.1.26.9.1.31

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:ComputeSlotEp:managingInst managed object property

cfprFabricComputeSlotEpModel

1.3.6.1.4.1.9.9.826.1.26.9.1.32

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:model managed object property

cfprFabricComputeSlotEpName

1.3.6.1.4.1.9.9.826.1.26.9.1.33

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:name managed object property

cfprFabricComputeSlotEpOperState

1.3.6.1.4.1.9.9.826.1.26.9.1.34

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:ComputeSlotEp:operState managed object property

cfprFabricComputeSlotEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.9.1.35

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:operStateReason managed object property

cfprFabricComputeSlotEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.9.1.36

Gauge32

Cisco Firepower fabric:ComputeSlotEp:peerAggrPortId managed object property

cfprFabricComputeSlotEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.9.1.37

Gauge32

Cisco Firepower fabric:ComputeSlotEp:peerChassisId managed object property

cfprFabricComputeSlotEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.9.1.38

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:peerDn managed object property

cfprFabricComputeSlotEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.9.1.39

Gauge32

Cisco Firepower fabric:ComputeSlotEp:peerPortId managed object property

cfprFabricComputeSlotEpPeerSlotEpDn

1.3.6.1.4.1.9.9.826.1.26.9.1.40

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:peerSlotEpDn managed object property

cfprFabricComputeSlotEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.9.1.41

Gauge32

Cisco Firepower fabric:ComputeSlotEp:peerSlotId managed object property

cfprFabricComputeSlotEpPortId

1.3.6.1.4.1.9.9.826.1.26.9.1.42

CfprFabricPIoEpPortId (1..48) · Gauge32

Cisco Firepower fabric:ComputeSlotEp:portId managed object property

cfprFabricComputeSlotEpPresence

1.3.6.1.4.1.9.9.826.1.26.9.1.43

CfprEquipmentSlotStatus0 = unknown1 = empty10 = equipped11 = missing12 = mismatch13 = equippedNotPrimary14 = equippedSlave15 = mismatchSlave16 = missingSlave20 = equippedIdentityUnestablishable21 = mismatchIdentityUnestablishable22 = equippedWithMalformedFru30 = inaccessible40 = unauthorized · Integer32

Cisco Firepower fabric:ComputeSlotEp:presence managed object property

cfprFabricComputeSlotEpPresencePath

1.3.6.1.4.1.9.9.826.1.26.9.1.44

CfprEquipmentConnectionStatus · BITS

Cisco Firepower fabric:ComputeSlotEp:presencePath managed object property

cfprFabricComputeSlotEpRevision

1.3.6.1.4.1.9.9.826.1.26.9.1.45

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:revision managed object property

cfprFabricComputeSlotEpSerial

1.3.6.1.4.1.9.9.826.1.26.9.1.46

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:serial managed object property

cfprFabricComputeSlotEpSlotId

1.3.6.1.4.1.9.9.826.1.26.9.1.47

CfprFabricComputeSlotEpSlotId (1..8) · Gauge32

Cisco Firepower fabric:ComputeSlotEp:slotId managed object property

cfprFabricComputeSlotEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.9.1.48

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:ComputeSlotEp:switchId managed object property

cfprFabricComputeSlotEpTransport

1.3.6.1.4.1.9.9.826.1.26.9.1.49

CfprNetworkTransport · BITS

Cisco Firepower fabric:ComputeSlotEp:transport managed object property

cfprFabricComputeSlotEpType

1.3.6.1.4.1.9.9.826.1.26.9.1.50

CfprFabricComputeEpType · BITS

Cisco Firepower fabric:ComputeSlotEp:type managed object property

cfprFabricComputeSlotEpVendor

1.3.6.1.4.1.9.9.826.1.26.9.1.51

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:vendor managed object property

cfprFabricComputeSlotEpBladeState

1.3.6.1.4.1.9.9.826.1.26.9.1.52

CfprLsOperState0 = indeterminate1 = unassociated10 = ok11 = discovery12 = config13 = unconfig14 = powerOff15 = restart20 = maintenance21 = test29 = computeMismatch30 = computeFailed31 = degraded32 = discoveryFailed33 = configFailure34 = unconfigFailed35 = testFailed36 = maintenanceFailed40 = removed41 = disabled50 = inaccessible60 = thermalProblem61 = powerProblem62 = voltageProblem63 = inoperable101 = decomissioning102 = decomissioned201 = biosRestore202 = cmosReset203 = diagnostics204 = diagnosticsFailed210 = pendingReboot211 = pendingReassociation212 = svnicNotPresent · Integer32

Cisco Firepower fabric:ComputeSlotEp:bladeState managed object property

cfprFabricComputeSlotEpDecommissionSecure

1.3.6.1.4.1.9.9.826.1.26.9.1.53

CfprComputeDecommissionState0 = none1 = succeeded2 = failed3 = inProgress · Integer32

Cisco Firepower fabric:ComputeSlotEp:decommissionSecure managed object property

cfprFabricComputeSlotEpFailReason

1.3.6.1.4.1.9.9.826.1.26.9.1.54

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEp:failReason managed object property

cfprFabricComputeSlotEpFsmTable

1.3.6.1.4.1.9.9.826.1.26.10

Index: cfprFabricComputeSlotEpFsmInstanceId

Cisco Firepower fabric:ComputeSlotEpFsm managed object table

cfprFabricComputeSlotEpFsmInstanceId

1.3.6.1.4.1.9.9.826.1.26.10.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricComputeSlotEpFsmDn

1.3.6.1.4.1.9.9.826.1.26.10.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ComputeSlotEpFsm:dn managed object property

cfprFabricComputeSlotEpFsmRn

1.3.6.1.4.1.9.9.826.1.26.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEpFsm:rn managed object property

cfprFabricComputeSlotEpFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.26.10.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:ComputeSlotEpFsm:completionTime managed object property

cfprFabricComputeSlotEpFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.26.10.1.5

CfprFabricComputeSlotEpFsmCurrentFsm0 = nop20 = identify · Integer32

Cisco Firepower fabric:ComputeSlotEpFsm:currentFsm managed object property

cfprFabricComputeSlotEpFsmDescrData

1.3.6.1.4.1.9.9.826.1.26.10.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEpFsm:descr managed object property

cfprFabricComputeSlotEpFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.26.10.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:ComputeSlotEpFsm:fsmStatus managed object property

cfprFabricComputeSlotEpFsmProgress

1.3.6.1.4.1.9.9.826.1.26.10.1.8

Gauge32

Cisco Firepower fabric:ComputeSlotEpFsm:progress managed object property

cfprFabricComputeSlotEpFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.26.10.1.9

Gauge32

Cisco Firepower fabric:ComputeSlotEpFsm:rmtErrCode managed object property

cfprFabricComputeSlotEpFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.26.10.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEpFsm:rmtErrDescr managed object property

cfprFabricComputeSlotEpFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.26.10.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:ComputeSlotEpFsm:rmtRslt managed object property

cfprFabricComputeSlotEpFsmStageTable

1.3.6.1.4.1.9.9.826.1.26.11

Index: cfprFabricComputeSlotEpFsmStageInstanceId

Cisco Firepower fabric:ComputeSlotEpFsmStage managed object table

cfprFabricComputeSlotEpFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.26.11.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricComputeSlotEpFsmStageDn

1.3.6.1.4.1.9.9.826.1.26.11.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ComputeSlotEpFsmStage:dn managed object property

cfprFabricComputeSlotEpFsmStageRn

1.3.6.1.4.1.9.9.826.1.26.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEpFsmStage:rn managed object property

cfprFabricComputeSlotEpFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.26.11.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEpFsmStage:descr managed object property

cfprFabricComputeSlotEpFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.26.11.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:ComputeSlotEpFsmStage:lastUpdateTime managed object property

cfprFabricComputeSlotEpFsmStageName

1.3.6.1.4.1.9.9.826.1.26.11.1.6

CfprFabricComputeSlotEpFsmStageName0 = nop20 = identifyBegin21 = identifyExecuteLocal22 = identifyExecutePeer390 = identifyFail391 = identifySuccess · Integer32

Cisco Firepower fabric:ComputeSlotEpFsmStage:name managed object property

cfprFabricComputeSlotEpFsmStageOrder

1.3.6.1.4.1.9.9.826.1.26.11.1.7

Gauge32

Cisco Firepower fabric:ComputeSlotEpFsmStage:order managed object property

cfprFabricComputeSlotEpFsmStageRetry

1.3.6.1.4.1.9.9.826.1.26.11.1.8

Gauge32

Cisco Firepower fabric:ComputeSlotEpFsmStage:retry managed object property

cfprFabricComputeSlotEpFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.26.11.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:ComputeSlotEpFsmStage:stageStatus managed object property

cfprFabricComputeSlotEpFsmTaskTable

1.3.6.1.4.1.9.9.826.1.26.12

Index: cfprFabricComputeSlotEpFsmTaskInstanceId

Cisco Firepower fabric:ComputeSlotEpFsmTask managed object table

cfprFabricComputeSlotEpFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.26.12.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricComputeSlotEpFsmTaskDn

1.3.6.1.4.1.9.9.826.1.26.12.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ComputeSlotEpFsmTask:dn managed object property

cfprFabricComputeSlotEpFsmTaskRn

1.3.6.1.4.1.9.9.826.1.26.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ComputeSlotEpFsmTask:rn managed object property

cfprFabricComputeSlotEpFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.26.12.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower fabric:ComputeSlotEpFsmTask:completion managed object property

cfprFabricComputeSlotEpFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.26.12.1.5

CfprFsmFlags · BITS

Cisco Firepower fabric:ComputeSlotEpFsmTask:flags managed object property

cfprFabricComputeSlotEpFsmTaskItem

1.3.6.1.4.1.9.9.826.1.26.12.1.6

CfprFabricComputeSlotEpFsmTaskItem0 = nop20 = identify · Integer32

Cisco Firepower fabric:ComputeSlotEpFsmTask:item managed object property

cfprFabricComputeSlotEpFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.26.12.1.7

Gauge32

Cisco Firepower fabric:ComputeSlotEpFsmTask:seqId managed object property

cfprFabricDceSrvTable

1.3.6.1.4.1.9.9.826.1.26.13

Index: cfprFabricDceSrvInstanceId

Cisco Firepower fabric:DceSrv managed object table

cfprFabricDceSrvInstanceId

1.3.6.1.4.1.9.9.826.1.26.13.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricDceSrvDn

1.3.6.1.4.1.9.9.826.1.26.13.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:DceSrv:dn managed object property

cfprFabricDceSrvRn

1.3.6.1.4.1.9.9.826.1.26.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSrv:rn managed object property

cfprFabricDceSrvId

1.3.6.1.4.1.9.9.826.1.26.13.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:DceSrv:id managed object property

cfprFabricDceSrvLocale

1.3.6.1.4.1.9.9.826.1.26.13.1.5

CfprFabricInternalLocale · BITS

Cisco Firepower fabric:DceSrv:locale managed object property

cfprFabricDceSrvName

1.3.6.1.4.1.9.9.826.1.26.13.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSrv:name managed object property

cfprFabricDceSrvTransport

1.3.6.1.4.1.9.9.826.1.26.13.1.7

CfprFabricInternalDceSrvTransport · BITS

Cisco Firepower fabric:DceSrv:transport managed object property

cfprFabricDceSrvType

1.3.6.1.4.1.9.9.826.1.26.13.1.8

CfprFabricInternalDceSrvType · BITS

Cisco Firepower fabric:DceSrv:type managed object property

cfprFabricDceSwSrvTable

1.3.6.1.4.1.9.9.826.1.26.14

Index: cfprFabricDceSwSrvInstanceId

Cisco Firepower fabric:DceSwSrv managed object table

cfprFabricDceSwSrvInstanceId

1.3.6.1.4.1.9.9.826.1.26.14.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricDceSwSrvDn

1.3.6.1.4.1.9.9.826.1.26.14.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:DceSwSrv:dn managed object property

cfprFabricDceSwSrvRn

1.3.6.1.4.1.9.9.826.1.26.14.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrv:rn managed object property

cfprFabricDceSwSrvId

1.3.6.1.4.1.9.9.826.1.26.14.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:DceSwSrv:id managed object property

cfprFabricDceSwSrvLocale

1.3.6.1.4.1.9.9.826.1.26.14.1.5

CfprFabricInternalLocale · BITS

Cisco Firepower fabric:DceSwSrv:locale managed object property

cfprFabricDceSwSrvName

1.3.6.1.4.1.9.9.826.1.26.14.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrv:name managed object property

cfprFabricDceSwSrvTransport

1.3.6.1.4.1.9.9.826.1.26.14.1.7

CfprFabricInternalDceSrvTransport · BITS

Cisco Firepower fabric:DceSwSrv:transport managed object property

cfprFabricDceSwSrvType

1.3.6.1.4.1.9.9.826.1.26.14.1.8

CfprFabricInternalDceSrvType · BITS

Cisco Firepower fabric:DceSwSrv:type managed object property

cfprFabricDceSwSrvEpTable

1.3.6.1.4.1.9.9.826.1.26.15

Index: cfprFabricDceSwSrvEpInstanceId

Cisco Firepower fabric:DceSwSrvEp managed object table

cfprFabricDceSwSrvEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.15.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricDceSwSrvEpDn

1.3.6.1.4.1.9.9.826.1.26.15.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:DceSwSrvEp:dn managed object property

cfprFabricDceSwSrvEpRn

1.3.6.1.4.1.9.9.826.1.26.15.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvEp:rn managed object property

cfprFabricDceSwSrvEpAdminState

1.3.6.1.4.1.9.9.826.1.26.15.1.4

CfprFabricInternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:DceSwSrvEp:adminState managed object property

cfprFabricDceSwSrvEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.15.1.5

Gauge32

Cisco Firepower fabric:DceSwSrvEp:aggrPortId managed object property

cfprFabricDceSwSrvEpChassisId

1.3.6.1.4.1.9.9.826.1.26.15.1.6

Gauge32

Cisco Firepower fabric:DceSwSrvEp:chassisId managed object property

cfprFabricDceSwSrvEpEpDn

1.3.6.1.4.1.9.9.826.1.26.15.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvEp:epDn managed object property

cfprFabricDceSwSrvEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.15.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:DceSwSrvEp:fltAggr managed object property

cfprFabricDceSwSrvEpIfRole

1.3.6.1.4.1.9.9.826.1.26.15.1.9

CfprFabricSwSrvEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:DceSwSrvEp:ifRole managed object property

cfprFabricDceSwSrvEpIfType

1.3.6.1.4.1.9.9.826.1.26.15.1.10

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:DceSwSrvEp:ifType managed object property

cfprFabricDceSwSrvEpLicGP

1.3.6.1.4.1.9.9.826.1.26.15.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:DceSwSrvEp:licGP managed object property

cfprFabricDceSwSrvEpLicState

1.3.6.1.4.1.9.9.826.1.26.15.1.12

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:DceSwSrvEp:licState managed object property

cfprFabricDceSwSrvEpLocale

1.3.6.1.4.1.9.9.826.1.26.15.1.13

CfprFabricInternalEpLocale · BITS

Cisco Firepower fabric:DceSwSrvEp:locale managed object property

cfprFabricDceSwSrvEpName

1.3.6.1.4.1.9.9.826.1.26.15.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvEp:name managed object property

cfprFabricDceSwSrvEpOperState

1.3.6.1.4.1.9.9.826.1.26.15.1.15

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:DceSwSrvEp:operState managed object property

cfprFabricDceSwSrvEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.15.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvEp:operStateReason managed object property

cfprFabricDceSwSrvEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.15.1.17

Gauge32

Cisco Firepower fabric:DceSwSrvEp:peerAggrPortId managed object property

cfprFabricDceSwSrvEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.15.1.18

Gauge32

Cisco Firepower fabric:DceSwSrvEp:peerChassisId managed object property

cfprFabricDceSwSrvEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.15.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvEp:peerDn managed object property

cfprFabricDceSwSrvEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.15.1.20

Gauge32

Cisco Firepower fabric:DceSwSrvEp:peerPortId managed object property

cfprFabricDceSwSrvEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.15.1.21

Gauge32

Cisco Firepower fabric:DceSwSrvEp:peerSlotId managed object property

cfprFabricDceSwSrvEpPortId

1.3.6.1.4.1.9.9.826.1.26.15.1.22

CfprFabricDceSwSrvEpPortId (1..48) · Gauge32

Cisco Firepower fabric:DceSwSrvEp:portId managed object property

cfprFabricDceSwSrvEpSlotId

1.3.6.1.4.1.9.9.826.1.26.15.1.23

CfprFabricDceSwSrvEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:DceSwSrvEp:slotId managed object property

cfprFabricDceSwSrvEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.15.1.24

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:DceSwSrvEp:switchId managed object property

cfprFabricDceSwSrvEpTransport

1.3.6.1.4.1.9.9.826.1.26.15.1.25

CfprFabricADceSwSrvEpTransport · BITS

Cisco Firepower fabric:DceSwSrvEp:transport managed object property

cfprFabricDceSwSrvEpType

1.3.6.1.4.1.9.9.826.1.26.15.1.26

CfprFabricSwSrvEpType · BITS

Cisco Firepower fabric:DceSwSrvEp:type managed object property

cfprFabricDceSwSrvEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.15.1.27

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvEp:usrLbl managed object property

cfprFabricDceSwSrvPcTable

1.3.6.1.4.1.9.9.826.1.26.16

Index: cfprFabricDceSwSrvPcInstanceId

Cisco Firepower fabric:DceSwSrvPc managed object table

cfprFabricDceSwSrvPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.16.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricDceSwSrvPcDn

1.3.6.1.4.1.9.9.826.1.26.16.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:DceSwSrvPc:dn managed object property

cfprFabricDceSwSrvPcRn

1.3.6.1.4.1.9.9.826.1.26.16.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPc:rn managed object property

cfprFabricDceSwSrvPcAdminState

1.3.6.1.4.1.9.9.826.1.26.16.1.4

CfprFabricDceSwSrvPcAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:DceSwSrvPc:adminState managed object property

cfprFabricDceSwSrvPcChassisId

1.3.6.1.4.1.9.9.826.1.26.16.1.5

Gauge32

Cisco Firepower fabric:DceSwSrvPc:chassisId managed object property

cfprFabricDceSwSrvPcDescr

1.3.6.1.4.1.9.9.826.1.26.16.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPc:descr managed object property

cfprFabricDceSwSrvPcEpDn

1.3.6.1.4.1.9.9.826.1.26.16.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPc:epDn managed object property

cfprFabricDceSwSrvPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.16.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:DceSwSrvPc:fltAggr managed object property

cfprFabricDceSwSrvPcIfRole

1.3.6.1.4.1.9.9.826.1.26.16.1.9

CfprFabricSwSrvPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:DceSwSrvPc:ifRole managed object property

cfprFabricDceSwSrvPcIfType

1.3.6.1.4.1.9.9.826.1.26.16.1.10

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:DceSwSrvPc:ifType managed object property

cfprFabricDceSwSrvPcLocale

1.3.6.1.4.1.9.9.826.1.26.16.1.11

CfprFabricInternalPcLocale · BITS

Cisco Firepower fabric:DceSwSrvPc:locale managed object property

cfprFabricDceSwSrvPcName

1.3.6.1.4.1.9.9.826.1.26.16.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPc:name managed object property

cfprFabricDceSwSrvPcOperSpeed

1.3.6.1.4.1.9.9.826.1.26.16.1.13

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:DceSwSrvPc:operSpeed managed object property

cfprFabricDceSwSrvPcOperState

1.3.6.1.4.1.9.9.826.1.26.16.1.14

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:DceSwSrvPc:operState managed object property

cfprFabricDceSwSrvPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.16.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPc:peerDn managed object property

cfprFabricDceSwSrvPcPortId

1.3.6.1.4.1.9.9.826.1.26.16.1.16

CfprFabricDceSwSrvPcPortId (1024..4096) · Gauge32

Cisco Firepower fabric:DceSwSrvPc:portId managed object property

cfprFabricDceSwSrvPcStateQual

1.3.6.1.4.1.9.9.826.1.26.16.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPc:stateQual managed object property

cfprFabricDceSwSrvPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.16.1.18

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:DceSwSrvPc:switchId managed object property

cfprFabricDceSwSrvPcTransport

1.3.6.1.4.1.9.9.826.1.26.16.1.19

CfprFabricDceSwSrvPcTransport · BITS

Cisco Firepower fabric:DceSwSrvPc:transport managed object property

cfprFabricDceSwSrvPcType

1.3.6.1.4.1.9.9.826.1.26.16.1.20

CfprFabricSwSrvPcType · BITS

Cisco Firepower fabric:DceSwSrvPc:type managed object property

cfprFabricDceSwSrvPcEpTable

1.3.6.1.4.1.9.9.826.1.26.17

Index: cfprFabricDceSwSrvPcEpInstanceId

Cisco Firepower fabric:DceSwSrvPcEp managed object table

cfprFabricDceSwSrvPcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.17.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricDceSwSrvPcEpDnData

1.3.6.1.4.1.9.9.826.1.26.17.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:DceSwSrvPcEp:dn managed object property

cfprFabricDceSwSrvPcEpRn

1.3.6.1.4.1.9.9.826.1.26.17.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPcEp:rn managed object property

cfprFabricDceSwSrvPcEpAdminState

1.3.6.1.4.1.9.9.826.1.26.17.1.4

CfprFabricInternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:adminState managed object property

cfprFabricDceSwSrvPcEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.17.1.5

Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:aggrPortId managed object property

cfprFabricDceSwSrvPcEpChassisId

1.3.6.1.4.1.9.9.826.1.26.17.1.6

Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:chassisId managed object property

cfprFabricDceSwSrvPcEpEpDn

1.3.6.1.4.1.9.9.826.1.26.17.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPcEp:epDn managed object property

cfprFabricDceSwSrvPcEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.17.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:DceSwSrvPcEp:fltAggr managed object property

cfprFabricDceSwSrvPcEpIfRole

1.3.6.1.4.1.9.9.826.1.26.17.1.9

CfprFabricSwSrvEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:ifRole managed object property

cfprFabricDceSwSrvPcEpIfType

1.3.6.1.4.1.9.9.826.1.26.17.1.10

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:ifType managed object property

cfprFabricDceSwSrvPcEpLicGP

1.3.6.1.4.1.9.9.826.1.26.17.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:DceSwSrvPcEp:licGP managed object property

cfprFabricDceSwSrvPcEpLicState

1.3.6.1.4.1.9.9.826.1.26.17.1.12

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:licState managed object property

cfprFabricDceSwSrvPcEpLocale

1.3.6.1.4.1.9.9.826.1.26.17.1.13

CfprFabricInternalEpLocale · BITS

Cisco Firepower fabric:DceSwSrvPcEp:locale managed object property

cfprFabricDceSwSrvPcEpMembership

1.3.6.1.4.1.9.9.826.1.26.17.1.14

CfprFabricMembershipStatus1 = down2 = up3 = hotStandby4 = suspended5 = individual6 = moduleRemoved7 = incompatibleSpeed8 = unknown · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:membership managed object property

cfprFabricDceSwSrvPcEpName

1.3.6.1.4.1.9.9.826.1.26.17.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPcEp:name managed object property

cfprFabricDceSwSrvPcEpOperState

1.3.6.1.4.1.9.9.826.1.26.17.1.16

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:operState managed object property

cfprFabricDceSwSrvPcEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.17.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPcEp:operStateReason managed object property

cfprFabricDceSwSrvPcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.17.1.18

Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:peerAggrPortId managed object property

cfprFabricDceSwSrvPcEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.17.1.19

Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:peerChassisId managed object property

cfprFabricDceSwSrvPcEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.17.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPcEp:peerDn managed object property

cfprFabricDceSwSrvPcEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.17.1.21

Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:peerPortId managed object property

cfprFabricDceSwSrvPcEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.17.1.22

Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:peerSlotId managed object property

cfprFabricDceSwSrvPcEpPortId

1.3.6.1.4.1.9.9.826.1.26.17.1.23

CfprFabricDceSwSrvPcEpPortId (1..48) · Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:portId managed object property

cfprFabricDceSwSrvPcEpSlotId

1.3.6.1.4.1.9.9.826.1.26.17.1.24

CfprFabricDceSwSrvPcEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:DceSwSrvPcEp:slotId managed object property

cfprFabricDceSwSrvPcEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.17.1.25

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:DceSwSrvPcEp:switchId managed object property

cfprFabricDceSwSrvPcEpTransport

1.3.6.1.4.1.9.9.826.1.26.17.1.26

CfprFabricADceSwSrvEpTransport · BITS

Cisco Firepower fabric:DceSwSrvPcEp:transport managed object property

cfprFabricDceSwSrvPcEpType

1.3.6.1.4.1.9.9.826.1.26.17.1.27

CfprFabricSwSrvEpType · BITS

Cisco Firepower fabric:DceSwSrvPcEp:type managed object property

cfprFabricDceSwSrvPcEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.17.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:DceSwSrvPcEp:usrLbl managed object property

cfprFabricEpTable

1.3.6.1.4.1.9.9.826.1.26.18

Index: cfprFabricEpInstanceId

Cisco Firepower fabric:Ep managed object table

cfprFabricEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.18.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEpDn

1.3.6.1.4.1.9.9.826.1.26.18.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Ep:dn managed object property

cfprFabricEpRn

1.3.6.1.4.1.9.9.826.1.26.18.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Ep:rn managed object property

cfprFabricEpMgrTable

1.3.6.1.4.1.9.9.826.1.26.19

Index: cfprFabricEpMgrInstanceId

Cisco Firepower fabric:EpMgr managed object table

cfprFabricEpMgrInstanceId

1.3.6.1.4.1.9.9.826.1.26.19.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEpMgrDn

1.3.6.1.4.1.9.9.826.1.26.19.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EpMgr:dn managed object property

cfprFabricEpMgrRn

1.3.6.1.4.1.9.9.826.1.26.19.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:rn managed object property

cfprFabricEpMgrConfMode

1.3.6.1.4.1.9.9.826.1.26.19.1.4

CfprFabricConfMode0 = none1 = logicalConfigInvalid2 = validatingConf3 = applyPhysTrans4 = confSwitch · Integer32

Cisco Firepower fabric:EpMgr:confMode managed object property

cfprFabricEpMgrConfQual

1.3.6.1.4.1.9.9.826.1.26.19.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:confQual managed object property

cfprFabricEpMgrConfState

1.3.6.1.4.1.9.9.826.1.26.19.1.6

CfprFabricConfState0 = ok1 = logicalConfigInvalid · Integer32

Cisco Firepower fabric:EpMgr:confState managed object property

cfprFabricEpMgrFltAggr

1.3.6.1.4.1.9.9.826.1.26.19.1.7

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EpMgr:fltAggr managed object property

cfprFabricEpMgrFsmDescr

1.3.6.1.4.1.9.9.826.1.26.19.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:fsmDescr managed object property

cfprFabricEpMgrFsmFlags

1.3.6.1.4.1.9.9.826.1.26.19.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:fsmFlags managed object property

cfprFabricEpMgrFsmPrev

1.3.6.1.4.1.9.9.826.1.26.19.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:fsmPrev managed object property

cfprFabricEpMgrFsmProgr

1.3.6.1.4.1.9.9.826.1.26.19.1.11

Gauge32

Cisco Firepower fabric:EpMgr:fsmProgr managed object property

cfprFabricEpMgrFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.26.19.1.12

Gauge32

Cisco Firepower fabric:EpMgr:fsmRmtInvErrCode managed object property

cfprFabricEpMgrFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.26.19.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:fsmRmtInvErrDescr managed object property

cfprFabricEpMgrFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.26.19.1.14

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:EpMgr:fsmRmtInvRslt managed object property

cfprFabricEpMgrFsmStageDescr

1.3.6.1.4.1.9.9.826.1.26.19.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:fsmStageDescr managed object property

cfprFabricEpMgrFsmStamp

1.3.6.1.4.1.9.9.826.1.26.19.1.16

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:EpMgr:fsmStamp managed object property

cfprFabricEpMgrFsmStatus

1.3.6.1.4.1.9.9.826.1.26.19.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgr:fsmStatus managed object property

cfprFabricEpMgrFsmTry

1.3.6.1.4.1.9.9.826.1.26.19.1.18

Gauge32

Cisco Firepower fabric:EpMgr:fsmTry managed object property

cfprFabricEpMgrId

1.3.6.1.4.1.9.9.826.1.26.19.1.19

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EpMgr:id managed object property

cfprFabricEpMgrFsmTable

1.3.6.1.4.1.9.9.826.1.26.20

Index: cfprFabricEpMgrFsmInstanceId

Cisco Firepower fabric:EpMgrFsm managed object table

cfprFabricEpMgrFsmInstanceId

1.3.6.1.4.1.9.9.826.1.26.20.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEpMgrFsmDn

1.3.6.1.4.1.9.9.826.1.26.20.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EpMgrFsm:dn managed object property

cfprFabricEpMgrFsmRn

1.3.6.1.4.1.9.9.826.1.26.20.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgrFsm:rn managed object property

cfprFabricEpMgrFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.26.20.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:EpMgrFsm:completionTime managed object property

cfprFabricEpMgrFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.26.20.1.5

CfprFabricEpMgrFsmCurrentFsm0 = nop1113 = configure · Integer32

Cisco Firepower fabric:EpMgrFsm:currentFsm managed object property

cfprFabricEpMgrFsmDescrData

1.3.6.1.4.1.9.9.826.1.26.20.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgrFsm:descr managed object property

cfprFabricEpMgrFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.26.20.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:EpMgrFsm:fsmStatus managed object property

cfprFabricEpMgrFsmProgress

1.3.6.1.4.1.9.9.826.1.26.20.1.8

Gauge32

Cisco Firepower fabric:EpMgrFsm:progress managed object property

cfprFabricEpMgrFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.26.20.1.9

Gauge32

Cisco Firepower fabric:EpMgrFsm:rmtErrCode managed object property

cfprFabricEpMgrFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.26.20.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgrFsm:rmtErrDescr managed object property

cfprFabricEpMgrFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.26.20.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:EpMgrFsm:rmtRslt managed object property

cfprFabricEpMgrFsmStageTable

1.3.6.1.4.1.9.9.826.1.26.21

Index: cfprFabricEpMgrFsmStageInstanceId

Cisco Firepower fabric:EpMgrFsmStage managed object table

cfprFabricEpMgrFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.26.21.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEpMgrFsmStageDn

1.3.6.1.4.1.9.9.826.1.26.21.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EpMgrFsmStage:dn managed object property

cfprFabricEpMgrFsmStageRn

1.3.6.1.4.1.9.9.826.1.26.21.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgrFsmStage:rn managed object property

cfprFabricEpMgrFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.26.21.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgrFsmStage:descr managed object property

cfprFabricEpMgrFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.26.21.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:EpMgrFsmStage:lastUpdateTime managed object property

cfprFabricEpMgrFsmStageName

1.3.6.1.4.1.9.9.826.1.26.21.1.6

CfprFabricEpMgrFsmStageName0 = nop1113 = configureBegin1114 = configureValidateConfiguration1115 = configureApplyPhysical1116 = configureWaitOnPhys1117 = configureApplyConfig1144 = configureFail1145 = configureSuccess · Integer32

Cisco Firepower fabric:EpMgrFsmStage:name managed object property

cfprFabricEpMgrFsmStageOrder

1.3.6.1.4.1.9.9.826.1.26.21.1.7

Gauge32

Cisco Firepower fabric:EpMgrFsmStage:order managed object property

cfprFabricEpMgrFsmStageRetry

1.3.6.1.4.1.9.9.826.1.26.21.1.8

Gauge32

Cisco Firepower fabric:EpMgrFsmStage:retry managed object property

cfprFabricEpMgrFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.26.21.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:EpMgrFsmStage:stageStatus managed object property

cfprFabricEpMgrFsmTaskTable

1.3.6.1.4.1.9.9.826.1.26.22

Index: cfprFabricEpMgrFsmTaskInstanceId

Cisco Firepower fabric:EpMgrFsmTask managed object table

cfprFabricEpMgrFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.26.22.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEpMgrFsmTaskDn

1.3.6.1.4.1.9.9.826.1.26.22.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EpMgrFsmTask:dn managed object property

cfprFabricEpMgrFsmTaskRn

1.3.6.1.4.1.9.9.826.1.26.22.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EpMgrFsmTask:rn managed object property

cfprFabricEpMgrFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.26.22.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower fabric:EpMgrFsmTask:completion managed object property

cfprFabricEpMgrFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.26.22.1.5

CfprFabricEpMgrFsmTaskFlags · BITS

Cisco Firepower fabric:EpMgrFsmTask:flags managed object property

cfprFabricEpMgrFsmTaskItem

1.3.6.1.4.1.9.9.826.1.26.22.1.6

CfprFabricEpMgrFsmTaskItem0 = nop1113 = configure · Integer32

Cisco Firepower fabric:EpMgrFsmTask:item managed object property

cfprFabricEpMgrFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.26.22.1.7

Gauge32

Cisco Firepower fabric:EpMgrFsmTask:seqId managed object property

cfprFabricEthEstcTable

1.3.6.1.4.1.9.9.826.1.26.23

Index: cfprFabricEthEstcInstanceId

Cisco Firepower fabric:EthEstc managed object table

cfprFabricEthEstcInstanceId

1.3.6.1.4.1.9.9.826.1.26.23.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthEstcDn

1.3.6.1.4.1.9.9.826.1.26.23.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthEstc:dn managed object property

cfprFabricEthEstcRn

1.3.6.1.4.1.9.9.826.1.26.23.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstc:rn managed object property

cfprFabricEthEstcId

1.3.6.1.4.1.9.9.826.1.26.23.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthEstc:id managed object property

cfprFabricEthEstcLocale

1.3.6.1.4.1.9.9.826.1.26.23.1.5

CfprFabricExternalLocale · BITS

Cisco Firepower fabric:EthEstc:locale managed object property

cfprFabricEthEstcName

1.3.6.1.4.1.9.9.826.1.26.23.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstc:name managed object property

cfprFabricEthEstcTransport

1.3.6.1.4.1.9.9.826.1.26.23.1.7

CfprFabricEthEstcTransport · BITS

Cisco Firepower fabric:EthEstc:transport managed object property

cfprFabricEthEstcType

1.3.6.1.4.1.9.9.826.1.26.23.1.8

CfprFabricEthEstcType · BITS

Cisco Firepower fabric:EthEstc:type managed object property

cfprFabricEthEstcCloudTable

1.3.6.1.4.1.9.9.826.1.26.24

Index: cfprFabricEthEstcCloudInstanceId

Cisco Firepower fabric:EthEstcCloud managed object table

cfprFabricEthEstcCloudInstanceId

1.3.6.1.4.1.9.9.826.1.26.24.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthEstcCloudDn

1.3.6.1.4.1.9.9.826.1.26.24.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthEstcCloud:dn managed object property

cfprFabricEthEstcCloudRn

1.3.6.1.4.1.9.9.826.1.26.24.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcCloud:rn managed object property

cfprFabricEthEstcEpTable

1.3.6.1.4.1.9.9.826.1.26.25

Index: cfprFabricEthEstcEpInstanceId

Cisco Firepower fabric:EthEstcEp managed object table

cfprFabricEthEstcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.25.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthEstcEpDn

1.3.6.1.4.1.9.9.826.1.26.25.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthEstcEp:dn managed object property

cfprFabricEthEstcEpRn

1.3.6.1.4.1.9.9.826.1.26.25.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:rn managed object property

cfprFabricEthEstcEpAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.25.1.4

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:EthEstcEp:adminSpeed managed object property

cfprFabricEthEstcEpAdminState

1.3.6.1.4.1.9.9.826.1.26.25.1.5

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthEstcEp:adminState managed object property

cfprFabricEthEstcEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.25.1.6

Gauge32

Cisco Firepower fabric:EthEstcEp:aggrPortId managed object property

cfprFabricEthEstcEpChassisId

1.3.6.1.4.1.9.9.826.1.26.25.1.7

Gauge32

Cisco Firepower fabric:EthEstcEp:chassisId managed object property

cfprFabricEthEstcEpConfigState

1.3.6.1.4.1.9.9.826.1.26.25.1.8

CfprFabricConfigState1 = applied2 = inconsistent · Integer32

Cisco Firepower fabric:EthEstcEp:configState managed object property

cfprFabricEthEstcEpEpDn

1.3.6.1.4.1.9.9.826.1.26.25.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:epDn managed object property

cfprFabricEthEstcEpFlowCtrlPolicy

1.3.6.1.4.1.9.9.826.1.26.25.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:flowCtrlPolicy managed object property

cfprFabricEthEstcEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.25.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthEstcEp:fltAggr managed object property

cfprFabricEthEstcEpIfRole

1.3.6.1.4.1.9.9.826.1.26.25.1.12

CfprFabricAEthEstcEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthEstcEp:ifRole managed object property

cfprFabricEthEstcEpIfType

1.3.6.1.4.1.9.9.826.1.26.25.1.13

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthEstcEp:ifType managed object property

cfprFabricEthEstcEpLicGP

1.3.6.1.4.1.9.9.826.1.26.25.1.14

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthEstcEp:licGP managed object property

cfprFabricEthEstcEpLicState

1.3.6.1.4.1.9.9.826.1.26.25.1.15

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthEstcEp:licState managed object property

cfprFabricEthEstcEpLocale

1.3.6.1.4.1.9.9.826.1.26.25.1.16

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthEstcEp:locale managed object property

cfprFabricEthEstcEpName

1.3.6.1.4.1.9.9.826.1.26.25.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:name managed object property

cfprFabricEthEstcEpNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.25.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:nwCtrlPolicyName managed object property

cfprFabricEthEstcEpOperNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.25.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:operNwCtrlPolicyName managed object property

cfprFabricEthEstcEpOperPortMode

1.3.6.1.4.1.9.9.826.1.26.25.1.20

CfprFabricEthEstcOperPortMode1 = regularTrunk2 = regularAccess3 = promiscuousTrunk4 = promiscuousAccess · Integer32

Cisco Firepower fabric:EthEstcEp:operPortMode managed object property

cfprFabricEthEstcEpOperState

1.3.6.1.4.1.9.9.826.1.26.25.1.21

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthEstcEp:operState managed object property

cfprFabricEthEstcEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.25.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:operStateReason managed object property

cfprFabricEthEstcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.25.1.23

Gauge32

Cisco Firepower fabric:EthEstcEp:peerAggrPortId managed object property

cfprFabricEthEstcEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.25.1.24

Gauge32

Cisco Firepower fabric:EthEstcEp:peerChassisId managed object property

cfprFabricEthEstcEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.25.1.25

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:peerDn managed object property

cfprFabricEthEstcEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.25.1.26

Gauge32

Cisco Firepower fabric:EthEstcEp:peerPortId managed object property

cfprFabricEthEstcEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.25.1.27

Gauge32

Cisco Firepower fabric:EthEstcEp:peerSlotId managed object property

cfprFabricEthEstcEpPinGroupName

1.3.6.1.4.1.9.9.826.1.26.25.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:pinGroupName managed object property

cfprFabricEthEstcEpPortId

1.3.6.1.4.1.9.9.826.1.26.25.1.29

CfprFabricEthEstcEpPortId (1..48) · Gauge32

Cisco Firepower fabric:EthEstcEp:portId managed object property

cfprFabricEthEstcEpPortMode

1.3.6.1.4.1.9.9.826.1.26.25.1.30

CfprFabricEthEstcPortMode1 = trunk2 = access · Integer32

Cisco Firepower fabric:EthEstcEp:portMode managed object property

cfprFabricEthEstcEpPrio

1.3.6.1.4.1.9.9.826.1.26.25.1.31

CfprFabricEthEstcEpPrio1 = fc2 = platinum3 = gold4 = silver5 = bronze6 = bestEffort · Integer32

Cisco Firepower fabric:EthEstcEp:prio managed object property

cfprFabricEthEstcEpSlotId

1.3.6.1.4.1.9.9.826.1.26.25.1.32

CfprFabricEthEstcEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:EthEstcEp:slotId managed object property

cfprFabricEthEstcEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.25.1.33

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthEstcEp:switchId managed object property

cfprFabricEthEstcEpTransport

1.3.6.1.4.1.9.9.826.1.26.25.1.34

CfprFabricEthEstcEpTransport · BITS

Cisco Firepower fabric:EthEstcEp:transport managed object property

cfprFabricEthEstcEpType

1.3.6.1.4.1.9.9.826.1.26.25.1.35

CfprFabricEthEstcEpType · BITS

Cisco Firepower fabric:EthEstcEp:type managed object property

cfprFabricEthEstcEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.25.1.36

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcEp:usrLbl managed object property

cfprFabricEthEstcEpWarnings

1.3.6.1.4.1.9.9.826.1.26.25.1.37

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthEstcEp:warnings managed object property

cfprFabricEthEstcPcTable

1.3.6.1.4.1.9.9.826.1.26.26

Index: cfprFabricEthEstcPcInstanceId

Cisco Firepower fabric:EthEstcPc managed object table

cfprFabricEthEstcPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.26.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthEstcPcDn

1.3.6.1.4.1.9.9.826.1.26.26.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthEstcPc:dn managed object property

cfprFabricEthEstcPcRn

1.3.6.1.4.1.9.9.826.1.26.26.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:rn managed object property

cfprFabricEthEstcPcAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.26.1.4

CfprPortEthAdminSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps · Integer32

Cisco Firepower fabric:EthEstcPc:adminSpeed managed object property

cfprFabricEthEstcPcAdminState

1.3.6.1.4.1.9.9.826.1.26.26.1.5

CfprFabricCIoEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthEstcPc:adminState managed object property

cfprFabricEthEstcPcDescr

1.3.6.1.4.1.9.9.826.1.26.26.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:descr managed object property

cfprFabricEthEstcPcEpDn

1.3.6.1.4.1.9.9.826.1.26.26.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:epDn managed object property

cfprFabricEthEstcPcFlowCtrlPolicy

1.3.6.1.4.1.9.9.826.1.26.26.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:flowCtrlPolicy managed object property

cfprFabricEthEstcPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.26.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthEstcPc:fltAggr managed object property

cfprFabricEthEstcPcIfRole

1.3.6.1.4.1.9.9.826.1.26.26.1.10

CfprFabricEstcPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthEstcPc:ifRole managed object property

cfprFabricEthEstcPcIfType

1.3.6.1.4.1.9.9.826.1.26.26.1.11

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthEstcPc:ifType managed object property

cfprFabricEthEstcPcLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.26.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:lacpPolicyName managed object property

cfprFabricEthEstcPcLocale

1.3.6.1.4.1.9.9.826.1.26.26.1.13

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:EthEstcPc:locale managed object property

cfprFabricEthEstcPcName

1.3.6.1.4.1.9.9.826.1.26.26.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:name managed object property

cfprFabricEthEstcPcNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.26.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:nwCtrlPolicyName managed object property

cfprFabricEthEstcPcOperLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.26.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:operLacpPolicyName managed object property

cfprFabricEthEstcPcOperNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.26.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:operNwCtrlPolicyName managed object property

cfprFabricEthEstcPcOperSpeed

1.3.6.1.4.1.9.9.826.1.26.26.1.18

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:EthEstcPc:operSpeed managed object property

cfprFabricEthEstcPcOperState

1.3.6.1.4.1.9.9.826.1.26.26.1.19

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:EthEstcPc:operState managed object property

cfprFabricEthEstcPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.26.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:peerDn managed object property

cfprFabricEthEstcPcPinGroupName

1.3.6.1.4.1.9.9.826.1.26.26.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:pinGroupName managed object property

cfprFabricEthEstcPcPortId

1.3.6.1.4.1.9.9.826.1.26.26.1.22

Gauge32

Cisco Firepower fabric:EthEstcPc:portId managed object property

cfprFabricEthEstcPcPortMode

1.3.6.1.4.1.9.9.826.1.26.26.1.23

CfprFabricEthEstcPortMode1 = trunk2 = access · Integer32

Cisco Firepower fabric:EthEstcPc:portMode managed object property

cfprFabricEthEstcPcPrio

1.3.6.1.4.1.9.9.826.1.26.26.1.24

CfprQosPriority1 = fc2 = platinum3 = gold4 = silver5 = bronze6 = bestEffort · Integer32

Cisco Firepower fabric:EthEstcPc:prio managed object property

cfprFabricEthEstcPcProtocol

1.3.6.1.4.1.9.9.826.1.26.26.1.25

CfprFabricEthPcProtocol1 = static2 = lacp · Integer32

Cisco Firepower fabric:EthEstcPc:protocol managed object property

cfprFabricEthEstcPcStateQual

1.3.6.1.4.1.9.9.826.1.26.26.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPc:stateQual managed object property

cfprFabricEthEstcPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.26.1.27

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthEstcPc:switchId managed object property

cfprFabricEthEstcPcTransport

1.3.6.1.4.1.9.9.826.1.26.26.1.28

CfprFabricEthEstcPcTransport · BITS

Cisco Firepower fabric:EthEstcPc:transport managed object property

cfprFabricEthEstcPcType

1.3.6.1.4.1.9.9.826.1.26.26.1.29

CfprFabricEstcPcType · BITS

Cisco Firepower fabric:EthEstcPc:type managed object property

cfprFabricEthEstcPcWarnings

1.3.6.1.4.1.9.9.826.1.26.26.1.30

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthEstcPc:warnings managed object property

cfprFabricEthEstcPcEpTable

1.3.6.1.4.1.9.9.826.1.26.27

Index: cfprFabricEthEstcPcEpInstanceId

Cisco Firepower fabric:EthEstcPcEp managed object table

cfprFabricEthEstcPcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.27.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthEstcPcEpDnData

1.3.6.1.4.1.9.9.826.1.26.27.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthEstcPcEp:dn managed object property

cfprFabricEthEstcPcEpRn

1.3.6.1.4.1.9.9.826.1.26.27.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPcEp:rn managed object property

cfprFabricEthEstcPcEpAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.27.1.4

CfprPortSpeed0 = indeterminate1 = n1gbps2 = n2gbps3 = n4gbps4 = n8gbps5 = auto · Integer32

Cisco Firepower fabric:EthEstcPcEp:adminSpeed managed object property

cfprFabricEthEstcPcEpAdminState

1.3.6.1.4.1.9.9.826.1.26.27.1.5

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthEstcPcEp:adminState managed object property

cfprFabricEthEstcPcEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.27.1.6

Gauge32

Cisco Firepower fabric:EthEstcPcEp:aggrPortId managed object property

cfprFabricEthEstcPcEpChassisId

1.3.6.1.4.1.9.9.826.1.26.27.1.7

Gauge32

Cisco Firepower fabric:EthEstcPcEp:chassisId managed object property

cfprFabricEthEstcPcEpConfigState

1.3.6.1.4.1.9.9.826.1.26.27.1.8

CfprFabricConfigState1 = applied2 = inconsistent · Integer32

Cisco Firepower fabric:EthEstcPcEp:configState managed object property

cfprFabricEthEstcPcEpEpDn

1.3.6.1.4.1.9.9.826.1.26.27.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPcEp:epDn managed object property

cfprFabricEthEstcPcEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.27.1.10

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthEstcPcEp:fltAggr managed object property

cfprFabricEthEstcPcEpIfRole

1.3.6.1.4.1.9.9.826.1.26.27.1.11

CfprFabricAEthEstcEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthEstcPcEp:ifRole managed object property

cfprFabricEthEstcPcEpIfType

1.3.6.1.4.1.9.9.826.1.26.27.1.12

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthEstcPcEp:ifType managed object property

cfprFabricEthEstcPcEpLicGP

1.3.6.1.4.1.9.9.826.1.26.27.1.13

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthEstcPcEp:licGP managed object property

cfprFabricEthEstcPcEpLicState

1.3.6.1.4.1.9.9.826.1.26.27.1.14

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthEstcPcEp:licState managed object property

cfprFabricEthEstcPcEpLocale

1.3.6.1.4.1.9.9.826.1.26.27.1.15

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthEstcPcEp:locale managed object property

cfprFabricEthEstcPcEpMembership

1.3.6.1.4.1.9.9.826.1.26.27.1.16

CfprFabricMembershipStatus1 = down2 = up3 = hotStandby4 = suspended5 = individual6 = moduleRemoved7 = incompatibleSpeed8 = unknown · Integer32

Cisco Firepower fabric:EthEstcPcEp:membership managed object property

cfprFabricEthEstcPcEpName

1.3.6.1.4.1.9.9.826.1.26.27.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPcEp:name managed object property

cfprFabricEthEstcPcEpOperState

1.3.6.1.4.1.9.9.826.1.26.27.1.18

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthEstcPcEp:operState managed object property

cfprFabricEthEstcPcEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.27.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPcEp:operStateReason managed object property

cfprFabricEthEstcPcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.27.1.20

Gauge32

Cisco Firepower fabric:EthEstcPcEp:peerAggrPortId managed object property

cfprFabricEthEstcPcEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.27.1.21

Gauge32

Cisco Firepower fabric:EthEstcPcEp:peerChassisId managed object property

cfprFabricEthEstcPcEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.27.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPcEp:peerDn managed object property

cfprFabricEthEstcPcEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.27.1.23

Gauge32

Cisco Firepower fabric:EthEstcPcEp:peerPortId managed object property

cfprFabricEthEstcPcEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.27.1.24

Gauge32

Cisco Firepower fabric:EthEstcPcEp:peerSlotId managed object property

cfprFabricEthEstcPcEpPortId

1.3.6.1.4.1.9.9.826.1.26.27.1.25

CfprFabricEthEstcPcEpPortId (1..48) · Gauge32

Cisco Firepower fabric:EthEstcPcEp:portId managed object property

cfprFabricEthEstcPcEpSlotId

1.3.6.1.4.1.9.9.826.1.26.27.1.26

CfprFabricEthEstcPcEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:EthEstcPcEp:slotId managed object property

cfprFabricEthEstcPcEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.27.1.27

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthEstcPcEp:switchId managed object property

cfprFabricEthEstcPcEpTransport

1.3.6.1.4.1.9.9.826.1.26.27.1.28

CfprFabricAEthEstcEpTransport · BITS

Cisco Firepower fabric:EthEstcPcEp:transport managed object property

cfprFabricEthEstcPcEpType

1.3.6.1.4.1.9.9.826.1.26.27.1.29

CfprFabricAEthEstcEpType · BITS

Cisco Firepower fabric:EthEstcPcEp:type managed object property

cfprFabricEthEstcPcEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.27.1.30

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthEstcPcEp:usrLbl managed object property

cfprFabricEthEstcPcEpWarnings

1.3.6.1.4.1.9.9.826.1.26.27.1.31

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthEstcPcEp:warnings managed object property

cfprFabricEthLanTable

1.3.6.1.4.1.9.9.826.1.26.29

Index: cfprFabricEthLanInstanceId

Cisco Firepower fabric:EthLan managed object table

cfprFabricEthLanInstanceId

1.3.6.1.4.1.9.9.826.1.26.29.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthLanDn

1.3.6.1.4.1.9.9.826.1.26.29.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthLan:dn managed object property

cfprFabricEthLanRn

1.3.6.1.4.1.9.9.826.1.26.29.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLan:rn managed object property

cfprFabricEthLanId

1.3.6.1.4.1.9.9.826.1.26.29.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthLan:id managed object property

cfprFabricEthLanLocale

1.3.6.1.4.1.9.9.826.1.26.29.1.5

CfprFabricExternalLocale · BITS

Cisco Firepower fabric:EthLan:locale managed object property

cfprFabricEthLanName

1.3.6.1.4.1.9.9.826.1.26.29.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLan:name managed object property

cfprFabricEthLanTransport

1.3.6.1.4.1.9.9.826.1.26.29.1.7

CfprFabricEthLanTransport · BITS

Cisco Firepower fabric:EthLan:transport managed object property

cfprFabricEthLanType

1.3.6.1.4.1.9.9.826.1.26.29.1.8

CfprFabricLanType · BITS

Cisco Firepower fabric:EthLan:type managed object property

cfprFabricEthLanEpTable

1.3.6.1.4.1.9.9.826.1.26.30

Index: cfprFabricEthLanEpInstanceId

Cisco Firepower fabric:EthLanEp managed object table

cfprFabricEthLanEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.30.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthLanEpDn

1.3.6.1.4.1.9.9.826.1.26.30.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthLanEp:dn managed object property

cfprFabricEthLanEpRn

1.3.6.1.4.1.9.9.826.1.26.30.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:rn managed object property

cfprFabricEthLanEpAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.30.1.4

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:EthLanEp:adminSpeed managed object property

cfprFabricEthLanEpAdminState

1.3.6.1.4.1.9.9.826.1.26.30.1.5

CfprFabricEthLanEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanEp:adminState managed object property

cfprFabricEthLanEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.30.1.6

Gauge32

Cisco Firepower fabric:EthLanEp:aggrPortId managed object property

cfprFabricEthLanEpChassisId

1.3.6.1.4.1.9.9.826.1.26.30.1.7

Gauge32

Cisco Firepower fabric:EthLanEp:chassisId managed object property

cfprFabricEthLanEpDtagVlan

1.3.6.1.4.1.9.9.826.1.26.30.1.8

Gauge32

Cisco Firepower fabric:EthLanEp:dtagVlan managed object property

cfprFabricEthLanEpEpDn

1.3.6.1.4.1.9.9.826.1.26.30.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:epDn managed object property

cfprFabricEthLanEpEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.30.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:ethLinkProfileName managed object property

cfprFabricEthLanEpFlowCtrlPolicy

1.3.6.1.4.1.9.9.826.1.26.30.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:flowCtrlPolicy managed object property

cfprFabricEthLanEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.30.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthLanEp:fltAggr managed object property

cfprFabricEthLanEpIfRole

1.3.6.1.4.1.9.9.826.1.26.30.1.13

CfprFabricLanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthLanEp:ifRole managed object property

cfprFabricEthLanEpIfType

1.3.6.1.4.1.9.9.826.1.26.30.1.14

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthLanEp:ifType managed object property

cfprFabricEthLanEpLicGP

1.3.6.1.4.1.9.9.826.1.26.30.1.15

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthLanEp:licGP managed object property

cfprFabricEthLanEpLicState

1.3.6.1.4.1.9.9.826.1.26.30.1.16

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthLanEp:licState managed object property

cfprFabricEthLanEpLocale

1.3.6.1.4.1.9.9.826.1.26.30.1.17

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthLanEp:locale managed object property

cfprFabricEthLanEpName

1.3.6.1.4.1.9.9.826.1.26.30.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:name managed object property

cfprFabricEthLanEpOperEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.30.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:operEthLinkProfileName managed object property

cfprFabricEthLanEpOperState

1.3.6.1.4.1.9.9.826.1.26.30.1.21

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthLanEp:operState managed object property

cfprFabricEthLanEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.30.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:operStateReason managed object property

cfprFabricEthLanEpOverlappingVlans

1.3.6.1.4.1.9.9.826.1.26.30.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:overlappingVlans managed object property

cfprFabricEthLanEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.30.1.24

Gauge32

Cisco Firepower fabric:EthLanEp:peerAggrPortId managed object property

cfprFabricEthLanEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.30.1.25

Gauge32

Cisco Firepower fabric:EthLanEp:peerChassisId managed object property

cfprFabricEthLanEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.30.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:peerDn managed object property

cfprFabricEthLanEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.30.1.27

Gauge32

Cisco Firepower fabric:EthLanEp:peerPortId managed object property

cfprFabricEthLanEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.30.1.28

Gauge32

Cisco Firepower fabric:EthLanEp:peerSlotId managed object property

cfprFabricEthLanEpPortId

1.3.6.1.4.1.9.9.826.1.26.30.1.29

Gauge32

Cisco Firepower fabric:EthLanEp:portId managed object property

cfprFabricEthLanEpSlotId

1.3.6.1.4.1.9.9.826.1.26.30.1.30

Gauge32

Cisco Firepower fabric:EthLanEp:slotId managed object property

cfprFabricEthLanEpSsaPortType

1.3.6.1.4.1.9.9.826.1.26.30.1.31

CfprFabricSSAPortType0 = data1 = mgmt2 = cluster3 = firepowerEventing4 = virtualData5 = dataSharing · Integer32

Cisco Firepower fabric:EthLanEp:ssaPortType managed object property

cfprFabricEthLanEpSsaVlanId

1.3.6.1.4.1.9.9.826.1.26.30.1.32

Gauge32

Cisco Firepower fabric:EthLanEp:ssaVlanId managed object property

cfprFabricEthLanEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.30.1.33

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthLanEp:switchId managed object property

cfprFabricEthLanEpTransport

1.3.6.1.4.1.9.9.826.1.26.30.1.34

CfprFabricAEthLanEpTransport · BITS

Cisco Firepower fabric:EthLanEp:transport managed object property

cfprFabricEthLanEpType

1.3.6.1.4.1.9.9.826.1.26.30.1.35

CfprFabricLanEpType · BITS

Cisco Firepower fabric:EthLanEp:type managed object property

cfprFabricEthLanEpUdldOperState

1.3.6.1.4.1.9.9.826.1.26.30.1.36

CfprFabricUdldOperState0 = unknown1 = unidirectional2 = bidirectional3 = txRxLoop4 = mismatch5 = echoEmpty6 = adminDisabled · Integer32

Cisco Firepower fabric:EthLanEp:udldOperState managed object property

cfprFabricEthLanEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.30.1.37

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:usrLbl managed object property

cfprFabricEthLanEpVlanStatus

1.3.6.1.4.1.9.9.826.1.26.30.1.38

CfprFabricEthLanEpVlanStatus0 = ok1 = missingPrimary · Integer32

Cisco Firepower fabric:EthLanEp:vlanStatus managed object property

cfprFabricEthLanEpWarnings

1.3.6.1.4.1.9.9.826.1.26.30.1.39

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthLanEp:warnings managed object property

cfprFabricEthLanEpAdminDuplex

1.3.6.1.4.1.9.9.826.1.26.30.1.40

CfprPortDuplex1 = halfDuplex2 = fullDuplex4 = auto · Integer32

Cisco Firepower fabric:EthLanEp:adminDuplex managed object property

cfprFabricEthLanEpAllowSharing

1.3.6.1.4.1.9.9.826.1.26.30.1.41

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthLanEp:allowSharing managed object property

cfprFabricEthLanEpAllowedVlan

1.3.6.1.4.1.9.9.826.1.26.30.1.42

CfprFabricAllowedVlanType0 = all1 = untagged · Integer32

Cisco Firepower fabric:EthLanEp:allowedVlan managed object property

cfprFabricEthLanEpAutoNeg

1.3.6.1.4.1.9.9.826.1.26.30.1.43

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthLanEp:autoNeg managed object property

cfprFabricEthLanEpDescr

1.3.6.1.4.1.9.9.826.1.26.30.1.44

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:descr managed object property

cfprFabricEthLanEpHashAlg

1.3.6.1.4.1.9.9.826.1.26.30.1.45

CfprNhTpHashType0 = normal1 = twoTuple · Integer32

Cisco Firepower fabric:EthLanEp:hashAlg managed object property

cfprFabricEthLanEpInlinePeerDn

1.3.6.1.4.1.9.9.826.1.26.30.1.46

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:inlinePeerDn managed object property

cfprFabricEthLanEpInlinePeerName

1.3.6.1.4.1.9.9.826.1.26.30.1.47

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:inlinePeerName managed object property

cfprFabricEthLanEpInlineState

1.3.6.1.4.1.9.9.826.1.26.30.1.48

CfprFabricEthLanEpInlineState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanEp:inlineState managed object property

cfprFabricEthLanEpQosPrio

1.3.6.1.4.1.9.9.826.1.26.30.1.49

CfprFabricQosPrio0 = low1 = high · Integer32

Cisco Firepower fabric:EthLanEp:qosPrio managed object property

cfprFabricEthLanEpSpeedCap

1.3.6.1.4.1.9.9.826.1.26.30.1.50

CfprEquipmentEthPortSpeedCap · BITS

Cisco Firepower fabric:EthLanEp:speedCap managed object property

cfprFabricEthLanEpNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.30.1.51

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:nwCtrlPolicyName managed object property

cfprFabricEthLanEpOperNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.30.1.52

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanEp:operNwCtrlPolicyName managed object property

cfprFabricEthLanEpAllowAneg

1.3.6.1.4.1.9.9.826.1.26.30.1.53

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthLanEp:allowAneg managed object property

cfprFabricEthLanEpDebounceTime

1.3.6.1.4.1.9.9.826.1.26.30.1.54

Gauge32

Cisco Firepower fabric:EthLanEp:debounceTime managed object property

cfprFabricEthLanEpLastSvcStateDownReason

1.3.6.1.4.1.9.9.826.1.26.30.1.55

CfprFabricSvcStateDownReason0 = none1 = adminDown2 = bladeShutdown3 = bladeReboot4 = appOffline5 = appDisabled6 = appFailed7 = chassisReboot · Integer32

Cisco Firepower fabric:EthLanEp:lastSvcStateDownReason managed object property

cfprFabricEthLanEpServiceState

1.3.6.1.4.1.9.9.826.1.26.30.1.56

CfprFabricEthLanEpServiceState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanEp:serviceState managed object property

cfprFabricEthLanPcTable

1.3.6.1.4.1.9.9.826.1.26.32

Index: cfprFabricEthLanPcInstanceId

Cisco Firepower fabric:EthLanPc managed object table

cfprFabricEthLanPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.32.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthLanPcDn

1.3.6.1.4.1.9.9.826.1.26.32.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthLanPc:dn managed object property

cfprFabricEthLanPcRn

1.3.6.1.4.1.9.9.826.1.26.32.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:rn managed object property

cfprFabricEthLanPcAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.32.1.4

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:EthLanPc:adminSpeed managed object property

cfprFabricEthLanPcAdminState

1.3.6.1.4.1.9.9.826.1.26.32.1.5

CfprFabricEthLanPcAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanPc:adminState managed object property

cfprFabricEthLanPcBandwidth

1.3.6.1.4.1.9.9.826.1.26.32.1.6

Gauge32

Cisco Firepower fabric:EthLanPc:bandwidth managed object property

cfprFabricEthLanPcClusterName

1.3.6.1.4.1.9.9.826.1.26.32.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:clusterName managed object property

cfprFabricEthLanPcDescr

1.3.6.1.4.1.9.9.826.1.26.32.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:descr managed object property

cfprFabricEthLanPcDtagVlan

1.3.6.1.4.1.9.9.826.1.26.32.1.9

Gauge32

Cisco Firepower fabric:EthLanPc:dtagVlan managed object property

cfprFabricEthLanPcEpDn

1.3.6.1.4.1.9.9.826.1.26.32.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:epDn managed object property

cfprFabricEthLanPcFlowCtrlPolicy

1.3.6.1.4.1.9.9.826.1.26.32.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:flowCtrlPolicy managed object property

cfprFabricEthLanPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.32.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthLanPc:fltAggr managed object property

cfprFabricEthLanPcIfRole

1.3.6.1.4.1.9.9.826.1.26.32.1.13

CfprFabricLanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthLanPc:ifRole managed object property

cfprFabricEthLanPcIfType

1.3.6.1.4.1.9.9.826.1.26.32.1.14

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthLanPc:ifType managed object property

cfprFabricEthLanPcLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.32.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:lacpPolicyName managed object property

cfprFabricEthLanPcLocale

1.3.6.1.4.1.9.9.826.1.26.32.1.16

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:EthLanPc:locale managed object property

cfprFabricEthLanPcName

1.3.6.1.4.1.9.9.826.1.26.32.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:name managed object property

cfprFabricEthLanPcOperLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.32.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:operLacpPolicyName managed object property

cfprFabricEthLanPcOperSpeed

1.3.6.1.4.1.9.9.826.1.26.32.1.20

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:EthLanPc:operSpeed managed object property

cfprFabricEthLanPcOperState

1.3.6.1.4.1.9.9.826.1.26.32.1.21

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:EthLanPc:operState managed object property

cfprFabricEthLanPcOverlappingVlans

1.3.6.1.4.1.9.9.826.1.26.32.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:overlappingVlans managed object property

cfprFabricEthLanPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.32.1.23

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:peerDn managed object property

cfprFabricEthLanPcPortId

1.3.6.1.4.1.9.9.826.1.26.32.1.24

Gauge32

Cisco Firepower fabric:EthLanPc:portId managed object property

cfprFabricEthLanPcSpannedCluster

1.3.6.1.4.1.9.9.826.1.26.32.1.25

CfprFabricSpannedCluster1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanPc:spannedCluster managed object property

cfprFabricEthLanPcSsaPortType

1.3.6.1.4.1.9.9.826.1.26.32.1.26

CfprFabricSSAPortType0 = data1 = mgmt2 = cluster3 = firepowerEventing4 = virtualData5 = dataSharing · Integer32

Cisco Firepower fabric:EthLanPc:ssaPortType managed object property

cfprFabricEthLanPcSsaVlanId

1.3.6.1.4.1.9.9.826.1.26.32.1.27

Gauge32

Cisco Firepower fabric:EthLanPc:ssaVlanId managed object property

cfprFabricEthLanPcStateQual

1.3.6.1.4.1.9.9.826.1.26.32.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:stateQual managed object property

cfprFabricEthLanPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.32.1.29

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthLanPc:switchId managed object property

cfprFabricEthLanPcTransport

1.3.6.1.4.1.9.9.826.1.26.32.1.30

CfprFabricEthLanPcTransport · BITS

Cisco Firepower fabric:EthLanPc:transport managed object property

cfprFabricEthLanPcType

1.3.6.1.4.1.9.9.826.1.26.32.1.31

CfprFabricLanPcType · BITS

Cisco Firepower fabric:EthLanPc:type managed object property

cfprFabricEthLanPcVlanStatus

1.3.6.1.4.1.9.9.826.1.26.32.1.32

CfprFabricEthLanPcVlanStatus0 = ok1 = missingPrimary · Integer32

Cisco Firepower fabric:EthLanPc:vlanStatus managed object property

cfprFabricEthLanPcWarnings

1.3.6.1.4.1.9.9.826.1.26.32.1.33

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthLanPc:warnings managed object property

cfprFabricEthLanPcCluChassisId

1.3.6.1.4.1.9.9.826.1.26.32.1.34

Gauge32

Cisco Firepower fabric:EthLanPc:cluChassisId managed object property

cfprFabricEthLanPcLacpDetach

1.3.6.1.4.1.9.9.826.1.26.32.1.35

CfprFabricEthLanPcLacpDetach1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanPc:lacpDetach managed object property

cfprFabricEthLanPcAdminDuplex

1.3.6.1.4.1.9.9.826.1.26.32.1.36

CfprPortDuplex1 = halfDuplex2 = fullDuplex4 = auto · Integer32

Cisco Firepower fabric:EthLanPc:adminDuplex managed object property

cfprFabricEthLanPcAllowSharing

1.3.6.1.4.1.9.9.826.1.26.32.1.37

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthLanPc:allowSharing managed object property

cfprFabricEthLanPcAllowedVlan

1.3.6.1.4.1.9.9.826.1.26.32.1.38

CfprFabricAllowedVlanType0 = all1 = untagged · Integer32

Cisco Firepower fabric:EthLanPc:allowedVlan managed object property

cfprFabricEthLanPcAutoNeg

1.3.6.1.4.1.9.9.826.1.26.32.1.39

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthLanPc:autoNeg managed object property

cfprFabricEthLanPcHashAlg

1.3.6.1.4.1.9.9.826.1.26.32.1.40

CfprNhTpHashType0 = normal1 = twoTuple · Integer32

Cisco Firepower fabric:EthLanPc:hashAlg managed object property

cfprFabricEthLanPcInlinePeerDn

1.3.6.1.4.1.9.9.826.1.26.32.1.41

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:inlinePeerDn managed object property

cfprFabricEthLanPcInlinePeerName

1.3.6.1.4.1.9.9.826.1.26.32.1.42

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:inlinePeerName managed object property

cfprFabricEthLanPcInlineState

1.3.6.1.4.1.9.9.826.1.26.32.1.43

CfprFabricEthLanPcInlineState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanPc:inlineState managed object property

cfprFabricEthLanPcLacpMode

1.3.6.1.4.1.9.9.826.1.26.32.1.44

CfprFabricLacpMode0 = active1 = on · Integer32

Cisco Firepower fabric:EthLanPc:lacpMode managed object property

cfprFabricEthLanPcPcMode

1.3.6.1.4.1.9.9.826.1.26.32.1.45

CfprFabricPcMode0 = active1 = on · Integer32

Cisco Firepower fabric:EthLanPc:pcMode managed object property

cfprFabricEthLanPcPcModeState

1.3.6.1.4.1.9.9.826.1.26.32.1.46

CfprFabricPcModeState0 = disabled1 = enabled · Integer32

Cisco Firepower fabric:EthLanPc:pcModeState managed object property

cfprFabricEthLanPcQosPrio

1.3.6.1.4.1.9.9.826.1.26.32.1.47

CfprFabricQosPrio0 = low1 = high · Integer32

Cisco Firepower fabric:EthLanPc:qosPrio managed object property

cfprFabricEthLanPcSpeedCap

1.3.6.1.4.1.9.9.826.1.26.32.1.48

CfprEquipmentEthPortSpeedCap · BITS

Cisco Firepower fabric:EthLanPc:speedCap managed object property

cfprFabricEthLanPcNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.32.1.49

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:nwCtrlPolicyName managed object property

cfprFabricEthLanPcOperNwCtrlPolicyName

1.3.6.1.4.1.9.9.826.1.26.32.1.50

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPc:operNwCtrlPolicyName managed object property

cfprFabricEthLanPcLastSvcStateDownReason

1.3.6.1.4.1.9.9.826.1.26.32.1.51

CfprFabricSvcStateDownReason0 = none1 = adminDown2 = bladeShutdown3 = bladeReboot4 = appOffline5 = appDisabled6 = appFailed7 = chassisReboot · Integer32

Cisco Firepower fabric:EthLanPc:lastSvcStateDownReason managed object property

cfprFabricEthLanPcServiceState

1.3.6.1.4.1.9.9.826.1.26.32.1.52

CfprFabricEthLanPcServiceState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanPc:serviceState managed object property

cfprFabricEthLanPcEpTable

1.3.6.1.4.1.9.9.826.1.26.33

Index: cfprFabricEthLanPcEpInstanceId

Cisco Firepower fabric:EthLanPcEp managed object table

cfprFabricEthLanPcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.33.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthLanPcEpDnData

1.3.6.1.4.1.9.9.826.1.26.33.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthLanPcEp:dn managed object property

cfprFabricEthLanPcEpRn

1.3.6.1.4.1.9.9.826.1.26.33.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:rn managed object property

cfprFabricEthLanPcEpAdminState

1.3.6.1.4.1.9.9.826.1.26.33.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthLanPcEp:adminState managed object property

cfprFabricEthLanPcEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.33.1.5

Gauge32

Cisco Firepower fabric:EthLanPcEp:aggrPortId managed object property

cfprFabricEthLanPcEpChassisId

1.3.6.1.4.1.9.9.826.1.26.33.1.6

Gauge32

Cisco Firepower fabric:EthLanPcEp:chassisId managed object property

cfprFabricEthLanPcEpEpDn

1.3.6.1.4.1.9.9.826.1.26.33.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:epDn managed object property

cfprFabricEthLanPcEpEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.33.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:ethLinkProfileName managed object property

cfprFabricEthLanPcEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.33.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthLanPcEp:fltAggr managed object property

cfprFabricEthLanPcEpIfRole

1.3.6.1.4.1.9.9.826.1.26.33.1.10

CfprFabricLanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthLanPcEp:ifRole managed object property

cfprFabricEthLanPcEpIfType

1.3.6.1.4.1.9.9.826.1.26.33.1.11

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthLanPcEp:ifType managed object property

cfprFabricEthLanPcEpLicGP

1.3.6.1.4.1.9.9.826.1.26.33.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthLanPcEp:licGP managed object property

cfprFabricEthLanPcEpLicState

1.3.6.1.4.1.9.9.826.1.26.33.1.13

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthLanPcEp:licState managed object property

cfprFabricEthLanPcEpLocale

1.3.6.1.4.1.9.9.826.1.26.33.1.14

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthLanPcEp:locale managed object property

cfprFabricEthLanPcEpMembership

1.3.6.1.4.1.9.9.826.1.26.33.1.15

CfprFabricMembershipStatus1 = down2 = up3 = hotStandby4 = suspended5 = individual6 = moduleRemoved7 = incompatibleSpeed8 = unknown · Integer32

Cisco Firepower fabric:EthLanPcEp:membership managed object property

cfprFabricEthLanPcEpName

1.3.6.1.4.1.9.9.826.1.26.33.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:name managed object property

cfprFabricEthLanPcEpOperEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.33.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:operEthLinkProfileName managed object property

cfprFabricEthLanPcEpOperState

1.3.6.1.4.1.9.9.826.1.26.33.1.18

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthLanPcEp:operState managed object property

cfprFabricEthLanPcEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.33.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:operStateReason managed object property

cfprFabricEthLanPcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.33.1.20

Gauge32

Cisco Firepower fabric:EthLanPcEp:peerAggrPortId managed object property

cfprFabricEthLanPcEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.33.1.21

Gauge32

Cisco Firepower fabric:EthLanPcEp:peerChassisId managed object property

cfprFabricEthLanPcEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.33.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:peerDn managed object property

cfprFabricEthLanPcEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.33.1.23

Gauge32

Cisco Firepower fabric:EthLanPcEp:peerPortId managed object property

cfprFabricEthLanPcEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.33.1.24

Gauge32

Cisco Firepower fabric:EthLanPcEp:peerSlotId managed object property

cfprFabricEthLanPcEpPortId

1.3.6.1.4.1.9.9.826.1.26.33.1.25

Gauge32

Cisco Firepower fabric:EthLanPcEp:portId managed object property

cfprFabricEthLanPcEpSlotId

1.3.6.1.4.1.9.9.826.1.26.33.1.26

Gauge32

Cisco Firepower fabric:EthLanPcEp:slotId managed object property

cfprFabricEthLanPcEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.33.1.27

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthLanPcEp:switchId managed object property

cfprFabricEthLanPcEpTransport

1.3.6.1.4.1.9.9.826.1.26.33.1.28

CfprFabricAEthLanEpTransport · BITS

Cisco Firepower fabric:EthLanPcEp:transport managed object property

cfprFabricEthLanPcEpType

1.3.6.1.4.1.9.9.826.1.26.33.1.29

CfprFabricLanEpType · BITS

Cisco Firepower fabric:EthLanPcEp:type managed object property

cfprFabricEthLanPcEpUdldOperState

1.3.6.1.4.1.9.9.826.1.26.33.1.30

CfprFabricUdldOperState0 = unknown1 = unidirectional2 = bidirectional3 = txRxLoop4 = mismatch5 = echoEmpty6 = adminDisabled · Integer32

Cisco Firepower fabric:EthLanPcEp:udldOperState managed object property

cfprFabricEthLanPcEpWarnings

1.3.6.1.4.1.9.9.826.1.26.33.1.31

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthLanPcEp:warnings managed object property

cfprFabricEthLanPcEpDescr

1.3.6.1.4.1.9.9.826.1.26.33.1.32

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLanPcEp:descr managed object property

cfprFabricEthLanPcEpSpeedCap

1.3.6.1.4.1.9.9.826.1.26.33.1.33

CfprEquipmentEthPortSpeedCap · BITS

Cisco Firepower fabric:EthLanPcEp:speedCap managed object property

cfprFabricEthLinkProfileTable

1.3.6.1.4.1.9.9.826.1.26.34

Index: cfprFabricEthLinkProfileInstanceId

Cisco Firepower fabric:EthLinkProfile managed object table

cfprFabricEthLinkProfileInstanceId

1.3.6.1.4.1.9.9.826.1.26.34.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthLinkProfileDn

1.3.6.1.4.1.9.9.826.1.26.34.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthLinkProfile:dn managed object property

cfprFabricEthLinkProfileRn

1.3.6.1.4.1.9.9.826.1.26.34.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:rn managed object property

cfprFabricEthLinkProfileCdpLinkPolicyName

1.3.6.1.4.1.9.9.826.1.26.34.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:cdpLinkPolicyName managed object property

cfprFabricEthLinkProfileDescr

1.3.6.1.4.1.9.9.826.1.26.34.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:descr managed object property

cfprFabricEthLinkProfileIntId

1.3.6.1.4.1.9.9.826.1.26.34.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:intId managed object property

cfprFabricEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.34.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:name managed object property

cfprFabricEthLinkProfileOperCdpLinkPolicyName

1.3.6.1.4.1.9.9.826.1.26.34.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:operCdpLinkPolicyName managed object property

cfprFabricEthLinkProfileOperUdldLinkPolicyName

1.3.6.1.4.1.9.9.826.1.26.34.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:operUdldLinkPolicyName managed object property

cfprFabricEthLinkProfilePolicyLevel

1.3.6.1.4.1.9.9.826.1.26.34.1.10

Gauge32

Cisco Firepower fabric:EthLinkProfile:policyLevel managed object property

cfprFabricEthLinkProfilePolicyOwner

1.3.6.1.4.1.9.9.826.1.26.34.1.11

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:EthLinkProfile:policyOwner managed object property

cfprFabricEthLinkProfileUdldLinkPolicyName

1.3.6.1.4.1.9.9.826.1.26.34.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthLinkProfile:udldLinkPolicyName managed object property

cfprFabricEthMonTable

1.3.6.1.4.1.9.9.826.1.26.35

Index: cfprFabricEthMonInstanceId

Cisco Firepower fabric:EthMon managed object table

cfprFabricEthMonInstanceId

1.3.6.1.4.1.9.9.826.1.26.35.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonDn

1.3.6.1.4.1.9.9.826.1.26.35.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMon:dn managed object property

cfprFabricEthMonRn

1.3.6.1.4.1.9.9.826.1.26.35.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMon:rn managed object property

cfprFabricEthMonAdminState

1.3.6.1.4.1.9.9.826.1.26.35.1.4

CfprFabricMonAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthMon:adminState managed object property

cfprFabricEthMonConfigFailReason

1.3.6.1.4.1.9.9.826.1.26.35.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMon:configFailReason managed object property

cfprFabricEthMonId

1.3.6.1.4.1.9.9.826.1.26.35.1.6

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthMon:id managed object property

cfprFabricEthMonIsConfigSuccess

1.3.6.1.4.1.9.9.826.1.26.35.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthMon:isConfigSuccess managed object property

cfprFabricEthMonLocale

1.3.6.1.4.1.9.9.826.1.26.35.1.8

CfprFabricExternalLocale · BITS

Cisco Firepower fabric:EthMon:locale managed object property

cfprFabricEthMonName

1.3.6.1.4.1.9.9.826.1.26.35.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMon:name managed object property

cfprFabricEthMonOperState

1.3.6.1.4.1.9.9.826.1.26.35.1.10

CfprFabricMonOperState0 = unknown1 = up2 = down3 = error · Integer32

Cisco Firepower fabric:EthMon:operState managed object property

cfprFabricEthMonOperStateReason

1.3.6.1.4.1.9.9.826.1.26.35.1.11

CfprFabricMonOperStateReason0 = active1 = noHardwareResource2 = noOperationalSrcDst3 = genericError4 = noSourcesConfigured5 = noDestinationConfigured6 = noSourceDestinationConfigured7 = sessionAdminShut8 = wrongDestinationMode9 = wrongSourceMode10 = tunnelMisconfDown11 = noFlowIdSpecified12 = unknown · Integer32

Cisco Firepower fabric:EthMon:operStateReason managed object property

cfprFabricEthMonPeerDn

1.3.6.1.4.1.9.9.826.1.26.35.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMon:peerDn managed object property

cfprFabricEthMonSession

1.3.6.1.4.1.9.9.826.1.26.35.1.13

Gauge32

Cisco Firepower fabric:EthMon:session managed object property

cfprFabricEthMonTransport

1.3.6.1.4.1.9.9.826.1.26.35.1.14

CfprFabricEthMonTransport · BITS

Cisco Firepower fabric:EthMon:transport managed object property

cfprFabricEthMonType

1.3.6.1.4.1.9.9.826.1.26.35.1.15

CfprFabricEthMonType · BITS

Cisco Firepower fabric:EthMon:type managed object property

cfprFabricEthMonDestEpTable

1.3.6.1.4.1.9.9.826.1.26.36

Index: cfprFabricEthMonDestEpInstanceId

Cisco Firepower fabric:EthMonDestEp managed object table

cfprFabricEthMonDestEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.36.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonDestEpDn

1.3.6.1.4.1.9.9.826.1.26.36.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMonDestEp:dn managed object property

cfprFabricEthMonDestEpRn

1.3.6.1.4.1.9.9.826.1.26.36.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonDestEp:rn managed object property

cfprFabricEthMonDestEpAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.36.1.4

CfprFabricEthMonDestEpAdminSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps · Integer32

Cisco Firepower fabric:EthMonDestEp:adminSpeed managed object property

cfprFabricEthMonDestEpAdminState

1.3.6.1.4.1.9.9.826.1.26.36.1.5

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthMonDestEp:adminState managed object property

cfprFabricEthMonDestEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.36.1.6

Gauge32

Cisco Firepower fabric:EthMonDestEp:aggrPortId managed object property

cfprFabricEthMonDestEpChassisId

1.3.6.1.4.1.9.9.826.1.26.36.1.7

Gauge32

Cisco Firepower fabric:EthMonDestEp:chassisId managed object property

cfprFabricEthMonDestEpEpDn

1.3.6.1.4.1.9.9.826.1.26.36.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonDestEp:epDn managed object property

cfprFabricEthMonDestEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.36.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthMonDestEp:fltAggr managed object property

cfprFabricEthMonDestEpIfRole

1.3.6.1.4.1.9.9.826.1.26.36.1.10

CfprFabricEthMonDestEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthMonDestEp:ifRole managed object property

cfprFabricEthMonDestEpIfType

1.3.6.1.4.1.9.9.826.1.26.36.1.11

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthMonDestEp:ifType managed object property

cfprFabricEthMonDestEpLicGP

1.3.6.1.4.1.9.9.826.1.26.36.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthMonDestEp:licGP managed object property

cfprFabricEthMonDestEpLicState

1.3.6.1.4.1.9.9.826.1.26.36.1.13

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthMonDestEp:licState managed object property

cfprFabricEthMonDestEpLocale

1.3.6.1.4.1.9.9.826.1.26.36.1.14

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthMonDestEp:locale managed object property

cfprFabricEthMonDestEpName

1.3.6.1.4.1.9.9.826.1.26.36.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonDestEp:name managed object property

cfprFabricEthMonDestEpOperState

1.3.6.1.4.1.9.9.826.1.26.36.1.16

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthMonDestEp:operState managed object property

cfprFabricEthMonDestEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.36.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonDestEp:operStateReason managed object property

cfprFabricEthMonDestEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.36.1.18

Gauge32

Cisco Firepower fabric:EthMonDestEp:peerAggrPortId managed object property

cfprFabricEthMonDestEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.36.1.19

Gauge32

Cisco Firepower fabric:EthMonDestEp:peerChassisId managed object property

cfprFabricEthMonDestEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.36.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonDestEp:peerDn managed object property

cfprFabricEthMonDestEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.36.1.21

Gauge32

Cisco Firepower fabric:EthMonDestEp:peerPortId managed object property

cfprFabricEthMonDestEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.36.1.22

Gauge32

Cisco Firepower fabric:EthMonDestEp:peerSlotId managed object property

cfprFabricEthMonDestEpPortId

1.3.6.1.4.1.9.9.826.1.26.36.1.23

CfprFabricEthMonDestEpPortId (1..48) · Gauge32

Cisco Firepower fabric:EthMonDestEp:portId managed object property

cfprFabricEthMonDestEpSlotId

1.3.6.1.4.1.9.9.826.1.26.36.1.24

CfprFabricEthMonDestEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:EthMonDestEp:slotId managed object property

cfprFabricEthMonDestEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.36.1.25

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthMonDestEp:switchId managed object property

cfprFabricEthMonDestEpTransport

1.3.6.1.4.1.9.9.826.1.26.36.1.26

CfprNetworkTransport · BITS

Cisco Firepower fabric:EthMonDestEp:transport managed object property

cfprFabricEthMonDestEpType

1.3.6.1.4.1.9.9.826.1.26.36.1.27

CfprFabricEthMonDestEpType · BITS

Cisco Firepower fabric:EthMonDestEp:type managed object property

cfprFabricEthMonDestEpWarnings

1.3.6.1.4.1.9.9.826.1.26.36.1.28

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthMonDestEp:warnings managed object property

cfprFabricEthMonFiltEpTable

1.3.6.1.4.1.9.9.826.1.26.37

Index: cfprFabricEthMonFiltEpInstanceId

Cisco Firepower fabric:EthMonFiltEp managed object table

cfprFabricEthMonFiltEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.37.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonFiltEpDn

1.3.6.1.4.1.9.9.826.1.26.37.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMonFiltEp:dn managed object property

cfprFabricEthMonFiltEpRn

1.3.6.1.4.1.9.9.826.1.26.37.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonFiltEp:rn managed object property

cfprFabricEthMonFiltEpName

1.3.6.1.4.1.9.9.826.1.26.37.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonFiltEp:name managed object property

cfprFabricEthMonFiltEpSession

1.3.6.1.4.1.9.9.826.1.26.37.1.5

Gauge32

Cisco Firepower fabric:EthMonFiltEp:session managed object property

cfprFabricEthMonFiltEpType

1.3.6.1.4.1.9.9.826.1.26.37.1.6

CfprFabricEthMonFiltEpType · BITS

Cisco Firepower fabric:EthMonFiltEp:type managed object property

cfprFabricEthMonFiltRefTable

1.3.6.1.4.1.9.9.826.1.26.38

Index: cfprFabricEthMonFiltRefInstanceId

Cisco Firepower fabric:EthMonFiltRef managed object table

cfprFabricEthMonFiltRefInstanceId

1.3.6.1.4.1.9.9.826.1.26.38.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonFiltRefDn

1.3.6.1.4.1.9.9.826.1.26.38.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMonFiltRef:dn managed object property

cfprFabricEthMonFiltRefRn

1.3.6.1.4.1.9.9.826.1.26.38.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonFiltRef:rn managed object property

cfprFabricEthMonFiltRefSrcFiltDn

1.3.6.1.4.1.9.9.826.1.26.38.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonFiltRef:srcFiltDn managed object property

cfprFabricEthMonFiltRefType

1.3.6.1.4.1.9.9.826.1.26.38.1.5

CfprFabricEthMonFiltRefType · BITS

Cisco Firepower fabric:EthMonFiltRef:type managed object property

cfprFabricEthMonLanTable

1.3.6.1.4.1.9.9.826.1.26.39

Index: cfprFabricEthMonLanInstanceId

Cisco Firepower fabric:EthMonLan managed object table

cfprFabricEthMonLanInstanceId

1.3.6.1.4.1.9.9.826.1.26.39.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonLanDn

1.3.6.1.4.1.9.9.826.1.26.39.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMonLan:dn managed object property

cfprFabricEthMonLanRn

1.3.6.1.4.1.9.9.826.1.26.39.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonLan:rn managed object property

cfprFabricEthMonLanId

1.3.6.1.4.1.9.9.826.1.26.39.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthMonLan:id managed object property

cfprFabricEthMonLanLocale

1.3.6.1.4.1.9.9.826.1.26.39.1.5

CfprFabricExternalLocale · BITS

Cisco Firepower fabric:EthMonLan:locale managed object property

cfprFabricEthMonLanName

1.3.6.1.4.1.9.9.826.1.26.39.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonLan:name managed object property

cfprFabricEthMonLanTransport

1.3.6.1.4.1.9.9.826.1.26.39.1.7

CfprFabricEthMonLanTransport · BITS

Cisco Firepower fabric:EthMonLan:transport managed object property

cfprFabricEthMonLanType

1.3.6.1.4.1.9.9.826.1.26.39.1.8

CfprFabricEthMonLanType · BITS

Cisco Firepower fabric:EthMonLan:type managed object property

cfprFabricEthMonSrcEpTable

1.3.6.1.4.1.9.9.826.1.26.40

Index: cfprFabricEthMonSrcEpInstanceId

Cisco Firepower fabric:EthMonSrcEp managed object table

cfprFabricEthMonSrcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.40.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonSrcEpDn

1.3.6.1.4.1.9.9.826.1.26.40.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMonSrcEp:dn managed object property

cfprFabricEthMonSrcEpRn

1.3.6.1.4.1.9.9.826.1.26.40.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonSrcEp:rn managed object property

cfprFabricEthMonSrcEpDirection

1.3.6.1.4.1.9.9.826.1.26.40.1.4

CfprFabricTrafficDirection1 = rx2 = tx3 = both · Integer32

Cisco Firepower fabric:EthMonSrcEp:direction managed object property

cfprFabricEthMonSrcEpName

1.3.6.1.4.1.9.9.826.1.26.40.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonSrcEp:name managed object property

cfprFabricEthMonSrcEpSession

1.3.6.1.4.1.9.9.826.1.26.40.1.6

Gauge32

Cisco Firepower fabric:EthMonSrcEp:session managed object property

cfprFabricEthMonSrcEpTransport

1.3.6.1.4.1.9.9.826.1.26.40.1.7

CfprNetworkTransport · BITS

Cisco Firepower fabric:EthMonSrcEp:transport managed object property

cfprFabricEthMonSrcEpType

1.3.6.1.4.1.9.9.826.1.26.40.1.8

CfprFabricEthMonSrcEpType · BITS

Cisco Firepower fabric:EthMonSrcEp:type managed object property

cfprFabricEthMonSrcRefTable

1.3.6.1.4.1.9.9.826.1.26.41

Index: cfprFabricEthMonSrcRefInstanceId

Cisco Firepower fabric:EthMonSrcRef managed object table

cfprFabricEthMonSrcRefInstanceId

1.3.6.1.4.1.9.9.826.1.26.41.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthMonSrcRefDn

1.3.6.1.4.1.9.9.826.1.26.41.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthMonSrcRef:dn managed object property

cfprFabricEthMonSrcRefRn

1.3.6.1.4.1.9.9.826.1.26.41.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonSrcRef:rn managed object property

cfprFabricEthMonSrcRefId

1.3.6.1.4.1.9.9.826.1.26.41.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthMonSrcRef:id managed object property

cfprFabricEthMonSrcRefSourceDn

1.3.6.1.4.1.9.9.826.1.26.41.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthMonSrcRef:sourceDn managed object property

cfprFabricEthMonSrcRefSourceType

1.3.6.1.4.1.9.9.826.1.26.41.1.6

CfprFabricEthSourceType1 = vnic2 = uplinkPort3 = vlan4 = serverPort5 = portChannel6 = hostPort7 = storage8 = nasPort9 = nasPortChannel10 = fcoeuplinkPort11 = fcoeuplinkPortchannel12 = vmNic20 = vhba · Integer32

Cisco Firepower fabric:EthMonSrcRef:sourceType managed object property

cfprFabricEthMonSrcRefType

1.3.6.1.4.1.9.9.826.1.26.41.1.7

CfprFabricEthMonSrcRefType · BITS

Cisco Firepower fabric:EthMonSrcRef:type managed object property

cfprFabricEthTargetEpTable

1.3.6.1.4.1.9.9.826.1.26.42

Index: cfprFabricEthTargetEpInstanceId

Cisco Firepower fabric:EthTargetEp managed object table

cfprFabricEthTargetEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.42.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthTargetEpDn

1.3.6.1.4.1.9.9.826.1.26.42.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthTargetEp:dn managed object property

cfprFabricEthTargetEpRn

1.3.6.1.4.1.9.9.826.1.26.42.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthTargetEp:rn managed object property

cfprFabricEthTargetEpAdminState

1.3.6.1.4.1.9.9.826.1.26.42.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthTargetEp:adminState managed object property

cfprFabricEthTargetEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.42.1.5

Gauge32

Cisco Firepower fabric:EthTargetEp:aggrPortId managed object property

cfprFabricEthTargetEpChassisId

1.3.6.1.4.1.9.9.826.1.26.42.1.6

Gauge32

Cisco Firepower fabric:EthTargetEp:chassisId managed object property

cfprFabricEthTargetEpEpDn

1.3.6.1.4.1.9.9.826.1.26.42.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthTargetEp:epDn managed object property

cfprFabricEthTargetEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.42.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthTargetEp:fltAggr managed object property

cfprFabricEthTargetEpIfRole

1.3.6.1.4.1.9.9.826.1.26.42.1.9

CfprNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthTargetEp:ifRole managed object property

cfprFabricEthTargetEpIfType

1.3.6.1.4.1.9.9.826.1.26.42.1.10

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthTargetEp:ifType managed object property

cfprFabricEthTargetEpLicGP

1.3.6.1.4.1.9.9.826.1.26.42.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthTargetEp:licGP managed object property

cfprFabricEthTargetEpLicState

1.3.6.1.4.1.9.9.826.1.26.42.1.12

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthTargetEp:licState managed object property

cfprFabricEthTargetEpLocale

1.3.6.1.4.1.9.9.826.1.26.42.1.13

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthTargetEp:locale managed object property

cfprFabricEthTargetEpMacAddress

1.3.6.1.4.1.9.9.826.1.26.42.1.14

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower fabric:EthTargetEp:macAddress managed object property

cfprFabricEthTargetEpName

1.3.6.1.4.1.9.9.826.1.26.42.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthTargetEp:name managed object property

cfprFabricEthTargetEpOperState

1.3.6.1.4.1.9.9.826.1.26.42.1.16

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthTargetEp:operState managed object property

cfprFabricEthTargetEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.42.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthTargetEp:operStateReason managed object property

cfprFabricEthTargetEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.42.1.18

Gauge32

Cisco Firepower fabric:EthTargetEp:peerAggrPortId managed object property

cfprFabricEthTargetEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.42.1.19

Gauge32

Cisco Firepower fabric:EthTargetEp:peerChassisId managed object property

cfprFabricEthTargetEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.42.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthTargetEp:peerDn managed object property

cfprFabricEthTargetEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.42.1.21

Gauge32

Cisco Firepower fabric:EthTargetEp:peerPortId managed object property

cfprFabricEthTargetEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.42.1.22

Gauge32

Cisco Firepower fabric:EthTargetEp:peerSlotId managed object property

cfprFabricEthTargetEpPortId

1.3.6.1.4.1.9.9.826.1.26.42.1.23

CfprFabricPIoEpPortId (1..48) · Gauge32

Cisco Firepower fabric:EthTargetEp:portId managed object property

cfprFabricEthTargetEpSlotId

1.3.6.1.4.1.9.9.826.1.26.42.1.24

CfprFabricPIoEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:EthTargetEp:slotId managed object property

cfprFabricEthTargetEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.42.1.25

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthTargetEp:switchId managed object property

cfprFabricEthTargetEpTransport

1.3.6.1.4.1.9.9.826.1.26.42.1.26

CfprFabricEthTargetEpTransport · BITS

Cisco Firepower fabric:EthTargetEp:transport managed object property

cfprFabricEthTargetEpType

1.3.6.1.4.1.9.9.826.1.26.42.1.27

CfprFabricTargetEpType · BITS

Cisco Firepower fabric:EthTargetEp:type managed object property

cfprFabricEthTargetEpWarnings

1.3.6.1.4.1.9.9.826.1.26.42.1.28

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthTargetEp:warnings managed object property

cfprFabricEthVlanPcTable

1.3.6.1.4.1.9.9.826.1.26.43

Index: cfprFabricEthVlanPcInstanceId

Cisco Firepower fabric:EthVlanPc managed object table

cfprFabricEthVlanPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.43.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthVlanPcDn

1.3.6.1.4.1.9.9.826.1.26.43.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthVlanPc:dn managed object property

cfprFabricEthVlanPcRn

1.3.6.1.4.1.9.9.826.1.26.43.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPc:rn managed object property

cfprFabricEthVlanPcAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.43.1.4

CfprPortEthAdminSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps · Integer32

Cisco Firepower fabric:EthVlanPc:adminSpeed managed object property

cfprFabricEthVlanPcAdminState

1.3.6.1.4.1.9.9.826.1.26.43.1.5

CfprFabricCIoEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthVlanPc:adminState managed object property

cfprFabricEthVlanPcDescr

1.3.6.1.4.1.9.9.826.1.26.43.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPc:descr managed object property

cfprFabricEthVlanPcEpDn

1.3.6.1.4.1.9.9.826.1.26.43.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPc:epDn managed object property

cfprFabricEthVlanPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.43.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthVlanPc:fltAggr managed object property

cfprFabricEthVlanPcIfRole

1.3.6.1.4.1.9.9.826.1.26.43.1.9

CfprFabricEstcPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthVlanPc:ifRole managed object property

cfprFabricEthVlanPcIfType

1.3.6.1.4.1.9.9.826.1.26.43.1.10

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthVlanPc:ifType managed object property

cfprFabricEthVlanPcIsNative

1.3.6.1.4.1.9.9.826.1.26.43.1.11

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthVlanPc:isNative managed object property

cfprFabricEthVlanPcLocale

1.3.6.1.4.1.9.9.826.1.26.43.1.12

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:EthVlanPc:locale managed object property

cfprFabricEthVlanPcName

1.3.6.1.4.1.9.9.826.1.26.43.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPc:name managed object property

cfprFabricEthVlanPcOperSpeed

1.3.6.1.4.1.9.9.826.1.26.43.1.14

CfprPortEthSpeed0 = indeterminate1 = n1gbps2 = n10gbps3 = n20gbps4 = n40gbps5 = n100gbps6 = n10mbps7 = n100mbps · Integer32

Cisco Firepower fabric:EthVlanPc:operSpeed managed object property

cfprFabricEthVlanPcOperState

1.3.6.1.4.1.9.9.826.1.26.43.1.15

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:EthVlanPc:operState managed object property

cfprFabricEthVlanPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.43.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPc:peerDn managed object property

cfprFabricEthVlanPcPortId

1.3.6.1.4.1.9.9.826.1.26.43.1.17

Gauge32

Cisco Firepower fabric:EthVlanPc:portId managed object property

cfprFabricEthVlanPcStateQual

1.3.6.1.4.1.9.9.826.1.26.43.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPc:stateQual managed object property

cfprFabricEthVlanPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.43.1.19

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthVlanPc:switchId managed object property

cfprFabricEthVlanPcTransport

1.3.6.1.4.1.9.9.826.1.26.43.1.20

CfprFabricEthVlanPcTransport · BITS

Cisco Firepower fabric:EthVlanPc:transport managed object property

cfprFabricEthVlanPcType

1.3.6.1.4.1.9.9.826.1.26.43.1.21

CfprFabricEstcPcType · BITS

Cisco Firepower fabric:EthVlanPc:type managed object property

cfprFabricEthVlanPcWarnings

1.3.6.1.4.1.9.9.826.1.26.43.1.22

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthVlanPc:warnings managed object property

cfprFabricEthVlanPortEpTable

1.3.6.1.4.1.9.9.826.1.26.44

Index: cfprFabricEthVlanPortEpInstanceId

Cisco Firepower fabric:EthVlanPortEp managed object table

cfprFabricEthVlanPortEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.44.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricEthVlanPortEpDn

1.3.6.1.4.1.9.9.826.1.26.44.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:EthVlanPortEp:dn managed object property

cfprFabricEthVlanPortEpRn

1.3.6.1.4.1.9.9.826.1.26.44.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPortEp:rn managed object property

cfprFabricEthVlanPortEpAdminState

1.3.6.1.4.1.9.9.826.1.26.44.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:EthVlanPortEp:adminState managed object property

cfprFabricEthVlanPortEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.44.1.5

Gauge32

Cisco Firepower fabric:EthVlanPortEp:aggrPortId managed object property

cfprFabricEthVlanPortEpChassisId

1.3.6.1.4.1.9.9.826.1.26.44.1.6

Gauge32

Cisco Firepower fabric:EthVlanPortEp:chassisId managed object property

cfprFabricEthVlanPortEpEpDn

1.3.6.1.4.1.9.9.826.1.26.44.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPortEp:epDn managed object property

cfprFabricEthVlanPortEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.44.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthVlanPortEp:fltAggr managed object property

cfprFabricEthVlanPortEpIfRole

1.3.6.1.4.1.9.9.826.1.26.44.1.9

CfprFabricLanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:EthVlanPortEp:ifRole managed object property

cfprFabricEthVlanPortEpIfType

1.3.6.1.4.1.9.9.826.1.26.44.1.10

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:EthVlanPortEp:ifType managed object property

cfprFabricEthVlanPortEpIsNative

1.3.6.1.4.1.9.9.826.1.26.44.1.11

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:EthVlanPortEp:isNative managed object property

cfprFabricEthVlanPortEpLicGP

1.3.6.1.4.1.9.9.826.1.26.44.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:EthVlanPortEp:licGP managed object property

cfprFabricEthVlanPortEpLicState

1.3.6.1.4.1.9.9.826.1.26.44.1.13

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:EthVlanPortEp:licState managed object property

cfprFabricEthVlanPortEpLocale

1.3.6.1.4.1.9.9.826.1.26.44.1.14

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:EthVlanPortEp:locale managed object property

cfprFabricEthVlanPortEpName

1.3.6.1.4.1.9.9.826.1.26.44.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPortEp:name managed object property

cfprFabricEthVlanPortEpOperState

1.3.6.1.4.1.9.9.826.1.26.44.1.16

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:EthVlanPortEp:operState managed object property

cfprFabricEthVlanPortEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.44.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPortEp:operStateReason managed object property

cfprFabricEthVlanPortEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.44.1.18

Gauge32

Cisco Firepower fabric:EthVlanPortEp:peerAggrPortId managed object property

cfprFabricEthVlanPortEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.44.1.19

Gauge32

Cisco Firepower fabric:EthVlanPortEp:peerChassisId managed object property

cfprFabricEthVlanPortEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.44.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:EthVlanPortEp:peerDn managed object property

cfprFabricEthVlanPortEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.44.1.21

Gauge32

Cisco Firepower fabric:EthVlanPortEp:peerPortId managed object property

cfprFabricEthVlanPortEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.44.1.22

Gauge32

Cisco Firepower fabric:EthVlanPortEp:peerSlotId managed object property

cfprFabricEthVlanPortEpPortId

1.3.6.1.4.1.9.9.826.1.26.44.1.23

Gauge32

Cisco Firepower fabric:EthVlanPortEp:portId managed object property

cfprFabricEthVlanPortEpSlotId

1.3.6.1.4.1.9.9.826.1.26.44.1.24

Gauge32

Cisco Firepower fabric:EthVlanPortEp:slotId managed object property

cfprFabricEthVlanPortEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.44.1.25

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:EthVlanPortEp:switchId managed object property

cfprFabricEthVlanPortEpTransport

1.3.6.1.4.1.9.9.826.1.26.44.1.26

CfprFabricAEthLanEpTransport · BITS

Cisco Firepower fabric:EthVlanPortEp:transport managed object property

cfprFabricEthVlanPortEpType

1.3.6.1.4.1.9.9.826.1.26.44.1.27

CfprFabricLanEpType · BITS

Cisco Firepower fabric:EthVlanPortEp:type managed object property

cfprFabricEthVlanPortEpWarnings

1.3.6.1.4.1.9.9.826.1.26.44.1.28

CfprFabricWarnings · BITS

Cisco Firepower fabric:EthVlanPortEp:warnings managed object property

cfprFabricFcSanTable

1.3.6.1.4.1.9.9.826.1.26.55

Index: cfprFabricFcSanInstanceId

Cisco Firepower fabric:FcSan managed object table

cfprFabricFcSanInstanceId

1.3.6.1.4.1.9.9.826.1.26.55.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcSanDn

1.3.6.1.4.1.9.9.826.1.26.55.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcSan:dn managed object property

cfprFabricFcSanRn

1.3.6.1.4.1.9.9.826.1.26.55.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSan:rn managed object property

cfprFabricFcSanId

1.3.6.1.4.1.9.9.826.1.26.55.1.4

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcSan:id managed object property

cfprFabricFcSanLocale

1.3.6.1.4.1.9.9.826.1.26.55.1.5

CfprFabricExternalLocale · BITS

Cisco Firepower fabric:FcSan:locale managed object property

cfprFabricFcSanName

1.3.6.1.4.1.9.9.826.1.26.55.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSan:name managed object property

cfprFabricFcSanTransport

1.3.6.1.4.1.9.9.826.1.26.55.1.7

CfprFabricFcSanTransport · BITS

Cisco Firepower fabric:FcSan:transport managed object property

cfprFabricFcSanType

1.3.6.1.4.1.9.9.826.1.26.55.1.8

CfprFabricSanType · BITS

Cisco Firepower fabric:FcSan:type managed object property

cfprFabricFcSanUplinkTrunking

1.3.6.1.4.1.9.9.826.1.26.55.1.9

CfprFabricFcSanUplinkTrunking0 = disabled1 = enabled · Integer32

Cisco Firepower fabric:FcSan:uplinkTrunking managed object property

cfprFabricFcSanEpTable

1.3.6.1.4.1.9.9.826.1.26.56

Index: cfprFabricFcSanEpInstanceId

Cisco Firepower fabric:FcSanEp managed object table

cfprFabricFcSanEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.56.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcSanEpDn

1.3.6.1.4.1.9.9.826.1.26.56.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcSanEp:dn managed object property

cfprFabricFcSanEpRn

1.3.6.1.4.1.9.9.826.1.26.56.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanEp:rn managed object property

cfprFabricFcSanEpAdminState

1.3.6.1.4.1.9.9.826.1.26.56.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcSanEp:adminState managed object property

cfprFabricFcSanEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.56.1.5

Gauge32

Cisco Firepower fabric:FcSanEp:aggrPortId managed object property

cfprFabricFcSanEpChassisId

1.3.6.1.4.1.9.9.826.1.26.56.1.6

Gauge32

Cisco Firepower fabric:FcSanEp:chassisId managed object property

cfprFabricFcSanEpEpDn

1.3.6.1.4.1.9.9.826.1.26.56.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanEp:epDn managed object property

cfprFabricFcSanEpFillPattern

1.3.6.1.4.1.9.9.826.1.26.56.1.8

CfprFabricFillPattern0 = idle1 = arbff · Integer32

Cisco Firepower fabric:FcSanEp:fillPattern managed object property

cfprFabricFcSanEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.56.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcSanEp:fltAggr managed object property

cfprFabricFcSanEpIfRole

1.3.6.1.4.1.9.9.826.1.26.56.1.10

CfprFabricSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcSanEp:ifRole managed object property

cfprFabricFcSanEpIfType

1.3.6.1.4.1.9.9.826.1.26.56.1.11

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcSanEp:ifType managed object property

cfprFabricFcSanEpLicGP

1.3.6.1.4.1.9.9.826.1.26.56.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcSanEp:licGP managed object property

cfprFabricFcSanEpLicState

1.3.6.1.4.1.9.9.826.1.26.56.1.13

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:FcSanEp:licState managed object property

cfprFabricFcSanEpLocale

1.3.6.1.4.1.9.9.826.1.26.56.1.14

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:FcSanEp:locale managed object property

cfprFabricFcSanEpName

1.3.6.1.4.1.9.9.826.1.26.56.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanEp:name managed object property

cfprFabricFcSanEpOperState

1.3.6.1.4.1.9.9.826.1.26.56.1.16

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:FcSanEp:operState managed object property

cfprFabricFcSanEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.56.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanEp:operStateReason managed object property

cfprFabricFcSanEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.56.1.18

Gauge32

Cisco Firepower fabric:FcSanEp:peerAggrPortId managed object property

cfprFabricFcSanEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.56.1.19

Gauge32

Cisco Firepower fabric:FcSanEp:peerChassisId managed object property

cfprFabricFcSanEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.56.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanEp:peerDn managed object property

cfprFabricFcSanEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.56.1.21

Gauge32

Cisco Firepower fabric:FcSanEp:peerPortId managed object property

cfprFabricFcSanEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.56.1.22

Gauge32

Cisco Firepower fabric:FcSanEp:peerSlotId managed object property

cfprFabricFcSanEpPortId

1.3.6.1.4.1.9.9.826.1.26.56.1.23

CfprFabricFcSanEpPortId (1..48) · Gauge32

Cisco Firepower fabric:FcSanEp:portId managed object property

cfprFabricFcSanEpSlotId

1.3.6.1.4.1.9.9.826.1.26.56.1.24

CfprFabricFcSanEpSlotId (1..5) · Gauge32

Cisco Firepower fabric:FcSanEp:slotId managed object property

cfprFabricFcSanEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.56.1.25

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcSanEp:switchId managed object property

cfprFabricFcSanEpTransport

1.3.6.1.4.1.9.9.826.1.26.56.1.26

CfprFabricAFcSanEpTransport · BITS

Cisco Firepower fabric:FcSanEp:transport managed object property

cfprFabricFcSanEpType

1.3.6.1.4.1.9.9.826.1.26.56.1.27

CfprFabricSanEpType · BITS

Cisco Firepower fabric:FcSanEp:type managed object property

cfprFabricFcSanEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.56.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanEp:usrLbl managed object property

cfprFabricFcSanEpWarnings

1.3.6.1.4.1.9.9.826.1.26.56.1.29

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcSanEp:warnings managed object property

cfprFabricFcSanPcTable

1.3.6.1.4.1.9.9.826.1.26.57

Index: cfprFabricFcSanPcInstanceId

Cisco Firepower fabric:FcSanPc managed object table

cfprFabricFcSanPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.57.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcSanPcDn

1.3.6.1.4.1.9.9.826.1.26.57.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcSanPc:dn managed object property

cfprFabricFcSanPcRn

1.3.6.1.4.1.9.9.826.1.26.57.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPc:rn managed object property

cfprFabricFcSanPcAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.57.1.4

CfprPortSpeed0 = indeterminate1 = n1gbps2 = n2gbps3 = n4gbps4 = n8gbps5 = auto · Integer32

Cisco Firepower fabric:FcSanPc:adminSpeed managed object property

cfprFabricFcSanPcAdminState

1.3.6.1.4.1.9.9.826.1.26.57.1.5

CfprFabricCIoEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcSanPc:adminState managed object property

cfprFabricFcSanPcConfigState

1.3.6.1.4.1.9.9.826.1.26.57.1.6

CfprFabricConfigState1 = applied2 = inconsistent · Integer32

Cisco Firepower fabric:FcSanPc:configState managed object property

cfprFabricFcSanPcConfigStatus

1.3.6.1.4.1.9.9.826.1.26.57.1.7

CfprFabricPcConfigStatus1 = applied2 = incompatibleSpeed · Integer32

Cisco Firepower fabric:FcSanPc:configStatus managed object property

cfprFabricFcSanPcDescr

1.3.6.1.4.1.9.9.826.1.26.57.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPc:descr managed object property

cfprFabricFcSanPcEpDn

1.3.6.1.4.1.9.9.826.1.26.57.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPc:epDn managed object property

cfprFabricFcSanPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.57.1.10

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcSanPc:fltAggr managed object property

cfprFabricFcSanPcIfRole

1.3.6.1.4.1.9.9.826.1.26.57.1.11

CfprFabricSanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcSanPc:ifRole managed object property

cfprFabricFcSanPcIfType

1.3.6.1.4.1.9.9.826.1.26.57.1.12

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcSanPc:ifType managed object property

cfprFabricFcSanPcLocale

1.3.6.1.4.1.9.9.826.1.26.57.1.13

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:FcSanPc:locale managed object property

cfprFabricFcSanPcName

1.3.6.1.4.1.9.9.826.1.26.57.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPc:name managed object property

cfprFabricFcSanPcOperSpeed

1.3.6.1.4.1.9.9.826.1.26.57.1.15

Gauge32

Cisco Firepower fabric:FcSanPc:operSpeed managed object property

cfprFabricFcSanPcOperState

1.3.6.1.4.1.9.9.826.1.26.57.1.16

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:FcSanPc:operState managed object property

cfprFabricFcSanPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.57.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPc:peerDn managed object property

cfprFabricFcSanPcPortId

1.3.6.1.4.1.9.9.826.1.26.57.1.18

Gauge32

Cisco Firepower fabric:FcSanPc:portId managed object property

cfprFabricFcSanPcStateQual

1.3.6.1.4.1.9.9.826.1.26.57.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPc:stateQual managed object property

cfprFabricFcSanPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.57.1.20

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcSanPc:switchId managed object property

cfprFabricFcSanPcTransport

1.3.6.1.4.1.9.9.826.1.26.57.1.21

CfprFabricFcSanPcTransport · BITS

Cisco Firepower fabric:FcSanPc:transport managed object property

cfprFabricFcSanPcType

1.3.6.1.4.1.9.9.826.1.26.57.1.22

CfprFabricSanPcType · BITS

Cisco Firepower fabric:FcSanPc:type managed object property

cfprFabricFcSanPcWarnings

1.3.6.1.4.1.9.9.826.1.26.57.1.23

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcSanPc:warnings managed object property

cfprFabricFcSanPcEpTable

1.3.6.1.4.1.9.9.826.1.26.58

Index: cfprFabricFcSanPcEpInstanceId

Cisco Firepower fabric:FcSanPcEp managed object table

cfprFabricFcSanPcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.58.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcSanPcEpDnData

1.3.6.1.4.1.9.9.826.1.26.58.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcSanPcEp:dn managed object property

cfprFabricFcSanPcEpRn

1.3.6.1.4.1.9.9.826.1.26.58.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPcEp:rn managed object property

cfprFabricFcSanPcEpAdminSpeed

1.3.6.1.4.1.9.9.826.1.26.58.1.4

CfprPortSpeed0 = indeterminate1 = n1gbps2 = n2gbps3 = n4gbps4 = n8gbps5 = auto · Integer32

Cisco Firepower fabric:FcSanPcEp:adminSpeed managed object property

cfprFabricFcSanPcEpAdminState

1.3.6.1.4.1.9.9.826.1.26.58.1.5

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcSanPcEp:adminState managed object property

cfprFabricFcSanPcEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.58.1.6

Gauge32

Cisco Firepower fabric:FcSanPcEp:aggrPortId managed object property

cfprFabricFcSanPcEpChassisId

1.3.6.1.4.1.9.9.826.1.26.58.1.7

Gauge32

Cisco Firepower fabric:FcSanPcEp:chassisId managed object property

cfprFabricFcSanPcEpEpDn

1.3.6.1.4.1.9.9.826.1.26.58.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPcEp:epDn managed object property

cfprFabricFcSanPcEpFillPattern

1.3.6.1.4.1.9.9.826.1.26.58.1.9

CfprFabricFillPattern0 = idle1 = arbff · Integer32

Cisco Firepower fabric:FcSanPcEp:fillPattern managed object property

cfprFabricFcSanPcEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.58.1.10

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcSanPcEp:fltAggr managed object property

cfprFabricFcSanPcEpIfRole

1.3.6.1.4.1.9.9.826.1.26.58.1.11

CfprFabricSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcSanPcEp:ifRole managed object property

cfprFabricFcSanPcEpIfType

1.3.6.1.4.1.9.9.826.1.26.58.1.12

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcSanPcEp:ifType managed object property

cfprFabricFcSanPcEpLicGP

1.3.6.1.4.1.9.9.826.1.26.58.1.13

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcSanPcEp:licGP managed object property

cfprFabricFcSanPcEpLicState

1.3.6.1.4.1.9.9.826.1.26.58.1.14

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:FcSanPcEp:licState managed object property

cfprFabricFcSanPcEpLocale

1.3.6.1.4.1.9.9.826.1.26.58.1.15

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:FcSanPcEp:locale managed object property

cfprFabricFcSanPcEpMembership

1.3.6.1.4.1.9.9.826.1.26.58.1.16

CfprFabricMembershipStatus1 = down2 = up3 = hotStandby4 = suspended5 = individual6 = moduleRemoved7 = incompatibleSpeed8 = unknown · Integer32

Cisco Firepower fabric:FcSanPcEp:membership managed object property

cfprFabricFcSanPcEpName

1.3.6.1.4.1.9.9.826.1.26.58.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPcEp:name managed object property

cfprFabricFcSanPcEpOperState

1.3.6.1.4.1.9.9.826.1.26.58.1.18

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:FcSanPcEp:operState managed object property

cfprFabricFcSanPcEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.58.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPcEp:operStateReason managed object property

cfprFabricFcSanPcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.58.1.20

Gauge32

Cisco Firepower fabric:FcSanPcEp:peerAggrPortId managed object property

cfprFabricFcSanPcEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.58.1.21

Gauge32

Cisco Firepower fabric:FcSanPcEp:peerChassisId managed object property

cfprFabricFcSanPcEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.58.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcSanPcEp:peerDn managed object property

cfprFabricFcSanPcEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.58.1.23

Gauge32

Cisco Firepower fabric:FcSanPcEp:peerPortId managed object property

cfprFabricFcSanPcEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.58.1.24

Gauge32

Cisco Firepower fabric:FcSanPcEp:peerSlotId managed object property

cfprFabricFcSanPcEpPortId

1.3.6.1.4.1.9.9.826.1.26.58.1.25

CfprFabricFcSanPcEpPortId (1..48) · Gauge32

Cisco Firepower fabric:FcSanPcEp:portId managed object property

cfprFabricFcSanPcEpSlotId

1.3.6.1.4.1.9.9.826.1.26.58.1.26

CfprFabricFcSanPcEpSlotId (1..5) · Gauge32

Cisco Firepower fabric:FcSanPcEp:slotId managed object property

cfprFabricFcSanPcEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.58.1.27

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcSanPcEp:switchId managed object property

cfprFabricFcSanPcEpTransport

1.3.6.1.4.1.9.9.826.1.26.58.1.28

CfprFabricAFcSanEpTransport · BITS

Cisco Firepower fabric:FcSanPcEp:transport managed object property

cfprFabricFcSanPcEpType

1.3.6.1.4.1.9.9.826.1.26.58.1.29

CfprFabricSanEpType · BITS

Cisco Firepower fabric:FcSanPcEp:type managed object property

cfprFabricFcSanPcEpWarnings

1.3.6.1.4.1.9.9.826.1.26.58.1.30

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcSanPcEp:warnings managed object property

cfprFabricFcVsanPcTable

1.3.6.1.4.1.9.9.826.1.26.59

Index: cfprFabricFcVsanPcInstanceId

Cisco Firepower fabric:FcVsanPc managed object table

cfprFabricFcVsanPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.59.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcVsanPcDn

1.3.6.1.4.1.9.9.826.1.26.59.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcVsanPc:dn managed object property

cfprFabricFcVsanPcRn

1.3.6.1.4.1.9.9.826.1.26.59.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPc:rn managed object property

cfprFabricFcVsanPcAdminState

1.3.6.1.4.1.9.9.826.1.26.59.1.4

CfprFabricCIoEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcVsanPc:adminState managed object property

cfprFabricFcVsanPcDescr

1.3.6.1.4.1.9.9.826.1.26.59.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPc:descr managed object property

cfprFabricFcVsanPcEpDn

1.3.6.1.4.1.9.9.826.1.26.59.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPc:epDn managed object property

cfprFabricFcVsanPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.59.1.7

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcVsanPc:fltAggr managed object property

cfprFabricFcVsanPcIfRole

1.3.6.1.4.1.9.9.826.1.26.59.1.8

CfprFabricSanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcVsanPc:ifRole managed object property

cfprFabricFcVsanPcIfType

1.3.6.1.4.1.9.9.826.1.26.59.1.9

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcVsanPc:ifType managed object property

cfprFabricFcVsanPcLocale

1.3.6.1.4.1.9.9.826.1.26.59.1.10

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:FcVsanPc:locale managed object property

cfprFabricFcVsanPcName

1.3.6.1.4.1.9.9.826.1.26.59.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPc:name managed object property

cfprFabricFcVsanPcOperState

1.3.6.1.4.1.9.9.826.1.26.59.1.12

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:FcVsanPc:operState managed object property

cfprFabricFcVsanPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.59.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPc:peerDn managed object property

cfprFabricFcVsanPcPortId

1.3.6.1.4.1.9.9.826.1.26.59.1.14

Gauge32

Cisco Firepower fabric:FcVsanPc:portId managed object property

cfprFabricFcVsanPcStateQual

1.3.6.1.4.1.9.9.826.1.26.59.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPc:stateQual managed object property

cfprFabricFcVsanPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.59.1.16

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcVsanPc:switchId managed object property

cfprFabricFcVsanPcTransport

1.3.6.1.4.1.9.9.826.1.26.59.1.17

CfprFabricFcVsanPcTransport · BITS

Cisco Firepower fabric:FcVsanPc:transport managed object property

cfprFabricFcVsanPcType

1.3.6.1.4.1.9.9.826.1.26.59.1.18

CfprFabricSanPcType · BITS

Cisco Firepower fabric:FcVsanPc:type managed object property

cfprFabricFcVsanPcWarnings

1.3.6.1.4.1.9.9.826.1.26.59.1.19

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcVsanPc:warnings managed object property

cfprFabricFcVsanPortEpTable

1.3.6.1.4.1.9.9.826.1.26.60

Index: cfprFabricFcVsanPortEpInstanceId

Cisco Firepower fabric:FcVsanPortEp managed object table

cfprFabricFcVsanPortEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.60.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcVsanPortEpDn

1.3.6.1.4.1.9.9.826.1.26.60.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcVsanPortEp:dn managed object property

cfprFabricFcVsanPortEpRn

1.3.6.1.4.1.9.9.826.1.26.60.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPortEp:rn managed object property

cfprFabricFcVsanPortEpAdminState

1.3.6.1.4.1.9.9.826.1.26.60.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcVsanPortEp:adminState managed object property

cfprFabricFcVsanPortEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.60.1.5

Gauge32

Cisco Firepower fabric:FcVsanPortEp:aggrPortId managed object property

cfprFabricFcVsanPortEpChassisId

1.3.6.1.4.1.9.9.826.1.26.60.1.6

Gauge32

Cisco Firepower fabric:FcVsanPortEp:chassisId managed object property

cfprFabricFcVsanPortEpEpDn

1.3.6.1.4.1.9.9.826.1.26.60.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPortEp:epDn managed object property

cfprFabricFcVsanPortEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.60.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcVsanPortEp:fltAggr managed object property

cfprFabricFcVsanPortEpIfRole

1.3.6.1.4.1.9.9.826.1.26.60.1.9

CfprFabricSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcVsanPortEp:ifRole managed object property

cfprFabricFcVsanPortEpIfType

1.3.6.1.4.1.9.9.826.1.26.60.1.10

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcVsanPortEp:ifType managed object property

cfprFabricFcVsanPortEpLicGP

1.3.6.1.4.1.9.9.826.1.26.60.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcVsanPortEp:licGP managed object property

cfprFabricFcVsanPortEpLicState

1.3.6.1.4.1.9.9.826.1.26.60.1.12

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:FcVsanPortEp:licState managed object property

cfprFabricFcVsanPortEpLocale

1.3.6.1.4.1.9.9.826.1.26.60.1.13

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:FcVsanPortEp:locale managed object property

cfprFabricFcVsanPortEpName

1.3.6.1.4.1.9.9.826.1.26.60.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPortEp:name managed object property

cfprFabricFcVsanPortEpOperState

1.3.6.1.4.1.9.9.826.1.26.60.1.15

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:FcVsanPortEp:operState managed object property

cfprFabricFcVsanPortEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.60.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPortEp:operStateReason managed object property

cfprFabricFcVsanPortEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.60.1.17

Gauge32

Cisco Firepower fabric:FcVsanPortEp:peerAggrPortId managed object property

cfprFabricFcVsanPortEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.60.1.18

Gauge32

Cisco Firepower fabric:FcVsanPortEp:peerChassisId managed object property

cfprFabricFcVsanPortEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.60.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcVsanPortEp:peerDn managed object property

cfprFabricFcVsanPortEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.60.1.20

Gauge32

Cisco Firepower fabric:FcVsanPortEp:peerPortId managed object property

cfprFabricFcVsanPortEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.60.1.21

Gauge32

Cisco Firepower fabric:FcVsanPortEp:peerSlotId managed object property

cfprFabricFcVsanPortEpPortId

1.3.6.1.4.1.9.9.826.1.26.60.1.22

CfprFabricFcVsanPortEpPortId (1..256) · Gauge32

Cisco Firepower fabric:FcVsanPortEp:portId managed object property

cfprFabricFcVsanPortEpSlotId

1.3.6.1.4.1.9.9.826.1.26.60.1.23

CfprFabricFcVsanPortEpSlotId (1..5) · Gauge32

Cisco Firepower fabric:FcVsanPortEp:slotId managed object property

cfprFabricFcVsanPortEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.60.1.24

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcVsanPortEp:switchId managed object property

cfprFabricFcVsanPortEpTransport

1.3.6.1.4.1.9.9.826.1.26.60.1.25

CfprFabricAFcSanEpTransport · BITS

Cisco Firepower fabric:FcVsanPortEp:transport managed object property

cfprFabricFcVsanPortEpType

1.3.6.1.4.1.9.9.826.1.26.60.1.26

CfprFabricSanEpType · BITS

Cisco Firepower fabric:FcVsanPortEp:type managed object property

cfprFabricFcVsanPortEpWarnings

1.3.6.1.4.1.9.9.826.1.26.60.1.27

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcVsanPortEp:warnings managed object property

cfprFabricFcoeSanEpTable

1.3.6.1.4.1.9.9.826.1.26.62

Index: cfprFabricFcoeSanEpInstanceId

Cisco Firepower fabric:FcoeSanEp managed object table

cfprFabricFcoeSanEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.62.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcoeSanEpDn

1.3.6.1.4.1.9.9.826.1.26.62.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcoeSanEp:dn managed object property

cfprFabricFcoeSanEpRn

1.3.6.1.4.1.9.9.826.1.26.62.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:rn managed object property

cfprFabricFcoeSanEpAdminState

1.3.6.1.4.1.9.9.826.1.26.62.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcoeSanEp:adminState managed object property

cfprFabricFcoeSanEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.62.1.5

Gauge32

Cisco Firepower fabric:FcoeSanEp:aggrPortId managed object property

cfprFabricFcoeSanEpChassisId

1.3.6.1.4.1.9.9.826.1.26.62.1.6

Gauge32

Cisco Firepower fabric:FcoeSanEp:chassisId managed object property

cfprFabricFcoeSanEpConfigState

1.3.6.1.4.1.9.9.826.1.26.62.1.7

CfprFabricConfigState1 = applied2 = inconsistent · Integer32

Cisco Firepower fabric:FcoeSanEp:configState managed object property

cfprFabricFcoeSanEpEpDn

1.3.6.1.4.1.9.9.826.1.26.62.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:epDn managed object property

cfprFabricFcoeSanEpEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.62.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:ethLinkProfileName managed object property

cfprFabricFcoeSanEpFcoeState

1.3.6.1.4.1.9.9.826.1.26.62.1.10

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:FcoeSanEp:fcoeState managed object property

cfprFabricFcoeSanEpFcoeStateReason

1.3.6.1.4.1.9.9.826.1.26.62.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:fcoeStateReason managed object property

cfprFabricFcoeSanEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.62.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeSanEp:fltAggr managed object property

cfprFabricFcoeSanEpIfRole

1.3.6.1.4.1.9.9.826.1.26.62.1.13

CfprFabricSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcoeSanEp:ifRole managed object property

cfprFabricFcoeSanEpIfType

1.3.6.1.4.1.9.9.826.1.26.62.1.14

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcoeSanEp:ifType managed object property

cfprFabricFcoeSanEpLicGP

1.3.6.1.4.1.9.9.826.1.26.62.1.15

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeSanEp:licGP managed object property

cfprFabricFcoeSanEpLicState

1.3.6.1.4.1.9.9.826.1.26.62.1.16

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:FcoeSanEp:licState managed object property

cfprFabricFcoeSanEpLocale

1.3.6.1.4.1.9.9.826.1.26.62.1.17

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:FcoeSanEp:locale managed object property

cfprFabricFcoeSanEpName

1.3.6.1.4.1.9.9.826.1.26.62.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:name managed object property

cfprFabricFcoeSanEpOperEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.62.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:operEthLinkProfileName managed object property

cfprFabricFcoeSanEpOperState

1.3.6.1.4.1.9.9.826.1.26.62.1.20

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:FcoeSanEp:operState managed object property

cfprFabricFcoeSanEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.62.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:operStateReason managed object property

cfprFabricFcoeSanEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.62.1.22

Gauge32

Cisco Firepower fabric:FcoeSanEp:peerAggrPortId managed object property

cfprFabricFcoeSanEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.62.1.23

Gauge32

Cisco Firepower fabric:FcoeSanEp:peerChassisId managed object property

cfprFabricFcoeSanEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.62.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:peerDn managed object property

cfprFabricFcoeSanEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.62.1.25

Gauge32

Cisco Firepower fabric:FcoeSanEp:peerPortId managed object property

cfprFabricFcoeSanEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.62.1.26

Gauge32

Cisco Firepower fabric:FcoeSanEp:peerSlotId managed object property

cfprFabricFcoeSanEpPortId

1.3.6.1.4.1.9.9.826.1.26.62.1.27

CfprFabricFcoeSanEpPortId (1..48) · Gauge32

Cisco Firepower fabric:FcoeSanEp:portId managed object property

cfprFabricFcoeSanEpSlotId

1.3.6.1.4.1.9.9.826.1.26.62.1.28

CfprFabricFcoeSanEpSlotId (1..5) · Gauge32

Cisco Firepower fabric:FcoeSanEp:slotId managed object property

cfprFabricFcoeSanEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.62.1.29

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcoeSanEp:switchId managed object property

cfprFabricFcoeSanEpTransport

1.3.6.1.4.1.9.9.826.1.26.62.1.30

CfprFabricAFcoeSanEpTransport · BITS

Cisco Firepower fabric:FcoeSanEp:transport managed object property

cfprFabricFcoeSanEpType

1.3.6.1.4.1.9.9.826.1.26.62.1.31

CfprFabricSanEpType · BITS

Cisco Firepower fabric:FcoeSanEp:type managed object property

cfprFabricFcoeSanEpUdldOperState

1.3.6.1.4.1.9.9.826.1.26.62.1.32

CfprFabricUdldOperState0 = unknown1 = unidirectional2 = bidirectional3 = txRxLoop4 = mismatch5 = echoEmpty6 = adminDisabled · Integer32

Cisco Firepower fabric:FcoeSanEp:udldOperState managed object property

cfprFabricFcoeSanEpUsrLbl

1.3.6.1.4.1.9.9.826.1.26.62.1.33

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanEp:usrLbl managed object property

cfprFabricFcoeSanEpWarnings

1.3.6.1.4.1.9.9.826.1.26.62.1.34

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcoeSanEp:warnings managed object property

cfprFabricFcoeSanPcTable

1.3.6.1.4.1.9.9.826.1.26.63

Index: cfprFabricFcoeSanPcInstanceId

Cisco Firepower fabric:FcoeSanPc managed object table

cfprFabricFcoeSanPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.63.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcoeSanPcDn

1.3.6.1.4.1.9.9.826.1.26.63.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcoeSanPc:dn managed object property

cfprFabricFcoeSanPcRn

1.3.6.1.4.1.9.9.826.1.26.63.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:rn managed object property

cfprFabricFcoeSanPcAdminState

1.3.6.1.4.1.9.9.826.1.26.63.1.4

CfprFabricCIoEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcoeSanPc:adminState managed object property

cfprFabricFcoeSanPcConfigState

1.3.6.1.4.1.9.9.826.1.26.63.1.5

CfprFabricConfigState1 = applied2 = inconsistent · Integer32

Cisco Firepower fabric:FcoeSanPc:configState managed object property

cfprFabricFcoeSanPcDescr

1.3.6.1.4.1.9.9.826.1.26.63.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:descr managed object property

cfprFabricFcoeSanPcEpDn

1.3.6.1.4.1.9.9.826.1.26.63.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:epDn managed object property

cfprFabricFcoeSanPcFcoeState

1.3.6.1.4.1.9.9.826.1.26.63.1.8

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:FcoeSanPc:fcoeState managed object property

cfprFabricFcoeSanPcFcoeStateReason

1.3.6.1.4.1.9.9.826.1.26.63.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:fcoeStateReason managed object property

cfprFabricFcoeSanPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.63.1.10

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeSanPc:fltAggr managed object property

cfprFabricFcoeSanPcIfRole

1.3.6.1.4.1.9.9.826.1.26.63.1.11

CfprFabricSanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcoeSanPc:ifRole managed object property

cfprFabricFcoeSanPcIfType

1.3.6.1.4.1.9.9.826.1.26.63.1.12

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcoeSanPc:ifType managed object property

cfprFabricFcoeSanPcLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.63.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:lacpPolicyName managed object property

cfprFabricFcoeSanPcLocale

1.3.6.1.4.1.9.9.826.1.26.63.1.14

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:FcoeSanPc:locale managed object property

cfprFabricFcoeSanPcName

1.3.6.1.4.1.9.9.826.1.26.63.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:name managed object property

cfprFabricFcoeSanPcOperLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.63.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:operLacpPolicyName managed object property

cfprFabricFcoeSanPcOperState

1.3.6.1.4.1.9.9.826.1.26.63.1.17

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:FcoeSanPc:operState managed object property

cfprFabricFcoeSanPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.63.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:peerDn managed object property

cfprFabricFcoeSanPcPortId

1.3.6.1.4.1.9.9.826.1.26.63.1.19

Gauge32

Cisco Firepower fabric:FcoeSanPc:portId managed object property

cfprFabricFcoeSanPcStateQual

1.3.6.1.4.1.9.9.826.1.26.63.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPc:stateQual managed object property

cfprFabricFcoeSanPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.63.1.21

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcoeSanPc:switchId managed object property

cfprFabricFcoeSanPcTransport

1.3.6.1.4.1.9.9.826.1.26.63.1.22

CfprFabricFcoeSanPcTransport · BITS

Cisco Firepower fabric:FcoeSanPc:transport managed object property

cfprFabricFcoeSanPcType

1.3.6.1.4.1.9.9.826.1.26.63.1.23

CfprFabricSanPcType · BITS

Cisco Firepower fabric:FcoeSanPc:type managed object property

cfprFabricFcoeSanPcWarnings

1.3.6.1.4.1.9.9.826.1.26.63.1.24

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcoeSanPc:warnings managed object property

cfprFabricFcoeSanPcEpTable

1.3.6.1.4.1.9.9.826.1.26.64

Index: cfprFabricFcoeSanPcEpInstanceId

Cisco Firepower fabric:FcoeSanPcEp managed object table

cfprFabricFcoeSanPcEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.64.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcoeSanPcEpDnData

1.3.6.1.4.1.9.9.826.1.26.64.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcoeSanPcEp:dn managed object property

cfprFabricFcoeSanPcEpRn

1.3.6.1.4.1.9.9.826.1.26.64.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:rn managed object property

cfprFabricFcoeSanPcEpAdminState

1.3.6.1.4.1.9.9.826.1.26.64.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcoeSanPcEp:adminState managed object property

cfprFabricFcoeSanPcEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.64.1.5

Gauge32

Cisco Firepower fabric:FcoeSanPcEp:aggrPortId managed object property

cfprFabricFcoeSanPcEpChassisId

1.3.6.1.4.1.9.9.826.1.26.64.1.6

Gauge32

Cisco Firepower fabric:FcoeSanPcEp:chassisId managed object property

cfprFabricFcoeSanPcEpEpDn

1.3.6.1.4.1.9.9.826.1.26.64.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:epDn managed object property

cfprFabricFcoeSanPcEpEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.64.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:ethLinkProfileName managed object property

cfprFabricFcoeSanPcEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.64.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeSanPcEp:fltAggr managed object property

cfprFabricFcoeSanPcEpIfRole

1.3.6.1.4.1.9.9.826.1.26.64.1.10

CfprFabricSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcoeSanPcEp:ifRole managed object property

cfprFabricFcoeSanPcEpIfType

1.3.6.1.4.1.9.9.826.1.26.64.1.11

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcoeSanPcEp:ifType managed object property

cfprFabricFcoeSanPcEpLicGP

1.3.6.1.4.1.9.9.826.1.26.64.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeSanPcEp:licGP managed object property

cfprFabricFcoeSanPcEpLicState

1.3.6.1.4.1.9.9.826.1.26.64.1.13

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:FcoeSanPcEp:licState managed object property

cfprFabricFcoeSanPcEpLocale

1.3.6.1.4.1.9.9.826.1.26.64.1.14

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:FcoeSanPcEp:locale managed object property

cfprFabricFcoeSanPcEpMembership

1.3.6.1.4.1.9.9.826.1.26.64.1.15

CfprFabricMembershipStatus1 = down2 = up3 = hotStandby4 = suspended5 = individual6 = moduleRemoved7 = incompatibleSpeed8 = unknown · Integer32

Cisco Firepower fabric:FcoeSanPcEp:membership managed object property

cfprFabricFcoeSanPcEpName

1.3.6.1.4.1.9.9.826.1.26.64.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:name managed object property

cfprFabricFcoeSanPcEpOperEthLinkProfileName

1.3.6.1.4.1.9.9.826.1.26.64.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:operEthLinkProfileName managed object property

cfprFabricFcoeSanPcEpOperState

1.3.6.1.4.1.9.9.826.1.26.64.1.18

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:FcoeSanPcEp:operState managed object property

cfprFabricFcoeSanPcEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.64.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:operStateReason managed object property

cfprFabricFcoeSanPcEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.64.1.20

Gauge32

Cisco Firepower fabric:FcoeSanPcEp:peerAggrPortId managed object property

cfprFabricFcoeSanPcEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.64.1.21

Gauge32

Cisco Firepower fabric:FcoeSanPcEp:peerChassisId managed object property

cfprFabricFcoeSanPcEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.64.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeSanPcEp:peerDn managed object property

cfprFabricFcoeSanPcEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.64.1.23

Gauge32

Cisco Firepower fabric:FcoeSanPcEp:peerPortId managed object property

cfprFabricFcoeSanPcEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.64.1.24

Gauge32

Cisco Firepower fabric:FcoeSanPcEp:peerSlotId managed object property

cfprFabricFcoeSanPcEpPortId

1.3.6.1.4.1.9.9.826.1.26.64.1.25

CfprFabricFcoeSanPcEpPortId (1..48) · Gauge32

Cisco Firepower fabric:FcoeSanPcEp:portId managed object property

cfprFabricFcoeSanPcEpSlotId

1.3.6.1.4.1.9.9.826.1.26.64.1.26

CfprFabricFcoeSanPcEpSlotId (1..5) · Gauge32

Cisco Firepower fabric:FcoeSanPcEp:slotId managed object property

cfprFabricFcoeSanPcEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.64.1.27

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcoeSanPcEp:switchId managed object property

cfprFabricFcoeSanPcEpTransport

1.3.6.1.4.1.9.9.826.1.26.64.1.28

CfprFabricAFcoeSanEpTransport · BITS

Cisco Firepower fabric:FcoeSanPcEp:transport managed object property

cfprFabricFcoeSanPcEpType

1.3.6.1.4.1.9.9.826.1.26.64.1.29

CfprFabricSanEpType · BITS

Cisco Firepower fabric:FcoeSanPcEp:type managed object property

cfprFabricFcoeSanPcEpUdldOperState

1.3.6.1.4.1.9.9.826.1.26.64.1.30

CfprFabricUdldOperState0 = unknown1 = unidirectional2 = bidirectional3 = txRxLoop4 = mismatch5 = echoEmpty6 = adminDisabled · Integer32

Cisco Firepower fabric:FcoeSanPcEp:udldOperState managed object property

cfprFabricFcoeSanPcEpWarnings

1.3.6.1.4.1.9.9.826.1.26.64.1.31

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcoeSanPcEp:warnings managed object property

cfprFabricFcoeVsanPcTable

1.3.6.1.4.1.9.9.826.1.26.65

Index: cfprFabricFcoeVsanPcInstanceId

Cisco Firepower fabric:FcoeVsanPc managed object table

cfprFabricFcoeVsanPcInstanceId

1.3.6.1.4.1.9.9.826.1.26.65.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcoeVsanPcDn

1.3.6.1.4.1.9.9.826.1.26.65.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcoeVsanPc:dn managed object property

cfprFabricFcoeVsanPcRn

1.3.6.1.4.1.9.9.826.1.26.65.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPc:rn managed object property

cfprFabricFcoeVsanPcAdminState

1.3.6.1.4.1.9.9.826.1.26.65.1.4

CfprFabricCIoEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcoeVsanPc:adminState managed object property

cfprFabricFcoeVsanPcDescr

1.3.6.1.4.1.9.9.826.1.26.65.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPc:descr managed object property

cfprFabricFcoeVsanPcEpDn

1.3.6.1.4.1.9.9.826.1.26.65.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPc:epDn managed object property

cfprFabricFcoeVsanPcFltAggr

1.3.6.1.4.1.9.9.826.1.26.65.1.7

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeVsanPc:fltAggr managed object property

cfprFabricFcoeVsanPcIfRole

1.3.6.1.4.1.9.9.826.1.26.65.1.8

CfprFabricSanPcIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcoeVsanPc:ifRole managed object property

cfprFabricFcoeVsanPcIfType

1.3.6.1.4.1.9.9.826.1.26.65.1.9

CfprFabricCIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcoeVsanPc:ifType managed object property

cfprFabricFcoeVsanPcLocale

1.3.6.1.4.1.9.9.826.1.26.65.1.10

CfprFabricExternalPcLocale · BITS

Cisco Firepower fabric:FcoeVsanPc:locale managed object property

cfprFabricFcoeVsanPcName

1.3.6.1.4.1.9.9.826.1.26.65.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPc:name managed object property

cfprFabricFcoeVsanPcOperState

1.3.6.1.4.1.9.9.826.1.26.65.1.12

CfprNetworkPortOperState0 = indeterminate1 = up2 = adminDown3 = linkDown4 = failed5 = noLicense6 = linkUp7 = hardwareFailure8 = softwareFailure9 = errorDisabled10 = sfpNotPresent11 = udldAggrDown · Integer32

Cisco Firepower fabric:FcoeVsanPc:operState managed object property

cfprFabricFcoeVsanPcPeerDn

1.3.6.1.4.1.9.9.826.1.26.65.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPc:peerDn managed object property

cfprFabricFcoeVsanPcPortId

1.3.6.1.4.1.9.9.826.1.26.65.1.14

Gauge32

Cisco Firepower fabric:FcoeVsanPc:portId managed object property

cfprFabricFcoeVsanPcStateQual

1.3.6.1.4.1.9.9.826.1.26.65.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPc:stateQual managed object property

cfprFabricFcoeVsanPcSwitchId

1.3.6.1.4.1.9.9.826.1.26.65.1.16

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcoeVsanPc:switchId managed object property

cfprFabricFcoeVsanPcTransport

1.3.6.1.4.1.9.9.826.1.26.65.1.17

CfprFabricFcoeVsanPcTransport · BITS

Cisco Firepower fabric:FcoeVsanPc:transport managed object property

cfprFabricFcoeVsanPcType

1.3.6.1.4.1.9.9.826.1.26.65.1.18

CfprFabricSanPcType · BITS

Cisco Firepower fabric:FcoeVsanPc:type managed object property

cfprFabricFcoeVsanPcWarnings

1.3.6.1.4.1.9.9.826.1.26.65.1.19

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcoeVsanPc:warnings managed object property

cfprFabricFcoeVsanPortEpTable

1.3.6.1.4.1.9.9.826.1.26.66

Index: cfprFabricFcoeVsanPortEpInstanceId

Cisco Firepower fabric:FcoeVsanPortEp managed object table

cfprFabricFcoeVsanPortEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.66.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricFcoeVsanPortEpDn

1.3.6.1.4.1.9.9.826.1.26.66.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:FcoeVsanPortEp:dn managed object property

cfprFabricFcoeVsanPortEpRn

1.3.6.1.4.1.9.9.826.1.26.66.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPortEp:rn managed object property

cfprFabricFcoeVsanPortEpAdminState

1.3.6.1.4.1.9.9.826.1.26.66.1.4

CfprFabricExternalEpAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:FcoeVsanPortEp:adminState managed object property

cfprFabricFcoeVsanPortEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.66.1.5

Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:aggrPortId managed object property

cfprFabricFcoeVsanPortEpChassisId

1.3.6.1.4.1.9.9.826.1.26.66.1.6

Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:chassisId managed object property

cfprFabricFcoeVsanPortEpEpDn

1.3.6.1.4.1.9.9.826.1.26.66.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPortEp:epDn managed object property

cfprFabricFcoeVsanPortEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.66.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeVsanPortEp:fltAggr managed object property

cfprFabricFcoeVsanPortEpIfRole

1.3.6.1.4.1.9.9.826.1.26.66.1.9

CfprFabricSanEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:FcoeVsanPortEp:ifRole managed object property

cfprFabricFcoeVsanPortEpIfType

1.3.6.1.4.1.9.9.826.1.26.66.1.10

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:FcoeVsanPortEp:ifType managed object property

cfprFabricFcoeVsanPortEpLicGP

1.3.6.1.4.1.9.9.826.1.26.66.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:FcoeVsanPortEp:licGP managed object property

cfprFabricFcoeVsanPortEpLicState

1.3.6.1.4.1.9.9.826.1.26.66.1.12

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:FcoeVsanPortEp:licState managed object property

cfprFabricFcoeVsanPortEpLocale

1.3.6.1.4.1.9.9.826.1.26.66.1.13

CfprFabricExternalEpLocale · BITS

Cisco Firepower fabric:FcoeVsanPortEp:locale managed object property

cfprFabricFcoeVsanPortEpName

1.3.6.1.4.1.9.9.826.1.26.66.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPortEp:name managed object property

cfprFabricFcoeVsanPortEpOperState

1.3.6.1.4.1.9.9.826.1.26.66.1.15

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:FcoeVsanPortEp:operState managed object property

cfprFabricFcoeVsanPortEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.66.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPortEp:operStateReason managed object property

cfprFabricFcoeVsanPortEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.66.1.17

Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:peerAggrPortId managed object property

cfprFabricFcoeVsanPortEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.66.1.18

Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:peerChassisId managed object property

cfprFabricFcoeVsanPortEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.66.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:FcoeVsanPortEp:peerDn managed object property

cfprFabricFcoeVsanPortEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.66.1.20

Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:peerPortId managed object property

cfprFabricFcoeVsanPortEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.66.1.21

Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:peerSlotId managed object property

cfprFabricFcoeVsanPortEpPortId

1.3.6.1.4.1.9.9.826.1.26.66.1.22

CfprFabricFcoeVsanPortEpPortId (1..256) · Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:portId managed object property

cfprFabricFcoeVsanPortEpSlotId

1.3.6.1.4.1.9.9.826.1.26.66.1.23

CfprFabricFcoeVsanPortEpSlotId (1..5) · Gauge32

Cisco Firepower fabric:FcoeVsanPortEp:slotId managed object property

cfprFabricFcoeVsanPortEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.66.1.24

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:FcoeVsanPortEp:switchId managed object property

cfprFabricFcoeVsanPortEpTransport

1.3.6.1.4.1.9.9.826.1.26.66.1.25

CfprFabricAFcSanEpTransport · BITS

Cisco Firepower fabric:FcoeVsanPortEp:transport managed object property

cfprFabricFcoeVsanPortEpType

1.3.6.1.4.1.9.9.826.1.26.66.1.26

CfprFabricSanEpType · BITS

Cisco Firepower fabric:FcoeVsanPortEp:type managed object property

cfprFabricFcoeVsanPortEpWarnings

1.3.6.1.4.1.9.9.826.1.26.66.1.27

CfprFabricWarnings · BITS

Cisco Firepower fabric:FcoeVsanPortEp:warnings managed object property

cfprFabricIfTable

1.3.6.1.4.1.9.9.826.1.26.69

Index: cfprFabricIfInstanceId

Cisco Firepower fabric:If managed object table

cfprFabricIfInstanceId

1.3.6.1.4.1.9.9.826.1.26.69.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricIfDn

1.3.6.1.4.1.9.9.826.1.26.69.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:If:dn managed object property

cfprFabricIfRn

1.3.6.1.4.1.9.9.826.1.26.69.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:If:rn managed object property

cfprFabricIfAddr

1.3.6.1.4.1.9.9.826.1.26.69.1.4

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower fabric:If:addr managed object property

cfprFabricIfId

1.3.6.1.4.1.9.9.826.1.26.69.1.5

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:If:id managed object property

cfprFabricLacpPolicyTable

1.3.6.1.4.1.9.9.826.1.26.70

Index: cfprFabricLacpPolicyInstanceId

Cisco Firepower fabric:LacpPolicy managed object table

cfprFabricLacpPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.26.70.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLacpPolicyDn

1.3.6.1.4.1.9.9.826.1.26.70.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LacpPolicy:dn managed object property

cfprFabricLacpPolicyRn

1.3.6.1.4.1.9.9.826.1.26.70.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LacpPolicy:rn managed object property

cfprFabricLacpPolicyDescr

1.3.6.1.4.1.9.9.826.1.26.70.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LacpPolicy:descr managed object property

cfprFabricLacpPolicyFastTimer

1.3.6.1.4.1.9.9.826.1.26.70.1.5

CfprFabricLacpRate0 = normal1 = fast · Integer32

Cisco Firepower fabric:LacpPolicy:fastTimer managed object property

cfprFabricLacpPolicyIntId

1.3.6.1.4.1.9.9.826.1.26.70.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LacpPolicy:intId managed object property

cfprFabricLacpPolicyName

1.3.6.1.4.1.9.9.826.1.26.70.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LacpPolicy:name managed object property

cfprFabricLacpPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.70.1.8

Gauge32

Cisco Firepower fabric:LacpPolicy:policyLevel managed object property

cfprFabricLacpPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.70.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:LacpPolicy:policyOwner managed object property

cfprFabricLacpPolicySuspendIndividual

1.3.6.1.4.1.9.9.826.1.26.70.1.10

CfprFabricLacpSuspend0 = false1 = true · Integer32

Cisco Firepower fabric:LacpPolicy:suspendIndividual managed object property

cfprFabricLanAccessMgrTable

1.3.6.1.4.1.9.9.826.1.26.71

Index: cfprFabricLanAccessMgrInstanceId

Cisco Firepower fabric:LanAccessMgr managed object table

cfprFabricLanAccessMgrInstanceId

1.3.6.1.4.1.9.9.826.1.26.71.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanAccessMgrDn

1.3.6.1.4.1.9.9.826.1.26.71.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanAccessMgr:dn managed object property

cfprFabricLanAccessMgrRn

1.3.6.1.4.1.9.9.826.1.26.71.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanAccessMgr:rn managed object property

cfprFabricLanCloudTable

1.3.6.1.4.1.9.9.826.1.26.72

Index: cfprFabricLanCloudInstanceId

Cisco Firepower fabric:LanCloud managed object table

cfprFabricLanCloudInstanceId

1.3.6.1.4.1.9.9.826.1.26.72.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanCloudDn

1.3.6.1.4.1.9.9.826.1.26.72.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanCloud:dn managed object property

cfprFabricLanCloudRn

1.3.6.1.4.1.9.9.826.1.26.72.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloud:rn managed object property

cfprFabricLanCloudFsmDescr

1.3.6.1.4.1.9.9.826.1.26.72.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloud:fsmDescr managed object property

cfprFabricLanCloudFsmPrev

1.3.6.1.4.1.9.9.826.1.26.72.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloud:fsmPrev managed object property

cfprFabricLanCloudFsmProgr

1.3.6.1.4.1.9.9.826.1.26.72.1.6

Gauge32

Cisco Firepower fabric:LanCloud:fsmProgr managed object property

cfprFabricLanCloudFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.26.72.1.7

Gauge32

Cisco Firepower fabric:LanCloud:fsmRmtInvErrCode managed object property

cfprFabricLanCloudFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.26.72.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloud:fsmRmtInvErrDescr managed object property

cfprFabricLanCloudFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.26.72.1.9

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:LanCloud:fsmRmtInvRslt managed object property

cfprFabricLanCloudFsmStageDescr

1.3.6.1.4.1.9.9.826.1.26.72.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloud:fsmStageDescr managed object property

cfprFabricLanCloudFsmStamp

1.3.6.1.4.1.9.9.826.1.26.72.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:LanCloud:fsmStamp managed object property

cfprFabricLanCloudFsmStatus

1.3.6.1.4.1.9.9.826.1.26.72.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloud:fsmStatus managed object property

cfprFabricLanCloudFsmTry

1.3.6.1.4.1.9.9.826.1.26.72.1.13

Gauge32

Cisco Firepower fabric:LanCloud:fsmTry managed object property

cfprFabricLanCloudMacAging

1.3.6.1.4.1.9.9.826.1.26.72.1.14

TimeIntervalSecA period of time, measured in units of 1 second. · Unsigned32

Cisco Firepower fabric:LanCloud:macAging managed object property

cfprFabricLanCloudMode

1.3.6.1.4.1.9.9.826.1.26.72.1.15

CfprFabricSwitchingMode0 = endHost1 = switch2 = securityNode · Integer32

Cisco Firepower fabric:LanCloud:mode managed object property

cfprFabricLanCloudVlanCompression

1.3.6.1.4.1.9.9.826.1.26.72.1.16

CfprFabricLanCloudVlanCompression1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:LanCloud:vlanCompression managed object property

cfprFabricLanCloudFsmTable

1.3.6.1.4.1.9.9.826.1.26.73

Index: cfprFabricLanCloudFsmInstanceId

Cisco Firepower fabric:LanCloudFsm managed object table

cfprFabricLanCloudFsmInstanceId

1.3.6.1.4.1.9.9.826.1.26.73.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanCloudFsmDn

1.3.6.1.4.1.9.9.826.1.26.73.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanCloudFsm:dn managed object property

cfprFabricLanCloudFsmRn

1.3.6.1.4.1.9.9.826.1.26.73.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloudFsm:rn managed object property

cfprFabricLanCloudFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.26.73.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:LanCloudFsm:completionTime managed object property

cfprFabricLanCloudFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.26.73.1.5

CfprFabricLanCloudFsmCurrentFsm0 = nop184 = switchMode · Integer32

Cisco Firepower fabric:LanCloudFsm:currentFsm managed object property

cfprFabricLanCloudFsmDescrData

1.3.6.1.4.1.9.9.826.1.26.73.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloudFsm:descr managed object property

cfprFabricLanCloudFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.26.73.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:LanCloudFsm:fsmStatus managed object property

cfprFabricLanCloudFsmProgress

1.3.6.1.4.1.9.9.826.1.26.73.1.8

Gauge32

Cisco Firepower fabric:LanCloudFsm:progress managed object property

cfprFabricLanCloudFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.26.73.1.9

Gauge32

Cisco Firepower fabric:LanCloudFsm:rmtErrCode managed object property

cfprFabricLanCloudFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.26.73.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloudFsm:rmtErrDescr managed object property

cfprFabricLanCloudFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.26.73.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:LanCloudFsm:rmtRslt managed object property

cfprFabricLanCloudFsmStageTable

1.3.6.1.4.1.9.9.826.1.26.74

Index: cfprFabricLanCloudFsmStageInstanceId

Cisco Firepower fabric:LanCloudFsmStage managed object table

cfprFabricLanCloudFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.26.74.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanCloudFsmStageDn

1.3.6.1.4.1.9.9.826.1.26.74.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanCloudFsmStage:dn managed object property

cfprFabricLanCloudFsmStageRn

1.3.6.1.4.1.9.9.826.1.26.74.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloudFsmStage:rn managed object property

cfprFabricLanCloudFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.26.74.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloudFsmStage:descr managed object property

cfprFabricLanCloudFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.26.74.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:LanCloudFsmStage:lastUpdateTime managed object property

cfprFabricLanCloudFsmStageName

1.3.6.1.4.1.9.9.826.1.26.74.1.6

CfprFabricLanCloudFsmStageName0 = nop184 = switchModeBegin185 = switchModeSwConfigPeer186 = switchModeSwConfigLocal392 = switchModeFail393 = switchModeSuccess · Integer32

Cisco Firepower fabric:LanCloudFsmStage:name managed object property

cfprFabricLanCloudFsmStageOrder

1.3.6.1.4.1.9.9.826.1.26.74.1.7

Gauge32

Cisco Firepower fabric:LanCloudFsmStage:order managed object property

cfprFabricLanCloudFsmStageRetry

1.3.6.1.4.1.9.9.826.1.26.74.1.8

Gauge32

Cisco Firepower fabric:LanCloudFsmStage:retry managed object property

cfprFabricLanCloudFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.26.74.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:LanCloudFsmStage:stageStatus managed object property

cfprFabricLanCloudFsmTaskTable

1.3.6.1.4.1.9.9.826.1.26.75

Index: cfprFabricLanCloudFsmTaskInstanceId

Cisco Firepower fabric:LanCloudFsmTask managed object table

cfprFabricLanCloudFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.26.75.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanCloudFsmTaskDn

1.3.6.1.4.1.9.9.826.1.26.75.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanCloudFsmTask:dn managed object property

cfprFabricLanCloudFsmTaskRn

1.3.6.1.4.1.9.9.826.1.26.75.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanCloudFsmTask:rn managed object property

cfprFabricLanCloudFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.26.75.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower fabric:LanCloudFsmTask:completion managed object property

cfprFabricLanCloudFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.26.75.1.5

CfprFsmFlags · BITS

Cisco Firepower fabric:LanCloudFsmTask:flags managed object property

cfprFabricLanCloudFsmTaskItem

1.3.6.1.4.1.9.9.826.1.26.75.1.6

CfprFabricLanCloudFsmTaskItem0 = nop184 = switchMode · Integer32

Cisco Firepower fabric:LanCloudFsmTask:item managed object property

cfprFabricLanCloudFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.26.75.1.7

Gauge32

Cisco Firepower fabric:LanCloudFsmTask:seqId managed object property

cfprFabricLanMonCloudTable

1.3.6.1.4.1.9.9.826.1.26.76

Index: cfprFabricLanMonCloudInstanceId

Cisco Firepower fabric:LanMonCloud managed object table

cfprFabricLanMonCloudInstanceId

1.3.6.1.4.1.9.9.826.1.26.76.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanMonCloudDn

1.3.6.1.4.1.9.9.826.1.26.76.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanMonCloud:dn managed object property

cfprFabricLanMonCloudRn

1.3.6.1.4.1.9.9.826.1.26.76.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanMonCloud:rn managed object property

cfprFabricLanMonCloudMode

1.3.6.1.4.1.9.9.826.1.26.76.1.4

CfprFabricSwitchingMode0 = endHost1 = switch2 = securityNode · Integer32

Cisco Firepower fabric:LanMonCloud:mode managed object property

cfprFabricLanPinGroupTable

1.3.6.1.4.1.9.9.826.1.26.77

Index: cfprFabricLanPinGroupInstanceId

Cisco Firepower fabric:LanPinGroup managed object table

cfprFabricLanPinGroupInstanceId

1.3.6.1.4.1.9.9.826.1.26.77.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanPinGroupDn

1.3.6.1.4.1.9.9.826.1.26.77.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanPinGroup:dn managed object property

cfprFabricLanPinGroupRn

1.3.6.1.4.1.9.9.826.1.26.77.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinGroup:rn managed object property

cfprFabricLanPinGroupDescr

1.3.6.1.4.1.9.9.826.1.26.77.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinGroup:descr managed object property

cfprFabricLanPinGroupIntId

1.3.6.1.4.1.9.9.826.1.26.77.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinGroup:intId managed object property

cfprFabricLanPinGroupName

1.3.6.1.4.1.9.9.826.1.26.77.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinGroup:name managed object property

cfprFabricLanPinGroupPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.77.1.7

Gauge32

Cisco Firepower fabric:LanPinGroup:policyLevel managed object property

cfprFabricLanPinGroupPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.77.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:LanPinGroup:policyOwner managed object property

cfprFabricLanPinGroupSize

1.3.6.1.4.1.9.9.826.1.26.77.1.9

Gauge32

Cisco Firepower fabric:LanPinGroup:size managed object property

cfprFabricLanPinTargetTable

1.3.6.1.4.1.9.9.826.1.26.78

Index: cfprFabricLanPinTargetInstanceId

Cisco Firepower fabric:LanPinTarget managed object table

cfprFabricLanPinTargetInstanceId

1.3.6.1.4.1.9.9.826.1.26.78.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLanPinTargetDn

1.3.6.1.4.1.9.9.826.1.26.78.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LanPinTarget:dn managed object property

cfprFabricLanPinTargetRn

1.3.6.1.4.1.9.9.826.1.26.78.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinTarget:rn managed object property

cfprFabricLanPinTargetEpDn

1.3.6.1.4.1.9.9.826.1.26.78.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinTarget:epDn managed object property

cfprFabricLanPinTargetFabricId

1.3.6.1.4.1.9.9.826.1.26.78.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LanPinTarget:fabricId managed object property

cfprFabricLanPinTargetTargetStatus

1.3.6.1.4.1.9.9.826.1.26.78.1.6

CfprFabricTargetStatus0 = valid1 = invalid · Integer32

Cisco Firepower fabric:LanPinTarget:targetStatus managed object property

cfprFabricLastAckedSlotTable

1.3.6.1.4.1.9.9.826.1.26.79

Index: cfprFabricLastAckedSlotInstanceId

Cisco Firepower fabric:LastAckedSlot managed object table

cfprFabricLastAckedSlotInstanceId

1.3.6.1.4.1.9.9.826.1.26.79.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLastAckedSlotDn

1.3.6.1.4.1.9.9.826.1.26.79.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:LastAckedSlot:dn managed object property

cfprFabricLastAckedSlotRn

1.3.6.1.4.1.9.9.826.1.26.79.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:LastAckedSlot:rn managed object property

cfprFabricLastAckedSlotBoardAggregationRole

1.3.6.1.4.1.9.9.826.1.26.79.1.4

CfprEquipmentBoardAggregationRole0 = none1 = single2 = multiMaster3 = multiSlave · Integer32

Cisco Firepower fabric:LastAckedSlot:boardAggregationRole managed object property

cfprFabricLastAckedSlotChassisId

1.3.6.1.4.1.9.9.826.1.26.79.1.5

Gauge32

Cisco Firepower fabric:LastAckedSlot:chassisId managed object property

cfprFabricLastAckedSlotSlotId

1.3.6.1.4.1.9.9.826.1.26.79.1.6

Gauge32

Cisco Firepower fabric:LastAckedSlot:slotId managed object property

cfprFabricLastAckedSlotSwitchId

1.3.6.1.4.1.9.9.826.1.26.79.1.7

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:LastAckedSlot:switchId managed object property

cfprFabricLocaleTable

1.3.6.1.4.1.9.9.826.1.26.80

Index: cfprFabricLocaleInstanceId

Cisco Firepower fabric:Locale managed object table

cfprFabricLocaleInstanceId

1.3.6.1.4.1.9.9.826.1.26.80.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricLocaleDn

1.3.6.1.4.1.9.9.826.1.26.80.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Locale:dn managed object property

cfprFabricLocaleRn

1.3.6.1.4.1.9.9.826.1.26.80.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Locale:rn managed object property

cfprFabricLocaleCType

1.3.6.1.4.1.9.9.826.1.26.80.1.4

Gauge32

Cisco Firepower fabric:Locale:cType managed object property

cfprFabricLocaleChassisId

1.3.6.1.4.1.9.9.826.1.26.80.1.5

Gauge32

Cisco Firepower fabric:Locale:chassisId managed object property

cfprFabricLocaleLocale

1.3.6.1.4.1.9.9.826.1.26.80.1.6

CfprNetworkLocale · BITS

Cisco Firepower fabric:Locale:locale managed object property

cfprFabricLocaleName

1.3.6.1.4.1.9.9.826.1.26.80.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Locale:name managed object property

cfprFabricLocaleSide

1.3.6.1.4.1.9.9.826.1.26.80.1.8

CfprNetworkSide0 = left1 = right · Integer32

Cisco Firepower fabric:Locale:side managed object property

cfprFabricLocaleSlotId

1.3.6.1.4.1.9.9.826.1.26.80.1.9

Gauge32

Cisco Firepower fabric:Locale:slotId managed object property

cfprFabricLocaleSwitchId

1.3.6.1.4.1.9.9.826.1.26.80.1.10

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:Locale:switchId managed object property

cfprFabricLocaleTransport

1.3.6.1.4.1.9.9.826.1.26.80.1.11

CfprNetworkTransport · BITS

Cisco Firepower fabric:Locale:transport managed object property

cfprFabricLocaleType

1.3.6.1.4.1.9.9.826.1.26.80.1.12

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:Locale:type managed object property

cfprFabricMulticastPolicyTable

1.3.6.1.4.1.9.9.826.1.26.81

Index: cfprFabricMulticastPolicyInstanceId

Cisco Firepower fabric:MulticastPolicy managed object table

cfprFabricMulticastPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.26.81.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricMulticastPolicyDn

1.3.6.1.4.1.9.9.826.1.26.81.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:MulticastPolicy:dn managed object property

cfprFabricMulticastPolicyRn

1.3.6.1.4.1.9.9.826.1.26.81.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:MulticastPolicy:rn managed object property

cfprFabricMulticastPolicyDescr

1.3.6.1.4.1.9.9.826.1.26.81.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:MulticastPolicy:descr managed object property

cfprFabricMulticastPolicyIntId

1.3.6.1.4.1.9.9.826.1.26.81.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:MulticastPolicy:intId managed object property

cfprFabricMulticastPolicyName

1.3.6.1.4.1.9.9.826.1.26.81.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:MulticastPolicy:name managed object property

cfprFabricMulticastPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.81.1.7

Gauge32

Cisco Firepower fabric:MulticastPolicy:policyLevel managed object property

cfprFabricMulticastPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.81.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:MulticastPolicy:policyOwner managed object property

cfprFabricMulticastPolicyQuerierIpAddr

1.3.6.1.4.1.9.9.826.1.26.81.1.9

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower fabric:MulticastPolicy:querierIpAddr managed object property

cfprFabricMulticastPolicyQuerierState

1.3.6.1.4.1.9.9.826.1.26.81.1.10

CfprFabricQuerierType0 = enabled1 = disabled · Integer32

Cisco Firepower fabric:MulticastPolicy:querierState managed object property

cfprFabricMulticastPolicySnoopingState

1.3.6.1.4.1.9.9.826.1.26.81.1.11

CfprFabricSnoopingType0 = enabled1 = disabled · Integer32

Cisco Firepower fabric:MulticastPolicy:snoopingState managed object property

cfprFabricNetGroupTable

1.3.6.1.4.1.9.9.826.1.26.82

Index: cfprFabricNetGroupInstanceId

Cisco Firepower fabric:NetGroup managed object table

cfprFabricNetGroupInstanceId

1.3.6.1.4.1.9.9.826.1.26.82.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricNetGroupDn

1.3.6.1.4.1.9.9.826.1.26.82.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:NetGroup:dn managed object property

cfprFabricNetGroupRn

1.3.6.1.4.1.9.9.826.1.26.82.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:rn managed object property

cfprFabricNetGroupAssigned

1.3.6.1.4.1.9.9.826.1.26.82.1.4

Gauge32

Cisco Firepower fabric:NetGroup:assigned managed object property

cfprFabricNetGroupAssignmentOrder

1.3.6.1.4.1.9.9.826.1.26.82.1.5

CfprPoolPoolAssignmentOrder0 = default1 = sequential · Integer32

Cisco Firepower fabric:NetGroup:assignmentOrder managed object property

cfprFabricNetGroupDescr

1.3.6.1.4.1.9.9.826.1.26.82.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:descr managed object property

cfprFabricNetGroupId

1.3.6.1.4.1.9.9.826.1.26.82.1.7

Gauge32

Cisco Firepower fabric:NetGroup:id managed object property

cfprFabricNetGroupIntId

1.3.6.1.4.1.9.9.826.1.26.82.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:intId managed object property

cfprFabricNetGroupName

1.3.6.1.4.1.9.9.826.1.26.82.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:name managed object property

cfprFabricNetGroupNativeNet

1.3.6.1.4.1.9.9.826.1.26.82.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:nativeNet managed object property

cfprFabricNetGroupNativeNetDn

1.3.6.1.4.1.9.9.826.1.26.82.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:nativeNetDn managed object property

cfprFabricNetGroupOwner

1.3.6.1.4.1.9.9.826.1.26.82.1.12

CfprFabricOwner1 = policy2 = management · Integer32

Cisco Firepower fabric:NetGroup:owner managed object property

cfprFabricNetGroupPeerDn

1.3.6.1.4.1.9.9.826.1.26.82.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:NetGroup:peerDn managed object property

cfprFabricNetGroupPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.82.1.14

Gauge32

Cisco Firepower fabric:NetGroup:policyLevel managed object property

cfprFabricNetGroupPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.82.1.15

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:NetGroup:policyOwner managed object property

cfprFabricNetGroupSize

1.3.6.1.4.1.9.9.826.1.26.82.1.16

Gauge32

Cisco Firepower fabric:NetGroup:size managed object property

cfprFabricNetGroupSwitchId

1.3.6.1.4.1.9.9.826.1.26.82.1.17

CfprFabricNetGroupSwitchId0 = none1 = a2 = b3 = dual · Integer32

Cisco Firepower fabric:NetGroup:switchId managed object property

cfprFabricNetGroupType

1.3.6.1.4.1.9.9.826.1.26.82.1.18

CfprFabricNetGroupType · BITS

Cisco Firepower fabric:NetGroup:type managed object property

cfprFabricOrgVlanPolicyTable

1.3.6.1.4.1.9.9.826.1.26.93

Index: cfprFabricOrgVlanPolicyInstanceId

Cisco Firepower fabric:OrgVlanPolicy managed object table

cfprFabricOrgVlanPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.26.93.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricOrgVlanPolicyDn

1.3.6.1.4.1.9.9.826.1.26.93.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:OrgVlanPolicy:dn managed object property

cfprFabricOrgVlanPolicyRn

1.3.6.1.4.1.9.9.826.1.26.93.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:OrgVlanPolicy:rn managed object property

cfprFabricOrgVlanPolicyAdminState

1.3.6.1.4.1.9.9.826.1.26.93.1.4

CfprFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:OrgVlanPolicy:adminState managed object property

cfprFabricOrgVlanPolicyName

1.3.6.1.4.1.9.9.826.1.26.93.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:OrgVlanPolicy:name managed object property

cfprFabricPathTable

1.3.6.1.4.1.9.9.826.1.26.94

Index: cfprFabricPathInstanceId

Cisco Firepower fabric:Path managed object table

cfprFabricPathInstanceId

1.3.6.1.4.1.9.9.826.1.26.94.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricPathDn

1.3.6.1.4.1.9.9.826.1.26.94.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Path:dn managed object property

cfprFabricPathRn

1.3.6.1.4.1.9.9.826.1.26.94.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Path:rn managed object property

cfprFabricPathCType

1.3.6.1.4.1.9.9.826.1.26.94.1.4

Gauge32

Cisco Firepower fabric:Path:cType managed object property

cfprFabricPathChassisId

1.3.6.1.4.1.9.9.826.1.26.94.1.5

Gauge32

Cisco Firepower fabric:Path:chassisId managed object property

cfprFabricPathEnacp

1.3.6.1.4.1.9.9.826.1.26.94.1.6

Gauge32

Cisco Firepower fabric:Path:enacp managed object property

cfprFabricPathId

1.3.6.1.4.1.9.9.826.1.26.94.1.7

Gauge32

Cisco Firepower fabric:Path:id managed object property

cfprFabricPathLocale

1.3.6.1.4.1.9.9.826.1.26.94.1.8

CfprNetworkLocale · BITS

Cisco Firepower fabric:Path:locale managed object property

cfprFabricPathName

1.3.6.1.4.1.9.9.826.1.26.94.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Path:name managed object property

cfprFabricPathNsSize

1.3.6.1.4.1.9.9.826.1.26.94.1.10

Gauge32

Cisco Firepower fabric:Path:nsSize managed object property

cfprFabricPathSide

1.3.6.1.4.1.9.9.826.1.26.94.1.11

CfprNetworkSide0 = left1 = right · Integer32

Cisco Firepower fabric:Path:side managed object property

cfprFabricPathSwitchId

1.3.6.1.4.1.9.9.826.1.26.94.1.12

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:Path:switchId managed object property

cfprFabricPathTransport

1.3.6.1.4.1.9.9.826.1.26.94.1.13

CfprNetworkTransport · BITS

Cisco Firepower fabric:Path:transport managed object property

cfprFabricPathType

1.3.6.1.4.1.9.9.826.1.26.94.1.14

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:Path:type managed object property

cfprFabricPathConnTable

1.3.6.1.4.1.9.9.826.1.26.95

Index: cfprFabricPathConnInstanceId

Cisco Firepower fabric:PathConn managed object table

cfprFabricPathConnInstanceId

1.3.6.1.4.1.9.9.826.1.26.95.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricPathConnDn

1.3.6.1.4.1.9.9.826.1.26.95.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:PathConn:dn managed object property

cfprFabricPathConnRn

1.3.6.1.4.1.9.9.826.1.26.95.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PathConn:rn managed object property

cfprFabricPathConnCType

1.3.6.1.4.1.9.9.826.1.26.95.1.4

Gauge32

Cisco Firepower fabric:PathConn:cType managed object property

cfprFabricPathConnLocale

1.3.6.1.4.1.9.9.826.1.26.95.1.5

CfprNetworkLocale · BITS

Cisco Firepower fabric:PathConn:locale managed object property

cfprFabricPathConnName

1.3.6.1.4.1.9.9.826.1.26.95.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PathConn:name managed object property

cfprFabricPathConnTransport

1.3.6.1.4.1.9.9.826.1.26.95.1.7

CfprNetworkTransport · BITS

Cisco Firepower fabric:PathConn:transport managed object property

cfprFabricPathConnType

1.3.6.1.4.1.9.9.826.1.26.95.1.8

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:PathConn:type managed object property

cfprFabricPathEpTable

1.3.6.1.4.1.9.9.826.1.26.96

Index: cfprFabricPathEpInstanceId

Cisco Firepower fabric:PathEp managed object table

cfprFabricPathEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.96.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricPathEpDn

1.3.6.1.4.1.9.9.826.1.26.96.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:PathEp:dn managed object property

cfprFabricPathEpRn

1.3.6.1.4.1.9.9.826.1.26.96.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PathEp:rn managed object property

cfprFabricPathEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.96.1.4

Gauge32

Cisco Firepower fabric:PathEp:aggrPortId managed object property

cfprFabricPathEpCType

1.3.6.1.4.1.9.9.826.1.26.96.1.5

Gauge32

Cisco Firepower fabric:PathEp:cType managed object property

cfprFabricPathEpChassisId

1.3.6.1.4.1.9.9.826.1.26.96.1.6

Gauge32

Cisco Firepower fabric:PathEp:chassisId managed object property

cfprFabricPathEpDiagLldpTransmit

1.3.6.1.4.1.9.9.826.1.26.96.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:PathEp:diagLldpTransmit managed object property

cfprFabricPathEpEpDn

1.3.6.1.4.1.9.9.826.1.26.96.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PathEp:epDn managed object property

cfprFabricPathEpIfRole

1.3.6.1.4.1.9.9.826.1.26.96.1.9

CfprNetworkPortRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:PathEp:ifRole managed object property

cfprFabricPathEpIfType

1.3.6.1.4.1.9.9.826.1.26.96.1.10

CfprFabricPathEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:PathEp:ifType managed object property

cfprFabricPathEpLocale

1.3.6.1.4.1.9.9.826.1.26.96.1.11

CfprFabricPathEpLocale · BITS

Cisco Firepower fabric:PathEp:locale managed object property

cfprFabricPathEpName

1.3.6.1.4.1.9.9.826.1.26.96.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PathEp:name managed object property

cfprFabricPathEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.96.1.13

Gauge32

Cisco Firepower fabric:PathEp:peerAggrPortId managed object property

cfprFabricPathEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.96.1.14

Gauge32

Cisco Firepower fabric:PathEp:peerChassisId managed object property

cfprFabricPathEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.96.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PathEp:peerDn managed object property

cfprFabricPathEpPeerMac

1.3.6.1.4.1.9.9.826.1.26.96.1.16

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower fabric:PathEp:peerMac managed object property

cfprFabricPathEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.96.1.17

Gauge32

Cisco Firepower fabric:PathEp:peerPortId managed object property

cfprFabricPathEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.96.1.18

Gauge32

Cisco Firepower fabric:PathEp:peerSlotId managed object property

cfprFabricPathEpPortId

1.3.6.1.4.1.9.9.826.1.26.96.1.19

Gauge32

Cisco Firepower fabric:PathEp:portId managed object property

cfprFabricPathEpSide

1.3.6.1.4.1.9.9.826.1.26.96.1.20

CfprNetworkSide0 = left1 = right · Integer32

Cisco Firepower fabric:PathEp:side managed object property

cfprFabricPathEpSlotId

1.3.6.1.4.1.9.9.826.1.26.96.1.21

Gauge32

Cisco Firepower fabric:PathEp:slotId managed object property

cfprFabricPathEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.96.1.22

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:PathEp:switchId managed object property

cfprFabricPathEpTransport

1.3.6.1.4.1.9.9.826.1.26.96.1.23

CfprNetworkTransport · BITS

Cisco Firepower fabric:PathEp:transport managed object property

cfprFabricPathEpType

1.3.6.1.4.1.9.9.826.1.26.96.1.24

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:PathEp:type managed object property

cfprFabricPoolableVlanTable

1.3.6.1.4.1.9.9.826.1.26.97

Index: cfprFabricPoolableVlanInstanceId

Cisco Firepower fabric:PoolableVlan managed object table

cfprFabricPoolableVlanInstanceId

1.3.6.1.4.1.9.9.826.1.26.97.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricPoolableVlanDn

1.3.6.1.4.1.9.9.826.1.26.97.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:PoolableVlan:dn managed object property

cfprFabricPoolableVlanRn

1.3.6.1.4.1.9.9.826.1.26.97.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PoolableVlan:rn managed object property

cfprFabricPoolableVlanId

1.3.6.1.4.1.9.9.826.1.26.97.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:PoolableVlan:id managed object property

cfprFabricPoolableVlanPoolDn

1.3.6.1.4.1.9.9.826.1.26.97.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PoolableVlan:poolDn managed object property

cfprFabricPooledVlanTable

1.3.6.1.4.1.9.9.826.1.26.98

Index: cfprFabricPooledVlanInstanceId

Cisco Firepower fabric:PooledVlan managed object table

cfprFabricPooledVlanInstanceId

1.3.6.1.4.1.9.9.826.1.26.98.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricPooledVlanDn

1.3.6.1.4.1.9.9.826.1.26.98.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:PooledVlan:dn managed object property

cfprFabricPooledVlanRn

1.3.6.1.4.1.9.9.826.1.26.98.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PooledVlan:rn managed object property

cfprFabricPooledVlanAssigned

1.3.6.1.4.1.9.9.826.1.26.98.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:PooledVlan:assigned managed object property

cfprFabricPooledVlanAssignedToDn

1.3.6.1.4.1.9.9.826.1.26.98.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PooledVlan:assignedToDn managed object property

cfprFabricPooledVlanConfigIssues

1.3.6.1.4.1.9.9.826.1.26.98.1.6

CfprFabricPoolMemberConfigIssues · BITS

Cisco Firepower fabric:PooledVlan:configIssues managed object property

cfprFabricPooledVlanName

1.3.6.1.4.1.9.9.826.1.26.98.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PooledVlan:name managed object property

cfprFabricPooledVlanPeerDn

1.3.6.1.4.1.9.9.826.1.26.98.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PooledVlan:peerDn managed object property

cfprFabricPooledVlanPoolableDn

1.3.6.1.4.1.9.9.826.1.26.98.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PooledVlan:poolableDn managed object property

cfprFabricPooledVlanPrevAssignedToDn

1.3.6.1.4.1.9.9.826.1.26.98.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:PooledVlan:prevAssignedToDn managed object property

cfprFabricSanCloudTable

1.3.6.1.4.1.9.9.826.1.26.99

Index: cfprFabricSanCloudInstanceId

Cisco Firepower fabric:SanCloud managed object table

cfprFabricSanCloudInstanceId

1.3.6.1.4.1.9.9.826.1.26.99.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSanCloudDn

1.3.6.1.4.1.9.9.826.1.26.99.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SanCloud:dn managed object property

cfprFabricSanCloudRn

1.3.6.1.4.1.9.9.826.1.26.99.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloud:rn managed object property

cfprFabricSanCloudFsmDescr

1.3.6.1.4.1.9.9.826.1.26.99.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloud:fsmDescr managed object property

cfprFabricSanCloudFsmPrev

1.3.6.1.4.1.9.9.826.1.26.99.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloud:fsmPrev managed object property

cfprFabricSanCloudFsmProgr

1.3.6.1.4.1.9.9.826.1.26.99.1.6

Gauge32

Cisco Firepower fabric:SanCloud:fsmProgr managed object property

cfprFabricSanCloudFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.26.99.1.7

Gauge32

Cisco Firepower fabric:SanCloud:fsmRmtInvErrCode managed object property

cfprFabricSanCloudFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.26.99.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloud:fsmRmtInvErrDescr managed object property

cfprFabricSanCloudFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.26.99.1.9

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:SanCloud:fsmRmtInvRslt managed object property

cfprFabricSanCloudFsmStageDescr

1.3.6.1.4.1.9.9.826.1.26.99.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloud:fsmStageDescr managed object property

cfprFabricSanCloudFsmStamp

1.3.6.1.4.1.9.9.826.1.26.99.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:SanCloud:fsmStamp managed object property

cfprFabricSanCloudFsmStatus

1.3.6.1.4.1.9.9.826.1.26.99.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloud:fsmStatus managed object property

cfprFabricSanCloudFsmTry

1.3.6.1.4.1.9.9.826.1.26.99.1.13

Gauge32

Cisco Firepower fabric:SanCloud:fsmTry managed object property

cfprFabricSanCloudMode

1.3.6.1.4.1.9.9.826.1.26.99.1.14

CfprFabricSwitchingMode0 = endHost1 = switch2 = securityNode · Integer32

Cisco Firepower fabric:SanCloud:mode managed object property

cfprFabricSanCloudFsmTable

1.3.6.1.4.1.9.9.826.1.26.100

Index: cfprFabricSanCloudFsmInstanceId

Cisco Firepower fabric:SanCloudFsm managed object table

cfprFabricSanCloudFsmInstanceId

1.3.6.1.4.1.9.9.826.1.26.100.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSanCloudFsmDn

1.3.6.1.4.1.9.9.826.1.26.100.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SanCloudFsm:dn managed object property

cfprFabricSanCloudFsmRn

1.3.6.1.4.1.9.9.826.1.26.100.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloudFsm:rn managed object property

cfprFabricSanCloudFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.26.100.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:SanCloudFsm:completionTime managed object property

cfprFabricSanCloudFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.26.100.1.5

CfprFabricSanCloudFsmCurrentFsm0 = nop871 = switchMode · Integer32

Cisco Firepower fabric:SanCloudFsm:currentFsm managed object property

cfprFabricSanCloudFsmDescrData

1.3.6.1.4.1.9.9.826.1.26.100.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloudFsm:descr managed object property

cfprFabricSanCloudFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.26.100.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:SanCloudFsm:fsmStatus managed object property

cfprFabricSanCloudFsmProgress

1.3.6.1.4.1.9.9.826.1.26.100.1.8

Gauge32

Cisco Firepower fabric:SanCloudFsm:progress managed object property

cfprFabricSanCloudFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.26.100.1.9

Gauge32

Cisco Firepower fabric:SanCloudFsm:rmtErrCode managed object property

cfprFabricSanCloudFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.26.100.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloudFsm:rmtErrDescr managed object property

cfprFabricSanCloudFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.26.100.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:SanCloudFsm:rmtRslt managed object property

cfprFabricSanCloudFsmStageTable

1.3.6.1.4.1.9.9.826.1.26.101

Index: cfprFabricSanCloudFsmStageInstanceId

Cisco Firepower fabric:SanCloudFsmStage managed object table

cfprFabricSanCloudFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.26.101.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSanCloudFsmStageDn

1.3.6.1.4.1.9.9.826.1.26.101.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SanCloudFsmStage:dn managed object property

cfprFabricSanCloudFsmStageRn

1.3.6.1.4.1.9.9.826.1.26.101.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloudFsmStage:rn managed object property

cfprFabricSanCloudFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.26.101.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloudFsmStage:descr managed object property

cfprFabricSanCloudFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.26.101.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:SanCloudFsmStage:lastUpdateTime managed object property

cfprFabricSanCloudFsmStageName

1.3.6.1.4.1.9.9.826.1.26.101.1.6

CfprFabricSanCloudFsmStageName0 = nop871 = switchModeBegin872 = switchModeSwConfigPeer873 = switchModeSwConfigLocal992 = switchModeFail993 = switchModeSuccess · Integer32

Cisco Firepower fabric:SanCloudFsmStage:name managed object property

cfprFabricSanCloudFsmStageOrder

1.3.6.1.4.1.9.9.826.1.26.101.1.7

Gauge32

Cisco Firepower fabric:SanCloudFsmStage:order managed object property

cfprFabricSanCloudFsmStageRetry

1.3.6.1.4.1.9.9.826.1.26.101.1.8

Gauge32

Cisco Firepower fabric:SanCloudFsmStage:retry managed object property

cfprFabricSanCloudFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.26.101.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:SanCloudFsmStage:stageStatus managed object property

cfprFabricSanCloudFsmTaskTable

1.3.6.1.4.1.9.9.826.1.26.102

Index: cfprFabricSanCloudFsmTaskInstanceId

Cisco Firepower fabric:SanCloudFsmTask managed object table

cfprFabricSanCloudFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.26.102.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSanCloudFsmTaskDn

1.3.6.1.4.1.9.9.826.1.26.102.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SanCloudFsmTask:dn managed object property

cfprFabricSanCloudFsmTaskRn

1.3.6.1.4.1.9.9.826.1.26.102.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanCloudFsmTask:rn managed object property

cfprFabricSanCloudFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.26.102.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower fabric:SanCloudFsmTask:completion managed object property

cfprFabricSanCloudFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.26.102.1.5

CfprFsmFlags · BITS

Cisco Firepower fabric:SanCloudFsmTask:flags managed object property

cfprFabricSanCloudFsmTaskItem

1.3.6.1.4.1.9.9.826.1.26.102.1.6

CfprFabricSanCloudFsmTaskItem0 = nop871 = switchMode · Integer32

Cisco Firepower fabric:SanCloudFsmTask:item managed object property

cfprFabricSanCloudFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.26.102.1.7

Gauge32

Cisco Firepower fabric:SanCloudFsmTask:seqId managed object property

cfprFabricSanPinGroupTable

1.3.6.1.4.1.9.9.826.1.26.104

Index: cfprFabricSanPinGroupInstanceId

Cisco Firepower fabric:SanPinGroup managed object table

cfprFabricSanPinGroupInstanceId

1.3.6.1.4.1.9.9.826.1.26.104.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSanPinGroupDn

1.3.6.1.4.1.9.9.826.1.26.104.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SanPinGroup:dn managed object property

cfprFabricSanPinGroupRn

1.3.6.1.4.1.9.9.826.1.26.104.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinGroup:rn managed object property

cfprFabricSanPinGroupDescr

1.3.6.1.4.1.9.9.826.1.26.104.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinGroup:descr managed object property

cfprFabricSanPinGroupIntId

1.3.6.1.4.1.9.9.826.1.26.104.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinGroup:intId managed object property

cfprFabricSanPinGroupName

1.3.6.1.4.1.9.9.826.1.26.104.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinGroup:name managed object property

cfprFabricSanPinGroupPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.104.1.7

Gauge32

Cisco Firepower fabric:SanPinGroup:policyLevel managed object property

cfprFabricSanPinGroupPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.104.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:SanPinGroup:policyOwner managed object property

cfprFabricSanPinGroupSize

1.3.6.1.4.1.9.9.826.1.26.104.1.9

Gauge32

Cisco Firepower fabric:SanPinGroup:size managed object property

cfprFabricSanPinTargetTable

1.3.6.1.4.1.9.9.826.1.26.105

Index: cfprFabricSanPinTargetInstanceId

Cisco Firepower fabric:SanPinTarget managed object table

cfprFabricSanPinTargetInstanceId

1.3.6.1.4.1.9.9.826.1.26.105.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSanPinTargetDn

1.3.6.1.4.1.9.9.826.1.26.105.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SanPinTarget:dn managed object property

cfprFabricSanPinTargetRn

1.3.6.1.4.1.9.9.826.1.26.105.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinTarget:rn managed object property

cfprFabricSanPinTargetEpDn

1.3.6.1.4.1.9.9.826.1.26.105.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinTarget:epDn managed object property

cfprFabricSanPinTargetFabricId

1.3.6.1.4.1.9.9.826.1.26.105.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SanPinTarget:fabricId managed object property

cfprFabricSanPinTargetTargetStatus

1.3.6.1.4.1.9.9.826.1.26.105.1.6

CfprFabricTargetStatus0 = valid1 = invalid · Integer32

Cisco Firepower fabric:SanPinTarget:targetStatus managed object property

cfprFabricSubGroupTable

1.3.6.1.4.1.9.9.826.1.26.106

Index: cfprFabricSubGroupInstanceId

Cisco Firepower fabric:SubGroup managed object table

cfprFabricSubGroupInstanceId

1.3.6.1.4.1.9.9.826.1.26.106.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSubGroupDn

1.3.6.1.4.1.9.9.826.1.26.106.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SubGroup:dn managed object property

cfprFabricSubGroupRn

1.3.6.1.4.1.9.9.826.1.26.106.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SubGroup:rn managed object property

cfprFabricSubGroupAggrPortId

1.3.6.1.4.1.9.9.826.1.26.106.1.4

CfprFabricSubGroupAggrPortId (1..48) · Gauge32

Cisco Firepower fabric:SubGroup:aggrPortId managed object property

cfprFabricSubGroupConfigState

1.3.6.1.4.1.9.9.826.1.26.106.1.5

CfprFabricSubGroupConfigState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:SubGroup:configState managed object property

cfprFabricSubGroupLicGP

1.3.6.1.4.1.9.9.826.1.26.106.1.6

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:SubGroup:licGP managed object property

cfprFabricSubGroupLicState

1.3.6.1.4.1.9.9.826.1.26.106.1.7

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:SubGroup:licState managed object property

cfprFabricSubGroupLocale

1.3.6.1.4.1.9.9.826.1.26.106.1.8

CfprNetworkLocale · BITS

Cisco Firepower fabric:SubGroup:locale managed object property

cfprFabricSubGroupName

1.3.6.1.4.1.9.9.826.1.26.106.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SubGroup:name managed object property

cfprFabricSubGroupSlotId

1.3.6.1.4.1.9.9.826.1.26.106.1.10

CfprFabricSubGroupSlotId (1..4) · Gauge32

Cisco Firepower fabric:SubGroup:slotId managed object property

cfprFabricSubGroupSwitchId

1.3.6.1.4.1.9.9.826.1.26.106.1.11

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SubGroup:switchId managed object property

cfprFabricSubGroupTransport

1.3.6.1.4.1.9.9.826.1.26.106.1.12

CfprNetworkTransport · BITS

Cisco Firepower fabric:SubGroup:transport managed object property

cfprFabricSubGroupType

1.3.6.1.4.1.9.9.826.1.26.106.1.13

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:SubGroup:type managed object property

cfprFabricSwChPhEpTable

1.3.6.1.4.1.9.9.826.1.26.107

Index: cfprFabricSwChPhEpInstanceId

Cisco Firepower fabric:SwChPhEp managed object table

cfprFabricSwChPhEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.107.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSwChPhEpDn

1.3.6.1.4.1.9.9.826.1.26.107.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SwChPhEp:dn managed object property

cfprFabricSwChPhEpRn

1.3.6.1.4.1.9.9.826.1.26.107.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:rn managed object property

cfprFabricSwChPhEpAdminState

1.3.6.1.4.1.9.9.826.1.26.107.1.4

CfprFabricSwChPhEpAdminState1 = enabled2 = disabled3 = remove · Integer32

Cisco Firepower fabric:SwChPhEp:adminState managed object property

cfprFabricSwChPhEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.107.1.5

Gauge32

Cisco Firepower fabric:SwChPhEp:aggrPortId managed object property

cfprFabricSwChPhEpChassisId

1.3.6.1.4.1.9.9.826.1.26.107.1.6

Gauge32

Cisco Firepower fabric:SwChPhEp:chassisId managed object property

cfprFabricSwChPhEpEpDn

1.3.6.1.4.1.9.9.826.1.26.107.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:epDn managed object property

cfprFabricSwChPhEpEqType

1.3.6.1.4.1.9.9.826.1.26.107.1.8

CfprEquipmentFabricEpType0 = unknown1 = chassis2 = fex3 = blade4 = rackUnit · Integer32

Cisco Firepower fabric:SwChPhEp:eqType managed object property

cfprFabricSwChPhEpFltAggr

1.3.6.1.4.1.9.9.826.1.26.107.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:SwChPhEp:fltAggr managed object property

cfprFabricSwChPhEpIfRole

1.3.6.1.4.1.9.9.826.1.26.107.1.10

CfprFabricSwChEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:SwChPhEp:ifRole managed object property

cfprFabricSwChPhEpIfType

1.3.6.1.4.1.9.9.826.1.26.107.1.11

CfprFabricPIoEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:SwChPhEp:ifType managed object property

cfprFabricSwChPhEpLc

1.3.6.1.4.1.9.9.826.1.26.107.1.12

CfprFabricLifeCycle1 = inService2 = outOfService3 = outOfServiceSlave · Integer32

Cisco Firepower fabric:SwChPhEp:lc managed object property

cfprFabricSwChPhEpLicGP

1.3.6.1.4.1.9.9.826.1.26.107.1.13

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:SwChPhEp:licGP managed object property

cfprFabricSwChPhEpLicState

1.3.6.1.4.1.9.9.826.1.26.107.1.14

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:SwChPhEp:licState managed object property

cfprFabricSwChPhEpLocale

1.3.6.1.4.1.9.9.826.1.26.107.1.15

CfprFabricInternalEpLocale · BITS

Cisco Firepower fabric:SwChPhEp:locale managed object property

cfprFabricSwChPhEpModel

1.3.6.1.4.1.9.9.826.1.26.107.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:model managed object property

cfprFabricSwChPhEpName

1.3.6.1.4.1.9.9.826.1.26.107.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:name managed object property

cfprFabricSwChPhEpOperState

1.3.6.1.4.1.9.9.826.1.26.107.1.18

CfprFabricPIoEpOperState0 = unknown1 = up2 = down3 = errorMisconfigured · Integer32

Cisco Firepower fabric:SwChPhEp:operState managed object property

cfprFabricSwChPhEpOperStateReason

1.3.6.1.4.1.9.9.826.1.26.107.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:operStateReason managed object property

cfprFabricSwChPhEpPeerAggrPortId

1.3.6.1.4.1.9.9.826.1.26.107.1.20

Gauge32

Cisco Firepower fabric:SwChPhEp:peerAggrPortId managed object property

cfprFabricSwChPhEpPeerChassisId

1.3.6.1.4.1.9.9.826.1.26.107.1.21

Gauge32

Cisco Firepower fabric:SwChPhEp:peerChassisId managed object property

cfprFabricSwChPhEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.107.1.22

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:peerDn managed object property

cfprFabricSwChPhEpPeerPortId

1.3.6.1.4.1.9.9.826.1.26.107.1.23

Gauge32

Cisco Firepower fabric:SwChPhEp:peerPortId managed object property

cfprFabricSwChPhEpPeerSlotId

1.3.6.1.4.1.9.9.826.1.26.107.1.24

Gauge32

Cisco Firepower fabric:SwChPhEp:peerSlotId managed object property

cfprFabricSwChPhEpPortId

1.3.6.1.4.1.9.9.826.1.26.107.1.25

CfprFabricPIoEpPortId (1..48) · Gauge32

Cisco Firepower fabric:SwChPhEp:portId managed object property

cfprFabricSwChPhEpRevision

1.3.6.1.4.1.9.9.826.1.26.107.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:revision managed object property

cfprFabricSwChPhEpSerial

1.3.6.1.4.1.9.9.826.1.26.107.1.27

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:serial managed object property

cfprFabricSwChPhEpSlotId

1.3.6.1.4.1.9.9.826.1.26.107.1.28

CfprFabricPIoEpSlotId (1..4) · Gauge32

Cisco Firepower fabric:SwChPhEp:slotId managed object property

cfprFabricSwChPhEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.107.1.29

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SwChPhEp:switchId managed object property

cfprFabricSwChPhEpTransport

1.3.6.1.4.1.9.9.826.1.26.107.1.30

CfprNetworkTransport · BITS

Cisco Firepower fabric:SwChPhEp:transport managed object property

cfprFabricSwChPhEpType

1.3.6.1.4.1.9.9.826.1.26.107.1.31

CfprFabricSwChEpType · BITS

Cisco Firepower fabric:SwChPhEp:type managed object property

cfprFabricSwChPhEpVendor

1.3.6.1.4.1.9.9.826.1.26.107.1.32

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwChPhEp:vendor managed object property

cfprFabricSwSubGroupTable

1.3.6.1.4.1.9.9.826.1.26.108

Index: cfprFabricSwSubGroupInstanceId

Cisco Firepower fabric:SwSubGroup managed object table

cfprFabricSwSubGroupInstanceId

1.3.6.1.4.1.9.9.826.1.26.108.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSwSubGroupDn

1.3.6.1.4.1.9.9.826.1.26.108.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SwSubGroup:dn managed object property

cfprFabricSwSubGroupRn

1.3.6.1.4.1.9.9.826.1.26.108.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwSubGroup:rn managed object property

cfprFabricSwSubGroupAggrPortId

1.3.6.1.4.1.9.9.826.1.26.108.1.4

CfprFabricSwSubGroupAggrPortId (1..48) · Gauge32

Cisco Firepower fabric:SwSubGroup:aggrPortId managed object property

cfprFabricSwSubGroupConfigState

1.3.6.1.4.1.9.9.826.1.26.108.1.5

CfprFabricSwSubGroupConfigState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:SwSubGroup:configState managed object property

cfprFabricSwSubGroupLicGP

1.3.6.1.4.1.9.9.826.1.26.108.1.6

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:SwSubGroup:licGP managed object property

cfprFabricSwSubGroupLicState

1.3.6.1.4.1.9.9.826.1.26.108.1.7

CfprLicenseState0 = unknown1 = licenseOk2 = licenseInsufficient3 = licenseGraceperiod4 = licenseExpired5 = notApplicable · Integer32

Cisco Firepower fabric:SwSubGroup:licState managed object property

cfprFabricSwSubGroupLocale

1.3.6.1.4.1.9.9.826.1.26.108.1.8

CfprNetworkLocale · BITS

Cisco Firepower fabric:SwSubGroup:locale managed object property

cfprFabricSwSubGroupName

1.3.6.1.4.1.9.9.826.1.26.108.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SwSubGroup:name managed object property

cfprFabricSwSubGroupSlotId

1.3.6.1.4.1.9.9.826.1.26.108.1.10

CfprFabricSwSubGroupSlotId (1..4) · Gauge32

Cisco Firepower fabric:SwSubGroup:slotId managed object property

cfprFabricSwSubGroupSwitchId

1.3.6.1.4.1.9.9.826.1.26.108.1.11

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SwSubGroup:switchId managed object property

cfprFabricSwSubGroupTransport

1.3.6.1.4.1.9.9.826.1.26.108.1.12

CfprNetworkTransport · BITS

Cisco Firepower fabric:SwSubGroup:transport managed object property

cfprFabricSwSubGroupType

1.3.6.1.4.1.9.9.826.1.26.108.1.13

CfprNetworkConnectionType · BITS

Cisco Firepower fabric:SwSubGroup:type managed object property

cfprFabricUdldLinkPolicyTable

1.3.6.1.4.1.9.9.826.1.26.109

Index: cfprFabricUdldLinkPolicyInstanceId

Cisco Firepower fabric:UdldLinkPolicy managed object table

cfprFabricUdldLinkPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.26.109.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricUdldLinkPolicyDn

1.3.6.1.4.1.9.9.826.1.26.109.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:UdldLinkPolicy:dn managed object property

cfprFabricUdldLinkPolicyRn

1.3.6.1.4.1.9.9.826.1.26.109.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldLinkPolicy:rn managed object property

cfprFabricUdldLinkPolicyAdminState

1.3.6.1.4.1.9.9.826.1.26.109.1.4

CfprFabricUdldLinkPolicyAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:UdldLinkPolicy:adminState managed object property

cfprFabricUdldLinkPolicyDescr

1.3.6.1.4.1.9.9.826.1.26.109.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldLinkPolicy:descr managed object property

cfprFabricUdldLinkPolicyIntId

1.3.6.1.4.1.9.9.826.1.26.109.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldLinkPolicy:intId managed object property

cfprFabricUdldLinkPolicyMode

1.3.6.1.4.1.9.9.826.1.26.109.1.7

CfprFabricUdldLinkPolicyMode0 = normal1 = aggressive · Integer32

Cisco Firepower fabric:UdldLinkPolicy:mode managed object property

cfprFabricUdldLinkPolicyName

1.3.6.1.4.1.9.9.826.1.26.109.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldLinkPolicy:name managed object property

cfprFabricUdldLinkPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.109.1.9

Gauge32

Cisco Firepower fabric:UdldLinkPolicy:policyLevel managed object property

cfprFabricUdldLinkPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.109.1.10

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:UdldLinkPolicy:policyOwner managed object property

cfprFabricUdldLinkPolicyProtocol

1.3.6.1.4.1.9.9.826.1.26.109.1.11

CfprFabricEthUdldPolicyProtocol0 = unknown1 = udld2 = cdp · Integer32

Cisco Firepower fabric:UdldLinkPolicy:protocol managed object property

cfprFabricUdldLinkPolicyType

1.3.6.1.4.1.9.9.826.1.26.109.1.12

CfprFabricEthLinkPolicyType · BITS

Cisco Firepower fabric:UdldLinkPolicy:type managed object property

cfprFabricUdldPolicyTable

1.3.6.1.4.1.9.9.826.1.26.110

Index: cfprFabricUdldPolicyInstanceId

Cisco Firepower fabric:UdldPolicy managed object table

cfprFabricUdldPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.26.110.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricUdldPolicyDn

1.3.6.1.4.1.9.9.826.1.26.110.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:UdldPolicy:dn managed object property

cfprFabricUdldPolicyRn

1.3.6.1.4.1.9.9.826.1.26.110.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldPolicy:rn managed object property

cfprFabricUdldPolicyDescr

1.3.6.1.4.1.9.9.826.1.26.110.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldPolicy:descr managed object property

cfprFabricUdldPolicyIntId

1.3.6.1.4.1.9.9.826.1.26.110.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldPolicy:intId managed object property

cfprFabricUdldPolicyMsgInterval

1.3.6.1.4.1.9.9.826.1.26.110.1.6

Gauge32

Cisco Firepower fabric:UdldPolicy:msgInterval managed object property

cfprFabricUdldPolicyName

1.3.6.1.4.1.9.9.826.1.26.110.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:UdldPolicy:name managed object property

cfprFabricUdldPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.26.110.1.8

Gauge32

Cisco Firepower fabric:UdldPolicy:policyLevel managed object property

cfprFabricUdldPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.110.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:UdldPolicy:policyOwner managed object property

cfprFabricUdldPolicyRecoveryAction

1.3.6.1.4.1.9.9.826.1.26.110.1.10

CfprFabricRecoveryAction0 = none1 = reset · Integer32

Cisco Firepower fabric:UdldPolicy:recoveryAction managed object property

cfprFabricVConTable

1.3.6.1.4.1.9.9.826.1.26.111

Index: cfprFabricVConInstanceId

Cisco Firepower fabric:VCon managed object table

cfprFabricVConInstanceId

1.3.6.1.4.1.9.9.826.1.26.111.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVConDn

1.3.6.1.4.1.9.9.826.1.26.111.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VCon:dn managed object property

cfprFabricVConRn

1.3.6.1.4.1.9.9.826.1.26.111.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VCon:rn managed object property

cfprFabricVConEquipmentDn

1.3.6.1.4.1.9.9.826.1.26.111.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VCon:equipmentDn managed object property

cfprFabricVConFabric

1.3.6.1.4.1.9.9.826.1.26.111.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VCon:fabric managed object property

cfprFabricVConId

1.3.6.1.4.1.9.9.826.1.26.111.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VCon:id managed object property

cfprFabricVConInstType

1.3.6.1.4.1.9.9.826.1.26.111.1.7

CfprFabricVConInstType1 = auto2 = manual3 = policy · Integer32

Cisco Firepower fabric:VCon:instType managed object property

cfprFabricVConPlacement

1.3.6.1.4.1.9.9.826.1.26.111.1.8

CfprFabricVConPlacementPref1 = physical2 = auto · Integer32

Cisco Firepower fabric:VCon:placement managed object property

cfprFabricVConSelect

1.3.6.1.4.1.9.9.826.1.26.111.1.9

CfprFabricVConSelectPref1 = assignedOnly2 = unassignedOnly4 = dynamicOnly7 = excludeUsnic8 = usnicOnly11 = excludeDynamic13 = excludeUnassigned15 = all · Integer32

Cisco Firepower fabric:VCon:select managed object property

cfprFabricVConShare

1.3.6.1.4.1.9.9.826.1.26.111.1.10

CfprFabricVConSharePref1 = exclusiveOnly2 = exclusivePreferred3 = sameTransport4 = differentTransport5 = shared · Integer32

Cisco Firepower fabric:VCon:share managed object property

cfprFabricVConTransport

1.3.6.1.4.1.9.9.826.1.26.111.1.11

CfprFabricVConTransportPref · BITS

Cisco Firepower fabric:VCon:transport managed object property

cfprFabricVConProfileTable

1.3.6.1.4.1.9.9.826.1.26.112

Index: cfprFabricVConProfileInstanceId

Cisco Firepower fabric:VConProfile managed object table

cfprFabricVConProfileInstanceId

1.3.6.1.4.1.9.9.826.1.26.112.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVConProfileDn

1.3.6.1.4.1.9.9.826.1.26.112.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VConProfile:dn managed object property

cfprFabricVConProfileRn

1.3.6.1.4.1.9.9.826.1.26.112.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VConProfile:rn managed object property

cfprFabricVConProfileDescr

1.3.6.1.4.1.9.9.826.1.26.112.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VConProfile:descr managed object property

cfprFabricVConProfileIntId

1.3.6.1.4.1.9.9.826.1.26.112.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VConProfile:intId managed object property

cfprFabricVConProfileMezzMapping

1.3.6.1.4.1.9.9.826.1.26.112.1.6

CfprFabricVConMappingScheme2 = roundRobin3 = linearOrdered4 = roundRobinToLinearOrdered5 = linearOrderedToRoundRobin · Integer32

Cisco Firepower fabric:VConProfile:mezzMapping managed object property

cfprFabricVConProfileName

1.3.6.1.4.1.9.9.826.1.26.112.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VConProfile:name managed object property

cfprFabricVConProfilePolicyLevel

1.3.6.1.4.1.9.9.826.1.26.112.1.8

Gauge32

Cisco Firepower fabric:VConProfile:policyLevel managed object property

cfprFabricVConProfilePolicyOwner

1.3.6.1.4.1.9.9.826.1.26.112.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:VConProfile:policyOwner managed object property

cfprFabricVlanTable

1.3.6.1.4.1.9.9.826.1.26.113

Index: cfprFabricVlanInstanceId

Cisco Firepower fabric:Vlan managed object table

cfprFabricVlanInstanceId

1.3.6.1.4.1.9.9.826.1.26.113.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVlanDn

1.3.6.1.4.1.9.9.826.1.26.113.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Vlan:dn managed object property

cfprFabricVlanRn

1.3.6.1.4.1.9.9.826.1.26.113.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:rn managed object property

cfprFabricVlanAssocPrimaryVlanState

1.3.6.1.4.1.9.9.826.1.26.113.1.4

CfprFabricVlanAssocPrimaryVlanState1 = ok2 = isEmpty3 = doesNotExists4 = isNotPrimaryType5 = isInErrorState · Integer32

Cisco Firepower fabric:Vlan:assocPrimaryVlanState managed object property

cfprFabricVlanAssocPrimaryVlanSwitchId

1.3.6.1.4.1.9.9.826.1.26.113.1.5

CfprFabricAVlanAssocPrimaryVlanSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:Vlan:assocPrimaryVlanSwitchId managed object property

cfprFabricVlanCloud

1.3.6.1.4.1.9.9.826.1.26.113.1.6

CfprFabricCloudType · BITS

Cisco Firepower fabric:Vlan:cloud managed object property

cfprFabricVlanCompressionType

1.3.6.1.4.1.9.9.826.1.26.113.1.7

CfprFabricVlanCompType1 = included2 = excluded · Integer32

Cisco Firepower fabric:Vlan:compressionType managed object property

cfprFabricVlanConfigIssues

1.3.6.1.4.1.9.9.826.1.26.113.1.8

CfprFabricVlanConfigIssues · BITS

Cisco Firepower fabric:Vlan:configIssues managed object property

cfprFabricVlanDefaultNet

1.3.6.1.4.1.9.9.826.1.26.113.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:Vlan:defaultNet managed object property

cfprFabricVlanEpDn

1.3.6.1.4.1.9.9.826.1.26.113.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:epDn managed object property

cfprFabricVlanFltAggr

1.3.6.1.4.1.9.9.826.1.26.113.1.11

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:Vlan:fltAggr managed object property

cfprFabricVlanGlobal

1.3.6.1.4.1.9.9.826.1.26.113.1.12

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:Vlan:global managed object property

cfprFabricVlanId

1.3.6.1.4.1.9.9.826.1.26.113.1.13

Gauge32

Cisco Firepower fabric:Vlan:id managed object property

cfprFabricVlanIfRole

1.3.6.1.4.1.9.9.826.1.26.113.1.14

CfprFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:Vlan:ifRole managed object property

cfprFabricVlanIfType

1.3.6.1.4.1.9.9.826.1.26.113.1.15

CfprNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:Vlan:ifType managed object property

cfprFabricVlanLocal

1.3.6.1.4.1.9.9.826.1.26.113.1.16

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:Vlan:local managed object property

cfprFabricVlanLocale

1.3.6.1.4.1.9.9.826.1.26.113.1.17

CfprFabricVnetEpLocale · BITS

Cisco Firepower fabric:Vlan:locale managed object property

cfprFabricVlanMcastPolicyName

1.3.6.1.4.1.9.9.826.1.26.113.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:mcastPolicyName managed object property

cfprFabricVlanName

1.3.6.1.4.1.9.9.826.1.26.113.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:name managed object property

cfprFabricVlanOperMcastPolicyName

1.3.6.1.4.1.9.9.826.1.26.113.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:operMcastPolicyName managed object property

cfprFabricVlanOperState

1.3.6.1.4.1.9.9.826.1.26.113.1.21

CfprFabricVlanOperState1 = ok2 = errorMisconfigured · Integer32

Cisco Firepower fabric:Vlan:operState managed object property

cfprFabricVlanOverlapStateForA

1.3.6.1.4.1.9.9.826.1.26.113.1.22

CfprFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower fabric:Vlan:overlapStateForA managed object property

cfprFabricVlanOverlapStateForB

1.3.6.1.4.1.9.9.826.1.26.113.1.23

CfprFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower fabric:Vlan:overlapStateForB managed object property

cfprFabricVlanPeerDn

1.3.6.1.4.1.9.9.826.1.26.113.1.24

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:peerDn managed object property

cfprFabricVlanPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.113.1.25

CfprFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:Vlan:policyOwner managed object property

cfprFabricVlanPubNwDn

1.3.6.1.4.1.9.9.826.1.26.113.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:pubNwDn managed object property

cfprFabricVlanPubNwId

1.3.6.1.4.1.9.9.826.1.26.113.1.27

Gauge32

Cisco Firepower fabric:Vlan:pubNwId managed object property

cfprFabricVlanPubNwName

1.3.6.1.4.1.9.9.826.1.26.113.1.28

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vlan:pubNwName managed object property

cfprFabricVlanSharing

1.3.6.1.4.1.9.9.826.1.26.113.1.29

CfprFabricAVlanSharing0 = none1 = primary2 = isolated3 = community · Integer32

Cisco Firepower fabric:Vlan:sharing managed object property

cfprFabricVlanSwitchId

1.3.6.1.4.1.9.9.826.1.26.113.1.30

CfprFabricVlanSwitchId0 = none1 = a2 = b3 = dual · Integer32

Cisco Firepower fabric:Vlan:switchId managed object property

cfprFabricVlanTransport

1.3.6.1.4.1.9.9.826.1.26.113.1.31

CfprFabricAVlanTransport · BITS

Cisco Firepower fabric:Vlan:transport managed object property

cfprFabricVlanType

1.3.6.1.4.1.9.9.826.1.26.113.1.32

CfprFabricAVlanType · BITS

Cisco Firepower fabric:Vlan:type managed object property

cfprFabricVlanEpTable

1.3.6.1.4.1.9.9.826.1.26.114

Index: cfprFabricVlanEpInstanceId

Cisco Firepower fabric:VlanEp managed object table

cfprFabricVlanEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.114.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVlanEpDnData

1.3.6.1.4.1.9.9.826.1.26.114.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VlanEp:dn managed object property

cfprFabricVlanEpRn

1.3.6.1.4.1.9.9.826.1.26.114.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanEp:rn managed object property

cfprFabricVlanEpAssocPrimaryVlanState

1.3.6.1.4.1.9.9.826.1.26.114.1.4

CfprFabricVlanAssocPrimaryVlanState1 = ok2 = isEmpty3 = doesNotExists4 = isNotPrimaryType5 = isInErrorState · Integer32

Cisco Firepower fabric:VlanEp:assocPrimaryVlanState managed object property

cfprFabricVlanEpAssocPrimaryVlanSwitchId

1.3.6.1.4.1.9.9.826.1.26.114.1.5

CfprFabricAVlanAssocPrimaryVlanSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:VlanEp:assocPrimaryVlanSwitchId managed object property

cfprFabricVlanEpEpDn

1.3.6.1.4.1.9.9.826.1.26.114.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanEp:epDn managed object property

cfprFabricVlanEpId

1.3.6.1.4.1.9.9.826.1.26.114.1.7

Gauge32

Cisco Firepower fabric:VlanEp:id managed object property

cfprFabricVlanEpIfRole

1.3.6.1.4.1.9.9.826.1.26.114.1.8

CfprFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:VlanEp:ifRole managed object property

cfprFabricVlanEpIfType

1.3.6.1.4.1.9.9.826.1.26.114.1.9

CfprNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:VlanEp:ifType managed object property

cfprFabricVlanEpIsNative

1.3.6.1.4.1.9.9.826.1.26.114.1.10

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:VlanEp:isNative managed object property

cfprFabricVlanEpLocale

1.3.6.1.4.1.9.9.826.1.26.114.1.11

CfprFabricVnetEpLocale · BITS

Cisco Firepower fabric:VlanEp:locale managed object property

cfprFabricVlanEpName

1.3.6.1.4.1.9.9.826.1.26.114.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanEp:name managed object property

cfprFabricVlanEpOperState

1.3.6.1.4.1.9.9.826.1.26.114.1.13

CfprFabricVlanOperState1 = ok2 = errorMisconfigured · Integer32

Cisco Firepower fabric:VlanEp:operState managed object property

cfprFabricVlanEpOverlapStateForA

1.3.6.1.4.1.9.9.826.1.26.114.1.14

CfprFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower fabric:VlanEp:overlapStateForA managed object property

cfprFabricVlanEpOverlapStateForB

1.3.6.1.4.1.9.9.826.1.26.114.1.15

CfprFabricVlanOverlapState0 = notActive1 = ok2 = sharingTypeMismatch3 = primaryIdMismatch · Integer32

Cisco Firepower fabric:VlanEp:overlapStateForB managed object property

cfprFabricVlanEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.114.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanEp:peerDn managed object property

cfprFabricVlanEpPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.114.1.17

CfprFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:VlanEp:policyOwner managed object property

cfprFabricVlanEpPubNwDn

1.3.6.1.4.1.9.9.826.1.26.114.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanEp:pubNwDn managed object property

cfprFabricVlanEpPubNwId

1.3.6.1.4.1.9.9.826.1.26.114.1.19

Gauge32

Cisco Firepower fabric:VlanEp:pubNwId managed object property

cfprFabricVlanEpPubNwName

1.3.6.1.4.1.9.9.826.1.26.114.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanEp:pubNwName managed object property

cfprFabricVlanEpSharing

1.3.6.1.4.1.9.9.826.1.26.114.1.21

CfprFabricAVlanSharing0 = none1 = primary2 = isolated3 = community · Integer32

Cisco Firepower fabric:VlanEp:sharing managed object property

cfprFabricVlanEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.114.1.22

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:VlanEp:switchId managed object property

cfprFabricVlanEpTransport

1.3.6.1.4.1.9.9.826.1.26.114.1.23

CfprFabricAVlanTransport · BITS

Cisco Firepower fabric:VlanEp:transport managed object property

cfprFabricVlanEpType

1.3.6.1.4.1.9.9.826.1.26.114.1.24

CfprFabricAVlanType · BITS

Cisco Firepower fabric:VlanEp:type managed object property

cfprFabricVlanGroupReqTable

1.3.6.1.4.1.9.9.826.1.26.115

Index: cfprFabricVlanGroupReqInstanceId

Cisco Firepower fabric:VlanGroupReq managed object table

cfprFabricVlanGroupReqInstanceId

1.3.6.1.4.1.9.9.826.1.26.115.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVlanGroupReqDn

1.3.6.1.4.1.9.9.826.1.26.115.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VlanGroupReq:dn managed object property

cfprFabricVlanGroupReqRn

1.3.6.1.4.1.9.9.826.1.26.115.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanGroupReq:rn managed object property

cfprFabricVlanGroupReqConfigIssues

1.3.6.1.4.1.9.9.826.1.26.115.1.4

CfprFabricReqIssues · BITS

Cisco Firepower fabric:VlanGroupReq:configIssues managed object property

cfprFabricVlanGroupReqName

1.3.6.1.4.1.9.9.826.1.26.115.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanGroupReq:name managed object property

cfprFabricVlanGroupReqType

1.3.6.1.4.1.9.9.826.1.26.115.1.6

CfprFabricAccessType0 = lan1 = san · Integer32

Cisco Firepower fabric:VlanGroupReq:type managed object property

cfprFabricVlanPermitTable

1.3.6.1.4.1.9.9.826.1.26.116

Index: cfprFabricVlanPermitInstanceId

Cisco Firepower fabric:VlanPermit managed object table

cfprFabricVlanPermitInstanceId

1.3.6.1.4.1.9.9.826.1.26.116.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVlanPermitDn

1.3.6.1.4.1.9.9.826.1.26.116.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VlanPermit:dn managed object property

cfprFabricVlanPermitRn

1.3.6.1.4.1.9.9.826.1.26.116.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanPermit:rn managed object property

cfprFabricVlanPermitCloud

1.3.6.1.4.1.9.9.826.1.26.116.1.4

CfprFabricCloudType · BITS

Cisco Firepower fabric:VlanPermit:cloud managed object property

cfprFabricVlanPermitName

1.3.6.1.4.1.9.9.826.1.26.116.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanPermit:name managed object property

cfprFabricVlanPermitSwitchId

1.3.6.1.4.1.9.9.826.1.26.116.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanPermit:switchId managed object property

cfprFabricVlanReqTable

1.3.6.1.4.1.9.9.826.1.26.117

Index: cfprFabricVlanReqInstanceId

Cisco Firepower fabric:VlanReq managed object table

cfprFabricVlanReqInstanceId

1.3.6.1.4.1.9.9.826.1.26.117.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVlanReqDn

1.3.6.1.4.1.9.9.826.1.26.117.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VlanReq:dn managed object property

cfprFabricVlanReqRn

1.3.6.1.4.1.9.9.826.1.26.117.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanReq:rn managed object property

cfprFabricVlanReqConfigIssues

1.3.6.1.4.1.9.9.826.1.26.117.1.4

CfprFabricReqIssues · BITS

Cisco Firepower fabric:VlanReq:configIssues managed object property

cfprFabricVlanReqName

1.3.6.1.4.1.9.9.826.1.26.117.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VlanReq:name managed object property

cfprFabricVlanReqType

1.3.6.1.4.1.9.9.826.1.26.117.1.6

CfprFabricAccessType0 = lan1 = san · Integer32

Cisco Firepower fabric:VlanReq:type managed object property

cfprFabricVnetEpSyncEpTable

1.3.6.1.4.1.9.9.826.1.26.118

Index: cfprFabricVnetEpSyncEpInstanceId

Cisco Firepower fabric:VnetEpSyncEp managed object table

cfprFabricVnetEpSyncEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.118.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVnetEpSyncEpDn

1.3.6.1.4.1.9.9.826.1.26.118.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VnetEpSyncEp:dn managed object property

cfprFabricVnetEpSyncEpRn

1.3.6.1.4.1.9.9.826.1.26.118.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEp:rn managed object property

cfprFabricVnetEpSyncEpFsmDescr

1.3.6.1.4.1.9.9.826.1.26.118.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEp:fsmDescr managed object property

cfprFabricVnetEpSyncEpFsmPrev

1.3.6.1.4.1.9.9.826.1.26.118.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEp:fsmPrev managed object property

cfprFabricVnetEpSyncEpFsmProgr

1.3.6.1.4.1.9.9.826.1.26.118.1.6

Gauge32

Cisco Firepower fabric:VnetEpSyncEp:fsmProgr managed object property

cfprFabricVnetEpSyncEpFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.26.118.1.7

Gauge32

Cisco Firepower fabric:VnetEpSyncEp:fsmRmtInvErrCode managed object property

cfprFabricVnetEpSyncEpFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.26.118.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEp:fsmRmtInvErrDescr managed object property

cfprFabricVnetEpSyncEpFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.26.118.1.9

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:VnetEpSyncEp:fsmRmtInvRslt managed object property

cfprFabricVnetEpSyncEpFsmStageDescr

1.3.6.1.4.1.9.9.826.1.26.118.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEp:fsmStageDescr managed object property

cfprFabricVnetEpSyncEpFsmStamp

1.3.6.1.4.1.9.9.826.1.26.118.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:VnetEpSyncEp:fsmStamp managed object property

cfprFabricVnetEpSyncEpFsmStatus

1.3.6.1.4.1.9.9.826.1.26.118.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEp:fsmStatus managed object property

cfprFabricVnetEpSyncEpFsmTry

1.3.6.1.4.1.9.9.826.1.26.118.1.13

Gauge32

Cisco Firepower fabric:VnetEpSyncEp:fsmTry managed object property

cfprFabricVnetEpSyncEpGenNumSync

1.3.6.1.4.1.9.9.826.1.26.118.1.14

Gauge32

Cisco Firepower fabric:VnetEpSyncEp:genNumSync managed object property

cfprFabricVnetEpSyncEpId

1.3.6.1.4.1.9.9.826.1.26.118.1.15

Gauge32

Cisco Firepower fabric:VnetEpSyncEp:id managed object property

cfprFabricVnetEpSyncEpIsChangedObjectUpdate

1.3.6.1.4.1.9.9.826.1.26.118.1.16

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:VnetEpSyncEp:isChangedObjectUpdate managed object property

cfprFabricVnetEpSyncEpFsmTable

1.3.6.1.4.1.9.9.826.1.26.119

Index: cfprFabricVnetEpSyncEpFsmInstanceId

Cisco Firepower fabric:VnetEpSyncEpFsm managed object table

cfprFabricVnetEpSyncEpFsmInstanceId

1.3.6.1.4.1.9.9.826.1.26.119.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVnetEpSyncEpFsmDn

1.3.6.1.4.1.9.9.826.1.26.119.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VnetEpSyncEpFsm:dn managed object property

cfprFabricVnetEpSyncEpFsmRn

1.3.6.1.4.1.9.9.826.1.26.119.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEpFsm:rn managed object property

cfprFabricVnetEpSyncEpFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.26.119.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:VnetEpSyncEpFsm:completionTime managed object property

cfprFabricVnetEpSyncEpFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.26.119.1.5

CfprFabricVnetEpSyncEpFsmCurrentFsm0 = nop1481 = pushVnetEpDeletion · Integer32

Cisco Firepower fabric:VnetEpSyncEpFsm:currentFsm managed object property

cfprFabricVnetEpSyncEpFsmDescrData

1.3.6.1.4.1.9.9.826.1.26.119.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEpFsm:descr managed object property

cfprFabricVnetEpSyncEpFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.26.119.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:VnetEpSyncEpFsm:fsmStatus managed object property

cfprFabricVnetEpSyncEpFsmProgress

1.3.6.1.4.1.9.9.826.1.26.119.1.8

Gauge32

Cisco Firepower fabric:VnetEpSyncEpFsm:progress managed object property

cfprFabricVnetEpSyncEpFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.26.119.1.9

Gauge32

Cisco Firepower fabric:VnetEpSyncEpFsm:rmtErrCode managed object property

cfprFabricVnetEpSyncEpFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.26.119.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEpFsm:rmtErrDescr managed object property

cfprFabricVnetEpSyncEpFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.26.119.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower fabric:VnetEpSyncEpFsm:rmtRslt managed object property

cfprFabricVnetEpSyncEpFsmStageTable

1.3.6.1.4.1.9.9.826.1.26.120

Index: cfprFabricVnetEpSyncEpFsmStageInstanceId

Cisco Firepower fabric:VnetEpSyncEpFsmStage managed object table

cfprFabricVnetEpSyncEpFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.26.120.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVnetEpSyncEpFsmStageDn

1.3.6.1.4.1.9.9.826.1.26.120.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VnetEpSyncEpFsmStage:dn managed object property

cfprFabricVnetEpSyncEpFsmStageRn

1.3.6.1.4.1.9.9.826.1.26.120.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEpFsmStage:rn managed object property

cfprFabricVnetEpSyncEpFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.26.120.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEpFsmStage:descr managed object property

cfprFabricVnetEpSyncEpFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.26.120.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower fabric:VnetEpSyncEpFsmStage:lastUpdateTime managed object property

cfprFabricVnetEpSyncEpFsmStageName

1.3.6.1.4.1.9.9.826.1.26.120.1.6

CfprFabricVnetEpSyncEpFsmStageName0 = nop1481 = pushVnetEpDeletionBegin1482 = pushVnetEpDeletionSync1485 = pushVnetEpDeletionFail1486 = pushVnetEpDeletionSuccess · Integer32

Cisco Firepower fabric:VnetEpSyncEpFsmStage:name managed object property

cfprFabricVnetEpSyncEpFsmStageOrder

1.3.6.1.4.1.9.9.826.1.26.120.1.7

Gauge32

Cisco Firepower fabric:VnetEpSyncEpFsmStage:order managed object property

cfprFabricVnetEpSyncEpFsmStageRetry

1.3.6.1.4.1.9.9.826.1.26.120.1.8

Gauge32

Cisco Firepower fabric:VnetEpSyncEpFsmStage:retry managed object property

cfprFabricVnetEpSyncEpFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.26.120.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower fabric:VnetEpSyncEpFsmStage:stageStatus managed object property

cfprFabricVnetEpSyncEpFsmTaskTable

1.3.6.1.4.1.9.9.826.1.26.121

Index: cfprFabricVnetEpSyncEpFsmTaskInstanceId

Cisco Firepower fabric:VnetEpSyncEpFsmTask managed object table

cfprFabricVnetEpSyncEpFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.26.121.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVnetEpSyncEpFsmTaskDn

1.3.6.1.4.1.9.9.826.1.26.121.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VnetEpSyncEpFsmTask:dn managed object property

cfprFabricVnetEpSyncEpFsmTaskRn

1.3.6.1.4.1.9.9.826.1.26.121.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VnetEpSyncEpFsmTask:rn managed object property

cfprFabricVnetEpSyncEpFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.26.121.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower fabric:VnetEpSyncEpFsmTask:completion managed object property

cfprFabricVnetEpSyncEpFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.26.121.1.5

CfprFsmFlags · BITS

Cisco Firepower fabric:VnetEpSyncEpFsmTask:flags managed object property

cfprFabricVnetEpSyncEpFsmTaskItem

1.3.6.1.4.1.9.9.826.1.26.121.1.6

CfprFabricVnetEpSyncEpFsmTaskItem0 = nop1481 = pushVnetEpDeletion · Integer32

Cisco Firepower fabric:VnetEpSyncEpFsmTask:item managed object property

cfprFabricVnetEpSyncEpFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.26.121.1.7

Gauge32

Cisco Firepower fabric:VnetEpSyncEpFsmTask:seqId managed object property

cfprFabricVsanTable

1.3.6.1.4.1.9.9.826.1.26.122

Index: cfprFabricVsanInstanceId

Cisco Firepower fabric:Vsan managed object table

cfprFabricVsanInstanceId

1.3.6.1.4.1.9.9.826.1.26.122.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVsanDn

1.3.6.1.4.1.9.9.826.1.26.122.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:Vsan:dn managed object property

cfprFabricVsanRn

1.3.6.1.4.1.9.9.826.1.26.122.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vsan:rn managed object property

cfprFabricVsanDefaultZoning

1.3.6.1.4.1.9.9.826.1.26.122.1.4

CfprFabricDefaultZoningState0 = disabled1 = enabled · Integer32

Cisco Firepower fabric:Vsan:defaultZoning managed object property

cfprFabricVsanEpDn

1.3.6.1.4.1.9.9.826.1.26.122.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vsan:epDn managed object property

cfprFabricVsanFcZoneSharingMode

1.3.6.1.4.1.9.9.826.1.26.122.1.6

CfprFabricFcZoneSharingMode0 = coalesce1 = clearUnmanagedZoneAll · Integer32

Cisco Firepower fabric:Vsan:fcZoneSharingMode managed object property

cfprFabricVsanFcoeVlan

1.3.6.1.4.1.9.9.826.1.26.122.1.7

Gauge32

Cisco Firepower fabric:Vsan:fcoeVlan managed object property

cfprFabricVsanFltAggr

1.3.6.1.4.1.9.9.826.1.26.122.1.8

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:Vsan:fltAggr managed object property

cfprFabricVsanGlobal

1.3.6.1.4.1.9.9.826.1.26.122.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:Vsan:global managed object property

cfprFabricVsanId

1.3.6.1.4.1.9.9.826.1.26.122.1.10

Gauge32

Cisco Firepower fabric:Vsan:id managed object property

cfprFabricVsanIfRole

1.3.6.1.4.1.9.9.826.1.26.122.1.11

CfprFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:Vsan:ifRole managed object property

cfprFabricVsanIfType

1.3.6.1.4.1.9.9.826.1.26.122.1.12

CfprNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:Vsan:ifType managed object property

cfprFabricVsanLocal

1.3.6.1.4.1.9.9.826.1.26.122.1.13

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:Vsan:local managed object property

cfprFabricVsanLocale

1.3.6.1.4.1.9.9.826.1.26.122.1.14

CfprFabricVnetEpLocale · BITS

Cisco Firepower fabric:Vsan:locale managed object property

cfprFabricVsanName

1.3.6.1.4.1.9.9.826.1.26.122.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vsan:name managed object property

cfprFabricVsanOperState

1.3.6.1.4.1.9.9.826.1.26.122.1.16

CfprFabricVsanOperState1 = ok2 = errorMisconfigured3 = errorReserved · Integer32

Cisco Firepower fabric:Vsan:operState managed object property

cfprFabricVsanPeerDn

1.3.6.1.4.1.9.9.826.1.26.122.1.17

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:Vsan:peerDn managed object property

cfprFabricVsanPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.122.1.18

CfprFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:Vsan:policyOwner managed object property

cfprFabricVsanSwitchId

1.3.6.1.4.1.9.9.826.1.26.122.1.19

CfprFabricVsanSwitchId0 = none1 = a2 = b3 = dual · Integer32

Cisco Firepower fabric:Vsan:switchId managed object property

cfprFabricVsanTransport

1.3.6.1.4.1.9.9.826.1.26.122.1.20

CfprFabricAVsanTransport · BITS

Cisco Firepower fabric:Vsan:transport managed object property

cfprFabricVsanType

1.3.6.1.4.1.9.9.826.1.26.122.1.21

CfprFabricAVsanType · BITS

Cisco Firepower fabric:Vsan:type managed object property

cfprFabricVsanZoningState

1.3.6.1.4.1.9.9.826.1.26.122.1.22

CfprFabricZoningState0 = disabled1 = enabled · Integer32

Cisco Firepower fabric:Vsan:zoningState managed object property

cfprFabricVsanEpTable

1.3.6.1.4.1.9.9.826.1.26.123

Index: cfprFabricVsanEpInstanceId

Cisco Firepower fabric:VsanEp managed object table

cfprFabricVsanEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.123.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVsanEpDnData

1.3.6.1.4.1.9.9.826.1.26.123.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VsanEp:dn managed object property

cfprFabricVsanEpRn

1.3.6.1.4.1.9.9.826.1.26.123.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VsanEp:rn managed object property

cfprFabricVsanEpEpDn

1.3.6.1.4.1.9.9.826.1.26.123.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VsanEp:epDn managed object property

cfprFabricVsanEpFcoeVlan

1.3.6.1.4.1.9.9.826.1.26.123.1.5

Gauge32

Cisco Firepower fabric:VsanEp:fcoeVlan managed object property

cfprFabricVsanEpId

1.3.6.1.4.1.9.9.826.1.26.123.1.6

Gauge32

Cisco Firepower fabric:VsanEp:id managed object property

cfprFabricVsanEpIfRole

1.3.6.1.4.1.9.9.826.1.26.123.1.7

CfprFabricVnetEpIfRole0 = unknown1 = network2 = server3 = mgmt4 = diag5 = storage6 = monitor7 = fcoeStorage8 = nasStorage9 = fcoeNasStorage10 = fcoeUplink11 = networkFcoeUplink12 = service · Integer32

Cisco Firepower fabric:VsanEp:ifRole managed object property

cfprFabricVsanEpIfType

1.3.6.1.4.1.9.9.826.1.26.123.1.8

CfprNetworkVnetEpIfType0 = unknown1 = physical2 = aggregation3 = virtual · Integer32

Cisco Firepower fabric:VsanEp:ifType managed object property

cfprFabricVsanEpLocale

1.3.6.1.4.1.9.9.826.1.26.123.1.9

CfprFabricVnetEpLocale · BITS

Cisco Firepower fabric:VsanEp:locale managed object property

cfprFabricVsanEpName

1.3.6.1.4.1.9.9.826.1.26.123.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VsanEp:name managed object property

cfprFabricVsanEpOperState

1.3.6.1.4.1.9.9.826.1.26.123.1.11

CfprFabricVsanOperState1 = ok2 = errorMisconfigured3 = errorReserved · Integer32

Cisco Firepower fabric:VsanEp:operState managed object property

cfprFabricVsanEpPeerDn

1.3.6.1.4.1.9.9.826.1.26.123.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VsanEp:peerDn managed object property

cfprFabricVsanEpPolicyOwner

1.3.6.1.4.1.9.9.826.1.26.123.1.13

CfprFabricVnetEpPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower fabric:VsanEp:policyOwner managed object property

cfprFabricVsanEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.123.1.14

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:VsanEp:switchId managed object property

cfprFabricVsanEpTransport

1.3.6.1.4.1.9.9.826.1.26.123.1.15

CfprFabricAVsanTransport · BITS

Cisco Firepower fabric:VsanEp:transport managed object property

cfprFabricVsanEpType

1.3.6.1.4.1.9.9.826.1.26.123.1.16

CfprFabricAVsanType · BITS

Cisco Firepower fabric:VsanEp:type managed object property

cfprFabricVsanEpZoningState

1.3.6.1.4.1.9.9.826.1.26.123.1.17

CfprFabricZoningState0 = disabled1 = enabled · Integer32

Cisco Firepower fabric:VsanEp:zoningState managed object property

cfprFabricVsanMembershipTable

1.3.6.1.4.1.9.9.826.1.26.124

Index: cfprFabricVsanMembershipInstanceId

Cisco Firepower fabric:VsanMembership managed object table

cfprFabricVsanMembershipInstanceId

1.3.6.1.4.1.9.9.826.1.26.124.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricVsanMembershipDn

1.3.6.1.4.1.9.9.826.1.26.124.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:VsanMembership:dn managed object property

cfprFabricVsanMembershipRn

1.3.6.1.4.1.9.9.826.1.26.124.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VsanMembership:rn managed object property

cfprFabricVsanMembershipMemberStatus

1.3.6.1.4.1.9.9.826.1.26.124.1.4

CfprFabricMemberStatus0 = up1 = down · Integer32

Cisco Firepower fabric:VsanMembership:memberStatus managed object property

cfprFabricVsanMembershipParentAdminState

1.3.6.1.4.1.9.9.826.1.26.124.1.5

CfprFabricAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:VsanMembership:parentAdminState managed object property

cfprFabricVsanMembershipStateQual

1.3.6.1.4.1.9.9.826.1.26.124.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:VsanMembership:stateQual managed object property

cfprFabricVsanMembershipVsanId

1.3.6.1.4.1.9.9.826.1.26.124.1.7

Gauge32

Cisco Firepower fabric:VsanMembership:vsanId managed object property

cfprFabricZoneIdUniverseTable

1.3.6.1.4.1.9.9.826.1.26.125

Index: cfprFabricZoneIdUniverseInstanceId

Cisco Firepower fabric:ZoneIdUniverse managed object table

cfprFabricZoneIdUniverseInstanceId

1.3.6.1.4.1.9.9.826.1.26.125.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricZoneIdUniverseDn

1.3.6.1.4.1.9.9.826.1.26.125.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:ZoneIdUniverse:dn managed object property

cfprFabricZoneIdUniverseRn

1.3.6.1.4.1.9.9.826.1.26.125.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:ZoneIdUniverse:rn managed object property

cfprFabricSspEthMonTable

1.3.6.1.4.1.9.9.826.1.26.126

Index: cfprFabricSspEthMonInstanceId

Cisco Firepower fabric:SspEthMon managed object table

cfprFabricSspEthMonInstanceId

1.3.6.1.4.1.9.9.826.1.26.126.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspEthMonDn

1.3.6.1.4.1.9.9.826.1.26.126.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspEthMon:dn managed object property

cfprFabricSspEthMonRn

1.3.6.1.4.1.9.9.826.1.26.126.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMon:rn managed object property

cfprFabricSspEthMonAdminState

1.3.6.1.4.1.9.9.826.1.26.126.1.4

CfprFabricSspMonAdminState1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:SspEthMon:adminState managed object property

cfprFabricSspEthMonAppendFlag

1.3.6.1.4.1.9.9.826.1.26.126.1.5

CfprFabricSspEthMonAppendFlag1 = append2 = overwrite · Integer32

Cisco Firepower fabric:SspEthMon:appendFlag managed object property

cfprFabricSspEthMonConfigFailReason

1.3.6.1.4.1.9.9.826.1.26.126.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMon:configFailReason managed object property

cfprFabricSspEthMonDelPcap

1.3.6.1.4.1.9.9.826.1.26.126.1.7

CfprFabricSspMonDelPcap1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:SspEthMon:delPcap managed object property

cfprFabricSspEthMonId

1.3.6.1.4.1.9.9.826.1.26.126.1.8

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SspEthMon:id managed object property

cfprFabricSspEthMonIsConfigSuccess

1.3.6.1.4.1.9.9.826.1.26.126.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:SspEthMon:isConfigSuccess managed object property

cfprFabricSspEthMonName

1.3.6.1.4.1.9.9.826.1.26.126.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMon:name managed object property

cfprFabricSspEthMonOperState

1.3.6.1.4.1.9.9.826.1.26.126.1.11

CfprFabricSspMonOperState0 = unknown1 = up2 = down3 = error · Integer32

Cisco Firepower fabric:SspEthMon:operState managed object property

cfprFabricSspEthMonOperStateReason

1.3.6.1.4.1.9.9.826.1.26.126.1.12

CfprFabricSspMonOperStateReason0 = active1 = noHardwareResource2 = noOperationalSrcDst3 = genericError4 = noSourcesConfigured5 = sessionAdminShut8 = directoryError12 = unknown16 = fileError32 = memoryOvershoot64 = pipeError128 = linkError256 = filterError768 = filterErrorAppId · Integer32

Cisco Firepower fabric:SspEthMon:operStateReason managed object property

cfprFabricSspEthMonPeerDn

1.3.6.1.4.1.9.9.826.1.26.126.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMon:peerDn managed object property

cfprFabricSspEthMonSession

1.3.6.1.4.1.9.9.826.1.26.126.1.14

Gauge32

Cisco Firepower fabric:SspEthMon:session managed object property

cfprFabricSspEthMonSessionMemUsage

1.3.6.1.4.1.9.9.826.1.26.126.1.15

Gauge32

Cisco Firepower fabric:SspEthMon:sessionMemUsage managed object property

cfprFabricSspEthMonSourceConfigured

1.3.6.1.4.1.9.9.826.1.26.126.1.16

Gauge32

Cisco Firepower fabric:SspEthMon:sourceConfigured managed object property

cfprFabricSspEthMonDelAllSessEnabledState

1.3.6.1.4.1.9.9.826.1.26.126.1.17

CfprFabricSspEthMonDelAllSessEnabledState1 = valid2 = invalid · Integer32

Cisco Firepower fabric:SspEthMon:delAllSessEnabledState managed object property

cfprFabricSspEthMonDropCount

1.3.6.1.4.1.9.9.826.1.26.126.1.18

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:SspEthMon:dropCount managed object property

cfprFabricSspEthMonErrorCode

1.3.6.1.4.1.9.9.826.1.26.126.1.19

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMon:errorCode managed object property

cfprFabricSspEthMonIsConfiguredByAG

1.3.6.1.4.1.9.9.826.1.26.126.1.20

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:SspEthMon:isConfiguredByAG managed object property

cfprFabricSspEthMonReBoot

1.3.6.1.4.1.9.9.826.1.26.126.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMon:reBoot managed object property

cfprFabricSspEthMonSessionPcapSnapLen

1.3.6.1.4.1.9.9.826.1.26.126.1.22

Gauge32

Cisco Firepower fabric:SspEthMon:sessionPcapSnapLen managed object property

cfprFabricSspEthMonFilterEpTable

1.3.6.1.4.1.9.9.826.1.26.127

Index: cfprFabricSspEthMonFilterEpInstanceId

Cisco Firepower fabric:SspEthMonFilterEp managed object table

cfprFabricSspEthMonFilterEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.127.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspEthMonFilterEpDn

1.3.6.1.4.1.9.9.826.1.26.127.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspEthMonFilterEp:dn managed object property

cfprFabricSspEthMonFilterEpRn

1.3.6.1.4.1.9.9.826.1.26.127.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonFilterEp:rn managed object property

cfprFabricSspEthMonFilterEpDestIp

1.3.6.1.4.1.9.9.826.1.26.127.1.4

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower fabric:SspEthMonFilterEp:destIp managed object property

cfprFabricSspEthMonFilterEpDestMAC

1.3.6.1.4.1.9.9.826.1.26.127.1.5

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower fabric:SspEthMonFilterEp:destMAC managed object property

cfprFabricSspEthMonFilterEpDestPort

1.3.6.1.4.1.9.9.826.1.26.127.1.6

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:destPort managed object property

cfprFabricSspEthMonFilterEpEthertype

1.3.6.1.4.1.9.9.826.1.26.127.1.7

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:ethertype managed object property

cfprFabricSspEthMonFilterEpIvlan

1.3.6.1.4.1.9.9.826.1.26.127.1.8

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:ivlan managed object property

cfprFabricSspEthMonFilterEpNameId

1.3.6.1.4.1.9.9.826.1.26.127.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonFilterEp:nameId managed object property

cfprFabricSspEthMonFilterEpOvlan

1.3.6.1.4.1.9.9.826.1.26.127.1.10

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:ovlan managed object property

cfprFabricSspEthMonFilterEpProtocol

1.3.6.1.4.1.9.9.826.1.26.127.1.11

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:protocol managed object property

cfprFabricSspEthMonFilterEpSrcIp

1.3.6.1.4.1.9.9.826.1.26.127.1.12

InetAddressIPv4Represents an IPv4 network address: Octets Contents Encoding 1-4 IPv4 address network-byte order The corresponding InetAddressType value is ipv4(1). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (4) · OCTET STRING · hint 1d.1d.1d.1d

Cisco Firepower fabric:SspEthMonFilterEp:srcIp managed object property

cfprFabricSspEthMonFilterEpSrcMAC

1.3.6.1.4.1.9.9.826.1.26.127.1.13

MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:

Cisco Firepower fabric:SspEthMonFilterEp:srcMAC managed object property

cfprFabricSspEthMonFilterEpSrcPort

1.3.6.1.4.1.9.9.826.1.26.127.1.14

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:srcPort managed object property

cfprFabricSspEthMonFilterEpDestIpv6

1.3.6.1.4.1.9.9.826.1.26.127.1.15

InetAddressIPv6Represents an IPv6 network address: Octets Contents Encoding 1-16 IPv6 address network-byte order The corresponding InetAddressType value is ipv6(2). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (16) · OCTET STRING · hint 2x:2x:2x:2x:2x:2x:2x:2x

Cisco Firepower fabric:SspEthMonFilterEp:destIpv6 managed object property

cfprFabricSspEthMonFilterEpEcmpId

1.3.6.1.4.1.9.9.826.1.26.127.1.16

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:ecmpId managed object property

cfprFabricSspEthMonFilterEpSrcIpv6

1.3.6.1.4.1.9.9.826.1.26.127.1.17

InetAddressIPv6Represents an IPv6 network address: Octets Contents Encoding 1-16 IPv6 address network-byte order The corresponding InetAddressType value is ipv6(2). This textual convention SHOULD NOT be used directly in object definitions, as it restricts addresses to a specific format. However, if it is used, it MAY be used either on its own or in conjunction with InetAddressType, as a pair. SIZE (16) · OCTET STRING · hint 2x:2x:2x:2x:2x:2x:2x:2x

Cisco Firepower fabric:SspEthMonFilterEp:srcIpv6 managed object property

cfprFabricSspEthMonFilterEpSubvlan

1.3.6.1.4.1.9.9.826.1.26.127.1.18

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:subvlan managed object property

cfprFabricSspEthMonFilterEpVifId

1.3.6.1.4.1.9.9.826.1.26.127.1.19

Gauge32

Cisco Firepower fabric:SspEthMonFilterEp:vifId managed object property

cfprFabricSspEthMonSrcAppEpTable

1.3.6.1.4.1.9.9.826.1.26.128

Index: cfprFabricSspEthMonSrcAppEpInstanceId

Cisco Firepower fabric:SspEthMonSrcAppEp managed object table

cfprFabricSspEthMonSrcAppEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.128.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspEthMonSrcAppEpDn

1.3.6.1.4.1.9.9.826.1.26.128.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspEthMonSrcAppEp:dn managed object property

cfprFabricSspEthMonSrcAppEpRn

1.3.6.1.4.1.9.9.826.1.26.128.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:rn managed object property

cfprFabricSspEthMonSrcAppEpAppName

1.3.6.1.4.1.9.9.826.1.26.128.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:appName managed object property

cfprFabricSspEthMonSrcAppEpFilter

1.3.6.1.4.1.9.9.826.1.26.128.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:filter managed object property

cfprFabricSspEthMonSrcAppEpLinkName

1.3.6.1.4.1.9.9.826.1.26.128.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:linkName managed object property

cfprFabricSspEthMonSrcAppEpPcapfile

1.3.6.1.4.1.9.9.826.1.26.128.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:pcapfile managed object property

cfprFabricSspEthMonSrcAppEpPcapfilename

1.3.6.1.4.1.9.9.826.1.26.128.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:pcapfilename managed object property

cfprFabricSspEthMonSrcAppEpPcapsize

1.3.6.1.4.1.9.9.826.1.26.128.1.9

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppEp:pcapsize managed object property

cfprFabricSspEthMonSrcAppEpPortName

1.3.6.1.4.1.9.9.826.1.26.128.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:portName managed object property

cfprFabricSspEthMonSrcAppEpSlotId

1.3.6.1.4.1.9.9.826.1.26.128.1.11

CfprFabricPktCaptureAppSlotId (1..3) · Gauge32

Cisco Firepower fabric:SspEthMonSrcAppEp:slotId managed object property

cfprFabricSspEthMonSrcAppEpAppInstance

1.3.6.1.4.1.9.9.826.1.26.128.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:appInstance managed object property

cfprFabricSspEthMonSrcAppEpSubInterface

1.3.6.1.4.1.9.9.826.1.26.128.1.13

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppEp:subInterface managed object property

cfprFabricSspEthMonSrcAppEpExternalLduLinkDn

1.3.6.1.4.1.9.9.826.1.26.128.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppEp:externalLduLinkDn managed object property

cfprFabricSspEthMonSrcAppLinksEpTable

1.3.6.1.4.1.9.9.826.1.26.129

Index: cfprFabricSspEthMonSrcAppLinksEpInstanceId

Cisco Firepower fabric:SspEthMonSrcAppLinksEp managed object table

cfprFabricSspEthMonSrcAppLinksEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.129.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspEthMonSrcAppLinksEpDn

1.3.6.1.4.1.9.9.826.1.26.129.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:dn managed object property

cfprFabricSspEthMonSrcAppLinksEpRn

1.3.6.1.4.1.9.9.826.1.26.129.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:rn managed object property

cfprFabricSspEthMonSrcAppLinksEpChassisId

1.3.6.1.4.1.9.9.826.1.26.129.1.4

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:chassisId managed object property

cfprFabricSspEthMonSrcAppLinksEpEqAggrPortId

1.3.6.1.4.1.9.9.826.1.26.129.1.5

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:eqAggrPortId managed object property

cfprFabricSspEthMonSrcAppLinksEpEqPortId

1.3.6.1.4.1.9.9.826.1.26.129.1.6

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:eqPortId managed object property

cfprFabricSspEthMonSrcAppLinksEpEqSlotId

1.3.6.1.4.1.9.9.826.1.26.129.1.7

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:eqSlotId managed object property

cfprFabricSspEthMonSrcAppLinksEpFilter

1.3.6.1.4.1.9.9.826.1.26.129.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:filter managed object property

cfprFabricSspEthMonSrcAppLinksEpFilterDn

1.3.6.1.4.1.9.9.826.1.26.129.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:filterDn managed object property

cfprFabricSspEthMonSrcAppLinksEpLifeCycle

1.3.6.1.4.1.9.9.826.1.26.129.1.10

CfprSwPktCaptureLifeCycle1 = normal2 = new3 = deleted · Integer32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:lifeCycle managed object property

cfprFabricSspEthMonSrcAppLinksEpName

1.3.6.1.4.1.9.9.826.1.26.129.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:name managed object property

cfprFabricSspEthMonSrcAppLinksEpPcapfile

1.3.6.1.4.1.9.9.826.1.26.129.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:pcapfile managed object property

cfprFabricSspEthMonSrcAppLinksEpPcapfilename

1.3.6.1.4.1.9.9.826.1.26.129.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:pcapfilename managed object property

cfprFabricSspEthMonSrcAppLinksEpPcapsize

1.3.6.1.4.1.9.9.826.1.26.129.1.14

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:pcapsize managed object property

cfprFabricSspEthMonSrcAppLinksEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.129.1.15

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:switchId managed object property

cfprFabricSspEthMonSrcAppLinksEpVlan

1.3.6.1.4.1.9.9.826.1.26.129.1.16

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:vlan managed object property

cfprFabricSspEthMonSrcAppLinksEpVifId

1.3.6.1.4.1.9.9.826.1.26.129.1.17

Gauge32

Cisco Firepower fabric:SspEthMonSrcAppLinksEp:vifId managed object property

cfprFabricSspEthMonSrcPhyAggrEpTable

1.3.6.1.4.1.9.9.826.1.26.130

Index: cfprFabricSspEthMonSrcPhyAggrEpInstanceId

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp managed object table

cfprFabricSspEthMonSrcPhyAggrEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.130.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspEthMonSrcPhyAggrEpDn

1.3.6.1.4.1.9.9.826.1.26.130.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:dn managed object property

cfprFabricSspEthMonSrcPhyAggrEpRn

1.3.6.1.4.1.9.9.826.1.26.130.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:rn managed object property

cfprFabricSspEthMonSrcPhyAggrEpAggrPortId

1.3.6.1.4.1.9.9.826.1.26.130.1.4

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:aggrPortId managed object property

cfprFabricSspEthMonSrcPhyAggrEpBreakoutPortId

1.3.6.1.4.1.9.9.826.1.26.130.1.5

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:breakoutPortId managed object property

cfprFabricSspEthMonSrcPhyAggrEpChassisId

1.3.6.1.4.1.9.9.826.1.26.130.1.6

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:chassisId managed object property

cfprFabricSspEthMonSrcPhyAggrEpFilter

1.3.6.1.4.1.9.9.826.1.26.130.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:filter managed object property

cfprFabricSspEthMonSrcPhyAggrEpPcapfile

1.3.6.1.4.1.9.9.826.1.26.130.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:pcapfile managed object property

cfprFabricSspEthMonSrcPhyAggrEpPcapfilename

1.3.6.1.4.1.9.9.826.1.26.130.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:pcapfilename managed object property

cfprFabricSspEthMonSrcPhyAggrEpPcapsize

1.3.6.1.4.1.9.9.826.1.26.130.1.10

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:pcapsize managed object property

cfprFabricSspEthMonSrcPhyAggrEpSlotId

1.3.6.1.4.1.9.9.826.1.26.130.1.11

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:slotId managed object property

cfprFabricSspEthMonSrcPhyAggrEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.130.1.12

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:switchId managed object property

cfprFabricSspEthMonSrcPhyAggrEpAppInstance

1.3.6.1.4.1.9.9.826.1.26.130.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:appInstance managed object property

cfprFabricSspEthMonSrcPhyAggrEpAppName

1.3.6.1.4.1.9.9.826.1.26.130.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:appName managed object property

cfprFabricSspEthMonSrcPhyAggrEpSubInterface

1.3.6.1.4.1.9.9.826.1.26.130.1.15

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:subInterface managed object property

cfprFabricSspEthMonSrcPhyAggrEpEcmpId

1.3.6.1.4.1.9.9.826.1.26.130.1.16

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyAggrEp:ecmpId managed object property

cfprFabricSspEthMonSrcPhyEpTable

1.3.6.1.4.1.9.9.826.1.26.131

Index: cfprFabricSspEthMonSrcPhyEpInstanceId

Cisco Firepower fabric:SspEthMonSrcPhyEp managed object table

cfprFabricSspEthMonSrcPhyEpInstanceId

1.3.6.1.4.1.9.9.826.1.26.131.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspEthMonSrcPhyEpDn

1.3.6.1.4.1.9.9.826.1.26.131.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspEthMonSrcPhyEp:dn managed object property

cfprFabricSspEthMonSrcPhyEpRn

1.3.6.1.4.1.9.9.826.1.26.131.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyEp:rn managed object property

cfprFabricSspEthMonSrcPhyEpChassisId

1.3.6.1.4.1.9.9.826.1.26.131.1.4

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyEp:chassisId managed object property

cfprFabricSspEthMonSrcPhyEpFilter

1.3.6.1.4.1.9.9.826.1.26.131.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyEp:filter managed object property

cfprFabricSspEthMonSrcPhyEpPcapfile

1.3.6.1.4.1.9.9.826.1.26.131.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyEp:pcapfile managed object property

cfprFabricSspEthMonSrcPhyEpPcapfilename

1.3.6.1.4.1.9.9.826.1.26.131.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyEp:pcapfilename managed object property

cfprFabricSspEthMonSrcPhyEpPcapsize

1.3.6.1.4.1.9.9.826.1.26.131.1.8

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyEp:pcapsize managed object property

cfprFabricSspEthMonSrcPhyEpPortId

1.3.6.1.4.1.9.9.826.1.26.131.1.9

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyEp:portId managed object property

cfprFabricSspEthMonSrcPhyEpSlotId

1.3.6.1.4.1.9.9.826.1.26.131.1.10

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyEp:slotId managed object property

cfprFabricSspEthMonSrcPhyEpSwitchId

1.3.6.1.4.1.9.9.826.1.26.131.1.11

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:SspEthMonSrcPhyEp:switchId managed object property

cfprFabricSspEthMonSrcPhyEpAppInstance

1.3.6.1.4.1.9.9.826.1.26.131.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyEp:appInstance managed object property

cfprFabricSspEthMonSrcPhyEpAppName

1.3.6.1.4.1.9.9.826.1.26.131.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspEthMonSrcPhyEp:appName managed object property

cfprFabricSspEthMonSrcPhyEpSubInterface

1.3.6.1.4.1.9.9.826.1.26.131.1.14

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyEp:subInterface managed object property

cfprFabricSspEthMonSrcPhyEpEcmpId

1.3.6.1.4.1.9.9.826.1.26.131.1.15

Gauge32

Cisco Firepower fabric:SspEthMonSrcPhyEp:ecmpId managed object property

cfprFabricSspLanMonCloudTable

1.3.6.1.4.1.9.9.826.1.26.132

Index: cfprFabricSspLanMonCloudInstanceId

Cisco Firepower fabric:SspLanMonCloud managed object table

cfprFabricSspLanMonCloudInstanceId

1.3.6.1.4.1.9.9.826.1.26.132.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSspLanMonCloudDn

1.3.6.1.4.1.9.9.826.1.26.132.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SspLanMonCloud:dn managed object property

cfprFabricSspLanMonCloudRn

1.3.6.1.4.1.9.9.826.1.26.132.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SspLanMonCloud:rn managed object property

cfprFabricSspLanMonCloudMode

1.3.6.1.4.1.9.9.826.1.26.132.1.4

CfprFabricSwitchingMode0 = endHost1 = switch2 = securityNode · Integer32

Cisco Firepower fabric:SspLanMonCloud:mode managed object property

cfprFabricSspLanMonCloudDelAllSess

1.3.6.1.4.1.9.9.826.1.26.132.1.5

CfprFabricSspLanMonCloudDelAllSess1 = enabled2 = disabled · Integer32

Cisco Firepower fabric:SspLanMonCloud:delAllSess managed object property

cfprFabricInnerVlanMgrTable

1.3.6.1.4.1.9.9.826.1.26.133

Index: cfprFabricInnerVlanMgrInstanceId

Cisco Firepower fabric:InnerVlanMgr managed object table

cfprFabricInnerVlanMgrInstanceId

1.3.6.1.4.1.9.9.826.1.26.133.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricInnerVlanMgrDn

1.3.6.1.4.1.9.9.826.1.26.133.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:InnerVlanMgr:dn managed object property

cfprFabricInnerVlanMgrRn

1.3.6.1.4.1.9.9.826.1.26.133.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:InnerVlanMgr:rn managed object property

cfprFabricInnerVlanMgrFltAggr

1.3.6.1.4.1.9.9.826.1.26.133.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower fabric:InnerVlanMgr:fltAggr managed object property

cfprFabricInnerVlanMgrId

1.3.6.1.4.1.9.9.826.1.26.133.1.5

CfprNetworkSwitchId0 = none1 = a2 = b · Integer32

Cisco Firepower fabric:InnerVlanMgr:id managed object property

cfprFabricSubIfTable

1.3.6.1.4.1.9.9.826.1.26.134

Index: cfprFabricSubIfInstanceId

Cisco Firepower fabric:SubIf managed object table

cfprFabricSubIfInstanceId

1.3.6.1.4.1.9.9.826.1.26.134.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprFabricSubIfDn

1.3.6.1.4.1.9.9.826.1.26.134.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower fabric:SubIf:dn managed object property

cfprFabricSubIfRn

1.3.6.1.4.1.9.9.826.1.26.134.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SubIf:rn managed object property

cfprFabricSubIfAllowSharing

1.3.6.1.4.1.9.9.826.1.26.134.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower fabric:SubIf:allowSharing managed object property

cfprFabricSubIfDescr

1.3.6.1.4.1.9.9.826.1.26.134.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SubIf:descr managed object property

cfprFabricSubIfIfName

1.3.6.1.4.1.9.9.826.1.26.134.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower fabric:SubIf:ifName managed object property

cfprFabricSubIfSsaPortType

1.3.6.1.4.1.9.9.826.1.26.134.1.7

CfprFabricSSASubPortType0 = data2 = cluster5 = dataSharing · Integer32

Cisco Firepower fabric:SubIf:ssaPortType managed object property

cfprFabricSubIfSubId

1.3.6.1.4.1.9.9.826.1.26.134.1.8

Gauge32

Cisco Firepower fabric:SubIf:subId managed object property

cfprFabricSubIfVlanId

1.3.6.1.4.1.9.9.826.1.26.134.1.9

INTEGER · Integer32

Cisco Firepower fabric:SubIf:vlanId managed object property

↑ To TOC