CISCO-FIREPOWER-TRIG-MIB

2024-05-16

MIB representation of the Cisco Firepower TRIG management information model package

Download CISCO-FIREPOWER-TRIG-MIB.txt Open CISCO-FIREPOWER-TRIG-MIB.txt in a new tab

TABLES (9)

Tables (9)

NameOID
cfprTrigAbsWindowTable1.3.6.1.4.1.9.9.826.1.79.1
cfprTrigClientTokenTable1.3.6.1.4.1.9.9.826.1.79.2
cfprTrigLocalAbsWindowTable1.3.6.1.4.1.9.9.826.1.79.3
cfprTrigLocalSchedTable1.3.6.1.4.1.9.9.826.1.79.4
cfprTrigMetaTable1.3.6.1.4.1.9.9.826.1.79.5
cfprTrigRecurrWindowTable1.3.6.1.4.1.9.9.826.1.79.6
cfprTrigSchedTable1.3.6.1.4.1.9.9.826.1.79.7
cfprTrigTestTable1.3.6.1.4.1.9.9.826.1.79.8
cfprTrigTriggeredTable1.3.6.1.4.1.9.9.826.1.79.9

END OF TOC

Table details

cfprTrigAbsWindowTable

1.3.6.1.4.1.9.9.826.1.79.1

Index: cfprTrigAbsWindowInstanceId

Cisco Firepower trig:AbsWindow managed object table

cfprTrigAbsWindowInstanceId

1.3.6.1.4.1.9.9.826.1.79.1.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigAbsWindowDn

1.3.6.1.4.1.9.9.826.1.79.1.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:AbsWindow:dn managed object property

cfprTrigAbsWindowRn

1.3.6.1.4.1.9.9.826.1.79.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:AbsWindow:rn managed object property

cfprTrigAbsWindowConcurCap

1.3.6.1.4.1.9.9.826.1.79.1.1.4

Gauge32

Cisco Firepower trig:AbsWindow:concurCap managed object property

cfprTrigAbsWindowDate

1.3.6.1.4.1.9.9.826.1.79.1.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower trig:AbsWindow:date managed object property

cfprTrigAbsWindowJobCount

1.3.6.1.4.1.9.9.826.1.79.1.1.6

Gauge32

Cisco Firepower trig:AbsWindow:jobCount managed object property

cfprTrigAbsWindowName

1.3.6.1.4.1.9.9.826.1.79.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:AbsWindow:name managed object property

cfprTrigAbsWindowProcBreak

1.3.6.1.4.1.9.9.826.1.79.1.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:AbsWindow:procBreak managed object property

cfprTrigAbsWindowProcCap

1.3.6.1.4.1.9.9.826.1.79.1.1.9

Gauge32

Cisco Firepower trig:AbsWindow:procCap managed object property

cfprTrigAbsWindowTimeCap

1.3.6.1.4.1.9.9.826.1.79.1.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:AbsWindow:timeCap managed object property

cfprTrigAbsWindowStart

1.3.6.1.4.1.9.9.826.1.79.1.1.11

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower trig:AbsWindow:start managed object property

cfprTrigClientTokenTable

1.3.6.1.4.1.9.9.826.1.79.2

Index: cfprTrigClientTokenInstanceId

Cisco Firepower trig:ClientToken managed object table

cfprTrigClientTokenInstanceId

1.3.6.1.4.1.9.9.826.1.79.2.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigClientTokenDn

1.3.6.1.4.1.9.9.826.1.79.2.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:ClientToken:dn managed object property

cfprTrigClientTokenRn

1.3.6.1.4.1.9.9.826.1.79.2.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:ClientToken:rn managed object property

cfprTrigClientTokenActivityTs

1.3.6.1.4.1.9.9.826.1.79.2.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower trig:ClientToken:activityTs managed object property

cfprTrigClientTokenId

1.3.6.1.4.1.9.9.826.1.79.2.1.5

Unsigned64An unsigned 64 bit integer. We use SYNTAX Counter64 for the encoding rules. (0..18446744073709551615) · Counter64

Cisco Firepower trig:ClientToken:id managed object property

cfprTrigClientTokenOperState

1.3.6.1.4.1.9.9.826.1.79.2.1.6

CfprTrigTokenOperState0 = valid1 = expired · Integer32

Cisco Firepower trig:ClientToken:operState managed object property

cfprTrigLocalAbsWindowTable

1.3.6.1.4.1.9.9.826.1.79.3

Index: cfprTrigLocalAbsWindowInstanceId

Cisco Firepower trig:LocalAbsWindow managed object table

cfprTrigLocalAbsWindowInstanceId

1.3.6.1.4.1.9.9.826.1.79.3.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigLocalAbsWindowDn

1.3.6.1.4.1.9.9.826.1.79.3.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:LocalAbsWindow:dn managed object property

cfprTrigLocalAbsWindowRn

1.3.6.1.4.1.9.9.826.1.79.3.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalAbsWindow:rn managed object property

cfprTrigLocalAbsWindowConcurCap

1.3.6.1.4.1.9.9.826.1.79.3.1.4

Gauge32

Cisco Firepower trig:LocalAbsWindow:concurCap managed object property

cfprTrigLocalAbsWindowDate

1.3.6.1.4.1.9.9.826.1.79.3.1.5

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower trig:LocalAbsWindow:date managed object property

cfprTrigLocalAbsWindowJobCount

1.3.6.1.4.1.9.9.826.1.79.3.1.6

Gauge32

Cisco Firepower trig:LocalAbsWindow:jobCount managed object property

cfprTrigLocalAbsWindowName

1.3.6.1.4.1.9.9.826.1.79.3.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalAbsWindow:name managed object property

cfprTrigLocalAbsWindowProcBreak

1.3.6.1.4.1.9.9.826.1.79.3.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalAbsWindow:procBreak managed object property

cfprTrigLocalAbsWindowProcCap

1.3.6.1.4.1.9.9.826.1.79.3.1.9

Gauge32

Cisco Firepower trig:LocalAbsWindow:procCap managed object property

cfprTrigLocalAbsWindowTimeCap

1.3.6.1.4.1.9.9.826.1.79.3.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalAbsWindow:timeCap managed object property

cfprTrigLocalAbsWindowStart

1.3.6.1.4.1.9.9.826.1.79.3.1.11

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower trig:LocalAbsWindow:start managed object property

cfprTrigLocalSchedTable

1.3.6.1.4.1.9.9.826.1.79.4

Index: cfprTrigLocalSchedInstanceId

Cisco Firepower trig:LocalSched managed object table

cfprTrigLocalSchedInstanceId

1.3.6.1.4.1.9.9.826.1.79.4.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigLocalSchedDn

1.3.6.1.4.1.9.9.826.1.79.4.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:LocalSched:dn managed object property

cfprTrigLocalSchedRn

1.3.6.1.4.1.9.9.826.1.79.4.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalSched:rn managed object property

cfprTrigLocalSchedAdminState

1.3.6.1.4.1.9.9.826.1.79.4.1.4

CfprTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower trig:LocalSched:adminState managed object property

cfprTrigLocalSchedDescr

1.3.6.1.4.1.9.9.826.1.79.4.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalSched:descr managed object property

cfprTrigLocalSchedFlgInitialActive

1.3.6.1.4.1.9.9.826.1.79.4.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower trig:LocalSched:flgInitialActive managed object property

cfprTrigLocalSchedIntId

1.3.6.1.4.1.9.9.826.1.79.4.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalSched:intId managed object property

cfprTrigLocalSchedName

1.3.6.1.4.1.9.9.826.1.79.4.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:LocalSched:name managed object property

cfprTrigLocalSchedOperState

1.3.6.1.4.1.9.9.826.1.79.4.1.9

CfprTrigOperState0 = pending1 = inProgress2 = failed3 = triggered4 = capReached · Integer32

Cisco Firepower trig:LocalSched:operState managed object property

cfprTrigLocalSchedPolicyLevel

1.3.6.1.4.1.9.9.826.1.79.4.1.10

Gauge32

Cisco Firepower trig:LocalSched:policyLevel managed object property

cfprTrigLocalSchedPolicyOwner

1.3.6.1.4.1.9.9.826.1.79.4.1.11

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower trig:LocalSched:policyOwner managed object property

cfprTrigMetaTable

1.3.6.1.4.1.9.9.826.1.79.5

Index: cfprTrigMetaInstanceId

Cisco Firepower trig:Meta managed object table

cfprTrigMetaInstanceId

1.3.6.1.4.1.9.9.826.1.79.5.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigMetaDn

1.3.6.1.4.1.9.9.826.1.79.5.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:Meta:dn managed object property

cfprTrigMetaRn

1.3.6.1.4.1.9.9.826.1.79.5.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Meta:rn managed object property

cfprTrigMetaAdminState

1.3.6.1.4.1.9.9.826.1.79.5.1.4

CfprTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower trig:Meta:adminState managed object property

cfprTrigMetaDescr

1.3.6.1.4.1.9.9.826.1.79.5.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Meta:descr managed object property

cfprTrigMetaIntId

1.3.6.1.4.1.9.9.826.1.79.5.1.6

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Meta:intId managed object property

cfprTrigMetaJobCount

1.3.6.1.4.1.9.9.826.1.79.5.1.7

Gauge32

Cisco Firepower trig:Meta:jobCount managed object property

cfprTrigMetaName

1.3.6.1.4.1.9.9.826.1.79.5.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Meta:name managed object property

cfprTrigMetaOperState

1.3.6.1.4.1.9.9.826.1.79.5.1.9

CfprTrigOperState0 = pending1 = inProgress2 = failed3 = triggered4 = capReached · Integer32

Cisco Firepower trig:Meta:operState managed object property

cfprTrigMetaPolicyLevel

1.3.6.1.4.1.9.9.826.1.79.5.1.10

Gauge32

Cisco Firepower trig:Meta:policyLevel managed object property

cfprTrigMetaPolicyOwner

1.3.6.1.4.1.9.9.826.1.79.5.1.11

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower trig:Meta:policyOwner managed object property

cfprTrigMetaSchedName

1.3.6.1.4.1.9.9.826.1.79.5.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Meta:schedName managed object property

cfprTrigMetaTrigTime

1.3.6.1.4.1.9.9.826.1.79.5.1.13

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower trig:Meta:trigTime managed object property

cfprTrigMetaWindowDn

1.3.6.1.4.1.9.9.826.1.79.5.1.14

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Meta:windowDn managed object property

cfprTrigRecurrWindowTable

1.3.6.1.4.1.9.9.826.1.79.6

Index: cfprTrigRecurrWindowInstanceId

Cisco Firepower trig:RecurrWindow managed object table

cfprTrigRecurrWindowInstanceId

1.3.6.1.4.1.9.9.826.1.79.6.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigRecurrWindowDn

1.3.6.1.4.1.9.9.826.1.79.6.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:RecurrWindow:dn managed object property

cfprTrigRecurrWindowRn

1.3.6.1.4.1.9.9.826.1.79.6.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:RecurrWindow:rn managed object property

cfprTrigRecurrWindowConcurCap

1.3.6.1.4.1.9.9.826.1.79.6.1.4

Gauge32

Cisco Firepower trig:RecurrWindow:concurCap managed object property

cfprTrigRecurrWindowDay

1.3.6.1.4.1.9.9.826.1.79.6.1.5

CfprTrigDay0 = everyDay1 = monday2 = tuesday3 = wednesday4 = thursday5 = friday6 = saturday7 = sunday8 = oddDay9 = evenDay · Integer32

Cisco Firepower trig:RecurrWindow:day managed object property

cfprTrigRecurrWindowHour

1.3.6.1.4.1.9.9.826.1.79.6.1.6

Gauge32

Cisco Firepower trig:RecurrWindow:hour managed object property

cfprTrigRecurrWindowJobCount

1.3.6.1.4.1.9.9.826.1.79.6.1.7

Gauge32

Cisco Firepower trig:RecurrWindow:jobCount managed object property

cfprTrigRecurrWindowMinute

1.3.6.1.4.1.9.9.826.1.79.6.1.8

Gauge32

Cisco Firepower trig:RecurrWindow:minute managed object property

cfprTrigRecurrWindowName

1.3.6.1.4.1.9.9.826.1.79.6.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:RecurrWindow:name managed object property

cfprTrigRecurrWindowProcBreak

1.3.6.1.4.1.9.9.826.1.79.6.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:RecurrWindow:procBreak managed object property

cfprTrigRecurrWindowProcCap

1.3.6.1.4.1.9.9.826.1.79.6.1.11

Gauge32

Cisco Firepower trig:RecurrWindow:procCap managed object property

cfprTrigRecurrWindowTimeCap

1.3.6.1.4.1.9.9.826.1.79.6.1.12

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:RecurrWindow:timeCap managed object property

cfprTrigSchedTable

1.3.6.1.4.1.9.9.826.1.79.7

Index: cfprTrigSchedInstanceId

Cisco Firepower trig:Sched managed object table

cfprTrigSchedInstanceId

1.3.6.1.4.1.9.9.826.1.79.7.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigSchedDn

1.3.6.1.4.1.9.9.826.1.79.7.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:Sched:dn managed object property

cfprTrigSchedRn

1.3.6.1.4.1.9.9.826.1.79.7.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Sched:rn managed object property

cfprTrigSchedAdminState

1.3.6.1.4.1.9.9.826.1.79.7.1.4

CfprTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower trig:Sched:adminState managed object property

cfprTrigSchedDescr

1.3.6.1.4.1.9.9.826.1.79.7.1.5

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Sched:descr managed object property

cfprTrigSchedFlgInitialActive

1.3.6.1.4.1.9.9.826.1.79.7.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower trig:Sched:flgInitialActive managed object property

cfprTrigSchedIntId

1.3.6.1.4.1.9.9.826.1.79.7.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Sched:intId managed object property

cfprTrigSchedName

1.3.6.1.4.1.9.9.826.1.79.7.1.8

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Sched:name managed object property

cfprTrigSchedOperState

1.3.6.1.4.1.9.9.826.1.79.7.1.9

CfprTrigOperState0 = pending1 = inProgress2 = failed3 = triggered4 = capReached · Integer32

Cisco Firepower trig:Sched:operState managed object property

cfprTrigSchedPolicyLevel

1.3.6.1.4.1.9.9.826.1.79.7.1.10

Gauge32

Cisco Firepower trig:Sched:policyLevel managed object property

cfprTrigSchedPolicyOwner

1.3.6.1.4.1.9.9.826.1.79.7.1.11

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower trig:Sched:policyOwner managed object property

cfprTrigTestTable

1.3.6.1.4.1.9.9.826.1.79.8

Index: cfprTrigTestInstanceId

Cisco Firepower trig:Test managed object table

cfprTrigTestInstanceId

1.3.6.1.4.1.9.9.826.1.79.8.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigTestDn

1.3.6.1.4.1.9.9.826.1.79.8.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:Test:dn managed object property

cfprTrigTestRn

1.3.6.1.4.1.9.9.826.1.79.8.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Test:rn managed object property

cfprTrigTestAdminState

1.3.6.1.4.1.9.9.826.1.79.8.1.4

CfprTrigAdminState0 = triggerImmediate1 = trigger2 = triggered3 = untriggered4 = userAck5 = userDiscard · Integer32

Cisco Firepower trig:Test:adminState managed object property

cfprTrigTestAutoDelete

1.3.6.1.4.1.9.9.826.1.79.8.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower trig:Test:autoDelete managed object property

cfprTrigTestCreationDate

1.3.6.1.4.1.9.9.826.1.79.8.1.6

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

Cisco Firepower trig:Test:creationDate managed object property

cfprTrigTestDescr

1.3.6.1.4.1.9.9.826.1.79.8.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Test:descr managed object property

cfprTrigTestIgnoreCap

1.3.6.1.4.1.9.9.826.1.79.8.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Cisco Firepower trig:Test:ignoreCap managed object property

cfprTrigTestIntId

1.3.6.1.4.1.9.9.826.1.79.8.1.9

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Test:intId managed object property

cfprTrigTestName

1.3.6.1.4.1.9.9.826.1.79.8.1.10

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Test:name managed object property

cfprTrigTestOperScheduler

1.3.6.1.4.1.9.9.826.1.79.8.1.11

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Test:operScheduler managed object property

cfprTrigTestOperState

1.3.6.1.4.1.9.9.826.1.79.8.1.12

CfprTrigTrigOperState0 = untriggered1 = evaluationPending2 = evaluated3 = waitingForUser4 = waitingForMaintWindow5 = applyPending6 = applied7 = waitingForDependency8 = none9 = expired10 = pending11 = active · Integer32

Cisco Firepower trig:Test:operState managed object property

cfprTrigTestPolicyLevel

1.3.6.1.4.1.9.9.826.1.79.8.1.13

Gauge32

Cisco Firepower trig:Test:policyLevel managed object property

cfprTrigTestPolicyOwner

1.3.6.1.4.1.9.9.826.1.79.8.1.14

CfprPolicyPolicyOwner0 = local1 = policy2 = pendingPolicy · Integer32

Cisco Firepower trig:Test:policyOwner managed object property

cfprTrigTestScheduler

1.3.6.1.4.1.9.9.826.1.79.8.1.15

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Test:scheduler managed object property

cfprTrigTriggeredTable

1.3.6.1.4.1.9.9.826.1.79.9

Index: cfprTrigTriggeredInstanceId

Cisco Firepower trig:Triggered managed object table

cfprTrigTriggeredInstanceId

1.3.6.1.4.1.9.9.826.1.79.9.1.1

CfprManagedObjectIdA unique identifier for this managed object. Objects in FPR Manager are stored in a Management Information Tree (MIT). The MIT is a repository of all Managed Object (MO) instances, indexed by their Distinguished Name (DN). The MIT somewhat resembles a file structure - going from main folder to the next lowest folder, and so on, until the full path to a MO is established. Every object in FPR Manager has two unique identifiers: 1) A distinguished name (DN). A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. The DN is used to identify objects in the XML API. 2) A CfprManagedObjectId, which is an integer uniquely identifying an object. The CfprManagedObjectId is used to identify objects and traverse tables when using the SNMP protocol. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1' and its CfprManagedObjectId set to '13203'. · Unsigned32 · hint d

Instance identifier of the managed object.

cfprTrigTriggeredDn

1.3.6.1.4.1.9.9.826.1.79.9.1.2

CfprManagedObjectDnAn immutable property of all Managed Objects (MO) that provides a fully qualified and unambiguous name for the MO. A DN provides a fully-qualified path from the top of the object tree. It is built as an ordered sequence of relative names separated by the '/' character. For example, an object representing a network adaptor on a blade might be identified with its DN set to 'sys/chassis-5/blade-2/adaptor-1'. · OCTET STRING

Cisco Firepower trig:Triggered:dn managed object property

cfprTrigTriggeredRn

1.3.6.1.4.1.9.9.826.1.79.9.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Triggered:rn managed object property

cfprTrigTriggeredJobCount

1.3.6.1.4.1.9.9.826.1.79.9.1.4

Gauge32

Cisco Firepower trig:Triggered:jobCount managed object property

cfprTrigTriggeredOperState

1.3.6.1.4.1.9.9.826.1.79.9.1.5

CfprTrigTriggeredState0 = pending1 = inProgress2 = failed3 = triggered · Integer32

Cisco Firepower trig:Triggered:operState managed object property

cfprTrigTriggeredOrder

1.3.6.1.4.1.9.9.826.1.79.9.1.6

Gauge32

Cisco Firepower trig:Triggered:order managed object property

cfprTrigTriggeredTrDn

1.3.6.1.4.1.9.9.826.1.79.9.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

Cisco Firepower trig:Triggered:trDn managed object property

cfprTrigTriggeredTrId

1.3.6.1.4.1.9.9.826.1.79.9.1.8

Gauge32

Cisco Firepower trig:Triggered:trId managed object property