esStackMyBoxId
1.3.6.1.4.1.171.17.9.1.1.2
Integer32 (1..255)
This object indicates the box ID of the device.
2019-07-25
Download DLINKES-STACK-MIB.txt Open DLINKES-STACK-MIB.txt in a new tab
This MIB module defines objects for stacking lite feature.
SCALARS (17) · TABLES (2) · TRAPS (1)
| Name | OID |
|---|---|
| esStackUnitInfoTable | 1.3.6.1.4.1.171.17.9.1.1.13 |
| esStackUnitStackPortTable | 1.3.6.1.4.1.171.17.9.1.1.14 |
| Name | OID |
|---|---|
| esStackTPChangeNotification | 1.3.6.1.4.1.171.17.9.0.4 |
END OF TOC
1.3.6.1.4.1.171.17.9.1.1.2
Integer32 (1..255)
This object indicates the box ID of the device.
1.3.6.1.4.1.171.17.9.1.1.3
Integer32 (1..255)
This object indicates the master box ID.
1.3.6.1.4.1.171.17.9.1.1.4
Integer32 (0..255)
This object indicates the backup box ID, 0 is no backup box selected.
1.3.6.1.4.1.171.17.9.1.1.5
Integer32 (1..255)
This object indicates the current number of devices in the stacking system. The number of devices(boxes) can be stacked is restricted by max box count and max stack cost.
1.3.6.1.4.1.171.17.9.1.1.6
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
This object indicates whether the administrative stacking mode has been enabled or not. The new setting will not take effect until the next reboot.
1.3.6.1.4.1.171.17.9.1.1.8
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
This object indicates whether the sending of stacking related traps is enabled or not.
1.3.6.1.4.1.171.17.9.1.1.9
INTEGER1 = twoPortSfp2 = fourPortSfp3 = twoPort10BaseT4 = fourPortHybrid · Integer32
This object indicates the stacking port bandwidth. twoPortSfp - two SFP+ ports are used for stacking fourPortSFP - four SFP+ ports are used for stacking twoPort10BaseT - two 10-BaseT ports are used for stacking fourPortHybrid - two SFP+ and two 10-BaseT ports are used for stacking The stacking port bandwidth setting of a switch device must be set before the switch unit can be chained with other switch devices. The setting will be saved on local switch unit if the user saves the configuration. The change of stacking port bandwidth will not take effect until the next reboot.
1.3.6.1.4.1.171.17.9.1.1.10
INTEGER1 = synchronized2 = stale3 = nobackupbox · Integer32
Indicates whether the running configuration on the backup box includes all changes made on the master box. synchronized: The running configuration on the backup box is the same as on the master box. stale: The running configuration has not yet been copied to the backup box or has been synchronized, but it is out of date. nobackupbox: No backup unit has been elected.
1.3.6.1.4.1.171.17.9.1.1.11
Unsigned32 · seconds
Age of the running configuration on the backup unit. The time since the running configuration was last synchronized to the backup unit.
1.3.6.1.4.1.171.17.9.1.1.12
Unsigned32 · seconds
The number of seconds until the running configuration will be synchronized to the backup unit. The special value of 0 represents the running configuration synchronization is unnecessary and the running configuration on the backup box is synchronized.
1.3.6.1.4.1.171.17.9.1.1.15
Integer32 (1..255)
This object indicates the maximum number of devices allowed in the stacking system. The number of devices(boxes) can be stacked is restricted by max box count and max stack cost.
1.3.6.1.4.1.171.17.9.1.1.16
Integer32 (1..255)
This object indicates the maximum cost allowed in the stacking system. The devices(boxes) that can be stacked is limited by the device number and the cost.
1.3.6.1.4.1.171.17.9.1.1.17
Integer32 (1..255)
This object indicates the current cost in the stacking system. The number of devices(boxes) can be stacked is restricted by max box count and max stack cost.
1.3.6.1.4.1.171.17.9.1.1.18
DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
This object indicates the Stack technology information.
1.3.6.1.4.1.171.17.9.1.1.19
INTEGER1 = standAlone2 = duplexChain3 = duplexRing · Integer32
This object indicates the state of the stacking topology.
1.3.6.1.4.1.171.17.9.1.2.1
Integer32 (1..255)
This object indicates box ID of the notification.
1.3.6.1.4.1.171.17.9.1.2.2
INTEGER1 = chain2 = ring · Integer32
This object indicates the current stacking topology of the notification.
1.3.6.1.4.1.171.17.9.1.1.13
Index: esStackInfoBoxId
This table displays the information of the devices in the stacking system. When stacking mode is not effectively enabled, there is no entry in this table.
1.3.6.1.4.1.171.17.9.1.1.13.1.1
Integer32 (1..255)
This object indicates box ID of the entry.
1.3.6.1.4.1.171.17.9.1.1.13.1.2
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
The state of existence of the unit.
1.3.6.1.4.1.171.17.9.1.1.13.1.3
INTEGER1 = unknown3 = standAlone4 = master5 = slave6 = backupmaster · Integer32
The stacking role of the unit.
1.3.6.1.4.1.171.17.9.1.1.13.1.4
Integer32 (0..255)
Allows setting the unit number associated with this unit. This number must be less than the value supported. Setting this object to a non-zero value will initate unit renumbering. The switch will be reset to perform unit renumbering and the configuration of switch interfaces will be cleared. If the unit being renumbered is the manager of the stack, then all the switches in the stack will be reset to perform Manager unit renumbering and the configuration of Manager switch interfaces will be cleared.
1.3.6.1.4.1.171.17.9.1.1.13.1.5
DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a
This object indicates the module name of the device.
1.3.6.1.4.1.171.17.9.1.1.13.1.6
Integer32 (0..15)
Indicates the configured preference value assigned to the unit. The preference value indicates how likely this unit is to be chosen as the management unit. A value of 0 indicates an unassigned preference. 1 - 15 indicates a specified preference and the higher number means a higher priority.
1.3.6.1.4.1.171.17.9.1.1.13.1.7
MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:
The MAC address of the device.
1.3.6.1.4.1.171.17.9.1.1.13.1.8
DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
A textual string containing the PROM version of the stacking device.
1.3.6.1.4.1.171.17.9.1.1.13.1.9
DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
A textual string containing the firmware version of the stacking device.
1.3.6.1.4.1.171.17.9.1.1.13.1.10
DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
A textual string containing the hardware version of the stacking device.
1.3.6.1.4.1.171.17.9.1.1.13.1.14
INTEGER0 = unknown1 = ok2 = unsupported3 = codeMismatch4 = notPresent5 = codeUpdate · Integer32
The unit status of this stacking box.
1.3.6.1.4.1.171.17.9.1.1.13.1.15
Integer32 (0..15)
The unit cost.
1.3.6.1.4.1.171.17.9.1.1.13.1.16
Integer32 (0..65535)
The start front port number of this stacking box.
1.3.6.1.4.1.171.17.9.1.1.13.1.17
Integer32 (0..65535)
The total front ports of this unit.
1.3.6.1.4.1.171.17.9.1.1.14
Index: esStackStackPortIndex
This table displays contains information for all stack ports present in the stacking system. When stacking mode is not effectively enabled, there is no entry in this table.
1.3.6.1.4.1.171.17.9.1.1.14.1.1
Unsigned32
An arbitrary index used to reference Stack Ports in the table.
1.3.6.1.4.1.171.17.9.1.1.14.1.2
Integer32 (1..255)
The Box Index this Stack Port is physically located on.
1.3.6.1.4.1.171.17.9.1.1.14.1.3
DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
The name of the Stack Port for this instance.
1.3.6.1.4.1.171.17.9.1.1.14.1.4
INTEGER1 = up2 = down · Integer32
Link status of the Stack Port.
1.3.6.1.4.1.171.17.9.1.1.14.1.5
Gauge32
Speed of the Stack Port measured in Gb/s.
1.3.6.1.4.1.171.17.9.1.1.14.1.6
Integer32 (1..255)
The Neighbor Box Index this Stack Port is physically connected to. When the link status of this Stack Port is down, box ID 0 is always returned.
1.3.6.1.4.1.171.17.9.0.4
The stacking topology change notification.
1.3.6.1.4.1.171.17.9.1.2.2
INTEGER1 = chain2 = ring · Integer32
This object indicates the current stacking topology of the notification.
1.3.6.1.4.1.171.17.9.1.2.1
Integer32 (1..255)
This object indicates box ID of the notification.
1.3.6.1.4.1.171.17.9.1.1.13.1.7
MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:
The MAC address of the device.