The is the MIB module that describes DS3 and E3 interfaces objects.
Copyright (c) The Internet Society (2004). This version of this MIB module is part of RFC 3896 </rfcs/rfc3896.html>; see the RFC itself for full legal notices.
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of ifStackTable.
Previously, this object was the identifier of a DS3/E3 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS3/E3 interface, it should have the same value as ifIndex. Otherwise, number the dsx3LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g., network side) with odd numbers.
dsx3IfIndex
1.3.6.1.2.1.10.30.5.1.2
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213 </rfcs/rfc1213.html>).
dsx3TimeElapsed
1.3.6.1.2.1.10.30.5.1.3
INTEGER (0..899) · Integer32
The number of seconds that have elapsed since the
beginning of the near end current error- measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
dsx3ValidIntervals
1.3.6.1.2.1.10.30.5.1.4
INTEGER (0..96) · Integer32
The number of previous near end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available.
Reference: American National Standard for telecommunications - digital hierarchy - formats specification, ANSI T1.107- 1988. ANSI T1.107a-1990. American National Standard for telecommunications - digital hierarchy - electrical interfaces, ANSI T1.102- 1987. CCITT - Digital Multiplex Equipment Operating at the Third Order Bit Rate of 34 368 Kbit/s and the Forth Order Bit Rate of 139 264 Kbit/s and Using Positive Justification, G.751 European Telecommunications Standards Institute -- ETS '34M' -- Metropolitan Area Network Physical Convergence Layer Procedure for 34.368 Megabits per Second, T/NA(91)18, May 1991.
This variable indicates the variety of DS3 C-bit or E3 application implementing this interface. The type of interface affects the interpretation of the usage and error statistics. The rate of DS3 is 44.736 Mbps and E3 is 34.368 Mbps. The dsx3ClearChannel value means that the C-bits are not used except for sending/receiving AIS. The values, in sequence, describe:
TITLE: SPECIFICATION:
dsx3M23 ANSI T1.107-1988
dsx3SYNTRAN ANSI T1.107-1988
dsx3CbitParity ANSI T1.107a-1990
dsx3ClearChannel ANSI T1.102-1987
e3Framed CCITT G.751
e3Plcp ETSI T/NA(91)18
dsx3M13 ANSI T1.107a-1990.
This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx3B3ZS and e3HDB3 refer to the use of specified patterns of normal bits and bipolar violations which are used to replace sequences of zero bits of a specified length.
This variable indicates what type of code is being sent across the DS3/E3 interface by the device. (These are optional for E3 interfaces.) Setting this variable causes the interface to begin sending the code requested. The values mean:
dsx3SendNoCode sending looped or normal data
dsx3SendLineCode sending a request for a line loopback
dsx3SendPayloadCode sending a request for a payload loopback (i.e., all DS1/E1s in a DS3/E3 frame)
dsx3SendResetCode sending a loopback deactivation request
dsx3SendDS1LoopCode requesting to loopback a particular DS1/E1 within a DS3/E3 frame. The DS1/E1 is indicated in dsx3Ds1ForRemoteLoop.
dsx3SendTestPattern sending a test pattern.
dsx3CircuitIdentifier
1.3.6.1.2.1.10.30.5.1.8
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
Reference: ITU-T M.1400
This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting.
This variable represents the desired loopback configuration of the DS3/E3 interface. The values mean:
dsx3NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value.
dsx3PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function.
dsx3LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out.
dsx3OtherLoop Loopbacks that are not defined here.
dsx3InwardLoop The sent signal at this interface is looped back through the device.
dsx3DualLoop Both dsx1LineLoop and dsx1InwardLoop will be active simultaneously.
dsx3LineStatus
1.3.6.1.2.1.10.30.5.1.10
INTEGER (1..4095) · Integer32
This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm must be set if and only if no other flag is set.
If the dsx3loopbackState bit is set, the loopback in effect can be determined from the dsx3loopbackConfig object. The various bit positions are:
1 dsx3NoAlarm No alarm present
2 dsx3RcvRAIFailure Receiving Yellow/Remote
Alarm Indication
4 dsx3XmitRAIAlarm Transmitting Yellow/Remote
Alarm Indication
8 dsx3RcvAIS Receiving AIS failure state
16 dsx3XmitAIS Transmitting AIS
32 dsx3LOF Receiving LOF failure state
64 dsx3LOS Receiving LOS failure state
128 dsx3LoopbackState Looping the received signal
256 dsx3RcvTestCode Receiving a Test Pattern
512 dsx3OtherFailure any line status not defined
here
1024 dsx3UnavailSigState Near End in Unavailable
Signal State
2048 dsx3NetEquipOOS Carrier Equipment Out of
Service
The source of Transmit Clock.
loopTiming indicates that the recovered receive clock is used as the transmit clock.
localTiming indicates that a local clock source is used or that an external clock is attached to the box containing the interface.
throughTiming indicates that transmit clock is derived from the recovered receive clock of another DS3 interface.
dsx3InvalidIntervals
1.3.6.1.2.1.10.30.5.1.12
INTEGER (0..96) · Integer32
The number of intervals in the range from 0 to dsx3ValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations).
dsx3LineLength
1.3.6.1.2.1.10.30.5.1.13
INTEGER (0..64000) · Integer32 · meters
The length of the ds3 line in meters. This object provides information for line build out circuitry if it exists and can use this object to adjust the line build out.
dsx3LineStatusLastChange
1.3.6.1.2.1.10.30.5.1.14
TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be
defined in the description of any object defined using this type.
If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks
The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value.
dsx3LineStatusChangeTrapEnable
1.3.6.1.2.1.10.30.5.1.15
INTEGER1 = enabled2 = disabled · Integer32
Indicates whether dsx3LineStatusChange traps should be generated for this interface.
dsx3LoopbackStatus
1.3.6.1.2.1.10.30.5.1.16
INTEGER (1..127) · Integer32
This variable represents the current state of the loopback on the DS3 interface. It contains information about loopbacks established by a manager and remotely from the far end.
The dsx3LoopbackStatus is a bit map represented as a sum, therefore is can represent multiple loopbacks simultaneously.
The various bit positions are:
1 dsx3NoLoopback
2 dsx3NearEndPayloadLoopback
4 dsx3NearEndLineLoopback
8 dsx3NearEndOtherLoopback
16 dsx3NearEndInwardLoopback
32 dsx3FarEndPayloadLoopback
64 dsx3FarEndLineLoopback
Indicates whether this ds3/e3 is channelized or unchannelized. The value of enabledDs1 indicates
that this is a DS3 channelized into DS1s. The value of enabledDs3 indicated that this is a DS3 channelized into DS2s. Setting this object will cause the creation or deletion of DS2 or DS1 entries in the ifTable.
dsx3Ds1ForRemoteLoop
1.3.6.1.2.1.10.30.5.1.18
INTEGER (0..29) · Integer32
Indicates which DS1/E1 on this DS3/E3 will be indicated in the remote ds1 loopback request. A value of 0 means no DS1 will be looped. A value of 29 means all DS1s/E1s will be looped.
dsx3CurrentTable
1.3.6.1.2.1.10.30.6
Index: dsx3CurrentIndex
The DS3/E3 current table contains various statistics being collected for the current 15 minute interval.
dsx3CurrentIndex
1.3.6.1.2.1.10.30.6.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance.
dsx3CurrentPESs
1.3.6.1.2.1.10.30.6.1.2
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of P-bit Errored Seconds.
dsx3CurrentPSESs
1.3.6.1.2.1.10.30.6.1.3
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of P-bit Severely Errored Seconds.
dsx3CurrentSEFSs
1.3.6.1.2.1.10.30.6.1.4
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Severely Errored Framing Seconds.
dsx3CurrentUASs
1.3.6.1.2.1.10.30.6.1.5
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Unavailable Seconds.
dsx3CurrentLCVs
1.3.6.1.2.1.10.30.6.1.6
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Line Coding Violations.
dsx3CurrentPCVs
1.3.6.1.2.1.10.30.6.1.7
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of P-bit Coding Violations.
dsx3CurrentLESs
1.3.6.1.2.1.10.30.6.1.8
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The number of Line Errored Seconds.
dsx3CurrentCCVs
1.3.6.1.2.1.10.30.6.1.9
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The number of C-bit Coding Violations.
dsx3CurrentCESs
1.3.6.1.2.1.10.30.6.1.10
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The number of C-bit Errored Seconds.
dsx3CurrentCSESs
1.3.6.1.2.1.10.30.6.1.11
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The number of C-bit Severely Errored Seconds.
dsx3IntervalTable
1.3.6.1.2.1.10.30.7
Index: dsx3IntervalIndex · dsx3IntervalNumber
The DS3/E3 Interval Table contains various statistics collected by each DS3/E3 Interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15 minute intervals. Each row in this table represents one such interval (identified by dsx3IntervalNumber) and for one specific interface (identified by dsx3IntervalIndex).
dsx3IntervalIndex
1.3.6.1.2.1.10.30.7.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance.
dsx3IntervalNumber
1.3.6.1.2.1.10.30.7.1.2
INTEGER (1..96) · Integer32
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1.
dsx3IntervalPESs
1.3.6.1.2.1.10.30.7.1.3
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of P-bit Errored Seconds.
dsx3IntervalPSESs
1.3.6.1.2.1.10.30.7.1.4
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of P-bit Severely Errored Seconds.
dsx3IntervalSEFSs
1.3.6.1.2.1.10.30.7.1.5
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Severely Errored Framing Seconds.
dsx3IntervalUASs
1.3.6.1.2.1.10.30.7.1.6
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Unavailable Seconds. This object may decrease if the occurrence of unavailable seconds occurs across an interval boundary.
dsx3IntervalLCVs
1.3.6.1.2.1.10.30.7.1.7
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Line Coding Violations.
dsx3IntervalPCVs
1.3.6.1.2.1.10.30.7.1.8
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of P-bit Coding Violations.
dsx3IntervalLESs
1.3.6.1.2.1.10.30.7.1.9
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The number of Line Errored Seconds (BPVs or
illegal zero sequences).
dsx3IntervalCCVs
1.3.6.1.2.1.10.30.7.1.10
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The number of C-bit Coding Violations.
dsx3IntervalCESs
1.3.6.1.2.1.10.30.7.1.11
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The number of C-bit Errored Seconds.
dsx3IntervalCSESs
1.3.6.1.2.1.10.30.7.1.12
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The number of C-bit Severely Errored Seconds.
dsx3IntervalValidData
1.3.6.1.2.1.10.30.7.1.13
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
This variable indicates if the data for this interval is valid.
dsx3TotalTable
1.3.6.1.2.1.10.30.8
Index: dsx3TotalIndex
The DS3/E3 Total Table contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval.
dsx3TotalIndex
1.3.6.1.2.1.10.30.8.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3/E3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance.
dsx3TotalPESs
1.3.6.1.2.1.10.30.8.1.2
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of P-bit Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalPSESs
1.3.6.1.2.1.10.30.8.1.3
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of P-bit Severely Errored Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalSEFSs
1.3.6.1.2.1.10.30.8.1.4
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Severely Errored Framing Seconds, encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalUASs
1.3.6.1.2.1.10.30.8.1.5
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Unavailable Seconds, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalLCVs
1.3.6.1.2.1.10.30.8.1.6
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Line Coding Violations encountered by a DS3/E3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalPCVs
1.3.6.1.2.1.10.30.8.1.7
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of P-bit
Coding Violations, encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalLESs
1.3.6.1.2.1.10.30.8.1.8
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The number of Line Errored Seconds (BPVs or
illegal zero sequences) encountered by a DS3/E3
interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalCCVs
1.3.6.1.2.1.10.30.8.1.9
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The number of C-bit Coding Violations encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalCESs
1.3.6.1.2.1.10.30.8.1.10
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The number of C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3TotalCSESs
1.3.6.1.2.1.10.30.8.1.11
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The number of C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3FarEndConfigTable
1.3.6.1.2.1.10.30.9
Index: dsx3FarEndLineIndex
The DS3 Far End Configuration Table contains configuration information reported in the C-bits from the remote end.
dsx3FarEndLineIndex
1.3.6.1.2.1.10.30.9.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this
index is the same interface as identified by the same value an dsx3LineIndex object instance.
dsx3FarEndEquipCode
1.3.6.1.2.1.10.30.9.1.2
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..10) · OCTET STRING · hint 255a
This is the Far End Equipment Identification code that describes the specific piece of equipment. It is sent within the Path Identification Message.
dsx3FarEndLocationIDCode
1.3.6.1.2.1.10.30.9.1.3
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..11) · OCTET STRING · hint 255a
This is the Far End Location Identification code that describes the specific location of the equipment. It is sent within the Path Identification Message.
dsx3FarEndFrameIDCode
1.3.6.1.2.1.10.30.9.1.4
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..10) · OCTET STRING · hint 255a
This is the Far End Frame Identification code that identifies where the equipment is located within a building at a given location. It is sent within the Path Identification Message.
dsx3FarEndUnitCode
1.3.6.1.2.1.10.30.9.1.5
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..6) · OCTET STRING · hint 255a
This is the Far End code that identifies the equipment location within a bay. It is sent within the Path Identification Message.
dsx3FarEndFacilityIDCode
1.3.6.1.2.1.10.30.9.1.6
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..38) · OCTET STRING · hint 255a
This code identifies a specific Far End DS3 path. It is sent within the Path Identification Message.
dsx3FarEndCurrentTable
1.3.6.1.2.1.10.30.10
Index: dsx3FarEndCurrentIndex
The DS3 Far End Current table contains various statistics being collected for the current 15 minute interval. The statistics are collected from the far end block error code within the C- bits.
dsx3FarEndCurrentIndex
1.3.6.1.2.1.10.30.10.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex.
dsx3FarEndTimeElapsed
1.3.6.1.2.1.10.30.10.1.2
INTEGER (0..899) · Integer32
The number of seconds that have elapsed since the beginning of the far end current error-measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value.
dsx3FarEndValidIntervals
1.3.6.1.2.1.10.30.10.1.3
INTEGER (0..96) · Integer32
The number of previous far end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute far end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available.
dsx3FarEndCurrentCESs
1.3.6.1.2.1.10.30.10.1.4
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Far End C-bit Errored Seconds.
dsx3FarEndCurrentCSESs
1.3.6.1.2.1.10.30.10.1.5
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Far End C-bit Severely Errored Seconds.
dsx3FarEndCurrentCCVs
1.3.6.1.2.1.10.30.10.1.6
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count.
dsx3FarEndCurrentUASs
1.3.6.1.2.1.10.30.10.1.7
PerfCurrentCountA counter associated with a performance measurement in a current 15 minute measurement interval. The value of this counter starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the counter is stored in the first 15 minute history interval, and the CurrentCount is restarted at zero. In the case where the agent has no valid data available for the current interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). · Gauge32
The counter associated with the number of Far End unavailable seconds.
dsx3FarEndInvalidIntervals
1.3.6.1.2.1.10.30.10.1.8
INTEGER (0..96) · Integer32
The number of intervals in the range from 0 to dsx3FarEndValidIntervals for which no data is available. This object will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations).
The DS3 Far End Interval Table contains various
statistics collected by each DS3 interface over the previous 24 hours of operation. The past 24 hours are broken into 96 completed 15 minute intervals.
dsx3FarEndIntervalIndex
1.3.6.1.2.1.10.30.11.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex.
dsx3FarEndIntervalNumber
1.3.6.1.2.1.10.30.11.1.2
INTEGER (1..96) · Integer32
A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is
the 15 minutes interval completed 23 hours and 45 minutes prior to interval 1.
dsx3FarEndIntervalCESs
1.3.6.1.2.1.10.30.11.1.3
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals. In the case where the agent is a proxy and data is not available, return noSuchInstance.
dsx3FarEndIntervalCSESs
1.3.6.1.2.1.10.30.11.1.4
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Far End C-bit Severely Errored Seconds.
dsx3FarEndIntervalCCVs
1.3.6.1.2.1.10.30.11.1.5
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count.
dsx3FarEndIntervalUASs
1.3.6.1.2.1.10.30.11.1.6
PerfIntervalCountA counter associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist (for example, a noSuchName error for SNMPv1 and a noSuchInstance for SNMPv2 GET operation). In a system supporting a history of n intervals with IntervalCount(1) and IntervalCount(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval: - discard the value of IntervalCount(n) - the value of IntervalCount(i) becomes that of IntervalCount(i-1) for n >= i > 1 - the value of IntervalCount(1) becomes that of CurrentCount - the TotalCount, if supported, is adjusted. · Gauge32
The counter associated with the number of Far End unavailable seconds.
dsx3FarEndIntervalValidData
1.3.6.1.2.1.10.30.11.1.7
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
This variable indicates if the data for this interval is valid.
dsx3FarEndTotalTable
1.3.6.1.2.1.10.30.12
Index: dsx3FarEndTotalIndex
The DS3 Far End Total Table contains the cumulative sum of the various statistics for the 24 hour period preceding the current interval.
dsx3FarEndTotalIndex
1.3.6.1.2.1.10.30.12.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is identical to the interface identified by the same value of dsx3LineIndex.
dsx3FarEndTotalCESs
1.3.6.1.2.1.10.30.12.1.2
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3FarEndTotalCSESs
1.3.6.1.2.1.10.30.12.1.3
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3FarEndTotalCCVs
1.3.6.1.2.1.10.30.12.1.4
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3FarEndTotalUASs
1.3.6.1.2.1.10.30.12.1.5
PerfTotalCountA counter associated with a performance measurements aggregating the previous valid 15 minute measurement intervals. (Intervals for which no valid data was available are not counted) · Gauge32
The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in the previous 24 hour interval. Invalid 15 minute intervals count as 0.
dsx3FracTable
1.3.6.1.2.1.10.30.13
Index: dsx3FracIndex · dsx3FracNumber
This table is deprecated in favour of using ifStackTable.
Implementation of this table was optional. It was designed for those systems dividing a DS3/E3 into channels containing different data streams that are of local interest.
The DS3/E3 fractional table identifies which DS3/E3 channels associated with a CSU are being used to support a logical interface, i.e., an entry in the interfaces table from the Internet- standard MIB.
For example, consider a DS3 device with 4 high speed links carrying router traffic, a feed for voice, a feed for video, and a synchronous channel for a non-routed protocol. We might describe the allocation of channels, in the dsx3FracTable, as follows:
dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4
dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6
dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6
dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6
dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6
dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6
dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6
dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6
dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6
dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6
dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6
dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6
dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6
dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6
For dsx3M23, dsx3 SYNTRAN, dsx3CbitParity, and
dsx3ClearChannel there are 28 legal channels,
numbered 1 through 28.
For e3Framed there are 16 legal channels, numbered 1 through 16. The channels (1..16) correspond directly to the equivalently numbered time-slots.
dsx3FracIndex
1.3.6.1.2.1.10.30.13.1.1
INTEGER (1..2147483647) · Integer32
The index value which uniquely identifies the
DS3 interface to which this entry is applicable
The interface identified by a particular value
of this index is the same interface as
identified by the same value an dsx3LineIndex
object instance.
dsx3FracNumber
1.3.6.1.2.1.10.30.13.1.2
INTEGER (1..31) · Integer32
The channel number for this entry.
dsx3FracIfIndex
1.3.6.1.2.1.10.30.13.1.3
INTEGER (0..2147483647) · Integer32
An index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same
interface as identified by the same value an
ifIndex object instance. If no interface is currently using a channel, the value should be
zero. If a single interface occupies more than
one time slot, that ifIndex value will be found
in multiple time slots.
Trap details
dsx3LineStatusChange
1.3.6.1.2.1.10.30.15.0.1
A dsx3LineStatusChange trap is sent when the value of an instance of dsx3LineStatus changes. It can be utilized by an NMS to trigger polls. When the line status change results in a lower level line status change (i.e., ds1), then no traps for the lower level are sent.
dsx3LineStatus
1.3.6.1.2.1.10.30.5.1.10
INTEGER (1..4095) · Integer32
This variable indicates the Line Status of the interface. It contains loopback state information and failure state information. The dsx3LineStatus is a bit map represented as a sum, therefore, it can represent multiple failures and a loopback (see dsx3LoopbackConfig object for the type of loopback) simultaneously. The dsx3NoAlarm must be set if and only if no other flag is set.
If the dsx3loopbackState bit is set, the loopback in effect can be determined from the dsx3loopbackConfig object. The various bit positions are:
1 dsx3NoAlarm No alarm present
2 dsx3RcvRAIFailure Receiving Yellow/Remote
Alarm Indication
4 dsx3XmitRAIAlarm Transmitting Yellow/Remote
Alarm Indication
8 dsx3RcvAIS Receiving AIS failure state
16 dsx3XmitAIS Transmitting AIS
32 dsx3LOF Receiving LOF failure state
64 dsx3LOS Receiving LOS failure state
128 dsx3LoopbackState Looping the received signal
256 dsx3RcvTestCode Receiving a Test Pattern
512 dsx3OtherFailure any line status not defined
here
1024 dsx3UnavailSigState Near End in Unavailable
Signal State
2048 dsx3NetEquipOOS Carrier Equipment Out of
Service
dsx3LineStatusLastChange
1.3.6.1.2.1.10.30.5.1.14
TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be
defined in the description of any object defined using this type.
If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks
The value of MIB II's sysUpTime object at the time this DS3/E3 entered its current line status state. If the current state was entered prior to the last re-initialization of the proxy-agent, then this object contains a zero value.