The systemGroup (see RFC 1907) provides a standard set of basic system information. This MIB module contains Cisco-defined extensions to the systemGroup.
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
The current local date and time for the system.
Setting this object is equivalent to setting an automated clock and calendar. The value of the object will track the date and time from the value set. Note that due to hardware limitations some systems may not be able to preserve such meaning across reboots of the system, as indicated by csyClockLostOnReboot.
A constant value of all zeros and length 8 indicates the system is not aware of the present date and time.
This object may be read-only on some systems.
csyClockLostOnReboot
1.3.6.1.4.1.9.9.131.1.1.2
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
Indication of whether the system can preserve knowledge of current date and time across a system reboot.
A value of 'true' indicates the clock must be reset from some external source each time the system reboots.
A value of 'false' indicates the system has the ability to keep time across reboots.
csyLocationCountry
1.3.6.1.4.1.9.9.131.1.2.1
CountryCodeRepresents a case-insensitive 2-letter country code taken from ISO-3166. Unrecognized countries are represented as empty string. SIZE (0 | 2) · OCTET STRING
The country where the system is physically located.
On some systems and for some technologies this value affects behavior, such as standards for communication. All such technologies should default to using the setting of this value, but may provide an override if necessary.
The default value of this object is 'US'. Systems destined for other countries may use a different default. Systems in which the value does not affect operation should default to a zero-length value.
csySummerTimeStatus
1.3.6.1.4.1.9.9.131.1.3.1
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
An indication of whether the summertime feature is enabled on this device. When this object is set to true, then csySummerTimeOffset, csySummerTimeRecurringStart and
csySummerTimeRecurringEnd objects are set
to default values provided by the system. When this object is set to false, then csySummerTimeOffset, csySummerTimeRecurringStart, csySummerTimeRecurringEnd objects are not instantiated and the summertime feature is disabled.
csySummerTimeOffset
1.3.6.1.4.1.9.9.131.1.3.2
INTEGER (1..1440) · Integer32 · Minutes
The value of this object indicates number of
minutes to add or to subtract during summertime.
This object is not instantiated when csySummerTimeStatus object is set to false.
csySummerTimeRecurringStart
1.3.6.1.4.1.9.9.131.1.3.3
OCTET STRING SIZE (6)
Indicates summertime starts at this time every year.
octets contents range
1 week 1..5,ff last = ff
2-3 day 1..7
where sunday = 1 saturday = 7
4 month 1..12
where january = 1 december = 12
5 hour 0..23
6 min 0..59
For example, the first Monday in Feb at 13:30pm should be given as 01 00 02 02 0e 1e For the last Tuesday in dec at 1:20am should be given as ff 00 03 0c 01 14 This object is not instantiated when csySummerTimeStatus object is set to false.
csySummerTimeRecurringEnd
1.3.6.1.4.1.9.9.131.1.3.4
OCTET STRING SIZE (6)
Indicates summertime ends at this time every year.
octets contents range
1 week 1..5,ff where ff = last
2-3 day 1..7
where sunday = 1 saturday = 7
4 month 1..12
where january = 1 december = 12
5 hour 0..23
6 min 0..59
For example, the third friday in February at 3:30am should be given as 03 00 06 02 03 1e
For the first Tuesday in May at 1:20am should
be given as 01 00 03 05 01 14 This object is not instantiated when csySummerTimeStatus object is set to false.
csyStandardTmZnGMTOffset
1.3.6.1.4.1.9.9.131.1.3.5
Integer32 (-720..720) · minutes
This object is used to set standard timezone offset from GMT
in minutes.
csySummerTmZnGMTOffset
1.3.6.1.4.1.9.9.131.1.3.6
Integer32 (-720..720) · minutes
This object is used to set summer timezone offset from GMT in
minutes.
csyScheduledResetTime
1.3.6.1.4.1.9.9.131.1.4.1
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
The scheduled date and time the switch will be reset at. The system will only take octet strings with length 8 for this object which indicates the local time of the switch. The maximum scheduled time is 24 days from the current system clock time.
Setting this object value to be before the current system clock time or beyond the maximum scheduled time limit will be rejected by the system. Setting the object to all-zero octet strings will cancel the previously scheduled reset time and then the system will have no pending scheduled reset time. Setting this object value to be any valid octet strings other than the above cases will override the previously scheduled reset time and cause the system to be reset at the newly specified time.
After the system has accepted the scheduled reset time, if the system clock is advanced ahead of the scheduled reset time, then reset will happen approximately 5 minutes after the current clock.
csyScheduledResetAction
1.3.6.1.4.1.9.9.131.1.4.2
INTEGER1 = reset2 = resetMinDown · Integer32
Writing reset(1) to this object perform the normal reset operation on the active supervisor module.
Writing resetMinDown(2) to this object resets the system with the minimal system down time at the scheduled time. The resetMinDown(2) is only supported in systems with redundant supervisors.
csyScheduledResetReason
1.3.6.1.4.1.9.9.131.1.4.3
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
Indicates the reason users input when issuing system's scheduled reset. After the system
is reset, this object value will be empty octet
string.
csySnmpAuthFail
1.3.6.1.4.1.9.9.131.1.5.1
Counter32
The total number of SNMP messages received by the SNMP engine that were not properly authenticated.
csySnmpAuthFailAddressType
1.3.6.1.4.1.9.9.131.1.5.2
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
The type of Internet address by which the last received SNMP message that is not properly authenticated.
The value of this object is irrelevant if the value of csySnmpAuthFail is zero.
csySnmpAuthFailAddress
1.3.6.1.4.1.9.9.131.1.5.3
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
The internet address of the SNMP entity which sent the last received SNMP message that is not properly authenticated.
The value of this object is irrelevant if the value of csySnmpAuthFail is zero.
csyNotificationsEnable
1.3.6.1.4.1.9.9.131.1.6.1
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
This object indicates whether the system produces the notifications defined by the ciscoSystemNotificationsGroup. A false value will prevent notifications from being generated by this system.
Trap details
ciscoSystemClockChanged
1.3.6.1.4.1.9.9.131.2.0.1
A clock changed notification is generated when the current local date and time for the system has been manually changed. The value of csyClockDateAndTime reflects new date and time.
csyClockDateAndTime
1.3.6.1.4.1.9.9.131.1.1.1
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
The current local date and time for the system.
Setting this object is equivalent to setting an automated clock and calendar. The value of the object will track the date and time from the value set. Note that due to hardware limitations some systems may not be able to preserve such meaning across reboots of the system, as indicated by csyClockLostOnReboot.
A constant value of all zeros and length 8 indicates the system is not aware of the present date and time.
This object may be read-only on some systems.