EZ5 MIB Catalog

CISCO-FIREPOWER-QUERYRESULT-MIB

2024-05-16

MIB representation of the Cisco Firepower QUERYRESULT management information model package

Download CISCO-FIREPOWER-QUERYRESULT-MIB.txt Open CISCO-FIREPOWER-QUERYRESULT-MIB.txt in a new tab

TABLES (2)

Tables (2)

NameOID
cfprQueryresultDependencyTable1.3.6.1.4.1.9.9.826.1.68.1
cfprQueryresultUsageTable1.3.6.1.4.1.9.9.826.1.68.2

END OF TOC

Table details

cfprQueryresultDependencyTable

1.3.6.1.4.1.9.9.826.1.68.1

Index: cfprQueryresultDependencyInstanceId

Cisco Firepower queryresult:Dependency managed object table

cfprQueryresultDependencyInstanceId

1.3.6.1.4.1.9.9.826.1.68.1.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprQueryresultDependencyDn

1.3.6.1.4.1.9.9.826.1.68.1.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower queryresult:Dependency:dn managed object property

cfprQueryresultDependencyRn

1.3.6.1.4.1.9.9.826.1.68.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Dependency:rn managed object property

cfprQueryresultDependencyClassType

1.3.6.1.4.1.9.9.826.1.68.1.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Dependency:classType managed object property

cfprQueryresultDependencyIsImportable

1.3.6.1.4.1.9.9.826.1.68.1.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower queryresult:Dependency:isImportable managed object property

cfprQueryresultDependencyPolicyOwner

1.3.6.1.4.1.9.9.826.1.68.1.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Dependency:policyOwner managed object property

cfprQueryresultDependencyRefConvertedDn

1.3.6.1.4.1.9.9.826.1.68.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Dependency:refConvertedDn managed object property

cfprQueryresultDependencyRefDn

1.3.6.1.4.1.9.9.826.1.68.1.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Dependency:refDn managed object property

cfprQueryresultDependencyRefName

1.3.6.1.4.1.9.9.826.1.68.1.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Dependency:refName managed object property

cfprQueryresultUsageTable

1.3.6.1.4.1.9.9.826.1.68.2

Index: cfprQueryresultUsageInstanceId

Cisco Firepower queryresult:Usage managed object table

cfprQueryresultUsageInstanceId

1.3.6.1.4.1.9.9.826.1.68.2.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprQueryresultUsageDn

1.3.6.1.4.1.9.9.826.1.68.2.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower queryresult:Usage:dn managed object property

cfprQueryresultUsageRn

1.3.6.1.4.1.9.9.826.1.68.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Usage:rn managed object property

cfprQueryresultUsageClassType

1.3.6.1.4.1.9.9.826.1.68.2.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Usage:classType managed object property

cfprQueryresultUsageIsServiceTemplate

1.3.6.1.4.1.9.9.826.1.68.2.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower queryresult:Usage:isServiceTemplate managed object property

cfprQueryresultUsagePolicyOwner

1.3.6.1.4.1.9.9.826.1.68.2.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Usage:policyOwner managed object property

cfprQueryresultUsageRefConvertedDn

1.3.6.1.4.1.9.9.826.1.68.2.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Usage:refConvertedDn managed object property

cfprQueryresultUsageRefDn

1.3.6.1.4.1.9.9.826.1.68.2.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Usage:refDn managed object property

cfprQueryresultUsageRefName

1.3.6.1.4.1.9.9.826.1.68.2.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower queryresult:Usage:refName managed object property

↑ To TOC