CISCO-FIREPOWER-POWER-MIB

2024-05-16

MIB representation of the Cisco Firepower POWER management information model package

Download CISCO-FIREPOWER-POWER-MIB.txt Open CISCO-FIREPOWER-POWER-MIB.txt in a new tab

TABLES (14)

Tables (14)

NameOID
cfprPowerBudgetTable1.3.6.1.4.1.9.9.826.1.64.1
cfprPowerChassisMemberTable1.3.6.1.4.1.9.9.826.1.64.2
cfprPowerEpTable1.3.6.1.4.1.9.9.826.1.64.3
cfprPowerGroupTable1.3.6.1.4.1.9.9.826.1.64.4
cfprPowerGroupAdditionPolicyTable1.3.6.1.4.1.9.9.826.1.64.5
cfprPowerGroupQualTable1.3.6.1.4.1.9.9.826.1.64.6
cfprPowerGroupStatsTable1.3.6.1.4.1.9.9.826.1.64.7
cfprPowerGroupStatsHistTable1.3.6.1.4.1.9.9.826.1.64.8
cfprPowerMgmtPolicyTable1.3.6.1.4.1.9.9.826.1.64.9
cfprPowerPlacementTable1.3.6.1.4.1.9.9.826.1.64.10
cfprPowerPolicyTable1.3.6.1.4.1.9.9.826.1.64.11
cfprPowerPrioWghtTable1.3.6.1.4.1.9.9.826.1.64.12
cfprPowerProfiledPowerTable1.3.6.1.4.1.9.9.826.1.64.13
cfprPowerRackUnitMemberTable1.3.6.1.4.1.9.9.826.1.64.14

END OF TOC

Table details

cfprPowerBudgetTable

1.3.6.1.4.1.9.9.826.1.64.1

Index: cfprPowerBudgetInstanceId

Cisco Firepower power:Budget managed object table

cfprPowerBudgetInstanceId

1.3.6.1.4.1.9.9.826.1.64.1.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerBudgetDn

1.3.6.1.4.1.9.9.826.1.64.1.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Budget:dn managed object property

cfprPowerBudgetRn

1.3.6.1.4.1.9.9.826.1.64.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Budget:rn managed object property

cfprPowerBudgetAdminCommitted

1.3.6.1.4.1.9.9.826.1.64.1.1.4

Gauge32

Cisco Firepower power:Budget:adminCommitted managed object property

cfprPowerBudgetAdminFPLockState

1.3.6.1.4.1.9.9.826.1.64.1.1.5

CfprPowerLockState0 = unknown1 = locked2 = unlocked · Integer32

Cisco Firepower power:Budget:adminFPLockState managed object property

cfprPowerBudgetAdminPeak

1.3.6.1.4.1.9.9.826.1.64.1.1.6

Gauge32

Cisco Firepower power:Budget:adminPeak managed object property

cfprPowerBudgetAdminPeakNew

1.3.6.1.4.1.9.9.826.1.64.1.1.7

Gauge32

Cisco Firepower power:Budget:adminPeakNew managed object property

cfprPowerBudgetBootPower

1.3.6.1.4.1.9.9.826.1.64.1.1.8

Gauge32

Cisco Firepower power:Budget:bootPower managed object property

cfprPowerBudgetCapAction

1.3.6.1.4.1.9.9.826.1.64.1.1.9

CfprPowerCapAction0 = nothing1 = clockDown2 = throttled · Integer32

Cisco Firepower power:Budget:capAction managed object property

cfprPowerBudgetCatalogPower

1.3.6.1.4.1.9.9.826.1.64.1.1.10

Gauge32

Cisco Firepower power:Budget:catalogPower managed object property

cfprPowerBudgetChRsrvdPower

1.3.6.1.4.1.9.9.826.1.64.1.1.11

Gauge32

Cisco Firepower power:Budget:chRsrvdPower managed object property

cfprPowerBudgetCurrentPower

1.3.6.1.4.1.9.9.826.1.64.1.1.12

Gauge32

Cisco Firepower power:Budget:currentPower managed object property

cfprPowerBudgetDynRealloc

1.3.6.1.4.1.9.9.826.1.64.1.1.13

CfprPowerReallocation0 = chassis1 = none · Integer32

Cisco Firepower power:Budget:dynRealloc managed object property

cfprPowerBudgetGroupName

1.3.6.1.4.1.9.9.826.1.64.1.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Budget:groupName managed object property

cfprPowerBudgetIdlePower

1.3.6.1.4.1.9.9.826.1.64.1.1.15

Gauge32

Cisco Firepower power:Budget:idlePower managed object property

cfprPowerBudgetMaxPower

1.3.6.1.4.1.9.9.826.1.64.1.1.16

Gauge32

Cisco Firepower power:Budget:maxPower managed object property

cfprPowerBudgetMinPower

1.3.6.1.4.1.9.9.826.1.64.1.1.17

Gauge32

Cisco Firepower power:Budget:minPower managed object property

cfprPowerBudgetOperCommitted

1.3.6.1.4.1.9.9.826.1.64.1.1.18

Gauge32

Cisco Firepower power:Budget:operCommitted managed object property

cfprPowerBudgetOperFPLockState

1.3.6.1.4.1.9.9.826.1.64.1.1.19

CfprPowerLockState0 = unknown1 = locked2 = unlocked · Integer32

Cisco Firepower power:Budget:operFPLockState managed object property

cfprPowerBudgetOperMin

1.3.6.1.4.1.9.9.826.1.64.1.1.20

Gauge32

Cisco Firepower power:Budget:operMin managed object property

cfprPowerBudgetOperPeak

1.3.6.1.4.1.9.9.826.1.64.1.1.21

Gauge32

Cisco Firepower power:Budget:operPeak managed object property

cfprPowerBudgetOperProfMethod

1.3.6.1.4.1.9.9.826.1.64.1.1.22

CfprPowerProfilingMethod0 = unknown1 = default2 = static3 = pnuos4 = nodemgr · Integer32

Cisco Firepower power:Budget:operProfMethod managed object property

cfprPowerBudgetOperState

1.3.6.1.4.1.9.9.826.1.64.1.1.23

CfprPowerOperState0 = notCapped1 = budgeting2 = budgeted3 = deploying4 = deployed5 = discoveryRetry6 = nonCompliant7 = firmwareMismatch8 = discoveryBudgeted9 = unbudgeted · Integer32

Cisco Firepower power:Budget:operState managed object property

cfprPowerBudgetPrio

1.3.6.1.4.1.9.9.826.1.64.1.1.24

Gauge32

Cisco Firepower power:Budget:prio managed object property

cfprPowerBudgetProfMethod

1.3.6.1.4.1.9.9.826.1.64.1.1.25

CfprPowerProfilingMethod0 = unknown1 = default2 = static3 = pnuos4 = nodemgr · Integer32

Cisco Firepower power:Budget:profMethod managed object property

cfprPowerBudgetProfiling

1.3.6.1.4.1.9.9.826.1.64.1.1.26

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:Budget:profiling managed object property

cfprPowerBudgetPsuCapacity

1.3.6.1.4.1.9.9.826.1.64.1.1.27

Gauge32

Cisco Firepower power:Budget:psuCapacity managed object property

cfprPowerBudgetPsuLineMode

1.3.6.1.4.1.9.9.826.1.64.1.1.28

CfprPowerPsuLineMode0 = unknown1 = undetermined2 = highLine3 = lowLine4 = mixedLine5 = lowerLine6 = lowerDcLine · Integer32

Cisco Firepower power:Budget:psuLineMode managed object property

cfprPowerBudgetPsuState

1.3.6.1.4.1.9.9.826.1.64.1.1.29

CfprPowerPsuState0 = ok1 = insufficient · Integer32

Cisco Firepower power:Budget:psuState managed object property

cfprPowerBudgetScaledWt

1.3.6.1.4.1.9.9.826.1.64.1.1.30

Gauge32

Cisco Firepower power:Budget:scaledWt managed object property

cfprPowerBudgetStyle

1.3.6.1.4.1.9.9.826.1.64.1.1.31

CfprPowerMgmtStyle0 = manualPerBlade1 = intelligentPolicyDriven · Integer32

Cisco Firepower power:Budget:style managed object property

cfprPowerBudgetUpdateTime

1.3.6.1.4.1.9.9.826.1.64.1.1.32

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower power:Budget:updateTime managed object property

cfprPowerBudgetWeight

1.3.6.1.4.1.9.9.826.1.64.1.1.33

Gauge32

Cisco Firepower power:Budget:weight managed object property

cfprPowerChassisMemberTable

1.3.6.1.4.1.9.9.826.1.64.2

Index: cfprPowerChassisMemberInstanceId

Cisco Firepower power:ChassisMember managed object table

cfprPowerChassisMemberInstanceId

1.3.6.1.4.1.9.9.826.1.64.2.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerChassisMemberDn

1.3.6.1.4.1.9.9.826.1.64.2.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:ChassisMember:dn managed object property

cfprPowerChassisMemberRn

1.3.6.1.4.1.9.9.826.1.64.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:ChassisMember:rn managed object property

cfprPowerChassisMemberId

1.3.6.1.4.1.9.9.826.1.64.2.1.4

Gauge32

Cisco Firepower power:ChassisMember:id managed object property

cfprPowerChassisMemberOperState

1.3.6.1.4.1.9.9.826.1.64.2.1.5

CfprPowerMemberState0 = uninitialized1 = capOk2 = fwMismatch3 = psuInsufficient4 = psuRedundancyFailed5 = capInsufficient · Integer32

Cisco Firepower power:ChassisMember:operState managed object property

cfprPowerEpTable

1.3.6.1.4.1.9.9.826.1.64.3

Index: cfprPowerEpInstanceId

Cisco Firepower power:Ep managed object table

cfprPowerEpInstanceId

1.3.6.1.4.1.9.9.826.1.64.3.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerEpDn

1.3.6.1.4.1.9.9.826.1.64.3.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Ep:dn managed object property

cfprPowerEpRn

1.3.6.1.4.1.9.9.826.1.64.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Ep:rn managed object property

cfprPowerGroupTable

1.3.6.1.4.1.9.9.826.1.64.4

Index: cfprPowerGroupInstanceId

Cisco Firepower power:Group managed object table

cfprPowerGroupInstanceId

1.3.6.1.4.1.9.9.826.1.64.4.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerGroupDn

1.3.6.1.4.1.9.9.826.1.64.4.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Group:dn managed object property

cfprPowerGroupRn

1.3.6.1.4.1.9.9.826.1.64.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:rn managed object property

cfprPowerGroupAdminCommitted

1.3.6.1.4.1.9.9.826.1.64.4.1.4

Gauge32

Cisco Firepower power:Group:adminCommitted managed object property

cfprPowerGroupAdminPeak

1.3.6.1.4.1.9.9.826.1.64.4.1.5

Gauge32

Cisco Firepower power:Group:adminPeak managed object property

cfprPowerGroupCurReqPower

1.3.6.1.4.1.9.9.826.1.64.4.1.6

Gauge32

Cisco Firepower power:Group:curReqPower managed object property

cfprPowerGroupCurrentPower

1.3.6.1.4.1.9.9.826.1.64.4.1.7

Gauge32

Cisco Firepower power:Group:currentPower managed object property

cfprPowerGroupDescr

1.3.6.1.4.1.9.9.826.1.64.4.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:descr managed object property

cfprPowerGroupFltAggr

1.3.6.1.4.1.9.9.826.1.64.4.1.9

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower power:Group:fltAggr managed object property

cfprPowerGroupIntId

1.3.6.1.4.1.9.9.826.1.64.4.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:intId managed object property

cfprPowerGroupMinReqPower

1.3.6.1.4.1.9.9.826.1.64.4.1.11

Gauge32

Cisco Firepower power:Group:minReqPower managed object property

cfprPowerGroupName

1.3.6.1.4.1.9.9.826.1.64.4.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:name managed object property

cfprPowerGroupOperCommitted

1.3.6.1.4.1.9.9.826.1.64.4.1.13

Gauge32

Cisco Firepower power:Group:operCommitted managed object property

cfprPowerGroupOperPeak

1.3.6.1.4.1.9.9.826.1.64.4.1.14

Gauge32

Cisco Firepower power:Group:operPeak managed object property

cfprPowerGroupOperState

1.3.6.1.4.1.9.9.826.1.64.4.1.15

CfprPowerGroupState · BITS

Cisco Firepower power:Group:operState managed object property

cfprPowerGroupPolicyLevel

1.3.6.1.4.1.9.9.826.1.64.4.1.16

Gauge32

Cisco Firepower power:Group:policyLevel managed object property

cfprPowerGroupPolicyOwner

1.3.6.1.4.1.9.9.826.1.64.4.1.17

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:Group:policyOwner managed object property

cfprPowerGroupQualifier

1.3.6.1.4.1.9.9.826.1.64.4.1.18

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Group:qualifier managed object property

cfprPowerGroupRealloc

1.3.6.1.4.1.9.9.826.1.64.4.1.19

CfprPowerReallocation0 = chassis1 = none · Integer32

Cisco Firepower power:Group:realloc managed object property

cfprPowerGroupAdditionPolicyTable

1.3.6.1.4.1.9.9.826.1.64.5

Index: cfprPowerGroupAdditionPolicyInstanceId

Cisco Firepower power:GroupAdditionPolicy managed object table

cfprPowerGroupAdditionPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.64.5.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerGroupAdditionPolicyDn

1.3.6.1.4.1.9.9.826.1.64.5.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupAdditionPolicy:dn managed object property

cfprPowerGroupAdditionPolicyRn

1.3.6.1.4.1.9.9.826.1.64.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:rn managed object property

cfprPowerGroupAdditionPolicyAction

1.3.6.1.4.1.9.9.826.1.64.5.1.4

CfprPowerChThrAction0 = nothing1 = throttleBladeDisc2 = stopBladeDisc · Integer32

Cisco Firepower power:GroupAdditionPolicy:action managed object property

cfprPowerGroupAdditionPolicyDescr

1.3.6.1.4.1.9.9.826.1.64.5.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:descr managed object property

cfprPowerGroupAdditionPolicyIntId

1.3.6.1.4.1.9.9.826.1.64.5.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:intId managed object property

cfprPowerGroupAdditionPolicyName

1.3.6.1.4.1.9.9.826.1.64.5.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupAdditionPolicy:name managed object property

cfprPowerGroupAdditionPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.64.5.1.8

Gauge32

Cisco Firepower power:GroupAdditionPolicy:policyLevel managed object property

cfprPowerGroupAdditionPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.64.5.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:GroupAdditionPolicy:policyOwner managed object property

cfprPowerGroupQualTable

1.3.6.1.4.1.9.9.826.1.64.6

Index: cfprPowerGroupQualInstanceId

Cisco Firepower power:GroupQual managed object table

cfprPowerGroupQualInstanceId

1.3.6.1.4.1.9.9.826.1.64.6.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerGroupQualDn

1.3.6.1.4.1.9.9.826.1.64.6.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupQual:dn managed object property

cfprPowerGroupQualRn

1.3.6.1.4.1.9.9.826.1.64.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupQual:rn managed object property

cfprPowerGroupQualGroupName

1.3.6.1.4.1.9.9.826.1.64.6.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupQual:groupName managed object property

cfprPowerGroupStatsTable

1.3.6.1.4.1.9.9.826.1.64.7

Index: cfprPowerGroupStatsInstanceId

Cisco Firepower power:GroupStats managed object table

cfprPowerGroupStatsInstanceId

1.3.6.1.4.1.9.9.826.1.64.7.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerGroupStatsDn

1.3.6.1.4.1.9.9.826.1.64.7.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupStats:dn managed object property

cfprPowerGroupStatsRn

1.3.6.1.4.1.9.9.826.1.64.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupStats:rn managed object property

cfprPowerGroupStatsIntervals

1.3.6.1.4.1.9.9.826.1.64.7.1.4

Gauge32

Cisco Firepower power:GroupStats:intervals managed object property

cfprPowerGroupStatsPower

1.3.6.1.4.1.9.9.826.1.64.7.1.5

INTEGER · Integer32

Cisco Firepower power:GroupStats:power managed object property

cfprPowerGroupStatsPowerAvg

1.3.6.1.4.1.9.9.826.1.64.7.1.6

INTEGER · Integer32

Cisco Firepower power:GroupStats:powerAvg managed object property

cfprPowerGroupStatsPowerMax

1.3.6.1.4.1.9.9.826.1.64.7.1.7

INTEGER · Integer32

Cisco Firepower power:GroupStats:powerMax managed object property

cfprPowerGroupStatsPowerMin

1.3.6.1.4.1.9.9.826.1.64.7.1.8

INTEGER · Integer32

Cisco Firepower power:GroupStats:powerMin managed object property

cfprPowerGroupStatsSuspect

1.3.6.1.4.1.9.9.826.1.64.7.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:GroupStats:suspect managed object property

cfprPowerGroupStatsThresholded

1.3.6.1.4.1.9.9.826.1.64.7.1.10

CfprPowerGroupStatsThresholded · BITS

Cisco Firepower power:GroupStats:thresholded managed object property

cfprPowerGroupStatsTimeCollected

1.3.6.1.4.1.9.9.826.1.64.7.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower power:GroupStats:timeCollected managed object property

cfprPowerGroupStatsUpdate

1.3.6.1.4.1.9.9.826.1.64.7.1.12

Gauge32

Cisco Firepower power:GroupStats:update managed object property

cfprPowerGroupStatsHistTable

1.3.6.1.4.1.9.9.826.1.64.8

Index: cfprPowerGroupStatsHistInstanceId

Cisco Firepower power:GroupStatsHist managed object table

cfprPowerGroupStatsHistInstanceId

1.3.6.1.4.1.9.9.826.1.64.8.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerGroupStatsHistDn

1.3.6.1.4.1.9.9.826.1.64.8.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:GroupStatsHist:dn managed object property

cfprPowerGroupStatsHistRn

1.3.6.1.4.1.9.9.826.1.64.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:GroupStatsHist:rn managed object property

cfprPowerGroupStatsHistId

1.3.6.1.4.1.9.9.826.1.64.8.1.4

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower power:GroupStatsHist:id managed object property

cfprPowerGroupStatsHistMostRecent

1.3.6.1.4.1.9.9.826.1.64.8.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:GroupStatsHist:mostRecent managed object property

cfprPowerGroupStatsHistPower

1.3.6.1.4.1.9.9.826.1.64.8.1.6

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:power managed object property

cfprPowerGroupStatsHistPowerAvg

1.3.6.1.4.1.9.9.826.1.64.8.1.7

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:powerAvg managed object property

cfprPowerGroupStatsHistPowerMax

1.3.6.1.4.1.9.9.826.1.64.8.1.8

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:powerMax managed object property

cfprPowerGroupStatsHistPowerMin

1.3.6.1.4.1.9.9.826.1.64.8.1.9

INTEGER · Integer32

Cisco Firepower power:GroupStatsHist:powerMin managed object property

cfprPowerGroupStatsHistSuspect

1.3.6.1.4.1.9.9.826.1.64.8.1.10

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:GroupStatsHist:suspect managed object property

cfprPowerGroupStatsHistThresholded

1.3.6.1.4.1.9.9.826.1.64.8.1.11

CfprPowerGroupStatsHistThresholded · BITS

Cisco Firepower power:GroupStatsHist:thresholded managed object property

cfprPowerGroupStatsHistTimeCollected

1.3.6.1.4.1.9.9.826.1.64.8.1.12

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower power:GroupStatsHist:timeCollected managed object property

cfprPowerMgmtPolicyTable

1.3.6.1.4.1.9.9.826.1.64.9

Index: cfprPowerMgmtPolicyInstanceId

Cisco Firepower power:MgmtPolicy managed object table

cfprPowerMgmtPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.64.9.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerMgmtPolicyDn

1.3.6.1.4.1.9.9.826.1.64.9.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:MgmtPolicy:dn managed object property

cfprPowerMgmtPolicyRn

1.3.6.1.4.1.9.9.826.1.64.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:rn managed object property

cfprPowerMgmtPolicyDescr

1.3.6.1.4.1.9.9.826.1.64.9.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:descr managed object property

cfprPowerMgmtPolicyIntId

1.3.6.1.4.1.9.9.826.1.64.9.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:intId managed object property

cfprPowerMgmtPolicyName

1.3.6.1.4.1.9.9.826.1.64.9.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:MgmtPolicy:name managed object property

cfprPowerMgmtPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.64.9.1.7

Gauge32

Cisco Firepower power:MgmtPolicy:policyLevel managed object property

cfprPowerMgmtPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.64.9.1.8

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:MgmtPolicy:policyOwner managed object property

cfprPowerMgmtPolicyProfiling

1.3.6.1.4.1.9.9.826.1.64.9.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:MgmtPolicy:profiling managed object property

cfprPowerMgmtPolicyStyle

1.3.6.1.4.1.9.9.826.1.64.9.1.10

CfprPowerMgmtStyle0 = manualPerBlade1 = intelligentPolicyDriven · Integer32

Cisco Firepower power:MgmtPolicy:style managed object property

cfprPowerPlacementTable

1.3.6.1.4.1.9.9.826.1.64.10

Index: cfprPowerPlacementInstanceId

Cisco Firepower power:Placement managed object table

cfprPowerPlacementInstanceId

1.3.6.1.4.1.9.9.826.1.64.10.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerPlacementDn

1.3.6.1.4.1.9.9.826.1.64.10.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Placement:dn managed object property

cfprPowerPlacementRn

1.3.6.1.4.1.9.9.826.1.64.10.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:rn managed object property

cfprPowerPlacementDescr

1.3.6.1.4.1.9.9.826.1.64.10.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:descr managed object property

cfprPowerPlacementIntId

1.3.6.1.4.1.9.9.826.1.64.10.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:intId managed object property

cfprPowerPlacementName

1.3.6.1.4.1.9.9.826.1.64.10.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:name managed object property

cfprPowerPlacementPeerReqConflict

1.3.6.1.4.1.9.9.826.1.64.10.1.7

CfprPowerReqConflict0 = ignore1 = failPlacement · Integer32

Cisco Firepower power:Placement:peerReqConflict managed object property

cfprPowerPlacementPgName

1.3.6.1.4.1.9.9.826.1.64.10.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Placement:pgName managed object property

cfprPowerPlacementPolicyLevel

1.3.6.1.4.1.9.9.826.1.64.10.1.9

Gauge32

Cisco Firepower power:Placement:policyLevel managed object property

cfprPowerPlacementPolicyOwner

1.3.6.1.4.1.9.9.826.1.64.10.1.10

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:Placement:policyOwner managed object property

cfprPowerPlacementPrioShare

1.3.6.1.4.1.9.9.826.1.64.10.1.11

CfprPowerPrioritySharing0 = noPreference1 = highestPrioInChassis2 = highestPrioInPowerGroup · Integer32

Cisco Firepower power:Placement:prioShare managed object property

cfprPowerPlacementSelfReqConflict

1.3.6.1.4.1.9.9.826.1.64.10.1.12

CfprPowerReqConflict0 = ignore1 = failPlacement · Integer32

Cisco Firepower power:Placement:selfReqConflict managed object property

cfprPowerPolicyTable

1.3.6.1.4.1.9.9.826.1.64.11

Index: cfprPowerPolicyInstanceId

Cisco Firepower power:Policy managed object table

cfprPowerPolicyInstanceId

1.3.6.1.4.1.9.9.826.1.64.11.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerPolicyDn

1.3.6.1.4.1.9.9.826.1.64.11.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:Policy:dn managed object property

cfprPowerPolicyRn

1.3.6.1.4.1.9.9.826.1.64.11.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:rn managed object property

cfprPowerPolicyDescr

1.3.6.1.4.1.9.9.826.1.64.11.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:descr managed object property

cfprPowerPolicyIntId

1.3.6.1.4.1.9.9.826.1.64.11.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:intId managed object property

cfprPowerPolicyName

1.3.6.1.4.1.9.9.826.1.64.11.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:Policy:name managed object property

cfprPowerPolicyOperPrio

1.3.6.1.4.1.9.9.826.1.64.11.1.7

Gauge32

Cisco Firepower power:Policy:operPrio managed object property

cfprPowerPolicyPolicyLevel

1.3.6.1.4.1.9.9.826.1.64.11.1.8

Gauge32

Cisco Firepower power:Policy:policyLevel managed object property

cfprPowerPolicyPolicyOwner

1.3.6.1.4.1.9.9.826.1.64.11.1.9

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower power:Policy:policyOwner managed object property

cfprPowerPolicyPrio

1.3.6.1.4.1.9.9.826.1.64.11.1.10

Gauge32

Cisco Firepower power:Policy:prio managed object property

cfprPowerPrioWghtTable

1.3.6.1.4.1.9.9.826.1.64.12

Index: cfprPowerPrioWghtInstanceId

Cisco Firepower power:PrioWght managed object table

cfprPowerPrioWghtInstanceId

1.3.6.1.4.1.9.9.826.1.64.12.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerPrioWghtDn

1.3.6.1.4.1.9.9.826.1.64.12.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:PrioWght:dn managed object property

cfprPowerPrioWghtRn

1.3.6.1.4.1.9.9.826.1.64.12.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:PrioWght:rn managed object property

cfprPowerPrioWghtPrio

1.3.6.1.4.1.9.9.826.1.64.12.1.4

Gauge32

Cisco Firepower power:PrioWght:prio managed object property

cfprPowerPrioWghtWeight

1.3.6.1.4.1.9.9.826.1.64.12.1.5

Gauge32

Cisco Firepower power:PrioWght:weight managed object property

cfprPowerProfiledPowerTable

1.3.6.1.4.1.9.9.826.1.64.13

Index: cfprPowerProfiledPowerInstanceId

Cisco Firepower power:ProfiledPower managed object table

cfprPowerProfiledPowerInstanceId

1.3.6.1.4.1.9.9.826.1.64.13.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerProfiledPowerDn

1.3.6.1.4.1.9.9.826.1.64.13.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:ProfiledPower:dn managed object property

cfprPowerProfiledPowerRn

1.3.6.1.4.1.9.9.826.1.64.13.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:ProfiledPower:rn managed object property

cfprPowerProfiledPowerAbsMinPostPower

1.3.6.1.4.1.9.9.826.1.64.13.1.4

Gauge32

Cisco Firepower power:ProfiledPower:absMinPostPower managed object property

cfprPowerProfiledPowerMaxAppPower

1.3.6.1.4.1.9.9.826.1.64.13.1.5

Gauge32

Cisco Firepower power:ProfiledPower:maxAppPower managed object property

cfprPowerProfiledPowerMaxPostPower

1.3.6.1.4.1.9.9.826.1.64.13.1.6

Gauge32

Cisco Firepower power:ProfiledPower:maxPostPower managed object property

cfprPowerProfiledPowerMinAppPower

1.3.6.1.4.1.9.9.826.1.64.13.1.7

Gauge32

Cisco Firepower power:ProfiledPower:minAppPower managed object property

cfprPowerProfiledPowerMinNormPostPower

1.3.6.1.4.1.9.9.826.1.64.13.1.8

Gauge32

Cisco Firepower power:ProfiledPower:minNormPostPower managed object property

cfprPowerProfiledPowerMinPostPower

1.3.6.1.4.1.9.9.826.1.64.13.1.9

Gauge32

Cisco Firepower power:ProfiledPower:minPostPower managed object property

cfprPowerProfiledPowerPreDiscoveryPower

1.3.6.1.4.1.9.9.826.1.64.13.1.10

Gauge32

Cisco Firepower power:ProfiledPower:preDiscoveryPower managed object property

cfprPowerProfiledPowerProfileRunTime

1.3.6.1.4.1.9.9.826.1.64.13.1.11

Gauge32

Cisco Firepower power:ProfiledPower:profileRunTime managed object property

cfprPowerProfiledPowerProfiledBoot

1.3.6.1.4.1.9.9.826.1.64.13.1.12

Gauge32

Cisco Firepower power:ProfiledPower:profiledBoot managed object property

cfprPowerProfiledPowerProfiledMax

1.3.6.1.4.1.9.9.826.1.64.13.1.13

Gauge32

Cisco Firepower power:ProfiledPower:profiledMax managed object property

cfprPowerProfiledPowerProfiledMin

1.3.6.1.4.1.9.9.826.1.64.13.1.14

Gauge32

Cisco Firepower power:ProfiledPower:profiledMin managed object property

cfprPowerProfiledPowerSkipProfiling

1.3.6.1.4.1.9.9.826.1.64.13.1.15

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower power:ProfiledPower:skipProfiling managed object property

cfprPowerRackUnitMemberTable

1.3.6.1.4.1.9.9.826.1.64.14

Index: cfprPowerRackUnitMemberInstanceId

Cisco Firepower power:RackUnitMember managed object table

cfprPowerRackUnitMemberInstanceId

1.3.6.1.4.1.9.9.826.1.64.14.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprPowerRackUnitMemberDn

1.3.6.1.4.1.9.9.826.1.64.14.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower power:RackUnitMember:dn managed object property

cfprPowerRackUnitMemberRn

1.3.6.1.4.1.9.9.826.1.64.14.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower power:RackUnitMember:rn managed object property

cfprPowerRackUnitMemberId

1.3.6.1.4.1.9.9.826.1.64.14.1.4

Gauge32

Cisco Firepower power:RackUnitMember:id managed object property

cfprPowerRackUnitMemberOperState

1.3.6.1.4.1.9.9.826.1.64.14.1.5

CfprPowerMemberState0 = uninitialized1 = capOk2 = fwMismatch3 = psuInsufficient4 = psuRedundancyFailed5 = capInsufficient · Integer32

Cisco Firepower power:RackUnitMember:operState managed object property

↑ To TOC