The objects in this MIB module are used to manage the multi-pair bonded xDSL interfaces using ATM inverse multiplexing, as defined in ITU-T Recommendation G.998.1 (G.Bond/ATM).
This MIB module MUST be used in conjunction with the GBOND-MIB module, common to all G.Bond technologies.
The following references are used throughout this MIB module:
[G.998.1] refers to: ITU-T Recommendation G.998.1: 'ATM-based multi-pair bonding', January 2005.
[TR-159] refers to: Broadband Forum Technical Report: 'Management Framework for xDSL Bonding', December 2008.
Naming Conventions:
ATM - Asynchronous Transfer Mode
BCE - Bonding Channel Entity
BTU - Bonding Terminating Unit
CO - Central Office
CPE - Customer Premises Equipment
GBS - Generic Bonding Sub-layer
GBS-C - Generic Bonding Sub-layer, CO side GBS-R - Generic Bonding Sub-layer, RT (or CPE) side
PM - Performance Monitoring
RT - Remote Terminal
SNR - Signal to Noise Ratio
SES - Severely Errored Seconds
UAS - Unavailable Seconds
Copyright (c) 2013 IETF Trust and the persons identified as authors of the code. All rights reserved.
Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info).
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
g9981PortConfUpDiffDelayTolerance
1.3.6.1.2.1.208.1.1.1.1.1
MilliSecondsRepresents time unit value in milliseconds. (0..2047) · Unsigned32 · hint d · milliseconds
A maximum tolerated upstream differential delay (among the member BCEs) of a G.Bond/ATM port, expressed in ms.
This object is read-write for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read or change this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMAUpDiffDelayTolerance. Reference: [TR-159], Section 5.5.2.5; [G.998.1], Section 11.4.1 (6)
g9981PortConfDnDiffDelayTolerance
1.3.6.1.2.1.208.1.1.1.1.2
MilliSecondsRepresents time unit value in milliseconds. (0..2047) · Unsigned32 · hint d · milliseconds
A maximum tolerated downstream differential delay (among the member BCEs) of a G.Bond/ATM port, expressed in ms.
This object is read-write for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read or change this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMADownDiffDelayTolerance. Reference: [TR-159], Section 5.5.2.6; [G.998.1], Section 11.4.1 (6)
g9981PortConfDiffDelayToleranceExceededEnable
1.3.6.1.2.1.208.1.1.1.1.3
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
Indicates whether g9981UpDiffDelayToleranceExceeded and g9981DnDiffDelayToleranceExceeded notifications should be generated for G.Bond/ATM port.
A value of true(1) indicates that the notifications are enabled. A value of false(2) indicates that the notifications are disabled. This object is read-write for the GBS-C. It is irrelevant for the GBS-R ports -- an attempt to read or change this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMADiffDelayToleranceExceededEnable. Reference: [TR-159], Section 5.5.5.7
g9981PortStatTable
1.3.6.1.2.1.208.1.1.2
Index: ifIndex
This table provides overall status information of G.Bond/ATM ports, complementing the generic status information from the ifTable of the IF-MIB and the gBondFltStatus of the GBOND-MIB. Additional status information about connected BCEs is available from the relevant line MIBs.
This table contains live data from the equipment. As such, it is NOT persistent.
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
g9981PortStatRxLostCells
1.3.6.1.2.1.208.1.1.2.1.1
Counter32 · cells
The number of lost ATM cells detected by the G.Bond/ATM port in the receive direction (e.g., upstream direction for a GBS-C port).
Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime as defined in the IF-MIB.
This object maps to the TR-159 attribute aIMARxLostCells. Reference: [TR-159], Section 5.5.2.1; [G.998.1], Section 11.4.2 (4)
g9981PortStatTxLostCells
1.3.6.1.2.1.208.1.1.2.1.2
Counter32 · cells
The number of lost ATM cells detected by the peer G.Bond/ATM port in the receive direction, i.e., downstream direction for a GBS-C port.
This object is irrelevant for the GBS-R ports -- an attempt to read it MUST be rejected (in the case of SNMP, with the error inconsistentValue).
Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime as defined in the IF-MIB.
This object maps to the TR-159 attribute aIMAPeerRxLostCells. Reference: [TR-159], Section 5.5.2.2; [G.998.1], Section 11.4.2 (4)
g9981PortStatMaxUpDiffDelay
1.3.6.1.2.1.208.1.1.2.1.3
Unsigned32 · 0.1 ms
Current maximum upstream differential delay between all operational BCEs in the G.Bond/ATM bonding group, measured in units of 0.1 ms.
This object is read-only for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMAMaxUpDiffDelay. Reference: [TR-159], Section 5.5.2.3
g9981PortStatMaxDnDiffDelay
1.3.6.1.2.1.208.1.1.2.1.4
Unsigned32 · 0.1 ms
Current maximum downstream differential delay between all operational BCEs in the G.Bond/ATM bonding group, measured in units of 0.1 ms.
This object is read-only for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMAMaxDownDiffDelay. Reference: [TR-159], Section 5.5.2.4
g9981PortPmCurTable
1.3.6.1.2.1.208.1.1.3.1
Index: ifIndex
This table contains current Performance Monitoring information for a G.Bond/ATM port. This table contains live data from the equipment and as such is NOT persistent.
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
g9981PortPmCur15MinValidIntervals
1.3.6.1.2.1.208.1.1.3.1.1.1
HCPerfValidIntervalsThe number of near end intervals for which data was collected. The value of an object with an HCPerfValidIntervals syntax will be 96 unless the measurement was (re-)started within the last 1440 minutes, in which case the value will be the number of complete 15 minute intervals for which the agent has at least some data. In certain cases (e.g., in the case where the agent is a proxy) it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available. (0..96) · Integer32
A read-only number of 15-minute intervals for which the performance data was collected. The value of this object will be 96 or the maximum number of 15-minute history intervals collected by the implementation, unless the measurement was (re)started recently, in which case the value will be the number of complete 15-minute intervals for which there are at least some data. In certain cases, it is possible that some intervals are unavailable. In this case, this object reports the maximum interval number for which data is available.
This object partially maps to the TR-159 attribute aGroupPerf15MinValidIntervals. Reference: [TR-159], Section 5.5.1.32
g9981PortPmCur15MinInvalidIntervals
1.3.6.1.2.1.208.1.1.3.1.1.2
HCPerfInvalidIntervalsThe number of near end intervals for which no data is available. The value of an object with an HCPerfInvalidIntervals syntax will typically be zero except in cases where the data for some intervals are not available (e.g., in proxy situations). (0..96) · Integer32
A read-only number of 15-minute intervals for which the performance data was not always available. The value will typically be zero, except in cases where the data for some intervals are not available.
This object partially maps to the TR-159 attribute aGroupPerf15MinInvalidIntervals. Reference: [TR-159], Section 5.5.1.33
g9981PortPmCur15MinTimeElapsed
1.3.6.1.2.1.208.1.1.3.1.1.3
HCPerfTimeElapsedThe number of seconds that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock or the addition of a leap second, the duration of the current interval exceeds the maximum value, the agent will return the maximum value.
For 15 minute intervals, the range is limited to (0..899). For 24 hour intervals, the range is limited to (0..86399). (0..86399) · Integer32 · seconds
A read-only count of seconds that have elapsed since the beginning of the current 15-minute performance interval.
This object partially maps to the TR-159 attribute aGroupPerfCurr15MinTimeElapsed. Reference: [TR-159], Section 5.5.1.34
g9981PortPmCur15MinRxLostCells
1.3.6.1.2.1.208.1.1.3.1.1.4
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A read-only count of lost ATM cells detected by a G.Bond/ATM port (e.g., the GBS-C) in the receive direction, during the current 15-minute performance history interval.
Note that the total number of lost ATM cells is indicated by the g9981PortStatRxLostCells object.
This object is inhibited during Severely Errored Seconds (SES) or Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.1
g9981PortPmCur15MinTxLostCells
1.3.6.1.2.1.208.1.1.3.1.1.5
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A read-only count of lost ATM cells detected by the peer G.Bond/ATM port (e.g., by the GBS-R for the GBS-C) during the current 15-minute performance history interval.
Note that the total number of lost ATM cells is indicated by the g9981PortStatTxLostCells object.
This object is inhibited during Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.2
g9981PortPmCur15MinUpDiffDelay
1.3.6.1.2.1.208.1.1.3.1.1.6
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum upstream differential delay between all operational BCEs in the GBS-C, measured in units of 0.1 ms, during the current 15-minute performance interval.
Note that the current max upstream differential delay is indicated by the g9981PortStatMaxUpDiffDelay object.
This object is inhibited during Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.3
g9981PortPmCur15MinDnDiffDelay
1.3.6.1.2.1.208.1.1.3.1.1.7
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum downstream differential delay between all operational BCEs in the GBS-C (as perceived by the GBS-R), measured in units of 0.1 ms, during the current 15-minute performance history interval.
Note that the current max downstream differential delay is indicated by the g9981PortStatMaxDnDiffDelay object.
This object is inhibited during Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.4
g9981PortPmCur1DayValidIntervals
1.3.6.1.2.1.208.1.1.3.1.1.8
Unsigned32 (0..7) · days
A read-only number of 1-day intervals for which data was collected. The value of this object will be 7 or the maximum number of 1-day history intervals collected by the implementation, unless the measurement was (re)started recently, in which case the value will be the number of complete 1-day intervals for which there are at least some data. In certain cases, it is possible that some intervals are unavailable. In this case, this object reports the maximum interval number for which data is available. Reference: [TR-159], Section 5.5.1.45
g9981PortPmCur1DayInvalidIntervals
1.3.6.1.2.1.208.1.1.3.1.1.9
Unsigned32 (0..7) · days
A read-only number of 1-day intervals for which data was not always available. The value will typically be zero, except in cases where the data for some intervals are not available. Reference: [TR-159], Section 5.5.1.46
g9981PortPmCur1DayTimeElapsed
1.3.6.1.2.1.208.1.1.3.1.1.10
HCPerfTimeElapsedThe number of seconds that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock or the addition of a leap second, the duration of the current interval exceeds the maximum value, the agent will return the maximum value.
For 15 minute intervals, the range is limited to (0..899). For 24 hour intervals, the range is limited to (0..86399). (0..86399) · Integer32 · seconds
A read-only count of seconds that have elapsed since the beginning of the current 1-day performance interval. Reference: [TR-159], Section 5.5.1.47
g9981PortPmCur1DayRxLostCells
1.3.6.1.2.1.208.1.1.3.1.1.11
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A read-only count of lost ATM cells detected by the G.Bond/ATM port (e.g., the GBS-C) during the current 1-day performance interval.
This object is inhibited during Severely Errored Seconds (SES) and Unavailable Seconds (UAS).
g9981PortPmCur1DayTxLostCells
1.3.6.1.2.1.208.1.1.3.1.1.12
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A read-only count of lost ATM cells detected by the peer G.Bond/ATM port (e.g., by the GBS-R for the GBS-C) during the current 1-day performance history interval.
This object is inhibited during Unavailable Seconds (UAS).
g9981PortPmCur1DayUpDiffDelay
1.3.6.1.2.1.208.1.1.3.1.1.13
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum upstream differential delay between all operational BCEs in the GBS-C, measured in units of 0.1 ms, during the current 1-day performance interval.
This object is inhibited during Unavailable Seconds (UAS).
g9981PortPmCur1DayDnDiffDelay
1.3.6.1.2.1.208.1.1.3.1.1.14
HCPerfCurrentCountA gauge associated with a performance measurement in a current 15 minute measurement interval. The value of an object with an HCPerfCurrentCount syntax starts from zero and is increased when associated events occur, until the end of the 15 minute interval. At that time the value of the gauge is stored in the first 15 minute history interval, and the gauge is restarted at zero. In the case where the agent has no valid data available for the current interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfCurrentCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the object's value also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum downstream differential delay between all operational BCEs in the GBS-C, measured in units of 0.1 ms, during the current 1-day performance interval.
This object is inhibited during Unavailable Seconds (UAS).
g9981PortPm15MinTable
1.3.6.1.2.1.208.1.1.3.2
Index: ifIndex · g9981PortPm15MinIntervalIndex
This table contains historical 15-minute buckets of Performance Monitoring information for a G.Bond/ATM port (a row for each 15-minute interval, up to 96 intervals). Entries in this table MUST be maintained in a persistent manner.
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
g9981PortPm15MinIntervalIndex
1.3.6.1.2.1.208.1.1.3.2.1.1
Unsigned32 (1..96)
Performance data interval number. 1 is the most recent previous interval; interval 96 is 24 hours ago. Intervals 2..96 are OPTIONAL.
This object partially maps to the TR-159 attribute aGroupPerf15MinIntervalNumber. Reference: [TR-159], Section 5.5.1.57
g9981PortPm15MinIntervalMoniTime
1.3.6.1.2.1.208.1.1.3.2.1.2
HCPerfTimeElapsedThe number of seconds that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock or the addition of a leap second, the duration of the current interval exceeds the maximum value, the agent will return the maximum value.
For 15 minute intervals, the range is limited to (0..899). For 24 hour intervals, the range is limited to (0..86399). (0..86399) · Integer32 · seconds
A read-only count of seconds over which the performance data was actually monitored. This value will be the same as the interval duration (900 seconds), except in a situation where performance data could not be collected for any reason.
g9981PortPm15MinIntervalRxLostCells
1.3.6.1.2.1.208.1.1.3.2.1.3
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A read-only count of lost ATM cells detected by a G.Bond/ATM port (e.g., the GBS-C) in the receive direction, during the 15-minute performance history interval.
Note that the total number of lost ATM cells is indicated by the g9981PortStatRxLostCells object.
This object is inhibited during Severely Errored Seconds (SES) or Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.1
g9981PortPm15MinIntervalTxLostCells
1.3.6.1.2.1.208.1.1.3.2.1.4
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A read-only count of lost ATM cells detected by the peer G.Bond/ATM port (e.g., by the GBS-R for the GBS-C) during the 15-minute performance history interval.
Note that the total number of lost ATM cells is indicated by the g9981PortStatTxLostCells object.
This object is inhibited during Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.2
g9981PortPm15MinIntervalUpDiffDelay
1.3.6.1.2.1.208.1.1.3.2.1.5
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum upstream differential delay between all operational BCEs in the GBS, measured in units of 0.1 ms, during the 15-minute performance history interval.
Note that the current max upstream differential delay is indicated by the g9981PortStatMaxUpDiffDelay object.
This object is inhibited during Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.3
g9981PortPm15MinIntervalDnDiffDelay
1.3.6.1.2.1.208.1.1.3.2.1.6
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum downstream differential delay between all operational BCEs in the GBS, as perceived by its peer port, measured in units of 0.1 ms, during the 15-minute performance history interval.
Note that the current max downstream differential delay is indicated by the g9981PortStatMaxDnDiffDelay object.
This object is inhibited during Unavailable Seconds (UAS). Reference: [TR-159], Section 5.5.2.4
g9981PortPm15MinIntervalValid
1.3.6.1.2.1.208.1.1.3.2.1.7
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
A read-only object indicating whether or not this history bucket contains valid data. A valid bucket is reported as true(1) and an invalid bucket as false(2). If this history bucket is invalid, the BTU MUST NOT produce notifications based upon the value of the counters in this bucket. Note that an implementation may decide not to store invalid history buckets in its database. In such a case, this object is not required, as only valid history buckets are available while invalid history buckets are simply not in the database.
This object partially maps to the TR-159 attribute aGroupPerf15MinIntervalValid. Reference: [TR-159], Section 5.5.1.58
g9981PortPm1DayTable
1.3.6.1.2.1.208.1.1.3.3
Index: ifIndex · g9981PortPm1DayIntervalIndex
This table contains historical 1-day buckets of Performance Monitoring information for a G.Bond/ATM port (a row for each 1-day interval, up to 7 intervals). Entries in this table MUST be maintained in a persistent manner.
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
A unique value, greater than zero, for each interface. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
g9981PortPm1DayIntervalIndex
1.3.6.1.2.1.208.1.1.3.3.1.1
Unsigned32 (1..7)
Performance data interval number. 1 is the most recent previous interval; interval 7 is 24 hours ago. Intervals 2..7 are OPTIONAL.
This object partially maps to the TR-159 attribute aGroupPerf1DayIntervalNumber. Reference: [TR-159], Section 5.5.1.62
g9981PortPm1DayIntervalMoniTime
1.3.6.1.2.1.208.1.1.3.3.1.2
HCPerfTimeElapsedThe number of seconds that have elapsed since the beginning of the current measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock or the addition of a leap second, the duration of the current interval exceeds the maximum value, the agent will return the maximum value.
For 15 minute intervals, the range is limited to (0..899). For 24 hour intervals, the range is limited to (0..86399). (0..86399) · Integer32 · seconds
A count of seconds over which the performance data was actually monitored. This value will be the same as the interval duration (86400 seconds), except in a situation where performance data could not be collected for any reason.
This object partially maps to the TR-159 attribute aGroupPerf1DayIntervalMoniSecs. Reference: [TR-159], Section 5.5.1.64
g9981PortPm1DayIntervalRxLostCells
1.3.6.1.2.1.208.1.1.3.3.1.3
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A count of lost ATM cells detected by the G.Bond/ATM port (e.g., the GBS-C) during the 1-day performance history interval.
This object is inhibited during Severely Errored Seconds (SES) and Unavailable Seconds (UAS).
g9981PortPm1DayIntervalTxLostCells
1.3.6.1.2.1.208.1.1.3.3.1.4
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · cells
A count of lost ATM cells detected by the peer G.Bond/ATM port (e.g., by the GBS-R for the GBS-C) during the 1-day performance history interval.
This object is inhibited during Unavailable Seconds (UAS).
g9981PortPm1DayIntervalUpDiffDelay
1.3.6.1.2.1.208.1.1.3.3.1.5
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum upstream differential delay between all operational BCEs in the GBS-C, measured in units of 0.1 ms, during the 1-day performance history interval.
This object is inhibited during Unavailable Seconds (UAS).
g9981PortPm1DayIntervalDnDiffDelay
1.3.6.1.2.1.208.1.1.3.3.1.6
HCPerfIntervalCountA gauge associated with a performance measurement in a previous 15 minute measurement interval. In the case where the agent has no valid data available for a particular interval, the corresponding object instance is not available and upon a retrieval request a corresponding error message shall be returned to indicate that this instance does not exist.
Let X be an object with HCPerfIntervalCount syntax. Let Y be an object with HCPerfCurrentCount syntax. Let Z be an object with HCPerfTotalCount syntax. Then, in a system supporting a history of n intervals with X(1) and X(n) the most and least recent intervals respectively, the following applies at the end of a 15 minute interval:
- discard the value of X(n) - the value of X(i) becomes that of X(i-1) for n >= i > 1 - the value of X(1) becomes that of Y. - the value of Z, if supported, is adjusted.
This count represents a non-negative integer, which may increase or decrease, but shall never exceed 2^64-1 (18446744073709551615 decimal), nor fall below 0. The value of an object with HCPerfIntervalCount syntax assumes its maximum value whenever the underlying count exceeds 2^64-1. If the underlying count subsequently decreases below 2^64-1 (due, e.g., to a retroactive adjustment as a result of entering or exiting unavailable time), then the value of the object also decreases.
Note that this TC is not strictly supported in SMIv2, because the 'always increasing' and 'counter wrap' semantics associated with the Counter64 base type are not preserved. It is possible that management applications which rely solely upon the (Counter64) ASN.1 tag to determine object semantics will mistakenly operate upon objects of this type as they would for Counter64 objects.
This textual convention represents a limited and short- term solution, and may be deprecated as a long term solution is defined and deployed to replace it. (0..18446744073709551615) · Counter64 · 0.1 ms
A read-only value specifying the maximum downstream differential delay between all operational BCEs in the GBS-C, measured in units of 0.1 ms, during the 1-day performance history interval.
This object is inhibited during Unavailable Seconds (UAS).
g9981PortPm1DayIntervalValid
1.3.6.1.2.1.208.1.1.3.3.1.7
TruthValue1 = true2 = falseRepresents a boolean value. · Integer32
A read-only object indicating whether or not this history bucket contains valid data. A valid bucket is reported as true(1) and an invalid bucket as false(2). If this history bucket is invalid, the BTU MUST NOT produce notifications based upon the value of the counters in this bucket. Note that an implementation may decide not to store invalid history buckets in its database. In such a case, this object is not required, as only valid history buckets are available while invalid history buckets are simply not in the database.
This object partially maps to the TR-159 attribute aGroupPerf1DayIntervalValid. Reference: [TR-159], Section 5.5.1.63
Trap details
g9981UpDiffDelayToleranceExceeded
1.3.6.1.2.1.208.1.1.0.1
This notification indicates that the maximum upstream differential delay has exceeded the max upstream differential delay threshold, specified by g9981PortConfUpDiffDelayTolerance.
This notification MAY be sent for the GBS-C ports while the port is 'up', on the crossing event in both directions: from normal (diff. delay is above the threshold) to low (diff. delay equals the threshold or is below it) and from low to normal. This notification is not applicable to the GBS-R ports.
Generation of this notification is controlled by the g9981PortConfDiffDelayToleranceExceededEnable attribute.
This object maps to the TR-159 notification nIMAUpDiffDelayToleranceExceeded. Reference: [TR-159], Section 5.5.2.8
g9981PortConfUpDiffDelayTolerance
1.3.6.1.2.1.208.1.1.1.1.1
MilliSecondsRepresents time unit value in milliseconds. (0..2047) · Unsigned32 · hint d · milliseconds
A maximum tolerated upstream differential delay (among the member BCEs) of a G.Bond/ATM port, expressed in ms.
This object is read-write for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read or change this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMAUpDiffDelayTolerance. Reference: [TR-159], Section 5.5.2.5; [G.998.1], Section 11.4.1 (6)
g9981PortStatMaxUpDiffDelay
1.3.6.1.2.1.208.1.1.2.1.3
Unsigned32 · 0.1 ms
Current maximum upstream differential delay between all operational BCEs in the G.Bond/ATM bonding group, measured in units of 0.1 ms.
This object is read-only for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMAMaxUpDiffDelay. Reference: [TR-159], Section 5.5.2.3
g9981DnDiffDelayToleranceExceeded
1.3.6.1.2.1.208.1.1.0.2
This notification indicates that the maximum downstream differential delay has exceeded the max downstream differential delay threshold, specified by g9981PortConfDnDiffDelayTolerance.
This notification MAY be sent for the GBS-C ports while the port is 'up', on the crossing event in both directions: from normal (diff. delay is above the threshold) to low (diff. delay equals the threshold or is below it) and from low to normal. This notification is not applicable to the GBS-R ports. Generation of this notification is controlled by the g9981PortConfDiffDelayToleranceExceededEnable attribute.
This object maps to the TR-159 notification nIMADownDiffDelayToleranceExceeded. Reference: [TR-159], Section 5.5.2.9
g9981PortConfDnDiffDelayTolerance
1.3.6.1.2.1.208.1.1.1.1.2
MilliSecondsRepresents time unit value in milliseconds. (0..2047) · Unsigned32 · hint d · milliseconds
A maximum tolerated downstream differential delay (among the member BCEs) of a G.Bond/ATM port, expressed in ms.
This object is read-write for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read or change this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMADownDiffDelayTolerance. Reference: [TR-159], Section 5.5.2.6; [G.998.1], Section 11.4.1 (6)
g9981PortStatMaxDnDiffDelay
1.3.6.1.2.1.208.1.1.2.1.4
Unsigned32 · 0.1 ms
Current maximum downstream differential delay between all operational BCEs in the G.Bond/ATM bonding group, measured in units of 0.1 ms.
This object is read-only for the GBS-C ports. It is irrelevant for the GBS-R ports -- an attempt to read this object MUST be rejected (in the case of SNMP, with the error inconsistentValue).
This object maps to the TR-159 attribute aIMAMaxDownDiffDelay. Reference: [TR-159], Section 5.5.2.4