EZ5 MIB Catalog

ENTERASYS-R2MGMT-MIB

2004-07-08

The Enterasys Networks Proprietary MIB module for entities implementing objects specific to the RoamAbout R2 Wireless Access Platform.

Download ENTERASYS-R2MGMT-MIB.txt Open ENTERASYS-R2MGMT-MIB.txt in a new tab

SCALARS (12) · TABLES (1)

Scalars (12)

NameOID
etsysR2MgmtMemorySize1.3.6.1.4.1.5624.1.2.11.1.1.1
etsysR2MgmtWEBInterface1.3.6.1.4.1.5624.1.2.11.1.1.2
etsysR2MgmtTelnetInterface1.3.6.1.4.1.5624.1.2.11.1.1.3
etsysR2MgmtVlan1.3.6.1.4.1.5624.1.2.11.1.1.4
etsysR2MgmtPowerups1.3.6.1.4.1.5624.1.2.11.1.2.1
etsysR2MgmtResets1.3.6.1.4.1.5624.1.2.11.1.2.2
etsysR2MgmtUnsolicitedResets1.3.6.1.4.1.5624.1.2.11.1.2.3
etsysR2MgmtErrLogNumEntries1.3.6.1.4.1.5624.1.2.11.1.3.1
etsysR2MgmtCrashUploadUseBootp1.3.6.1.4.1.5624.1.2.11.1.4.1
etsysR2MgmtCrashUploadServerIP1.3.6.1.4.1.5624.1.2.11.1.4.2
etsysR2MgmtCrashUploadDirectory1.3.6.1.4.1.5624.1.2.11.1.4.3
etsysR2MgmtUplineDumpMode1.3.6.1.4.1.5624.1.2.11.1.4.4

Tables (1)

NameOID
etsysR2MgmtErrLogTable1.3.6.1.4.1.5624.1.2.11.1.3.2

END OF TOC

Scalar details

etsysR2MgmtMemorySize

1.3.6.1.4.1.5624.1.2.11.1.1.1

Integer32

The size of the memory in the Access Point in Mbytes.

etsysR2MgmtWEBInterface

1.3.6.1.4.1.5624.1.2.11.1.1.2

EnabledStatus1 = enabled2 = disabledA simple status value for the object. · Integer32

Determines whether or not WEB Management is enabled or disabled.

etsysR2MgmtTelnetInterface

1.3.6.1.4.1.5624.1.2.11.1.1.3

EnabledStatus1 = enabled2 = disabledA simple status value for the object. · Integer32

Determines whether or not Telnet Management is enabled or disabled.

etsysR2MgmtVlan

1.3.6.1.4.1.5624.1.2.11.1.1.4

INTEGER (0..4094) · Integer32

When non-zero this object specifies the management VLAN. This is the VLAN that remote management entities must use to communicate with this switch. Zero is a special value that specifies the default behavior, e.g., management on VLAN 1.

etsysR2MgmtPowerups

1.3.6.1.4.1.5624.1.2.11.1.2.1

Counter32

PERSISTENT: The number of times this device was powered on. Power Ups, Management Resets and Unsolicited Resets are all mutually exclusive.

etsysR2MgmtResets

1.3.6.1.4.1.5624.1.2.11.1.2.2

Counter32

PERSISTENT: Number of times the device was initialized with a management command. Power Ups, Management Resets and Unsolicited Resets are all mutually exclusive.

etsysR2MgmtUnsolicitedResets

1.3.6.1.4.1.5624.1.2.11.1.2.3

Counter32

PERSISTENT: Number of times the device initialized itself after encountering a fatal error. Power Ups, Management Resets & Unsolicited Resets are all mutually exclusive.

etsysR2MgmtErrLogNumEntries

1.3.6.1.4.1.5624.1.2.11.1.3.1

INTEGER (0..65535) · Integer32

PERSISTENT: The number of entries in the etsysR2MgmtErrLogTable. The value of this object is initially zero. It is incremented as etsysR2MgmtErrLogEntries are added, to a maximum value. The maximum value is implementation specific.

etsysR2MgmtCrashUploadUseBootp

1.3.6.1.4.1.5624.1.2.11.1.4.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

DURABLE: Controls where the AccessPoint gets the information that it needs to upload crash dumps. When true(1), indicates that the AP should use the BootP protocol to auto-configure parameters such as its own IP address, gateway IP, subnet, TFTP server IP address, and directory name. When false(2), indicates that the AccessPoint should use locally-configured parameters stored in NVRAM.

etsysR2MgmtCrashUploadServerIP

1.3.6.1.4.1.5624.1.2.11.1.4.2

IpAddress SIZE (4)

DURABLE: The IP address of the TFTP server that should be used for crash dump uploads. This value will be ignored when 'etsysR2MgmtCrashUploadUseBootp' is 'false(2)'.

etsysR2MgmtCrashUploadDirectory

1.3.6.1.4.1.5624.1.2.11.1.4.3

OCTET STRING SIZE (0..128)

DURABLE: The name of the remote directory to which all crash dumps should be uploaded. This value will be ignored when 'etsysR2MgmtCrashUploadUseBootp' is 'false(2)'.

etsysR2MgmtUplineDumpMode

1.3.6.1.4.1.5624.1.2.11.1.4.4

EnabledStatus1 = enabled2 = disabledA simple status value for the object. · Integer32

Determines whether or not a dump file is created on an Access Point crash.

Table details

etsysR2MgmtErrLogTable

1.3.6.1.4.1.5624.1.2.11.1.3.2

Index: etsysR2MgmtErrLogIndex

A table which describes errors encountered by the system.

etsysR2MgmtErrLogIndex

1.3.6.1.4.1.5624.1.2.11.1.3.2.1.1

INTEGER (1..65535) · Integer32

PERSISTENT: The value of this object uniquely identifies an entry in the etsysR2MgmtErrLogTable.

etsysR2MgmtErrLogTimeStamp

1.3.6.1.4.1.5624.1.2.11.1.3.2.1.2

TimeTicks

PERSISTENT: The value of sysUpTime at the time in which the error is logged.

etsysR2MgmtErrLogResetNumber

1.3.6.1.4.1.5624.1.2.11.1.3.2.1.3

INTEGER (1..2147483647) · Integer32

PERSISTENT: The number of resets which have occurred at the time in which the error is logged. (This is the sum of etsysR2MgmtPowerups, etsysR2MgmtMgmtResets, and etsysR2MgmtUnsolicitedResets.)

etsysR2MgmtErrLogInfo

1.3.6.1.4.1.5624.1.2.11.1.3.2.1.4

SnmpAdminStringAn octet string containing administrative information, preferably in human-readable form. To facilitate internationalization, this information is represented using the ISO/IEC IS 10646-1 character set, encoded as an octet string using the UTF-8 transformation format described in [RFC2279]. Since additional code points are added by amendments to the 10646 standard from time to time, implementations must be prepared to encounter any code point from 0x00000000 to 0x7fffffff. Byte sequences that do not correspond to the valid UTF-8 encoding of a code point or are outside this range are prohibited. The use of control codes should be avoided. When it is necessary to represent a newline, the control code sequence CR LF should be used. The use of leading or trailing white space should be avoided. For code points not directly supported by user interface hardware or software, an alternative means of entry and display, such as hexadecimal, may be provided. For information encoded in 7-bit US-ASCII, the UTF-8 encoding is identical to the US-ASCII encoding. UTF-8 may require multiple bytes to represent a single character / code point; thus the length of this object in octets may be different from the number of characters encoded. Similarly, size constraints refer to the number of encoded octets, not the number of characters represented by an encoding. Note that when this TC is used for an object that is used or envisioned to be used as an index, then a SIZE restriction MUST be specified so that the number of sub-identifiers for any object instance does not exceed the limit of 128, as defined by [RFC3416]. Note that the size of an SnmpAdminString object is measured in octets, not characters. SIZE (0..255) · OCTET STRING · hint 255t

PERSISTENT: A textual description of the error being logged.

↑ To TOC