This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID that provide extensions to the industry proposed standard ENTITY-SENSOR-MIB.
EnabledStatus1 = enabled2 = disabledA simple status value for the object. · Integer32
This object indicates whether an etsysEntitySfpSensorStateChng notification will be sent when the sensor state changes as defined by etsysEntitySfpSensorState.
Table details
etsysEntityTempSensorExtTable
1.3.6.1.4.1.5624.1.2.85.1.1.1
Index: entPhysicalIndex
A table of per temperature sensor information that extends the general information provided in entPhySensorTable as defined in RFC3433. This table should contain an entry for every object contained in entPhySensorTable that has an entPhySensorType of type celsius(8).
PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d
This object indicates the state of the temperature sensor.
etsysEntityTempSensorHotTemp
1.3.6.1.4.1.5624.1.2.85.1.1.1.1.2
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The temperature value above which the ambient temperature is deemed to be hot.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntityTempSensorWarmTemp
1.3.6.1.4.1.5624.1.2.85.1.1.1.1.3
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The temperature value above which the ambient temperature is deemed to be warm, if it is below or equal the hot value.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntityTempSensorCoolTemp
1.3.6.1.4.1.5624.1.2.85.1.1.1.1.4
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The temperature value below which the ambient temperature is deemed to be cool, if it is above or equal the cold value.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntityTempSensorColdTemp
1.3.6.1.4.1.5624.1.2.85.1.1.1.1.5
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The temperature value below which the ambient temperature is deemed to be cold.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntityTempSensorTrapEnable
1.3.6.1.4.1.5624.1.2.85.1.1.1.1.6
EnabledStatus1 = enabled2 = disabledA simple status value for the object. · Integer32
This object indicates whether the etsysEntityTempSensorStateChng notification will be sent when the sensor state changes as defined by etsysEntityTempSensorState.
etsysEntitySfpSensorExtTable
1.3.6.1.4.1.5624.1.2.85.1.2.1
Index: entPhysicalIndex
A table of per SFP sensor information that extends the general information provided in entPhySensorTable as defined in RFC3433.
PhysicalIndexAn arbitrary value that uniquely identifies the physical entity. The value should be a small positive integer. Index values for different physical entities are not necessarily contiguous. (1..2147483647) · Integer32 · hint d
This object indicates the state of the SFP sensor.
etsysEntitySfpSensorHighAlarm
1.3.6.1.4.1.5624.1.2.85.1.2.1.1.2
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The threshold value above which the sensor reading indicates an alarm state.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntitySfpSensorHighWarning
1.3.6.1.4.1.5624.1.2.85.1.2.1.1.3
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The threshold value above which the sensor reading indicates a warning state, if it is below or equal the hi alarm value.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntitySfpSensorLowWarning
1.3.6.1.4.1.5624.1.2.85.1.2.1.1.4
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The threshold value below which the sensor reading indicates a warning state, if it is above or equal the lo alarm value.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
etsysEntitySfpSensorLowAlarm
1.3.6.1.4.1.5624.1.2.85.1.2.1.1.5
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The threshold value below which the sensor reading indicates an alarm state.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
Trap details
etsysEntityTempSensorStateChng
1.3.6.1.4.1.5624.1.2.85.1.0.1
An etsysEntityTempSensorStateChng trap signifies that the SNMP entity, acting in an agent role, has detected the transition of etsysEntityTempSensorState from one enumerated state to another. It is RECOMMENDED that devices implementing this trap optionally varbind the entPhysicalName and entPhysicalDescr objects for this sensor.
This object indicates the state of the temperature sensor.
entPhySensorOperStatus
1.3.6.1.2.1.99.1.1.1.5
EntitySensorStatus1 = ok2 = unavailable3 = nonoperationalAn object using this data type represents the operational status of a physical sensor.
The value 'ok(1)' indicates that the agent can obtain the sensor value.
The value 'unavailable(2)' indicates that the agent presently cannot obtain the sensor value.
The value 'nonoperational(3)' indicates that the agent believes the sensor is broken. The sensor could have a hard failure (disconnected wire), or a soft failure such as out- of-range, jittery, or wildly fluctuating readings. · Integer32
The operational status of the sensor.
entPhySensorScale
1.3.6.1.2.1.99.1.1.1.2
EntitySensorDataScale1 = yocto2 = zepto3 = atto4 = femto5 = pico6 = nano7 = micro8 = milli9 = units10 = kilo11 = mega12 = giga13 = tera14 = exa15 = peta16 = zetta17 = yottaAn object using this data type represents a data scaling factor, represented with an International System of Units (SI) prefix. The actual data units are determined by examining an object of this type together with the associated EntitySensorDataType object.
An object of this type SHOULD be defined together with objects of type EntitySensorDataType and EntitySensorPrecision. Together, associated objects of these three types are used to identify the semantics of an object of type EntitySensorValue.Reference: The International System of Units (SI), National Institute of Standards and Technology, Spec. Publ. 330, August 1991. · Integer32
The exponent to apply to values returned by the associated entPhySensorValue object.
This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation.
entPhySensorPrecision
1.3.6.1.2.1.99.1.1.1.3
EntitySensorPrecisionAn object using this data type represents a sensor precision range.
An object of this type SHOULD be defined together with objects of type EntitySensorDataType and EntitySensorDataScale. Together, associated objects of these three types are used to identify the semantics of an object of type EntitySensorValue.
If an object of this type contains a value in the range 1 to 9, it represents the number of decimal places in the fractional part of an associated EntitySensorValue fixed- point number.
If an object of this type contains a value in the range -8 to -1, it represents the number of accurate digits in the associated EntitySensorValue fixed-point number.
The value zero indicates the associated EntitySensorValue object is not a fixed-point number.
Agent implementors must choose a value for the associated EntitySensorPrecision object so that the precision and accuracy of the associated EntitySensorValue object is correctly indicated.
For example, a physical entity representing a temperature sensor that can measure 0 degrees to 100 degrees C in 0.1 degree increments, +/- 0.05 degrees, would have an EntitySensorPrecision value of '1', an EntitySensorDataScale value of 'units(9)', and an EntitySensorValue ranging from '0' to '1000'. The EntitySensorValue would be interpreted as 'degrees C * 10'. (-8..9) · Integer32
The number of decimal places of precision in fixed-point sensor values returned by the associated entPhySensorValue object.
This object SHOULD be set to '0' when the associated entPhySensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation.
entPhySensorValue
1.3.6.1.2.1.99.1.1.1.4
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The most recent measurement obtained by the agent for this sensor.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
entPhySensorUnitsDisplay
1.3.6.1.2.1.99.1.1.1.6
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t
A textual description of the data units that should be used in the display of entPhySensorValue.
etsysEntitySfpSensorStateChng
1.3.6.1.4.1.5624.1.2.85.1.0.2
An etsysEntitySfpSensorStateChng trap signifies that the SNMP entity, acting in an agent role, has detected the transition of etsysEntitySfpSensorState from one enumerated state to another. It is RECOMMENDED that devices implementing this trap optionally varbind the entPhysicalName and entPhysicalDescr objects for this sensor.
This object indicates the state of the SFP sensor.
entPhySensorOperStatus
1.3.6.1.2.1.99.1.1.1.5
EntitySensorStatus1 = ok2 = unavailable3 = nonoperationalAn object using this data type represents the operational status of a physical sensor.
The value 'ok(1)' indicates that the agent can obtain the sensor value.
The value 'unavailable(2)' indicates that the agent presently cannot obtain the sensor value.
The value 'nonoperational(3)' indicates that the agent believes the sensor is broken. The sensor could have a hard failure (disconnected wire), or a soft failure such as out- of-range, jittery, or wildly fluctuating readings. · Integer32
The operational status of the sensor.
entPhySensorScale
1.3.6.1.2.1.99.1.1.1.2
EntitySensorDataScale1 = yocto2 = zepto3 = atto4 = femto5 = pico6 = nano7 = micro8 = milli9 = units10 = kilo11 = mega12 = giga13 = tera14 = exa15 = peta16 = zetta17 = yottaAn object using this data type represents a data scaling factor, represented with an International System of Units (SI) prefix. The actual data units are determined by examining an object of this type together with the associated EntitySensorDataType object.
An object of this type SHOULD be defined together with objects of type EntitySensorDataType and EntitySensorPrecision. Together, associated objects of these three types are used to identify the semantics of an object of type EntitySensorValue.Reference: The International System of Units (SI), National Institute of Standards and Technology, Spec. Publ. 330, August 1991. · Integer32
The exponent to apply to values returned by the associated entPhySensorValue object.
This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation.
entPhySensorPrecision
1.3.6.1.2.1.99.1.1.1.3
EntitySensorPrecisionAn object using this data type represents a sensor precision range.
An object of this type SHOULD be defined together with objects of type EntitySensorDataType and EntitySensorDataScale. Together, associated objects of these three types are used to identify the semantics of an object of type EntitySensorValue.
If an object of this type contains a value in the range 1 to 9, it represents the number of decimal places in the fractional part of an associated EntitySensorValue fixed- point number.
If an object of this type contains a value in the range -8 to -1, it represents the number of accurate digits in the associated EntitySensorValue fixed-point number.
The value zero indicates the associated EntitySensorValue object is not a fixed-point number.
Agent implementors must choose a value for the associated EntitySensorPrecision object so that the precision and accuracy of the associated EntitySensorValue object is correctly indicated.
For example, a physical entity representing a temperature sensor that can measure 0 degrees to 100 degrees C in 0.1 degree increments, +/- 0.05 degrees, would have an EntitySensorPrecision value of '1', an EntitySensorDataScale value of 'units(9)', and an EntitySensorValue ranging from '0' to '1000'. The EntitySensorValue would be interpreted as 'degrees C * 10'. (-8..9) · Integer32
The number of decimal places of precision in fixed-point sensor values returned by the associated entPhySensorValue object.
This object SHOULD be set to '0' when the associated entPhySensorType value is not a fixed-point type: e.g., 'percentRH(9)', 'rpm(10)', 'cmm(11)', or 'truthvalue(12)'.
This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation.
entPhySensorValue
1.3.6.1.2.1.99.1.1.1.4
EntitySensorValueAn object using this data type represents an Entity Sensor value. An object of this type SHOULD be defined together with objects of type EntitySensorDataType, EntitySensorDataScale and EntitySensorPrecision. Together, associated objects of those three types are used to identify the semantics of an object of this data type.
The semantics of an object using this data type are determined by the value of the associated EntitySensorDataType object.
If the associated EntitySensorDataType object is equal to 'voltsAC(3)', 'voltsDC(4)', 'amperes(5)', 'watts(6), 'hertz(7)', 'celsius(8)', or 'cmm(11)', then an object of this type MUST contain a fixed point number ranging from -999,999,999 to +999,999,999. The value -1000000000 indicates an underflow error. The value +1000000000 indicates an overflow error. The EntitySensorPrecision indicates how many fractional digits are represented in the associated EntitySensorValue object.
If the associated EntitySensorDataType object is equal to 'percentRH(9)', then an object of this type MUST contain a number ranging from 0 to 100.
If the associated EntitySensorDataType object is equal to 'rpm(10)', then an object of this type MUST contain a number ranging from -999,999,999 to +999,999,999.
If the associated EntitySensorDataType object is equal to 'truthvalue(12)', then an object of this type MUST contain either the value 'true(1)' or the value 'false(2)'.
If the associated EntitySensorDataType object is equal to 'other(1)' or unknown(2)', then an object of this type MUST contain a number ranging from -1000000000 to 1000000000. (-1000000000..1000000000) · Integer32
The most recent measurement obtained by the agent for this sensor.
To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.
entPhySensorUnitsDisplay
1.3.6.1.2.1.99.1.1.1.6
SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form.
To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279].
Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited.
The use of control codes should be avoided.
When it is necessary to represent a newline, the control code sequence CR LF should be used.
The use of leading or trailing white space should be avoided.
For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided.
For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding.
UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding.
Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416].
Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t
A textual description of the data units that should be used in the display of entPhySensorValue.