CISCO-MODULE-AUTO-SHUTDOWN-MIB

2008-03-12

The CISCO-MODULE-AUTO-SHUTDOWN-MIB is used to configure the module automatic shutdown feature. Modules will be reset by the system when they become faulty. The module auto shutdown feature will shutdown such faulty modules when the resets occur too often. Once the modules are shutdown by this feature, they will stay shutdown until the administrator manually brings them back up. This will prevent the system from constantly resetting the faulty modules. This MIB module also covers the system initiated action occuring on a module.

Download CISCO-MODULE-AUTO-SHUTDOWN-MIB.txt Open CISCO-MODULE-AUTO-SHUTDOWN-MIB.txt in a new tab

SCALARS (6) · TABLES (1) · TRAPS (2)

Scalars (6)

NameOID
cmasFrequency1.3.6.1.4.1.9.9.386.1.1.1
cmasPeriod1.3.6.1.4.1.9.9.386.1.1.2
cmasMIBEnableNotification1.3.6.1.4.1.9.9.386.1.2.1
cmasModuleSysActionNotifEnable1.3.6.1.4.1.9.9.386.1.2.2
cmasModuleSysAction1.3.6.1.4.1.9.9.386.1.4.1
cmasModuleSysActionReason1.3.6.1.4.1.9.9.386.1.4.2

Tables (1)

NameOID
cmasModuleTable1.3.6.1.4.1.9.9.386.1.3.1

Traps (2)

NameOID
cmasModuleAutoShutdown1.3.6.1.4.1.9.9.386.0.1
cmasModuleSysActionNotif1.3.6.1.4.1.9.9.386.0.2

END OF TOC

Scalar details

cmasFrequency

1.3.6.1.4.1.9.9.386.1.1.1

Unsigned32

This indicates the threshold of the number of times the system can reset a faulty module, within the period specified by 'cmasPeriod'. Once the number of these system initiated resets exceeds this threshold, the module auto shutdown feature will shut down the module.

cmasPeriod

1.3.6.1.4.1.9.9.386.1.1.2

Unsigned32 · minutes

This indicates the period of time over which the number of system initiated module resets is monitored. In order for the module to be automatically shutdown, the number of times the system must reset the module has to exceed cmasFreqency times, in a span of cmasPeriod.

cmasMIBEnableNotification

1.3.6.1.4.1.9.9.386.1.2.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object indicates whether the system produces the cmasModuleAutoShutdown notification.

cmasModuleSysActionNotifEnable

1.3.6.1.4.1.9.9.386.1.2.2

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object indicates whether the system produces the cmasModuleSysActionNotif notification.

cmasModuleSysAction

1.3.6.1.4.1.9.9.386.1.4.1

CiscoModuleAutoShutSysAction1 = other2 = reset3 = powerCycle4 = powerDownThe type of system initiated action. Valid values are: other(1): none of the below. reset(2): reset the module. powerCycle(3): power cycle the module. powerDown(4): power down the module. · Integer32

This object identifies the system initiated action which is applied to a module.

cmasModuleSysActionReason

1.3.6.1.4.1.9.9.386.1.4.2

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

This object identifies the reason of system initiated action which is applied to a module.

Table details

cmasModuleTable

1.3.6.1.4.1.9.9.386.1.3.1

Index: entPhysicalIndex

This table contains information regarding the module auto shutdown feature.

from ENTITY-MIB

entPhysicalIndex

PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d

The index for this entry.

cmasModuleEnable

1.3.6.1.4.1.9.9.386.1.3.1.1.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object enables or disables the auto shutdown feature on a module. When the object is true(1), auto shutdown is enabled for that module. The feature will start monitoring system initiated module resets, and initiate a shutdown operation on the module if the number of resets, cmasModuleNumResets, exceeds the cmasFrequency within the previous cmasPeriod of time. When the object is false(2), auto shutdown is disabled for that module.

cmasModuleNumResets

1.3.6.1.4.1.9.9.386.1.3.1.1.2

Gauge32

This indicates the number of system initiated module resets that have occurred. This does not include user initiated module resets.

cmasModuleLastResetReason

1.3.6.1.4.1.9.9.386.1.3.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

This object identifies the reason for the last module reset initiated by the system. This object will contain a zero-length string if no such resets have occurred.

cmasModuleLastResetTime

1.3.6.1.4.1.9.9.386.1.3.1.1.4

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

This object corresponds to the date and time when the last system initiated module reset occurred. This object will contain 0-1-1,00:00:00:0 if no system initiated resets have occurred.

Trap details

cmasModuleAutoShutdown

1.3.6.1.4.1.9.9.386.0.1

This notification is generated when the module auto shutdown feature shuts down a module.

entPhysicalName

1.3.6.1.2.1.47.1.1.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's 'console'. This might be a text name (e.g., 'console') or a simple component number (e.g., port or module number, such as '1'), depending on the physical component naming syntax of the device. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1.

entPhysicalModelName

1.3.6.1.2.1.47.1.1.1.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The vendor-specific model name identifier string associated with this physical component. The preferred value is the customer-visible part number, which may be printed on the component itself. If the model name string associated with the physical component is unknown to the agent, then this object will contain a zero-length string.

cmasModuleNumResets

1.3.6.1.4.1.9.9.386.1.3.1.1.2

Gauge32

This indicates the number of system initiated module resets that have occurred. This does not include user initiated module resets.

cmasModuleLastResetReason

1.3.6.1.4.1.9.9.386.1.3.1.1.3

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

This object identifies the reason for the last module reset initiated by the system. This object will contain a zero-length string if no such resets have occurred.

cmasModuleSysActionNotif

1.3.6.1.4.1.9.9.386.0.2

This notification is generated when a system initiated action occurs on a module.

entPhysicalName

1.3.6.1.2.1.47.1.1.1.1.7

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The textual name of the physical entity. The value of this object should be the name of the component as assigned by the local device and should be suitable for use in commands entered at the device's 'console'. This might be a text name (e.g., 'console') or a simple component number (e.g., port or module number, such as '1'), depending on the physical component naming syntax of the device. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. Note that the value of entPhysicalName for two physical entities will be the same in the event that the console interface does not distinguish between them, e.g., slot-1 and the card in slot-1.

entPhysicalModelName

1.3.6.1.2.1.47.1.1.1.1.13

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

The vendor-specific model name identifier string associated with this physical component. The preferred value is the customer-visible part number, which may be printed on the component itself. If the model name string associated with the physical component is unknown to the agent, then this object will contain a zero-length string.

cmasModuleSysAction

1.3.6.1.4.1.9.9.386.1.4.1

CiscoModuleAutoShutSysAction1 = other2 = reset3 = powerCycle4 = powerDownThe type of system initiated action. Valid values are: other(1): none of the below. reset(2): reset the module. powerCycle(3): power cycle the module. powerDown(4): power down the module. · Integer32

This object identifies the system initiated action which is applied to a module.

cmasModuleSysActionReason

1.3.6.1.4.1.9.9.386.1.4.2

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

This object identifies the reason of system initiated action which is applied to a module.