EZ5 MIB Catalog

CISCO-IETF-ATM2-PVCTRAP-MIB

1998-02-03

This MIB Module is a supplement to the ATM-MIB.

Download CISCO-IETF-ATM2-PVCTRAP-MIB.txt Open CISCO-IETF-ATM2-PVCTRAP-MIB.txt in a new tab

TABLES (2) · TRAPS (1)

Tables (2)

NameOID
atmInterfaceExtTableaugments atmInterfaceConfTable (ATM-MIB)1.3.6.1.4.1.9.10.29.1.14
atmCurrentlyFailingPVclTable1.3.6.1.4.1.9.10.29.1.21

Traps (1)

NameOID
atmIntfPvcFailuresTrap1.3.6.1.4.1.9.10.29.2.1.0.1

END OF TOC

Table details

atmInterfaceExtTable

1.3.6.1.4.1.9.10.29.1.14

augments atmInterfaceConfTable (ATM-MIB)

Index: ifIndex

This table contains ATM interface monitoring information not defined in the atmInterfaceConfTable from the ATM-MIB.

from IF-MIB

ifIndex

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

atmIntfPvcFailures

1.3.6.1.4.1.9.10.29.1.14.1.20

Counter32

The number of times the operational status of a PVCL on this interface has gone down.

atmIntfCurrentlyFailingPVcls

1.3.6.1.4.1.9.10.29.1.14.1.22

Gauge32

The current number of VCLs on this interface for which there is an active row in the atmVclTable having an atmVclConnKind value of `pvc' and an atmVclOperStatus with a value other than `up'.

atmIntfPvcFailuresTrapEnable

1.3.6.1.4.1.9.10.29.1.14.1.23

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Allows the generation of traps in response to PVCL failures on this interface.

atmIntfPvcNotificationInterval

1.3.6.1.4.1.9.10.29.1.14.1.24

INTEGER (1..3600) · Integer32 · seconds

The minimum interval between the sending of cIntfPvcFailuresTrap notifications for this interface.

atmPreviouslyFailedPVclInterval

1.3.6.1.4.1.9.10.29.1.14.1.25

INTEGER (0..3600) · Integer32 · seconds

The interval for storing the failed time in atmPreviouslyFailedPVclTimeStamp

atmCurrentlyFailingPVclTable

1.3.6.1.4.1.9.10.29.1.21

Index: ifIndex · atmVclVpi · atmVclVci

A table indicating all VCLs for which there is an active row in the atmVclTable having an atmVclConnKind value of `pvc' and an atmVclOperStatus with a value other than `up'.

from IF-MIB

ifIndex

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

from ATM-MIB

atmVclVpi

AtmVpIdentifierThe VPI value for a VPL or VCL. The value VPI=0 is only allowed for a VCL. For ATM UNIs supporting VPCs the VPI value ranges from 0 to 255. The VPI value 0 is supported for ATM UNIs conforming to the ATM Forum UNI 4.0 Annex 8 (Virtual UNIs) specification. For ATM UNIs supporting VCCs the VPI value ranges from 0 to 255. For ATM NNIs the VPI value ranges from 0 to 4095. The maximum VPI value cannot exceed the value allowable by atmInterfaceMaxVpiBits defined in ATM-MIB. (0..4095) · Integer32

The VPI value of the VCL.

atmVclVci

AtmVcIdentifierThe VCI value for a VCL. The maximum VCI value cannot exceed the value allowable by atmInterfaceMaxVciBits defined in ATM-MIB. (0..65535) · Integer32

The VCI value of the VCL.

atmCurrentlyFailingPVclTimeStamp

1.3.6.1.4.1.9.10.29.1.21.1.1

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The time at which this PVCL began to fail.

atmPreviouslyFailedPVclTimeStamp

1.3.6.1.4.1.9.10.29.1.21.1.2

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The time at which this PVCL began to fail during the PVC Notification interval.

Trap details

atmIntfPvcFailuresTrap

1.3.6.1.4.1.9.10.29.2.1.0.1

A notification indicating that one or more PVCLs on this interface has failed since the last cIntfPvcFailuresTrap was sent. If this trap has not been sent for the last cIntfPvcNotificationInterval, then it will be sent on the next increment of cIntfPvcFailures.

ifIndex

1.3.6.1.2.1.2.2.1.1

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

atmIntfPvcFailures

1.3.6.1.4.1.9.10.29.1.14.1.20

Counter32

The number of times the operational status of a PVCL on this interface has gone down.

atmIntfCurrentlyFailingPVcls

1.3.6.1.4.1.9.10.29.1.14.1.22

Gauge32

The current number of VCLs on this interface for which there is an active row in the atmVclTable having an atmVclConnKind value of `pvc' and an atmVclOperStatus with a value other than `up'.

↑ To TOC