EZ5 MIB Catalog

DLINKES-POE-MIB

2020-11-30

Download DLINKES-POE-MIB.txt Open DLINKES-POE-MIB.txt in a new tab

A MIB module for extending POWER-ETHERNET-MIB specified in RFC 3621.

TABLES (7) · TRAPS (4)

Tables (7)

NameOID
esPoeGroupCfgTable1.3.6.1.4.1.171.17.24.1.1
esPoeGroupInfoTable1.3.6.1.4.1.171.17.24.1.2
esPoeIfCfgTable1.3.6.1.4.1.171.17.24.1.3.1
esPoeIfStatusTable1.3.6.1.4.1.171.17.24.1.3.2.1
esPoeIfMeasurementTable1.3.6.1.4.1.171.17.24.1.3.2.2
esPoeIfStatisticsTable1.3.6.1.4.1.171.17.24.1.3.2.3
esPoeIfPdAliveCfgTable1.3.6.1.4.1.171.17.24.1.3.3

Traps (4)

NameOID
esPoeIfPowerDeniedNotification1.3.6.1.4.1.171.17.24.0.1
esPoeIfPowerOverLoadNotification1.3.6.1.4.1.171.17.24.0.2
esPoeIfPowerShortCircuitNotification1.3.6.1.4.1.171.17.24.0.3
esPoeIfPdAliveFailOccurNotification1.3.6.1.4.1.171.17.24.0.4

END OF TOC

Table details

esPoeGroupCfgTable

1.3.6.1.4.1.171.17.24.1.1

Index: pethMainPseGroupIndex

This table consists of a list of group configurations for PoE. Group means box in the stack or module in a rack. For non-modular devices, the pethMainPseGroupIndex is 1.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

esPoeGroupPolicyPreempt

1.3.6.1.4.1.171.17.24.1.1.1.1

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object configures whether to disconnect the PD which is powered with lower priority in order to release the power to the new connected PD with higher priority under power shortage condition. If this object is 'false', then the policy is first in first serviced. Thus the new PD will not be serviced if the power budget is running out. If this object is 'true', then the power provisioned to PD with lower priority can be preempted to release the power to the new connected PD with higher priority.

esPoeGroupClearIfStatistic

1.3.6.1.4.1.171.17.24.1.1.1.2

PortListEach octet within this value specifies a set of eight ports, with the first octet specifying ports 1 through 8, the second octet specifying ports 9 through 16, etc. Within each octet, the most significant bit represents the lowest numbered port, and the least significant bit represents the highest numbered port. Thus, each port of the bridge is represented by a single bit within the value of this object. If that bit has a value of '1', then that port is included in the set of ports; the port is not included if its bit has a value of '0'. · OCTET STRING

This object is used to clear the PoE statistics of pethPsePortEntry for specified ports.

esPoeGroupGuardBand

1.3.6.1.4.1.171.17.24.1.1.1.3

Unsigned32 · milliwatts

Configures the amount of power to be preserved for guard band protection. The PoE guard-band can provide protection PoE enabled ports from being powered off and then ON when there is a sudden spike in the consumed power of PDs. The specified amount of guard band power is preserved to provide the regulation during sudden spike in the consumed power of PDs.

esPoeGroupInfoTable

1.3.6.1.4.1.171.17.24.1.2

Index: pethMainPseGroupIndex

This table consists of a list of PoE information for groups.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

esPoeGroupMaxPorts

1.3.6.1.4.1.171.17.24.1.2.1.1

Integer32

This object indicates the maximum number of ports that the group can support.

esPoeGroupHWVersion

1.3.6.1.4.1.171.17.24.1.2.1.2

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object indicates H/W version of PoE chip.

esPoeGroupSWVersion

1.3.6.1.4.1.171.17.24.1.2.1.3

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object indicates firmware version of PoE chip.

esPoeIfCfgTable

1.3.6.1.4.1.171.17.24.1.3.1

Index: pethMainPseGroupIndex · pethPsePortIndex

This table consists of a list of PoE configuration information for ports.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

pethPsePortIndex

Integer32 (1..2147483647)

This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.

esPoeIfState

1.3.6.1.4.1.171.17.24.1.3.1.1.1

INTEGER1 = auto2 = never3 = static · Integer32

This object indicates the PoE state of the entry. auto(1) - the port will automatically detect the PD and provision power to the PD. The max wattage value which can be provisioned to the port is determined by esPoeIfMaxPower. If esPoeIfMaxPower is unspecified, then the class of the PD auto determines the maximum wattage which can be provisioned. The PD will not be provisioned if it requests more wattage than the max wattage which is determined. never(2) - indicates the port will not supply power to connected PD; static(3) - indicates manager pre-allocate power budget to the port by configuring the esPoeIfMaxPower object. The power budget is allocated to the port even though there is no PD connected to the port. If esPoeIfMaxPower is not configured, default value is 15400mW for 802.3af and 30000mW for 802.3at.

esPoeIfMaxPower

1.3.6.1.4.1.171.17.24.1.3.1.1.2

Integer32 (0 | 1000..30000) · milliwatts

This object indicates the max wattage value which can be provisioned to the port. Note: This object is valid only while the esPoeIfState object is configured as auto or static.

esPoeIfTimeRange

1.3.6.1.4.1.171.17.24.1.3.1.1.3

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..32) · OCTET STRING · hint 255a

This object indicates the name of time-range profile to delineate the activation period. A zero length string indicates the time-range is not specified. Note: This object is valid only while the esPoeIfState is 'auto'.

esPoeIfLegacyPdEnabled

1.3.6.1.4.1.171.17.24.1.3.1.1.4

TruthValue1 = true2 = falseRepresents a boolean value. · Integer32

This object indicates the state of legacy PD support.

esPoeIfStatusTable

1.3.6.1.4.1.171.17.24.1.3.2.1

Index: pethMainPseGroupIndex · pethPsePortIndex

This table consists of a list of PoE status for ports.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

pethPsePortIndex

Integer32 (1..2147483647)

This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.

esPoeIfDetectStatus

1.3.6.1.4.1.171.17.24.1.3.2.1.1.1

INTEGER1 = disabled2 = searching3 = requesting4 = delivering5 = faulty · Integer32

This object indicates the operational status of the port PD detection. disabled(1) - PSE function is disabled. searching(2) - Remote PD is not connected. requesting(3) - Remote PD is inserted, but the PSE doesn't provide power yet. delivering(4) - Remote PD is now powering by PoE system. faulty(5) - Device detection or a powered device is in a faulty state.

esPoeIfFaultyType

1.3.6.1.4.1.171.17.24.1.3.2.1.1.2

INTEGER0 = notApplicable1 = mpsAbsent2 = pdShort3 = overload4 = powerDenied5 = thermalShutdown6 = startupFailure7 = classificationFailure · Integer32

This object indicates the specific faulty type. It is meaningful only when esPoeIfDetectStatus object is 'faulty'. notApplicable(0) - indicates this object is meaningless, e.g. the esPoeIfDetectStatus is not 'faulty'. mpsAbsent(1) - indicates MPS(Maintain Power Signature) Absent pdShort(2) - indicates PD Short overload(3) - indicates Overload powerDenied(4) - indicates Power Denied thermalShutdown(5)- indicates Thermal Shutdown startupFailure(6) - indicates Startup Failure classificationFailure(7) - indicates Classification Failure(IEEE 802.3at)

esPoeIfPowerClassifications

1.3.6.1.4.1.171.17.24.1.3.2.1.1.3

INTEGER0 = none1 = class02 = class13 = class24 = class35 = class4 · Integer32

Classification is a way to tag different terminals on the Power over LAN network according to their power consumption. Devices such as IP telephones, WLAN access points and others, will be classified according to their power requirements. The meaning of the classification labels is defined in the IEEE specification. This variable is valid only while a PD is being powered, that is, while the attribute pethPsePortDetectionStatus is reporting the enumeration deliveringPower.

esPoeIfOperMaxPower

1.3.6.1.4.1.171.17.24.1.3.2.1.1.4

Unsigned32

This object indicates the maximum power of the port.

esPoeIfOperOutputPower

1.3.6.1.4.1.171.17.24.1.3.2.1.1.5

Unsigned32 · milliwatts

This object indicates the output power of the port.

esPoeIfOperDescription

1.3.6.1.4.1.171.17.24.1.3.2.1.1.6

DisplayStringRepresents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of character codes 0-127 (decimal) - the graphics characters (32-126) are interpreted as US ASCII - NUL, LF, CR, BEL, BS, HT, VT and FF have the special meanings specified in RFC 854 - the other 25 codes have no standard interpretation - the sequence 'CR LF' means newline - the sequence 'CR NUL' means carriage-return - an 'LF' not preceded by a 'CR' means moving to the same column on the next line. - the sequence 'CR x' for any x other than LF or NUL is illegal. (Note that this also means that a string may end with either 'CR LF' or 'CR NUL', but not with CR.) Any object defined using this syntax may not exceed 255 characters in length. SIZE (0..255) · OCTET STRING · hint 255a

This object indicates the description for the port.

esPoeIfMeasurementTable

1.3.6.1.4.1.171.17.24.1.3.2.2

Index: pethMainPseGroupIndex · pethPsePortIndex

This table consists of a list of POE measurement information for ports.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

pethPsePortIndex

Integer32 (1..2147483647)

This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.

esPoeIfVoltage

1.3.6.1.4.1.171.17.24.1.3.2.2.1.1

Integer32 · millivolts

This object indicates the voltage of the port in millivolts.

esPoeIfCurrent

1.3.6.1.4.1.171.17.24.1.3.2.2.1.2

Integer32 · milliamperes

This object indicates the current of port in milliamperes.

esPoeIfTemperature

1.3.6.1.4.1.171.17.24.1.3.2.2.1.3

Integer32 · Degree Centigrade

This object indicates the temperature of port in degrees centigrade.

esPoeIfPower

1.3.6.1.4.1.171.17.24.1.3.2.2.1.4

Integer32

This object indicates consumption power of port in milliwatts.

esPoeIfStatisticsTable

1.3.6.1.4.1.171.17.24.1.3.2.3

Index: pethMainPseGroupIndex · pethPsePortIndex

This table consists of a list of POE statistics information for ports.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

pethPsePortIndex

Integer32 (1..2147483647)

This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.

esPoeIfStatMpsAbsent

1.3.6.1.4.1.171.17.24.1.3.2.3.1.1

Integer32

This object indicates the MPS absent counter.

esPoeIfStatOverload

1.3.6.1.4.1.171.17.24.1.3.2.3.1.2

Integer32

This object indicates the overload counter.

esPoeIfStatShort

1.3.6.1.4.1.171.17.24.1.3.2.3.1.3

Integer32

This object indicates the short counter.

esPoeIfStatPowerDenied

1.3.6.1.4.1.171.17.24.1.3.2.3.1.4

Integer32

This object indicates the power denied counter.

esPoeIfStatInvalidSignature

1.3.6.1.4.1.171.17.24.1.3.2.3.1.5

Integer32

This object indicates the invalid signature counter.

esPoeIfPdAliveCfgTable

1.3.6.1.4.1.171.17.24.1.3.3

Index: pethMainPseGroupIndex · pethPsePortIndex

This table consists of a list of configuration for the PD alive check function for ports. The PD alive check feature provides the solution for PD device that has the stop working or no response problem via Ping mechanism. Detailed Process: The detailed processes are described as follows: 1. The system needs to periodically monitor the specific PD by using Ping function. If there is no response, system takes one of the following actions: (1) Reset: Switch resets (disable then enable) PoE power on the port which connects to a PD under monitoring. (2) Notify: Switch sends logs and traps to notify the administrator. (3) Both: Switch sends logs and traps, and resets the PoE port power. 2. The system should implement the retry mechanism to check PD aliveness, hence the system will reset the PoE port power feeding after the retry by using Ping without any response from a PD. 3. If the action is Reset or Both, the system needs to wait for PD recovery from rebooting and then executes the Ping function again. Besides, the waiting time can be configured by users. 4. If PoE schedule (time range) function is configured on the port which enables the PD Alive Check function, the time range function has the top priority, and therefore PD Alive Check function will not work while PoE time range function is still active. 5. This function only takes effect on PoE enabled port with power feeding. Note: It is required to setup IP settings properly that the PD can be reachable for Ping, otherwise this function cannot work as expected. Limitation 1. Support Ping Function: If the PD does not support ICMP, this function cannot work normally. 2. Direct-Connected PD: The Reset Action can only work on the direct-connected PD. If the PD is not connected directly, the Reset Action may not work as expected. 3. PD Also Acts as PSE: If the direct-connected PD is also a PSE, all the next level PDs connect to this PSE will be power cycling whenever PD Alive Check function takes effect on 'Reset' or 'Both' Action.

from POWER-ETHERNET-MIB

pethMainPseGroupIndex

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

pethPsePortIndex

Integer32 (1..2147483647)

This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.

esPoeIfPdAliveCfgState

1.3.6.1.4.1.171.17.24.1.3.3.1.1

INTEGER1 = enabled2 = disabled · Integer32

This object indicates the the PD alive function sate. enabled - Enable the PD alive check function disabled - Disable the PD alive check function.

esPoeIfPdAliveCfgPdIpType

1.3.6.1.4.1.171.17.24.1.3.3.1.2

InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address. unknown(0) An unknown address type. This value MUST be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below. ipv4(1) An IPv4 address as defined by the InetAddressIPv4 textual convention. ipv6(2) An IPv6 address as defined by the InetAddressIPv6 textual convention. ipv4z(3) A non-global IPv4 address including a zone index as defined by the InetAddressIPv4z textual convention. ipv6z(4) A non-global IPv6 address including a zone index as defined by the InetAddressIPv6z textual convention. dns(16) A DNS domain name as defined by the InetAddressDNS textual convention. Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType. To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation. Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32

This object indicates the IP address type of the target PD.

esPoeIfPdAliveCfgPdIpAddr

1.3.6.1.4.1.171.17.24.1.3.3.1.3

InetAddressDenotes a generic Internet address. An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row. The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error. When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING

This object indicates the IP address of the target PD.

esPoeIfPdAliveCfgInterval

1.3.6.1.4.1.171.17.24.1.3.3.1.4

Unsigned32 (10..300) · seconds

This object indicates the time interval for system issues ping request to detect the target PD. The valid range for interval time is 10s to 300s.

esPoeIfPdAliveCfgRetry

1.3.6.1.4.1.171.17.24.1.3.3.1.5

Unsigned32 (0..5) · times

This object indicates the retry count of ping request when PD has no response. The valid range for retry count is 0 to 5 times.

esPoeIfPdAliveCfgWaitTime

1.3.6.1.4.1.171.17.24.1.3.3.1.6

Unsigned32 (30..300) · seconds

This object indicates the waiting time for PD reboot. The valid range for waiting time is 30s to 300s.

esPoeIfPdAliveCfgAction

1.3.6.1.4.1.171.17.24.1.3.3.1.7

INTEGER1 = reset2 = notify3 = both · Integer32

This object indicates the action when PD doesn't reply the ping request. reset- System will reset the PoE port state . notify- System will send log and trap to notify the administrator. both- System will send log and trap first and reset the PoE port state.

esPoeIfPdAliveCfgResidentialVlan

1.3.6.1.4.1.171.17.24.1.3.3.1.8

VlanIdThe VLAN-ID that uniquely identifies a VLAN. This is the 12-bit VLAN-ID used in the VLAN Tag header. The range is defined by the REFERENCEd specification.Reference: IEEE Std 802.1Q 2003 Edition, Virtual Bridged Local Area Networks. (1..4094) · Integer32 · hint d

This object indicates the VLAN identifier (VID) of the source IP interface dedicated for ICMP messages. The specific VID of the IP interface is only used for IPv6 ICMP messages.

Trap details

esPoeIfPowerDeniedNotification

1.3.6.1.4.1.171.17.24.0.1

This Notification indicates if PSE state diagram enters the state POWER_DENIED. At least 500 msec must elapse between notifications being emitted by the same object instance.

pethPsePortPowerDeniedCounter

1.3.6.1.2.1.105.1.1.1.12

Counter32

This counter is incremented when the PSE state diagram enters the state POWER_DENIED.

esPoeIfPowerOverLoadNotification

1.3.6.1.4.1.171.17.24.0.2

This Notification indicates if PSE state diagram enters the state ERROR_DELAY_OVER. At least 500 msec must elapse between notifications being emitted by the same object instance.

pethPsePortOverLoadCounter

1.3.6.1.2.1.105.1.1.1.13

Counter32

This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_OVER.

esPoeIfPowerShortCircuitNotification

1.3.6.1.4.1.171.17.24.0.3

This Notification indicates if PSE state diagram enters the state ERROR_DELAY_SHORT. At least 500 msec must elapse between notifications being emitted by the same object instance.

pethPsePortShortCounter

1.3.6.1.2.1.105.1.1.1.14

Counter32

This counter is incremented when the PSE state diagram enters the state ERROR_DELAY_SHORT.

esPoeIfPdAliveFailOccurNotification

1.3.6.1.4.1.171.17.24.0.4

This Notification indicates if the PD device has the stop working or no response problem.

pethMainPseGroupIndex

1.3.6.1.2.1.105.1.3.1.1.1

Integer32 (1..2147483647)

This variable uniquely identifies the group to which power Ethernet PSE is connected. Group means (box in the stack, module in a rack) and the value 1 MUST be used for non-modular devices. Furthermore, the same value MUST be used in this variable, pethPsePortGroupIndex, and pethNotificationControlGroupIndex to refer to a given box in a stack or module in a rack.

pethPsePortIndex

1.3.6.1.2.1.105.1.1.1.2

Integer32 (1..2147483647)

This variable uniquely identifies the power Ethernet PSE port within group pethPsePortGroupIndex to which the power Ethernet PSE entry is connected.

esPoeIfPdAliveCfgPdIpType

1.3.6.1.4.1.171.17.24.1.3.3.1.2

InetAddressType0 = unknown1 = ipv42 = ipv63 = ipv4z4 = ipv6z16 = dnsA value that represents a type of Internet address. unknown(0) An unknown address type. This value MUST be used if the value of the corresponding InetAddress object is a zero-length string. It may also be used to indicate an IP address that is not in one of the formats defined below. ipv4(1) An IPv4 address as defined by the InetAddressIPv4 textual convention. ipv6(2) An IPv6 address as defined by the InetAddressIPv6 textual convention. ipv4z(3) A non-global IPv4 address including a zone index as defined by the InetAddressIPv4z textual convention. ipv6z(4) A non-global IPv6 address including a zone index as defined by the InetAddressIPv6z textual convention. dns(16) A DNS domain name as defined by the InetAddressDNS textual convention. Each definition of a concrete InetAddressType value must be accompanied by a definition of a textual convention for use with that InetAddressType. To support future extensions, the InetAddressType textual convention SHOULD NOT be sub-typed in object type definitions. It MAY be sub-typed in compliance statements in order to require only a subset of these address types for a compliant implementation. Implementations must ensure that InetAddressType objects and any dependent objects (e.g., InetAddress objects) are consistent. An inconsistentValue error must be generated if an attempt to change an InetAddressType object would, for example, lead to an undefined InetAddress value. In particular, InetAddressType/InetAddress pairs must be changed together if the address type changes (e.g., from ipv6(2) to ipv4(1)). · Integer32

This object indicates the IP address type of the target PD.

esPoeIfPdAliveCfgPdIpAddr

1.3.6.1.4.1.171.17.24.1.3.3.1.3

InetAddressDenotes a generic Internet address. An InetAddress value is always interpreted within the context of an InetAddressType value. Every usage of the InetAddress textual convention is required to specify the InetAddressType object that provides the context. It is suggested that the InetAddressType object be logically registered before the object(s) that use the InetAddress textual convention, if they appear in the same logical row. The value of an InetAddress object must always be consistent with the value of the associated InetAddressType object. Attempts to set an InetAddress object to a value inconsistent with the associated InetAddressType must fail with an inconsistentValue error. When this textual convention is used as the syntax of an index object, there may be issues with the limit of 128 sub-identifiers specified in SMIv2, STD 58. In this case, the object definition MUST include a 'SIZE' clause to limit the number of potential instance sub-identifiers; otherwise the applicable constraints MUST be stated in the appropriate conceptual row DESCRIPTION clauses, or in the surrounding documentation if there is no single DESCRIPTION clause that is appropriate. SIZE (0..255) · OCTET STRING

This object indicates the IP address of the target PD.

↑ To TOC