clemEnabled
1.3.6.1.4.1.9.9.426.1.1.1
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
Specifies whether the Link Error Monitor Feature is enabled on the device or not.
2004-11-19
The MIB module for managing Link Error Monitoring Feature on devices. Link Error Monitoring Feature provides a mechanism to monitor a certain set of link error counters on an interface and take certain actions when the increase in the error counters between two consecutive samplings exceeds the configurable thresholds consecutively for a certain number of times.
Download CISCO-LINK-ERROR-MONITOR-MIB.txt Open CISCO-LINK-ERROR-MONITOR-MIB.txt in a new tab
SCALARS (5) · TABLES (2) · TRAPS (2)
| Name | OID |
|---|---|
| clemThresholdTable | 1.3.6.1.4.1.9.9.426.1.1.5 |
| clemIfCounterTable | 1.3.6.1.4.1.9.9.426.1.2.1 |
| Name | OID |
|---|---|
| clemLowThresholdExceeded | 1.3.6.1.4.1.9.9.426.0.1 |
| clemHighThresholdExceeded | 1.3.6.1.4.1.9.9.426.0.2 |
END OF TOC
1.3.6.1.4.1.9.9.426.1.1.1
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
Specifies whether the Link Error Monitor Feature is enabled on the device or not.
1.3.6.1.4.1.9.9.426.1.1.2
Unsigned32 · seconds
Specifies the sampling interval to sample the interfaces' monitored link error counters.
1.3.6.1.4.1.9.9.426.1.1.3
Unsigned32
Specifies the consecutive number of times with error counter increase over thresholds between two consecutive samplings before corresponding notifications can be sent and actions can be taken on an interface.
1.3.6.1.4.1.9.9.426.1.1.4
INTEGER1 = errdisable2 = failover · Integer32
Specifies the action to be taken on an interface when the increase in an error counter on that interface between two consecutive sampling exceeds the corresponding clemThresholdHigh for consecutive number of times as specified by clemSamplingTimes. errdisable -- the interface is disabled by forcing its link down. failover -- when the interface is a member of a channel and it is the only operational member in the channel, then no operation will be taken. Otherwise, disable the interface by forcing its link down, i.e., errdisable the interface.
1.3.6.1.4.1.9.9.426.1.1.6
BITS
Indicates whether the generation of a specified notification is enabled or not. If a bit corresponding to a notification is set to 1, then that notification can be generated. lowThresholdExcd -- the clemLowThresholdExceeded notification. highThresholdExcd -- the clemHighThresholdExceeded notification.
1.3.6.1.4.1.9.9.426.1.1.5
Index: clemThresholdCounterType
A table containing threshold configuration for the monitored link error counters.
1.3.6.1.4.1.9.9.426.1.1.5.1.1
ClemCounterType1 = rxcrc2 = txcrc3 = inerrorsThe link error counters on interfaces to be monitored by the Link Error Monitor feature. rxcrc - the counter on the number of received packets with CRC and alignment errors. txcrc - the counter on the number of transmitted packets with CRC errors. inerrors - the ifInErrors counter as defined in IF-MIB. · Integer32
Indicates the type of link error counter to be monitored.
1.3.6.1.4.1.9.9.426.1.1.5.1.2
Unsigned32
Specifies the low threshold for an error counter type. When the increase in this error counter type on an interface between two consecutive sampling exceeds the instance value of clemThresholdLow for this error counter type consecutively for clemSamplingTimes number of times, a clemLowThresholdExceeded notification on that interface will be sent.
1.3.6.1.4.1.9.9.426.1.1.5.1.3
Unsigned32
Specifies the high threshold for an error counter type. When the increase in this error counter type on an interface between two consecutive sampling exceeds the instance value of clemThresholdHigh for this error counter type consecutively for clemSamplingTimes number of times, a clemHighThresholdExceeded notification on that interface will be sent. And, the action specified by clemAction will be taken on that interface. The instance value of this clemThresholdHigh must be greater than the instance value of the clemThresholdLow of the same row.
1.3.6.1.4.1.9.9.426.1.2.1
Index: ifIndex · clemIfCounterType
A table containing interface-specific link error monitoring information for each error counter type monitored by the feature.
from IF-MIB
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
1.3.6.1.4.1.9.9.426.1.2.1.1.1
ClemCounterType1 = rxcrc2 = txcrc3 = inerrorsThe link error counters on interfaces to be monitored by the Link Error Monitor feature. rxcrc - the counter on the number of received packets with CRC and alignment errors. txcrc - the counter on the number of transmitted packets with CRC errors. inerrors - the ifInErrors counter as defined in IF-MIB. · Integer32
Indicates the type of link error counter to be monitored on an interface.
1.3.6.1.4.1.9.9.426.1.2.1.1.2
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
Specifies whether the sampling on the corresponding error counter type is enabled on an interface or not.
1.3.6.1.4.1.9.9.426.0.1
This notification will be sent when the increase in an error counter type on an interface between two consecutive sampling exceeds the error counter's clemThresholdLow consecutively for clemSamplingTimes number of times.
1.3.6.1.4.1.9.9.426.1.1.5.1.2
Unsigned32
Specifies the low threshold for an error counter type. When the increase in this error counter type on an interface between two consecutive sampling exceeds the instance value of clemThresholdLow for this error counter type consecutively for clemSamplingTimes number of times, a clemLowThresholdExceeded notification on that interface will be sent.
1.3.6.1.2.1.2.2.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
1.3.6.1.4.1.9.9.426.0.2
This notification will be sent when the increase in an error counter type on an interface between two consecutive sampling exceeds the error counter's clemThresholdHigh consecutively for clemSamplingTimes number of times.
1.3.6.1.4.1.9.9.426.1.1.5.1.3
Unsigned32
Specifies the high threshold for an error counter type. When the increase in this error counter type on an interface between two consecutive sampling exceeds the instance value of clemThresholdHigh for this error counter type consecutively for clemSamplingTimes number of times, a clemHighThresholdExceeded notification on that interface will be sent. And, the action specified by clemAction will be taken on that interface. The instance value of this clemThresholdHigh must be greater than the instance value of the clemThresholdLow of the same row.
1.3.6.1.2.1.2.2.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.