EZ5 MIB Catalog

FORCES-MIB

2010-03-10

Download FORCES-MIB.txt Open FORCES-MIB.txt in a new tab

This MIB module contains managed object definitions for the ForCES Protocol. Copyright (c) 2010 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info). This version of this MIB module is part of RFC 5813; see the RFC itself for full legal notices.

SCALARS (1) · TABLES (1) · TRAPS (4)

Scalars (1)

NameOID
forcesLatestProtocolVersionSupported1.3.6.1.2.1.187.1.1

Tables (1)

NameOID
forcesAssociationTable1.3.6.1.2.1.187.1.2.1

Traps (4)

NameOID
forcesAssociationEntryUp1.3.6.1.2.1.187.0.1
forcesAssociationEntryDown1.3.6.1.2.1.187.0.2
forcesAssociationEntryUpStats1.3.6.1.2.1.187.0.3
forcesAssociationEntryDownStats1.3.6.1.2.1.187.0.4

END OF TOC

Scalar details

forcesLatestProtocolVersionSupported

1.3.6.1.2.1.187.1.1

ForcesProtocolVersionForCES protocol version number. The version numbers used are defined in the specifications of the respective protocol: 1 - ForCESv1, RFC 5810. (1..255) · Integer32 · hint d

The ForCES protocol version supported by the CE. The current protocol version is 1. Note that the CE must also allow interaction with FEs supporting earlier versions.

Table details

forcesAssociationTable

1.3.6.1.2.1.187.1.2.1

Index: forcesAssociationCEID · forcesAssociationFEID

The (conceptual) table of associations.

forcesAssociationCEID

1.3.6.1.2.1.187.1.2.1.1.1

ForcesIDThe ForCES identifier is a 4-octet quantity. SIZE (4) · OCTET STRING

The ForCES ID of the CE.

forcesAssociationFEID

1.3.6.1.2.1.187.1.2.1.1.2

ForcesIDThe ForCES identifier is a 4-octet quantity. SIZE (4) · OCTET STRING

The ForCES ID of the FE.

forcesAssociationRunningProtocolVersion

1.3.6.1.2.1.187.1.2.1.1.3

ForcesProtocolVersionForCES protocol version number. The version numbers used are defined in the specifications of the respective protocol: 1 - ForCESv1, RFC 5810. (1..255) · Integer32 · hint d

The current ForCES protocol version used in this association. The current protocol version is 1.

forcesAssociationTimeUp

1.3.6.1.2.1.187.1.2.1.1.4

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime at the time this association entered the UP state. If this association started prior to the last initialization of the network subsystem, then this object contains a zero value. This object allows to uniquely identify associations with the same CE and FE IDs.

forcesAssociationTimeDown

1.3.6.1.2.1.187.1.2.1.1.5

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime at the time this association left the UP state.

forcesAssociationHBMsgSent

1.3.6.1.2.1.187.1.2.1.1.6

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many Heartbeat messages have been sent by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationHBMsgReceived

1.3.6.1.2.1.187.1.2.1.1.7

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many Heartbeat messages have been received by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationOperMsgSent

1.3.6.1.2.1.187.1.2.1.1.8

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many messages other than Heartbeat (i.e., Config and Query) have been sent by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationOperMsgReceived

1.3.6.1.2.1.187.1.2.1.1.9

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many messages other than Heartbeat (i.e., Config response, Query response, event notification, and packet redirect) have been received by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationCounterDiscontinuityTime

1.3.6.1.2.1.187.1.2.1.1.10

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime on the most recent occasion at which any one or more of this association's counters suffered a discontinuity. The relevant counters are the specific instances associated with this association of any ZeroBasedCounter32 object contained in the forcesAssociationTable. If no such discontinuities have occurred since the last reinitialization of the local management subsystem, then this object contains a zero value.

Trap details

forcesAssociationEntryUp

1.3.6.1.2.1.187.0.1

This notification is generated as soon as an association enters the UP state. Note that these notifications are not throttled as the CE itself should throttle the setup of associations.

forcesAssociationRunningProtocolVersion

1.3.6.1.2.1.187.1.2.1.1.3

ForcesProtocolVersionForCES protocol version number. The version numbers used are defined in the specifications of the respective protocol: 1 - ForCESv1, RFC 5810. (1..255) · Integer32 · hint d

The current ForCES protocol version used in this association. The current protocol version is 1.

forcesAssociationEntryDown

1.3.6.1.2.1.187.0.2

This notification is generated as soon as an association leaves the UP state. Note that these notifications are not throttled as the CE itself should throttle the setup of associations.

forcesAssociationRunningProtocolVersion

1.3.6.1.2.1.187.1.2.1.1.3

ForcesProtocolVersionForCES protocol version number. The version numbers used are defined in the specifications of the respective protocol: 1 - ForCESv1, RFC 5810. (1..255) · Integer32 · hint d

The current ForCES protocol version used in this association. The current protocol version is 1.

forcesAssociationEntryUpStats

1.3.6.1.2.1.187.0.3

This notification is generated as soon as an association enters the UP state. Note that these notifications are not throttled as the CE itself should throttle the setup of associations.

forcesAssociationRunningProtocolVersion

1.3.6.1.2.1.187.1.2.1.1.3

ForcesProtocolVersionForCES protocol version number. The version numbers used are defined in the specifications of the respective protocol: 1 - ForCESv1, RFC 5810. (1..255) · Integer32 · hint d

The current ForCES protocol version used in this association. The current protocol version is 1.

forcesAssociationTimeUp

1.3.6.1.2.1.187.1.2.1.1.4

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime at the time this association entered the UP state. If this association started prior to the last initialization of the network subsystem, then this object contains a zero value. This object allows to uniquely identify associations with the same CE and FE IDs.

forcesAssociationEntryDownStats

1.3.6.1.2.1.187.0.4

This notification is generated as soon as an association leaves the UP state. Note that these notifications are not throttled as the CE itself should throttle the setup of associations.

forcesAssociationRunningProtocolVersion

1.3.6.1.2.1.187.1.2.1.1.3

ForcesProtocolVersionForCES protocol version number. The version numbers used are defined in the specifications of the respective protocol: 1 - ForCESv1, RFC 5810. (1..255) · Integer32 · hint d

The current ForCES protocol version used in this association. The current protocol version is 1.

forcesAssociationTimeUp

1.3.6.1.2.1.187.1.2.1.1.4

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime at the time this association entered the UP state. If this association started prior to the last initialization of the network subsystem, then this object contains a zero value. This object allows to uniquely identify associations with the same CE and FE IDs.

forcesAssociationTimeDown

1.3.6.1.2.1.187.1.2.1.1.5

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime at the time this association left the UP state.

forcesAssociationHBMsgSent

1.3.6.1.2.1.187.1.2.1.1.6

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many Heartbeat messages have been sent by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationHBMsgReceived

1.3.6.1.2.1.187.1.2.1.1.7

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many Heartbeat messages have been received by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationOperMsgSent

1.3.6.1.2.1.187.1.2.1.1.8

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many messages other than Heartbeat (i.e., Config and Query) have been sent by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationOperMsgReceived

1.3.6.1.2.1.187.1.2.1.1.9

ZeroBasedCounter32This TC describes an object that counts events with the following semantics: objects of this type will be set to zero(0) on creation and will thereafter count appropriate events, wrapping back to zero(0) when the value 2^32 is reached. Provided that an application discovers the new object within the minimum time to wrap, it can use the initial value as a delta since it last polled the table of which this object is part. It is important for a management station to be aware of this minimum time and the actual time between polls, and to discard data if the actual time is too long or there is no defined minimum time. Typically, this TC is used in tables where the INDEX space is constantly changing and/or the TimeFilter mechanism is in use. · Gauge32

A counter of how many messages other than Heartbeat (i.e., Config response, Query response, event notification, and packet redirect) have been received by the CE on this association since the association entered the UP state. Discontinuities in the value of this counter can occur at reinitialization of the management system, and at other times as indicated by the value of forcesAssociationCounterDiscontinuityTime.

forcesAssociationCounterDiscontinuityTime

1.3.6.1.2.1.187.1.2.1.1.10

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime on the most recent occasion at which any one or more of this association's counters suffered a discontinuity. The relevant counters are the specific instances associated with this association of any ZeroBasedCounter32 object contained in the forcesAssociationTable. If no such discontinuities have occurred since the last reinitialization of the local management subsystem, then this object contains a zero value.

↑ To TOC