This MIB module defines a portion of the SNMP MIB under the Enterasys Networks enterprise OID pertaining to proprietary extensions to the IEEE8021-CFM-MIB.
EnabledStatus1 = enabled2 = disabledA simple status value for the object. · Integer32
The global enabled/disabled status of the CFM functionality on the managed entity.
enabled(1) - CFM is enabled globally on the managed entity. disabled(2)- CFM is disabled globally on the managed entity.
etsysIeee8021CfmClearBridgeCcmDatabase
1.3.6.1.4.1.5624.1.2.524.1.1.4
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
If set to true, the bridge CCM database will be cleared.
Table details
etsysIeee8021CfmExtMemPoolTable
1.3.6.1.4.1.5624.1.2.524.1.1.2
Index: etsysIeee8021CfmExtMemPoolIndex
Provides information related to the memory pools allocated on the managed entity to support configuration of CFM elements.
The following information is provided: - Memory pool size - Current number of elements in use - High water mark of pool usage.
etsysIeee8021CfmExtMemPoolIndex
1.3.6.1.4.1.5624.1.2.524.1.1.2.1.1
EtsysIeee8021CfmExtMemPool1 = memPoolMD2 = memPoolMA3 = memPoolMEP4 = memPoolMAMEP5 = memPoolRMEP6 = memPoolMHF7 = memPoolMACOMPThis textual convention defines the list of CFM-related memory pools, allocated on the managed entity, that will be monitored by the CFM application in order to provide the usage of each memory pool.
memPoolMD(1) Memory pool to store Maintenance Domain
(MD)-related information.
memPoolMA(2) Memory pool to store Maintenance Association
(MA)-related information.
memPoolMEP(3) Memory pool to store Maintenace End Point
(MEP)-related information.
memPoolMAMEP(4) Memory pool to store MA MEP List Entry-related
information.
memPoolRMEP(5) Memory pool to store Remote MEP-related
information
memPoolMHF(6) Memory pool to store MIP Half Function (MHF)-
related information.
memPoolMACOMP(7) Memory pool to store part of the MA Table
that is variable accross the Bridges in a MD, or across the components of a single Bridge. · Integer32
The index to the Mem Pool Table.
etsysIeee8021CfmExtMemPoolSize
1.3.6.1.4.1.5624.1.2.524.1.1.2.1.2
EtsysIeee8021CfmExtMemPoolMaxSizeInteger that especifies the maximum size of a memory pool. (1..5000) · Unsigned32 · hint d
The total number of elements of the memory pool.
etsysIeee8021CfmExtMemPoolInUse
1.3.6.1.4.1.5624.1.2.524.1.1.2.1.3
EtsysIeee8021CfmExtMemPoolMaxSizeInteger that especifies the maximum size of a memory pool. (1..5000) · Unsigned32 · hint d
The current number of elements of the memory pool in use.
etsysIeee8021CfmExtMemPoolHighWaterMark
1.3.6.1.4.1.5624.1.2.524.1.1.2.1.4
EtsysIeee8021CfmExtMemPoolMaxSizeInteger that especifies the maximum size of a memory pool. (1..5000) · Unsigned32 · hint d
The MIP CCM Database. A database, maintained by every MEP and MHF, that maintains Continuity Check information about other MEPs in the Maintenance Domain.
The index to the Maintenance Domain table.
dot1agCfmMdTableNextIndex needs to be inspected to find an available index for row-creation.
Referential integrity is required, i.e., the index needs to be persistent upon a reboot or restart of a device. The index can never be reused for other Maintenance Domain. The index value SHOULD keep increasing up to the time that they wrap around. This is to facilitate access control based on OID.
dot1agCfmMaIndex
Unsigned32 (1..4294967295)
Index of the MA table dot1agCfmMdMaNextIndex needs to be inspected to find an available index for row-creation.
etsysIeee8021CfmMipCcmDbMpIdentifier
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.1
Unsigned32 (1..8191 | 16383..32767)
Identifier of a MP whose information from the MIP CCM Database is to be returned.
etsysIeee8021CfmMipCcmDbFid
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.2
Unsigned32 (0..4094)
FID of the item in the MIP CCM Database to be returned.
etsysIeee8021CfmMipCcmDbMacAddress
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.3
MacAddressRepresents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires MAC addresses to be transmitted most significant bit first. SIZE (6) · OCTET STRING · hint 1x:
The MAC address of the item in the MIP CCM Database to be returned.
etsysIeee8021CfmMipCcmDbMpIfIndex
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.4
InterfaceIndexOrZeroThis textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits the additional value of zero. the value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where interface was unknown, or when none or all interfaces need to be referenced. (0..2147483647) · Integer32 · hint d
The interface index of the interface of the MP of the item in the MIP CCM Database to be returned.
etsysIeee8021CfmMipCcmDbMpMdLevel
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.5
Dot1agCfmMDLevelInteger identifying the Maintenance Domain Level (MD Level). Higher numbers correspond to higher Maintenance Domains, those with the greatest physical reach, with the highest values for customers' CFM PDUs. Lower numbers correspond to lower Maintenance Domains, those with more limited physical reach, with the lowest values for CFM PDUs protecting single Bridges or physical links.Reference: 18.3, 21.4.1 (0..7) · Integer32 · hint d
Reference: 12.14.2.1.2:b
The MD Level of the MP of the item in the MIP CCM Database to be returned.
etsysIeee8021CfmMipCcmDbMpDirection
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.6
Dot1agCfmMpDirection1 = down2 = upIndicates the direction in which the Maintenance association (MEP or MIP) faces on the Bridge Port:
down(1) Sends Continuity Check Messages away from the
MAC Relay Entity.
up(2) Sends Continuity Check Messages towards the
MAC Relay Entity.Reference: 12.14.6.3.2:c · Integer32
Reference: 12.14.2.1.2:c
The Direction in which the MP faces on the Bridge Port of the item in the MIP CCM Database to be returned.
etsysIeee8021CfmMipCcmDbLearnedIfIndex
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.7
InterfaceIndexOrZeroThis textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits the additional value of zero. the value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where interface was unknown, or when none or all interfaces need to be referenced. (0..2147483647) · Integer32 · hint d
The interface index of the interface on which the MIP CCM of the MIP CCM database item was learned on.
etsysIeee8021CfmMipCcmDbTimeStamp
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.8
TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be
defined in the description of any object defined using this type.
If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks
TimeStamp of the item in the MIP CCM Database to be returned. It is the value of sysUpTime at the last time it was modified.
etsysIeee8021CfmMipCcmDbComponentId
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.9
IEEE8021PbbComponentIdentifierThe component identifier is used to distinguish between the multiple virtual Bridge instances within a PB or PBB. Each virtual Bridge instance is called a component. In simple situations where there is only a single component the default value is 1. The component is identified by a component identifier unique within the BEB and by a MAC address unique within the PBBN. Each component is associated with a Backbone Edge Bridge (BEB) Configuration managed object.Reference: 12.3 l) (1..4294967295) · Unsigned32 · hint d
Reference: 12.3 l)
The bridge component within the system to which the information in this etsysIeee8021CfmMipCcmDbEntry applies. If the system is not a Bridge, or if only one component is present in the Bridge, then this variable (index) MUST be equal to 1.
etsysIeee8021CfmMipCcmDbPrimarySelectorType
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.10
IEEE8021ServiceSelectorType1 = vlanId2 = isid3 = tesid4 = segid5 = path-tesid6 = group-isid7 = ieeeReservedA value that represents a type (and thereby the format) of a IEEE8021ServiceSelectorValue. The value can be one of the following:
ieeeReserved(0) Reserved for definition by IEEE 802.1
recommend to not use zero unless absolutely needed.
vlanId(1) 12-Bit identifier as described in IEEE Std 802.1Q.
isid(2) 24-Bit identifier as described in IEEE Std 802.1ah.
tesid(3) 32 Bit identifier as described below.
segid(4) 32 Bit identifier as described below.
path-tesid(5) 32 Bit identifier as described below.
group-isid(6) 24 Bit identifier as described below.
ieeeReserved(7) Reserved for definition by IEEE Std 802.1
To support future extensions, the IEEE8021ServiceSelectorType textual convention SHOULD NOT be subtyped in object type definitions. It MAY be subtyped in compliance statements in order to require only a subset of these address types for a compliant implementation.
The tesid is used as a service selector for MAs that are present in Bridges that implement PBB-TE functionality. A selector of this type is interpreted as a 32 bit unsigned value of type IEEE8021PbbTeTSidId. This type is used to index the ieee8021PbbTeTeSiEspTable to find the ESPs which comprise the TE Service Instance named by this TE-SID value.
The segid is used as a service selector for MAs that are present in Bridges that implement IPS functionality. A selector of this type is interpreted as a 32 bit unsigned value of type IEEE8021TeipsSegid. This type is used to index the Ieee8021TeipsSegTable to find the SMPs which comprise the Infrastructure Segment named by this segid value.
The path-tesid is used as a service selector for SPBM path MAs. A selector of this type is interpreted as a 32 bit unsigned value corresponding to the MA index dot1agCfmMaIndex. This type is used to index the dot1agCfmMepSpbmEspTable to find the ESPs which comprise the SPBM path associated with an SPBM path MA.
The group-isid is used as a service selector for SPBM group MAs. A selector of this type is interpreted as a 24 bit unsigned value corresponding to the I-SID associated with an SPBM group MA.
Implementations MUST ensure that IEEE8021ServiceSelectorType objects and any dependent objects (e.g., IEEE8021ServiceSelectorValue objects) are consistent. An inconsistentValue error MUST be generated if an attempt to change an IEEE8021ServiceSelectorType object would, for example, lead to an undefined IEEE8021ServiceSelectorValue value. · Integer32
Type of the Primary Service Selector identifier indicated by etsysIeee8021CfmMipCcmDbPrimarySelector. See textual convention IEEE8021ServiceSelectorType for details.
etsysIeee8021CfmMipCcmDbPrimarySelector
1.3.6.1.4.1.5624.1.2.524.1.1.3.1.11
IEEE8021ServiceSelectorValueAn integer that uniquely identifies a generic MAC Service. Examples of service selectors are a VLAN-ID (IEEE 802.1Q) and an I-SID (IEEE Std 802.1ah).
An IEEE8021ServiceSelectorValue value is always interpreted within the context of an IEEE8021ServiceSelectorType value. Every usage of the IEEE8021ServiceSelectorValue textual convention is required to specify the IEEE8021ServiceSelectorType object that provides the context. It is suggested that the IEEE8021ServiceSelectorType object be logically registered before the object(s) that use the IEEE8021ServiceSelectorValue textual convention, if they appear in the same logical row.
The value of an IEEE8021ServiceSelectorValue object must always be consistent with the value of the associated IEEE8021ServiceSelectorType object. Attempts to set an IEEE8021ServiceSelectorValue object to a value inconsistent with the associated IEEE8021ServiceSelectorType must fail with an inconsistentValue error.
Note that a MIB object that is defined using this TEXTUAL-CONVENTION SHOULD clarify the maximum value (i.e., 4094, for a VLAN ID). (1..4294967295) · Unsigned32 · hint d
Primary Service Selector identifier of a Service Instance. See IEEE8021ServiceSelectorValue for details.
The index to the Maintenance Domain table.
dot1agCfmMdTableNextIndex needs to be inspected to find an available index for row-creation.
Referential integrity is required, i.e., the index needs to be persistent upon a reboot or restart of a device. The index can never be reused for other Maintenance Domain. The index value SHOULD keep increasing up to the time that they wrap around. This is to facilitate access control based on OID.
dot1agCfmMaIndex
Unsigned32 (1..4294967295)
Index of the MA table dot1agCfmMdMaNextIndex needs to be inspected to find an available index for row-creation.
dot1agCfmMepIdentifier
Dot1agCfmMepIdMaintenance association Endpoint Identifier (MEPID): A small integer, unique over a given Maintenance Association, identifying a specific MEP.Reference: 3.132, 19.2.1 (1..8191) · Unsigned32 · hint d
Reference: 3.132, 19.2, 12.14.7
Integer that is unique among all the MEPs in the same MA. Other definition is: a small integer, unique over a given Maintenance Association, identifying a specific Maintenance association Endpoint (3.132).
MEP Identifier is also known as the MEPID.
etsysIeee8021CfmExtMepLowPrDefSyslog
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.1
Dot1agCfmLowestAlarmPri1 = allDef2 = macRemErrXcon3 = remErrXcon4 = errXcon5 = xcon6 = noXconAn integer value specifying the lowest priority defect that is allowed to generate a Fault Alarm (20.9.5), either:
allDef(1) DefRDICCM, DefMACstatus, DefRemoteCCM,
DefErrorCCM, and DefXconCCM;
macRemErrXcon(2) Only DefMACstatus, DefRemoteCCM,
DefErrorCCM, and DefXconCCM (default);
remErrXcon(3) Only DefRemoteCCM, DefErrorCCM,
and DefXconCCM;
errXcon(4) Only DefErrorCCM and DefXconCCM;
xcon(5) Only DefXconCCM; or
noXcon(6) No defects DefXcon or lower are to be
reported;Reference: 12.14.7.1.3:k, 20.9.5 · Integer32
An integer value specifying the lowest priority defect that is allowed to generate syslog message.
etsysIeee8021CfmExtMepFngStateSyslog
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.2
Dot1agCfmFngState1 = fngReset2 = fngDefect3 = fngReportDefect4 = fngDefectReported5 = fngDefectClearingIndicates the diferent states of the MEP Fault Notification Generator State Machine.
fngReset(1) No defect has been present since the
dot1agCfmMepFngResetTime timer expired, or since the state machine was last reset.
fngDefect(2) A defect is present, but not for a
long enough time to be reported (dot1agCfmMepFngAlarmTime).
fngReportDefect(3) A momentary state during which the
defect is reported by sending a dot1agCfmFaultAlarm notification, if that action is enabled.
fngDefectReported(4) A defect is present, and some defect
has been reported.
fngDefectClearing(5) No defect is present, but the
dot1agCfmMepFngResetTime timer has not yet expired.Reference: 12.14.7.1.3:f, 20.35 · Integer32
Current state of the MEP Fault Notification Generator State Machine for Syslog.
etsysIeee8021CfmExtMepHighestPrDefectSyslog
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.3
Dot1agCfmHighestDefectPri0 = none1 = defRDICCM2 = defMACstatus3 = defRemoteCCM4 = defErrorCCM5 = defXconCCMAn enumerated value, equal to the contents of the variable highestDefect (20.35.9 and Table 20-1), indicating the highest-priority defect that has been present since the MEP Fault Notification Generator State Machine was last in the FNG_RESET state, either:
none(0) no defects since FNG_RESET
defRDICCM(1) DefRDICCM
defMACstatus(2) DefMACstatus
defRemoteCCM(3) DefRemoteCCM
defErrorCCM(4) DefErrorCCM
defXconCCM(5) DefXconCCM
The value 0 is used for no defects so that additional higher priority values can be added, if needed, at a later time, and so that these values correspond with those in Dot1agCfmLowestAlarmPri.Reference: 12.14.7.7.2, 20.1.2, 20.35.9 · Integer32
The highest priority defect that has been present since the MEPs Fault Notification Generator State Machine for Syslog was last in the FNG_RESET state.
etsysIeee8021CfmExtMepDefectsSyslog
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.4
Dot1agCfmMepDefectsA MEP can detect and report a number of defects, and multiple defects can be present at the same time. These defects are:
bDefRDICCM(0) A remote MEP is reported the RDI bit in its last CCM. bDefMACstatus(1) Either some remote MEP is reporting its Interface Status TLV as not isUp, or all remote MEPs are reporting a Port Status TLV that contains some value other than psUp. bDefRemoteCCM(2) The MEP is not receiving valid CCMs from at least one of the remote MEPs. bDefErrorCCM(3) The MEP has received at least one invalid CCM whose CCM Interval has not yet timed out. bDefXconCCM(4) The MEP has received at least one CCM from either another MAID or a lower MD Level whose CCM Interval has not yet timed out.Reference: 12.14.7.1.3:o, 12.14.7.1.3:p, 12.14.7.1.3:q, 12.14.7.1.3:r, 12.14.7.1.3:s. · BITS
A vector of Boolean error conditions maintained by the MEPs Fault Notification Generator State Machine for Syslog from Table 20-1, any of which may be true:
DefRDICCM(0) DefMACstatus(1) DefRemoteCCM(2) DefErrorCCM(3) DefXconCCM(4)
etsysIeee8021CfmExtMepClearCcmDatabase
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.5
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
If set to true, the MEP CCM database will be cleared.
etsysIeee8021CfmExtRxDiscardCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.6
Counter32
The total number of CFM frames received and discarded since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtRxForwardCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.7
Counter32
The total number of CFM frames received and forwarded since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtRxErrorCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.8
Counter32
The total number of CFM frames received with errors since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtTxErrorCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.9
Counter32
The total number of outbound CFM frames that could not be transmitted because of errors since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxCcmCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.10
Counter32
The total number of CFM Continuity Check PDUs received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxCcmErrCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.11
Counter32
The total number of CFM Continuity Check PDUs that triggered a Remote MEP Error received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxCcmXconCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.12
Counter32
The total number of CFM Continuity Check PDUs that triggered a MEP Cross Connect defect received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepTxCcmCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.13
Counter32
The total number of CFM Continuity Check PDUs transmitted since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepTxCcmErrCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.14
Counter32
The total number of outbound CFM Continuity Check PDUs that could not be transmitted because of errors since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxLbmCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.15
Counter32
The total number of CFM Loopback Message PDUs received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepTxLbmCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.16
Counter32
The total number of CFM Loopback Message PDUs transmitted since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxLbrCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.17
Counter32
The total number of CFM Loopback Response PDUs received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepTxLbrCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.18
Counter32
The total number of CFM Loopback Response PDUs transmitted since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxLtmCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.19
Counter32
The total number of CFM Linktrace Message PDUs received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepTxLtmCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.20
Counter32
The total number of CFM Linktrace Message PDUs transmitted since last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepRxLtrCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.21
Counter32
The total number of CFM Linktrace Response PDUs received since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepTxLtrCount
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.22
Counter32
The total number of CFM Linktrace Response PDUs transmitted since the last reboot.
This value should not be maintained across reboot.
etsysIeee8021CfmExtMepClearMepCounters
1.3.6.1.4.1.5624.1.2.524.1.2.1.1.23
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
If set to true, the CFM MEP counters will be cleared.