EZ5 MIB Catalog

CISCO-WIRELESS-EXP-MIB

2005-12-27

This is the MIB Module for the Cisco Wireless Radio Point to Point experimental components. Glossary The following terms are used in the MIB definitions below. Radio Card: The line card that provides the wireless communication features. Radio Link: The bi-directional wireless link that exists between two communicating radio cards. Radio PHY: Represents the transmission characteristics of the Radio Link. RF Unit: The Radio Frequency components and the associated antennas. Radio System: Radio card and RF unit(s). Cisco Wireless Radio Experimental MIB Organization The Cisco Wireless Radio Experimental MIB provides the following management groups : When the draft-ietf-entmib-v2-03.txt gets finalized the Radio Frequency Group will be moved into that MIB. When the CISCO-IMAGE-MIB.my gets updated to include the image capabilities, the Image Group will be migrated into that MIB. When the CISCO-LED-MIB.my becomes available and supports the functionality the LED group needs, the LED group will be migrated into that. o. Radio Frequency Resource Group This contains information about the Radio frequency transmission and reception resources available on the system. This group determines the portions of the radio spectrum at which the radio subsystem can operate. This group in conjunction with the radio PHY group determine the acutal spectrum that gets used for communications. o. Image Group This provides facilities to manage radio line card's firmware image file URL's in router's image repository. It also provides access to the image details. o. LED Group This group provides information about LEDs available on the line card. o. Duplexor Group This group provides information about the Duplexors installed in the RF resources.

Download CISCO-WIRELESS-EXP-MIB.txt Open CISCO-WIRELESS-EXP-MIB.txt in a new tab

TABLES (5)

Tables (5)

NameOID
cwrRfEntityTable1.3.6.1.4.1.9.10.52.1.1.1
cwrIntFreqEntityTable1.3.6.1.4.1.9.10.52.1.1.2
cwrImageTable1.3.6.1.4.1.9.10.52.1.2.1
cwrLedTable1.3.6.1.4.1.9.10.52.1.3.1
cwrDuplexorTable1.3.6.1.4.1.9.10.52.1.4.1

END OF TOC

Table details

cwrRfEntityTable

1.3.6.1.4.1.9.10.52.1.1.1

Index: ifIndex · cwrRfEntityIndex

This table contains information about the radio frequency resources available for use on the system.

from IF-MIB

ifIndex

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

cwrRfEntityIndex

1.3.6.1.4.1.9.10.52.1.1.1.1.1

Integer32 (1..2147483647)

This object represents the index of this entry in the cwrRfEntityTable.

cwrRfSwRevision

1.3.6.1.4.1.9.10.52.1.1.1.1.2

Unsigned32

This object represents the software revision number of controlling the RF subsystem.

cwrRfAssemblyPartNumberClass

1.3.6.1.4.1.9.10.52.1.1.1.1.3

Unsigned32

This object represents the assembly part number class of the RF subsystem.

cwrRfAssemblyPartNumberBase

1.3.6.1.4.1.9.10.52.1.1.1.1.4

Unsigned32

This object represents the assembly part number base of the RF subsystem.

cwrRfAssemblyPartNumberVersion

1.3.6.1.4.1.9.10.52.1.1.1.1.5

Unsigned32

This object represents the assembly part number version of the RF subsystem.

cwrRfBoardPartNumberClass

1.3.6.1.4.1.9.10.52.1.1.1.1.6

Unsigned32

This object represents the board part number class of the RF subsystem.

cwrRfBoardPartNumberBase

1.3.6.1.4.1.9.10.52.1.1.1.1.7

Unsigned32

This object represents the board part number base of the RF subsystem.

cwrRfBoardPartNumberVersion

1.3.6.1.4.1.9.10.52.1.1.1.1.8

Unsigned32

This object represents the board part number version of the RF subsystem.

cwrRfBoardRevision

1.3.6.1.4.1.9.10.52.1.1.1.1.9

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the board revision of the RF subsystem.

cwrRfSerialNumber

1.3.6.1.4.1.9.10.52.1.1.1.1.10

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the serial number of the RF subsystem.

cwrRfManfDate

1.3.6.1.4.1.9.10.52.1.1.1.1.11

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

This object represents the manufacturing date of the RF subsystem.

cwrRfVendorId

1.3.6.1.4.1.9.10.52.1.1.1.1.12

Integer32 (1..256)

This object represents the Radio frequency device vendor ID.

cwrRfDuplexorIndex

1.3.6.1.4.1.9.10.52.1.1.1.1.13

Integer32 (1..2147483647)

This object represents the index into cwrDuplexorTable. This index identifies the Duplexor associated with this RF resource.

cwrIntFreqEntityTable

1.3.6.1.4.1.9.10.52.1.1.2

Index: ifIndex

This table contains information about the intermediate frequency subsystem on the radio card.

from IF-MIB

ifIndex

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

cwrIfAssemblyPartNumberClass

1.3.6.1.4.1.9.10.52.1.1.2.1.1

Unsigned32

This object represents the assembly part number class of the IF subsystem.

cwrIfAssemblyPartNumberBase

1.3.6.1.4.1.9.10.52.1.1.2.1.2

Unsigned32

This object represents the assembly part number base of the IF subsystem.

cwrIfAssemblyPartNumberVersion

1.3.6.1.4.1.9.10.52.1.1.2.1.3

Unsigned32

This object represents the assembly part number version of the IF subsystem.

cwrIfBoardPartNumberClass

1.3.6.1.4.1.9.10.52.1.1.2.1.4

Unsigned32

This object represents the board part number class of the IF subsystem.

cwrIfBoardPartNumberBase

1.3.6.1.4.1.9.10.52.1.1.2.1.5

Unsigned32

This object represents the board part number base of the IF subsystem.

cwrIfBoardPartNumberVersion

1.3.6.1.4.1.9.10.52.1.1.2.1.6

Unsigned32

This object represents the board part number version of the IF subsystem.

cwrIfBoardRevision

1.3.6.1.4.1.9.10.52.1.1.2.1.7

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the board revision of the IF subsystem.

cwrIfSerialNumber

1.3.6.1.4.1.9.10.52.1.1.2.1.8

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the serial number of the IF subsystem.

cwrIfManfDate

1.3.6.1.4.1.9.10.52.1.1.2.1.9

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

This object represents the manufacturing date of the IF subsystem.

cwrIfVendorId

1.3.6.1.4.1.9.10.52.1.1.2.1.10

Integer32 (1..256)

This object represents the IF vendor ID.

cwrIfSwRevision

1.3.6.1.4.1.9.10.52.1.1.2.1.11

Unsigned32

This object represents the IF software revision.

cwrImageTable

1.3.6.1.4.1.9.10.52.1.2.1

Index: cwrImageIndex

This table provides facilities to manage the firmware images that the router will use to configure the radio line cards. When images need to be downloaded, the software will search this list starting from the first, for an image whose capabilities match the configuration specified in the cwrRadioBaseTable and the cwrRadioPhyTable and download that image to the appropriate hardware component. Insertion into the table at arbitrary points is not supported. Any new image URL added to this table will be inserted at index 1 only. Also note that an image gets downloaded to the hardware only when when a radio link is administratively enabled.

cwrImageIndex

1.3.6.1.4.1.9.10.52.1.2.1.1.1

Integer32 (1..2147483647)

This represents the one entry in this table. It also represents the search order. When images need to be downloaded to the hardware, the images are searched in the order of this index for an image that matches the hardware capabilities and uses it.

cwrImageNameUrl

1.3.6.1.4.1.9.10.52.1.2.1.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (1..255) · OCTET STRING · hint 255a

This object is the name of the image in the Universal Resource Locator (URL) format. This URL will be used to access the image when needed.

cwrImageState

1.3.6.1.4.1.9.10.52.1.2.1.1.3

INTEGER1 = imageInvalid2 = imageValid · Integer32

This represents the state of the image. image_invalid(1): If the image could not be accessed for any reason. image_valid(2) : Image accessible and available for use.

cwrImageSize

1.3.6.1.4.1.9.10.52.1.2.1.1.4

Unsigned32

This represents the size of the image in bytes.

cwrImageChipClass

1.3.6.1.4.1.9.10.52.1.2.1.1.5

Unsigned32

This represents the class of chips onto which this image may be loaded.

cwrImageChipType

1.3.6.1.4.1.9.10.52.1.2.1.1.6

Unsigned32

This represents the download method to use.

cwrImageCapability1

1.3.6.1.4.1.9.10.52.1.2.1.1.7

Unsigned32

This represents a bitmask. The bit mask identifies the capabilities of this image. See also cwrImageCapability2.

cwrImageCapability2

1.3.6.1.4.1.9.10.52.1.2.1.1.8

Unsigned32

This represents a bitmask. The bit mask identifies the capabilities of this image in addition to cwrImageCapability1.

cwrImageVersion

1.3.6.1.4.1.9.10.52.1.2.1.1.9

Unsigned32

This represents the version number of this image.

cwrImageTag

1.3.6.1.4.1.9.10.52.1.2.1.1.10

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (1..255) · OCTET STRING · hint 255a

This object is the tag string associated with the image. Normally used to trace the source code used to generate this image.

cwrImageOp

1.3.6.1.4.1.9.10.52.1.2.1.1.11

INTEGER0 = nop1 = add2 = delete3 = move · Integer32

This object represents the operation to be performed on the identified image. nop(0) - This value will be returned when this object is read. add(1) - Will add the image URL, as the first entry in the image table. delete(2) - Will delete the specified ULR from the image table. move(3) - Will make the image specified by the URL the first entry in the imageTable.

cwrLedTable

1.3.6.1.4.1.9.10.52.1.3.1

Index: entPhysicalIndex · cwrLedIndex

Entity (Light emitting diode) LED information. For each LED on the entity, an entry will exist in this table, describing the location and current status of that LED.

from ENTITY-MIB

entPhysicalIndex

PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d

The index for this entry.

cwrLedIndex

1.3.6.1.4.1.9.10.52.1.3.1.1.1

INTEGER (1..16) · Integer32

For a given entPhysicalIndex, this index value uniquely identifies an entry in the cwrLedTable.

cwrLedName

1.3.6.1.4.1.9.10.52.1.3.1.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The label of the LED on the physical entity or a textual description to identify the usage of the LED.

cwrLedVerticalPosition

1.3.6.1.4.1.9.10.52.1.3.1.1.3

Integer32 (1..16)

The position of the LED in the entity. It is counted from top to bottom.

cwrLedHorizontalPosition

1.3.6.1.4.1.9.10.52.1.3.1.1.4

Integer32 (1..16)

The position of the LED in the entity. It is counted from from left to right.

cwrLedMode

1.3.6.1.4.1.9.10.52.1.3.1.1.5

INTEGER1 = automatic2 = latched3 = forceOff4 = forceSolidGreen5 = forceSolidYellow6 = forceBlinkGreen7 = forceBlinkYellow8 = forceBlinkBoth · Integer32

This objects specifies the desired mode of LED updates. automatic(1) and latched(2) are settings used by the software to determine how the LED should be updated. The others are for diagnostic purposes. The LED will be turned on or off as specified by the other (3-8) settings. The modes mean the following: automatic(1): The system updates the LED according to the default settings for that entity. latched(2): Once the LED is turned on, user has to turn it off. This applies only to alarm LEDs. forceOff(3): Force the LED off. forceSolidGreen(4): Force the LED to be solid green in on state. forceSolidYellow(5):Force the LED to be solid Yellow in on state forceBlinkGreen(6): Force the LED to blink in Green. forceBlinkYellow(7):Force the LED to blink in Yellow. forceBlinkBoth(8): Force the LED to blink Yellow and Green alternatively.

cwrLedCurrentColor

1.3.6.1.4.1.9.10.52.1.3.1.1.6

INTEGER1 = green2 = yellow3 = blinkGreen4 = blinkYellow5 = blinkGreenYellow6 = off · Integer32

Indicates the current color of the LED.

cwrDuplexorTable

1.3.6.1.4.1.9.10.52.1.4.1

Index: ifIndex · cwrDuplexorIndex

This table contains information about the Duplexors available for use on the system.

from IF-MIB

ifIndex

InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d

A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.

cwrDuplexorIndex

1.3.6.1.4.1.9.10.52.1.4.1.1.1

Integer32 (1..2147483647)

This object represents the index of this entry in the cwrDuplexorTable.

cwrDuplexorCiscoPartNumber

1.3.6.1.4.1.9.10.52.1.4.1.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the Cisco part number for this Duplexor.

cwrDuplexorLoPassbandRange

1.3.6.1.4.1.9.10.52.1.4.1.1.3

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the low frequency range that this Duplexor will pass through without any attenuation. All low frequencies outside this range will be attenuated to a level such that an RF resource that uses this Duplexor will be unable to transmit or receive those frequencies.

cwrDuplexorHiPassbandRange

1.3.6.1.4.1.9.10.52.1.4.1.1.4

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object represents the high frequency range that this Duplexor will pass through without any attenuation. All high frequencies outside this range will be attenuated to a level such that an RF resource that uses this Duplexor will be unable to transmit or receive those frequencies.

cwrDuplexorReceivePassband

1.3.6.1.4.1.9.10.52.1.4.1.1.5

INTEGER1 = loPassband2 = hiPassband · Integer32

This object indicates which of the two passbands are being used to receive transmissions. The RF Resource can receive on either of the duplexor passbands. loPassband(1) - The RF Resource is receiving on a frequency within the range identified by cwrDuplexorLoPassbandRange. hiPassband(2) - The RF Resource is receiving on a frequency within the range identified by cwrDuplexorHiPassbandRange.

cwrDuplexorCLEICode

1.3.6.1.4.1.9.10.52.1.4.1.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The CLEI code for this Duplexor.

cwrDuplexorVendorName

1.3.6.1.4.1.9.10.52.1.4.1.1.7

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The Vendor Name for this Duplexor.

cwrDuplexorSerialNumber

1.3.6.1.4.1.9.10.52.1.4.1.1.8

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The Serial number of this Duplexor.

↑ To TOC