EZ5 MIB Catalog

PTPBASE-MIB

2017-05-30

Download PTPBASE-MIB.txt Open PTPBASE-MIB.txt in a new tab

The MIB module for PTP version 2 Copyright (c) 2017 IETF Trust and the persons identified as authors of the code. All rights reserved. Redistribution and use in source and binary forms, with or without modification, is permitted pursuant to, and subject to the license terms contained in, the Simplified BSD License set forth in Section 4.c of the IETF Trust's Legal Provisions Relating to IETF Documents (http://trustee.ietf.org/license-info). Overview of PTP version 2 (IEEE Std. 1588-2008) [IEEE-1588-2008] defines a protocol enabling precise synchronization of clocks in measurement and control systems implemented with packet-based networks, the Precision Time Protocol version 2 (PTPv2). This MIB module does not address PTPv1, the earlier version defined in IEEE Std. 1588-2002. The protocol is applicable to network elements communicating using IP. The protocol enables heterogeneous systems that include clocks of various inherent precision, resolution, and stability to synchronize to a grandmaster clock. The protocol supports system-wide synchronization accuracy in the sub-microsecond range with minimal network and local clock computing resources. [IEEE-1588-2008] uses UDP/IP or Ethernet and can be adapted to other mappings. It includes formal mechanisms for message extensions, higher sampling rates, correction for asymmetry, a clock type to reduce error accumulation in large topologies, and specifications on how to incorporate the resulting additional data into the synchronization protocol. [IEEE-1588-2008] also defines conformance and management capability. MIB description This MIB module supports the Precision Time Protocol version 2 (PTPv2, hereafter designated as PTP) features of network element system devices, when using the default PTP profile described in [IEEE-1588-2008] when running over the IP network layer. It is envisioned that this MIB module will complement other managed objects to be defined to monitor and measure the performance of the PTP devices and telecom clocks supporting specific PTP profiles. Some other PTP profiles have their own MIB modules defined as part of the profile, and this MIB module is not intended to replace those MIB modules. Technical terms used in this module are defined in [IEEE-1588-2008]. The MIB module refers to sections of [IEEE-1588-2008]. Abbreviations: E2E End-to-End EUI Extended Unique Identifier GPS Global Positioning System IANA Internet Assigned Numbers Authority IP Internet Protocol NTP Network Time Protocol (see [RFC5905]) P2P Peer-to-Peer PTP Precision Time Protocol TAI International Atomic Time UDP User Datagram Protocol UTC Coordinated Universal Time References: [IEEE-1588-2008] IEEE Standard for A Precision Clock Synchronization Protocol for Networked Measurement and Control Systems, IEEE Std. 1588-2008, July 2008. The below table specifies the object formats of the various textual conventions used. Data type mapping Textual Convention SYNTAX ------------------- --------------------- ------------------ 5.3.2 TimeInterval PtpClockTimeInterval OCTET STRING(SIZE(1..255)) 5.3.3 Timestamp PtpClockTimestamp OCTET STRING(SIZE(6)) 5.3.4 ClockIdentity PtpClockIdentity OCTET STRING(SIZE(8)) 5.3.5 PortIdentity PtpClockPortNumber INTEGER(1..65535) 5.3.7 ClockQuality PtpClockQualityClassType

SCALARS (1) · TABLES (13)

Scalars (1)

NameOID
ptpbaseSystemProfile1.3.6.1.2.1.241.1.1.3

Tables (13)

NameOID
ptpbaseSystemTable1.3.6.1.2.1.241.1.1.1
ptpbaseSystemDomainTable1.3.6.1.2.1.241.1.1.2
ptpbaseClockCurrentDSTable1.3.6.1.2.1.241.1.2.1
ptpbaseClockParentDSTable1.3.6.1.2.1.241.1.2.2
ptpbaseClockDefaultDSTable1.3.6.1.2.1.241.1.2.3
ptpbaseClockRunningTable1.3.6.1.2.1.241.1.2.4
ptpbaseClockTimePropertiesDSTable1.3.6.1.2.1.241.1.2.5
ptpbaseClockTransDefaultDSTable1.3.6.1.2.1.241.1.2.6
ptpbaseClockPortTable1.3.6.1.2.1.241.1.2.7
ptpbaseClockPortDSTable1.3.6.1.2.1.241.1.2.8
ptpbaseClockPortRunningTable1.3.6.1.2.1.241.1.2.9
ptpbaseClockPortTransDSTable1.3.6.1.2.1.241.1.2.10
ptpbaseClockPortAssociateTable1.3.6.1.2.1.241.1.2.11

END OF TOC

Scalar details

ptpbaseSystemProfile

1.3.6.1.2.1.241.1.1.3

PtpClockProfileType1 = default2 = telecom3 = vendorspecificClock Profile used. A profile is the set of allowed PTP features applicable to a device.Reference: Sections 3.1.30 ('profile') and 19.3 ('PTP profiles') of [IEEE-1588-2008] · Integer32

This object specifies the PTP profile implemented on the system.

Table details

ptpbaseSystemTable

1.3.6.1.2.1.241.1.1.1

Index: ptpDomainIndex · ptpInstanceIndex

Table of count information about the PTP system for all domains.

ptpDomainIndex

1.3.6.1.2.1.241.1.1.1.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices. The Clock Domain is a logical group of clocks and devices that synchronize with each other using the PTP protocol. 0 Default domain 1 Alternate domain 1 2 Alternate domain 2 3 Alternate domain 3 4 - 127 User-defined domains 128 - 255 Reserved

ptpInstanceIndex

1.3.6.1.2.1.241.1.1.1.1.2

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this domain.

ptpDomainClockPortsTotal

1.3.6.1.2.1.241.1.1.1.1.3

Gauge32 · ptp ports

This object specifies the total number of clock ports configured within a domain in the system.

ptpbaseSystemDomainTable

1.3.6.1.2.1.241.1.1.2

Index: ptpbaseSystemDomainClockTypeIndex

Table of information about the PTP system for all clock modes -- ordinary, boundary, or transparent.

ptpbaseSystemDomainClockTypeIndex

1.3.6.1.2.1.241.1.1.2.1.1

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseSystemDomainTotals

1.3.6.1.2.1.241.1.1.2.1.2

Unsigned32 · domains

This object specifies the total number of PTP domains for this particular clock type configured in this node.

ptpbaseClockCurrentDSTable

1.3.6.1.2.1.241.1.2.1

Index: ptpbaseClockCurrentDSDomainIndex · ptpbaseClockCurrentDSClockTypeIndex · ptpbaseClockCurrentDSInstanceIndex

Table of information about the PTP clock currentDS for all domains.

ptpbaseClockCurrentDSDomainIndex

1.3.6.1.2.1.241.1.2.1.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockCurrentDSClockTypeIndex

1.3.6.1.2.1.241.1.2.1.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockCurrentDSInstanceIndex

1.3.6.1.2.1.241.1.2.1.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockCurrentDSStepsRemoved

1.3.6.1.2.1.241.1.2.1.1.4

Unsigned32 · Steps

The current clock dataset stepsRemoved value. This object specifies the distance measured by the number of boundary clocks between the local clock and the foreign master as indicated in the stepsRemoved field of Announce messages.

ptpbaseClockCurrentDSOffsetFromMaster

1.3.6.1.2.1.241.1.2.1.1.5

PtpClockTimeIntervalThis textual convention corresponds to the TimeInterval structure indicated in Section 5.3.2 of [IEEE-1588-2008]. It will be presented in the form of a character array. Network byte order is assumed.Reference: Sections 5.3.2 ('TimeInterval') and 7.7.2.1 ('Timer interval specification') of [IEEE-1588-2008] SIZE (1..255) · OCTET STRING · hint 255a · Time Interval

This object specifies the current clock dataset ClockOffset value. The value of the computation of the offset in time between a slave and a master clock.

ptpbaseClockCurrentDSMeanPathDelay

1.3.6.1.2.1.241.1.2.1.1.6

PtpClockTimeIntervalThis textual convention corresponds to the TimeInterval structure indicated in Section 5.3.2 of [IEEE-1588-2008]. It will be presented in the form of a character array. Network byte order is assumed.Reference: Sections 5.3.2 ('TimeInterval') and 7.7.2.1 ('Timer interval specification') of [IEEE-1588-2008] SIZE (1..255) · OCTET STRING · hint 255a · Time Interval

This object specifies the current clock dataset MeanPathDelay value. The mean path delay between a pair of ports as measured by the delay request-response mechanism.

ptpbaseClockParentDSTable

1.3.6.1.2.1.241.1.2.2

Index: ptpbaseClockParentDSDomainIndex · ptpbaseClockParentDSClockTypeIndex · ptpbaseClockParentDSInstanceIndex

Table of information about the PTP clock parentDS for all domains.

ptpbaseClockParentDSDomainIndex

1.3.6.1.2.1.241.1.2.2.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockParentDSClockTypeIndex

1.3.6.1.2.1.241.1.2.2.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockParentDSInstanceIndex

1.3.6.1.2.1.241.1.2.2.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockParentDSParentPortIdentity

1.3.6.1.2.1.241.1.2.2.1.4

OCTET STRING SIZE (1..256)

This object specifies the value of portIdentity of the port on the master that issues the Sync messages used in synchronizing this clock.

ptpbaseClockParentDSParentStats

1.3.6.1.2.1.241.1.2.2.1.5

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the parentDS ParentStats value. This value indicates whether the values of ParentDSOffset and ParentDSClockPhChRate have been measured and are valid. A TRUE value shall indicate valid data.

ptpbaseClockParentDSOffset

1.3.6.1.2.1.241.1.2.2.1.6

PtpClockIntervalBase2The interval included in message types Announce, Sync, Delay_Req, and Pdelay_Req as indicated in Section 7.7.2.1 of [IEEE-1588-2008].Reference: Section 7.7.2.1 ('General interval specification') of [IEEE-1588-2008] (-128..127) · Integer32 · hint d

This object specifies the parentDS ParentOffsetScaledLogVariance value. This value is the variance of the parent clock's phase as measured by the local clock.

ptpbaseClockParentDSClockPhChRate

1.3.6.1.2.1.241.1.2.2.1.7

Integer32

This object specifies the clock's parentDS ParentClockPhaseChangeRate value. This value is an estimate of the parent clock's phase change rate as measured by the slave clock.

ptpbaseClockParentDSGMClockIdentity

1.3.6.1.2.1.241.1.2.2.1.8

PtpClockIdentityThe clock identity is an 8-octet array and will be presented in the form of a character array. Network byte order is assumed. The value of the PtpClockIdentity should be taken from the IEEE EUI-64 individual assigned numbers as indicated in Section 7.5.2.2.2 of [IEEE-1588-2008]. It can also be a non-EUI-64 address as defined in Section 7.5.2.2.3 of [IEEE-1588-2008]. The clock identifier can be constructed from existing EUI-48 assignments.Reference: Section 7.5.2.2.1 ('General') of [IEEE-1588-2008] SIZE (8) · OCTET STRING · hint 255a

This object specifies the parentDS grandmaster clock identity.

ptpbaseClockParentDSGMClockPriority1

1.3.6.1.2.1.241.1.2.2.1.9

Unsigned32

This object specifies the parentDS grandmaster clock priority1.

ptpbaseClockParentDSGMClockPriority2

1.3.6.1.2.1.241.1.2.2.1.10

Unsigned32

This object specifies the parentDS grandmaster clock priority2.

ptpbaseClockParentDSGMClockQualityClass

1.3.6.1.2.1.241.1.2.2.1.11

PtpClockQualityClassType6 = clockclass67 = clockclass713 = clockclass1314 = clockclass1452 = clockclass5258 = clockclass58The ClockQuality as specified in Section 5.3.7, Section 7.6.2.4, and Table 5 of [IEEE-1588-2008].Reference: Section 5.3.7 ('ClockQuality'), Section 7.6.2.4 ('clockClass'), and Table 5 ('clockClass specifications') of [IEEE-1588-2008]. · Integer32

This object specifies the parentDS grandmaster clock quality class.

ptpbaseClockParentDSGMClockQualityAccuracy

1.3.6.1.2.1.241.1.2.2.1.12

PtpClockQualityAccuracyType32 = nanoSecond2533 = nanoSecond10034 = nanoSecond25035 = microSec136 = microSec2dot537 = microSec1038 = microSec2539 = microSec10040 = microSec25041 = milliSec142 = milliSec2dot543 = milliSec1044 = milliSec2545 = milliSec10046 = milliSec25047 = second148 = second1049 = secondGreater10254 = unknownThe ClockQuality as specified in Section 5.3.7, Section 7.6.2.5, and Table 6 of [IEEE-1588-2008]. The following values are not represented in the enumerated values. 0x01-0x1F Reserved 0x32-0x7F Reserved It is important to note that Section 7.1.1 of RFC 2578 allows for gaps and for enumerated values to start at zero when indicated by the protocol.Reference: Section 5.3.7 ('ClockQuality'), Section 7.6.2.5 ('clockAccuracy'), and Table 6 ('clockAccuracy enumeration') of [IEEE-1588-2008] · Integer32

This object specifies the parentDS grandmaster clock quality accuracy.

ptpbaseClockParentDSGMClockQualityOffset

1.3.6.1.2.1.241.1.2.2.1.13

Unsigned32

This object specifies the parentDS grandmaster clock quality offset.

ptpbaseClockDefaultDSTable

1.3.6.1.2.1.241.1.2.3

Index: ptpbaseClockDefaultDSDomainIndex · ptpbaseClockDefaultDSClockTypeIndex · ptpbaseClockDefaultDSInstanceIndex

Table of information about the PTP clock defaultDS for all domains.

ptpbaseClockDefaultDSDomainIndex

1.3.6.1.2.1.241.1.2.3.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockDefaultDSClockTypeIndex

1.3.6.1.2.1.241.1.2.3.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockDefaultDSInstanceIndex

1.3.6.1.2.1.241.1.2.3.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockDefaultDSTwoStepFlag

1.3.6.1.2.1.241.1.2.3.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies whether the two-step process is used.

ptpbaseClockDefaultDSClockIdentity

1.3.6.1.2.1.241.1.2.3.1.5

PtpClockIdentityThe clock identity is an 8-octet array and will be presented in the form of a character array. Network byte order is assumed. The value of the PtpClockIdentity should be taken from the IEEE EUI-64 individual assigned numbers as indicated in Section 7.5.2.2.2 of [IEEE-1588-2008]. It can also be a non-EUI-64 address as defined in Section 7.5.2.2.3 of [IEEE-1588-2008]. The clock identifier can be constructed from existing EUI-48 assignments.Reference: Section 7.5.2.2.1 ('General') of [IEEE-1588-2008] SIZE (8) · OCTET STRING · hint 255a

This object specifies the defaultDS clockIdentity member.

ptpbaseClockDefaultDSPriority1

1.3.6.1.2.1.241.1.2.3.1.6

Unsigned32

This object specifies the defaultDS priority1 member.

ptpbaseClockDefaultDSPriority2

1.3.6.1.2.1.241.1.2.3.1.7

Unsigned32

This object specifies the defaultDS priority2 member.

ptpbaseClockDefaultDSSlaveOnly

1.3.6.1.2.1.241.1.2.3.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies whether the SlaveOnly flag is set.

ptpbaseClockDefaultDSQualityClass

1.3.6.1.2.1.241.1.2.3.1.9

PtpClockQualityClassType6 = clockclass67 = clockclass713 = clockclass1314 = clockclass1452 = clockclass5258 = clockclass58The ClockQuality as specified in Section 5.3.7, Section 7.6.2.4, and Table 5 of [IEEE-1588-2008].Reference: Section 5.3.7 ('ClockQuality'), Section 7.6.2.4 ('clockClass'), and Table 5 ('clockClass specifications') of [IEEE-1588-2008]. · Integer32

This object specifies the defaultDS Quality Class.

ptpbaseClockDefaultDSQualityAccuracy

1.3.6.1.2.1.241.1.2.3.1.10

PtpClockQualityAccuracyType32 = nanoSecond2533 = nanoSecond10034 = nanoSecond25035 = microSec136 = microSec2dot537 = microSec1038 = microSec2539 = microSec10040 = microSec25041 = milliSec142 = milliSec2dot543 = milliSec1044 = milliSec2545 = milliSec10046 = milliSec25047 = second148 = second1049 = secondGreater10254 = unknownThe ClockQuality as specified in Section 5.3.7, Section 7.6.2.5, and Table 6 of [IEEE-1588-2008]. The following values are not represented in the enumerated values. 0x01-0x1F Reserved 0x32-0x7F Reserved It is important to note that Section 7.1.1 of RFC 2578 allows for gaps and for enumerated values to start at zero when indicated by the protocol.Reference: Section 5.3.7 ('ClockQuality'), Section 7.6.2.5 ('clockAccuracy'), and Table 6 ('clockAccuracy enumeration') of [IEEE-1588-2008] · Integer32

This object specifies the defaultDS Quality Accuracy.

ptpbaseClockDefaultDSQualityOffset

1.3.6.1.2.1.241.1.2.3.1.11

Integer32

This object specifies the defaultDS Quality offset.

ptpbaseClockRunningTable

1.3.6.1.2.1.241.1.2.4

Index: ptpbaseClockRunningDomainIndex · ptpbaseClockRunningClockTypeIndex · ptpbaseClockRunningInstanceIndex

Table of information about the PTP clock running datasets for all domains.

ptpbaseClockRunningDomainIndex

1.3.6.1.2.1.241.1.2.4.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockRunningClockTypeIndex

1.3.6.1.2.1.241.1.2.4.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockRunningInstanceIndex

1.3.6.1.2.1.241.1.2.4.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockRunningState

1.3.6.1.2.1.241.1.2.4.1.4

PtpClockStateType1 = freerun2 = holdover3 = acquiring4 = frequencyLocked5 = phaseAlignedThe clock state returned by a PTP engine. Clock State Value ------------------------ Freerun state 1 Holdover state 2 Acquiring state 3 Freq_locked state 4 Phase_aligned state 5 · Integer32

This object specifies the clock state returned by a PTP engine.

ptpbaseClockRunningPacketsSent

1.3.6.1.2.1.241.1.2.4.1.5

Counter64 (0..18446744073709551615)

This object specifies the total number of all unicast and multicast packets that have been sent out for this clock in this domain for this type. These counters are discontinuous.

ptpbaseClockRunningPacketsReceived

1.3.6.1.2.1.241.1.2.4.1.6

Counter64 (0..18446744073709551615)

This object specifies the total number of all unicast and multicast packets that have been received for this clock in this domain for this type. These counters are discontinuous.

ptpbaseClockTimePropertiesDSTable

1.3.6.1.2.1.241.1.2.5

Index: ptpbaseClockTimePropertiesDSDomainIndex · ptpbaseClockTimePropertiesDSClockTypeIndex · ptpbaseClockTimePropertiesDSInstanceIndex

Table of information about the PTP clock timePropertiesDS for all domains.

ptpbaseClockTimePropertiesDSDomainIndex

1.3.6.1.2.1.241.1.2.5.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockTimePropertiesDSClockTypeIndex

1.3.6.1.2.1.241.1.2.5.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockTimePropertiesDSInstanceIndex

1.3.6.1.2.1.241.1.2.5.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockTimePropertiesDSCurrentUTCOffsetValid

1.3.6.1.2.1.241.1.2.5.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the timePropertiesDS value of whether the current UTC offset is valid.

ptpbaseClockTimePropertiesDSCurrentUTCOffset

1.3.6.1.2.1.241.1.2.5.1.5

Integer32

This object specifies the timePropertiesDS value of the current UTC offset. In PTP systems whose epoch is the PTP epoch, the value of timePropertiesDS.currentUtcOffset is the offset between TAI and UTC; otherwise, the value has no meaning. The value shall be in units of seconds.

ptpbaseClockTimePropertiesDSLeap59

1.3.6.1.2.1.241.1.2.5.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the Leap59 value in the clock currentDS.

ptpbaseClockTimePropertiesDSLeap61

1.3.6.1.2.1.241.1.2.5.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the Leap61 value in the clock currentDS.

ptpbaseClockTimePropertiesDSTimeTraceable

1.3.6.1.2.1.241.1.2.5.1.8

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the Time Traceable value in the clock currentDS.

ptpbaseClockTimePropertiesDSFreqTraceable

1.3.6.1.2.1.241.1.2.5.1.9

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the Frequency Traceable value in the clock currentDS.

ptpbaseClockTimePropertiesDSPTPTimescale

1.3.6.1.2.1.241.1.2.5.1.10

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the PTP Timescale value in the clock currentDS.

ptpbaseClockTimePropertiesDSSource

1.3.6.1.2.1.241.1.2.5.1.11

PtpClockTimeSourceType16 = atomicClock32 = gps48 = terrestrialRadio64 = ptp80 = ntp96 = handSet144 = other160 = internalOscillatorThe ClockQuality as specified in Sections 5.3.7, Section 7.6.2.6, and Table 7 of [IEEE-1588-2008]. The following values are not represented in the enumerated values. 0xF0-0xFE For use by alternate PTP profiles 0xFF Reserved It is important to note that Section 7.1.1 of RFC 2578 allows for gaps and for enumerated values to start at zero when indicated by the protocol.Reference: Section 5.3.7 ('ClockQuality'), Section 7.6.2.6 ('timeSource'), and Table 7 ('timeSource enumeration') of [IEEE-1588-2008]. · Integer32

This object specifies the Timesource value in the clock currentDS.

ptpbaseClockTransDefaultDSTable

1.3.6.1.2.1.241.1.2.6

Index: ptpbaseClockTransDefaultDSDomainIndex · ptpbaseClockTransDefaultDSInstanceIndex

Table of information about the PTP transparentClockDefaultDS for all domains.

ptpbaseClockTransDefaultDSDomainIndex

1.3.6.1.2.1.241.1.2.6.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockTransDefaultDSInstanceIndex

1.3.6.1.2.1.241.1.2.6.1.2

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockTransDefaultDSClockIdentity

1.3.6.1.2.1.241.1.2.6.1.3

PtpClockIdentityThe clock identity is an 8-octet array and will be presented in the form of a character array. Network byte order is assumed. The value of the PtpClockIdentity should be taken from the IEEE EUI-64 individual assigned numbers as indicated in Section 7.5.2.2.2 of [IEEE-1588-2008]. It can also be a non-EUI-64 address as defined in Section 7.5.2.2.3 of [IEEE-1588-2008]. The clock identifier can be constructed from existing EUI-48 assignments.Reference: Section 7.5.2.2.1 ('General') of [IEEE-1588-2008] SIZE (8) · OCTET STRING · hint 255a

This object specifies the value of the clockIdentity attribute of the local clock.

ptpbaseClockTransDefaultDSNumOfPorts

1.3.6.1.2.1.241.1.2.6.1.4

Counter32

This object specifies the number of PTP ports of the device. These counters are discontinuous.

ptpbaseClockTransDefaultDSDelay

1.3.6.1.2.1.241.1.2.6.1.5

PtpClockMechanismType1 = e2e2 = p2p254 = disabledThe clock type based on whether end-to-end or peer-to-peer mechanisms are used. The mechanism used to calculate the Mean Path Delay as indicated in Table 9 of [IEEE-1588-2008].Reference: Sections 8.2.5.4.4 ('portDS.delayMechanism'), 6.6.4 ('Measuring link propagation delay in clocks supporting peer-to-peer path correction'), and 7.4.2 ('communication Path asymmetry') of [IEEE-1588-2008]. · Integer32

This object, if the transparent clock is an end-to-end transparent clock, has the value of e2e; if the transparent clock is a peer-to-peer transparent clock, the value is p2p.

ptpbaseClockTransDefaultDSPrimaryDomain

1.3.6.1.2.1.241.1.2.6.1.6

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the value of the primary syntonization domain. The initialization value is 0.

ptpbaseClockPortTable

1.3.6.1.2.1.241.1.2.7

Index: ptpbaseClockPortDomainIndex · ptpbaseClockPortClockTypeIndex · ptpbaseClockPortClockInstanceIndex · ptpbaseClockPortTablePortNumberIndex

Table of information about the clock ports for a particular domain.

ptpbaseClockPortDomainIndex

1.3.6.1.2.1.241.1.2.7.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockPortClockTypeIndex

1.3.6.1.2.1.241.1.2.7.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockPortClockInstanceIndex

1.3.6.1.2.1.241.1.2.7.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockPortTablePortNumberIndex

1.3.6.1.2.1.241.1.2.7.1.4

PtpClockPortNumberAn index identifying a specific PTP port on a PTP node.Reference: Sections 7.5.2.3 ('portNumber') and 5.3.5 ('PortIdentity') of [IEEE-1588-2008] (0..65535) · Unsigned32 · hint d

This object specifies the PTP portNumber for this port.

ptpbaseClockPortName

1.3.6.1.2.1.241.1.2.7.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (1..64) · OCTET STRING · hint 255a

This object specifies the PTP clock port name configured on the node.

ptpbaseClockPortRole

1.3.6.1.2.1.241.1.2.7.1.6

PtpClockRoleType1 = master2 = slaveThe Clock Role. The protocol generates a master-slave relationship among the clocks in the system. Clock Role Value ------------------------- Master clock 1 Slave clock 2 · Integer32

This object describes the current role (slave/master) of the port.

ptpbaseClockPortSyncTwoStep

1.3.6.1.2.1.241.1.2.7.1.7

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies that two-step clock operation between the PTP master and slave device is enabled.

ptpbaseClockPortCurrentPeerAddressType

1.3.6.1.2.1.241.1.2.7.1.8

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

This object specifies the current peer's network address type used for PTP communication.

ptpbaseClockPortCurrentPeerAddress

1.3.6.1.2.1.241.1.2.7.1.9

PtpClockPortTransportTypeAddressThe clock port transport protocol address used for this communication between the clock nodes. This is a string corresponding to the address type as specified by the transport type used. The transport types can be defined elsewhere, in addition to the ones defined in this document. This can be an address of type IP version 4, IP version 6, Ethernet, DeviceNET, ControlNET, or IEC61158. The OCTET STRING representation of the OID of ptpbaseWellKnownTransportTypes will be used in the values contained in the OCTET STRING.Reference: Annex D (IPv4), Annex E (IPv6), Annex F (Ethernet), Annex G (DeviceNET), Annex H (ControlNET), and Annex I (IEC61158) of [IEEE-1588-2008] SIZE (1..255) · OCTET STRING · hint 255a

This object specifies the current peer's network address used for PTP communication.

ptpbaseClockPortNumOfAssociatedPorts

1.3.6.1.2.1.241.1.2.7.1.10

Gauge32

This object specifies the following: For a master port - the number of PTP slave sessions (peers) associated with this PTP port. For a slave port - the number of masters available to this slave port (might or might not be peered).

ptpbaseClockPortDSTable

1.3.6.1.2.1.241.1.2.8

Index: ptpbaseClockPortDSDomainIndex · ptpbaseClockPortDSClockTypeIndex · ptpbaseClockPortDSClockInstanceIndex · ptpbaseClockPortDSPortNumberIndex

Table of information about the clock's portDS for a particular domain.

ptpbaseClockPortDSDomainIndex

1.3.6.1.2.1.241.1.2.8.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockPortDSClockTypeIndex

1.3.6.1.2.1.241.1.2.8.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockPortDSClockInstanceIndex

1.3.6.1.2.1.241.1.2.8.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockPortDSPortNumberIndex

1.3.6.1.2.1.241.1.2.8.1.4

PtpClockPortNumberAn index identifying a specific PTP port on a PTP node.Reference: Sections 7.5.2.3 ('portNumber') and 5.3.5 ('PortIdentity') of [IEEE-1588-2008] (0..65535) · Unsigned32 · hint d

This object specifies the PTP portNumber associated with this PTP port.

ptpbaseClockPortDSName

1.3.6.1.2.1.241.1.2.8.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (1..64) · OCTET STRING · hint 255a

This object specifies the PTP clock portDS name.

ptpbaseClockPortDSPortIdentity

1.3.6.1.2.1.241.1.2.8.1.6

OCTET STRING SIZE (1..256)

This object specifies the PTP clock port Identity.

ptpbaseClockPortDSlogAnnouncementInterval

1.3.6.1.2.1.241.1.2.8.1.7

PtpClockIntervalBase2The interval included in message types Announce, Sync, Delay_Req, and Pdelay_Req as indicated in Section 7.7.2.1 of [IEEE-1588-2008].Reference: Section 7.7.2.1 ('General interval specification') of [IEEE-1588-2008] (-128..127) · Integer32 · hint d · Time Interval

This object specifies the Announce message transmission interval associated with this clock port.

ptpbaseClockPortDSAnnounceRctTimeout

1.3.6.1.2.1.241.1.2.8.1.8

Integer32

This object specifies the Announce receipt timeout associated with this clock port.

ptpbaseClockPortDSlogSyncInterval

1.3.6.1.2.1.241.1.2.8.1.9

PtpClockIntervalBase2The interval included in message types Announce, Sync, Delay_Req, and Pdelay_Req as indicated in Section 7.7.2.1 of [IEEE-1588-2008].Reference: Section 7.7.2.1 ('General interval specification') of [IEEE-1588-2008] (-128..127) · Integer32 · hint d · Time Interval

This object specifies the Sync message transmission interval.

ptpbaseClockPortDSMinDelayReqInterval

1.3.6.1.2.1.241.1.2.8.1.10

Integer32

This object specifies the Delay_Req message transmission interval.

ptpbaseClockPortDSPeerDelayReqInterval

1.3.6.1.2.1.241.1.2.8.1.11

Integer32

This object specifies the Pdelay_Req message transmission interval.

ptpbaseClockPortDSDelayMech

1.3.6.1.2.1.241.1.2.8.1.12

PtpClockMechanismType1 = e2e2 = p2p254 = disabledThe clock type based on whether end-to-end or peer-to-peer mechanisms are used. The mechanism used to calculate the Mean Path Delay as indicated in Table 9 of [IEEE-1588-2008].Reference: Sections 8.2.5.4.4 ('portDS.delayMechanism'), 6.6.4 ('Measuring link propagation delay in clocks supporting peer-to-peer path correction'), and 7.4.2 ('communication Path asymmetry') of [IEEE-1588-2008]. · Integer32

This object specifies the delay mechanism used. If the clock is an end-to-end clock, the value is e2e; if the clock is a peer to-peer clock, the value is p2p.

ptpbaseClockPortDSPeerMeanPathDelay

1.3.6.1.2.1.241.1.2.8.1.13

PtpClockTimeIntervalThis textual convention corresponds to the TimeInterval structure indicated in Section 5.3.2 of [IEEE-1588-2008]. It will be presented in the form of a character array. Network byte order is assumed.Reference: Sections 5.3.2 ('TimeInterval') and 7.7.2.1 ('Timer interval specification') of [IEEE-1588-2008] SIZE (1..255) · OCTET STRING · hint 255a · Time Interval

This object specifies the peer meanPathDelay.

ptpbaseClockPortDSGrantDuration

1.3.6.1.2.1.241.1.2.8.1.14

Unsigned32 · seconds

This object specifies the grant duration allocated by the master.

ptpbaseClockPortDSPTPVersion

1.3.6.1.2.1.241.1.2.8.1.15

Unsigned32

This object specifies the PTP version being used.

ptpbaseClockPortRunningTable

1.3.6.1.2.1.241.1.2.9

Index: ptpbaseClockPortRunningDomainIndex · ptpbaseClockPortRunningClockTypeIndex · ptpbaseClockPortRunningClockInstanceIndex · ptpbaseClockPortRunningPortNumberIndex

Table of information about the clock ports running datasets for a particular domain.

ptpbaseClockPortRunningDomainIndex

1.3.6.1.2.1.241.1.2.9.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockPortRunningClockTypeIndex

1.3.6.1.2.1.241.1.2.9.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the clock type as defined in the textual convention description.

ptpbaseClockPortRunningClockInstanceIndex

1.3.6.1.2.1.241.1.2.9.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockPortRunningPortNumberIndex

1.3.6.1.2.1.241.1.2.9.1.4

PtpClockPortNumberAn index identifying a specific PTP port on a PTP node.Reference: Sections 7.5.2.3 ('portNumber') and 5.3.5 ('PortIdentity') of [IEEE-1588-2008] (0..65535) · Unsigned32 · hint d

This object specifies the PTP portNumber associated with this clock port.

ptpbaseClockPortRunningName

1.3.6.1.2.1.241.1.2.9.1.5

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (1..64) · OCTET STRING · hint 255a

This object specifies the PTP clock port name.

ptpbaseClockPortRunningState

1.3.6.1.2.1.241.1.2.9.1.6

PtpClockPortState1 = initializing2 = faulty3 = disabled4 = listening5 = preMaster6 = master7 = passive8 = uncalibrated9 = slaveThis is the value of the current state of the protocol engine associated with this port.Reference: Sections 8.2.5.3.1 ('portState') and 9.2.5 ('State machines') of [IEEE-1588-2008] · Integer32

This object specifies the port state returned by PTP engine: initializing faulty disabled listening preMaster master passive uncalibrated slave

ptpbaseClockPortRunningRole

1.3.6.1.2.1.241.1.2.9.1.7

PtpClockRoleType1 = master2 = slaveThe Clock Role. The protocol generates a master-slave relationship among the clocks in the system. Clock Role Value ------------------------- Master clock 1 Slave clock 2 · Integer32

This object specifies the Clock Role.

ptpbaseClockPortRunningInterfaceIndex

1.3.6.1.2.1.241.1.2.9.1.8

InterfaceIndexOrZeroThis textual convention is an extension of the InterfaceIndex convention. The latter defines a greater than zero value used to identify an interface or interface sub-layer in the managed system. This extension permits the additional value of zero. the value zero is object-specific and must therefore be defined as part of the description of any object which uses this syntax. Examples of the usage of zero might include situations where interface was unknown, or when none or all interfaces need to be referenced. (0..2147483647) · Integer32 · hint d

This object specifies the interface on the node being used by the PTP clock for PTP communication.

ptpbaseClockPortRunningTransport

1.3.6.1.2.1.241.1.2.9.1.9

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

This object specifies the transport protocol being used for PTP communication (the mapping used).

ptpbaseClockPortRunningEncapsulationType

1.3.6.1.2.1.241.1.2.9.1.10

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

This object specifies the type of encapsulation if the interface is adding extra layers (e.g., VLAN or Pseudowire encapsulation) for the PTP messages.

ptpbaseClockPortRunningTxMode

1.3.6.1.2.1.241.1.2.9.1.11

PtpClockTxModeType1 = unicast2 = multicast3 = multicastmixTransmission mode. Unicast: Using unicast communication channel. Multicast: Using Multicast communication channel. multicast-mix: Using multicast-unicast communication channel · Integer32

This object specifies the clock transmission mode as: unicast: Using unicast communication channel multicast: Using multicast communication channel multicast-mix: Using multicast-unicast communication channel

ptpbaseClockPortRunningRxMode

1.3.6.1.2.1.241.1.2.9.1.12

PtpClockTxModeType1 = unicast2 = multicast3 = multicastmixTransmission mode. Unicast: Using unicast communication channel. Multicast: Using Multicast communication channel. multicast-mix: Using multicast-unicast communication channel · Integer32

This object specifies the clock receive mode as: unicast: Using unicast communication channel multicast: Using multicast communication channel multicast-mix: Using multicast-unicast communication channel

ptpbaseClockPortRunningPacketsReceived

1.3.6.1.2.1.241.1.2.9.1.13

Counter64 (0..18446744073709551615) · packets

This object specifies the packets received on the clock port (cumulative). These counters are discontinuous.

ptpbaseClockPortRunningPacketsSent

1.3.6.1.2.1.241.1.2.9.1.14

Counter64 (0..18446744073709551615) · packets

This object specifies the packets sent on the clock port (cumulative). These counters are discontinuous.

ptpbaseClockPortTransDSTable

1.3.6.1.2.1.241.1.2.10

Index: ptpbaseClockPortTransDSDomainIndex · ptpbaseClockPortTransDSInstanceIndex · ptpbaseClockPortTransDSPortNumberIndex

Table of information about the transparentClockPortDS for a particular domain.

ptpbaseClockPortTransDSDomainIndex

1.3.6.1.2.1.241.1.2.10.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the domain number used to create a logical group of PTP devices.

ptpbaseClockPortTransDSInstanceIndex

1.3.6.1.2.1.241.1.2.10.1.2

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpbaseClockPortTransDSPortNumberIndex

1.3.6.1.2.1.241.1.2.10.1.3

PtpClockPortNumberAn index identifying a specific PTP port on a PTP node.Reference: Sections 7.5.2.3 ('portNumber') and 5.3.5 ('PortIdentity') of [IEEE-1588-2008] (0..65535) · Unsigned32 · hint d

This object specifies the PTP portNumber associated with this port.

ptpbaseClockPortTransDSPortIdentity

1.3.6.1.2.1.241.1.2.10.1.4

PtpClockIdentityThe clock identity is an 8-octet array and will be presented in the form of a character array. Network byte order is assumed. The value of the PtpClockIdentity should be taken from the IEEE EUI-64 individual assigned numbers as indicated in Section 7.5.2.2.2 of [IEEE-1588-2008]. It can also be a non-EUI-64 address as defined in Section 7.5.2.2.3 of [IEEE-1588-2008]. The clock identifier can be constructed from existing EUI-48 assignments.Reference: Section 7.5.2.2.1 ('General') of [IEEE-1588-2008] SIZE (8) · OCTET STRING · hint 255a

This object specifies the value of the PortIdentity attribute of the local port.

ptpbaseClockPortTransDSlogMinPdelayReqInt

1.3.6.1.2.1.241.1.2.10.1.5

PtpClockIntervalBase2The interval included in message types Announce, Sync, Delay_Req, and Pdelay_Req as indicated in Section 7.7.2.1 of [IEEE-1588-2008].Reference: Section 7.7.2.1 ('General interval specification') of [IEEE-1588-2008] (-128..127) · Integer32 · hint d

This object specifies the value of the logarithm to the base 2 of the minPdelayReqInterval.

ptpbaseClockPortTransDSFaultyFlag

1.3.6.1.2.1.241.1.2.10.1.6

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object specifies the value TRUE if the port is faulty and FALSE if the port is operating normally.

ptpbaseClockPortTransDSPeerMeanPathDelay

1.3.6.1.2.1.241.1.2.10.1.7

PtpClockTimeIntervalThis textual convention corresponds to the TimeInterval structure indicated in Section 5.3.2 of [IEEE-1588-2008]. It will be presented in the form of a character array. Network byte order is assumed.Reference: Sections 5.3.2 ('TimeInterval') and 7.7.2.1 ('Timer interval specification') of [IEEE-1588-2008] SIZE (1..255) · OCTET STRING · hint 255a · Time Interval

This object specifies, if the delayMechanism used is p2p, the value of the estimate of the current one-way propagation delay, i.e., <meanPathDelay> on the link attached to this port, computed using the peer delay mechanism. If the value of the delayMechanism used is e2e, then the value will be zero.

ptpbaseClockPortAssociateTable

1.3.6.1.2.1.241.1.2.11

Index: ptpClockPortCurrentDomainIndex · ptpClockPortCurrentClockTypeIndex · ptpClockPortCurrentClockInstanceIndex · ptpClockPortCurrentPortNumberIndex · ptpbaseClockPortAssociatePortIndex

Table of information about a given port's associated ports. For a master port: multiple slave ports that have established sessions with the current master port. For a slave port: the list of masters available for a given slave port. Session information (packets, errors) to be displayed based on availability and scenario.

ptpClockPortCurrentDomainIndex

1.3.6.1.2.1.241.1.2.11.1.1

PtpClockDomainTypeThe Domain is identified by an integer, the domainNumber, in the range of 0 to 255. An integer value that is used to assign each PTP device to a particular domain.Reference: Section 7.1 ('Domains') and Table 2 ('domainNumber') of [IEEE-1588-2008] (0..255) · Unsigned32 · hint d

This object specifies the given port's domain number.

ptpClockPortCurrentClockTypeIndex

1.3.6.1.2.1.241.1.2.11.1.2

PtpClockType1 = ordinaryClock2 = boundaryClock3 = transparentClock4 = boundaryNodeThe clock types as defined in the MIB module description.Reference: Section 6.5.1 ('PTP device types') of [IEEE-1588-2008]. · Integer32

This object specifies the given port's clock type.

ptpClockPortCurrentClockInstanceIndex

1.3.6.1.2.1.241.1.2.11.1.3

PtpClockInstanceTypeThe instance of the clock of a given clock type in a given domain. (0..255) · Unsigned32 · hint d

This object specifies the instance of the clock for this clock type in the given domain.

ptpClockPortCurrentPortNumberIndex

1.3.6.1.2.1.241.1.2.11.1.4

PtpClockPortNumberAn index identifying a specific PTP port on a PTP node.Reference: Sections 7.5.2.3 ('portNumber') and 5.3.5 ('PortIdentity') of [IEEE-1588-2008] (0..65535) · Unsigned32 · hint d

This object specifies the PTP portNumber for the given port.

ptpbaseClockPortAssociatePortIndex

1.3.6.1.2.1.241.1.2.11.1.5

Unsigned32 (1..65535)

This object specifies the associated port's serial number in the current port's context.

ptpbaseClockPortAssociateAddressType

1.3.6.1.2.1.241.1.2.11.1.6

AutonomousTypeRepresents an independently extensible type identification value. It may, for example, indicate a particular sub-tree with further MIB definitions, or define a particular type of protocol or hardware. · OBJECT IDENTIFIER

This object specifies the peer port's network address type used for PTP communication. The OCTET STRING representation of the OID of ptpbaseWellKnownTransportTypes will be used in the values contained in the OCTET STRING.

ptpbaseClockPortAssociateAddress

1.3.6.1.2.1.241.1.2.11.1.7

PtpClockPortTransportTypeAddressThe clock port transport protocol address used for this communication between the clock nodes. This is a string corresponding to the address type as specified by the transport type used. The transport types can be defined elsewhere, in addition to the ones defined in this document. This can be an address of type IP version 4, IP version 6, Ethernet, DeviceNET, ControlNET, or IEC61158. The OCTET STRING representation of the OID of ptpbaseWellKnownTransportTypes will be used in the values contained in the OCTET STRING.Reference: Annex D (IPv4), Annex E (IPv6), Annex F (Ethernet), Annex G (DeviceNET), Annex H (ControlNET), and Annex I (IEC61158) of [IEEE-1588-2008] SIZE (1..255) · OCTET STRING · hint 255a

This object specifies the peer port's network address used for PTP communication.

ptpbaseClockPortAssociatePacketsSent

1.3.6.1.2.1.241.1.2.11.1.8

Counter64 (0..18446744073709551615) · packets

The number of packets sent to this peer port from the current port. These counters are discontinuous.

ptpbaseClockPortAssociatePacketsReceived

1.3.6.1.2.1.241.1.2.11.1.9

Counter64 (0..18446744073709551615) · packets

The number of packets received from this peer port by the current port. These counters are discontinuous.

ptpbaseClockPortAssociateInErrors

1.3.6.1.2.1.241.1.2.11.1.10

Counter64 (0..18446744073709551615) · packets

This object specifies the input errors associated with the peer port. These counters are discontinuous.

ptpbaseClockPortAssociateOutErrors

1.3.6.1.2.1.241.1.2.11.1.11

Counter64 (0..18446744073709551615) · packets

This object specifies the output errors associated with the peer port. These counters are discontinuous.

↑ To TOC