alarmIndex
Integer32 (1..65535)
An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.
2005-11-23
The MIB modules extends the Rmon as defined in RMON-MIB.
Download JUNIPER-RMON-MIB.txt Open JUNIPER-RMON-MIB.txt in a new tab
| Name | OID |
|---|---|
| jnxRmonAlarmTableaugments alarmTable (RMON-MIB) | 1.3.6.1.4.1.2636.3.13.1 |
| Name | OID |
|---|---|
| jnxRmonAlarmGetFailure | 1.3.6.1.4.1.2636.4.3.0.1 |
| jnxRmonGetOk | 1.3.6.1.4.1.2636.4.3.0.2 |
END OF TOC
1.3.6.1.4.1.2636.3.13.1
augments alarmTable (RMON-MIB)
Index: alarmIndex
Extensions to the rmon Alarm Table
from RMON-MIB
Integer32 (1..65535)
An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.
1.3.6.1.4.1.2636.3.13.1.1.1
Counter32
The number of times the internal get request for the variable monitored by this entry has failed.
1.3.6.1.4.1.2636.3.13.1.1.2
TimeTicks
The value of sysUpTime when an internal get request for the variable monitored by this entry last failed.
1.3.6.1.4.1.2636.3.13.1.1.3
INTEGER1 = other2 = noError3 = noSuchObject4 = outOfView5 = noSuchInstance6 = badReqId7 = oidMatchErr8 = oidBindErr9 = createPktErr10 = badObjType11 = processRestarted12 = lostInstance · Integer32
The reason why an internal get request for the variable monitored by this entry last failed.
1.3.6.1.4.1.2636.3.13.1.1.4
TimeTicks
The value of sysUpTime when an internal get request for the variable monitored by this entry succeeded and the entry left the getFailure state.
1.3.6.1.4.1.2636.3.13.1.1.5
INTEGER1 = unknown2 = underCreation3 = active4 = startup5 = risingThreshold6 = fallingThreshold7 = getFailure · Integer32
The current state of this rmon alarm entry. The states and their definitions are: underCreation ... entry has not been activated active ... entry is active & within thresholds startup ... entry still waiting for 1st value risingThreshold ... entry has crossed the rising threshold fallingThreshold... entry has crossed the falling threshold getFailure ... internal get request failed
1.3.6.1.4.1.2636.4.3.0.1
The SNMP trap that is generated when the get request for an alarm variable returns an error. The specific error is identified by jnxRmonAlarmGetFailReason.
1.3.6.1.2.1.16.3.1.1.1
Integer32 (1..65535)
An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.
1.3.6.1.2.1.16.3.1.1.3
OBJECT IDENTIFIER
The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an established alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1).
1.3.6.1.4.1.2636.3.13.1.1.3
INTEGER1 = other2 = noError3 = noSuchObject4 = outOfView5 = noSuchInstance6 = badReqId7 = oidMatchErr8 = oidBindErr9 = createPktErr10 = badObjType11 = processRestarted12 = lostInstance · Integer32
The reason why an internal get request for the variable monitored by this entry last failed.
1.3.6.1.4.1.2636.4.3.0.2
The SNMP trap that is generated when the get request for an alarm variable is successful. This is only sent after previous attempts were unsuccessful.
1.3.6.1.2.1.16.3.1.1.1
Integer32 (1..65535)
An index that uniquely identifies an entry in the alarm table. Each such entry defines a diagnostic sample at a particular interval for an object on the device.
1.3.6.1.2.1.16.3.1.1.3
OBJECT IDENTIFIER
The object identifier of the particular variable to be sampled. Only variables that resolve to an ASN.1 primitive type of INTEGER (INTEGER, Integer32, Counter32, Counter64, Gauge, or TimeTicks) may be sampled. Because SNMP access control is articulated entirely in terms of the contents of MIB views, no access control mechanism exists that can restrict the value of this object to identify only those objects that exist in a particular MIB view. Because there is thus no acceptable means of restricting the read access that could be obtained through the alarm mechanism, the probe must only grant write access to this object in those views that have read access to all objects on the probe. During a set operation, if the supplied variable name is not available in the selected MIB view, a badValue error must be returned. If at any time the variable name of an established alarmEntry is no longer available in the selected MIB view, the probe must change the status of this alarmEntry to invalid(4). This object may not be modified if the associated alarmStatus object is equal to valid(1).