EZ5 MIB Catalog

JUNIPER-MIB

2024-02-06

The MIB modules representing Juniper Networks' implementation of enterprise specific MIBs supported by a single SNMP agent.

Download JUNIPER-MIB.txt Open JUNIPER-MIB.txt in a new tab

SCALARS (11) · TABLES (7) · TRAPS (43)

Scalars (11)

NameOID
jnxBoxClass1.3.6.1.4.1.2636.3.1.1
jnxBoxDescr1.3.6.1.4.1.2636.3.1.2
jnxBoxSerialNo1.3.6.1.4.1.2636.3.1.3
jnxBoxRevision1.3.6.1.4.1.2636.3.1.4
jnxBoxInstalled1.3.6.1.4.1.2636.3.1.5
jnxContentsLastChange1.3.6.1.4.1.2636.3.1.7
jnxLEDLastChange1.3.6.1.4.1.2636.3.1.9
jnxFilledLastChange1.3.6.1.4.1.2636.3.1.11
jnxBoxKernelMemoryUsedPercent1.3.6.1.4.1.2636.3.1.16
jnxBoxSystemDomainType1.3.6.1.4.1.2636.3.1.17
jnxBoxPersonality1.3.6.1.4.1.2636.3.1.18

Tables (7)

NameOID
jnxContainersTable1.3.6.1.4.1.2636.3.1.6
jnxContentsTable1.3.6.1.4.1.2636.3.1.8
jnxLEDTable1.3.6.1.4.1.2636.3.1.10
jnxFilledTable1.3.6.1.4.1.2636.3.1.12
jnxOperatingTable1.3.6.1.4.1.2636.3.1.13
jnxRedundancyTable1.3.6.1.4.1.2636.3.1.14
jnxFruTable1.3.6.1.4.1.2636.3.1.15

Traps (43)

NameOID
jnxPowerSupplyFailure1.3.6.1.4.1.2636.4.1.1
jnxFanFailure1.3.6.1.4.1.2636.4.1.2
jnxOverTemperature1.3.6.1.4.1.2636.4.1.3
jnxRedundancySwitchover1.3.6.1.4.1.2636.4.1.4
jnxFruRemoval1.3.6.1.4.1.2636.4.1.5
jnxFruInsertion1.3.6.1.4.1.2636.4.1.6
jnxFruPowerOff1.3.6.1.4.1.2636.4.1.7
jnxFruPowerOn1.3.6.1.4.1.2636.4.1.8
jnxFruFailed1.3.6.1.4.1.2636.4.1.9
jnxFruOffline1.3.6.1.4.1.2636.4.1.10
jnxFruOnline1.3.6.1.4.1.2636.4.1.11
jnxFruCheck1.3.6.1.4.1.2636.4.1.12
jnxFEBSwitchover1.3.6.1.4.1.2636.4.1.13
jnxHardDiskFailed1.3.6.1.4.1.2636.4.1.14
jnxHardDiskMissing1.3.6.1.4.1.2636.4.1.15
jnxBootFromBackup1.3.6.1.4.1.2636.4.1.16
jnxFmLinkErr1.3.6.1.4.1.2636.4.1.17
jnxFmCellDropErr1.3.6.1.4.1.2636.4.1.18
jnxExtSrcLockLost1.3.6.1.4.1.2636.4.1.19
jnxPlaneOffline1.3.6.1.4.1.2636.4.1.20
jnxPlaneOnline1.3.6.1.4.1.2636.4.1.21
jnxPlaneCheck1.3.6.1.4.1.2636.4.1.22
jnxPlaneFault1.3.6.1.4.1.2636.4.1.23
jnxPowerSupplyInputFailure1.3.6.1.4.1.2636.4.1.24
jnxFmAsicErr1.3.6.1.4.1.2636.4.1.25
jnxMountVarOffHardDiskFailed1.3.6.1.4.1.2636.4.1.26
jnxFmHealthChkErr1.3.6.1.4.1.2636.4.1.27
jnxAlarmPortInput1.3.6.1.4.1.2636.4.1.28
jnxUnsupportedFru1.3.6.1.4.1.2636.4.1.29
jnxDyingGasp1.3.6.1.4.1.2636.4.1.30
jnxPowerSupplyOK1.3.6.1.4.1.2636.4.2.1
jnxFanOK1.3.6.1.4.1.2636.4.2.2
jnxTemperatureOK1.3.6.1.4.1.2636.4.2.3
jnxFruOK1.3.6.1.4.1.2636.4.2.4
jnxExtSrcLockAcquired1.3.6.1.4.1.2636.4.2.5
jnxHardDiskOK1.3.6.1.4.1.2636.4.2.6
jnxPowerSupplyInputOK1.3.6.1.4.1.2636.4.2.7
jnxHmcFatal1.3.6.1.4.1.2636.4.33.1
jnxHmcOK1.3.6.1.4.1.2636.4.34.1
jnxPsePoePdDeviceMgrFault1.3.6.1.4.1.2636.4.35.1
jnxPsePoePdVoltInjFault1.3.6.1.4.1.2636.4.35.2
jnxPsePoePdDeviceMgrOK1.3.6.1.4.1.2636.4.36.1
jnxPsePoePdVoltInjOK1.3.6.1.4.1.2636.4.36.2

END OF TOC

Scalar details

jnxBoxClass

1.3.6.1.4.1.2636.3.1.1

OBJECT IDENTIFIER

The class of the box, indicating which product line the box is about, for example, 'Internet Router'.

jnxBoxDescr

1.3.6.1.4.1.2636.3.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name, model, or detailed description of the box, indicating which product the box is about, for example 'M40'.

jnxBoxSerialNo

1.3.6.1.4.1.2636.3.1.3

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The serial number of this subject, blank if unknown or unavailable.

jnxBoxRevision

1.3.6.1.4.1.2636.3.1.4

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The revision of this subject, blank if unknown or unavailable.

jnxBoxInstalled

1.3.6.1.4.1.2636.3.1.5

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the subject was last installed, up-and-running. Zero if unknown or already up-and-running when the agent was up.

jnxContentsLastChange

1.3.6.1.4.1.2636.3.1.7

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the box contents table last changed. Zero if unknown or already existing when the agent was up.

jnxLEDLastChange

1.3.6.1.4.1.2636.3.1.9

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the box LED table last changed. Zero if unknown or already at that state when the agent was up.

jnxFilledLastChange

1.3.6.1.4.1.2636.3.1.11

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the box filled status table last changed. Zero if unknown or already at that state when the agent was up.

jnxBoxKernelMemoryUsedPercent

1.3.6.1.4.1.2636.3.1.16

Integer32

The percentage of kernel memory used of this subject. 0 if unavailable or inapplicable.

jnxBoxSystemDomainType

1.3.6.1.4.1.2636.3.1.17

INTEGER1 = notApplicable2 = rootSystemDomain3 = protectedSystemDomain · Integer32

The system domain type of this subject, notApplicable will be returned if this feature is not supported.

jnxBoxPersonality

1.3.6.1.4.1.2636.3.1.18

OBJECT IDENTIFIER

The personality of the box, indicating which product line it is currently acting as for example, 'MX40'.

Table details

jnxContainersTable

1.3.6.1.4.1.2636.3.1.6

Index: jnxContainersIndex

A list of containers entries.

jnxContainersIndex

1.3.6.1.4.1.2636.3.1.6.1.1

Integer32 (1..2147483647)

The index for this entry.

jnxContainersView

1.3.6.1.4.1.2636.3.1.6.1.2

Integer32 (1..63)

The view(s) from which the specific container appears. This variable indicates that the specific container is embedded and accessible from the corresponding view(s). The value is a bit map represented as a sum. If multiple bits are set, the specified container(s) are located and accessible from that set of views. The various values representing the bit positions and its corresponding views are: 1 front 2 rear 4 top 8 bottom 16 leftHandSide 32 rightHandSide Note 1: LefHandSide and rightHandSide are referred to based on the view from the front. Note 2: If the specified containers are scattered around various views, the numbering is according to the following sequence: front -> rear -> top -> bottom -> leftHandSide -> rightHandSide For each view plane, the numbering sequence is first from left to right, and then from up to down. Note 3: Even though the value in chassis hardware (e.g. slot number) may be labelled from 0, 1, 2, and up, all the indices in MIB start with 1 (not 0) according to network management convention.

jnxContainersLevel

1.3.6.1.4.1.2636.3.1.6.1.3

Integer32

The abstraction level of the box or chassis. It is enumerated from the outside to the inside, from the outer layer to the inner layer. For example, top level (i.e. level 0) refers to chassis frame, level 1 FPC slot within chassis frame, level 2 PIC space within FPC slot.

jnxContainersWithin

1.3.6.1.4.1.2636.3.1.6.1.4

Integer32

The index of its next higher level container housing this entry. The associated jnxContainersIndex in the jnxContainersTable represents its next higher level container.

jnxContainersType

1.3.6.1.4.1.2636.3.1.6.1.5

OBJECT IDENTIFIER

The type of this container.

jnxContainersDescr

1.3.6.1.4.1.2636.3.1.6.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxContainersCount

1.3.6.1.4.1.2636.3.1.6.1.7

Integer32

The maximum number of containers of this level per container of the next higher level. e.g. if there are six level 2 containers in level 1 container, then jnxContainersCount for level 2 is six.

jnxContentsTable

1.3.6.1.4.1.2636.3.1.8

Index: jnxContentsContainerIndex · jnxContentsL1Index · jnxContentsL2Index · jnxContentsL3Index

A list of contents entries.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsType

1.3.6.1.4.1.2636.3.1.8.1.5

OBJECT IDENTIFIER

The type of this subject. zeroDotZero if unknown.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxContentsSerialNo

1.3.6.1.4.1.2636.3.1.8.1.7

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The serial number of this subject, blank if unknown or unavailable.

jnxContentsRevision

1.3.6.1.4.1.2636.3.1.8.1.8

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The revision of this subject, blank if unknown or unavailable.

jnxContentsInstalled

1.3.6.1.4.1.2636.3.1.8.1.9

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the subject was last installed, up-and-running. Zero if unknown or already up-and-running when the agent was up.

jnxContentsPartNo

1.3.6.1.4.1.2636.3.1.8.1.10

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The part number of this subject, blank if unknown or unavailable.

jnxContentsChassisId

1.3.6.1.4.1.2636.3.1.8.1.11

JnxChassisId1 = unknown2 = singleChassis3 = scc4 = lcc05 = lcc16 = lcc27 = lcc38 = jcs19 = jcs210 = jcs311 = jcs412 = node013 = node114 = sfc015 = sfc116 = sfc217 = sfc318 = sfc419 = lcc420 = lcc521 = lcc622 = lcc723 = lcc824 = lcc925 = lcc1026 = lcc1127 = lcc1228 = lcc1329 = lcc1430 = lcc1531 = member032 = member133 = member234 = member335 = member436 = member537 = member638 = member739 = nodeDevice40 = interconnectDevice41 = controlPlaneDevice42 = directorDevice43 = gnf144 = gnf245 = gnf346 = gnf447 = gnf548 = gnf649 = gnf750 = gnf851 = gnf952 = gnf10Identifies a specific router chassis. · Integer32

Identifies the chassis on which the contents of this row exists.

jnxContentsChassisDescr

1.3.6.1.4.1.2636.3.1.8.1.12

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

A textual description of the chassis on which the contents of this row exists.

jnxContentsChassisCleiCode

1.3.6.1.4.1.2636.3.1.8.1.13

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The clei code of this subject, blank if unknown or unavailable. A CLEI code is an intelligent code that consists of 10 alphanumeric characters with 4 data elements. The first data element is considered the basic code with the first 2 characters indicating the technology or equipment type, and the third and fourth characters denoting the functional sub-category. The second data element represents the features, and its three characters denote functional capabilities or changes. The third data element has one character and denotes a reference to a manufacturer, system ID, specification, or drawing. The fourth data element consists of two characters and contains complementary data. These two characters provide a means of differentiating or providing uniqueness between the eight character CLEI codes by identifying the manufacturing vintage of the product. Names are assigned via procedures defined in [GR485]. The assigned maintenance agent for the CLEI code, Telcordia Technologies, is responsible for assigning certain equipment and other identifiers (e.g., location, manufacturer/supplier) for the telecommunications industry.

jnxContentsModel

1.3.6.1.4.1.2636.3.1.8.1.14

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The FRU model name of this subject, blank if unknown or unavailable.

jnxLEDTable

1.3.6.1.4.1.2636.3.1.10

Index: jnxLEDAssociateTable · jnxLEDAssociateIndex · jnxLEDL1Index · jnxLEDL2Index · jnxLEDL3Index

A list of status entries.

jnxLEDAssociateTable

1.3.6.1.4.1.2636.3.1.10.1.1

INTEGER1 = other2 = jnxContainersTable3 = jnxContentsTable · Integer32

The associated table that this entry is related.

jnxLEDAssociateIndex

1.3.6.1.4.1.2636.3.1.10.1.2

Integer32 (1..2147483647)

The index of the associated table that this entry is related.

jnxLEDL1Index

1.3.6.1.4.1.2636.3.1.10.1.3

Integer32 (0..2147483647)

The level one index of the associated table that this entry is related. Zero if unavailable or inapplicable.

jnxLEDL2Index

1.3.6.1.4.1.2636.3.1.10.1.4

Integer32 (0..2147483647)

The level two index of the associated table that this entry is related. Zero if unavailable or inapplicable.

jnxLEDL3Index

1.3.6.1.4.1.2636.3.1.10.1.5

Integer32 (0..2147483647)

The level three index of the associated table that this entry is related. Zero if unavailable or inapplicable.

jnxLEDOriginator

1.3.6.1.4.1.2636.3.1.10.1.6

OBJECT IDENTIFIER

The originator of the this entry.

jnxLEDDescr

1.3.6.1.4.1.2636.3.1.10.1.7

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxLEDState

1.3.6.1.4.1.2636.3.1.10.1.8

INTEGER1 = other2 = green3 = yellow4 = red5 = blue6 = amber7 = off8 = blinkingGreen9 = blinkingYellow10 = blinkingRed11 = blinkingBlue12 = blinkingAmber · Integer32

The state of the LED indicator.

jnxLEDStateOrdered

1.3.6.1.4.1.2636.3.1.10.1.9

INTEGER1 = blue2 = green3 = amber4 = yellow5 = red6 = other7 = off8 = blinkingBlue9 = blinkingGreen10 = blinkingAmber11 = blinkingYellow12 = blinkingRed · Integer32

The state of the LED indicator. Identical to jnxLEDState, but with enums ordered from 'most operational' to 'least operational' states.

jnxFilledTable

1.3.6.1.4.1.2636.3.1.12

Index: jnxFilledContainerIndex · jnxFilledL1Index · jnxFilledL2Index · jnxFilledL3Index

A list of filled status entries.

jnxFilledContainerIndex

1.3.6.1.4.1.2636.3.1.12.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxFilledL1Index

1.3.6.1.4.1.2636.3.1.12.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxFilledL2Index

1.3.6.1.4.1.2636.3.1.12.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxFilledL3Index

1.3.6.1.4.1.2636.3.1.12.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxFilledDescr

1.3.6.1.4.1.2636.3.1.12.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFilledState

1.3.6.1.4.1.2636.3.1.12.1.6

INTEGER1 = unknown2 = empty3 = filled · Integer32

The filled state of this subject.

jnxFilledChassisId

1.3.6.1.4.1.2636.3.1.12.1.7

JnxChassisId1 = unknown2 = singleChassis3 = scc4 = lcc05 = lcc16 = lcc27 = lcc38 = jcs19 = jcs210 = jcs311 = jcs412 = node013 = node114 = sfc015 = sfc116 = sfc217 = sfc318 = sfc419 = lcc420 = lcc521 = lcc622 = lcc723 = lcc824 = lcc925 = lcc1026 = lcc1127 = lcc1228 = lcc1329 = lcc1430 = lcc1531 = member032 = member133 = member234 = member335 = member436 = member537 = member638 = member739 = nodeDevice40 = interconnectDevice41 = controlPlaneDevice42 = directorDevice43 = gnf144 = gnf245 = gnf346 = gnf447 = gnf548 = gnf649 = gnf750 = gnf851 = gnf952 = gnf10Identifies a specific router chassis. · Integer32

Identifies the chassis on which the contents of this row exists.

jnxFilledChassisDescr

1.3.6.1.4.1.2636.3.1.12.1.8

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

A textual description of the chassis on which the contents of this row exists.

jnxOperatingTable

1.3.6.1.4.1.2636.3.1.13

Index: jnxOperatingContentsIndex · jnxOperatingL1Index · jnxOperatingL2Index · jnxOperatingL3Index

A list of operating status entries.

jnxOperatingContentsIndex

1.3.6.1.4.1.2636.3.1.13.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxOperatingL1Index

1.3.6.1.4.1.2636.3.1.13.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxOperatingL2Index

1.3.6.1.4.1.2636.3.1.13.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxOperatingL3Index

1.3.6.1.4.1.2636.3.1.13.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxOperatingDescr

1.3.6.1.4.1.2636.3.1.13.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxOperatingTemp

1.3.6.1.4.1.2636.3.1.13.1.7

Integer32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxOperatingCPU

1.3.6.1.4.1.2636.3.1.13.1.8

Gauge32

The CPU utilization in percentage of this subject. Zero if unavailable or inapplicable.

jnxOperatingISR

1.3.6.1.4.1.2636.3.1.13.1.9

Gauge32

The CPU utilization in percentage of this subject spending in interrupt service routine (ISR). Zero if unavailable or inapplicable.

jnxOperatingDRAMSize

1.3.6.1.4.1.2636.3.1.13.1.10

Integer32

The DRAM size in bytes of this subject. Zero if unavailable or inapplicable.

jnxOperatingBuffer

1.3.6.1.4.1.2636.3.1.13.1.11

Gauge32

The buffer pool utilization in percentage of this subject. Zero if unavailable or inapplicable.

jnxOperatingHeap

1.3.6.1.4.1.2636.3.1.13.1.12

Gauge32

The heap utilization in percentage of this subject. Zero if unavailable or inapplicable.

jnxOperatingUpTime

1.3.6.1.4.1.2636.3.1.13.1.13

TimeIntervalA period of time, measured in units of 0.01 seconds. (0..2147483647) · Integer32

The time interval in 10-millisecond period that this subject has been up and running. Zero if unavailable or inapplicable.

jnxOperatingLastRestart

1.3.6.1.4.1.2636.3.1.13.1.14

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject last restarted. Zero if unavailable or inapplicable.

jnxOperatingMemory

1.3.6.1.4.1.2636.3.1.13.1.15

Integer32

The installed memory size in Megabytes of this subject. Zero if unavailable or inapplicable.

jnxOperatingStateOrdered

1.3.6.1.4.1.2636.3.1.13.1.16

INTEGER1 = running2 = standby3 = ready4 = runningAtFullSpeed5 = reset6 = down7 = unknown · Integer32

The operating state of this subject. Identical to jnxOperatingState, but with enums ordered from 'most operational' to 'least operational' states.

jnxOperatingChassisId

1.3.6.1.4.1.2636.3.1.13.1.17

JnxChassisId1 = unknown2 = singleChassis3 = scc4 = lcc05 = lcc16 = lcc27 = lcc38 = jcs19 = jcs210 = jcs311 = jcs412 = node013 = node114 = sfc015 = sfc116 = sfc217 = sfc318 = sfc419 = lcc420 = lcc521 = lcc622 = lcc723 = lcc824 = lcc925 = lcc1026 = lcc1127 = lcc1228 = lcc1329 = lcc1430 = lcc1531 = member032 = member133 = member234 = member335 = member436 = member537 = member638 = member739 = nodeDevice40 = interconnectDevice41 = controlPlaneDevice42 = directorDevice43 = gnf144 = gnf245 = gnf346 = gnf447 = gnf548 = gnf649 = gnf750 = gnf851 = gnf952 = gnf10Identifies a specific router chassis. · Integer32

Identifies the chassis on which the contents of this row exists.

jnxOperatingChassisDescr

1.3.6.1.4.1.2636.3.1.13.1.18

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

A textual description of the chassis on which the contents of this row exists.

jnxOperatingRestartTime

1.3.6.1.4.1.2636.3.1.13.1.19

DateAndTimeA date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month 1..12 3 4 day 1..31 4 5 hour 0..23 5 6 minutes 0..59 6 7 seconds 0..60 (use 60 for leap-second) 7 8 deci-seconds 0..9 8 9 direction from UTC '+' / '-' 9 10 hours from UTC* 0..13 10 11 minutes from UTC 0..59 * Notes: - the value of year is in network-byte order - daylight saving time in New Zealand is +13 For example, Tuesday May 26, 1992 at 1:30:15 PM EDT would be displayed as: 1992-5-26,13:30:15.0,-4:0 Note that if only local time is known, then timezone information (fields 8-10) is not present. SIZE (8 | 11) · OCTET STRING · hint 2d-1d-1d,1d:1d:1d.1d,1a1d:1d

The time at which this entity last restarted.

jnxOperating1MinLoadAvg

1.3.6.1.4.1.2636.3.1.13.1.20

Gauge32

The CPU Load Average over the last 1 minutes Here it will be shown as percentage value Zero if unavailable or inapplicable.

jnxOperating5MinLoadAvg

1.3.6.1.4.1.2636.3.1.13.1.21

Gauge32

The CPU Load Average over the last 5 minutes Here it will be shown as percentage value Zero if unavailable or inapplicable.

jnxOperating15MinLoadAvg

1.3.6.1.4.1.2636.3.1.13.1.22

Gauge32

The CPU Load Average over the last 15 minutes Here it will be shown as percentage value Zero if unavailable or inapplicable.

jnxOperating1MinAvgCPU

1.3.6.1.4.1.2636.3.1.13.1.23

Gauge32

The CPU utilization in percentage of this subject averaged over last 1 minutes. Zero if unavailable or inapplicable.

jnxOperating5MinAvgCPU

1.3.6.1.4.1.2636.3.1.13.1.24

Gauge32

The CPU utilization in percentage of this subject averaged over last 5 minutes. Zero if unavailable or inapplicable.

jnxOperating15MinAvgCPU

1.3.6.1.4.1.2636.3.1.13.1.25

Gauge32

The CPU utilization in percentage of this subject averaged over last 15 minutes. Zero if unavailable or inapplicable.

jnxOperatingFRUPower

1.3.6.1.4.1.2636.3.1.13.1.26

Gauge32

The present power of each FRU. Here it will be shown in terms of voltage. Zero if unavailable or inapplicable

jnxOperatingBufferCP

1.3.6.1.4.1.2636.3.1.13.1.27

Gauge32

The buffer pool utilization in percentage of this subject in control plane. Zero if unavailable or inapplicable.

jnxOperatingMemoryCP

1.3.6.1.4.1.2636.3.1.13.1.28

Integer32

The Allocated memory size for control plane in Megabytes. Zero if unavailable or inapplicable.

jnxOperatingBufferExt

1.3.6.1.4.1.2636.3.1.13.1.29

Gauge32

The buffer pool utilization in percentage of this subject. Zero if unavailable or inapplicable. does not include inactive memory as free memory.

jnxOperatingTemperature

1.3.6.1.4.1.2636.3.1.13.1.30

Integer32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxRedundancyTable

1.3.6.1.4.1.2636.3.1.14

Index: jnxRedundancyContentsIndex · jnxRedundancyL1Index · jnxRedundancyL2Index · jnxRedundancyL3Index

A list of redundancy information entries.

jnxRedundancyContentsIndex

1.3.6.1.4.1.2636.3.1.14.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxRedundancyL1Index

1.3.6.1.4.1.2636.3.1.14.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxRedundancyL2Index

1.3.6.1.4.1.2636.3.1.14.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxRedundancyL3Index

1.3.6.1.4.1.2636.3.1.14.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxRedundancyDescr

1.3.6.1.4.1.2636.3.1.14.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxRedundancyConfig

1.3.6.1.4.1.2636.3.1.14.1.6

INTEGER1 = unknown2 = master3 = backup4 = disabled5 = notApplicable · Integer32

The election priority of redundancy configuration for this subject. The value 'notApplicable' means no specific instance is configured to be master or backup; whichever component boots up first becomes a master.

jnxRedundancyState

1.3.6.1.4.1.2636.3.1.14.1.7

INTEGER1 = unknown2 = master3 = backup4 = disabled · Integer32

The current running state for this subject.

jnxRedundancySwitchoverCount

1.3.6.1.4.1.2636.3.1.14.1.8

Counter32

The total number of switchover as perceived by this subject since routing engine is up and running. The switchover is defined as a change in state of jnxRedundancyState from master to backup or vice versa. Its value is reset when the routing engine is reset or rebooted.

jnxRedundancySwitchoverTime

1.3.6.1.4.1.2636.3.1.14.1.9

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the jnxRedundancyState of this subject was last switched over from master to backup or vice versa. Zero if unknown or never switched over since the routing engine is up and running.

jnxRedundancySwitchoverReason

1.3.6.1.4.1.2636.3.1.14.1.10

INTEGER1 = other2 = neverSwitched3 = userSwitched4 = autoSwitched · Integer32

The reason of the last switchover for this subject.

jnxRedundancyKeepaliveHeartbeat

1.3.6.1.4.1.2636.3.1.14.1.11

Integer32

The period of sending keepalive messages between the master and backup subsystems. It is a system-wide preset value in seconds used by internal mastership resolution. Zero if unavailable or inapplicable.

jnxRedundancyKeepaliveTimeout

1.3.6.1.4.1.2636.3.1.14.1.12

Integer32

The timeout period in seconds, by the keepalive watchdog timer, before initiating a switch over to the backup subsystem. Zero if unavailable or inapplicable.

jnxRedundancyKeepaliveElapsed

1.3.6.1.4.1.2636.3.1.14.1.13

Integer32

The elapsed time in seconds by this subject since receiving the last keepalive message from the other subsystems. Zero if unavailable or inapplicable.

jnxRedundancyKeepaliveLoss

1.3.6.1.4.1.2636.3.1.14.1.14

Counter32

The total number of losses on keepalive messages between the master and backup subsystems as perceived by this subject since the system is up and running. Zero if unavailable or inapplicable.

jnxRedundancyChassisId

1.3.6.1.4.1.2636.3.1.14.1.15

JnxChassisId1 = unknown2 = singleChassis3 = scc4 = lcc05 = lcc16 = lcc27 = lcc38 = jcs19 = jcs210 = jcs311 = jcs412 = node013 = node114 = sfc015 = sfc116 = sfc217 = sfc318 = sfc419 = lcc420 = lcc521 = lcc622 = lcc723 = lcc824 = lcc925 = lcc1026 = lcc1127 = lcc1228 = lcc1329 = lcc1430 = lcc1531 = member032 = member133 = member234 = member335 = member436 = member537 = member638 = member739 = nodeDevice40 = interconnectDevice41 = controlPlaneDevice42 = directorDevice43 = gnf144 = gnf245 = gnf346 = gnf447 = gnf548 = gnf649 = gnf750 = gnf851 = gnf952 = gnf10Identifies a specific router chassis. · Integer32

Identifies the chassis on which the contents of this row exists.

jnxRedundancyChassisDescr

1.3.6.1.4.1.2636.3.1.14.1.16

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

A textual description of the chassis on which the contents of this row exists.

jnxFruTable

1.3.6.1.4.1.2636.3.1.15

Index: jnxFruContentsIndex · jnxFruL1Index · jnxFruL2Index · jnxFruL3Index

A list of FRU status entries.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruState

1.3.6.1.4.1.2636.3.1.15.1.8

INTEGER1 = unknown2 = empty3 = present4 = ready5 = announceOnline6 = online7 = anounceOffline8 = offline9 = diagnostic10 = standby11 = fault · Integer32

The current state for this subject.

jnxFruTemp

1.3.6.1.4.1.2636.3.1.15.1.9

Gauge32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxFruOfflineReason

1.3.6.1.4.1.2636.3.1.15.1.10

INTEGER1 = unknown2 = none3 = error4 = noPower5 = configPowerOff6 = configHoldInReset7 = cliCommand8 = buttonPress9 = cliRestart10 = overtempShutdown11 = masterClockDown12 = singleSfmModeChange13 = packetSchedulingModeChange14 = physicalRemoval15 = unresponsiveRestart16 = sonetClockAbsent17 = rddPowerOff18 = majorErrors19 = minorErrors20 = lccHardRestart21 = lccVersionMismatch22 = powerCycle23 = reconnect24 = overvoltage25 = pfeVersionMismatch26 = febRddCfgChange27 = fpcMisconfig28 = fruReconnectFail29 = fruFwddReset30 = fruFebSwitch31 = fruFebOffline32 = fruInServSoftUpgradeError33 = fruChasdPowerRatingExceed34 = fruConfigOffline35 = fruServiceRestartRequest36 = spuResetRequest37 = spuFlowdDown38 = spuSpi4Down39 = spuWatchdogTimeout40 = spuCoreDump41 = fpgaSpi4LinkDown42 = i3Spi4LinkDown43 = cppDisconnect44 = cpuNotBoot45 = spuCoreDumpComplete46 = rstOnSpcSpuFailure47 = softRstOnSpcSpuFailure48 = hwAuthenticationFailure49 = reconnectFpcFail50 = fpcAppFailed51 = fpcKernelCrash52 = spuFlowdDownNoCore53 = spuFlowdCoreDumpIncomplete54 = spuFlowdCoreDumpComplete55 = spuIdpdDownNoCore56 = spuIdpdCoreDumpIncomplete57 = spuIdpdCoreDumpComplete58 = spuCoreDumpIncomplete59 = spuIdpdDown60 = fruPfeReset61 = fruReconnectNotReady62 = fruSfLinkDown63 = fruFabricDown64 = fruAntiCounterfeitRetry65 = fruFPCChassisClusterDisable66 = spuFipsError67 = fruFPCFabricDownOffline68 = febCfgChange69 = routeLocalizationRoleChange70 = fruFpcUnsupported71 = psdVersionMismatch72 = fruResetThresholdExceeded73 = picBounce74 = badVoltage75 = fruFPCReducedFabricBW76 = fruAutoheal77 = builtinPicBounce78 = fruFabricDegraded79 = fruFPCFabricDegradedOffline80 = fruUnsupportedSlot81 = fruRouteLocalizationMisCfg82 = fruTypeConfigMismatch83 = lccModeChanged84 = hwFault85 = fruPICOfflineOnEccErrors86 = fruFpcIncompatible87 = fruFpcFanTrayPEMIncompatible88 = fruUnsupportedFirmware89 = openflowConfigChange90 = fruFpcScbIncompatible91 = fruReUnresponsive92 = hwError93 = fruErrorManagerReqFPCReset94 = fruIncompatibleWithPEM95 = fruIncompatibleWithSIB96 = sibIncompatibleWithOtherSIB97 = fruPfeErrors98 = vpnLocalizationRoleChange99 = fruFpcFanTrayIncompatible100 = fruFpcPEMIncompatible101 = mixedSwitchFabric102 = unsupportedFabric103 = jamConfigError104 = fruFpcHFanTrayIncompatible105 = gnfIsOffline106 = gnfdisconnected107 = fruIncompatibleWithVersion108 = fruInvalidConfig109 = katsPostError110 = katsRuntimeError111 = gnfInitRestart112 = gnfOverlapMac113 = fruOfflinedonFipsConstraints114 = fpcUnsupportedMode115 = fpcFtrayNotVerified116 = fpcPemNotVerified117 = fabricAsicFault118 = flowdCoreStart119 = fruFpcSlcMisconfig120 = fruSfbFanTrayIncompatible121 = fruSfbPEMIncompatible122 = fabricAsicFault2123 = fpcAsicInitFail124 = fpcDeprecated125 = fabricDeprecated126 = reDeprecated · Integer32

The offline reason of this subject.

jnxFruLastPowerOff

1.3.6.1.4.1.2636.3.1.15.1.11

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered off. Zero if unavailable or inapplicable.

jnxFruLastPowerOn

1.3.6.1.4.1.2636.3.1.15.1.12

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered on. Zero if unavailable or inapplicable.

jnxFruPowerUpTime

1.3.6.1.4.1.2636.3.1.15.1.13

TimeIntervalA period of time, measured in units of 0.01 seconds. (0..2147483647) · Integer32

The time interval in 10-millisecond period that this subject has been up and running since the last power on time. Zero if unavailable or inapplicable.

jnxFruChassisId

1.3.6.1.4.1.2636.3.1.15.1.14

JnxChassisId1 = unknown2 = singleChassis3 = scc4 = lcc05 = lcc16 = lcc27 = lcc38 = jcs19 = jcs210 = jcs311 = jcs412 = node013 = node114 = sfc015 = sfc116 = sfc217 = sfc318 = sfc419 = lcc420 = lcc521 = lcc622 = lcc723 = lcc824 = lcc925 = lcc1026 = lcc1127 = lcc1228 = lcc1329 = lcc1430 = lcc1531 = member032 = member133 = member234 = member335 = member436 = member537 = member638 = member739 = nodeDevice40 = interconnectDevice41 = controlPlaneDevice42 = directorDevice43 = gnf144 = gnf245 = gnf346 = gnf447 = gnf548 = gnf649 = gnf750 = gnf851 = gnf952 = gnf10Identifies a specific router chassis. · Integer32

Identifies the chassis on which the contents of this row exists.

jnxFruChassisDescr

1.3.6.1.4.1.2636.3.1.15.1.15

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

A textual description of the chassis on which the contents of this row exists.

jnxFruPsdAssignment

1.3.6.1.4.1.2636.3.1.15.1.16

Integer32 (0..31)

The PSD assignment of this subject. Zero if unavailable or not applicable.

Trap details

jnxPowerSupplyFailure

1.3.6.1.4.1.2636.4.1.1

A jnxPowerSupplyFailure trap signifies that the SNMP entity, acting in an agent role, has detected that the specified power supply in the chassis has been in the failure (bad DC output) condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxFanFailure

1.3.6.1.4.1.2636.4.1.2

A jnxFanFailure trap signifies that the SNMP entity, acting in an agent role, has detected that the specified cooling fan or impeller in the chassis has been in the failure (not spinning) condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxOverTemperature

1.3.6.1.4.1.2636.4.1.3

A jnxOverTemperature trap signifies that the SNMP entity, acting in an agent role, has detected that the specified hardware component in the chassis has experienced over temperature condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingTemp

1.3.6.1.4.1.2636.3.1.13.1.7

Integer32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxOperatingTemperature

1.3.6.1.4.1.2636.3.1.13.1.30

Integer32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxRedundancySwitchover

1.3.6.1.4.1.2636.4.1.4

A jnxRedundancySwitchover trap signifies that the SNMP entity, acting in an agent role, has detected that the specified hardware component in the chassis has experienced a redundancy switchover event defined as a change in state of jnxRedundancyState from master to backup or vice versa.

jnxRedundancyContentsIndex

1.3.6.1.4.1.2636.3.1.14.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxRedundancyL1Index

1.3.6.1.4.1.2636.3.1.14.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxRedundancyL2Index

1.3.6.1.4.1.2636.3.1.14.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxRedundancyL3Index

1.3.6.1.4.1.2636.3.1.14.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxRedundancyDescr

1.3.6.1.4.1.2636.3.1.14.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxRedundancyConfig

1.3.6.1.4.1.2636.3.1.14.1.6

INTEGER1 = unknown2 = master3 = backup4 = disabled5 = notApplicable · Integer32

The election priority of redundancy configuration for this subject. The value 'notApplicable' means no specific instance is configured to be master or backup; whichever component boots up first becomes a master.

jnxRedundancyState

1.3.6.1.4.1.2636.3.1.14.1.7

INTEGER1 = unknown2 = master3 = backup4 = disabled · Integer32

The current running state for this subject.

jnxRedundancySwitchoverCount

1.3.6.1.4.1.2636.3.1.14.1.8

Counter32

The total number of switchover as perceived by this subject since routing engine is up and running. The switchover is defined as a change in state of jnxRedundancyState from master to backup or vice versa. Its value is reset when the routing engine is reset or rebooted.

jnxRedundancySwitchoverTime

1.3.6.1.4.1.2636.3.1.14.1.9

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when the jnxRedundancyState of this subject was last switched over from master to backup or vice versa. Zero if unknown or never switched over since the routing engine is up and running.

jnxRedundancySwitchoverReason

1.3.6.1.4.1.2636.3.1.14.1.10

INTEGER1 = other2 = neverSwitched3 = userSwitched4 = autoSwitched · Integer32

The reason of the last switchover for this subject.

jnxFruRemoval

1.3.6.1.4.1.2636.4.1.5

A jnxFruRemoval trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has been removed from the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruInsertion

1.3.6.1.4.1.2636.4.1.6

A jnxFruInsertion trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has been inserted into the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruPowerOff

1.3.6.1.4.1.2636.4.1.7

A jnxFruPowerOff trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has been powered off in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruOfflineReason

1.3.6.1.4.1.2636.3.1.15.1.10

INTEGER1 = unknown2 = none3 = error4 = noPower5 = configPowerOff6 = configHoldInReset7 = cliCommand8 = buttonPress9 = cliRestart10 = overtempShutdown11 = masterClockDown12 = singleSfmModeChange13 = packetSchedulingModeChange14 = physicalRemoval15 = unresponsiveRestart16 = sonetClockAbsent17 = rddPowerOff18 = majorErrors19 = minorErrors20 = lccHardRestart21 = lccVersionMismatch22 = powerCycle23 = reconnect24 = overvoltage25 = pfeVersionMismatch26 = febRddCfgChange27 = fpcMisconfig28 = fruReconnectFail29 = fruFwddReset30 = fruFebSwitch31 = fruFebOffline32 = fruInServSoftUpgradeError33 = fruChasdPowerRatingExceed34 = fruConfigOffline35 = fruServiceRestartRequest36 = spuResetRequest37 = spuFlowdDown38 = spuSpi4Down39 = spuWatchdogTimeout40 = spuCoreDump41 = fpgaSpi4LinkDown42 = i3Spi4LinkDown43 = cppDisconnect44 = cpuNotBoot45 = spuCoreDumpComplete46 = rstOnSpcSpuFailure47 = softRstOnSpcSpuFailure48 = hwAuthenticationFailure49 = reconnectFpcFail50 = fpcAppFailed51 = fpcKernelCrash52 = spuFlowdDownNoCore53 = spuFlowdCoreDumpIncomplete54 = spuFlowdCoreDumpComplete55 = spuIdpdDownNoCore56 = spuIdpdCoreDumpIncomplete57 = spuIdpdCoreDumpComplete58 = spuCoreDumpIncomplete59 = spuIdpdDown60 = fruPfeReset61 = fruReconnectNotReady62 = fruSfLinkDown63 = fruFabricDown64 = fruAntiCounterfeitRetry65 = fruFPCChassisClusterDisable66 = spuFipsError67 = fruFPCFabricDownOffline68 = febCfgChange69 = routeLocalizationRoleChange70 = fruFpcUnsupported71 = psdVersionMismatch72 = fruResetThresholdExceeded73 = picBounce74 = badVoltage75 = fruFPCReducedFabricBW76 = fruAutoheal77 = builtinPicBounce78 = fruFabricDegraded79 = fruFPCFabricDegradedOffline80 = fruUnsupportedSlot81 = fruRouteLocalizationMisCfg82 = fruTypeConfigMismatch83 = lccModeChanged84 = hwFault85 = fruPICOfflineOnEccErrors86 = fruFpcIncompatible87 = fruFpcFanTrayPEMIncompatible88 = fruUnsupportedFirmware89 = openflowConfigChange90 = fruFpcScbIncompatible91 = fruReUnresponsive92 = hwError93 = fruErrorManagerReqFPCReset94 = fruIncompatibleWithPEM95 = fruIncompatibleWithSIB96 = sibIncompatibleWithOtherSIB97 = fruPfeErrors98 = vpnLocalizationRoleChange99 = fruFpcFanTrayIncompatible100 = fruFpcPEMIncompatible101 = mixedSwitchFabric102 = unsupportedFabric103 = jamConfigError104 = fruFpcHFanTrayIncompatible105 = gnfIsOffline106 = gnfdisconnected107 = fruIncompatibleWithVersion108 = fruInvalidConfig109 = katsPostError110 = katsRuntimeError111 = gnfInitRestart112 = gnfOverlapMac113 = fruOfflinedonFipsConstraints114 = fpcUnsupportedMode115 = fpcFtrayNotVerified116 = fpcPemNotVerified117 = fabricAsicFault118 = flowdCoreStart119 = fruFpcSlcMisconfig120 = fruSfbFanTrayIncompatible121 = fruSfbPEMIncompatible122 = fabricAsicFault2123 = fpcAsicInitFail124 = fpcDeprecated125 = fabricDeprecated126 = reDeprecated · Integer32

The offline reason of this subject.

jnxFruLastPowerOff

1.3.6.1.4.1.2636.3.1.15.1.11

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered off. Zero if unavailable or inapplicable.

jnxFruLastPowerOn

1.3.6.1.4.1.2636.3.1.15.1.12

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered on. Zero if unavailable or inapplicable.

jnxFruPowerOn

1.3.6.1.4.1.2636.4.1.8

A jnxFruPowerOn trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has been powered on in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruOfflineReason

1.3.6.1.4.1.2636.3.1.15.1.10

INTEGER1 = unknown2 = none3 = error4 = noPower5 = configPowerOff6 = configHoldInReset7 = cliCommand8 = buttonPress9 = cliRestart10 = overtempShutdown11 = masterClockDown12 = singleSfmModeChange13 = packetSchedulingModeChange14 = physicalRemoval15 = unresponsiveRestart16 = sonetClockAbsent17 = rddPowerOff18 = majorErrors19 = minorErrors20 = lccHardRestart21 = lccVersionMismatch22 = powerCycle23 = reconnect24 = overvoltage25 = pfeVersionMismatch26 = febRddCfgChange27 = fpcMisconfig28 = fruReconnectFail29 = fruFwddReset30 = fruFebSwitch31 = fruFebOffline32 = fruInServSoftUpgradeError33 = fruChasdPowerRatingExceed34 = fruConfigOffline35 = fruServiceRestartRequest36 = spuResetRequest37 = spuFlowdDown38 = spuSpi4Down39 = spuWatchdogTimeout40 = spuCoreDump41 = fpgaSpi4LinkDown42 = i3Spi4LinkDown43 = cppDisconnect44 = cpuNotBoot45 = spuCoreDumpComplete46 = rstOnSpcSpuFailure47 = softRstOnSpcSpuFailure48 = hwAuthenticationFailure49 = reconnectFpcFail50 = fpcAppFailed51 = fpcKernelCrash52 = spuFlowdDownNoCore53 = spuFlowdCoreDumpIncomplete54 = spuFlowdCoreDumpComplete55 = spuIdpdDownNoCore56 = spuIdpdCoreDumpIncomplete57 = spuIdpdCoreDumpComplete58 = spuCoreDumpIncomplete59 = spuIdpdDown60 = fruPfeReset61 = fruReconnectNotReady62 = fruSfLinkDown63 = fruFabricDown64 = fruAntiCounterfeitRetry65 = fruFPCChassisClusterDisable66 = spuFipsError67 = fruFPCFabricDownOffline68 = febCfgChange69 = routeLocalizationRoleChange70 = fruFpcUnsupported71 = psdVersionMismatch72 = fruResetThresholdExceeded73 = picBounce74 = badVoltage75 = fruFPCReducedFabricBW76 = fruAutoheal77 = builtinPicBounce78 = fruFabricDegraded79 = fruFPCFabricDegradedOffline80 = fruUnsupportedSlot81 = fruRouteLocalizationMisCfg82 = fruTypeConfigMismatch83 = lccModeChanged84 = hwFault85 = fruPICOfflineOnEccErrors86 = fruFpcIncompatible87 = fruFpcFanTrayPEMIncompatible88 = fruUnsupportedFirmware89 = openflowConfigChange90 = fruFpcScbIncompatible91 = fruReUnresponsive92 = hwError93 = fruErrorManagerReqFPCReset94 = fruIncompatibleWithPEM95 = fruIncompatibleWithSIB96 = sibIncompatibleWithOtherSIB97 = fruPfeErrors98 = vpnLocalizationRoleChange99 = fruFpcFanTrayIncompatible100 = fruFpcPEMIncompatible101 = mixedSwitchFabric102 = unsupportedFabric103 = jamConfigError104 = fruFpcHFanTrayIncompatible105 = gnfIsOffline106 = gnfdisconnected107 = fruIncompatibleWithVersion108 = fruInvalidConfig109 = katsPostError110 = katsRuntimeError111 = gnfInitRestart112 = gnfOverlapMac113 = fruOfflinedonFipsConstraints114 = fpcUnsupportedMode115 = fpcFtrayNotVerified116 = fpcPemNotVerified117 = fabricAsicFault118 = flowdCoreStart119 = fruFpcSlcMisconfig120 = fruSfbFanTrayIncompatible121 = fruSfbPEMIncompatible122 = fabricAsicFault2123 = fpcAsicInitFail124 = fpcDeprecated125 = fabricDeprecated126 = reDeprecated · Integer32

The offline reason of this subject.

jnxFruLastPowerOff

1.3.6.1.4.1.2636.3.1.15.1.11

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered off. Zero if unavailable or inapplicable.

jnxFruLastPowerOn

1.3.6.1.4.1.2636.3.1.15.1.12

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered on. Zero if unavailable or inapplicable.

jnxFruFailed

1.3.6.1.4.1.2636.4.1.9

This indicates the specified FRU (Field Replaceable Unit) has failed in the chassis. Most probably this is due toi some hard error such as fru is not powering up or not able to load ukernel. In these cases, fru is replaced.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruOffline

1.3.6.1.4.1.2636.4.1.10

A jnxFruOffline trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has gone offline in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruOfflineReason

1.3.6.1.4.1.2636.3.1.15.1.10

INTEGER1 = unknown2 = none3 = error4 = noPower5 = configPowerOff6 = configHoldInReset7 = cliCommand8 = buttonPress9 = cliRestart10 = overtempShutdown11 = masterClockDown12 = singleSfmModeChange13 = packetSchedulingModeChange14 = physicalRemoval15 = unresponsiveRestart16 = sonetClockAbsent17 = rddPowerOff18 = majorErrors19 = minorErrors20 = lccHardRestart21 = lccVersionMismatch22 = powerCycle23 = reconnect24 = overvoltage25 = pfeVersionMismatch26 = febRddCfgChange27 = fpcMisconfig28 = fruReconnectFail29 = fruFwddReset30 = fruFebSwitch31 = fruFebOffline32 = fruInServSoftUpgradeError33 = fruChasdPowerRatingExceed34 = fruConfigOffline35 = fruServiceRestartRequest36 = spuResetRequest37 = spuFlowdDown38 = spuSpi4Down39 = spuWatchdogTimeout40 = spuCoreDump41 = fpgaSpi4LinkDown42 = i3Spi4LinkDown43 = cppDisconnect44 = cpuNotBoot45 = spuCoreDumpComplete46 = rstOnSpcSpuFailure47 = softRstOnSpcSpuFailure48 = hwAuthenticationFailure49 = reconnectFpcFail50 = fpcAppFailed51 = fpcKernelCrash52 = spuFlowdDownNoCore53 = spuFlowdCoreDumpIncomplete54 = spuFlowdCoreDumpComplete55 = spuIdpdDownNoCore56 = spuIdpdCoreDumpIncomplete57 = spuIdpdCoreDumpComplete58 = spuCoreDumpIncomplete59 = spuIdpdDown60 = fruPfeReset61 = fruReconnectNotReady62 = fruSfLinkDown63 = fruFabricDown64 = fruAntiCounterfeitRetry65 = fruFPCChassisClusterDisable66 = spuFipsError67 = fruFPCFabricDownOffline68 = febCfgChange69 = routeLocalizationRoleChange70 = fruFpcUnsupported71 = psdVersionMismatch72 = fruResetThresholdExceeded73 = picBounce74 = badVoltage75 = fruFPCReducedFabricBW76 = fruAutoheal77 = builtinPicBounce78 = fruFabricDegraded79 = fruFPCFabricDegradedOffline80 = fruUnsupportedSlot81 = fruRouteLocalizationMisCfg82 = fruTypeConfigMismatch83 = lccModeChanged84 = hwFault85 = fruPICOfflineOnEccErrors86 = fruFpcIncompatible87 = fruFpcFanTrayPEMIncompatible88 = fruUnsupportedFirmware89 = openflowConfigChange90 = fruFpcScbIncompatible91 = fruReUnresponsive92 = hwError93 = fruErrorManagerReqFPCReset94 = fruIncompatibleWithPEM95 = fruIncompatibleWithSIB96 = sibIncompatibleWithOtherSIB97 = fruPfeErrors98 = vpnLocalizationRoleChange99 = fruFpcFanTrayIncompatible100 = fruFpcPEMIncompatible101 = mixedSwitchFabric102 = unsupportedFabric103 = jamConfigError104 = fruFpcHFanTrayIncompatible105 = gnfIsOffline106 = gnfdisconnected107 = fruIncompatibleWithVersion108 = fruInvalidConfig109 = katsPostError110 = katsRuntimeError111 = gnfInitRestart112 = gnfOverlapMac113 = fruOfflinedonFipsConstraints114 = fpcUnsupportedMode115 = fpcFtrayNotVerified116 = fpcPemNotVerified117 = fabricAsicFault118 = flowdCoreStart119 = fruFpcSlcMisconfig120 = fruSfbFanTrayIncompatible121 = fruSfbPEMIncompatible122 = fabricAsicFault2123 = fpcAsicInitFail124 = fpcDeprecated125 = fabricDeprecated126 = reDeprecated · Integer32

The offline reason of this subject.

jnxFruLastPowerOff

1.3.6.1.4.1.2636.3.1.15.1.11

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered off. Zero if unavailable or inapplicable.

jnxFruLastPowerOn

1.3.6.1.4.1.2636.3.1.15.1.12

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered on. Zero if unavailable or inapplicable.

jnxFruOnline

1.3.6.1.4.1.2636.4.1.11

A jnxFruOnline trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has gone online in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruCheck

1.3.6.1.4.1.2636.4.1.12

A jnxFruCheck trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has encountered some operational errors and gone into check state in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFEBSwitchover

1.3.6.1.4.1.2636.4.1.13

A jnxFEBSwitchover trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FEB (Forwarding Engine Board) has switched over.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxHardDiskFailed

1.3.6.1.4.1.2636.4.1.14

A jnxHardDiskFailed trap signifies that the SNMP entity, acting in an agent role, has detected that the Disk in the specified Routing Engine has encountered some operational errors and gone into failed state in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxHardDiskMissing

1.3.6.1.4.1.2636.4.1.15

A DiskMissing trap signifies that the SNMP entity, acting in an agent role, has detected that hard disk in the specified outing Engine is missing from boot device list.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxBootFromBackup

1.3.6.1.4.1.2636.4.1.16

A jnxBootFromBackup trap signifies that the SNMP entity, acting in an agent role, has detected that the specified routing-engine/member has booted from the back up root partition

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFmLinkErr

1.3.6.1.4.1.2636.4.1.17

A LinkErr trap signifies that the SNMP entity, acting in an agent role, has detected link errors.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFmCellDropErr

1.3.6.1.4.1.2636.4.1.18

A CellDropErr trap signifies that the SNMP entity, acting in an agent role, has detected cell drop errors.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxExtSrcLockLost

1.3.6.1.4.1.2636.4.1.19

A ExtSrcLockLost trap signifies that the SNMP entity, acting in an agent role, has detected that a lock for an external clock source has been lost.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxPlaneOffline

1.3.6.1.4.1.2636.4.1.20

A jnxPlaneOffline trap signifies that the SNMP entity, acting in an agent role, has detected that the specified Fabric plane has gone offline in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFruOfflineReason

1.3.6.1.4.1.2636.3.1.15.1.10

INTEGER1 = unknown2 = none3 = error4 = noPower5 = configPowerOff6 = configHoldInReset7 = cliCommand8 = buttonPress9 = cliRestart10 = overtempShutdown11 = masterClockDown12 = singleSfmModeChange13 = packetSchedulingModeChange14 = physicalRemoval15 = unresponsiveRestart16 = sonetClockAbsent17 = rddPowerOff18 = majorErrors19 = minorErrors20 = lccHardRestart21 = lccVersionMismatch22 = powerCycle23 = reconnect24 = overvoltage25 = pfeVersionMismatch26 = febRddCfgChange27 = fpcMisconfig28 = fruReconnectFail29 = fruFwddReset30 = fruFebSwitch31 = fruFebOffline32 = fruInServSoftUpgradeError33 = fruChasdPowerRatingExceed34 = fruConfigOffline35 = fruServiceRestartRequest36 = spuResetRequest37 = spuFlowdDown38 = spuSpi4Down39 = spuWatchdogTimeout40 = spuCoreDump41 = fpgaSpi4LinkDown42 = i3Spi4LinkDown43 = cppDisconnect44 = cpuNotBoot45 = spuCoreDumpComplete46 = rstOnSpcSpuFailure47 = softRstOnSpcSpuFailure48 = hwAuthenticationFailure49 = reconnectFpcFail50 = fpcAppFailed51 = fpcKernelCrash52 = spuFlowdDownNoCore53 = spuFlowdCoreDumpIncomplete54 = spuFlowdCoreDumpComplete55 = spuIdpdDownNoCore56 = spuIdpdCoreDumpIncomplete57 = spuIdpdCoreDumpComplete58 = spuCoreDumpIncomplete59 = spuIdpdDown60 = fruPfeReset61 = fruReconnectNotReady62 = fruSfLinkDown63 = fruFabricDown64 = fruAntiCounterfeitRetry65 = fruFPCChassisClusterDisable66 = spuFipsError67 = fruFPCFabricDownOffline68 = febCfgChange69 = routeLocalizationRoleChange70 = fruFpcUnsupported71 = psdVersionMismatch72 = fruResetThresholdExceeded73 = picBounce74 = badVoltage75 = fruFPCReducedFabricBW76 = fruAutoheal77 = builtinPicBounce78 = fruFabricDegraded79 = fruFPCFabricDegradedOffline80 = fruUnsupportedSlot81 = fruRouteLocalizationMisCfg82 = fruTypeConfigMismatch83 = lccModeChanged84 = hwFault85 = fruPICOfflineOnEccErrors86 = fruFpcIncompatible87 = fruFpcFanTrayPEMIncompatible88 = fruUnsupportedFirmware89 = openflowConfigChange90 = fruFpcScbIncompatible91 = fruReUnresponsive92 = hwError93 = fruErrorManagerReqFPCReset94 = fruIncompatibleWithPEM95 = fruIncompatibleWithSIB96 = sibIncompatibleWithOtherSIB97 = fruPfeErrors98 = vpnLocalizationRoleChange99 = fruFpcFanTrayIncompatible100 = fruFpcPEMIncompatible101 = mixedSwitchFabric102 = unsupportedFabric103 = jamConfigError104 = fruFpcHFanTrayIncompatible105 = gnfIsOffline106 = gnfdisconnected107 = fruIncompatibleWithVersion108 = fruInvalidConfig109 = katsPostError110 = katsRuntimeError111 = gnfInitRestart112 = gnfOverlapMac113 = fruOfflinedonFipsConstraints114 = fpcUnsupportedMode115 = fpcFtrayNotVerified116 = fpcPemNotVerified117 = fabricAsicFault118 = flowdCoreStart119 = fruFpcSlcMisconfig120 = fruSfbFanTrayIncompatible121 = fruSfbPEMIncompatible122 = fabricAsicFault2123 = fpcAsicInitFail124 = fpcDeprecated125 = fabricDeprecated126 = reDeprecated · Integer32

The offline reason of this subject.

jnxFruLastPowerOff

1.3.6.1.4.1.2636.3.1.15.1.11

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered off. Zero if unavailable or inapplicable.

jnxFruLastPowerOn

1.3.6.1.4.1.2636.3.1.15.1.12

TimeStampThe value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset to zero as a result of a re- initialization of the network management (sub)system, then the values of all TimeStamp objects are also reset. However, after approximately 497 days without a re- initialization, the sysUpTime object will reach 2^^32-1 and then increment around to zero; in this case, existing values of TimeStamp objects do not change. This can lead to ambiguities in the value of TimeStamp objects. · TimeTicks

The value of sysUpTime when this subject was last powered on. Zero if unavailable or inapplicable.

jnxPlaneOnline

1.3.6.1.4.1.2636.4.1.21

A jnxPlaneOnline trap signifies that the SNMP entity, acting in an agent role, has detected that the specified Fabric Plane has gone online in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxPlaneCheck

1.3.6.1.4.1.2636.4.1.22

A jnxPlaneCheck trap signifies that the SNMP entity, acting in an agent role, has detected that the specified Fabric plane has encountered some operational errors and gone into check state in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxPlaneFault

1.3.6.1.4.1.2636.4.1.23

A jnxPlaneCheck trap signifies that the SNMP entity, acting in an agent role, has detected that the specified Fabric plane has encountered some operational errors and gone into fault state in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxPowerSupplyInputFailure

1.3.6.1.4.1.2636.4.1.24

A jnxPowerSupplyInputFailure trap signifies that the SNMP entity, acting in an agent role, has detected that the specified power supply's input feed in the chassis has been in the failure condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxFmAsicErr

1.3.6.1.4.1.2636.4.1.25

A jnxFmAsicErr trap signifies that the SNMP entity, acting in an agent role, has detected errors in a switching device within the fabric.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxMountVarOffHardDiskFailed

1.3.6.1.4.1.2636.4.1.26

A jnxMountVarOffHardDiskFailed signifies that the SNMP entity, acting in an agent role, has detected that mount of /var failed off harddisk, emergency /var created.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxFmHealthChkErr

1.3.6.1.4.1.2636.4.1.27

A HealthChkErr trap signifies that the SNMP entity, acting in an agent role, has detected health check errors.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxAlarmPortInput

1.3.6.1.4.1.2636.4.1.28

A AlarmPortInput trap signifies that the SNMP entity, acting in an agent role, has detected input alarm port errors.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxUnsupportedFru

1.3.6.1.4.1.2636.4.1.29

A jnxUnsupportedFru trap signifies that the SNMP entity, acting in an agent role, has detected that the Unsupported Fru has been inserted in the chassis

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxDyingGasp

1.3.6.1.4.1.2636.4.1.30

jnxDyingGasp trap signifies that system is going down due to power failure.

jnxPowerSupplyOK

1.3.6.1.4.1.2636.4.2.1

A jnxPowerSupplyOK trap signifies that the SNMP entity, acting in an agent role, has detected that the specified power supply in the chassis has recovered from the failure (bad DC output) condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxFanOK

1.3.6.1.4.1.2636.4.2.2

A jnxFanOK trap signifies that the SNMP entity, acting in an agent role, has detected that the specified cooling fan or impeller in the chassis has recovered from the failure (not spinning) condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxTemperatureOK

1.3.6.1.4.1.2636.4.2.3

A jnxTemperatureOK trap signifies that the SNMP entity, acting in an agent role, has detected that the specified hardware component in the chassis has recovered from over temperature condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingTemp

1.3.6.1.4.1.2636.3.1.13.1.7

Integer32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxOperatingTemperature

1.3.6.1.4.1.2636.3.1.13.1.30

Integer32

The temperature in Celsius (degrees C) of this subject. Zero if unavailable or inapplicable.

jnxFruOK

1.3.6.1.4.1.2636.4.2.4

A jnxFruOK trap signifies that the SNMP entity, acting in an agent role, has detected that the specified FRU (Field Replaceable Unit) has recovered from previous operational errors and it is in ok state in the chassis.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxExtSrcLockAcquired

1.3.6.1.4.1.2636.4.2.5

A ExtSrcLockAcquired trap signifies that the SNMP entity, acting in an agent role, has detected that a lock for an external clock source has been acquired.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxHardDiskOK

1.3.6.1.4.1.2636.4.2.6

A jnxHardDiskOK trap signifies that the SNMP entity, acting in an agent role, has detected that the Disk in the specified Routing Engine has recovered from the failure condition.

jnxFruContentsIndex

1.3.6.1.4.1.2636.3.1.15.1.1

Integer32 (1..2147483647)

The associated jnxContentsContainerIndex in the jnxContentsTable.

jnxFruL1Index

1.3.6.1.4.1.2636.3.1.15.1.2

Integer32 (0..2147483647)

The level one index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL2Index

1.3.6.1.4.1.2636.3.1.15.1.3

Integer32 (0..2147483647)

The level two index associated with this subject. Zero if unavailable or inapplicable.

jnxFruL3Index

1.3.6.1.4.1.2636.3.1.15.1.4

Integer32 (0..2147483647)

The level three index associated with this subject. Zero if unavailable or inapplicable.

jnxFruName

1.3.6.1.4.1.2636.3.1.15.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxFruType

1.3.6.1.4.1.2636.3.1.15.1.6

INTEGER1 = other2 = clockGenerator3 = flexiblePicConcentrator4 = switchingAndForwardingModule5 = controlBoard6 = routingEngine7 = powerEntryModule8 = frontPanelModule9 = switchInterfaceBoard10 = processorMezzanineBoardForSIB11 = portInterfaceCard12 = craftInterfacePanel13 = fan14 = lineCardChassis15 = forwardingEngineBoard16 = protectedSystemDomain17 = powerDistributionUnit18 = powerSupplyModule19 = switchFabricBoard20 = adapterCard21 = ftc22 = tib · Integer32

The FRU type for this subject.

jnxFruSlot

1.3.6.1.4.1.2636.3.1.15.1.7

Integer32 (0..2147483647)

The slot number of this subject. This is equivalent to jnxFruL1Index in meaning. Zero if unavailable or inapplicable.

jnxPowerSupplyInputOK

1.3.6.1.4.1.2636.4.2.7

A jnxPowerSupplyInputOK trap signifies that the SNMP entity, acting in an agent role, has detected that the specified power supply's input feed in the chassis has recovered from the failure condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxHmcFatal

1.3.6.1.4.1.2636.4.33.1

A jnxHmcFatal trap signifies that the SNMP entity, acting in an agent role, has detected that the specified HMC on a specific FPC has been in the failure condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxHmcOK

1.3.6.1.4.1.2636.4.34.1

A jnxHmcOK trap signifies that the SNMP entity, acting in an agent role, has detected that the specified HMC on a specific FPC has recovered from the failure (Fatal error) condition.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxOperatingState

1.3.6.1.4.1.2636.3.1.13.1.6

INTEGER1 = unknown2 = running3 = ready4 = reset5 = runningAtFullSpeed6 = down7 = standby · Integer32

The operating state of this subject.

jnxPsePoePdDeviceMgrFault

1.3.6.1.4.1.2636.4.35.1

A jnxPsePoePdDeviceMgrFault trap signifies that the SNMP entity, acting in an agent role, has detected PD device manager fault.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxPsePoePdVoltInjFault

1.3.6.1.4.1.2636.4.35.2

A jnxPsePoePdVoltInjFault trap signifies that the SNMP entity, acting in an agent role, has detected PD voltage injection fault.

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxPsePoePdDeviceMgrOK

1.3.6.1.4.1.2636.4.36.1

A jnxPsePoePdDeviceMgrOK trap signifies that the SNMP entity, acting in an agent role, has recovered from the PD device manager fault state

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

jnxPsePoePdVoltInjOK

1.3.6.1.4.1.2636.4.36.2

A jnxPsePoePdVoltInjOK trap signifies that the SNMP entity, acting in an agent role, has recovered from the PD voltage injection fault

jnxContentsContainerIndex

1.3.6.1.4.1.2636.3.1.8.1.1

Integer32 (1..2147483647)

The associated jnxContainersIndex in the jnxContainersTable.

jnxContentsL1Index

1.3.6.1.4.1.2636.3.1.8.1.2

Integer32 (0..2147483647)

The level one index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL2Index

1.3.6.1.4.1.2636.3.1.8.1.3

Integer32 (0..2147483647)

The level two index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsL3Index

1.3.6.1.4.1.2636.3.1.8.1.4

Integer32 (0..2147483647)

The level three index of the container housing this subject. Zero if unavailable or inapplicable.

jnxContentsDescr

1.3.6.1.4.1.2636.3.1.8.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

The name or detailed description of this subject.

↑ To TOC