This MIB module is used to monitor optical parameters of a network element.This MIB deals with the operating parameters of the optical layer. The optical layer is a term that defines all the devices/systems that deal with the conversion of data in it's electrical form to optical form, transmission of the optical data, reception, and finally re-conversion to electrical signals.

Download CISCO-OPTICAL-MONITORING-MIB.txt Open CISCO-OPTICAL-MONITORING-MIB.txt in a new tab

TABLES (1)

Tables (1)

NameOID
comParametersTable1.3.6.1.4.1.9.10.83.1.1.1

END OF TOC

Table details

comParametersTable

1.3.6.1.4.1.9.10.83.1.1.1

Index: ifIndex

Reference: ITU recommendations G.783, G.784, G.953

This table lists the instrumented parameters of all interfaces on the network element whose optical parameters are to be monitored.

from IF-MIB

ifIndex

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

comTxBiasCurrent

1.3.6.1.4.1.9.10.83.1.1.1.1.1

Integer32 (0..100000) · milliamps

This holds the value of the laser diode forward bias current for the interface being instrumented, and is an indication of the Tx optical power.

comTxPowerSupported

1.3.6.1.4.1.9.10.83.1.1.1.1.2

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Boolean to indicate if the interface being instrumented supports comTxPower. comTxPowerSupported is set to true if the interface supports the comTxPower object, and set to false otherwise.

comTxPower

1.3.6.1.4.1.9.10.83.1.1.1.1.3

Integer32 (0..2147483647) · microWatts

This object holds the value of the transmitter optical power for the interface being instrumented. The optical is proportional to the laser diode current. This object makes sense only if comTxPowerSupported is true. All values must be converted to microWatts.

comTxLaserTempSupported

1.3.6.1.4.1.9.10.83.1.1.1.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Boolean to indicate if the interface being instrumented supports comTxLaserTemp. comTxLaserTempSupported is set to true if the interface supports the comTxLaserTemp object, and set to false otherwise.

comTxLaserTemp

1.3.6.1.4.1.9.10.83.1.1.1.1.5

Integer32 (-253..200) · Degree Centigrade

This object holds the value of the transmitter laser diode temperature for the interface being instrumented. This object indicates the health of the transmitter.

comRxPowerACDC

1.3.6.1.4.1.9.10.83.1.1.1.1.6

Integer32 (0..2147483647) · microWatts

This object holds the value of the total power (AC + DC) at the optical Rx of the interface. All values must be converted to microWatts.

comRxPowerACSupported

1.3.6.1.4.1.9.10.83.1.1.1.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

Boolean to indicate if comRxPowerAC is supported by the interface being instrumented. comRxPowerACSupported is set to true if the interface supports the comRxPowerAC object,and set to false otherwise.

comRxPowerAC

1.3.6.1.4.1.9.10.83.1.1.1.1.8

Integer32 (0..2147483647) · microWatts

This object holds the value of the AC power at the optical Receiver of the interface. Not all interfaces support this object.This object makes sense only if comRxPowerACSupported is true. All values must be converted to microWatts.