boxServicesNormalTempRangeMin
1.3.6.1.4.1.4526.10.43.1.1
INTEGER (-100..100) · Integer32
Lower boundary of normal temperature range.
2008-02-22
The NETGEAR Private MIB for FASTPATH Box Services Feature.
Download FASTPATH-BOXSERVICES-PRIVATE-MIB.txt Open FASTPATH-BOXSERVICES-PRIVATE-MIB.txt in a new tab
SCALARS (8) · TABLES (3) · TRAPS (3)
| Name | OID |
|---|---|
| boxServicesFansTable | 1.3.6.1.4.1.4526.10.43.1.6 |
| boxServicesPowSuppliesTable | 1.3.6.1.4.1.4526.10.43.1.7 |
| boxServicesTempSensorsTable | 1.3.6.1.4.1.4526.10.43.1.8 |
| Name | OID |
|---|---|
| boxsFanStateChange | 1.3.6.1.4.1.4526.10.43.0.1 |
| boxsPowSupplyStateChange | 1.3.6.1.4.1.4526.10.43.0.2 |
| boxsTemperatureChange | 1.3.6.1.4.1.4526.10.43.0.3 |
END OF TOC
1.3.6.1.4.1.4526.10.43.1.1
INTEGER (-100..100) · Integer32
Lower boundary of normal temperature range.
1.3.6.1.4.1.4526.10.43.1.2
INTEGER (-100..100) · Integer32
Upper boundary of normal temperature range.
1.3.6.1.4.1.4526.10.43.1.3
INTEGER1 = enable2 = disable · Integer32
Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range
1.3.6.1.4.1.4526.10.43.1.4
INTEGER1 = enable2 = disable · Integer32
Enable or disable Power Supply Module state change trap.
1.3.6.1.4.1.4526.10.43.1.5
INTEGER1 = enable2 = disable · Integer32
Enable or disable Fan state change trap.
1.3.6.1.4.1.4526.10.43.1.9
Integer32
The CPLD code version of the unit.
1.3.6.1.4.1.4526.10.43.2.1
INTEGER1 = insertion2 = removal3 = becomeoperational4 = failure · Integer32
This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions
1.3.6.1.4.1.4526.10.43.2.2
INTEGER1 = abovethreshold2 = belowthreshold3 = withinnormalrange · Integer32
This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold)
1.3.6.1.4.1.4526.10.43.1.6
Index: boxServicesFansIndex
Fan
1.3.6.1.4.1.4526.10.43.1.6.1.1
Integer32 (0..2147483647)
Unique index of fan table entry
1.3.6.1.4.1.4526.10.43.1.6.1.2
INTEGER1 = fixed2 = removable · Integer32
The type of fan
1.3.6.1.4.1.4526.10.43.1.6.1.3
INTEGER1 = operational2 = failed3 = powering4 = notpowering5 = notpresent · Integer32
The status of fan
1.3.6.1.4.1.4526.10.43.1.6.1.4
Integer32
The speed of fan
1.3.6.1.4.1.4526.10.43.1.6.1.5
Integer32
The duty level of fan, in percents
1.3.6.1.4.1.4526.10.43.1.7
Index: boxServicesPowSupplyIndex
Power supply
1.3.6.1.4.1.4526.10.43.1.7.1.1
Integer32 (0..2147483647)
Unique index of power supply table entry
1.3.6.1.4.1.4526.10.43.1.7.1.2
INTEGER1 = fixed2 = removable · Integer32
The type of power supply
1.3.6.1.4.1.4526.10.43.1.7.1.3
INTEGER1 = operational2 = failed3 = powering4 = notpowering5 = notpresent · Integer32
The status of power supply
1.3.6.1.4.1.4526.10.43.1.8
Index: boxServicesTempSensorIndex
Temperature sensor
1.3.6.1.4.1.4526.10.43.1.8.1.1
Integer32 (0..2147483647)
Unique index of temperature sensor table entry
1.3.6.1.4.1.4526.10.43.1.8.1.2
INTEGER1 = fixed2 = removable · Integer32
The type of temperature sensor
1.3.6.1.4.1.4526.10.43.1.8.1.3
INTEGER1 = normal2 = warning3 = critical4 = shutdown5 = notpresent6 = notoperational · Integer32
The state of temperature sensor
1.3.6.1.4.1.4526.10.43.1.8.1.4
Integer32
The temperature value reported by sensor
1.3.6.1.4.1.4526.10.43.0.1
Trap is sent when fan state change happens.
1.3.6.1.4.1.4526.10.43.1.6.1.1
Integer32 (0..2147483647)
Unique index of fan table entry
1.3.6.1.4.1.4526.10.43.2.1
INTEGER1 = insertion2 = removal3 = becomeoperational4 = failure · Integer32
This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions
1.3.6.1.4.1.4526.10.43.0.2
Trap is sent when power supply state change happens.
1.3.6.1.4.1.4526.10.43.1.7.1.1
Integer32 (0..2147483647)
Unique index of power supply table entry
1.3.6.1.4.1.4526.10.43.2.1
INTEGER1 = insertion2 = removal3 = becomeoperational4 = failure · Integer32
This event describes states of the fan or power supply. insertion - hot-pluggable fan or power supply was inserted removal - hot-pluggable fan or power supply was removed becomeoperational - fan or power supply became operational after failure state failure - fan or power supply failure happened, i.e. it is not able to perform its functions
1.3.6.1.4.1.4526.10.43.0.3
Trap is sent when temperature is changing and crossing any of the thresholds
1.3.6.1.4.1.4526.10.43.1.8.1.1
Integer32 (0..2147483647)
Unique index of temperature sensor table entry
1.3.6.1.4.1.4526.10.43.2.2
INTEGER1 = abovethreshold2 = belowthreshold3 = withinnormalrange · Integer32
This event describes change of the temperature. To avoid flipping on boundary conditions, it is allowed to send the trap taking into account some margin around thresholds. abovethreshold - temperature increased and crossed upper threshold value belowthreshold - temperature decreased and crossed lower threshold value withinnormalrange - temperature returned to normal range (between threshold)