EZ5 MIB Catalog

CISCO-FIREPOWER-OS-MIB

2024-05-16

MIB representation of the Cisco Firepower OS management information model package

Download CISCO-FIREPOWER-OS-MIB.txt Open CISCO-FIREPOWER-OS-MIB.txt in a new tab

TABLES (6)

Tables (6)

NameOID
cfprOsAgentTable1.3.6.1.4.1.9.9.826.1.59.1
cfprOsControllerTable1.3.6.1.4.1.9.9.826.1.59.2
cfprOsControllerFsmTable1.3.6.1.4.1.9.9.826.1.59.3
cfprOsControllerFsmStageTable1.3.6.1.4.1.9.9.826.1.59.4
cfprOsControllerFsmTaskTable1.3.6.1.4.1.9.9.826.1.59.5
cfprOsInstanceTable1.3.6.1.4.1.9.9.826.1.59.6

END OF TOC

Table details

cfprOsAgentTable

1.3.6.1.4.1.9.9.826.1.59.1

Index: cfprOsAgentInstanceId

Cisco Firepower os:Agent managed object table

cfprOsAgentInstanceId

1.3.6.1.4.1.9.9.826.1.59.1.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprOsAgentDn

1.3.6.1.4.1.9.9.826.1.59.1.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower os:Agent:dn managed object property

cfprOsAgentRn

1.3.6.1.4.1.9.9.826.1.59.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Agent:rn managed object property

cfprOsAgentLastCmd

1.3.6.1.4.1.9.9.826.1.59.1.1.4

CfprHostagAction0 = none · Integer32

Cisco Firepower os:Agent:lastCmd managed object property

cfprOsAgentLastEvt

1.3.6.1.4.1.9.9.826.1.59.1.1.5

CfprHostagEvent0 = none · Integer32

Cisco Firepower os:Agent:lastEvt managed object property

cfprOsAgentLastEvtTs

1.3.6.1.4.1.9.9.826.1.59.1.1.6

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower os:Agent:lastEvtTs managed object property

cfprOsAgentPrevCmd

1.3.6.1.4.1.9.9.826.1.59.1.1.7

CfprHostagAction0 = none · Integer32

Cisco Firepower os:Agent:prevCmd managed object property

cfprOsAgentPrevEvt

1.3.6.1.4.1.9.9.826.1.59.1.1.8

CfprHostagEvent0 = none · Integer32

Cisco Firepower os:Agent:prevEvt managed object property

cfprOsAgentType

1.3.6.1.4.1.9.9.826.1.59.1.1.9

CfprHostagAgentType0 = indeterminate1 = pnuosAgent2 = hostAgent · Integer32

Cisco Firepower os:Agent:type managed object property

cfprOsAgentVendor

1.3.6.1.4.1.9.9.826.1.59.1.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Agent:vendor managed object property

cfprOsAgentVersion

1.3.6.1.4.1.9.9.826.1.59.1.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Agent:version managed object property

cfprOsControllerTable

1.3.6.1.4.1.9.9.826.1.59.2

Index: cfprOsControllerInstanceId

Cisco Firepower os:Controller managed object table

cfprOsControllerInstanceId

1.3.6.1.4.1.9.9.826.1.59.2.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprOsControllerDn

1.3.6.1.4.1.9.9.826.1.59.2.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower os:Controller:dn managed object property

cfprOsControllerRn

1.3.6.1.4.1.9.9.826.1.59.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:rn managed object property

cfprOsControllerBootMode

1.3.6.1.4.1.9.9.826.1.59.2.1.4

CfprOsControllerBootMode0 = normal1 = local2 = mio · Integer32

Cisco Firepower os:Controller:bootMode managed object property

cfprOsControllerChassisId

1.3.6.1.4.1.9.9.826.1.59.2.1.5

Gauge32

Cisco Firepower os:Controller:chassisId managed object property

cfprOsControllerDeployState

1.3.6.1.4.1.9.9.826.1.59.2.1.6

CfprOsDeployState0 = undefined1 = inProgress2 = complete3 = retry4 = failed5 = throttled · Integer32

Cisco Firepower os:Controller:deployState managed object property

cfprOsControllerEnableDeployOS

1.3.6.1.4.1.9.9.826.1.59.2.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower os:Controller:enableDeployOS managed object property

cfprOsControllerFormatDisk

1.3.6.1.4.1.9.9.826.1.59.2.1.8

CfprOsControllerFormatDisk0 = noOp1 = quickFormat2 = secureErase · Integer32

Cisco Firepower os:Controller:formatDisk managed object property

cfprOsControllerFsmDescr

1.3.6.1.4.1.9.9.826.1.59.2.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:fsmDescr managed object property

cfprOsControllerFsmFlags

1.3.6.1.4.1.9.9.826.1.59.2.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:fsmFlags managed object property

cfprOsControllerFsmPrev

1.3.6.1.4.1.9.9.826.1.59.2.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:fsmPrev managed object property

cfprOsControllerFsmProgr

1.3.6.1.4.1.9.9.826.1.59.2.1.12

Gauge32

Cisco Firepower os:Controller:fsmProgr managed object property

cfprOsControllerFsmRmtInvErrCode

1.3.6.1.4.1.9.9.826.1.59.2.1.13

Gauge32

Cisco Firepower os:Controller:fsmRmtInvErrCode managed object property

cfprOsControllerFsmRmtInvErrDescr

1.3.6.1.4.1.9.9.826.1.59.2.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:fsmRmtInvErrDescr managed object property

cfprOsControllerFsmRmtInvRslt

1.3.6.1.4.1.9.9.826.1.59.2.1.15

CfprConditionRemoteInvRslt · BITS

Cisco Firepower os:Controller:fsmRmtInvRslt managed object property

cfprOsControllerFsmStageDescr

1.3.6.1.4.1.9.9.826.1.59.2.1.16

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:fsmStageDescr managed object property

cfprOsControllerFsmStamp

1.3.6.1.4.1.9.9.826.1.59.2.1.17

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower os:Controller:fsmStamp managed object property

cfprOsControllerFsmStatus

1.3.6.1.4.1.9.9.826.1.59.2.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:fsmStatus managed object property

cfprOsControllerFsmTry

1.3.6.1.4.1.9.9.826.1.59.2.1.19

Gauge32

Cisco Firepower os:Controller:fsmTry managed object property

cfprOsControllerHostname

1.3.6.1.4.1.9.9.826.1.59.2.1.20

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:hostname managed object property

cfprOsControllerImageName

1.3.6.1.4.1.9.9.826.1.59.2.1.21

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:imageName managed object property

cfprOsControllerImageSize

1.3.6.1.4.1.9.9.826.1.59.2.1.22

Gauge32

Cisco Firepower os:Controller:imageSize managed object property

cfprOsControllerInitState

1.3.6.1.4.1.9.9.826.1.59.2.1.23

CfprOsInitState0 = undefined1 = inProgress2 = complete3 = retry4 = failed5 = throttled · Integer32

Cisco Firepower os:Controller:initState managed object property

cfprOsControllerMaxNumDeployFailureRecovery

1.3.6.1.4.1.9.9.826.1.59.2.1.24

Gauge32

Cisco Firepower os:Controller:maxNumDeployFailureRecovery managed object property

cfprOsControllerMaxNumberVersionMismatched

1.3.6.1.4.1.9.9.826.1.59.2.1.25

Gauge32

Cisco Firepower os:Controller:maxNumberVersionMismatched managed object property

cfprOsControllerModel

1.3.6.1.4.1.9.9.826.1.59.2.1.26

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:model managed object property

cfprOsControllerName

1.3.6.1.4.1.9.9.826.1.59.2.1.27

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:name managed object property

cfprOsControllerNumDeployFailureRecovery

1.3.6.1.4.1.9.9.826.1.59.2.1.28

Gauge32

Cisco Firepower os:Controller:numDeployFailureRecovery managed object property

cfprOsControllerNumberVersionMismatched

1.3.6.1.4.1.9.9.826.1.59.2.1.29

Gauge32

Cisco Firepower os:Controller:numberVersionMismatched managed object property

cfprOsControllerPnDn

1.3.6.1.4.1.9.9.826.1.59.2.1.30

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:pnDn managed object property

cfprOsControllerRevision

1.3.6.1.4.1.9.9.826.1.59.2.1.31

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:revision managed object property

cfprOsControllerRommonBuildDate

1.3.6.1.4.1.9.9.826.1.59.2.1.32

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:rommonBuildDate managed object property

cfprOsControllerRommonVersion

1.3.6.1.4.1.9.9.826.1.59.2.1.33

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:rommonVersion managed object property

cfprOsControllerSerial

1.3.6.1.4.1.9.9.826.1.59.2.1.34

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:serial managed object property

cfprOsControllerServiceStatus

1.3.6.1.4.1.9.9.826.1.59.2.1.35

CfprOsBootingUpType0 = outOfService1 = bootingUp2 = inService3 = failure · Integer32

Cisco Firepower os:Controller:serviceStatus managed object property

cfprOsControllerSlotId

1.3.6.1.4.1.9.9.826.1.59.2.1.36

Gauge32

Cisco Firepower os:Controller:slotId managed object property

cfprOsControllerSsposMode

1.3.6.1.4.1.9.9.826.1.59.2.1.37

CfprOsOsMode0 = normal1 = failsafe · Integer32

Cisco Firepower os:Controller:ssposMode managed object property

cfprOsControllerSupportTftpboot

1.3.6.1.4.1.9.9.826.1.59.2.1.38

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower os:Controller:supportTftpboot managed object property

cfprOsControllerType

1.3.6.1.4.1.9.9.826.1.59.2.1.39

CfprOsOsType0 = unspecified1 = pnuOS2 = linux3 = windows4 = solaris5 = vmwareESX6 = sspOS · Integer32

Cisco Firepower os:Controller:type managed object property

cfprOsControllerUpgradeState

1.3.6.1.4.1.9.9.826.1.59.2.1.40

CfprOsUpgradeState0 = undefined1 = inProgress2 = complete3 = retry4 = failed5 = throttled · Integer32

Cisco Firepower os:Controller:upgradeState managed object property

cfprOsControllerVendor

1.3.6.1.4.1.9.9.826.1.59.2.1.41

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:vendor managed object property

cfprOsControllerVersion

1.3.6.1.4.1.9.9.826.1.59.2.1.42

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:version managed object property

cfprOsControllerDmaSize

1.3.6.1.4.1.9.9.826.1.59.2.1.43

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:dmaSize managed object property

cfprOsControllerHeapSize

1.3.6.1.4.1.9.9.826.1.59.2.1.44

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:heapSize managed object property

cfprOsControllerHugePageSize

1.3.6.1.4.1.9.9.826.1.59.2.1.45

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:hugePageSize managed object property

cfprOsControllerInstallLicenseState

1.3.6.1.4.1.9.9.826.1.59.2.1.46

CfprOsInstallLicenseState0 = undefined1 = inProgress2 = complete3 = retry4 = failed5 = throttled · Integer32

Cisco Firepower os:Controller:installLicenseState managed object property

cfprOsControllerNumHugePages

1.3.6.1.4.1.9.9.826.1.59.2.1.47

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:numHugePages managed object property

cfprOsControllerPti

1.3.6.1.4.1.9.9.826.1.59.2.1.48

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Controller:pti managed object property

cfprOsControllerSecSmack

1.3.6.1.4.1.9.9.826.1.59.2.1.49

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower os:Controller:secSmack managed object property

cfprOsControllerTurboMode

1.3.6.1.4.1.9.9.826.1.59.2.1.50

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower os:Controller:turboMode managed object property

cfprOsControllerFsmTable

1.3.6.1.4.1.9.9.826.1.59.3

Index: cfprOsControllerFsmInstanceId

Cisco Firepower os:ControllerFsm managed object table

cfprOsControllerFsmInstanceId

1.3.6.1.4.1.9.9.826.1.59.3.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprOsControllerFsmDn

1.3.6.1.4.1.9.9.826.1.59.3.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower os:ControllerFsm:dn managed object property

cfprOsControllerFsmRn

1.3.6.1.4.1.9.9.826.1.59.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:ControllerFsm:rn managed object property

cfprOsControllerFsmCompletionTime

1.3.6.1.4.1.9.9.826.1.59.3.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower os:ControllerFsm:completionTime managed object property

cfprOsControllerFsmCurrentFsm

1.3.6.1.4.1.9.9.826.1.59.3.1.5

CfprOsControllerFsmCurrentFsm0 = nop1640 = deployOS1729 = upgradeOS1735 = initOS1974 = installLicense · Integer32

Cisco Firepower os:ControllerFsm:currentFsm managed object property

cfprOsControllerFsmDescrData

1.3.6.1.4.1.9.9.826.1.59.3.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:ControllerFsm:descr managed object property

cfprOsControllerFsmFsmStatus

1.3.6.1.4.1.9.9.826.1.59.3.1.7

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower os:ControllerFsm:fsmStatus managed object property

cfprOsControllerFsmProgress

1.3.6.1.4.1.9.9.826.1.59.3.1.8

Gauge32

Cisco Firepower os:ControllerFsm:progress managed object property

cfprOsControllerFsmRmtErrCode

1.3.6.1.4.1.9.9.826.1.59.3.1.9

Gauge32

Cisco Firepower os:ControllerFsm:rmtErrCode managed object property

cfprOsControllerFsmRmtErrDescr

1.3.6.1.4.1.9.9.826.1.59.3.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:ControllerFsm:rmtErrDescr managed object property

cfprOsControllerFsmRmtRslt

1.3.6.1.4.1.9.9.826.1.59.3.1.11

CfprConditionRemoteInvRslt · BITS

Cisco Firepower os:ControllerFsm:rmtRslt managed object property

cfprOsControllerFsmStageTable

1.3.6.1.4.1.9.9.826.1.59.4

Index: cfprOsControllerFsmStageInstanceId

Cisco Firepower os:ControllerFsmStage managed object table

cfprOsControllerFsmStageInstanceId

1.3.6.1.4.1.9.9.826.1.59.4.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprOsControllerFsmStageDn

1.3.6.1.4.1.9.9.826.1.59.4.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower os:ControllerFsmStage:dn managed object property

cfprOsControllerFsmStageRn

1.3.6.1.4.1.9.9.826.1.59.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:ControllerFsmStage:rn managed object property

cfprOsControllerFsmStageDescrData

1.3.6.1.4.1.9.9.826.1.59.4.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:ControllerFsmStage:descr managed object property

cfprOsControllerFsmStageLastUpdateTime

1.3.6.1.4.1.9.9.826.1.59.4.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower os:ControllerFsmStage:lastUpdateTime managed object property

cfprOsControllerFsmStageName

1.3.6.1.4.1.9.9.826.1.59.4.1.6

CfprOsControllerFsmStageName0 = nop1640 = deployOSBegin1641 = deployOSHostPrepareBoot1642 = deployOSHostWaitForRommonReady1643 = deployOSHostCheckRommonReady1644 = deployOSHostCheckUpgradeImageStatus1648 = deployOSSuccess1649 = deployOSFail1725 = deployOSHostPrepareKeyFile1726 = deployOSHostWaitForRommonValidateImage1727 = deployOSHostCheckImageValidationStatus1728 = deployOSHostWaitForSspOsRunning1729 = upgradeOSBegin1730 = upgradeOSRequestToUpgrade1731 = upgradeOSHostWaitForUpgradeComplete1732 = upgradeOSRebootHostAfterUpgrade1733 = upgradeOSSuccess1734 = upgradeOSFail1735 = initOSBegin1736 = initOSHostPrepareBoot1737 = initOSRequestToUpgrade1738 = initOSHostWaitForUpgradeComplete1739 = initOSRebootHostAfterUpgrade1740 = initOSSuccess1741 = initOSFail1974 = installLicenseBegin1975 = installLicenseRequestToUninstallLicense1976 = installLicenseRequestToInstallLicense1977 = installLicenseWaitForLicInstalledComplete1978 = installLicenseSuccess1979 = installLicenseFail1980 = initOSRequestToInstallLicense1981 = initOSHostWaitForLicInstalledComplete · Integer32

Cisco Firepower os:ControllerFsmStage:name managed object property

cfprOsControllerFsmStageOrder

1.3.6.1.4.1.9.9.826.1.59.4.1.7

Gauge32

Cisco Firepower os:ControllerFsmStage:order managed object property

cfprOsControllerFsmStageRetry

1.3.6.1.4.1.9.9.826.1.59.4.1.8

Gauge32

Cisco Firepower os:ControllerFsmStage:retry managed object property

cfprOsControllerFsmStageStageStatus

1.3.6.1.4.1.9.9.826.1.59.4.1.9

CfprFsmFsmStageStatus0 = fail1 = success2 = skip3 = pending4 = inProgress5 = throttled255 = nop · Integer32

Cisco Firepower os:ControllerFsmStage:stageStatus managed object property

cfprOsControllerFsmTaskTable

1.3.6.1.4.1.9.9.826.1.59.5

Index: cfprOsControllerFsmTaskInstanceId

Cisco Firepower os:ControllerFsmTask managed object table

cfprOsControllerFsmTaskInstanceId

1.3.6.1.4.1.9.9.826.1.59.5.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprOsControllerFsmTaskDn

1.3.6.1.4.1.9.9.826.1.59.5.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower os:ControllerFsmTask:dn managed object property

cfprOsControllerFsmTaskRn

1.3.6.1.4.1.9.9.826.1.59.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:ControllerFsmTask:rn managed object property

cfprOsControllerFsmTaskCompletion

1.3.6.1.4.1.9.9.826.1.59.5.1.4

CfprFsmCompletion0 = scheduled1 = processing2 = completed3 = cancelled · Integer32

Cisco Firepower os:ControllerFsmTask:completion managed object property

cfprOsControllerFsmTaskFlags

1.3.6.1.4.1.9.9.826.1.59.5.1.5

CfprOsControllerFsmTaskFlags · BITS

Cisco Firepower os:ControllerFsmTask:flags managed object property

cfprOsControllerFsmTaskItem

1.3.6.1.4.1.9.9.826.1.59.5.1.6

CfprOsControllerFsmTaskItem0 = nop1640 = deployOS1729 = upgradeOS1735 = initOS1974 = installLicense · Integer32

Cisco Firepower os:ControllerFsmTask:item managed object property

cfprOsControllerFsmTaskSeqId

1.3.6.1.4.1.9.9.826.1.59.5.1.7

Gauge32

Cisco Firepower os:ControllerFsmTask:seqId managed object property

cfprOsInstanceTable

1.3.6.1.4.1.9.9.826.1.59.6

Index: cfprOsInstanceInstanceId

Cisco Firepower os:Instance managed object table

cfprOsInstanceInstanceId

1.3.6.1.4.1.9.9.826.1.59.6.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprOsInstanceDn

1.3.6.1.4.1.9.9.826.1.59.6.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower os:Instance:dn managed object property

cfprOsInstanceRn

1.3.6.1.4.1.9.9.826.1.59.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Instance:rn managed object property

cfprOsInstanceHostname

1.3.6.1.4.1.9.9.826.1.59.6.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Instance:hostname managed object property

cfprOsInstanceKernelName

1.3.6.1.4.1.9.9.826.1.59.6.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Instance:kernelName managed object property

cfprOsInstanceKernelRelease

1.3.6.1.4.1.9.9.826.1.59.6.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Instance:kernelRelease managed object property

cfprOsInstanceKernelVersion

1.3.6.1.4.1.9.9.826.1.59.6.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Instance:kernelVersion managed object property

cfprOsInstanceName

1.3.6.1.4.1.9.9.826.1.59.6.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower os:Instance:name managed object property

cfprOsInstanceType

1.3.6.1.4.1.9.9.826.1.59.6.1.9

CfprOsOsType0 = unspecified1 = pnuOS2 = linux3 = windows4 = solaris5 = vmwareESX6 = sspOS · Integer32

Cisco Firepower os:Instance:type managed object property

cfprOsInstanceUpgradeProgress

1.3.6.1.4.1.9.9.826.1.59.6.1.10

Gauge32

Cisco Firepower os:Instance:upgradeProgress managed object property

cfprOsInstanceUpgradeReturnCode

1.3.6.1.4.1.9.9.826.1.59.6.1.11

CfprOsUpgradeReturnCode0 = null1 = requesting2 = successful3 = downloading4 = validating5 = failedComm6 = failedDownloading7 = failedValidation · Integer32

Cisco Firepower os:Instance:upgradeReturnCode managed object property

↑ To TOC