The maximum number of concurrent active ping requests that are allowed within an agent implementation. A value of 0 for this object implies that there is no limit for the number of concurrent active requests in effect.
Table details
pingCtlTable
1.3.6.1.2.1.80.1.2
Index: pingCtlOwnerIndex · pingCtlTestName
Defines the ping Control Table for providing, via SNMP, the capability of performing ping operations at a remote host. The results of these operations are stored in the pingResultsTable and the pingProbeHistoryTable.
pingCtlOwnerIndex
1.3.6.1.2.1.80.1.2.1.1
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..32) · OCTET STRING · hint 255t
To facilitate the provisioning of access control by a security administrator using the View-Based Access Control Model (RFC 2575, VACM) for tables in which multiple users may need to independently create or modify entries, the initial index is used as an 'owner index'. Such an initial index has a syntax of SnmpAdminString, and can thus be trivially mapped to a securityName or groupName as defined in VACM, in accordance with a security policy.
When used in conjunction with such a security policy all entries in the table belonging to a particular user (or group) will have the same value for this initial index. For a given user's entries in a particular table, the object identifiers for the information in these entries will have the same subidentifiers (except for the 'column' subidentifier) up to the end of the encoded owner index. To configure VACM to permit access to this portion of the table, one would create vacmViewTreeFamilyTable entries with the value of vacmViewTreeFamilySubtree including the owner index portion, and vacmViewTreeFamilyMask 'wildcarding' the column subidentifier. More elaborate configurations are possible.
pingCtlTestName
1.3.6.1.2.1.80.1.2.1.2
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..32) · OCTET STRING · hint 255t
The name of the ping test. This is locally unique, within the scope of an pingCtlOwnerIndex.
pingCtlTargetAddressType
1.3.6.1.2.1.80.1.2.1.3
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
Specifies the type of host address to be used at a remote host for performing a ping operation.
pingCtlTargetAddress
1.3.6.1.2.1.80.1.2.1.4
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
Specifies the host address to be used at a remote host for performing a ping operation. The host address type is determined by the object value of corresponding pingCtlTargetAddressType. A value for this object MUST be set prior to transitioning its corresponding pingCtlEntry to active(1) via pingCtlRowStatus.
pingCtlDataSize
1.3.6.1.2.1.80.1.2.1.5
Unsigned32 (0..65507) · octets
Specifies the size of the data portion to be transmitted in a ping operation in octets. A ping request is usually an ICMP message encoded into an IP packet. An IP packet has a maximum size of 65535 octets. Subtracting the size of the ICMP or UDP header (both 8 octets) and the size of the IP header (20 octets) yields a maximum size of 65507 octets.
pingCtlTimeOut
1.3.6.1.2.1.80.1.2.1.6
Unsigned32 (1..60) · seconds
Specifies the time-out value, in seconds, for a remote ping operation.
pingCtlProbeCount
1.3.6.1.2.1.80.1.2.1.7
Unsigned32 (1..15) · probes
Specifies the number of times to perform a ping operation at a remote host.
pingCtlAdminStatus
1.3.6.1.2.1.80.1.2.1.8
INTEGER1 = enabled2 = disabled · Integer32
Reflects the desired state that a pingCtlEntry should be in:
enabled(1) - Attempt to activate the test as defined by
this pingCtlEntry. disabled(2) - Deactivate the test as defined by this pingCtlEntry.
Refer to the corresponding pingResultsOperStatus to determine the operational state of the test defined by this entry.
pingCtlDataFill
1.3.6.1.2.1.80.1.2.1.9
OCTET STRING SIZE (0..1024)
The content of this object is used together with the corresponding pingCtlDataSize value to determine how to fill the data portion of a probe packet. The option of selecting a data fill pattern can be useful when links are compressed or have data pattern sensitivities. The contents of pingCtlDataFill should be repeated in a ping packet when the size of the data portion of the ping packet is greater than the size of pingCtlDataFill.
pingCtlFrequency
1.3.6.1.2.1.80.1.2.1.10
Unsigned32 · seconds
The number of seconds to wait before repeating a ping test as defined by the value of the various objects in the corresponding row.
A single ping test consists of a series of ping probes. The number of probes is determined by the value of the corresponding pingCtlProbeCount object. After a single test completes the number of seconds as defined by the value of pingCtlFrequency MUST elapse before the next ping test is started.
A value of 0 for this object implies that the test as defined by the corresponding entry will not be repeated.
pingCtlMaxRows
1.3.6.1.2.1.80.1.2.1.11
Unsigned32 · rows
The maximum number of entries allowed in the pingProbeHistoryTable. An implementation of this MIB will remove the oldest entry in the pingProbeHistoryTable to allow the addition of an new entry once the number of rows in the pingProbeHistoryTable reaches this value.
Old entries are not removed when a new test is started. Entries are added to the pingProbeHistoryTable until pingCtlMaxRows is reached before entries begin to be removed.
A value of 0 for this object disables creation of pingProbeHistoryTable entries.
pingCtlStorageType
1.3.6.1.2.1.80.1.2.1.12
StorageType1 = other2 = volatile3 = nonVolatile4 = permanent5 = readOnlyDescribes the memory realization of a conceptual row. A row which is volatile(2) is lost upon reboot. A row which is either nonVolatile(3), permanent(4) or readOnly(5), is backed up by stable storage. A row which is permanent(4) can be changed but not deleted. A row which is readOnly(5) cannot be changed nor deleted.
If the value of an object with this syntax is either permanent(4) or readOnly(5), it cannot be written. Conversely, if the value is either other(1), volatile(2) or nonVolatile(3), it cannot be modified to be permanent(4) or readOnly(5). (All illegal modifications result in a 'wrongValue' error.)
Every usage of this textual convention is required to specify the columnar objects which a permanent(4) row must at a minimum allow to be writable. · Integer32
The storage type for this conceptual row. Conceptual rows having the value 'permanent' need not allow write-access to any columnar objects in the row.
pingCtlTrapGeneration
1.3.6.1.2.1.80.1.2.1.13
BITS
The value of this object determines when and if to generate a notification for this entry:
probeFailure(0) - Generate a pingProbeFailed
notification subject to the value of pingCtlTrapProbeFailureFilter. The object pingCtlTrapProbeFailureFilter can be used to specify the number of successive probe failures that are required before a pingProbeFailed notification can be generated.
testFailure(1) - Generate a pingTestFailed
notification. In this instance the object pingCtlTrapTestFailureFilter can be used to determine the number of probe failures that signal when a test fails. testCompletion(2) - Generate a pingTestCompleted notification.
The value of this object defaults to zero, indicating that none of the above options have been selected.
pingCtlTrapProbeFailureFilter
1.3.6.1.2.1.80.1.2.1.14
Unsigned32 (0..15)
The value of this object is used to determine when to generate a pingProbeFailed NOTIFICATION.
Setting pingCtlTrapGeneration to probeFailure(0) implies that a pingProbeFailed NOTIFICATION is generated only when the number of successive probe failures as indicated by the value of pingCtlTrapPrbefailureFilter fail within a given ping test.
pingCtlTrapTestFailureFilter
1.3.6.1.2.1.80.1.2.1.15
Unsigned32 (0..15)
The value of this object is used to determine when to generate a pingTestFailed NOTIFICATION.
Setting pingCtlTrapGeneration to testFailure(1) implies that a pingTestFailed NOTIFICATION is generated only when the number of ping failures within a test exceed the value of pingCtlTrapTestFailureFilter.
pingCtlType
1.3.6.1.2.1.80.1.2.1.16
OBJECT IDENTIFIER
The value of this object is used to either report or select the implementation method to be used for calculating a ping response time. The value of this object MAY be selected from pingImplementationTypeDomains.
Additional implementation types SHOULD be allocated as required by implementers of the DISMAN-PING-MIB under their enterprise specific registration point and not beneath pingImplementationTypeDomains.
pingCtlDescr
1.3.6.1.2.1.80.1.2.1.17
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t
The purpose of this object is to provide a descriptive name of the remote ping test.
pingCtlSourceAddressType
1.3.6.1.2.1.80.1.2.1.18
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
Specifies the type of the source address, pingCtlSourceAddress, to be used at a remote host when performing a ping operation.
pingCtlSourceAddress
1.3.6.1.2.1.80.1.2.1.19
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
Use the specified IP address (which must be given in numeric form, not as a hostname) as the source address in outgoing probe packets. On hosts with more than one IP address, this option can be used to force the source address to be something other than the primary IP address of the interface the probe packet is sent on. If the IP address is not one of this machine's interface addresses, an error is returned and nothing is sent. A zero length octet string value for this object disables source address specification.
The address type (InetAddressType) that relates to this object is specified by the corresponding value of pingCtlSourceAddressType.
pingCtlIfIndex
1.3.6.1.2.1.80.1.2.1.20
InterfaceIndexOrZeroThis textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits the additional value of zero. the value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where interface was unknown, or when none or all interfaces need to be referenced. (0..2147483647) · Integer32 · hint d
Setting this object to an interface's ifIndex prior to starting a remote ping operation directs the ping probes to be transmitted over the specified interface. A value of zero for this object means that this option is not enabled.
pingCtlByPassRouteTable
1.3.6.1.2.1.80.1.2.1.21
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
The purpose of this object is to optionally enable bypassing the route table. If enabled, the remote host will bypass the normal routing tables and send directly to a host on an attached network. If the host is not on a directly-attached network, an error is returned. This option can be used to perform the ping operation to a local host through an interface that has no route defined (e.g., after the interface was dropped by routed).
pingCtlDSField
1.3.6.1.2.1.80.1.2.1.22
Unsigned32 (0..255)
Reference: Refer to RFC 2474 for the definition of the Differentiated Services Field and to RFC 1812 Section 5.3.2 for Type of Service (TOS).
Specifies the value to store in the Differentiated Services (DS) Field in the IP packet used to encapsulate the ping probe. The DS Field is defined as the Type of Service (TOS) octet in a IPv4 header or as the Traffic Class octet in a IPv6 header.
The value of this object must be a decimal integer in the range from 0 to 255. This option can be used to determine what effect an explicit DS Field setting has on a ping response. Not all values are legal or meaningful. A value of 0 means that the function represented by this option is not supported. DS Field usage is often not supported by IP implementations and not all values are supported. Refer to RFC 2474 for guidance on usage of this field.
pingCtlRowStatus
1.3.6.1.2.1.80.1.2.1.23
RowStatus1 = active2 = notInService3 = notReady4 = createAndGo5 = createAndWait6 = destroyThe RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of [2].)
The status column has six defined values:
- `active', which indicates that the conceptual row is available for use by the managed device;
- `notInService', which indicates that the conceptual row exists in the agent, but is unavailable for use by the managed device (see NOTE below); 'notInService' has no implication regarding the internal consistency of the row, availability of resources, or consistency with the current state of the managed device;
- `notReady', which indicates that the conceptual row exists in the agent, but is missing information necessary in order to be available for use by the managed device (i.e., one or more required columns in the conceptual row have not been instanciated);
- `createAndGo', which is supplied by a management station wishing to create a new instance of a conceptual row and to have its status automatically set to active, making it available for use by the managed device;
- `createAndWait', which is supplied by a management station wishing to create a new instance of a conceptual row (but not make it available for use by the managed device); and, - `destroy', which is supplied by a management station wishing to delete all of the instances associated with an existing conceptual row.
Whereas five of the six values (all except `notReady') may be specified in a management protocol set operation, only three values will be returned in response to a management
protocol retrieval operation: `notReady', `notInService' or
`active'. That is, when queried, an existing conceptual row
has only three states: it is either available for use by
the managed device (the status column has value `active'); it is not available for use by the managed device, though the agent has sufficient information to attempt to make it so (the status column has value `notInService'); or, it is not available for use by the managed device, and an attempt to make it so would fail because the agent has insufficient information (the state column has value `notReady').
NOTE WELL
This textual convention may be used for a MIB table, irrespective of whether the values of that table's conceptual rows are able to be modified while it is active, or whether its conceptual rows must be taken out of service in order to be modified. That is, it is the responsibility of the DESCRIPTION clause of the status column to specify whether the status column must not be `active' in order for the value of some other column of the same conceptual row to be modified. If such a specification is made, affected columns may be changed by an SNMP set PDU if the RowStatus would not be equal to `active' either immediately before or after processing the PDU. In other words, if the PDU also contained a varbind that would change the RowStatus value, the column in question may be changed if the RowStatus was not equal to `active' as the PDU was received, or if the varbind sets the status to a value other than 'active'.
Also note that whenever any elements of a row exist, the RowStatus column must also exist.
To summarize the effect of having a conceptual row with a status column having a SYNTAX clause value of RowStatus, consider the following state diagram:
STATE +--------------+-----------+-------------+-------------
| A | B | C | D
| |status col.|status column|
|status column | is | is |status column
ACTION |does not exist| notReady | notInService| is active
--------------+--------------+-----------+-------------+-------------
set status |noError ->D|inconsist- |inconsistent-|inconsistent-
column to | or | entValue| Value| Value
createAndGo |inconsistent- | | |
| Value| | |
--------------+--------------+-----------+-------------+-------------
set status |noError see 1|inconsist- |inconsistent-|inconsistent-
column to | or | entValue| Value| Value
createAndWait |wrongValue | | |
--------------+--------------+-----------+-------------+-------------
set status |inconsistent- |inconsist- |noError |noError
column to | Value| entValue| |
active | | | |
| | or | |
| | | |
| |see 2 ->D|see 8 ->D| ->D
--------------+--------------+-----------+-------------+-------------
set status |inconsistent- |inconsist- |noError |noError ->C
column to | Value| entValue| |
notInService | | | |
| | or | | or
| | | |
| |see 3 ->C| ->C|see 6
--------------+--------------+-----------+-------------+-------------
set status |noError |noError |noError |noError ->A
column to | | | | or
destroy | ->A| ->A| ->A|see 7
--------------+--------------+-----------+-------------+-------------
set any other |see 4 |noError |noError |see 5
column to some| | | |
value | | see 1| ->C| ->D
--------------+--------------+-----------+-------------+-------------
(1) goto B or C, depending on information available to the agent.
(2) if other variable bindings included in the same PDU, provide values for all columns which are missing but required, and all columns have acceptable values, then return noError and goto D.
(3) if other variable bindings included in the same PDU, provide legal values for all columns which are missing but required, then return noError and goto C.
(4) at the discretion of the agent, the return value may be either:
inconsistentName: because the agent does not choose to
create such an instance when the corresponding RowStatus instance does not exist, or
inconsistentValue: if the supplied value is
inconsistent with the state of some other MIB object's value, or
noError: because the agent chooses to create the instance.
If noError is returned, then the instance of the status column must also be created, and the new state is B or C, depending on the information available to the agent. If inconsistentName or inconsistentValue is returned, the row remains in state A.
(5) depending on the MIB definition for the column/table, either noError or inconsistentValue may be returned.
(6) the return value can indicate one of the following errors:
wrongValue: because the agent does not support notInService (e.g., an agent which does not support createAndWait), or
inconsistentValue: because the agent is unable to take the row out of service at this time, perhaps because it is in use and cannot be de-activated.
(7) the return value can indicate the following error:
inconsistentValue: because the agent is unable to remove the row at this time, perhaps because it is in use and cannot be de-activated.
(8) the transition to D can fail, e.g., if the values of the conceptual row are inconsistent, then the error code would be inconsistentValue.
NOTE: Other processing of (this and other varbinds of) the set request may result in a response other than noError being returned, e.g., wrongValue, noCreation, etc.
Conceptual Row Creation
There are four potential interactions when creating a
conceptual row: selecting an instance-identifier which is
not in use; creating the conceptual row; initializing any objects for which the agent does not supply a default; and, making the conceptual row available for use by the managed device.
Interaction 1: Selecting an Instance-Identifier
The algorithm used to select an instance-identifier varies for each conceptual row. In some cases, the instance- identifier is semantically significant, e.g., the destination address of a route, and a management station selects the instance-identifier according to the semantics.
In other cases, the instance-identifier is used solely to distinguish conceptual rows, and a management station without specific knowledge of the conceptual row might examine the instances present in order to determine an unused instance-identifier. (This approach may be used, but it is often highly sub-optimal; however, it is also a questionable practice for a naive management station to attempt conceptual row creation.)
Alternately, the MIB module which defines the conceptual row might provide one or more objects which provide assistance in determining an unused instance-identifier. For example, if the conceptual row is indexed by an integer-value, then an object having an integer-valued SYNTAX clause might be defined for such a purpose, allowing a management station to issue a management protocol retrieval operation. In order to avoid unnecessary collisions between competing management stations, `adjacent' retrievals of this object should be different.
Finally, the management station could select a pseudo-random number to use as the index. In the event that this index
was already in use and an inconsistentValue was returned in response to the management protocol set operation, the management station should simply select a new pseudo-random number and retry the operation.
A MIB designer should choose between the two latter algorithms based on the size of the table (and therefore the efficiency of each algorithm). For tables in which a large number of entries are expected, it is recommended that a MIB object be defined that returns an acceptable index for creation. For tables with small numbers of entries, it is recommended that the latter pseudo-random index mechanism be used.
Interaction 2: Creating the Conceptual Row
Once an unused instance-identifier has been selected, the management station determines if it wishes to create and activate the conceptual row in one transaction or in a negotiated set of interactions.
Interaction 2a: Creating and Activating the Conceptual Row
The management station must first determine the column requirements, i.e., it must determine those columns for which it must or must not provide values. Depending on the complexity of the table and the management station's knowledge of the agent's capabilities, this determination can be made locally by the management station. Alternately, the management station issues a management protocol get operation to examine all columns in the conceptual row that it wishes to create. In response, for each column, there are three possible outcomes:
- a value is returned, indicating that some other management station has already created this conceptual row. We return to interaction 1.
- the exception `noSuchInstance' is returned, indicating that the agent implements the object-type associated with this column, and that this column in at least one conceptual row would be accessible in the MIB view used by the retrieval were it to exist. For those columns to which the agent provides read-create access, the `noSuchInstance' exception tells the management station that it should supply a value for this column when the conceptual row is to be created.
- the exception `noSuchObject' is returned, indicating that the agent does not implement the object-type associated with this column or that there is no conceptual row for which this column would be accessible in the MIB view used by the retrieval. As such, the management station can not issue any management protocol set operations to create an instance of this column.
Once the column requirements have been determined, a management protocol set operation is accordingly issued. This operation also sets the new instance of the status column to `createAndGo'.
When the agent processes the set operation, it verifies that it has sufficient information to make the conceptual row available for use by the managed device. The information
available to the agent is provided by two sources: the
management protocol set operation which creates the conceptual row, and, implementation-specific defaults supplied by the agent (note that an agent must provide implementation-specific defaults for at least those objects which it implements as read-only). If there is sufficient information available, then the conceptual row is created, a `noError' response is returned, the status column is set to `active', and no further interactions are necessary (i.e., interactions 3 and 4 are skipped). If there is insufficient information, then the conceptual row is not created, and the set operation fails with an error of `inconsistentValue'. On this error, the management station can issue a management protocol retrieval operation to determine if this was because it failed to specify a value for a required column, or, because the selected instance of the status column already existed. In the latter case, we return to interaction 1. In the former case, the management station can re-issue the set operation with the additional information, or begin interaction 2 again using `createAndWait' in order to negotiate creation of the conceptual row.
NOTE WELL
Regardless of the method used to determine the column requirements, it is possible that the management station might deem a column necessary when, in fact, the agent will not allow that particular columnar instance to be created or written. In this case, the management protocol set operation will fail with an error such as `noCreation' or `notWritable'. In this case, the management station decides whether it needs to be able to set a value for that particular columnar instance. If not, the management station re-issues the management protocol set operation, but without setting a value for that particular columnar instance; otherwise, the management station aborts the row creation algorithm.
Interaction 2b: Negotiating the Creation of the Conceptual Row
The management station issues a management protocol set operation which sets the desired instance of the status column to `createAndWait'. If the agent is unwilling to process a request of this sort, the set operation fails with an error of `wrongValue'. (As a consequence, such an agent must be prepared to accept a single management protocol set operation, i.e., interaction 2a above, containing all of the
columns indicated by its column requirements.) Otherwise,
the conceptual row is created, a `noError' response is returned, and the status column is immediately set to either `notInService' or `notReady', depending on whether it has sufficient information to (attempt to) make the conceptual row available for use by the managed device. If there is sufficient information available, then the status column is set to `notInService'; otherwise, if there is insufficient information, then the status column is set to `notReady'. Regardless, we proceed to interaction 3.
Interaction 3: Initializing non-defaulted Objects
The management station must now determine the column requirements. It issues a management protocol get operation to examine all columns in the created conceptual row. In the response, for each column, there are three possible outcomes:
- a value is returned, indicating that the agent implements the object-type associated with this column and had sufficient information to provide a value. For those columns to which the agent provides read-create access (and for which the agent allows their values to be changed after their creation), a value return tells the management station that it may issue additional management protocol set operations, if it desires, in order to change the value associated with this column.
- the exception `noSuchInstance' is returned, indicating that the agent implements the object-type associated with this column, and that this column in at least one conceptual row would be accessible in the MIB view used by the retrieval were it to exist. However, the agent does not have sufficient information to provide a value, and until a value is provided, the conceptual row may not be made available for use by the managed device. For those columns to which the agent provides read-create access, the `noSuchInstance' exception tells the management station that it must issue additional management protocol set operations, in order to provide a value associated with this column.
- the exception `noSuchObject' is returned, indicating that the agent does not implement the object-type associated with this column or that there is no conceptual row for which this column would be accessible in the MIB view used by the retrieval. As such, the management station can not issue any management protocol set operations to create an instance of this column.
If the value associated with the status column is `notReady', then the management station must first deal with all `noSuchInstance' columns, if any. Having done so, the value of the status column becomes `notInService', and we proceed to interaction 4.
Interaction 4: Making the Conceptual Row Available
Once the management station is satisfied with the values associated with the columns of the conceptual row, it issues a management protocol set operation to set the status column to `active'. If the agent has sufficient information to make the conceptual row available for use by the managed device, the management protocol set operation succeeds (a `noError' response is returned). Otherwise, the management protocol set operation fails with an error of `inconsistentValue'.
NOTE WELL
A conceptual row having a status column with value `notInService' or `notReady' is unavailable to the managed device. As such, it is possible for the managed device to create its own instances during the time between the management protocol set operation which sets the status column to `createAndWait' and the management protocol set operation which sets the status column to `active'. In this case, when the management protocol set operation is issued to set the status column to `active', the values held in the agent supersede those used by the managed device.
If the management station is prevented from setting the status column to `active' (e.g., due to management station or network failure) the conceptual row will be left in the `notInService' or `notReady' state, consuming resources indefinitely. The agent must detect conceptual rows that have been in either state for an abnormally long period of time and remove them. It is the responsibility of the DESCRIPTION clause of the status column to indicate what an abnormally long period of time would be. This period of time should be long enough to allow for human response time (including `think time') between the creation of the conceptual row and the setting of the status to `active'. In the absence of such information in the DESCRIPTION clause, it is suggested that this period be approximately 5 minutes in length. This removal action applies not only to newly-created rows, but also to previously active rows which are set to, and left in, the notInService state for a prolonged period exceeding that which is considered normal for such a conceptual row.
Conceptual Row Suspension
When a conceptual row is `active', the management station may issue a management protocol set operation which sets the instance of the status column to `notInService'. If the agent is unwilling to do so, the set operation fails with an error of `wrongValue' or `inconsistentValue'. Otherwise, the conceptual row is taken out of service, and a `noError' response is returned. It is the responsibility of the DESCRIPTION clause of the status column to indicate under what circumstances the status column should be taken out of service (e.g., in order for the value of some other column of the same conceptual row to be modified).
Conceptual Row Deletion
For deletion of conceptual rows, a management protocol set operation is issued which sets the instance of the status column to `destroy'. This request may be made regardless of the current value of the status column (e.g., it is possible to delete conceptual rows which are either `notReady',
`notInService' or `active'.) If the operation succeeds,
then all instances associated with the conceptual row are immediately removed. · Integer32
Reference: See definition of RowStatus in RFC 2579, 'Textual Conventions for SMIv2.'
This object allows entries to be created and deleted in the pingCtlTable. Deletion of an entry in this table results in all corresponding (same pingCtlOwnerIndex and pingCtlTestName index values) pingResultsTable and pingProbeHistoryTable entries being deleted.
A value MUST be specified for pingCtlTargetAddress prior to a transition to active(1) state being accepted.
Activation of a remote ping operation is controlled via pingCtlAdminStatus and not by changing this object's value to active(1).
Transitions in and out of active(1) state are not allowed while an entry's pingResultsOperStatus is active(1) with the exception that deletion of an entry in this table by setting its RowStatus object to destroy(6) will stop an active ping operation.
The operational state of a ping operation can be determined by examination of its pingResultsOperStatus object.
pingResultsTable
1.3.6.1.2.1.80.1.3
Index: pingCtlOwnerIndex · pingCtlTestName
Defines the Ping Results Table for providing the capability of performing ping operations at a remote host. The results of these operations are stored in the pingResultsTable and the pingPastProbeTable.
An entry is added to the pingResultsTable when an pingCtlEntry is started by successful transition of its pingCtlAdminStatus object to enabled(1). An entry is removed from the pingResultsTable when its corresponding pingCtlEntry is deleted.
pingResultsOperStatus
1.3.6.1.2.1.80.1.3.1.1
INTEGER1 = enabled2 = disabled · Integer32
Reflects the operational state of a pingCtlEntry:
enabled(1) - Test is active.
disabled(2) - Test has stopped.
pingResultsIpTargetAddressType
1.3.6.1.2.1.80.1.3.1.2
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
This objects indicates the type of address stored in the corresponding pingResultsIpTargetAddress object.
pingResultsIpTargetAddress
1.3.6.1.2.1.80.1.3.1.3
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
This objects reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero length octet string when a DNS name is not specified or when a specified DNS name fails to resolve.
pingResultsMinRtt
1.3.6.1.2.1.80.1.3.1.4
Unsigned32 · milliseconds
The minimum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsMaxRtt
1.3.6.1.2.1.80.1.3.1.5
Unsigned32 · milliseconds
The maximum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsAverageRtt
1.3.6.1.2.1.80.1.3.1.6
Unsigned32 · milliseconds
The current average ping round-trip-time (RTT).
pingResultsProbeResponses
1.3.6.1.2.1.80.1.3.1.7
Unsigned32 · responses
Number of responses received for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probe responses have been received.
pingResultsSentProbes
1.3.6.1.2.1.80.1.3.1.8
Unsigned32 · probes
The value of this object reflects the number of probes sent for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probes have been sent.
pingResultsRttSumOfSquares
1.3.6.1.2.1.80.1.3.1.9
Unsigned32 · milliseconds
This object contains the sum of the squares for all ping responses received. Its purpose is to enable standard deviation calculation. The value of this object MUST be reported as 0 when no ping responses have been received.
pingResultsLastGoodProbe
1.3.6.1.2.1.80.1.3.1.10
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Date and time when the last response was received for a probe.
Defines a table for storing the results of a ping operation. Entries in this table are limited by the value of the corresponding pingCtlMaxRows object.
An entry in this table is created when the result of a ping probe is determined. The initial 2 instance identifier index values identify the pingCtlEntry that a probe result (pingProbeHistoryEntry) belongs to. An entry is removed from this table when its corresponding pingCtlEntry is deleted.
An implementation of this MIB will remove the oldest entry in the pingProbeHistoryTable to allow the addition of an new entry once the number of rows in the pingProbeHistoryTable reaches the value specified by pingCtlMaxRows.
pingProbeHistoryIndex
1.3.6.1.2.1.80.1.4.1.1
Unsigned32 (1..4294967295)
An entry in this table is created when the result of a ping probe is determined. The initial 2 instance identifier index values identify the pingCtlEntry that a probe result (pingProbeHistoryEntry) belongs to.
An implementation MUST start assigning pingProbeHistoryIndex values at 1 and wrap after exceeding the maximum possible value as defined by the limit of this object ('ffffffff'h).
pingProbeHistoryResponse
1.3.6.1.2.1.80.1.4.1.2
Unsigned32 · milliseconds
The amount of time measured in milliseconds from when a probe was sent to when its response was received or when it timed out. The value of this object is reported as 0 when it is not possible to transmit a probe.
pingProbeHistoryStatus
1.3.6.1.2.1.80.1.4.1.3
OperationResponseStatus1 = responseReceived2 = unknown3 = internalError4 = requestTimedOut5 = unknownDestinationAddress6 = noRouteToTarget7 = interfaceInactiveToTarget8 = arpFailure9 = maxConcurrentLimitReached10 = unableToResolveDnsName11 = invalidHostAddressUsed to report the result of an operation:
responseReceived(1) - Operation completes successfully. unknown(2) - Operation failed due to unknown error. internalError(3) - An implementation detected an error in its own processing that caused an operation to fail. requestTimedOut(4) - Operation failed to receive a valid reply within the time limit imposed on it. unknownDestinationAddress(5) - Invalid destination address. noRouteToTarget(6) - Could not find a route to target. interfaceInactiveToTarget(7) - The interface to be used in sending a probe is inactive without an alternate route existing. arpFailure(8) - Unable to resolve a target address to a media specific address. maxConcurrentLimitReached(9) - The maximum number of concurrent active operations would have been exceeded if the corresponding operation was allowed. unableToResolveDnsName(10) - The DNS name specified was unable to be mapped to an IP address. invalidHostAddress(11) - The IP address for a host has been determined to be invalid. Examples of this are broadcast or multicast addresses. · Integer32
The result of a particular probe done by a remote host.
pingProbeHistoryLastRC
1.3.6.1.2.1.80.1.4.1.4
Integer32
The last implementation method specific reply code received. If the ICMP Echo capability is being used then a successful probe ends when an ICMP response is received that contains the code ICMP_ECHOREPLY(0). The ICMP responses are defined normally in the ip_icmp include file.
pingProbeHistoryTime
1.3.6.1.2.1.80.1.4.1.5
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Timestamp for when this probe result was determined.
Trap details
pingProbeFailed
1.3.6.1.2.1.80.0.1
Generated when a probe failure is detected when the corresponding pingCtlTrapGeneration object is set to probeFailure(0) subject to the value of pingCtlTrapProbeFailureFilter. The object pingCtlTrapProbeFailureFilter can be used to specify the number of successive probe failures that are required before this notification can be generated.
pingCtlTargetAddressType
1.3.6.1.2.1.80.1.2.1.3
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
Specifies the type of host address to be used at a remote host for performing a ping operation.
pingCtlTargetAddress
1.3.6.1.2.1.80.1.2.1.4
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
Specifies the host address to be used at a remote host for performing a ping operation. The host address type is determined by the object value of corresponding pingCtlTargetAddressType. A value for this object MUST be set prior to transitioning its corresponding pingCtlEntry to active(1) via pingCtlRowStatus.
pingResultsOperStatus
1.3.6.1.2.1.80.1.3.1.1
INTEGER1 = enabled2 = disabled · Integer32
Reflects the operational state of a pingCtlEntry:
enabled(1) - Test is active.
disabled(2) - Test has stopped.
pingResultsIpTargetAddressType
1.3.6.1.2.1.80.1.3.1.2
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
This objects indicates the type of address stored in the corresponding pingResultsIpTargetAddress object.
pingResultsIpTargetAddress
1.3.6.1.2.1.80.1.3.1.3
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
This objects reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero length octet string when a DNS name is not specified or when a specified DNS name fails to resolve.
pingResultsMinRtt
1.3.6.1.2.1.80.1.3.1.4
Unsigned32 · milliseconds
The minimum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsMaxRtt
1.3.6.1.2.1.80.1.3.1.5
Unsigned32 · milliseconds
The maximum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsAverageRtt
1.3.6.1.2.1.80.1.3.1.6
Unsigned32 · milliseconds
The current average ping round-trip-time (RTT).
pingResultsProbeResponses
1.3.6.1.2.1.80.1.3.1.7
Unsigned32 · responses
Number of responses received for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probe responses have been received.
pingResultsSentProbes
1.3.6.1.2.1.80.1.3.1.8
Unsigned32 · probes
The value of this object reflects the number of probes sent for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probes have been sent.
pingResultsRttSumOfSquares
1.3.6.1.2.1.80.1.3.1.9
Unsigned32 · milliseconds
This object contains the sum of the squares for all ping responses received. Its purpose is to enable standard deviation calculation. The value of this object MUST be reported as 0 when no ping responses have been received.
pingResultsLastGoodProbe
1.3.6.1.2.1.80.1.3.1.10
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Date and time when the last response was received for a probe.
pingTestFailed
1.3.6.1.2.1.80.0.2
Generated when a ping test is determined to have failed when the corresponding pingCtlTrapGeneration object is set to testFailure(1). In this instance pingCtlTrapTestFailureFilter should specify the number of probes in a test required to have failed in order to consider the test as failed.
pingCtlTargetAddressType
1.3.6.1.2.1.80.1.2.1.3
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
Specifies the type of host address to be used at a remote host for performing a ping operation.
pingCtlTargetAddress
1.3.6.1.2.1.80.1.2.1.4
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
Specifies the host address to be used at a remote host for performing a ping operation. The host address type is determined by the object value of corresponding pingCtlTargetAddressType. A value for this object MUST be set prior to transitioning its corresponding pingCtlEntry to active(1) via pingCtlRowStatus.
pingResultsOperStatus
1.3.6.1.2.1.80.1.3.1.1
INTEGER1 = enabled2 = disabled · Integer32
Reflects the operational state of a pingCtlEntry:
enabled(1) - Test is active.
disabled(2) - Test has stopped.
pingResultsIpTargetAddressType
1.3.6.1.2.1.80.1.3.1.2
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
This objects indicates the type of address stored in the corresponding pingResultsIpTargetAddress object.
pingResultsIpTargetAddress
1.3.6.1.2.1.80.1.3.1.3
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
This objects reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero length octet string when a DNS name is not specified or when a specified DNS name fails to resolve.
pingResultsMinRtt
1.3.6.1.2.1.80.1.3.1.4
Unsigned32 · milliseconds
The minimum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsMaxRtt
1.3.6.1.2.1.80.1.3.1.5
Unsigned32 · milliseconds
The maximum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsAverageRtt
1.3.6.1.2.1.80.1.3.1.6
Unsigned32 · milliseconds
The current average ping round-trip-time (RTT).
pingResultsProbeResponses
1.3.6.1.2.1.80.1.3.1.7
Unsigned32 · responses
Number of responses received for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probe responses have been received.
pingResultsSentProbes
1.3.6.1.2.1.80.1.3.1.8
Unsigned32 · probes
The value of this object reflects the number of probes sent for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probes have been sent.
pingResultsRttSumOfSquares
1.3.6.1.2.1.80.1.3.1.9
Unsigned32 · milliseconds
This object contains the sum of the squares for all ping responses received. Its purpose is to enable standard deviation calculation. The value of this object MUST be reported as 0 when no ping responses have been received.
pingResultsLastGoodProbe
1.3.6.1.2.1.80.1.3.1.10
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Date and time when the last response was received for a probe.
pingTestCompleted
1.3.6.1.2.1.80.0.3
Generated at the completion of a ping test when the corresponding pingCtlTrapGeneration object is set to testCompletion(4).
pingCtlTargetAddressType
1.3.6.1.2.1.80.1.2.1.3
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
Specifies the type of host address to be used at a remote host for performing a ping operation.
pingCtlTargetAddress
1.3.6.1.2.1.80.1.2.1.4
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
Specifies the host address to be used at a remote host for performing a ping operation. The host address type is determined by the object value of corresponding pingCtlTargetAddressType. A value for this object MUST be set prior to transitioning its corresponding pingCtlEntry to active(1) via pingCtlRowStatus.
pingResultsOperStatus
1.3.6.1.2.1.80.1.3.1.1
INTEGER1 = enabled2 = disabled · Integer32
Reflects the operational state of a pingCtlEntry:
enabled(1) - Test is active.
disabled(2) - Test has stopped.
pingResultsIpTargetAddressType
1.3.6.1.2.1.80.1.3.1.2
InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address.
unknown(0) An unknown address type. This value MUST
be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below.
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
ipv4z(3) A non-global IPv4 address including a zone
index as defined by the InetAddressIPv4z textual convention.
ipv6z(4) A non-global IPv6 address including a zone
index as defined by the InetAddressIPv6z textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention.
Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType.
To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation.
Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32
This objects indicates the type of address stored in the corresponding pingResultsIpTargetAddress object.
pingResultsIpTargetAddress
1.3.6.1.2.1.80.1.3.1.3
InetAddressDenotes a generic Internet address.
An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row.
The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error.
When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING
This objects reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero length octet string when a DNS name is not specified or when a specified DNS name fails to resolve.
pingResultsMinRtt
1.3.6.1.2.1.80.1.3.1.4
Unsigned32 · milliseconds
The minimum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsMaxRtt
1.3.6.1.2.1.80.1.3.1.5
Unsigned32 · milliseconds
The maximum ping round-trip-time (RTT) received. A value of 0 for this object implies that no RTT has been received.
pingResultsAverageRtt
1.3.6.1.2.1.80.1.3.1.6
Unsigned32 · milliseconds
The current average ping round-trip-time (RTT).
pingResultsProbeResponses
1.3.6.1.2.1.80.1.3.1.7
Unsigned32 · responses
Number of responses received for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probe responses have been received.
pingResultsSentProbes
1.3.6.1.2.1.80.1.3.1.8
Unsigned32 · probes
The value of this object reflects the number of probes sent for the corresponding pingCtlEntry and pingResultsEntry. The value of this object MUST be reported as 0 when no probes have been sent.
pingResultsRttSumOfSquares
1.3.6.1.2.1.80.1.3.1.9
Unsigned32 · milliseconds
This object contains the sum of the squares for all ping responses received. Its purpose is to enable standard deviation calculation. The value of this object MUST be reported as 0 when no ping responses have been received.
pingResultsLastGoodProbe
1.3.6.1.2.1.80.1.3.1.10
DateAndTimeA date-time specification.
field octets contents range
----- ------ -------- -----
1 1-2 year* 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minutes 0..59
6 7 seconds 0..60
(use 60 for leap-second)
7 8 deci-seconds 0..9
8 9 direction from UTC '+' / '-'
9 10 hours from UTC* 0..13
10 11 minutes from UTC 0..59
* Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13
For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as:
1992-5-26,13:30:15.0,-4:0
Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d
Date and time when the last response was received for a probe.