DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a
Serial number of the hardware.
cnosSysInfoBoardRevision
1.3.6.1.4.1.9.10.43.1.1.2
Integer32 (0..2147483647)
Returns the revision number of the switch main board on which the system firmware resides.
cnosSysInfoBootVersion
1.3.6.1.4.1.9.10.43.1.1.3
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..8) · OCTET STRING · hint 255a
Returns the version number of the switch boot S/W residing in flash. The format is 'V1.2.3'.
cnosSysInfoAddrCapacity
1.3.6.1.4.1.9.10.43.1.1.4
Integer32 (0..2147483647)
The system-wide maximum number of addresses supported.
cnosSysConfigReset
1.3.6.1.4.1.9.10.43.1.2.1
INTEGER1 = noReset2 = reset · Integer32
Setting this object to reset(2) causes a complete reset of both hardware and software, but does not run the POST (Power On Self Test).
Setting this object to noReset(1) has no effect. The switch always returns the value noReset(1) when this object is read.
cnosSysConfigDefaultReset
1.3.6.1.4.1.9.10.43.1.2.2
INTEGER1 = noReset2 = reset · Integer32
Setting this object to reset(2) causes a complete reset of both hardware and software, but does not run the POST (Power On Self Test). All configuration parameters will revert to their factory default settings, and all addresses assigned will be removed.
Setting this object to noReset(1) has no effect. The switch always returns the value noReset(1) when this object is read.
cnosSysConfigMonitor
1.3.6.1.4.1.9.10.43.1.2.3
INTEGER1 = enabled2 = disabled · Integer32
Selects whether frames to/from certain ports are sent to conSwitchSysConfigMonitorPort. A port is selected for monitoring purpose when its cnosPortMonitoring object is set to enabled.
cnosSysConfigMonitorPort
1.3.6.1.4.1.9.10.43.1.2.4
Integer32 (0..8)
Port number to which all frames to/from monitored ports are sent. Frames are only monitored if the sysConfigMonitor object is set to enabled(1).
A number from 1 to 8 selects a switch port. The number 0 selects no monitor port.
Table details
cnosPortTable
1.3.6.1.4.1.9.10.43.1.3.1
Index: ifIndex
A list of configuration entries for individually switched ports. There in one entry created automatically for each switch port (ifType of ethernetCsmacd) on the device.
A unique value for each interface. Its value ranges between 1 and the value of ifNumber. The value for each interface must remain constant at least from one re-initialization of the entity's network management system to the next re- initialization.
cnosPortControllerRevision
1.3.6.1.4.1.9.10.43.1.3.1.1.1
Integer32 (0..2147483647)
Returns the revision number of the port controller.
cnosPortName
1.3.6.1.4.1.9.10.43.1.3.1.1.2
DisplayStringRepresents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..80) · OCTET STRING · hint 255a
A descriptive string of up to 80 characters used by the network administrator to name a port.
Set to fullDuplex(1) to operate in full duplex mode: port will allow simultaneous transmit and receive which can double its bandwidth. Set to halfDuplex(2) to operate in normal mode. Set to autoNegotiate(3) to allow the switch to negotiate with the other end of the connection.
Set to tenMbps(1) to operate in 10Mbps speed mode. Set to oneHundredMbps(2) to operate in 100Mbps speed mode. Set to autoNegotiate(3) to allow the switch to negotiate with the other end of the connection.
cnosPortSpeedStatus
1.3.6.1.4.1.9.10.43.1.3.1.1.6
INTEGER1 = tenMbps2 = oneHundredMbps · Integer32
The operating speed of the switched port.
cnosPortMonitoring
1.3.6.1.4.1.9.10.43.1.3.1.1.7
INTEGER1 = enabled2 = disabled · Integer32
Set to enabled(1) to forward receive and transmit frames on this port to the port identified by cnosSysConfigMonitorPort. Set to disabled(2) to not monitor frame traffic on this port.
cnosPortLinkStatus
1.3.6.1.4.1.9.10.43.1.3.1.1.8
INTEGER1 = link2 = noLink · Integer32
The current port link status.
cnosPortSTPPortFastMode
1.3.6.1.4.1.9.10.43.1.3.1.1.9
INTEGER1 = enabled2 = disabled · Integer32
This object configures the port into the Spanning Tree port-fast mode. When enabled(1), the STP can transition the port's state directly from blocking to forwarding, and vice versa, without going through the intermediate listening and learning states.
This object should only be enabled for a port that is connected to a single workstation. A port that is attached to a network segment with multiple network nodes or bridges should have this object set to disabled(2) since a temporary loop may occur when port changes state.
Set the port to be a member of a specified VLAN. Set the port to all(5) to be shared among all VLANs.
cnosVlanTable
1.3.6.1.4.1.9.10.43.1.4.1
Index: cnosVlanIndex
Table containing a list of VLANs.
cnosVlanIndex
1.3.6.1.4.1.9.10.43.1.4.1.1.1
Integer32 (1..4)
Identification of a VLAN entry.
cnosVlanSTPState
1.3.6.1.4.1.9.10.43.1.4.1.1.2
INTEGER1 = enabled2 = disabled · Integer32
The switch implements the 802.1d Spanning Tree Algorithm & Protocol (STP) on all its port to detect loops in the bridge topology. The user may, for any reason, elect to disable the execution of STP, by setting this object to disabled(2).