paraNumber
1.3.6.1.2.1.10.34.1
Integer32
The number of ports (regardless of their current state) in the Parallel-printer-like port table.
1994-05-26
Download PARALLEL-MIB.txt Open PARALLEL-MIB.txt in a new tab
The MIB module for Parallel-printer-like hardware devices.
| Name | OID |
|---|---|
| paraNumber | 1.3.6.1.2.1.10.34.1 |
| Name | OID |
|---|---|
| paraPortTable | 1.3.6.1.2.1.10.34.2 |
| paraInSigTable | 1.3.6.1.2.1.10.34.3 |
| paraOutSigTable | 1.3.6.1.2.1.10.34.4 |
END OF TOC
1.3.6.1.2.1.10.34.1
Integer32
The number of ports (regardless of their current state) in the Parallel-printer-like port table.
1.3.6.1.2.1.10.34.2
Index: paraPortIndex
A list of port entries. The number of entries is given by the value of paraNumber.
1.3.6.1.2.1.10.34.2.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The value of ifIndex for the port. By convention and if possible, hardware port numbers map directly to external connectors. The value for each port must remain constant at least from one re-initialization of the network management agent to the next.
1.3.6.1.2.1.10.34.2.1.2
INTEGER1 = other2 = centronics3 = dataproducts · Integer32
The port's hardware type.
1.3.6.1.2.1.10.34.2.1.3
Integer32
The number of input signals for the port in the input signal table (paraPortInSigTable). The table contains entries only for those signals the software can detect and that are useful to observe.
1.3.6.1.2.1.10.34.2.1.4
Integer32
The number of output signals for the port in the output signal table (paraPortOutSigTable). The table contains entries only for those signals the software can assert and that are useful to observe.
1.3.6.1.2.1.10.34.3
Index: paraInSigPortIndex · paraInSigName
A list of port input control signal entries.
1.3.6.1.2.1.10.34.3.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The value of paraPortIndex for the port to which this entry belongs.
1.3.6.1.2.1.10.34.3.1.2
INTEGER1 = power2 = online3 = busy4 = paperout5 = fault · Integer32
Identification of a hardware signal.
1.3.6.1.2.1.10.34.3.1.3
INTEGER1 = none2 = on3 = off · Integer32
The current signal state.
1.3.6.1.2.1.10.34.3.1.4
Counter32
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.
1.3.6.1.2.1.10.34.4
Index: paraOutSigPortIndex · paraOutSigName
A list of port output control signal entries.
1.3.6.1.2.1.10.34.4.1.1
InterfaceIndexA unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must remain constant at least from one re-initialization of the entity's network management system to the next re-initialization. (1..2147483647) · Integer32 · hint d
The value of paraPortIndex for the port to which this entry belongs.
1.3.6.1.2.1.10.34.4.1.2
INTEGER1 = power2 = online3 = busy4 = paperout5 = fault · Integer32
Identification of a hardware signal.
1.3.6.1.2.1.10.34.4.1.3
INTEGER1 = none2 = on3 = off · Integer32
The current signal state.
1.3.6.1.2.1.10.34.4.1.4
Counter32
The number of times the signal has changed from 'on' to 'off' or from 'off' to 'on'.